• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 69
  • 54
  • 10
  • 9
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 158
  • 158
  • 65
  • 54
  • 54
  • 27
  • 27
  • 24
  • 23
  • 22
  • 21
  • 18
  • 18
  • 18
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Flavona e análogos como radioligantes para imageamento cerebral. Síntese, marcação com radioiodo e estudos in vivo frente a sítios receptores benzodiazepínicos / Flavone and analogs as radioligands for brain imaging synthesis, radioiodine labeling and in vivo studies against benzodiazepine receptor sites

Grallert, Sibila Roberta Marques 12 December 2006 (has links)
O desenvolvimento de radioligantes para o sistema nervoso central (SNC) com características radiotraçadoras que justifiquem seu uso em diagnóstico por geração de imagens é esperado pela comunidade médica nuclear. Os benzodiazepínicos flumazenil-11C e iomazenil-123I são utilizados, com limitações, para investigações clínicas de densidade de sítios receptores benzodiazepínicos no cérebro em patologias como Alzheimer, epilepsia e depressão, entre outras. No Brasil, entretanto, estes traçadores ainda não estão disponíveis para uso clínico. Neste sentido, os flavonóides têm despertado interesses como perspectiva de nova classe de compostos com atividade no SNC podendo originar radiotraçadores com perspectivas para aplicação em imageamento cerebral. Baseado no exposto, a proposta deste estudo envolve o planejamento, a síntese e a marcação com radioiodo (131I e 123I) de flavona e análogos, o controle de qualidade radioquímico, os estudos de biodistribuição e o imageamento, para a avaliação do perfil de captação desses compostos e potencial aplicação em estudos cerebrais, frente a sítios receptores benzodiazepínicos. Os compostos estudados neste trabalho foram obtidos empregando-se a transformação de Baker-Venkataraman. A flavona e análogos foram identificados através de espectros de RMN-1H, RMN-13C e IV. O grau de pureza das substâncias obtidas foi confirmado através da medição da faixa de fusão. Os compostos radiomarcados foram obtidos com alta pureza radioquímica por substituição eletrofílica aromática direta. Esta marcação propiciou estabilidade in vitro após 24 horas e, para a flavona radiomarcada estabilidade in vivo, uma vez que a tireóide não apresentou captação significativa em tempos menores que 1 hora e excreção favorável no tempo de 24 horas. Os estudos de biodistribuição foram realizados em camundongos Swiss, verificando-se alta concentração de flavona-iodo-131 no cérebro, principalmente até 30 minutos após a injeção intravenosa e eliminação favorável após 24 horas de estudo. As imagens cerebrais foram realizadas em coelho New Zeland e em ratos Wistar adquiridas em gama câmara analógica sugerindo que a captação desse ligante no cérebro em tempos curtos, até 30 minutos, viabiliza a aquisição de imagens cintilográficas. Adicionalmente, foram desenvolvidos estudos de modelagem molecular da flavona e da flavona radiomarcada, utilizando-se mecânica quântica AM1 semi-empírico, corroborando a reatividade química desse composto frente à marcação com radioiodo por substituição eletrofílica, processo controlado predominantemente por interações eletrostáticas. Foram calculados os valores individuais de cargas para cada carbono da estrutura da flavona, incluindo cargas de Mulliken, Natural e Eletrostática, e foram gerados os mapas topográficos de distribuição de cargas de ambas as moléculas, evidenciando que as posições 6 e 8, na molécula de flavona, são as mais prováveis para a substituição por radioiodo. / The development of radioligands for the Central Nervous System (CNS) with adequate radiotracer characteristics for the use in imaging diagnostic has been long expected by the medical community. Benzodiazepines flumazenil-11C and iomazenil-123I are employed with limitations in clinical investigations of the density of receptor sites in the brain in pathologies such as Alzheimer, epilepsy, and depression. Nevertheless, in Brazil these radiotracers are not available in market, yet. In this respect, flavonoids has drawing attention as a perspective of a new class of compounds wit CNS activity and potential of originating radiotracers to be employed in brain imaging. Therefore, the goal of this work consisted in the planning, synthesis, and labeling with radioiodine (131I and 123I) of flavone and analogs, as well as to perform radiochemical quality control, biodistribuction, and imaging studies of the radiotracers obtained in order to evaluate the uptake profile and potential for use in cerebral studies of benzodiazepinic receptors sites. To obtain the compounds, we utilized the Baker-Venkataraman transformation, and NMR-1H, NMR-13C, and IR spectroscopy were employed for identification of the molecules. The purity of the compounds obtained was assessed by means of melting point determinations. The radiolabeled compounds were obtained by aromatic electrophilic substitution with a high degree of radiochemical purity. The labeling allowed in vitro stability after 24 hours and in vivo stability of the radiolabeled flavone, provided that the thyroid did not presented significant uptake in less than one hour and favorable excretion in 24 hours. Biodistribution studies were carried out employing Swiss mice. The results indicated high concentrations of flavone-I131 in the brain, especially in the first 30 minutes after intravenous injection, as well as favorable elimination after 24 hours. Brain images were obtained from New Zeland rabbit and Wistar rats in analogical gamma camera, suggesting that short-time brain uptake of the radioligand (up to 30 minutes) allows the acquisition of cynthilographic images. Additionally, molecular modeling studies of the flavone were performed employing the semi-empiric method of AM1. The results corroborate the chemical reactivity of the compound for labeling with radioiodine by aromatic electrophilic substitution, process that is governed mainly by electrostatic interactions. The individual values of Mulliken, Natural, and Electrostatic charges of each carbon atom in flavone structure were calculated and topographic maps of charge distribution were then generated. The analysis of the maps indicates that positions 6 and 8 in the flavone molecule are most likely to present the radioiodine substitution.
122

Análise dos fatores de risco para peritonite bacteriana espontânea em pacientes cirróticos e do perfil da flora infectante com o uso de antibióticos profiláticos / Analysis of risk factors for spontaneous bacterial peritonitis in cirrhotic patients and the ascitic fluid microbiology with use of prophylactic antibiotics

