• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 482
  • 19
  • 9
  • 1
  • Tagged with
  • 513
  • 381
  • 135
  • 121
  • 94
  • 71
  • 50
  • 50
  • 47
  • 40
  • 39
  • 39
  • 38
  • 37
  • 37
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
451

Simulações da SAR em virtude da exposição por tablets operados próximo à cabeça

Ferreira, Juliana Borges January 2016 (has links)
A grande maioria da população mundial está crescentemente exposta à radiação eletromagnética proveniente de fontes que muitas vezes estão localizadas nas proximidades do corpo. A radiação eletromagnética é considerada um agente possivelmente cancerígeno para as pessoas, classificação 2B indicada pela Organização Mundial da Saúde-OMS (WHO/IARC, 2011). Devido às preocupações em relação aos riscos associados a esta exposição existem normas que recomendam os valores máximos de exposição permitidos (ICNIRP, 1998; FCC, 2001). A correta avaliação das doses de radiação é, portanto, relevante. Este trabalho tem a finalidade de avaliar o impacto dos resultados do cálculo da dose da Taxa de Absorção Específica (SAR) em usuários expostos a radiação por tablets operando na faixa de radiocomunicações Wi-fi. Os três modelos existentes de cabeça humana utilizados serão um manequim homogêneo SAM phantom e dois modelos de cabeça realistas heterogêneos: um adulto masculino e uma criança masculina. Será também utilizado nas simulações um modelo masculino de criança que foi desenvolvido através de imagens de tomografia computadorizada (TC) pelo processo de segmentação feito no software AMIRA. Será utilizado um modelo genérico de tablet. Os parâmetros dosimétricos usados para simulação da SAR serão computados pelo software SEMCAD X que é baseado no Método das Diferenças Finitas no Domínio do Tempo (FDTD). Será criado também um código do Método FDTD através do software MATLAB que servirá para a escolha dos parâmetros do SEMCAD X. A distância entre o tablet e os modelos de cabeças varia de 50 mm a 300 mm. Os resultados da SAR serão comparados com os limites de exposição recomendados pelas normas internacionais. Também serão simuladas diferentes posições da antena no tablet. Da análise dos resultados foi constatado que os valores de SAR são muito baixos e todos os resultados ficaram dentro dos limites do psSAR recomendados pela FCC de 1,6 W/kg em cada 1 g de tecido e de 2 W/kg em cada 10 g de tecido estabelecidos pela ICNIRP. Comparando os valores de SAR do modelo SAM com o modelo DUKE, o modelo SAM se mostra conservador, porém quando a comparação é feita com as crianças o SAM deixa de ser conservador. / The vast majority of the world population is increasingly exposed to electromagnetic radiation from sources which are often located near to the body. Electromagnetic radiation is considered a possible carcinogen for people, classification 2B indicated by the World Health Organization-WHO (WHO/IARC, 2011). Due to concerns regarding the risks associated with this exposition there are regulations suggesting maximum allowed exposure values (ICNIRP, 1998; FCC, 2001). The correct evaluation of radiation doses is therefore relevant. This work aims to assess the impact of the results of the calculation of Specific Absorption Rate dose (SAR) in users exposed to radiation from tablets operating in the Wi-fi band. The three existing models of human head used are a homogeneous dummy SAM phantom and two heterogeneous realistic head models: a male adult and a male child. It will also be used in the simulations a male child model which was developed from computed tomography (CT) imaging using the AMIRA software for the segmentation process. A generic model of tablet is used. Dosimetric parameters used for simulation of the SAR are computed using the SEMCAD X software which is based on the Finite Difference Method in Time Domain (FDTD). A FDTD code was developed using the MATLAB software in order to help to choose the input SEMCAD X parameters. The distances between the tablet and the head of the models varies from 50 mm to 300 mm. SAR results are compared with the exposure limits recommended by international standards. Different antenna positions on the tablet are simulated too. Examining the results it was found that the SAR values are very low and all results are within the psSAR limits recommended by FCC (1,6 W/kg averaged over 1 g of tissue) and by ICNIRP (2 W/kg in 10 g of tissue). Comparing the SAR in the SAM model with the SAR in the DUKE model, the SAM model shows to be conservative. However, when compared with the children, the SAM is not conservative.
452

