• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 268
  • 196
  • 13
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 486
  • 404
  • 209
  • 171
  • 95
  • 94
  • 87
  • 81
  • 70
  • 47
  • 46
  • 42
  • 37
  • 33
  • 32
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Ferramenta de autoavaliação do potencial de eficiência energética aplicada às indústrias do setor metalmecânico

Daniel Corteletti 01 October 2015 (has links)
Dada a importância dos recursos energéticos nos processos das indústrias de manufatura metalmecânica, e frente ao elevado custo dos insumos energéticos, torna-se fundamental a constante prospecção de oportunidades para redução de desperdício e aumento do aproveitamento da energia adquirida. A diversidade dos fatores relacionados a estas possíveis oportunidades dificulta a análise e identificação das prioridades. Neste trabalho, propõe-se a elaboração de uma ferramenta de auxílio ao diagnóstico de eficiência energética, cuja construção é dividida em 3 fases: identificação dos fatores e das dimensões de análise e oportunidades de aumento da eficiência energética descrita pela literatura; elaboração de um conjunto de questões diagnósticas; proposição do mecanismo de autoavaliação para identificação de oportunidades na empresa analisada. Após a aplicação da ferramenta proposta, conclui-se que a identificação de oportunidades de eficiência energética pode ser realizada transportando-se a percepção dos especialistas para uma ferramenta de autoavaliação, sugerindo-se a continuidade e aprimoramento nos estudos aqui realizados.
202

Modelagem completa e análise dos recursos energéticos do lado da demanda para o PIR. / Modelling and assessment of demand side energy resources in the integrated resources planning process.

Baitelo, Ricardo Lacerda 02 March 2006 (has links)
Esta dissertação propõe um modelo de caracterização de recursos energéticos do lado da demanda que pretende abranger todos os tipos de ações e medidas referentes ao gerenciamento da demanda e à conservação energética, avaliando-as de forma holística, dentro de quatro dimensões: técnico-econômica, ambiental, social e política. Os recursos considerados na composição do modelo são submetidos às fases de Inventário de Recursos Energéticos do Lado da Demanda, Caracterização das Dimensões e Atributos de Avaliação de Recursos, Formulação dos Potenciais Energéticos e Aplicação do Modelo em Caso Piloto. O Inventário de Recursos Energéticos do Lado da Demanda pretende levantar, descrever e segmentar todas as alternativas energéticas de GLD e setores de consumo energético. A Caracterização da Avaliação de Recursos delimita as esferas de análise de recursos e a caracterização de seus atributos quanto a custos e benefícios provenientes de seu emprego. A Formulação dos Potenciais Energéticos define seu cálculo a partir de sua amplitude e restrições gerais de aplicação. O modelo é aplicado em um estudo piloto, na Região Administrativa de Araçatuba, por meio de um exercício de formulação do PIR, considerando a utilização de ferramentas de Avaliação dos Custos Completos, Cálculo de Potenciais Energéticos e Elaboração de Cenários de Projeção do Consumo Energético para um horizonte de tempo determinado. / This work presents a model for the characterization and assessment of demand side energy resources, which intends to comprehend every kind of action or measure related to demand side management and energy conservation, evaluated thouroughly into four dimensions: technical-economical, environmental, social and political. The resources included in the composition of the model are subjected to the stages of Inventary of Demand Side Resources, Characterization of Dimensions and Attributes of the Resources Assessment, Formulation of Energy Potentials and Model Application on a Real Case Study. The Inventary of Demand Side Resources intends to enlist, describe and segment all demand side management energy alternatives and their application in different economy sectors. The Characterization of the Resources Assessment defines the spheres of the assessment of resources and the characterization of its attributes as for costs and benefits resulting from their utilization. The Formulation of Energy Potentials defines their accounting based on their range and general application restrictions. The Model is applied in a case study, in the Administrative Region of Araçatuba, through an exercise of IRP formulation, regarding the utilization of Full Cost Accounting, Energy Potentials Accounting and Scenarios of Energy Consumption for a determined horizon.
203

Carvão vegetal e siderurgia: de elo perdido a solução para um mundo pós-Kyoto / Charcol based iron & steelmaking: from primitive technological model to solution for a post-Kyoto world