Sposeto, Valdinélia Bomfim Barban 28 May 2009 (has links)
INTRODUÇÃO: A realização de procedimentos invasivos e o comprometimento da função hepática têm sido apontados como importantes fatores predisponentes à peritonite bacteriana primária (PBE) em pacientes cirróticos. Apesar das bactérias gram-negativas ainda serem os agentes mais freqüentemente isolados, a incidência de infecção por bactérias gram positivas tem aumentado. OBJETIVOS: Analisar os fatores de risco para PBE em pacientes cirróticos e relacionar o perfil da flora infectante do líquido ascítico com o uso de antibióticos. MÉTODOS: Estudo retrospectivo de resultados de 1.114 paracenteses realizadas em 348 pacientes no período de 2005 a 2007 no Departamento de Gastroenterologia do Hospital das Clínicas da Universidade de São Paulo. Foram definidos dois grupos: com e sem PBE, segundo resultado da leucometria do líquido ascítico. Os seguintes fatores foram analisados: aspartato aminotransferase (AST); alanina aminotransferase (ALT); bilirrubinas totais; INR; creatinina; uso do propranolol e sua resposta hemodinâmica; antecedente de hemorragia digestiva alta; choque hipovolêmico; tratamento endoscópico de varizes de esôfago; sondagem vesical; cateteres intravenosos; gravidade da doença hepática (escores de Child-Pugh, MELD e MELD-Na); infecções associadas e o perfil da flora infectante, segundo o uso de antibióticos. RESULTADOS: 852 paracenteses em 303 pacientes foram incluídas. A etiologia mais freqüente da cirrose hepática foi hepatite crônica C (25,4%), seguida por álcool (24,1%). O diagnóstico de PBE foi estabelecido em 82 (9,6%) paracenteses, 27 (33%) da forma clássica e 55 (67%) com cultura negativa. No grupo com PBE, observamos níveis mais elevados de bilirrubinas totais e INR (p<0,0001 e p= 0,0016, respectivamente). Não houve diferença entre os grupos, quanto ao uso de betabloqueadores e risco de PBE (32,9% versus 37,3%, p=0,533) e a resposta hemodinâmica ao propranolol (68,2% versus 70%, p=1,00), assim como em relação às seguintes variáveis: hemorragia digestiva alta (6,1% versus 2,5%, p=0,074), escleroterapia endoscópica (2,4% versus 0,8%, p=0,178), sondagem vesical (4,9% versus 2,3%, p=0,138), cateterismo venoso (2,4% versus 1,7%, p= 0,649). O grupo com PBE apresentou maior percentual de pacientes Child C, 51% versus 37%, (p=0,022) e maior frequência de choque hipovolêmico 2,5% versus 0,3% (p=0,0484). Não houve diferença quanto às infecções associadas (p=1,00). No grupo com PBE, as bactérias gram-positivas foram isoladas em 55,6% e as gram-negativas em 44,4% (p=0,3848). Não houve relação entre a presença de infecção por gram positivos e o uso de quinolonas (p=1,00). O aumento de um ponto no escore MELD aumentou o risco de infecção em 1,059 vezes [IC 95% : 1,0266; 1,0930] ou 6%. Não houve diferença no risco de PBE quando analisamos faixas de valores do MELD. O aumento de um ponto no MELD-Na aumentou o risco de infecção em 1,0283 vezes [IC 95%: 1,0073; 1,0497] ou 2,8%. Entretanto, o aumento de um ponto de MELD-Na na faixa entre 6 e 15 aumentou a probabilidade de infecção em 1,3371vezes [IC 95%: 1,0230; 1,7476], entre 16 e 24 aumentou em 3,2371 vezes [IC 95%: 0,1958; 53,5291] e acima de 24 pontos em 14,2663 vezes [IC 95%: 1,2441; 163,5990]. CONCLUSÕES: Pacientes com PBE apresentaram níveis mais elevados das bilirrubinas e de INR, maior frequência de choque hipovolêmico e maior gravidade da cirrose hepática, avaliada pelos escores Child-Pugh, MELD e MELD-Na, sendo o declínio da função hepática, o principal fator de risco para desenvolvimento de PBE. O uso de betabloqueadores e a resposta hemodinâmica ao propranolol não foram associados à proteção contra PBE. O MELD-Na discriminou o risco de infecção em faixas de pontuação e de gravidade. Não houve diferença significante na frequência de infecção por bactérias gram positivas e gram negativas nos pacientes com PBE. Não observamos relação entre a frequência de infecção por gram positivos e uso de quinolonas / INTRODUCTION: Invasive procedures and the decline of the liver function have been considered predisposing factors for spontaneous bacterial peritonitis (SBP) in cirrhotic patients. In spite of the predominance of gram negative, the incidence of gram positive agents is increasing in literature. OBJETIVES: To analyze the risk factors for SBP in cirrhotic patients and to assess if there is increase in the frequency of infection by gram positive agents, according to the use of antibiotics. METHODS: In this retrospective study, the results of 1.114 paracentesis carried out in 348 patients from 2005 to 2007 in the Department of Gastroenterology of the University of São Paulo were enrolled. According to the result of ascitic fluid leucometry, two groups were formed: with and without SBP. The following factors were assessed: aspartate aminotransferase; alanine aminotransferase; bilirubin; INR; creatinine; use of propranolol and hemodynamic response; previous gastrointestinal hemorrhage; hypovolemic shock; endoscopic therapy of esophageal varices; vesical catheter, indwelling vascular catheter, severity of the underlying liver disease (scores Child-Pugh, MELD and MELD-Na); concurrent bacterial infections and the frequency of gram positive bacteria according to the use of antibiotics. RESULTS: 852 paracentesis performed in 303 patients were included. The most prevalent etiology of cirrhosis was hepatitis C virus infection (25.4%), followed by alcoholic (24.1%). The diagnosis of SBP was established in 82 (9.6%) paracentesis, 27 (33%) of them were classical SBP and 55 (67%) were negative-culture SBP. In the SBP group, we found higher levels of bilirubin and more enlarged INR (p<0.0001 e p= 0.0016, respectively). There was no difference between the groups regarding the risk of SBP and the use of betablockers (32.9% versus 37.3%, p=0.533) or hemodynamic response to propranolol therapy (68.2% versus 70%, p=1.00). The following parameters did not reach statistical significance: gastrointestinal bleeding (6.1% versus 2.5%, p=0.074), endoscopic sclerotherapy of varices (2.4% versus 0.8%, p=0.78), vesical catheters (4.9% versus 2.3%, p=0.138), vascular catheters (2.4% versus 1.7%, p= 0.649). The SBP group had a higher frequency of Child C status patients, 51% versus 37%, (p=0.022) and higher frequency of hypovolemic shock 2.5% versus 0.3% (p=0.0484). There was no difference in the frequency of SBP in patients with or without concurrent bacterial infections (p=1,00). In the SBP group, gram positive staining bacteria were found in 55.6% and gram negative in 44.4% (p=0.3848). We found no relationship between gram positive bacteria infection and the use of quinolones (p=1.00). Every single point increased in the MELD score increased the risk of SBP in 1.059 times [95% IC: 1.0266; 1.0930] or by 6%. There was no significant difference in the odds ratio for SBP according to the stratification of MELD values. Every single point increased in the MELD-Na increased the risk of infection in 1.0283 times [95% IC: 1.0073; 1.0497] or 2.8%. Nevertheless, every point increased in the MELDNa between 6 and 15 increased the probability of infection in 1.3371 times [95%] IC: 1.0230; 1.7476], between 16 and 24 in 3.2371 times [95% IC: 0.1958; 53.5291] and higher than 24 points in 14.2663 times [95% IC: 1.2441; 163.5990]. CONCLUSIONS: Patients with SBP had higher levels of bilirubin and INR, higher frequency of hypovolemic shock and more severe underlying liver cirrhosis, as assessed by the Child-Pugh score, MELD and MELD-Na, indicating that the decline of the liver function is the main risk factor for developing SBP in cirrhosis. The use of betablockers and the hemodynamic response to propranolol were not associated to protection against developing SBP. The odds ratios for developing SBP increased according to the stratification of MELD-Na values, but not according to MELD stratification. There was no significant difference in the frequency of gram positive and gram negative infections in patients with SBP. The use of quinolones was not associated with increased frequency of gram positive infections in this series .
123

