• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 244
  • 4
  • 1
  • Tagged with
  • 252
  • 87
  • 75
  • 64
  • 47
  • 46
  • 38
  • 35
  • 33
  • 32
  • 30
  • 30
  • 28
  • 28
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
221

Formação técnica no ensino médio e demanda estudantil: um estudo no curso profissionalizante em edificações

Leite, Warwick Ramalho de Farias 21 July 2009 (has links)
Made available in DSpace on 2015-05-07T15:08:47Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 653497 bytes, checksum: f068b7e972cc06af86fb8d2f00f56f84 (MD5) Previous issue date: 2009-07-21 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The research proposal shows the concern with the small demand for vocational technical training mid-level technician from buildings in João Pessoa city. This concern is the fact that the building industry following the construction of buildings has found broad market in the capital of the state of Paraiba, however, the professionals in the area have little, as data presented in the body of work. From the study of possible causes, is an explanation about the Brazilian government implemented Education policies with its consequences in the evolution of Professional Education and to analyze the effects of these and other causes related to the problems of social order that could have stepped in little demand of the Construction Building Technologic Course. / A pesquisa proposta revela a preocupação com a pequena demanda para formação técnica profissionalizante de nível médio técnico de edificações na cidade de João Pessoa. Essa preocupação prende-se ao fato de que a Indústria da Construção Civil no seguimento da construção de edificações tem encontrado amplo mercado na Capital do Estado da Paraíba, contudo, os profissionais da área têm escasseado, conforme dados apresentados no corpo do trabalho. A partir do estudo das possíveis causas, se faz uma explanação sobre as Políticas Públicas Brasileiras para a Educação implementada com suas conseqüências na evolução da Educação Profissional e procura analisar os efeitos dessas causas e de outras relacionadas aos problemas de ordem social que possam ter interferido na pouca procura pelo Curso Técnico em Edificações.
222

A percepção do usuário de habitação unifamiliar em relação ao sistema construtivo industrializado avaliação do grau de satisfação / Theuser s perception of family housing in relation to industrialized building system Evaluation of the degree of satisfaction

Silva, Larissa Soriani Zanini Ribeiro Soares 20 December 2013 (has links)
The evaluation of the satisfaction of residential building users after its delivery to the residents is extremely important to the real estate market. This information enables to create a database to guide the decision taken by the designers in the depeloping of a project of a new product and/or its own improvement. In the case of the introduction of technological inovations to the construction processes key element to the productivity raise the informations related to what and the intensity of the renovations that are accepted by the consumers are important to project a new product to which a bigger degree of industrialization is desired. This work is based on the evaluation of the satisfaction by means of the perception of the user considering two residential buildings that use different building processes and which has as feature the incorporation of a high technological renovation to its production. The first is compound of armed massive walls of reincorced concrete shaped in loco and the second of pre-built panels, compound by a reinforced concrete structure and sealing in ceramic blocks, produced in factories and built in local by the tilt up system. A third residential building, built by the conventional building system (masonry in loco), was also evaluated and accepted as the reference standard.The satisfaction compared by the users of these three different types of residential building was used to evaluate the resident s acceptance level related to the mentioned industrialized houses . The results indicated that a reduction in conservatism of society with respect to industrialized building systems. / A avaliação do grau de satisfação dos usuários de edificações residenciais após a sua entrega aos moradores é de suma importância para o mercado imobiliário. Esta informação possibilita criar um banco de dados para nortear a tomada de decisão dos projetistas no desenvolvimento do projeto de um novo produto e/ou aprimoramento do mesmo. No caso da introdução de inovações tecnológicas aos processos construtivos - elemento chave para o aumento de produtividade - as informações relacionadas ao o que e a intensidade das inovações que são aceitas pelos consumidores são importantes ao projetar um novo produto ao qual se deseja incorporar um maior grau de industrialização. Este trabalho versa sobre a avaliação do grau de satisfação por meio da percepção do usuário realizada em dois conjuntos residenciais que usam processos construtivos distintos e que têm como característica o fato de incorporarem inovação tecnológica à sua produção. O primeiro é composto por paredes maciças de concreto armado moldadas in loco e o segundo por painéis pré-fabricado, compostos por estrutura de concreto armado e vedação em blocos cerâmicos, produzidos em usinas e montados no local pelo sistema tiltup . Um terceiro conjunto residencial, construído pelo sistema construtivo convencional (alvenaria executada in loco), também foi avaliado e admitido como padrão de referência. A comparação do Grau de Satisfação dos usuários desses três diferentes tipos de edificações residenciais foi usada para avaliar o nível de aceitação dos moradores em relação às ditas casas industrializadas . Os resultados obtidos permitem verificar uma redução no conservadorismo da sociedade com relação aos sistemas construtivos industrializados. / Mestre em Engenharia Civil
223