Silva, Thiago Fonseca Morello Ramalho da 18 November 2009 (has links)
Em um mundo cada vez mais temeroso do aquecimento global, o balanço de carbono favorável da siderurgia brasileira a carvão vegetal coloca esta modalidade em evidência após um passado à sombra da grande siderurgia a combustível fóssil. Esta posição de destaque é posta em cheque pelo espectro do desmatamento, mesmo já sendo realidade a certificação de plantações arbóreas que substituam a biomassa florestal e a concessão de créditos de carbono pelo emprego de tecnologias de carbonização de baixo impacto ambiental. Porque o modelo de cultivo e aproveitamento máximo da biomassa encontra resistência para se massificar na siderurgia a carvão vegetal de Minas Gerais, segmento que originalmente o concebeu? O exame crítico da história da produção e do consumo do carvão vegetal em tal estado conduz a uma resposta cujo fundamento repousa sob a maneira pela qual as empresas do segmento destacado alocaram seu capital. A balança por elas utilizada para pesar as aplicações possíveis opôs sistematicamente duas perdas, incertas por natureza. De um lado, a perda referente à possibilidade do estoque de florestas vir a se manifestar enquanto fator limitante às atividades siderúrgicas. De outro, a perda imposta pelo desvio, para a formação de plantações, do capital direcionado a aplicações comumente acessadas em sua trajetória individual de acumulação de capital. As siderúrgicas mineiras a carvão vegetal agiram como se entre elas fosse predominante a concepção de que a magnitude desta última perda seria superior à magnitude da primeira. Analisa-se, no último capítulo, o fomento florestal enquanto uma saída para romper com essa concepção. Demonstra-se que as economias de escala não são uma condição necessária da produção de lenha de eucalipto e do carvoejamento, comprovando-se que estes arranjos, caracterizados pelo compartilhamento de custos e riscos entre siderúrgicas e proprietários rurais, podem ser mutuamente vantajosos do ponto de vista pecuniário. / In a global-warming-frightened world, the positive carbon balance of charcoal-based iron & steel making recovers it from a past outshined by the dominance of the large fossil fuel mills. Nevertheless, the risk of not being able to profit from the global decarbonization consensus is material, owing to the dependency on deforestation. This is true even being that the certification of forest-biomass-substituting-arboreal plantations and the concession of carbon credits to low environmental impact carbonization technologies, are already concrete possibilities. Why the model of cultivation and optimal use of biomass has not become dominant among the charcoal based iron & steel mills of Minas Gerais, the industry that has originally conceived it? The answer to which the critical exam of the history of charcoal production and consumption in Minas Gerais state points out is that a non-permissive behavioral principle has predominated among the sectors enterprises. Its the conception that the loss imposed by the outcome where the forest stock becomes a limiting factor for iron & steel making is smaller than the loss imposed by the deviation, to biomass cultivation, of the resources generally directed to traditional capital accumulation opportunities. The forest farmer contract, as a way to break with this conception, is evaluated in the last chapter. The fact that economies of scale are not a necessary condition of eucalyptus plantation and charcoal making is demonstrated, what shows that such arrangements, characterized by the sharing of cost and risk between mills and farmers, can be mutually advantageous from a pecuniary standpoint.
204