Implementação de um instrumento para medição da intensidade de fótons na faixa da mamografia / Implementation of an instrument for measuring the intensity of photons in the mammography range

Andreazzi, Mariana 07 February 2018 (has links)
Submitted by mariana andreazzi (mariana.andreazzi@gmail.com) on 2018-04-17T11:25:04Z No. of bitstreams: 1 Dissertação M.A.pdf: 1982076 bytes, checksum: ed75a1f8ed32ce6807b4f69ef83cf56b (MD5) / Approved for entry into archive by Cristina Alexandra de Godoy null (cristina@adm.feis.unesp.br) on 2018-04-18T18:22:44Z (GMT) No. of bitstreams: 1 andreazzi_m_me_ilha.pdf: 4488184 bytes, checksum: 3ae904bc1d08784b0b43e8a989b69419 (MD5) / Made available in DSpace on 2018-04-18T18:22:44Z (GMT). No. of bitstreams: 1 andreazzi_m_me_ilha.pdf: 4488184 bytes, checksum: 3ae904bc1d08784b0b43e8a989b69419 (MD5) Previous issue date: 2018-02-07 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Foi implementado um instrumento com a finalidade de medir a intensidade (taxa de fluência de energia) de fótons na faixa de mamografia (22 a 33 kVp) e a tensão do tubo de um mamógrafo. O instrumento é constituído por uma câmara com sensor piroelétrico de metaniobato de chumbo (PbNb2¬O¬¬6) e seu circuito de condicionamento de sinais. Utilizou-se poliácido lático para confeccionar a câmara piroelétrica em uma impressora 3D. O circuito de condicionamento de sinais é um conversor corrente-tensão de alta sensibilidade. A intensidade da radiação foi determinada a partir da taxa de exposição medida com uma câmara de ionização. Uma simulação do espectro de emissão do molibdênio, na faixa de 22 a 33 kVp, foi realizada com o sensor piroelétrico e o software DTSA-II, e comparada com a o feita com um sensor de Si(Li), comumente empregado. Os resultados obtidos mostram que a resposta do instrumento implementado é linear com a tensão do tubo de raios-X e com a intensidade da radiação, e que o espectro de emissão do molibdênio pode ser determinado com o instrumento piroelétrico. / An instrument to measure the intensity (energy fluence rate) of photons in the mammography range (22 to 33 kVp) and the tube voltage of a mammograph. The instrument consists of a chamber with a pyroelectric sensor of lead methaniobate (PbNb2O6) and its signal conditioning circuit. Polyacid was used to make the pyroelectric chamber in a 3D printer. The signal conditioning circuit is a high sensitivity current-voltage converter. The intensity of the radiation was determined from the exposure rate measured with an ionization chamber. A simulation of the emission spectrum for molybdenum, in the range of 22 to 33 kVp, was performed with the pyroelectric sensor and the DTSA-II software, and compared to that simulated using the commonly used Si (Li) sensor. The results show that the response of the implemented instrument is linear with the X-ray tube voltage and the intensity of the radiation, and that the emission spectrum of molybdenum can be determined with a pyroelectric instrument.
453

Comparações entre doses pediátricas periféricas provenientes de radioterapia conformal e de intensidade modulada