Cidade e universidade : arquitetura e configuração urbana do Campus Centro da UFRGS

Tonioli, Renata Manara January 2014 (has links)
A Universidade Federal do Rio Grande do Sul (UFRGS) possui sua estrutura física, em Porto Alegre, organizada em quatro campi: Campus Centro, Campus Saúde, Campus Olímpico e Campus do Vale. Núcleo original da instituição, o Campus Centro se localiza em região central da cidade e é composto por dois quarteirões contíguos. Com a forma de um polígono, o campus possui um conjunto edificado heterogêneo formado por prédios construídos entre os anos de 1898 e 2013. Antes mesmo de serem agrupadas para formar a Universidade de Porto Alegre (UPA) em 1934, as escolas autônomas de ensino superior de espírito positivista fundadas no final do século XIX já possuíam suas sedes implantadas nos dois quarteirões. Federalizada em 1951, a UFRGS ali mantém prédios de importantes unidades de ensino, além da sede da instituição. O conjunto edificado reúne exemplares com características das arquiteturas eclética e modernista, reconhecidos como patrimônio cultural a nível institucional, nos âmbitos municipal, estadual e nacional. A configuração do campus possui relação direta com a evolução urbana da cidade, respondendo aos diversos processos de constituição de sua estrutura urbana e suas circunstâncias históricas, socioeconômicas e ambientais. Quando os primeiros edifícios foram construídos, por volta de 1900, o núcleo urbano de Porto Alegre se restringia à ponta da península, e a região do campus apresentava-se como um descampado, fora dos limites da cidade. Com o crescimento e desenvolvimento da cidade, o núcleo urbano sofreu grande expansão, e a área antes periférica, poucas décadas depois já fazia parte do conturbado centro da capital. A presente dissertação pretende investigar a origem e o desenvolvimento do Campus Centro da UFRGS, assunto que até o presente momento não possui estudos consistentes. Abordando tanto as questões de configuração urbana relacionadas ao espaço dos dois quarteirões do Campus Centro quanto as questões específicas relativas à arquitetura das edificações e do espaço aberto que os compõe, o estudo busca contribuir para a documentação e o conhecimento do tema. / The Federal University of Rio Grande do Sul (UFRGS) has, in Porto Alegre, a multi campi structure composed of the Downtown Campus, Health Campus, Olympic Campus and Valley Campus. UFRGS Downtown Campus, which is the foundational core of the institution, is located in Porto Alegre’s central district and is composed by two contiguous city blocks. Conformed like a polygon, the campus is composed by an heterogeneous set of buildings made between 1898 and 2013. Even before being assembled to create Porto Alegre University (UPA) in 1934, 19th century positivism orientated autonomous colleges were already located over these blocks. After its federalization on 1951, UFRGS still holds several important faculty buildings there, other than its head offices. The set of buildings on the Downtown Campus is composed by exemplars with features of the eclectic and modernist architectures, recognized as cultural heritage institutional, at municipal, state and national levels. Campus configuration holds close relation with city’s urban development, responding to distinct processes of its urban structure generation and historical, socioeconomical and environmental circumstances. When the first colleges where built, around 1900, Porto Alegre’s urban area was restricted to the peninsula’s site, and the university blocks where part of an unoccupied zone outside city limits. With city’s growth and development, the urban core has undergone extensive expansion and the area, once peripheral region, some decades later was part of the troubled center of the capital. This work aims to deal with the origin and development of the Central Campus of UFRGS, subject until now has no consistent studies. Addressing both the issues of urban configuration related to space two city blocks as the specific issues relating to the architecture of the buildings and the open space, the study seeks to contribute to the documentation and knowledge of the topic.
224

Análise térmica e energética de uma edificação residencial climatizada com sistema de Fluxo de Refrigerante Variável -VRF Fernando Pozza

