• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 102
  • 10
  • 10
  • 10
  • 10
  • 8
  • 2
  • 2
  • 1
  • Tagged with
  • 104
  • 104
  • 57
  • 29
  • 28
  • 22
  • 18
  • 17
  • 17
  • 14
  • 13
  • 10
  • 10
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Estabilidade de cor de cimentos resinosos ativados de forma foto e dual em função de diferentes cores / Redox potencial of ascorbic acid after sodium hypochlorite deproteinization to root dentine with different adhesive systems

Leonardo Fernandes da Cunha 01 July 2013 (has links)
O objetivo deste estudo foi o de avaliar a estabilidade de cor de diferentes cores de cimento (transparente, claro, e escuro) polimerizados de forma foto (Choice 2 Bisco, Rely X Veneer - 3M ESPE) ou dual (Variolink II Ivoclar-Vivadent, All Cem FGM). Um espectrofotômetro (Easyshade - VITA) foi usado para medir a cor das amostras (n=6) imediatamente após a confecção do espécime, 7 dias, 30 dias e 90 dias após. Os valores médios de diferença de cor (ΔE) foram maiores para as cores transparente (ΔE = 4,41), seguido pelas cores claras (ΔE = 3,12) e escuras (ΔE = 3,25). Os valores médios de ΔE foram menores para os cimentos fotoativados (Choice 2 ΔE = 2,79; Rely X VeneerΔE = 3,49) em comparação com os cimentos duais (Variolink II ΔE = 3,60; All Cem ΔE = 4,48). Um aumento dos valores ΔE foram observados com o aumento dos períodos de tempo avaliados (7 dias ΔE = 2,79; 30 dias ΔE = 3,73; 90 dias ΔE = 4,25). / The aim of this study was to evaluate the color stability of different cement color (transparent, clear, and dark) of light-polymerized resin cement (Choice 2 - Bisco, Rely X Veneer - 3M ESPE) or dual-cured cement (Variolink II Ivoclar- Vivadent , All Cem - FGM). Spectrophotometer (Easyshade - VITA) was used to measure the color of samples (n = 6) immediately after preparation, 7 days, 30 days and 90 days. The mean color difference (ΔE) was higher for transparent colors (ΔE = 4,41), followed by light (ΔE = 3,12) and dark colors (ΔE = 3,25). The mean values of ΔE were lower for the light-polymerized resin cement (Choice 2 ΔE = 2,79; Rely X Veneer ΔE = 3,49) compared to the dual-cured cement (Variolink II ΔE = 3,60; All Cem ΔE = 4,48). An increase in ΔE values was observed with increasing periods of time (7 days ΔE = 2,79; 30 days ΔE = 3,73; 90 days ΔE = 4,25).
82

Estudos "in vitro" e "in situ" do efeito de agentes clareadores contendo peroxido de carbamida sobre a microdureza de tecidos dentais higidos e desmineralizados