Santos, Marinei do Rocio Pacheco dos 20 August 2010 (has links)
Esta pesquisa apresenta e compara medidas de doses pediátricas periféricas em radioterapia, em regiões de tireóide, coração, mama, abdome, medial de ovários e testículos. Tais doses foram obtidas com TLDs de LiF:Mg,Ti (TLD-100) em pó, posicionados em três objetos simuladores humanóides com tamanhos de crianças de dois, cinco e dez anos, feitos de polietileno de alta densidade e completamente preenchidos com água. Foi empregado um acelerador linear Varian Clinac 600CD para irradiar a cabeça dos três objetos simuladores, com feixes de Raios X produzidos com potencial de 6 MV, com três diferentes planejamentos craniais: (a) IMRT sliding window com o colimador multifolhas rotacionado em 0º, (b) IMRT sliding window com o colimador multifolhas rotacionado em 90º e (c) planejamento conformal (3D). As doses aplicadas foram de 300 cGy e 600 cGy com cinco campos coplanares para todos os planejamentos. Como resultado deste trabalho observa-se que as doses obtidas para todas as irradiações são muito baixas, quando comparadas aos valores de doses determinísticas para as regiões de maior interesse em proteção radiológica e que IMRT 90º proporciona maior blindagem para a radiação de fuga que se direcionaria para o corpo do paciente, oferecendo vantagens quando comparado com os planejamentos conformal e IMRT 0º. / This research presents and compares peripheral pediatric doses measurements in radiation therapy, for of thyroid, heart, breast, abdomen, ovaries and testicles regions, obtained with TLD LiF: Mg, Ti (TLD-100) powder, placed on three humanoid phantoms with sizes of children as two, five and ten years old, made of high density polyethylene and completely filled with water. It at linear accelerator Varian Clinac 600CD was employed to irradiate the heads of the three phantoms, with X-rays beams generated by a potential of 6 MV, with three different skull plannings: (a) IMRT sliding window with multileaf collimator rotated 0°, (b) IMRT sliding window with the multileaf collimator rotated 90° and (c) conformal planning (3D). The doses applied were 300 cGy and 600 cGy with five coplanar fields for all cares planning. The results show that the doses obtained for the all irradiations are very low compared to deterministic dose values deterministic for the regions of greater interest in radiological protection and that IMRT 90º provides more shielding for leakage radiation which would be directed to patient's body, offering advantages when compared to conformal planning and IMRT 0º.
454

Medida do Kerma ar na superfície de entrada em tomografia computadorizada odontológica

Legnani, Adriano 26 August 2011 (has links)
O presente trabalho tem por objetivo mensurar o Kerma Ar na Superfície de Entrada, Ka,e, em Tomografia Computadorizada Odontológica (TCO), também conhecida como CBCT (Cone Beam Computed Tomography). A coleta de dados foi realizada em seis clínicas de radiodiagnóstico odontológico. Destas, cinco possuem o aparelho de TCO e uma possui o aparelho de raios X panorâmico. O arranjo experimental é composto de um simulador humanóide preenchido com água. Este simulador tem dimensões semelhantes a de uma criança, com o diâmetro lateral da cabeça igual a 14,5 cm. O Ka,e foi medido com dosímetros termoluminescentes sobre a superfície do simulador. As localizações dos dosímetros correspondem aos olhos e glândulas salivares (parótida). A técnica empregada engloba toda a região da cabeça, como um exame craniofacial. A configuração de FOV (Field of View) estendido oferece os maiores valores de dose. Os parâmetros técnicos (kVp e mAs) e os diferentes modos de execução do FOV, influenciam os resultados da dose. Além disso, há a diferença entre os resultados de três tomógrafos do mesmo modelo. Há também a falta de simetria na distribuição do Ka,e entre as duas faces do simulador. O tomógrafo de menor Ka,e, neste trabalho, pertence a mesma marca daqueles com os menores resultados descritos na literatura. / This aim of this work is to measure the Entrance Surface Air Kerma, Ka,e, in Dental Computed Tomography, also known as CBCT (Cone Beam Computed Tomography). Data collection was conducted in six dental radiology clinics. Five of these have dental computed tomography scanner and one of them has a panoramic X ray scanner. The experimental essay is composed of a humanoid phantom filled with water. In addition, it has similar dimensions to a child that has head with lateral diameter of 14.5 cm. The Ka,e was measured with thermoluminescence dosimeters on the surface of the phantom. The locations of the dosimeters correspond to eyes and salivary gland (parotid glands). The technique used comprises the total area of the head, like a craniofacial examination. The configuration of extended FOV provides the highest Ka,e values. The technical parameters (kVp and mAs) and different modes of executing the FOV influenced the Ka,e results. Furthermore, there were differences between the results of three scanners of the same model. There is also a lack of symmetry on Ka,e distribution between both sides of the phantom. The CBCT with the lowest Ka,e on this work is of the same type of those with the lowest doses related on literature.
455