"Análise comparativa das medidas de espessura da camada de fibras nervosas da retina de pacientes com atrofia em banda do nervo óptico e de indivíduos normais através da tomografia de coerência óptica e da polarimetria a laser" / A comparative analysis of the retinal nerve fiber layer thickness measurements in patients with band atrophy of the optic nerve and in normal controls using optical coherence tomography and scanning laser polarimetry

Leal, Bruno Campêlo 07 July 2006 (has links)
As afecções que acometem a via óptica anterior podem acarretar perda de fibras das células ganglionares retinianas, gerando alterações na camada de fibras nervosas da retina (CFNR). O objetivo deste trabalho foi o de comparar a capacidade da tomografia de coerência óptica (OCT-1), do OCT 3 (Stratus OCT) e do polarímetro de varredura a laser (GDx) em diferenciar olhos normais de olhos com atrofia em banda do nervo óptico e hemianopsia temporal, assim como, comparar o desempenho de tais tecnologias entre si. Foram estudados 37 indivíduos num total de 46 olhos divididos igualmente em dois grupos. O Stratus OCT, o OCT 1 e o GDx se mostraram capazes de identificar corretamente a redução global (average) da espessura da CFNR dos indivíduos com AB comparados com uma população normal. Observamos uma melhora progressiva das sensibilidades/especificidades e das AROC, com o desempenho melhor do OCT1 sobre o GDx e do Stratus OCT sobre o OCT 1 / Most diseases that affect the optic pathways present clinically with loss of one or more visual functions.When optic pathway injuries involve the anterior visual pathways they may cause loss of the retinal nerve fiber layer (RNFL) and "band atrophy" (BA). The purpose of this study was therefore to compare the ability of the optical coherence tomography (OCT) 1, the OCT 3 (Stratus OCT) and the scanning laser polarimetry (GDx) to differentiate normal eyes from eyes with BA of the optic nerve and temporal hemianopsia. Thirty-seven individuals in a total of 46 eyes divided equally in two groups were studied. Each one of the parameters, except the values from the nasal quadrant measured by the GDx, showed statistically significant difference when we compare normal patients with the BA group. The study also showed a gradual improvement of the sensibilities/specificities and of the AROC, with a better performance of the OCT1 compared to GDx and of the Stratus OCT compared to the OCT 1
124

Comparação de métodos de imagem do disco óptico e da camada de fibras nervosas da retina para o diagnóstico do glaucoma / Comparison of optic disc and retinal nerve fiber layer imaging methods for glaucoma diagnosis

Medeiros, Felipe de Araujo Andrade 02 June 2005 (has links)
Alterações no aspecto do disco óptico e da camada de fibras nervosas da retina (CFN) freqüentemente precedem o aparecimento de defeitos de campo visual no glaucoma, o que faz com que a avaliação destas estruturas seja essencial para o diagnóstico precoce e prevenção da perda visual nesta doença. A polarimetria de varredura a laser (GDx VCC), a oftalmoscopia confocal de varredura a laser (HRT II [Heidelberg Retina Tomograph]) e a tomografia de coerência óptica (Stratus OCT) são tecnologias que permitem a avaliação objetiva e quantitativa do disco óptico e da CFN. No presente estudo, estas tecnologias foram comparadas em sua habilidade para diferenciar pacientes glaucomatosos de indivíduos normais. Pacientes com glaucoma foram selecionados com base na presença de defeitos reprodutíveis de campo visual na perimetria acromática automatizada (glaucoma perimétrico), ou com base na evidência documentada de progressão do dano glaucomatoso ao disco óptico, sem presença de defeitos de campo visual (glaucoma pré-perimétrico). Indivíduos normais apresentaram campos visuais e exame clínico dentro da normalidade. Todos os indivíduos foram submetidos a exames com o GDx VCC, HRT II, Stratus OCT e campo visual dentro de um período de três meses. Diversas medidas foram utilizadas para avaliação da acurácia diagnóstica, incluindo áreas sob as curvas receiver operating characteristic (AROC), sensibilidades para especificidades fixas, e razões de probabilidade. Modelos estatísticos foram utilizados para avaliação da influência da severidade do glaucoma e tamanho do disco óptico na performance diagnóstica dos diferentes instrumentos. Um olho de cada indivíduo foi utilizado para análise. Dos 258 sujeitos inicialmente avaliados, 33 (13%) foram posteriormente excluídos por apresentarem imagens de baixa qualidade em pelo menos um dos aparelhos, restando 225 indivíduos (133 glaucomatosos e 92 normais) para análise. Na comparação entre os parâmetros de cada instrumento com maiores valores de AROC, o parâmetro do GDx VCC, Nerve Fiber Indicator (NFI; AROC = 0,91), e o parâmetro do Stratus OCT, Espessura Média (AROC = 0,90), apresentaram áreas sob as curvas ROC significativamente superiores à do parâmetro do HRT II, função discriminante de Bathija (AROC = 0,84). A severidade do defeito de campo visual exerceu influência significativa sob a acurácia diagnóstica dos três instrumentos, com melhora no poder diagnóstico em casos mais avançados da doença. Para o GDx VCC e Stratus OCT, o aumento no tamanho do disco óptico foi associado à diminuição na sensibilidade para detecção do glaucoma; enquanto que, para o HRT II, diminuição no tamanho do disco óptico foi associada à diminuição na sensibilidade. Razões de probabilidade para resultados anormais nas xxv classificações finais de cada instrumento foram associadas a grandes efeitos de mudança na probabilidade pós-teste em relação à probabilidade préteste, sugerindo que o encontro de um resultado anormal em qualquer um destes testes, durante a avaliação de um paciente com suspeita de glaucoma, tem impacto significativo em aumentar a probabilidade de que a doença esteja presente. Além disso, os resultados obtidos na avaliação de pacientes com glaucoma pré-perimétrico sugerem que todos os três instrumentos sejam capazes de detectar alterações estruturais precoces no glaucoma, antes do aparecimento de defeitos de campo visual na perimetria acromática / Changes in the structural appearance of the optic nerve head (ONH) and retinal nerve fiber layer (RNFL) have been reported to precede the development of visual field loss in glaucoma. Detection of ONH and RNFL damage is therefore crucial for early diagnosis of glaucoma and prevention of functional loss from the disease. Scanning laser polarimetry (GDx VCC), confocal scanning laser ophthalmoscopy (HRT II [Heidelberg Retina Tomograph]) and optical coherence tomography (Stratus OCT) are different technologies capable of providing objective and quantitative information related to these structures. The purpose of the present study was to compare, in a single population, the diagnostic abilities of these technologies in the discrimination of glaucomatous patients from healthy subjects. Glaucoma patients were selected based on the presence of repeatable visual field defects, as identified by standard automated perimetry (perimetric glaucoma), or documented evidence of progressive damage to the optic disc, in the absence of detectable visual field loss (preperimetric glaucoma). Normal subjects had normal visual fields and normal clinical examination. All subjects underwent imaging with the GDx VCC, HRT II and Stratus OCT within a 3-month period. Several measures were used for evaluation of diagnostic accuracy, including the area under the receiver operating characteristic curve (AROC), sensitivities at fixed specifities, and likelihood ratios. Statistical models were used to evaluate the influence of glaucoma severity and optic disc size on the diagnostic performance of the different instruments. One eye of each individual was randomly selected for statistical analysis. From an initial group of 258 eligible subjects, 33 (13%) had images of unacceptable quality, leaving 133 glaucoma patients and 92 healthy subjects for further analysis. In the comparison of the parameters with highest values of AROC from each instrument, the GDx VCC Nerve Fiber Indicator (AROC = 0.91) and the Stratus OCT Average Thickness (AROC = 0.90) perfomed significanlty better than the HRT II Bathija discriminant function (AROC = 0.84). For all instruments, the diagnostic accuracy increased with increasing severity of visual field defects. For the GDx VCC and Stratus OCT parameters, an increase in the size of the optic disc was related to a decrease in the sensitivity for glaucoma detection. An opposite effect was observed with the HRT II: a decrease in the size of the optic disc was related to a decrease in the sensitivity for glaucoma diagnosis. Abnormal results for each of the instruments were associated with strong positive likelihood ratios, indicating a large change from prestest to posttest probability of glaucoma. These results suggest that the finding of an abnormal result in any of these tests, when assessing a patient suspect of having glaucoma, would substantially raise the probability of disease. Results of the evaluation of patients with preperimetric glaucoma also suggest that all three instruments are able to detect early glaucomatous structural damage in the absence of visual field loss
125