Pozza, Fernando January 2011 (has links)
O trabalho apresenta uma análise térmica e energética de uma edificação localizada na zona bioclimática 1, que compreende as cidades mais frias do Brasil. A análise foi desenvolvida com o auxílio do programa de simulação dinâmica de edificações EnergyPlus em que foi determinado o consumo anual de energia elétrica de toda a edificação existente, bem como o consumo do sistema HVAC (Aquecimento, Ventilação e Ar Condicionado) do tipo split com ciclo reverso. O sistema HVAC existente representa 42% do consumo total de energia elétrica da edificação sendo que o aquecimento totaliza 89% do consumo do sistema HVAC. A avaliação do conforto térmico dos ambientes climatizados da edificação foi realizada tendo como referência as zonas de conforto de inverno e de verão definidas pela ASHRAE Standard 55-2004. Os ambientes apresentaram um percentual de 7,6 % a 33% das horas de operação do sistema HVAC fora da zona de conforto térmico de inverno da ASHRAE, considerando somente a temperatura operativa. A partir dos resultados da simulação da edificação existente foram propostas modificações na envoltória e o uso de um sistema de ar condicionado com tecnologia VRF (fluxo de refrigerante variável) a fim de reduzir o consumo de energia pelo HVAC e o número de horas desconfortáveis. A utilização de vidros duplos de maior transmissividade, superfícies com cores de maior absortividade solar, lã de vidro nas paredes externas e internas duplas e placas de EPS (Poliestireno Expandido) no piso da edificação, apresentaram ótimos resultados, reduzindo o consumo total de energia elétrica em 18,2% e o consumo do sistema HVAC passou a representar apenas 29,6% do total de energia da edificação. Após o aprimoramento da edificação foram selecionadas, a partir de catálogos de fabricantes, as máquinas com tecnologia VRF que atendessem a máxima carga térmica entre os dias de projeto ou arquivo climático sob determinadas condições. Os resultados obtidos com o sistema VRF apresentaram uma redução de 32,8% sobre o consumo de energia do sistema de HVAC e de 9,3 % sobre o consumo total de energia elétrica da edificação quando comparado com um ar condicionado tradicional do tipo split. Com a melhoria na envoltória e o uso da tecnologia VRF para climatização o percentual de horas fora das zonas de conforto da ASHRAE foram menores que os 4% estabelecido pela norma, quando considerado a temperatura operativa. O sistema VRF foi simulado adaptando o módulo de simulação de serpentinas de expansão direta com compressores de velocidade variável, do EnergyPlus, para quatro faixas de capacidades distintas do compressor (60%, 80%, 100% e 120%) e para cada faixa foram inseridas as correlações de desempenho da capacidade e potência elétrica de aquecimento e refrigeração para diferentes condições de operação. Nas simulações foram considerados a perda de desempenho e o consumo elétrico para a operação de degelo com ciclo reverso para temperaturas externas inferiores a 7º C. As simulações com o sistema VRF acoplado a edificação comprovam a capacidade de economizar energia elétrica, além de apresentar o menor custo especifico da energia para aquecimento em relação aos sistemas radiantes. / This dissertation presents the thermal and energetic analysis of a building located in the bioclimatic zone 01, which comprises the coldness regions of Brazil. The analysis was developed using the software for dynamic simulation of buildings called EnergyPlus, where was determined the annual consumption of electricity throughout the existing building as well as the consumption with lighting, electrical equipments and the HVAC system. The existing HVAC system represents 42% of total consumption and the heating corresponds to 89% of the total energy consumption of the HVAC system. The evaluation of thermal comfort zones of building were conducted with reference to the comfort zones of winter and summer from the ASHRAE Standard 55-2004. The thermal zones presented a percentage in the range of 7.6% to 33% of occupation hours outside the boundaries of ASHRAE thermal comfort zone (winter) evaluating the operating temperature. Based on simulation results of the existing building, changes were proposed in the envelope and in the use of a heat pump air conditioning system with VRF technology (variable refrigerant flow) to reduce the energy consumption of the HVAC and the number of hours outside the comfort zone. The use of double layers glasses with high transmissivity and surfaces colored with high solar absorption, wool glass in the external and double internal walls and EPS sheets on the building floor, presented excellent results. The modification of the envelope decreased 18.2 % in the total consumption of electricity and the HVAC system represents only 29.6% of the total energy of the building. After the building improvement was selected from catalogs of manufacturers, machines with VRF technology that could meet the maximum heat load between design days or weather file. The results obtained with the VRF system showed a 32.8% reduction on energy consumption of HVAC system and 9.3% about the total consumption of electricity of the building compared to a traditional heat pump air conditioning system with single speed compressor. With the improvement in the envelope and the use of VRF system the percentage of hours outside the ASHRAE comfort zones were lower than the 4% target set by the standard. The VRF system was modeled from model: Multi-Speed Electric DX Air Coil, of the EnergyPlus, for four different capacities of the compressor (60, 80, 100 and 120%) and for each capacity range were included the performance correlation of heating and cooling capacity, the correlations of electrical power heating and cooling for different condition of operate and correlation of the fraction of part load operation for each machine selected. As the study was conducted to the cooler regions of Brazil, defrost was considered in the simulation with reverse cycle for operating temperatures below 7°C. The heating energy with heat pump VRF presents lower specific cost compared to radiant systems like radiant floor and radiators.
225