Avaliação da dose de radiação: angiotomografia coronariana - métodos retrospectivo e prospectivo

Braghini, André Luís 28 May 2015 (has links)
O objetivo deste estudo foi avaliar a dose efetiva de radiação nos exames de CCTA através dos métodos Prospectivo e Retrospectivo do ECG. A coleta de dados foi realizada na Clínica Sabedotti, em Ponta Grossa – PR, em um equipamento General Electric modelo VCT XT, de 64 linhas de detecção. A dose efetiva foi mensurada para 30 casos, selecionados aleatoriamente do Picture Archival and Communication System – PACS, Arquivamento e Comunicação de Imagens, a partir do Produto Dose Comprimento (DLP) reportado pelo equipamento para cada exame e pelo fator de conversão (EDLP) definido pela Comissão Europeia para região cardíaca (EDLP = 0,014). Os resultados apontaram diferenças expressivas quanto à dose de radiação entregue ao paciente de acordo com o método de aquisição empregado, Retrospectivo ou Prospectivo do ECG. / The aim of this study was to evaluate the effective dose received by patients undergoing CCTA in both acquisition methods in the period June 1st to October 30th, 2013. Data collection was performed at the Clínica Sabedotti in Ponta Grossa/PR, with General Electric Equipment VCT XT, 64 detections lines. The effective dose was measured from the thirty cases randomly selected of Picture Archival and Communication System – PACS, reported by Dose Lenght Product (DLP) equipment for each examination and the conversion factor (EDLP) set by the European Commission for cardiac region (EDLP = 0.014). The results showed significant differences in radiation dose delivered to the patient according to the employee acquisition method, Retrospective or Prospective of ECG.
456

Exposição ocupacional às radiações ionizantes durante cirurgias ortopédicas guiadas fluoroscopicamente

Santos, Romilda Prado dos 16 February 2012 (has links)
A Radiologia tem sido considerada uma das áreas da Medicina que mais se desenvolve, especialmente com o aporte de novas tecnologias. Entre as aplicações da Radiologia Intervencionista destaca-se a utilização da fluoroscopia no centro cirúrgico em complemento às cirurgias ortopédicas, objeto da presente pesquisa. Entretanto, alguns complexos e longos procedimentos guiados fluoroscopicamente podem resultar em altos níveis de exposição ocupacional às radiações ionizantes para equipe de cirurgia ortopédica e trabalhadores de saúde, induzir sérios danos à saúde. Levando em conta esses aspectos, o objetivo geral dessa pesquisa consiste em determinar a exposição ocupacional da equipe de cirurgia ortopédica em procedimentos guiados por fluoroscopia e verificar dentre as cirurgias observadas a que oferece maior exposição ocupacional às radiações ionizantes, como também, a aplicação dos princípios básicos de proteção radiológica nestes procedimentos. A metodologia utilizada para essa pesquisa foi a qualiquantitativa do tipo exploratória. A pesquisa foi realizada no Hospital de Clínicas da Universidade Federal de Curitiba (UFPR). Os sujeitos pesquisados foram os membros da equipe de cirurgia ortopédica, ou seja, médicos ortopedistas, residentes, anestesias, instrumentador cirúrgico, técnicos e auxiliares de enfermagem, e enfermeiros. A coleta de dados foi realizada de 01 de janeiro a 30 de maio de 2011. Contribuíram para a pesquisa, 44 trabalhadores que responderam uma entrevista coletiva, e um questionário com 25 perguntas fechadas. foi constituídos quatro grupos de onze participantes cada, seguida de análise documental e de monitoração da área pesquisada e individual. Os resultados mostraram que os profissionais de saúde do setor pesquisado expõem-se às radiações ionizantes, devido à demanda de cirurgias guiadas por equipamentos emissores de radiação ionizantes fluoroscopicamente, e a falta de conhecimento em radioproteção. Diante dessas constatações foram sugeridas pelos grupos medidas de prevenção a essas exposições de modo a minimizar possíveis efeitos biológicos das radiações ionizantes. Foi concluído que existe exposição ocupacional com os trabalhadores do setor pesquisado, os mesmos tem pouco conhecimento quanto ao uso dos equipamentos de radioproteção nos procedimentos cirúrgicos com equipamentos emissores de radiações ionizantes, não usam corretamente os monitores individuais. / Radiology has been considered one of the areas of medicine that most devel-ops, especially with the contribution of new technologies. Among the applications of Interventional Radiology highlights the use of fluoroscopy in the surgical center in addition to co-orthopedic surgeries, the object of the present research. Entretan-to some complex and lengthy fluoroscopically guided procedures can result in high levels of occupational exposure to ionizing radiation for e-quipe orthopedic surgery and health workers, induce serious damage to health. Considering these aspects, the general objective of this research is to de-termine the occupational exposure of the team of orthopedic surgery proce-dures guided by fluoroscopy and verify observed among the surgeries that offer greater occupational exposure to ionizing radiation, but also the application of basic principles of radiological protection in these procedures. The methodology for this research was the qualitative and quantitative exploratory type. The research was conducted at Hospital de Clinicas, Federal University of Curitiba (UFPR). Study subjects were members of the team of orthopedic surgery, or orthopedic doctors, residents, anesthesia, surgical instrumentator, technicians and nursing assistants, and nurses. Data collection was performed from January 1 to May 30, 2011. Contributors to the survey, 44 workers who answered a news conference, and a questionnaire with 25 closed questions of. was divided in four groups of eleven participants each, followed by document analysis and monitoring of the area and searched individually. The results we-strated that the health sector professionals surveyed were exposed to ionizing radiation, due to demand-driven surgery equipment emitting ionizing radiation fluoroscopically, and the lack of knowledge in radioprote-tion. Before these findings were suggested by the groups pre-vention measures of these exposures to minimize possible biological effects of ionizing radiation-tions. It was concluded that occupational exposure exists with re-worked in the sector researched, they have little knowledge about the use of radiation protection equipment in surgical procedures with equipment emitting ionizing radiation, properly use the monitors indi-tions.
457