Avaliação dos efeitos pulmonares e sistêmicos agudos em resposta à injeção intrapleural de talco de diferentes tamanhos de partículas / Pulmonary and systemic response following intrapleural instillation of talc with different particle size

Figueiredo, Viviane Rossi 16 January 2007 (has links)
Pacientes com comprometimento pleural por neoplasias malignas freqüentemente apresentam derrame pleural recidivante. Nestes casos, a sínfise das membranas pleurais (pleurodese) com a finalidade de evitar o acúmulo de líquido no espaço pleural deve ser considerada. O talco é o agente mais utilizado indicado para essa finalidade. Entretanto, seu uso terapêutico continua controverso devido aos efeitos deletérios que podem advir de sua utilização. O mais grave entre todos é a insuficiência respiratória aguda, que pode evoluir para a síndrome do desconforto respiratório agudo (SDRA). Essa complicação pode estar relacionada com a composição, com o tamanho das partículas de talco e com a resposta inflamatória desencadeada pelas mesmas. O objetivo deste estudo foi avaliar os efeitos pulmonares e sistêmicos em resposta à injeção intrapleural (IIP) de talco de partículas pequenas (TP) e de partículas de tamanhos diversos (TM). Cem coelhos foram submetidos à IIP com talco. Metade dos animais foi injetada com TP (diâmetro médio= 6,41 mm) e outra metade com TM (diâmetro médio= 21,15 mm), que é o talco usado na prática clínica. Quinze coelhos compuseram o grupo controle. Foram avaliados a celularidade, os níveis de desidrogenase lática (DHL), proteína C reativa (PCR), interleucina-8 (IL-8) e fator de crescimento endotelial vascular (VEGF) no sangue e no lavado broncoalveolar (LBA) às 6, 24, 48, 72 e 96 horas após a IIP. Realizou-se também a quantificação de partículas de talco e a análise histológica dos pulmões. Utilizamos o teste t e Anova na análise estatística, considerando p< 0,05 como significância estatística. A maioria dos parâmetros avaliados apresentou níveis mais elevados no sangue e no LBA dos animais injetados com TP ou TM quando comparados ao grupo controle, sugerindo uma resposta sistêmica e pulmonar à IIP de talco. Com relação aos grupos de talco, os níveis de PCR e de IL-8 apresentaram-se mais elevados no sangue e no LBA dos animais injetados com TP. Partículas de talco foram observadas em todas as lâminas examinadas, sem diferenças significativas entre os grupos. Os pulmões dos animais injetados com TP apresentaram infiltrado linfomononuclear mais exuberante que no grupo TM. A resposta inflamatória pulmonar antecedeu (24 h) a resposta sistêmica (48 h), sugerindo que o pulmão é o principal órgão da resposta sistêmica aguda. Estes achados estudo nos permitem concluir que o talco calibrado com partículas maiores deva ser utilizado na prática clínica, objetivando uma pleurodese mais segura. / Talc has been the pleurodesis agent of choice for the local treatment of recurrent pleural diseases. However, serious concerns exist about its safety. The acute respiratory failure is considered its most serious complication. The physiopathologic mechanisms involved are still unclear. It has been attributed to the systemic dissemination of small talc particles, to the composition of talc and to the inflammatory response. The purpose of this study was to evaluate the systemic and pulmonary response following intrapleural instillation of small particles talc (ST) and mixed particles talc (MT). One hundred rabbits received intrapleural instillation of talc as follows: fifty rabbits were instilled with ST (mean diameter=6,41 microns), and 50 rabbits with MT (mean diameter= 21,15 microns). As control (without talc instillation) were used 15 animals. We studied the pulmonary and systemic inflammatory response (total cell count and differential, levels of lactate dehydrogenase (LD), C-reactive protein (PCR), interleukin-8 (IL-8) and human vascular endothelial growth factor (VEGF) in serum and bronchoalveolar lavage (BAL). Histologic analysis of both lungs and quantitation of talc particles were done at 6, 24, 48, 72 and 96h. ST group showed higher pulmonary and systemic inflammatory response than did the MT group. PCR and IL-8 concentrations were higher in serum and BAL of ST group than the MT group. Many talc particles were observed in the pulmonary tissue of both talc groups, but without statistical significance. We also observed a predominance of cellular infiltrates (lymphomononuclear cells) in the lungs of ST group. The pulmonary inflammatory response (increased IL-8 in BAL) was earlier (24h) than the systemic inflammatory response (48 h). These observations suggest that the main organ in the systemic inflammatory acute response is lung. So, we recommend the clinical use of mixed talc without small particles to induce safety pleurodesis.
126