Análise térmica e energética de uma edificação residencial climatizada com sistema de Fluxo de Refrigerante Variável -VRF Fernando Pozza

Pozza, Fernando January 2011 (has links)
O trabalho apresenta uma análise térmica e energética de uma edificação localizada na zona bioclimática 1, que compreende as cidades mais frias do Brasil. A análise foi desenvolvida com o auxílio do programa de simulação dinâmica de edificações EnergyPlus em que foi determinado o consumo anual de energia elétrica de toda a edificação existente, bem como o consumo do sistema HVAC (Aquecimento, Ventilação e Ar Condicionado) do tipo split com ciclo reverso. O sistema HVAC existente representa 42% do consumo total de energia elétrica da edificação sendo que o aquecimento totaliza 89% do consumo do sistema HVAC. A avaliação do conforto térmico dos ambientes climatizados da edificação foi realizada tendo como referência as zonas de conforto de inverno e de verão definidas pela ASHRAE Standard 55-2004. Os ambientes apresentaram um percentual de 7,6 % a 33% das horas de operação do sistema HVAC fora da zona de conforto térmico de inverno da ASHRAE, considerando somente a temperatura operativa. A partir dos resultados da simulação da edificação existente foram propostas modificações na envoltória e o uso de um sistema de ar condicionado com tecnologia VRF (fluxo de refrigerante variável) a fim de reduzir o consumo de energia pelo HVAC e o número de horas desconfortáveis. A utilização de vidros duplos de maior transmissividade, superfícies com cores de maior absortividade solar, lã de vidro nas paredes externas e internas duplas e placas de EPS (Poliestireno Expandido) no piso da edificação, apresentaram ótimos resultados, reduzindo o consumo total de energia elétrica em 18,2% e o consumo do sistema HVAC passou a representar apenas 29,6% do total de energia da edificação. Após o aprimoramento da edificação foram selecionadas, a partir de catálogos de fabricantes, as máquinas com tecnologia VRF que atendessem a máxima carga térmica entre os dias de projeto ou arquivo climático sob determinadas condições. Os resultados obtidos com o sistema VRF apresentaram uma redução de 32,8% sobre o consumo de energia do sistema de HVAC e de 9,3 % sobre o consumo total de energia elétrica da edificação quando comparado com um ar condicionado tradicional do tipo split. Com a melhoria na envoltória e o uso da tecnologia VRF para climatização o percentual de horas fora das zonas de conforto da ASHRAE foram menores que os 4% estabelecido pela norma, quando considerado a temperatura operativa. O sistema VRF foi simulado adaptando o módulo de simulação de serpentinas de expansão direta com compressores de velocidade variável, do EnergyPlus, para quatro faixas de capacidades distintas do compressor (60%, 80%, 100% e 120%) e para cada faixa foram inseridas as correlações de desempenho da capacidade e potência elétrica de aquecimento e refrigeração para diferentes condições de operação. Nas simulações foram considerados a perda de desempenho e o consumo elétrico para a operação de degelo com ciclo reverso para temperaturas externas inferiores a 7º C. As simulações com o sistema VRF acoplado a edificação comprovam a capacidade de economizar energia elétrica, além de apresentar o menor custo especifico da energia para aquecimento em relação aos sistemas radiantes. / This dissertation presents the thermal and energetic analysis of a building located in the bioclimatic zone 01, which comprises the coldness regions of Brazil. The analysis was developed using the software for dynamic simulation of buildings called EnergyPlus, where was determined the annual consumption of electricity throughout the existing building as well as the consumption with lighting, electrical equipments and the HVAC system. The existing HVAC system represents 42% of total consumption and the heating corresponds to 89% of the total energy consumption of the HVAC system. The evaluation of thermal comfort zones of building were conducted with reference to the comfort zones of winter and summer from the ASHRAE Standard 55-2004. The thermal zones presented a percentage in the range of 7.6% to 33% of occupation hours outside the boundaries of ASHRAE thermal comfort zone (winter) evaluating the operating temperature. Based on simulation results of the existing building, changes were proposed in the envelope and in the use of a heat pump air conditioning system with VRF technology (variable refrigerant flow) to reduce the energy consumption of the HVAC and the number of hours outside the comfort zone. The use of double layers glasses with high transmissivity and surfaces colored with high solar absorption, wool glass in the external and double internal walls and EPS sheets on the building floor, presented excellent results. The modification of the envelope decreased 18.2 % in the total consumption of electricity and the HVAC system represents only 29.6% of the total energy of the building. After the building improvement was selected from catalogs of manufacturers, machines with VRF technology that could meet the maximum heat load between design days or weather file. The results obtained with the VRF system showed a 32.8% reduction on energy consumption of HVAC system and 9.3% about the total consumption of electricity of the building compared to a traditional heat pump air conditioning system with single speed compressor. With the improvement in the envelope and the use of VRF system the percentage of hours outside the ASHRAE comfort zones were lower than the 4% target set by the standard. The VRF system was modeled from model: Multi-Speed Electric DX Air Coil, of the EnergyPlus, for four different capacities of the compressor (60, 80, 100 and 120%) and for each capacity range were included the performance correlation of heating and cooling capacity, the correlations of electrical power heating and cooling for different condition of operate and correlation of the fraction of part load operation for each machine selected. As the study was conducted to the cooler regions of Brazil, defrost was considered in the simulation with reverse cycle for operating temperatures below 7°C. The heating energy with heat pump VRF presents lower specific cost compared to radiant systems like radiant floor and radiators.
226