Avaliação da dose de radiação ocupacional em medicina nuclear nos exames de cintilografia de perfusão miocárdica

Komatsu, Cássio Vilela 29 November 2013 (has links)
Em medicina nuclear, os trabalhadores diretamente envolvidos nos exames são frequentemente expostos à radiação ionizante. Neste estudo, utilizou-se um detector Geiger-Mueller (GM) para medir as doses da radiação ocupacional durante a realização de algumas das etapas mais críticas para a exposição à radiação em exames de cintilografia de perfusão miocárdica (CPM), são elas: 1) fracionamento das atividades no preparo das seringas; 2) administração do radiofármaco Tecnécio99m-sestamibi nas etapas de repouso e estresse; e 3) aquisição das imagens diagnósticas na sala de exames. Na avaliação, procurou-se discriminar e relacionar o tempo de experiência profissional às doses medidas. Para isso, foi acompanhado um total de 494 procedimentos entre os meses de outubro e dezembro de 2012, sendo 229 seringas preparadas no fracionamento das atividades, 165 administrações de radiofármaco (55 na etapa de repouso realizadas por profissionais com tempo de experiência superior a 2 anos, 55 na etapa de repouso realizada por profissionais com tempo de experiência inferior a 1 ano, e 55 na etapa de estresse), e 100 aquisições de imagem (50 na etapa de repouso e 50 na etapa de estresse). Foram avaliados também os registros das doses obtidas na monitoração individual por dosimetria termoluminescente (TLD), realizada entre julho de 2010 e dezembro de 2012. Os resultados obtidos com o detector GM, quando extrapolados para o acúmulo de doses no período de um ano, mostraram-se significantes em relação ao limite anual de 20 mSv determinado pela legislação brasileira para uma média em cinco anos consecutivos. As doses médias acumuladas nos procedimentos avaliados corresponderam aos seguintes percentuais em relação a esse limite: 1) 13%, no fracionamento das atividades; 2) 8% e 35%, na administração dos radiofármacos das etapas de repouso e estresse, respectivamente; e 3) 4% e 10%, na aquisição das imagens das etapas de repouso e estresse, respectivamente. Esses valores foram compatíveis com os resultados da monitoração individual por TLD, cujos valores registrados foram superiores (34,6% a 63,2% do limite de 20 mSv) pelo fato de não discriminar as doses em cada procedimento. Em virtude dos valores de dose encontrados, o uso de equipamentos de proteção individual e a agilidade na realização dos procedimentos, ligada a experiência profissional, contribuem de forma efetiva para a redução destes valores de dose. / In nuclear medicine, workers directly involved in the exams are frequently exposed to ionizing radiation. In this study, a Geiger-Mueller detector was used to measure the occupational radiation doses while conducting some of the steps with critical radiation exposure during myocardial perfusion scintigraphy exams, which are: 1) fractionation of radiopharmaceutical activities in single-dose syringes, 2) Technetium99m-sestamibi administration during rest and stress steps, and 3) diagnostic images acquisition in the exam room. In the evaluation, it was sought to distinguish and relate the length of professional experience to measured doses. For that reason a total of 494 procedures were followed up including 229 fractionation of radiopharmaceutical activities in single-dose syringes, 165 radiopharmaceutical administrations (55 during rest step performed by professionals with experience time above two years, 55 during rest step performed by professionals with experience time below one year, and 55 during stress step), and 100 image acquisitions (50 during rest step and 50 during stress step). Dose records obtained during individual monitoring by thermoluminescent dosimetry (TLD) conducted between July 2010 and December 2012 were also evaluated. The results obtained by the GM detector, when extrapolated for dose accumulation over one year, proved to be