Flavona e análogos como radioligantes para imageamento cerebral. Síntese, marcação com radioiodo e estudos in vivo frente a sítios receptores benzodiazepínicos / Flavone and analogs as radioligands for brain imaging synthesis, radioiodine labeling and in vivo studies against benzodiazepine receptor sites

Sibila Roberta Marques Grallert 12 December 2006 (has links)
O desenvolvimento de radioligantes para o sistema nervoso central (SNC) com características radiotraçadoras que justifiquem seu uso em diagnóstico por geração de imagens é esperado pela comunidade médica nuclear. Os benzodiazepínicos flumazenil-11C e iomazenil-123I são utilizados, com limitações, para investigações clínicas de densidade de sítios receptores benzodiazepínicos no cérebro em patologias como Alzheimer, epilepsia e depressão, entre outras. No Brasil, entretanto, estes traçadores ainda não estão disponíveis para uso clínico. Neste sentido, os flavonóides têm despertado interesses como perspectiva de nova classe de compostos com atividade no SNC podendo originar radiotraçadores com perspectivas para aplicação em imageamento cerebral. Baseado no exposto, a proposta deste estudo envolve o planejamento, a síntese e a marcação com radioiodo (131I e 123I) de flavona e análogos, o controle de qualidade radioquímico, os estudos de biodistribuição e o imageamento, para a avaliação do perfil de captação desses compostos e potencial aplicação em estudos cerebrais, frente a sítios receptores benzodiazepínicos. Os compostos estudados neste trabalho foram obtidos empregando-se a transformação de Baker-Venkataraman. A flavona e análogos foram identificados através de espectros de RMN-1H, RMN-13C e IV. O grau de pureza das substâncias obtidas foi confirmado através da medição da faixa de fusão. Os compostos radiomarcados foram obtidos com alta pureza radioquímica por substituição eletrofílica aromática direta. Esta marcação propiciou estabilidade in vitro após 24 horas e, para a flavona radiomarcada estabilidade in vivo, uma vez que a tireóide não apresentou captação significativa em tempos menores que 1 hora e excreção favorável no tempo de 24 horas. Os estudos de biodistribuição foram realizados em camundongos Swiss, verificando-se alta concentração de flavona-iodo-131 no cérebro, principalmente até 30 minutos após a injeção intravenosa e eliminação favorável após 24 horas de estudo. As imagens cerebrais foram realizadas em coelho New Zeland e em ratos Wistar adquiridas em gama câmara analógica sugerindo que a captação desse ligante no cérebro em tempos curtos, até 30 minutos, viabiliza a aquisição de imagens cintilográficas. Adicionalmente, foram desenvolvidos estudos de modelagem molecular da flavona e da flavona radiomarcada, utilizando-se mecânica quântica AM1 semi-empírico, corroborando a reatividade química desse composto frente à marcação com radioiodo por substituição eletrofílica, processo controlado predominantemente por interações eletrostáticas. Foram calculados os valores individuais de cargas para cada carbono da estrutura da flavona, incluindo cargas de Mulliken, Natural e Eletrostática, e foram gerados os mapas topográficos de distribuição de cargas de ambas as moléculas, evidenciando que as posições 6 e 8, na molécula de flavona, são as mais prováveis para a substituição por radioiodo. / The development of radioligands for the Central Nervous System (CNS) with adequate radiotracer characteristics for the use in imaging diagnostic has been long expected by the medical community. Benzodiazepines flumazenil-11C and iomazenil-123I are employed with limitations in clinical investigations of the density of receptor sites in the brain in pathologies such as Alzheimer, epilepsy, and depression. Nevertheless, in Brazil these radiotracers are not available in market, yet. In this respect, flavonoids has drawing attention as a perspective of a new class of compounds wit CNS activity and potential of originating radiotracers to be employed in brain imaging. Therefore, the goal of this work consisted in the planning, synthesis, and labeling with radioiodine (131I and 123I) of flavone and analogs, as well as to perform radiochemical quality control, biodistribuction, and imaging studies of the radiotracers obtained in order to evaluate the uptake profile and potential for use in cerebral studies of benzodiazepinic receptors sites. To obtain the compounds, we utilized the Baker-Venkataraman transformation, and NMR-1H, NMR-13C, and IR spectroscopy were employed for identification of the molecules. The purity of the compounds obtained was assessed by means of melting point determinations. The radiolabeled compounds were obtained by aromatic electrophilic substitution with a high degree of radiochemical purity. The labeling allowed in vitro stability after 24 hours and in vivo stability of the radiolabeled flavone, provided that the thyroid did not presented significant uptake in less than one hour and favorable excretion in 24 hours. Biodistribution studies were carried out employing Swiss mice. The results indicated high concentrations of flavone-I131 in the brain, especially in the first 30 minutes after intravenous injection, as well as favorable elimination after 24 hours. Brain images were obtained from New Zeland rabbit and Wistar rats in analogical gamma camera, suggesting that short-time brain uptake of the radioligand (up to 30 minutes) allows the acquisition of cynthilographic images. Additionally, molecular modeling studies of the flavone were performed employing the semi-empiric method of AM1. The results corroborate the chemical reactivity of the compound for labeling with radioiodine by aromatic electrophilic substitution, process that is governed mainly by electrostatic interactions. The individual values of Mulliken, Natural, and Electrostatic charges of each carbon atom in flavone structure were calculated and topographic maps of charge distribution were then generated. The analysis of the maps indicates that positions 6 and 8 in the flavone molecule are most likely to present the radioiodine substitution.
127

Valor preditivo da topografia de disco óptico para o desenvolvimento de glaucoma / Predictive value of optic disc topography for the development of glaucoma