Diseño de sistema de cogeneración para centro comercial utilizando gas natural

Santana Canchanya, Dennys Jesús 13 June 2011 (has links)
El tema de tesis desarrollado tiene como objetivo diseñar un sistema de cogeneración para satisfacer los requerimientos de electricidad y aire acondicionado en un Centro Comercial de la ciudad de Lima, que en la actualidad cubre sus requerimientos exclusivamente con energía eléctrica proveniente de una empresa generadora. Para diseñar la Instalación de Cogeneración, primero se evaluó la situación actual energética del Centro Comercial basado en información técnica y estadística de los últimos años. Se logró establecer que la demanda de potencia máxima de electricidad requerida para cubrir cargas de iluminación y fuerza motriz durante todo el año es de 7,7 MW, mientras la carga térmica máxima para climatización a cubrir en los meses de altas temperaturas (estación de verano) es de 6,6 MW. Definido los requerimientos energéticos se realizó un estudio comparativo entre motores de combustión interna y turbinas a gas natural con el objetivo de seleccionar la mejor tecnología que se adapte a los requerimientos técnicos y económicos del Centro Comercial. La selección de la tecnología adecuada se realizó mediante una simulación de la instalación operando con ambas tecnologías, realizando una evaluación basado en criterios técnicos, económicos y ambientales, se optó por seleccionar a los motores de combustión interna que presentan mejor comportamiento frente a las turbinas a gas natural. Para cubrir la demanda térmica por climatización elegimos maquinas de absorción, de ciclo de doble efecto a vapor, que permiten aprovechar las energías residuales de forma más eficiente que el ciclo de simple efecto. La recuperación de energías residuales de los motores se logra con intercambiadores de calor y calderas de recuperación, esta ultima cada una con su respectivo economizador que van conectadas a un motor de combustión. La Instalación de Cogeneración diseñada, cubre de forma total los requerimientos de electricidad y aire acondicionado demandados por el Centro Comercial, por ende es viable técnicamente. A efectos de realizar el estudio económico se realizó la evaluación que involucra la inversión inicial y costo de operación de la planta durante todo el año, que engloba los costos por combustible, mantenimientos de equipos e instalaciones, costo de personal encargado de la operación de la instalación. La inversión inicial requerida para la instalación de cogeneración asciende a la suma de US$ 10,384,871. Diseñada la instalación de Cogeneración se realizó la identificación y evaluación de los potenciales impactos positivos y negativos del proyecto sobre el medio ambiente, utilizando la técnica de encadenamiento secuencial o diagrama de redes. Se desarrollo programas para prevenir, mitigar y/o eliminar los impactos negativos, y maximizar los positivos, en las etapas de construcción operación y cierre. Por último se realizó la evaluación económica del proyecto, mediante el análisis de viabilidad económica de la Instalación de Cogeneración en las condiciones actuales que operaría para cubrir los requerimientos del Centro Comercial. Los resultados de los indicadores de rentabilidad económica muestran un VAN negativo, y un TIR muy inferior al valor de la tasa de descuento considerada. Estos resultados muestran que en condiciones actuales no es viable económicamente el proyecto de instalación de cogeneración. Realizando un análisis de sensibilidad el proyecto es viable económicamente si los requerimientos térmicos del Centro Comercial aumentan de tal manera que se pueda aprovechar al máximo las energías residuales mediante la venta de energía en forma de vapor y agua caliente, se accedan a precios más competitivos de gas natural como el caso de generadores eléctricos y el precio del gas natural no sufra incrementos por encima del 4% anual. / Tesis
205

Avaliação do regime operacional semi-contínuo em fermentador anaeróbico para a produção de hidrogênio e ácidos graxos voláteis utilizando glicerol como substrato