significant in relation to the 20 mSv annual limit determined by Brazilian regulations to an average over five consecutive years. The mean accumulated doses evaluated during the procedures correspond to the following percentages relative to the annual limit value: 1) 13%, at the fractionation of radiopharmaceutical activities, 2) 8% and 35%, during rest and stress steps of radiopharmaceuticals administration, respectively, and 3) 4% and 10%, during rest and stress images acquisition, respectively. These values are consistent to the results of individual monitoring by TLD. These values were consistent to the results of individual monitoring by TLD, whose registered values were higher (34.6% to 63.2% of the limit of 20 mSv) due to the fact that they don't discriminate the dose by each procedure. Because of the dose values found, the use of personal protective equipment and the agility in procedures, linked to professional experience, effectively contribute to the reduction of these dose values.
458

Utilização do mapa espacial de radiação e dose acumulada como ferramenta para otimização de doses em pacientes e trabalhadores nas clínicas de medicina nuclear / Employment of the radiation and cumulative dose spatial map as a tool for optimization of doses in patients and workers in nuclear medicine clinics

Lopes, Pedro Henrique Silvestre 18 December 2015 (has links)
Esse estudo tem por objetivo geral propor um mapa espacial de doses como ferramenta auxiliar na avaliação da necessidade de otimização de ambientes em serviços de medicina nuclear e, por objetivos específicos, avaliar as dosimetrias individuais dos trabalhadores; analisar a estrutura física dos serviços de medicina nuclear; avaliar as taxas de dose do ambiente. A pesquisa realizada se caracteriza como um estudo de caso, de natureza exploratória e explicativa, em três Serviços de Medicina Nuclear estabelecidos na região Noroeste do Estado do Paraná. Os resultados obtidos indicaram que as taxas de dose avaliadas e a dosimetria dos trabalhadores, em todas as dependências dos serviços pesquisados, respeitam os limites de doses anuais, mas algumas excedem os limites de investigações preconizados na norma NN-CNEN 3.01 (2014). Concluiu-se que o mapa espacial de dose é uma ferramenta importante para os serviços de medicina nuclear, pois facilita a visualização das áreas com maior concentração de radiação, bem como a revisão contínua de tais medidas e recursos para identificar quaisquer falhas e deficiências na sua aplicação, corrigi-las e evitar suas repetições, além de verificar regularmente se os objetivos de proteção radiológica estão sendo alcançados. / This study has as general aim to propose a spatial map of doses as an auxiliary tool in assessing the need for optimization of the workplace in nuclear medicine services. As specific aims, we assessed the workers individual dosimetry; we analyzed the facilities of the nuclear medicine services; and we evaluated environment exposure rates. The research is characterized as a case study, with an exploratory and explanatory nature. It was conducted in three Nuclear Medicine Services, all established in the Northwest of the Paraná State. Results indicated that the evaluated dose rates and workers dosimetry, in all the dependencies of the surveyed services, are within the limits of annual doses. However some exceeded the limits recommended in the standard CNEN-NN 3:01 (2014). It was concluded that the spatial map dose is an important tool for nuclear medicine services because it facilitates the visualization of areas with highest concentration of radiation, and also helps in the constant review of these measures and resources, aiding in the identification of any failures and shortcomings, providing resources to correct any issues and prevent their repetition. The spatial map dose is also important for the regular inspection, evaluating if the radiation protection objectives are being met.
459