Alencar, Luciana Pereira Malta de 18 July 2011 (has links)
Objetivos: Analisar o potencial da oftalmoscopia confocal de varredura a laser, através do Heidelberg Retina Tomograph (HRT), para predizer o risco de progressão em pacientes com suspeita de glaucoma. Comparar os resultados obtidos com o índice de probabilidade de glaucoma (GPS) do HRT aos resultados da análise de regressão de Moorfields (ARM), dos parâmetros morfométricos e da avaliação das fotografias estereoscópicas. Métodos: Uma coorte foi selecionada com 223 pacientes com suspeita de glaucoma, que foram seguidos por um período médio de 64,9 ± 37,3 meses. A suspeita de glaucoma baseou-se na aparência do disco óptico e/ou na pressão intraocular elevada (> 21 mmHg). Todos os participantes apresentavam dois exames de campo visual normais ao entrar no estudo. Conceituou-se progressão como o desenvolvimento de um defeito confirmado de campo visual ou deterioração do disco óptico na avaliação seriada das estereofotografias. A associação entre os resultados do HRT na época do início do acompanhamento e a progressão para glaucoma foi investigada através de modelos de regressão do tipo Cox. Usou-se o C-index para a comparação entre os modelos com os diversos parâmetros do HRT, isolados ou ajustados para os outros já conhecidos fatores de risco para progressão (idade, espessura corneana, pressão intraocular e pattern standard deviation PSD). Resultados: No período do estudo, 46 pacientes (21%) apresentaram progressão. Na análise multivariada, o GPS, a ARM e diversos parâmetros morfométricos foram preditivos para progressão, assim como a avaliação subjetiva das estereofotografias. Cada GPS 0,1 maior foi associado com um aumento de 23% no risco de progressão (C-index de 0,69). Os resultados anormais nas classificações finais do GPS e da ARM foram associados a aumentos de 3 e 2 vezes no risco de progressão, respectivamente (C-indexes de 0,70 e 0,68, respectivamente). O parâmetro com o melhor C-index foi a área seccional tranversa da camada de fibras nervosas (0,72). Uma área 0,3 mm2 menor foi associada a um risco 62% maior de progressão. A comparação do valor preditivo entre os modelos com o GPS e com a avaliação subjetiva das estereofotografias foi similar (C-indexes de 0,69 e 0,68, respectivamente). Conclusão: Nesse estudo observamos que as análises objetivas do disco óptico e da região peripapilar obtidas com o HRT contribuíram na avaliação do risco de progressão em pacientes com suspeita de glaucoma. O GPS mostrou-se tão eficaz quanto os parâmetros morfométricos e a análise de regressão de Moorfields, e a comparação do desempenho dos modelos contendo a avaliação subjetiva das estereofotografias e aqueles contendo a avaliação objetiva pelo GPS não mostrou diferenças significativas / Purpose: To evaluate the ability of baseline confocal scanning laser ophthalmoscopy, using the Heidelberg Retina Tomograph (HRT), in predicting the development of progression in patients suspected of having glaucoma. In addition, the study also aimed to compare the predictive abilities of the glaucoma probability score (GPS) with those of the Moorfields regression analysis (MRA) and stereometric parameters, and to compare the performance of the HRT with that of subjective evaluation of optic disc stereophotographs. Methods: This longitudinal study included a cohort of 223 eyes suspected of having glaucoma, which were followed for an average of 64.9 ± 37.3 months. Included suspects had a suspicious appearance of the optic disc and/or elevated intraocular pressure, but normal visual fields. Progression was defined as the development of either repeatable abnormal visual fields or glaucomatous structural deterioration in the appearance of the optic disc during the study period. The association between baseline HRT parameters and progression was investigated by Cox regression models. The comparison between models with HRT parameters, individually or combined with other known risk factors (age, central corneal thickness, pattern standard deviation and intraocular pressure), performed by comparing their C-indexes. Results: Forty-six (21%) eyes converted during the study period. In multivariable models, the GPS, the MRA, and the stereometric parameters were all predictive of progression. A GPS 0.1 larger was associated with an increase of 23% in the risk of progression (C-index of 0.69). Abnormal final classifications for the GPS or the MRA were associated with a three-fold and two-fold increase in the risk of progression, respectively (with C-indexes of 0.70 and 0.68, respectively). The parameter with the best C-index was the nerve fiber layer cross-sectional area (0.72). An area 0.3 mm2 smaller was associated with a 62% higher risk of an individual progress. The comparison between models with the HRT parameters and those with the subjective stereophotograph evaluation had similar results (C-indexes of 0.69 and 0.68, respectively). Conclusion: In this study, we were able to show that the objective structural assessment of the optic disc and peripapillary area obtained with the HRT was significantly predictive for progression in suspected individuals. The GPS was as predictive as the other HRT parameters, and no significant differences were observed between models with the GPS and those with the subjective assessment of the stereophotographs.
128

Chemokines and 8-isoprostane levels in exhaled breath condensate from adult patients with asthma and chronic obstructive pulmonary disease. / Chemokines & 8-isoprostane levels in exhaled breath condensate from adult patients with asthma and chronic obstructive pulmonary disease