Imagens em movimento e arquitetura : transformações de uma tipologia arquitetônica e edifícios de cinema de Santa Maria - RS / Motion pictures and architecture : transformations of an architectural typological and the Santa Maria's cinemas theater

Mayer, Luara Soares January 2015 (has links)
A arquitetura desempenha papel fundamental na história do cinema, participando ativamente no percurso que torna essa inovação tecnológica no entretenimento mais consumido do século XX no mundo ocidental. Diante disso, este trabalho propõe-se a compor um estudo sobre as transformações da tipologia arquitetônica das edificações destinadas à exibição cinematográfica do Rio Grande do Sul e de Santa Maria, analisando-as dentro do contexto histórico e disciplinar mundial, de modo a vincular e identificar a filiação da história e realidade locais com a história e o movimento globais da cultura e da arquitetura. A revisão se estrutura a partir de uma abordagem do cinema sucessivamente como técnica, espetáculo e indústria, e como arquitetura, definindo uma das tipologias mais representativas do século XX. Como arquitetura, cada tipo é documentado e ilustrado em suas referências, precedentes e exemplares relevantes, com enfoque na análise arquitetônica dos edifícios locais, especialmente de Porto Alegre e da cidade de Santa Maria. Após as análises, é apresentado um conjunto de características identificadas como definidoras do tipo tratado, reunindo material analítico objetivo a respeito de cada período arquitetônico. Como encerramento, uma avaliação da situação atual dos edifícios de cinemas permite esboçar algumas perspectivas sobre o seu futuro. Para encerrar o ciclo das transformações arquitetônicas a que esses edifícios foram submetidos até o momento, foi desenvolvida uma complementação histórica a respeito da ocupação dos edifícios de cinema de Santa Maria após o encerramento de suas atividades, fortalecendo o enfoque de preservação da memória cultural local a que se propôs a dissertação. / Architecture has been a key factor in the history of cinema, playing a major role in this technology becoming the western world’s most consumed form of entertainment in the 20th century. Therefore, this paper will examine the transformation of architectural typology of buildings designed for the exhibition of cinema within Rio Grande do Sul and Santa Maria. Further, it will analyse them in a worldwide historic and disciplinary context, in such a way as to identify the local history, with reference to global history as well as the evolution of culture and architecture. The paperbegins by sequentially defining cinema as a technique, spectacle, industry, and, as architecture, defining one of the most representative typologies of the 20th century. As architecture, each type is documented and shown in its references, precedents and meaningful examples, focusing on the architectural analysis of local buildings, particularity in the cities of Porto Alegre and Santa Maria. Following these analyses, identifiable characteristics for each of the selected types are presented, gathering objective analytical material about each architectonic period. As closure, an appraisal of current movie theater buildings allows for the outliningof possibilities their future situation. To complete the architectonic transformation cycle until now, a historic supplement was developed regarding the use of the Santa Maria movie theater buildings beyond the conclusion of their exhibition activities, focusing on the preservation of historical local culture, for which this dissertation was proposed.
227

Cidade e universidade : arquitetura e configuração urbana do Campus Centro da UFRGS