Avaliação das condições de radioproteção em radiologia intraoral

Miguel, Cristiano 20 March 2015 (has links)
Este estudo apresenta a avaliação das condições de radioproteção em radiologia intraoral. A pesquisa foi realizada em parceria com o Instituto de Radioproteção e Dosimetria da Comissão Nacional de Energia Nuclear (IRD/CNEN). A coleta de dados foi feita por meio de pesquisa de campo quantitativa de caráter descritivo durante o período de setembro de 2013 a dezembro de 2014. Participaram voluntariamente do estudo, odontólogos da cidade de Curitiba - PR que atuam com equipamentos de raios X intraorais. A amostra da pesquisa consistiu em 97 odontólogos e 130 equipamentos intraorais instalados em 74 locais de atendimentos distribuídos em 39 bairros da cidade de Curitiba - PR. Foram avaliadas 21 clínicas odontológicas, 40 consultórios odontológicos, 1 hospital universitário, 8 unidades municipais de atendimento odontológico e 4 instituições de ensino. Os dados foram coletados por meio de formulários preenchidos pelo pesquisador, pelos odontólogos, e pela avaliação de controle de qualidade dos equipamentos de raios X. As avaliações de dose de entrada na pele, tamanho de campo de radiação e filtração total foram realizadas com kits dosimétricos fornecidos e avaliados pelo IRD/CNEN. As medidas do tempo de exposição e da tensão dos equipamentos de raios X foram realizadas com detectores não invasivos. A dose ocupacional dos odontólogos foi verificada com dosímetros termoluminescentes. Por meio de formulários e de um questionário (aprovado pelo Comitê de Ética em Pesquisa de Seres Humanos - UTFPR) foi possível identificar as características técnicas dos equipamentos, avaliar os procedimentos de trabalho e o conhecimento dos odontólogos em relação à radioproteção. Com os resultados da pesquisa é possível destacar que apenas 10% dos equipamentos avaliados atendem a todas as exigências das normas de radioproteção do Brasil. Entretanto, 84,5% das doses de entrada na pele dos pacientes foram consideradas como conforme. Em relação à exposição ocupacional, a radiologia intraoral mostra-se segura, porém os procedimentos de trabalho dos odontólogos, referentes à radioproteção podem ser otimizados. Grande parte dos odontólogos não utiliza posicionador na sua rotina, fazem o processamento químico das radiografias através do método visual, usam sempre o mesmo tempo de exposição para todas as regiões anatômicas e não observam os pacientes durante a aquisição das imagens. O estudo sugere que a falta de conhecimento e de interesse dos odontólogos em relação à radioproteção, a falta de manutenção periódica dos equipamentos e a falta de fiscalização da agência regulamentadora são os responsáveis pelas não conformidades observadas. / This study presents an evaluation of the radiation protection conditions in intraoral radiology. The survey was conducted in partnership with the Radiation Protection and Dosimetry Institute of the National Commission of Nuclear Energy (IRD/CNEN). Data collection was performed using quantitative field research in a descriptive way during the period of september 2013 to december 2014. The study had the voluntarily participation of dentists in the city of Curitiba – PR, working with intraoral X-ray equipment. The research sample consisted of 97 dentists and 130 intraoral equipments which are installed in 74 care locations distributed in 39 neighborhoods in the city of Curitiba - PR. The study evaluated 21 dental clinics, 40 dental offices, 1 hospital, 8 municipal units of dental care and 4 educational institutions. Data were collected through forms checked out by the researcher, by dentists and the quality control evaluation of X-ray equipment. The evaluation of the entrance skin dose, radiation field size and total filtration were performed with dosimetric kits supplied and evaluated by IRD/CNEN. The exposure time and voltage measures of X-ray equipment were performed with noninvasive detectors. Occupational dose was measured with thermoluminescent dosimeters. Through appropriate forms and a questionnaire (approved by the Ethics Committee of Human being Research - UTFPR) it was possible to identify the technical characteristics of the equipment, review the working procedures and knowledge of the dentists in relation to radiation protection. Among the search results it is important to emphasize that only 10% of the evaluated equipment reaches all requirements of the Brazilian radiation protection standards. However, 84,5% of the entrance skin dose delivered to the patients was considered in accordance. Regarding occupational exposure, the intraoral X-rays seem to be safe, but the dentist’s working procedures, related to the radiation protection, can be optimized. Most dentists do not use positioners in their routine, make the chemical processing of X-rays through the visual method, routinely use the same exposure time for all anatomic regions and do not observe patients during image acquisition. The study suggests that the dentists’s lack of knowledge and interest in radiological protection, the lack of equipment regular maintenance and the lack of regulatory agency supervision are the responsible for the nonconformities observed.
460