January 2005 (has links)
Lau Yin Kei. / Thesis (M.Phil.)--Chinese University of Hong Kong, 2005. / Includes bibliographical references (leaves 58-79). / Abstracts in English and Chinese. / Acknowledgement --- p.I / Abstract --- p.IV / Abstract in Chinese --- p.VI / Abbreviations --- p.VIII / Introduction --- p.1 / Chapter 1.1 --- Prevalence of COPD and asthma in Hong Kong --- p.1 / Chapter 1.2 --- Players in pathogenesis of COPD --- p.2 / Chapter 1.3 --- Players in pathogenesis of asthma --- p.4 / Chapter 1.4 --- The use of exhaled breath condensate in previous studies --- p.6 / Chapter 1. 5 --- Brief overview of chemokines --- p.8 / Chapter 1.6 --- Objective of this study --- p.12 / Materials and methods --- p.14 / Chapter 2.1 --- Study population --- p.14 / Chapter 2.1.1 --- Patients with COPD and control subjects --- p.14 / Chapter 2.1.2 --- Patients with asthma and control subjects --- p.15 / Chapter 2.2 --- Lung function --- p.15 / Chapter 2.3 --- Dyspnoea score measurement of patients with COPD --- p.16 / Chapter 2.4 --- Classification of patients and asthma severity --- p.16 / Chapter 2.5 --- Skin prick test and blood tests --- p.16 / Chapter 2.6 --- Collection of exhaled breath condensate --- p.17 / Chapter 2.7 --- Measurement of constituent in EBC --- p.17 / Chapter 2.7.1 --- "Measurement of 8-isoprostane, MCP-1 and GROα in patients with COPD and the corresponding control subjects" --- p.17 / Chapter 2.7.2 --- Measurement of eotaxin and MDC of patients with asthma and the corresponding control subjects --- p.18 / Chapter 2.8 --- Reproducibility of exhaled breath constituent --- p.18 / Chapter 2.8.1 --- "Assessment of reproducibility of the exhaled MCP-1, GROα and8- isoprostane measurements" --- p.19 / Chapter 2.8.2 --- Assessment of reproducibility of the exhaled eotaxin and MDC measurement --- p.19 / Chapter 2.9 --- Statistical analysis --- p.19 / Results --- p.21 / Chapter 3.1 --- Patients with COPD and corresponding control subjects --- p.21 / Chapter 3.2 --- Patients with asthma and corresponding control subjects --- p.28 / Discussion --- p.36 / Chapter 4.1 --- "Exhaled 8-isoprostane, GRO-α and MCP-1 of patients with COPD and corresponding control subjects" --- p.36 / Chapter 4.2 --- Exhaled eotaxin and MDC from patients with asthma and corresponding control subjects --- p.43 / Chapter 4.3 --- Technical aspects of EBC assessment --- p.49 / Future prospect --- p.54 / Conclusion --- p.56 / References --- p.58 / Tables and Figures / Table 1. Demographics of the COPD and control subjects --- p.22 / Figure 1. The level of 8-isoprostane in the exhaled breath condensate of COPD and control subjects --- p.23 / Figure 2. The level of GROa in the exhaled breath condensate of COPD and control subjects --- p.25 / "Figure 3 Bland and Altman's Plot of the repeatability of 8-isoprostane, GROa and MCP-1 in the exhaled breath condensate of normal controls" --- p.27 / Table2. Clinical and physiological details of the subjects --- p.29 / Figure 4. Level of eotaxin in exhaled breath condensate of asthma and control subjects --- p.30 / Figure 5 Level of MDC in exhaled breath condensate of asthma and control subjects --- p.31 / Table 3. Levels of eotaxin and MDC in exhaled breath condensate of asthma subjects on different dose of inhaled corticosteroids --- p.33 / Figure 6. Relationship between exhaled breath condensate level of MDC and total serum IgE level --- p.35
129

Serum high-sensitivity C-reactive protein concentration of Chinese chronic-renal-failure patients with atherosclerotic vascular disease or cardiac valve calcification.

January 2002 (has links)
Chan Fat-Yiu. / Thesis (M.Sc.)--Chinese University of Hong Kong, 2002. / Includes bibliographical references (leaves 85-93). / Abstracts in English and Chinese. / ACKNOWLEDGEMENTS --- p.4 / SUMMARY --- p.5 / ABBREVIATIONS --- p.9 / LIST OF TABLES --- p.11 / LIST OF FIGURES --- p.13 / Chapter CHAPTER I --- INTRODUCTION --- p.14 / Chapter 1.1 --- The Historical Aspects of C-Reaction Protein --- p.15 / Chapter 1.2 --- Biochemistry of CRP --- p.16 / Chapter 1.3 --- Physiology of CRP --- p.18 / Chapter 1.4 --- Current Clinical Applications of Serum CRP Assay --- p.19 / Chapter 1.5 --- Recent Findings of CRP --- p.21 / Chapter 1.5.1 --- Pathophysiology of atherosclerosis --- p.22 / Chapter 1.5.2 --- A nother atherogenic risk factor: hs- CRP --- p.26 / Chapter 1.5.3 --- Can hs-CRP replace other risk factors? --- p.30 / Chapter 1.5.4 --- Altering hs-CRP result in medication --- p.32 / Chapter 1.6 --- Methods of Measurement of CRP Concentration --- p.33 / Chapter 1.7 --- Analytical Considerations in the Measurement of hs-CRP --- p.34 / Chapter CHAPTER II --- OBJECTIVES AND SIGNIFICANCE --- p.36 / Chapter 2.1 --- Objectives --- p.37 / Chapter 2.2 --- Issues and Problems --- p.37 / Chapter 2.3 --- Significance and Value of this Study --- p.38 / Chapter CHAPTER III --- MA TERIALS AND METHODS I Setting up the serum hs-CRP assay on the Hitachi 911 Analyzer --- p.39 / Chapter 3.1 --- Materials --- p.40 / Chapter 3.1.1 --- Reagents from Roche Diagnostics --- p.40 / Chapter 3.1.2 --- Reagents for the Beckman Coulter Array ® Analyzer --- p.40 / Chapter 3.1.3 --- In-house reagents --- p.41 / Chapter 3.2. --- Apparatus and Equipment --- p.41 / Chapter 3.2.1 --- Hitachi 911 Analyzer --- p.41 / Chapter 3.2.2 --- Beckman Coulter Array ® 360 Analyzer --- p.42 / Chapter 3.3 --- The Tina-quant a C-Reactive Protein (Latex) Ultrasensitive Assay --- p.42 / Chapter 3.3.1 --- Priniciple of the Dual-Radius Enhanced Latex (DuREL´ёØ) technology --- p.42 / Chapter 3.3.2 --- Assessment of Analytical Performance --- p.45 / Chapter CHAPTER IV --- MA TERIALS AND METHODS II Serum hs-CRP in Chinese chronic-renal-failure patients with atherosclerotic vascular disease or cardiac valve calcification --- p.48 / Chapter 4.1 --- Patient Recruitment --- p.49 / Chapter 4.2. --- Blood Specimens --- p.49 / Chapter 4.3 --- Assay Methods --- p.50 / Chapter 4.3.1 --- hs-CRP --- p.50 / Chapter 4.3.2 --- TC --- p.50 / Chapter 4.3.3 --- TG --- p.51 / Chapter 4.3.4 --- HDL-C --- p.51 / Chapter 4.3.5 --- LDL-C --- p.52 / Chapter 4.3.6 --- Apo A-1 --- p.52 / Chapter 4.3.7 --- Apo B --- p.53 / Chapter 4.3.8 --- Lp(a) --- p.53 / Chapter 4.4 --- Ultrasound measurement of carotid artery inter-media thickness --- p.53 / Chapter 4.5 --- Statistical analysis --- p.54 / Chapter CHAPTER V --- RESUTLSI Setting up the serum hs-CRP assay on the Hitachi 911 Analyzer --- p.55 / Chapter 5.1 --- Imprecision --- p.56 / Chapter 5.2 --- Linearity --- p.56 / Chapter 5.3 --- Recovery --- p.56 / Chapter 5.4 --- Detection Limit --- p.57 / Chapter 5.5 --- Carry-over --- p.57 / Chapter CHAPTER VI --- RESULTS II Serum hs-CRP in Chinese chronic-renal-failure patients with atherosclerotic vascular disease or cardiac valve calcification --- p.63 / Chapter 6.1 --- Patient Recruitment --- p.64 / Chapter 6.2 --- Chinese chronic-renal-failure patients with AVD --- p.64 / Chapter 6.3 --- Chinese chronic-renal-failure patients with CVC --- p.65 / Chapter CHAPTER VII --- DISCUSSION I Performance of the serum hs-CRP assay on the Hitachi 911 Analyzer --- p.75 / Chapter 7.1 --- "Imprecision, Detection Limit, Linearity, and Recovery of hs-CRP Assay" --- p.76 / Chapter 7.1.1 --- Imprecision --- p.76 / Chapter 7.1.2 --- Detection Limit --- p.76 / Chapter 7.1.3 --- Linearity --- p.76 / Chapter 7.1.4 --- Recovery --- p.77 / Chapter 7.2 --- Overall Performance --- p.77 / Chapter CHAPTER VIII --- DISCUSSION II Serum hs-CRP in Chinese chronic-renal-failure patients with atherosclerotic vascular disease or cardiac valve calcification --- p.79 / Chapter 8.1 --- CAPD Patients --- p.80 / Chapter 8.2 --- Serum hs-CRP Concentration of AVD and CVC Patients --- p.81 / Chapter 8.3 --- Other risk factors in AVD and CVC Patients --- p.82 / Chapter 8.4 --- Conclusion --- p.83 / REFERENCES --- p.85
130