Tonioli, Renata Manara January 2014 (has links)
A Universidade Federal do Rio Grande do Sul (UFRGS) possui sua estrutura física, em Porto Alegre, organizada em quatro campi: Campus Centro, Campus Saúde, Campus Olímpico e Campus do Vale. Núcleo original da instituição, o Campus Centro se localiza em região central da cidade e é composto por dois quarteirões contíguos. Com a forma de um polígono, o campus possui um conjunto edificado heterogêneo formado por prédios construídos entre os anos de 1898 e 2013. Antes mesmo de serem agrupadas para formar a Universidade de Porto Alegre (UPA) em 1934, as escolas autônomas de ensino superior de espírito positivista fundadas no final do século XIX já possuíam suas sedes implantadas nos dois quarteirões. Federalizada em 1951, a UFRGS ali mantém prédios de importantes unidades de ensino, além da sede da instituição. O conjunto edificado reúne exemplares com características das arquiteturas eclética e modernista, reconhecidos como patrimônio cultural a nível institucional, nos âmbitos municipal, estadual e nacional. A configuração do campus possui relação direta com a evolução urbana da cidade, respondendo aos diversos processos de constituição de sua estrutura urbana e suas circunstâncias históricas, socioeconômicas e ambientais. Quando os primeiros edifícios foram construídos, por volta de 1900, o núcleo urbano de Porto Alegre se restringia à ponta da península, e a região do campus apresentava-se como um descampado, fora dos limites da cidade. Com o crescimento e desenvolvimento da cidade, o núcleo urbano sofreu grande expansão, e a área antes periférica, poucas décadas depois já fazia parte do conturbado centro da capital. A presente dissertação pretende investigar a origem e o desenvolvimento do Campus Centro da UFRGS, assunto que até o presente momento não possui estudos consistentes. Abordando tanto as questões de configuração urbana relacionadas ao espaço dos dois quarteirões do Campus Centro quanto as questões específicas relativas à arquitetura das edificações e do espaço aberto que os compõe, o estudo busca contribuir para a documentação e o conhecimento do tema. / The Federal University of Rio Grande do Sul (UFRGS) has, in Porto Alegre, a multi campi structure composed of the Downtown Campus, Health Campus, Olympic Campus and Valley Campus. UFRGS Downtown Campus, which is the foundational core of the institution, is located in Porto Alegre’s central district and is composed by two contiguous city blocks. Conformed like a polygon, the campus is composed by an heterogeneous set of buildings made between 1898 and 2013. Even before being assembled to create Porto Alegre University (UPA) in 1934, 19th century positivism orientated autonomous colleges were already located over these blocks. After its federalization on 1951, UFRGS still holds several important faculty buildings there, other than its head offices. The set of buildings on the Downtown Campus is composed by exemplars with features of the eclectic and modernist architectures, recognized as cultural heritage institutional, at municipal, state and national levels. Campus configuration holds close relation with city’s urban development, responding to distinct processes of its urban structure generation and historical, socioeconomical and environmental circumstances. When the first colleges where built, around 1900, Porto Alegre’s urban area was restricted to the peninsula’s site, and the university blocks where part of an unoccupied zone outside city limits. With city’s growth and development, the urban core has undergone extensive expansion and the area, once peripheral region, some decades later was part of the troubled center of the capital. This work aims to deal with the origin and development of the Central Campus of UFRGS, subject until now has no consistent studies. Addressing both the issues of urban configuration related to space two city blocks as the specific issues relating to the architecture of the buildings and the open space, the study seeks to contribute to the documentation and knowledge of the topic.
228

Buenos Aires de Bonet : Antonio Bonet Castellana, habitação coletiva e o projeto da cidade moderna, 1943-1956