Silva, Maria Cristina de Almeida January 2017 (has links)
O presente trabalho teve como objetivo principal a avaliação do regime operacional semicontínuo para a produção de hidrogênio e ácidos graxos voláteis, utilizando glicerol como substrato e inóculo misto. Em um teste preliminar em batelada, foi avaliado o potencial de produção de hidrogênio deste substrato, comparando com sacarose, utilizando inóculo natural e direto. Foram verificados resultados satisfatórios, com parâmetros de desempenho semelhantes e até superiores aos obtidos com sacarose, quando utilizada a inoculação direta. Sendo assim, dois reatores semi-contínuos foram operados durante 132 dias, empregando biomassa suspensa, e glicerol nas concentrações de 10 e 50 g/L. O inóculo empregado foi oriundo de reator anaeróbio, submetido a tratamento térmico. Para comparação dos resultados dos reatores semi-contínuos, outros dois reatores foram operados de forma contínua, durante 62 dias, sob as mesmas condições já descritas, exceto pela presença de meio suporte para aderência da biomassa. O tempo de detenção hidráulico testado foi 1 d em ambos os regimes operacionais propostos, sendo e o tempo de detenção celular dos reatores semi-contínuos de 1,5 d. Os indicadores de desempenho avaliados foram eficiência de conversão do substrato, volume, produtividade e rendimento de hidrogênio, bem como distribuição mássica de ácidos graxos voláteis e grau de acidificação. Também foi verificada a diversidade microbiana nos reatores semi-contínuos e contínuos. Os principais ácidos graxos formados nos reatores semicontínuos foram acético e butírico, e nos contínuos, propiônico. No início do experimento, foi verificada elevada produção de biogás e hidrogênio nos reatores semi-contínuos, com queda dos valores no decorrer do teste, sendo mais pronunciada no reator com maior concentração afluente de glicerol. Já os reatores contínuos, desde o início do teste, apresentaram baixa produção de gás, o que consequentemente resultou em baixíssimos valores de rendimento e produtividade de hidrogênio. Os reatores semi-contínuos apresentaram satisfatória produtividade volumétrica quando a menor concentração de glicerol foi empregada, alcançando o valor máximo de 2928 mL H2/L.d, e baixo rendimento, em torno de 0,1 mol H2/mol glicerol. Foi possível associar a elevada produção hidrogênio e ácidos graxos voláteis nos reatores semi-contínuos com o gênero Enterobacter. Já a baixa produção foi vinculada ao gênero Clostridium. Nos reatores contínuos, foi verificada a influência da família Veillonellaceae (Pectinatus), que são produtores de ácido propiônico. / The purpose of the present work was to evaluate the semi-continuous operational regime for production of hydrogen and volatile fatty acids, using glycerol as substrate and mixed inoculum. The hydrogen production potential from glycerol was evaluated by a preliminary batch test using natural and direct inoculum, and the results were compared with sucrose. Satisfactory hydrogen production results from glycerol were observed when direct inoculation was used, with similar and even better values when compared to sucrose. Two semi-continuous reactors were operated, during 132 days, with suspended biomass and glycerol at concentrations of 10 and 50 g/L. The inoculum was from an anaerobic reactor, submitted to thermal treatment. Two other reactors were operated continuously for 62 days as a comparison for the results of the semi-continuous reactors. The same conditions were applied, except for the presence of support medium for biomass adherence. The hydraulic detention time tested was 1 d in both operating regimes, and the semi-continuous reactors cell detention time was 1.5 d. The evaluated performance indicators were substrate conversion efficiency, volume and hydrogen yield, as well as mass distribution of volatile fatty acids and acidification degree. Microbial diversity was also evaluated in semi-continuous and continuous reactors. The main fatty acids formed were acetic and butyric in the semicontinuous, and propionic in the continuous reactors. There was a high production of biogas and hydrogen in the semi-continuous reactors at the beginning of the experiment, with rates dropping during the test, mainly in the reactor with higher affluent glycerol concentration. The continuous reactors presented low gas production from the beginning of the test, which resulted in extremely low values of hydrogen yield. The semi-continuous reactors presented satisfactory volumetric productivity when the lowest concentration of glycerol was used, reaching a maximum value of 2928 mL H2/L.d, and low yield, around 0.1 mol H2 / mol glycerol. It was possible to associate the high production of hydrogen and volatile fatty acids in the semi-continuous reactors with the genus Enterobacter. The low hydrogen production was related to the genus Clostridium. The continuous reactors were influenced by the presence of Veillonellaceae (Pectinatus) family, which are propionic acid producers.
206

Demanda energética em situação simulada de luta em atletas de taekwondo / Energy demands in taekwondo athletes during combat simulation

Campos, Fábio Angioluci Diniz 02 September 2011 (has links)
O objetivo deste estudo foi investigar as contribuições dos sistemas energéticos e do gasto energético total em situação de luta. A amostra foi composta de 10 atletas do sexo masculino de nível nacional/internacional (21±6 anos; 176.2±5.3cm; 67.2±9.0kg), competindo em nível internacional. Para a estimativa das contribuições energéticas e do gasto energético total, foram realizados três protocolos simulando combate (um round, dois rounds e três rounds). As lutas foram filmadas para quantificação das ações motoras em cada round. A estimativa dos sistemas energéticos aeróbio (WAER), anaeróbio alático (WPCR) e anaeróbio lático (W[La-]) foi realizada através do consumo de oxigênio durante a atividade, do delta da concentração sanguínea de lactato de cada round e do débito alático de oxigênio (DAO2), respectivamente. A razão entre as ações de elevada intensidade e momentos de baixa intensidade (step e pausa) no protocolo 3 foi ~1:7. Os resultados dos sistemas WAER, WPCR e W[La-] no protocolo 3 foi 120±22kJ (66±6%), 54±21kJ (30±6%), 8,5kJ (4±2%), respectivamente. Assim, as sessões de treinamento devem ser direcionadas principalmente para a melhoria do sistema anaeróbio alático (responsável pelas ações de alta intensidade), e do sistema aeróbio (responsável pelo processo de recuperação entre as ações de alta intensidade) / The purpose of this study was to investigate energy system contributions and energy cost in combat situation. The sample was constituted by 10 male taekwondo athletes at national/international level (age: 21±6 years old; height: 176.2±5.3cm; body mass: 67.2±9.0kg) competing at national/international level. To estimate the energy contributions and total energy cost of the fights, athletes performed a three different protocols simulated competition (1 round, 2 rounds and 3 rounds). The combats were filmed in order to quantify the actual time spent fighting in each round. The estimate of the aerobic (WAER), anaerobic alactic (WPCR) and anaerobic lactic (W[La-]) energy systems was carried out through the oxygen consumption during the activity, the fast component of excess post-exercise oxygen consumption, and the delta of blood lactate concentration in each round, respectively. The mean data between the high intensity actions and moments of low intensity (step and pause) was ~1:7. The results of WAER, WPCR and W[La-] system contributions were 120±22kJ (66±6%), 54±21kJ (30±6%), 8,5kJ (4±2%), respectively. Thus, training sessions should be directed mainly to the improvement of the anaerobic alactic system (responsible by the high-intensity actions), and of the aerobic system (responsible by the recovery process between high-intensity)
207