Comparação entre diversas técnicas de imagem para diagnóstico do glaucoma / Comparison of different imaging techniques to diagnose glaucoma

Vessani, Roberto Murad 20 March 2008 (has links)
O objetivo desse estudo foi comparar a habilidade da avaliação subjetiva do disco óptico e da camada de fibras nervosas (CFN) por oftalmologistas generalistas e por um glaucomatólogo com medidas objetivas pela tomografia de coerência óptica (Stratus OCT), oftalmoscopia confocal de varredura a laser (HRTIII), e a polarimetria de varredura a laser (GDxECC) para discriminar olhos glaucomatosos de olhos normais. 61 olhos glaucomatosos e 57 olhos normais de 118 indivíduos foram incluídos nesse estudo. Três oftalmologistas generalistas independentes e um glaucomatólogo avaliaram fotografias estereoscópicas do disco óptico. Curvas ROC (Receiver Operator Characteristic) foram construídas para cada técnica de imagem e a sensibilidade a uma especificidade fixa foi determinada. Comparações das áreas sob essas curvas (AROC) e a concordância (k) foram determinadas entre a graduação das fotografias estereoscópicas e o melhor parâmetro de cada exame de imagem computadorizado. O melhor parâmetro de cada técnica de imagem computadorizada (CFN temporal inferior do Stratus OCT = 0,92; área integrada vertical da topografia do disco óptico pelo Stratus OCT = 0,86; espessura macular do setor inferior externo fornecido pelo Stratus OCT = 0,82; NFI do GDxECC = 0,91; razão área E/D do HRT3 = 0,83) mostrou AROC maior do que a graduação das fotografias estereoscópicas por oftalmologistas generalistas (0,80) para separar olhos glaucomatosos de olhos normais. A graduação por glaucomatólogo forneceu AROC igual ou maior (0,92) do que o melhor parâmetro de exame computadorizado de imagem. A avaliação das fotografias estereoscópicas por glaucomatólogo mostrou melhor concordância com o melhor parâmetro de cada técnica de imagem quantitativa na classificação de olhos como glaucomatosos ou normais comparadas à avaliação de fotografias estereoscópicas por oftalmologistas generalistas. A combinação da avaliação subjetiva do disco óptico por oftalmologistas generalistas com parâmetros objetivos da CFN melhorou a identificação de olhos com glaucoma em uma proporção maior do que a combinação desses parâmetros objetivos com a avaliação do disco óptico por um glaucomatólogo (29,5% versus 19,7%, respectivamente). Os resultados sugerem que a habilidade diagnóstica de todos os exames de imagem computadorizados estudados mostrou melhor desempenho que a avaliação subjetiva do disco óptico por oftalmologistas generalistas, mas não por um glaucomatólogo. Medidas objetivas da CFN podem permitir um aperfeiçoamento na detecção de glaucoma quando combinados com a avaliação subjetiva do disco óptico por oftalmologistas generalistas ou por um glaucomatólogo. / The purpose of this study was to compare the ability of subjective assessment of optic nerve head and retinal nerve fiber layer by general ophthalmologists and by a glaucoma expert with objective measurements by optical coherence tomography (Stratus OCT, Carl Zeiss Meditec, Inc.), confocal scanning laser ophthalmoscope (HRT III; Heidelberg Engineering, Heidelberg, Germany), and scanning laser polarimetry (GDx ECC; Carl Zeiss Meditec, Inc., Dublin, CA) in discriminating glaucomatous and normal eyes. 61 glaucomatous and 57 normal eyes of 118 subjects were included in the study. Three independent general ophthalmologists and one glaucoma expert evaluated ONH stereophotographs. Receiver operating characteristic curves were constructed for each imaging technique and sensitivity at fixed specificity was estimated. Comparisons of areas under these curves (aROC) and agreement (k) were determined between stereophoto grading and best parameter from each technique. Best parameter from each technique showed larger aROC (StratusOCT RNFL = 0.92; StratusOCT ONH vertical integrated area = 0.86; StratusOCT macular thickness = 0.82; GDxECC = 0.91; HRT3 global cup-to-disc area ratio = 0.83) compared to stereophotograph grading by general ophthalmologists (0.80) in separating glaucomatous and normal eyes. Glaucoma expert stereophoto grading provided equal or larger aROC (0.92) than best parameter of each computerized imaging device. Stereophoto evaluated by a glaucoma expert showed better agreement with best parameter of each quantitative imaging technique in classifying eyes either as glaucomatous or normal compared to stereophoto grading by general ophthalmologists. The combination of subjective assessment of the optic disc by general ophthalmologists with RNFL objective parameters improved identification of glaucoma patients in a larger proportion than the combination of these objective parameters with subjective assessment of the optic disc by a glaucoma expert (29.5% versus 19.7%, respectively). The results suggests that the diagnostic ability of all imaging techniques showed better performance than subjective assessment of the ONH by general ophthalmologists, but not by a glaucoma expert. Objective RNFL measurements may provide improvement in glaucoma detection when combined with subjective assessment of the optic disc by general ophthalmologists or by a glaucoma expert.

Page generated in 0.1673 seconds