Bender, Helena January 2014 (has links)
Sabe-se que o arquiteto catalão Antonio Bonet Castellana é reconhecido por suas obras na costa uruguaia, sendo a urbanização de Punta Ballena, e o conjunto de casas, de grande importância para a Arquitetura Moderna no sul da América Latina. Contudo, este trabalho entende que a atuação de Bonet no continente, sobretudo em relação a sua contribuição urbanística, não pode ser compreendida apenas através de tal obra, e visa complementar essa perspectiva. Assim, em vez da uruguaia Punta Ballena, é a cidade não construída em Buenos Aires, na Argentina, que se pretende investigar. Para tanto, esta dissertação analisa os projetos não construídos de conjunto habitacional para Casa Amarilla (1943), o bairro proposto em Bajo Belgrano (1948-49) e a remodelação de Barrio Sur (1956), pensados para tal cidade, reconhecendo-os como uma série. O intuito deste estudo é o de melhor conhecer a atuação de Bonet, sua contribuição ao projeto da cidade moderna e às soluções de habitação coletiva que dela derivam. Também é intenção do trabalho compreender as relações entre a cidade pensada por Bonet e a cidade que existe, colaborando para um estudo mais detalhado sobre a cidade da Arquitetura Moderna. / It is known that the Catalan architect Antonio Bonet Castellana is recognized for his masterpiece work in the Uruguayan coast, which include the Punta Ballena settlement and a set of houses – of great importance to the Modern Architecture in South America. Nonetheless, this text assumes that Bonet’s contribution on modern urbanism cannot be fully understood only through such work and aims to complement that statement. Thus, instead of the built Punta Ballena it is the unbuilt city in Buenos Aires, Argentina, that this text intends to investigate.Therefore, this dissertation analyzes the unbuilt projects of Casa Amarilla housing (1943), Bajo Belgrano neighborhood (1948-49) and Barrio Sur quarter (1956), conceived for the city of Buenos Aires, recognizing them as a series. It is intended to investigate Bonet’s design and his contribution to the modern city project, including its solutions of collective housing. It is also an intention to understand the relationship between the city planned by Bonet and the existing one, collaborating on a more detailed study about the city of the Modern Architecture. / Es sabido que el arquitecto catalán Antonio Bonet Castellana es reconocido por sus obras en la costa uruguaya, siendo la urbanización de Punta Ballena, y el conjunto de casas, de gran importancia para la Arquitectura Moderna en el sur de Latinoamérica. Sin embargo, esta disertación entiende que la actuación de Bonet en el continente, sobre todo con relación a su contribución urbanística, no puede ser comprendida solamente a través de tal obra, y procura complementar dicha perspectiva. Así, en vez de la uruguaya Punta Ballena, es la ciudad no construida en Buenos Aires, Argentina, que se pretende investigar. De esta forma, el texto analiza los proyectos no construidos del conjunto residencial en Casa Amarilla (1943), el barrio propuesto en Bajo Belgrano (1948-49) y la remodelación de Barrio Sur (1956), pensados para tal ciudad, reconociéndolos como una serie. La finalidad de este estudio es conocer mejor la obra de Bonet, su contribución al proyecto de la ciudad moderna y las soluciones de vivienda colectiva que de ella derivan. También es objetivo del trabajo comprender las relaciones entre la ciudad pensada por Bonet y la ciudad existente, colaborando para un estudio más detallado sobre la ciudad de la Arquitectura Moderna.
229

Construções verdes : estudo comparativo sobre as categorias de "certificação verde" de acordo com os critérios estabelecidos pela Green Building Council Brasil

Marcos Antonio Cuba 17 December 2010 (has links)
O conceito de construção verde não está atrelado unicamente à preservação do meio ambiente, visto que muitos pesquisadores empregam usualmente o termo construção sustentada, que é mais condizente com a proposta que prevê o desenvolvimento econômico, social e o respeito ao meio ambiente. Em relação a países em desenvolvimento como o Brasil, equilibrar esses três pontos é essencial para assegurar um crescimento econômico sólido e sustentável. Neste contexto, em decorrência da necessidade de construções menos impactantes ao meio ambiente, foi criado nos Estados Unidos o Conselho Nacional de Construções Verdes, órgão regulamentador das normas de construção e certificador daquelas que atendam as normas mundiais. Essa certificação foi criada buscando diminuir o consumo na fabricação de materiais, manutenção de prédios e gestão de resíduos. O presente estudo visa analisar e aprimorar os conhecimentos relativos à certificação das denominadas edificações sustentáveis no Brasil, analisando as suas características, vantagens para o meio ambiente e para sociedade presente e futura. Além disso, buscou-se apontar as etapas necessárias para se lograr êxito na certificação verde de um empreendimento no Brasil, levando-se em consideração os critérios estabelecidos pelo Green Building Council Brasil, órgão oficialmente credenciado a concedê-la àqueles que implementem os requisitos necessários. Essa demonstração foi feita por meio de estudo comparativo entre dois empreendimentos certificados: o primeiro, Eldorado Business Tower, obteve a certificação denominada Platinum (máxima), e o segundo, Edifício Cidade Nova, que obteve logrou a certificação verde denominada Certified (mínima). O resultado da análise demonstrou que, apesar dos obstáculos culturais e econômicos encontrados para a implementação de uma edificação certificada, a prática parece demonstrar que o resultado final é semelhante ao investimento em edificações convencionais. No entanto, a procura pelo selo vem aumentando exponencialmente a cada ano, demonstrando que os antigos paradigmas começam a ser derrubados, em benefício do meio ambiente, que possa garantir as presentes e futuras gerações. / Concept of construction green not is joined solely to preservation of environment, since many researchers usually use the term supported, that is more in accordance with the proposal that the development foresees economic, social construction and the respect to the environment. In relation the developing countries as Brazil, to balance these three points are essential to assure a solid and sustainable economic growth. In this context, in result of the necessity of less impacts constructions to the environment, it was created in the United States the National Advice of Green Constructions, prescribed agency of the construction norms and certifier of whom they take care of the world-wide norms. This certification was created searching to diminish the consumption in the manufacture of materials, maintenance of building and management of residues. The present study it aims at to analyze and to improve the relative knowledge to the certification of the called sustainable constructions in Brazil, being analyzed its characteristics, advantages for the environment and present and future society. Moreover, one searched to point the stages necessary to cheat success in the green certification of an enterprise in Brazil, taking itself in consideration the criteria established for the Green Building Council Brazil, officially credential agency to grant it those to it that implement the necessary requirements. This demonstration was made by means of comparative study between two certified enterprises: the first one, Eldorado Business Tower, got the called certification Platinum (maximum), and as, Building New City, that it got cheated the green certification called Certified (minimum). The result of the analysis demonstrated that, although found the cultural and economic obstacles for the implementation of a certified construction, the practical one seems to demonstrate that the final result is similar to the investment in conventional constructions. However, the search for the stamp comes exponentially increasing to each year, demonstrating that the old paradigms start to be knocked down, in benefit of the environment, that can guarantee the gifts and future generations.
230