Alocação de equipamentos de controle de tensão em redes de distribuição considerando recursos energéticos distribuídos. / Sem título em inglês

Casillas Peña, German Israel 03 April 2017 (has links)
Nos atuais sistemas de distribuição de energia elétrica, podem ser aplicadas novas metodologias que consideram o comportamento em tempo real dos equipamentos, abrangendo cargas especiais como os veículos elétricos (VE) e sistemas de recursos energéticos distribuídos (RD). Neste trabalho se apresenta a revisão bibliográfica, que mostra a análise do desenvolvimento do planejamento dos sistemas de distribuição, seja da expansão e da operação, considerando as metodologias convencionais até as que abordam os RD\'s, concluindo que na atualidade não é possível analisar um sistema sem RD\'s e VE\'s e finalmente ter que operar um sistema com este tipo de geração e cargas na rede. O estudo das ferramentas de otimização permite determinar as técnicas a serem utilizadas. Este trabalho abrange duas, quais sejam, Busca em profundidade (depth-first search) e Algoritmos Genéticos, com objetivo de obter a alocação ótima dos reguladores de tensão, bancos de capacitores, conjuntamente com os sistemas fotovoltaicos e de armazenamento, que permitam manter a tensão dentro da faixa adequada estabelecida pela Agência Nacional de Energia Elétrica (ANEEL). A seguir, se apresenta a metodologia desenvolvida com os softwares utilizados, quais sejam, o OpenDSS para solução de fluxos de potência com recursos distribuídos e MATLAB para programar o algoritmo da metodologia desenvolvida. Os resultados nas redes teste IEEE de 13 barras e de porte real, denominada ckt5, mostram a importância de considerar a informação das curvas de carga e os perfis de geração dos recursos distribuídos dentro das metodologias, com objetivo de conseguir soluções de acordo com a realidade dos sistemas de distribuição. Logo após se apresentam as atividades futuras, que permitirão abranger aspectos dentro da função objetivo como os índices de tensão estabelecidos pela ANEEL, inserir outras fontes de geração como os sistemas eólicos e considerar os períodos dos estágios de planejamento dentro da metodologia desenvolvida, bem como as conclusões, referências bibliográficas e os anexos da dissertação. / In current electricity distribution systems, new methodologies that consider the real-time behavior of the equipment can be applied, involving special loads such as electric vehicles (EV) and distributed energy resources (RD) systems. In this work a literature review is presented, which shows the analysis of the development of the distribution systems planning, related to expansion and the operation, considering the conventional methodologies and those that consider the RD\'s, concluding that nowadays it is not possible to analyze a system without RD,s and EV\'s to operate a system with this type of generation and loads on the network. The study of the optimization tools allows to determine the techniques to be used. This work covers two, Depth-first search and Genetic Algorithms, in order to obtain an optimal location of voltage regulators, capacitor banks, photovoltaic and storage systems, that allow to maintain the voltage within the appropriate range established by the National Electric Energy Agency (ANEEL). Then, it the methodology developed is presented with the software used, namely, OpenDSS to solve power flows with distributed resources and MATLAB to program the optimization algorithms. The results in a real size network (ckt5) and in a 13-bus IEEE test network show the importance of considering information of the load curve and the generation profiles of distributed resources within the methodologies, aiming to achieve solutions according to the reality of the distribution systems. After that, future activities are presented, which will allow to cover aspects within the objective function, such as the voltage ratings established by the ANEEL, and insertion of other generation sources, such as wind systems as well as considering the periods of the planning stages within the methodology developed. Evertrally the conclusions, bibliographical references and the attachments of the dissertation are present.
208