Avaliação de Kerma na superfície de entrada da pele em pacientes pediátricos do Hospital de Clínicas de Curitiba

Porto, Lorena Elaine 09 April 2010 (has links)
CAPES / No presente trabalho foram feitas medidas de dose recebida pelos pacientes pediátricos em exames de radiográficos de tórax em uma amostra de 386 exposições nas projeções AP/PA e Perfil. Os pacientes foram divididos em nas faixas etárias de 0-1 ano, 1-5 anos, 5-10 anos e 10-15 anos. Os exames foram realizados no Hospital de Clínicas da UFPR. Foi medida inicialmente a dose de entrada na pele com dosímetros termoluminescentes TLD-100 em uma amostra de 68 exposições, distribuídos pelas faixas etárias adotadas. A dose foi também determinada utilizando-se cálculos dosimétricos, que faz a determinação de dose para cada paciente a partir do rendimento do aparelho de raios X. O programa utiliza como dados de entrada a massa do paciente, a idade, a distância foco-pele, os dados da técnica radiográfica empregada (kV e mAs) e o valor de uma medida do rendimento feita com câmara de ionização para fins de calibração. Os primeiros dados avaliados mostraram doses maiores para os pacientes mais jovens. Uma mudança na técnica radiográfica dos exames contribuiu para a redução das doses. Foi avaliado todo o procedimento radiográfico e ficou caracterizada a necessidade de uma adequação da técnica radiográfica e uma constante otimização de todo o procedimento. Os dados foram colhidos novamente em 2007 e depois em 2009. Num primeiro momento os níveis de dose se mantiveram. Em 2009 os valores voltaram a subir devido ao aumento da carga (mAs). Os dados obtidos foram então comparados com os limites de dose permissíveis determinados pelos órgãos competentes. / In the present work absorbed doses by pediatric patients in chest radiographs were measured in 386 x-ray examinations in AP/PA and LAT projections. The patients were divided in age groups of 0-1 years, 1-5 years, 5-10 years and 10-15 years. The examinations were made at the pediatric room of Clinical Hospital of the Federal University of Paraná. Initially the entrance skin dose was measured with thermoluminescent dosimeters TLD-100 in 68 expositions, distributed in the age groups. The dose was also determined with the software dosimetric calculations that calculates the dose for each patient, from the X-ray equipment yield. The program uses the following data as input: patient mass, age, skin-focus, radiographic technique (kV, mAs), and the yield measurement made with an ionization chamber for calibration. The first evaluated data showed higher doses for the younger patients. A change in the radiographic technique of the examinations contributed to the reduction of the doses. The whole radiographic procedure was evaluated and, thus, showed that the radiographic technique had to be adjusted and the procedure as a whole had to be constantly optimized. Dates were measurement in 2007 again and after 2009. At a first moment the dose levels if had kept. In 2009 the values had come back to go up due to the increase of the load (mAs). The doses were then compared with the regulatory dose limits.

Page generated in 0.2669 seconds