Resíduos de poli (tereftalato de etileno) e de pneu na confecção de pisos flutuantes para o isolamento do ruído de impacto / Poly (ethylene-terephthalate) and tyre residues in floating floors for impact sound insulation

CARVALHO, Maria Luiza de Ulhoa 21 August 2009 (has links)
Made available in DSpace on 2014-07-29T15:01:51Z (GMT). No. of bitstreams: 1 dissertacao maria luiza.pdf: 3132447 bytes, checksum: e48de2cde6494677cafaf830a4ead4f5 (MD5) Previous issue date: 2009-08-21 / The demographic growth has created a gain in urban solid waste that deteriorates the citizen s quality of life. High buildings represent the main way for accommodations in big cities for these growing urban populations. However, impact sound insulation has shown itself quite poor. In order to propose an alternative way of minimization to the two problems, residue generation and impact noise, this study aimed to investigate the viability of using poly (ethylene-terephthalate) - PET and rubber tire residues for impact sound insulation in floating floors. Plates of 1 m² with thickness of 1.5 and 2.5 cm to 1:4 and 1:5 (ciment:residue) ratios were molded for the acoustic experiments, as well as portable mortar slabs covered with high and popular quality floor coverings. The main methods used were ISO 140-7 (1998) for measuring the standardized impact sound pressure level, L nT, in one-third-octave bands and ISO 717-2 (1996) to calculate the weighted standardized impact sound pressure level, L nT,w. Both residues presented high sound insulation in relation to their references. It was observed that the results for the PET specimen were superior to those of the rubber tires residue. However, the results among the residues presented different tendencies as their ratio changed. While the impact sound insulation of the rubber tires samples decreased with the increase of residue, PET samples presented more insulation with residue increase. Another observed factor was that the high quality floor covering presented a significant superior impact sound isolation compared to the popular floor covering. Considering all results, it is possible to conclude that the use of the studied residues in floating floors contributes to impact sound insulation / O crescimento demográfico mundial tem criado um aumento na geração de resíduos sólidos urbanos e deteriorado a qualidade de vida dos cidadãos. As edificações altas se apresentam como a principal forma de acomodação da crescente população nas cidades, no entanto, o conforto sonoro em relação ao ruído de impacto tem se mostrado precário. Com o intuito de propor uma alternativa de minimizar ambos os problemas, a geração de resíduos e o ruído de impacto, a presente pesquisa teve como principal objetivo estudar a viabilidade de uso dos resíduos de poli (tereftalato de etileno) - PET e do pneu inservível na confecção de pisos flutuantes no isolamento do ruído de impacto. Placas de 1 m² com traço 1:4 e 1:5 (cimento:resíduo) nas espessuras de 1,5 e 2,5 cm foram moldadas para realizar os ensaios acústicos, assim como placas de argamassa armada revestida com cerâmica popular e de alto padrão. As principais metodologias utilizadas foram a ISO 140-7 (1998) para obter o nível de pressão sonora de impacto padronizada por bandas de terças de oitavas, L nT, e a ISO 717-2 para ponderar o valor único do nível de pressão sonora de impacto padronizado e ponderado, L nT,w. Ambos resíduos apresentaram isolamento superior em relação às respectivas referências. Observou-se que o isolamento do ruído de impacto das amostras com PET foi superior às com pneu. No entanto, os resultados entre os resíduos apresentaram tendências diferentes com a mudança do traço. Enquanto que o isolamento das amostras do pneu decaiu com o acréscimo do resíduo, as amostras com PET tiveram um ganho maior com o aumento do resíduo. Outro fator observado foi que o contrapiso com cerâmica de alto padrão apresentou um efeito significativo do isolamento em relação à cerâmica popular. Em vista de todos os resultados pode se concluir que é viável a utilização dos resíduos estudados na confecção de pisos flutuantes para o isolamento do ruído de impacto

Page generated in 0.0588 seconds