Despacho Óptimo de una Central Solar con Almacenamiento de Calor en Sales

Maldonado Gálvez, Paula Daniela January 2011 (has links)
Ingeniera Civil Electricista / La presente memoria tiene por objetivo principal optimizar el despacho de una central solar térmica, que tiene como sistema de almacenamiento tanques de sales fundidas, y que además considera el funcionamiento de una caldera auxiliar para recalentar el fluido circulante en el campo solar. Para cumplir con el objetivo se evaluaron los principales factores influyentes, se realizó un análisis del comportamiento de los costos marginales de las dos subestaciones cercanas a la posible ubicación de la planta, estimando el funcionamiento mensual de la planta para diferentes formas de operación. En este contexto, se implementó un mapa de comportamiento de la central, para estudiar el funcionamiento en un rango variado de escenarios, para así obtener una estadística de las horas en las que el almacenamiento estaba activo, y cuando era la caldera auxiliar la que tenía el peso de la generación. Asimismo fue posible discernir las combinaciones de salida de turbina y porcentaje de combustible fósil que lograban una mejor eficiencia del bloque de potencia. El mapa de comportamiento también identificó los escenarios en los que el fluido térmico alcanza su mayor temperatura y se tenía una cantidad más alta de pérdidas térmicas, además de identificar en qué meses se generaba el mayor gasto en combustible fósil. Una vez terminado el mapa de comportamiento, se diseñaron dos conjuntos de estrategias, una plana a lo largo del día, con una salida de turbina al 100% y otra que permite una fluctuación de generación entre un 80% y un 110%. Cada conjunto está definido por diferentes escenarios, en algunos de los cuales se daba preferencia al almacenamiento y en otros a la caldera auxiliar. Los resultados de las estrategias diseñadas se valorizaron, obteniendo los ingresos por generación y los costos por concepto de combustible fósil para la caldera auxiliar. Además se determinaron las alternativas que presentaban una mejor eficiencia a lo largo del año. Se determinó que el escenario que contemplaba una generación diferenciada a lo largo del día, pese a tener durante gran parte del año un margen de ingreso similar a la producción plana, era una mejor opción dado que el gasto en combustible era menor y, por lo tanto, implica una menor contaminación por emisiones de dióxido de carbono. Finalmente se presenta un resumen del comportamiento de la central, con los datos de generación bruta y neta anual, el consumo de agua, las horas de generación y la eficiencia promedio de la planta.
209

Análisis preliminar de la conversión de una central hidroeléctrica convencional en una de bombeo. Caso Central Chapiquiña, Región de Arica y Parinacota, Chile

Ulloa Alvarado, Andrés Camilo January 2016 (has links)
Ingeniero Civil / Uno de los mayores desafíos del país durante los próximos 20 años será la necesidad de contar con recursos energéticos suficientes, competitivos y amigables con el medio ambiente. Es por ello que en el último tiempo se han centrado muchos esfuerzos en lograr flexibilizar el sistema, y una de las alternativas que aparece con fuerza es el almacenamiento de energía. La estrategia nacional de energía (Minenergía, 2013) establece seis pilares fundamentales, entre los que se encuentran el crecimiento con eficiencia energética y el fomento a las energías renovables, de manera de lograr mayor seguridad en el abastecimiento, un menor costo de energía y finalmente la generación de energía limpia. En este trabajo se analiza, a nivel de prefactibilidad, la conversión de la Central Hidroeléctrica Chapiquiña en una central de acumulación por bombeo. Para ello se estudiará el sistema energético de Arica, de manera de establecer la operación óptima del sistema para abastecer la demanda energética al menor costo posible. La metodología propuesta consiste en generar diversas configuraciones físicas factibles para la conversión de la Central Chapiquiña en una central de acumulación por bombeo. Para ello se identificaron las principales restricciones para su ampliación, siendo estas la capacidad de aprovechamiento de las instalaciones existentes y las restricciones en el uso de los afluentes a la central, que pertenecen a derechos de agua de los regantes del Valle de Azapa. Luego mediante un modelo de optimización, se busca obtener la operación óptima de cada una de estas configuraciones. Finalmente, se analiza cuál de estas configuraciones genera mayor beneficio para el sistema eléctrico, en términos de minimización de costos de generación. Esta metodología se aplica para diferentes escenarios de penetración de energía solar en el sistema eléctrico. Además, se compara la operación óptima desde el punto de vista del sistema (minimización de costos de generación), con la operación óptima desde el punto de vista del propietario (maximización de ingresos por venta de energía), de manera de establecer si existen diferencias que perjudiquen al sistema o al propietario. Los resultados indican que, para niveles de energía solar instalada menores a 50 (MW), la configuración que logra minimizar los costos de generación del sistema es la configuración P8, logrando reducir los costos en un 6,8% para una potencia solar instalada de 2 (MW) y un 8,7% para una potencia solar instalada de 50 (MW). En caso de que la energía solar instalada sea mayor a 50 (MW), la configuración que logra minimizar los costos de generación del sistema es la configuración Francis, la cual logra reducir los costos de generación en un 18,8%.
210

Efeito da ingestão isolada de cafeí­na e bicarbonato de sódio sobre a contribuição energética, desempenho e reativação parassimpática em simulação de luta de taekwondo / Effect of the isolated intake of caffeine and sodium bicarbonate on the energy contribution, performance and parasympathetic reactivation after simulation of taekwondo fight

João Paulo Lopes da Silva 11 December 2017 (has links)
O objetivo do trabalho foi investigar o efeito da suplementação isolada de cafeína e bicarbonato de sódio sobre a contribuição dos sistemas energéticos, desempenho e reativação parassimpática após simulação de luta de taekwondo. Para tanto, a presente tese foi dividida em estudo 1, com a suplementação de cafeína e estudo 2, com a suplementação de bicarbonato de sódio. Portanto, no estudo 1, o objetivo foi investigar o efeito da suplementação de cafeína sobre a contribuição dos sistemas energéticos, desempenho e reativação parassimpática em simulação de luta de taekwondo. 10 atletas de taekwondo foram submetidos a duas sessões experimentais separadas por no mínimo de 48 horas entre elas. Nas duas visitas os atletas consumiram uma cápsula contendo cafeína (5 mg.kg-1 de massa corporal) ou placebo (celulose) uma hora antes da simulação da luta de taekwondo, composta por 3 rounds de 2 minutos com 1 minuto de intervalo entre os rounds. A ordem das sessões experimentais foi randomizada, duplo-cego e cruzada. Todas as simulações de luta foram filmadas para quantificar as ações técnico-táticas durante os rounds. Foram mensuradas a concentração de lactato, a percepção subjetiva de esforço (PSE) antes e após cada round,e a frequência cardíaca (FC) e a contribuição dos sistemas energéticos foi estimada durante a simulação de luta. Além disso, foram mensurados alguns índices da reativação parassimpática após o terceiro round. A concentração de lactato, a PSE, a FC e a contribuição dos sistemas energéticos foram comparados usando análise de variância de dois fatores (condição e tempo). Adicionalmente, os índices da reativação parassimpática foram comparados utilizando o teste t de Student entre as condições cafeína e placebo. Os principais resultados indicam que: a suplementação de cafeína aumentou a contribuição do sistema glicolítico em relação ao placebo. Porém, a cafeína não melhorou o desempenho ou alterou a PSE, a FC ou a contribuição dos sistemas oxidativo e ATP-CP quando comparados ao placebo. Adicionalmente, nenhum índice da reativação parassimpática foi afetado pela suplementação de cafeína. No estudo 2, o objetivo do estudo foi investigar o efeito da suplementação de bicarbonato de sódio sobre a contribuição dos sistemas energéticos durante a simulação de luta de taekwondo. Para tanto, foram avaliados 9 atletas de taekwondo, os quais foram submetidos a duas condições experimentais, separadas por um mínimo de 48 horas entre elas. Nas duas visitas os atletas ingeriram uma cápsula contendo 0,03 g.kg-1 da massa corporal de NaHCO3- ou placebo (carbonato de cálcio), 90 minutos antes da simulação de luta de taekwondo, composta por 3 rounds de 2 minutos com 1 minutos de intervalo entre os rounds. A ordem das sessões experimentais foi randomizada, duplo-cego e cruzada. Todas as simulações de luta foram filmadas para quantificar as ações técnico-táticas durante os rounds. Foram mensuradas a concentração de lactato, a percepção subjetiva de esforço antes e após cada round, a frequência cardíaca e a contribuição dos sistemas energéticos foram estimadas durante a simulação de luta. Além disso, foram mensurados alguns índices da reativação parassimpática após o terceiro round. A concentração de lactato, a PSE, a FC e a contribuição dos sistemas energéticos foram comparadas usando análise de variância de dois fatores (condição e tempo). Além disso, os índices da reativação parassimpática foram comparados utilizando o teste t de Student entre as condições NaHCO3 e placebo. Os principais resultados demonstraram que a suplementação de NaHCO3 aumentou a contribuição do sistema glicolítico e o tempo total de ataque em relação ao placebo. Porém, o NaHCO3 não alterou a FC, a PSE ou a contribuição dos sistemas oxidativo e ATP-CP durante a simulação de luta quando comparados ao placebo. Além disso, nenhum índice da reativação parassimpática foi afetado pela suplementação de NaHCO3 ou placebo / The aim of this study was to investigate the isolated effect of caffeine and sodium bicarbonate ingestion on performance, estimated energy system contribution and on post-exercise parasympathetic reactivation during a simulated taekwondo combat. Therefore, this thesis was divided in two studies: study 1 investigated the effect of caffeine, while study 2 investigated the effect of sodium bicarbonate. Thus, in study 1, the aim was to investigate the effect of caffeine supplementation on performance, estimated energy system contribution and on post-exercise parasympathetic reactivation during a taekwondo combat. Ten taekwondo athletes completed two experimental sessions separated by at least 48 hours. Athletes consumed a capsule containing either 5 mg?kg-1 body mass of caffeine or placebo (cellulose) one hour before the combat simulation (3 rounds of 2 min separated by 1-min passive recovery), in a double blinded, randomized, repeated-measures crossover design. All simulated combat was video recorded to quantify the time spend fighting in each round. Lactate concentration and rate of perceived exertion were measured before and after each round, while heart rate and the estimated contribution of oxidative, ATP-PCr and glycolytic systems were calculated during the combat simulation. Furthermore, parasympathetic reactivation after the combat simulation was evaluated. Lactate concentration, rate of perceived of exertion, heart rate, estimated system contributions and indices of time-motion were compared by two-way ANOVA (condition x time). All indices of parasympathetic reactivation were compared using a Student\'s t-test in both caffeine and placebo conditions. The main results showed that caffeine ingestion increased the estimated glycolytic system when compared to placebo condition. However, caffeine ingestion did not alter the rate of perceived exertion, heart rate, estimated oxidative and ATP-PCr contribution or improve the performance in relation to placebo condition. Furthermore, caffeine ingestion did not influence post-exercise parasympathetic reactivation following a taekwondo simulation when compared to placebo condition. In study 2, the main aim of the study was to investigate the effect of sodium bicarbonate ingestion on performance, estimated energy system contribution and on post-exercise parasympathetic reactivation during simulated taekwondo combat. Nine taekwondo athletes completed two experimental sessions separated by at least 48 hours. Athletes consumed 300 mg?kg-1 body mass of sodium bicarbonate or calcium bicarbonate (placebo) 90 minutes before the combat simulation (3 rounds of 2 min separated by 1-min passive recovery), in a double blinded, randomized, repeated-measures crossover design. All simulated combat was video recorded to quantify the time spent fighting in each round. Lactate concentration and rate of perceived exertion were measured before and after each round, while heart rate, estimated contribution of oxidative, ATP-PCr and glycolytic systems were calculated during the combat simulation. Furthermore, parasympathetic reactivation after the combat simulation was calculated. Lactate concentration, rate of perceived exertion, heart rate, estimated system contributions and indices of time-motion were compared by two-way ANOVA (condition x time). All indices of parasympathetic reactivation were compared using a Student\'s t-test. The main results showed that sodium bicarbonate ingestion increased the lactate concentration, estimated glycolytic contribution and total attack time when compared with placebo condition. However, sodium bicarbonate ingestion did not influence heart rate, rate of perceived exertion, estimated oxidative and ATP-PCr contribution during combat simulation compared to placebo. Furthermore, no indices of parasympathetic reactivation were different between sodium bicarbonate and placebo conditions

Page generated in 0.1007 seconds