Basting, Roberta Tarkany 17 October 2001 (has links)
Orientador : Monica Campos Serra / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-31T20:07:36Z (GMT). No. of bitstreams: 1 Basting_RobertaTarkany_D.pdf: 4678774 bytes, checksum: 8ce9e67d4c1c0732c463c5d384f0fbe2 (MD5) Previous issue date: 2001 / Resumo: A utilização do peróxido de carbamida nas técnicas de clareamento dental caseiro vem se tornando cada vez mais freqüente nos consultórios odontológicos por ser um método simples e eficaz para minimizar ou remover manchas intrínsecas ou extrínsecas dos dentes. Devido ao íntimo contato do agente clareador com os tecidos dentais por um prolongado período de tempo e às características inerentes aos componentes produto, alterações da microdureza superficial do esmalte e dentina podem ser esperados. Desse modo, os objetivos deste trabalho, composto por cinco artigos científicos, foram: a) avaliar in vitro a microdureza do esmalte dental humano hígido submetido ao tratamento com dois agentes clareadores de peróxido de carbamida a 10% em diferentes tempos; b) avaliar in vitro a microdureza do esmalte dental humano hígido submetido ao tratamento com dois agentes clareadores de peróxido de carbamida a 10% associado à utilização de dois dentiftícios dessensibilizantes em diferentes tempos e em um período pós-clareamento; c) avaliar in vitro a microdureza da dentina humana hígida submetida ao tratamento com dois agentes clareadores de peróxido de carbamida a 10% em diferentes tempos e em um período pós-clareamento; d) avaliar in vitro a microdureza do esmalte dental humano Lhígido submetido ao tratamento com diferentes concentrações de agentes clareadores de peróxido de carbamida em diferentes tempos e em um período pós-clareamento; e) avaliar in situ a microdureza do esmalte e da dentina hígidos e desmineralizados submetidos ao tratamento com um agente clareador de peróxido de carbamida a 10%, pelo período de três semanas. De acordo com a metodologia utilizada, concluiu-se que diferentes agentes clareadores com a mesma concentração apresentam diferentes efeitos sobre a microdureza superficial do esmalte dental humano hígido. A utilização de dentifiícios dessensibilizantes pode manter ou aumentar a microdureza do esmalte dental humano quando submetido ao tratamento com agentes de peróxido de carbamida a 10%. O peróxido de carbamida a 10% pode diminuir a microdureza superficial da dentina humana hígida em função do tempo; contudo, os valores de microdureza no período pós-clareamento são semelhantes aos valores iniciais devido ao efeito remineralizante da saliva artificial pelo tempo de 14 dias. Diferentes concentrações de peróxido de carbamida podem diminuir a microdureza do esmalte dental humano hígido em função do tempo, embora a saliva artificial apresente um efeito no aumento da microdureza no período pós-clareamento. No estudo in situ, os resultados sugerem que há alterações da microdureza do esmalte dental humano hígido e desmineralizado após o tratamento com o peróxido de carbamida a 10% pelo período de três semanas, embora tais alterações não ocorram para a dentina humana hígida / Abstract: Nightguard vital bleaching with carbamide peroxide agent has become the most ffequent used treatment modality for improving esthetic appearance of teeth, because of its effectiveness and easy application for removing intrinsic and extrinsic stains ffom the teeth. As the bleaching of vital teeth involves the direct contact of the whitening agent on the outer enamel surface for an extensive period of time and due to the characteristics of the components of the bleaching product, changes in enamel and dentin superficial microhardness can occur. This study, composed by tive scientitic artic1es, had the following objectives: a) to in vitro evaluate the microhardi1ess of sound human enamel treated with two 10% carbamide peroxide bleaching materials at different time intervals; b) to in vitro evaluate the microhardness of sound human enamel treated with a 10% carbamide peroxide agent associated with two desensitizing dentiffices at different bleaching times; c) to in vitro evaluate the microhardness of sound human dentin treated with two 10% carbamide peroxide agents at different bleaching times; d) to in vitro evaluate the microhardness of sound human enamel exposed to different concentrations of carbamide peroxide agents at different bleaching times; e) to in situ evaluate the microhardness of sound and demineralized enamel and dentin submitted to treatment with a 10% carbamide peroxide for three weeks. According to the methodology employed in these studies, it was conc1uded that different carbamide peroxide bleaching materiaIs with the same concentration have different effects on the sound human enamel superficial microhardness. The use of desensitizing dentifrices associated with the treatment of a 10% carbamide peroxide bleaching agent could maintain or enhance the human enamel microhardness. Ten percent carbamide peroxide bleaching agents decrease the dentin microhardeness over time, but 14 days after the completion of the treatment, the baseline microhardeness values are recovered due to the remineralizing effect of artificial saliva. Different concentrations of carbamide peroxide bleaching agents decrease the enamel microhardness over time, but the artificial saliva presented a remineralizing effect after 14 days of the completion of the treatment, increasing the enamel microhardness. In the in situ study, the treatment with 10% carbamide peroxide agent can alter the microhardness of sound and demineralized enamel, although it does not seem to affect the microhardness of sound and demineralized dentin / Doutorado / Dentística / Doutor em Clínica Odontológica
83

Estudo clínico comparativo entre diferentes sistemas de clareamento de uso em consultório / Comparative clinical trial between different in-office bleaching systems

Gentil, Flávio Henrique Umeda 22 October 2015 (has links)
Objetivos: Estudos clínicos longitudinais que acompanham os pacientes por longos períodos não são muito comuns na literatura, ainda mais quando associados a grandes amostras (veio do fim do resumo). Por isso, o objetivo do trabalho foi determinar a eficiência, estabilidade de cor e sensibilidade dental, trans e pós operatória, dentro de um período de 365 dias, de quatro protocolos de clareamento em consultório. Material e Métodos: Foi realizado um estudo clínico randomizado, cego (para os pacientes), composto por 120 sujeitos (n=30). A amostra foi formada por pacientes adultos, sem distinção de gênero e etnia, e idade superior a 18 anos que foram selecionados por meio de avaliação clínica na qual foi verificada a cor dos dentes, a condição de higiene oral e a presença de restaurações e/ou próteses nas regiões em que os procedimentos seriam realizados. Todos os sujeitos foram submetidos a uma sessão de clareamento de acordo com as instruções do fabricante e obedecendo a aplicação ou não da luz, para os clareadores baseados no sistema Foto-Fenton (havia faltado citar nos métodos do resumo), e qual o seu tipo: Zoom Advanced Power, peróxido de hidrogênio (PH) 25% - Zoom! + luz UVA (Phillips Oral Healthcare); Zoom Whitespeed, PH 25% - Zoom! + luz Whitespeed (Phillips Oral Healthcare); Zoom sem luz, PH 25% - Zoom! (Phillips Oral Healthcare). Boost, PH 38% - Opalescence Xtra Boost (Ultradent). As alterações de cor foram avaliadas utilizando as escalas Vita Classical e Vita Bleachedguide 3D Master e o Espectrofotômetro Vita-Easyshade. As medições foram feitas em incisivos centrais e caninos uperiores antes, imediatamente e 7, 14, 30, 180 e 365 dias após o tratamento. Os dados foram analisados estatisticamente por meio do software Statistica 8.0 (StatSoft - Tulsa, OK) através da análise de variância (ANOVA) para medidas repetidas na avaliação das médias e as comparações foram realizadas através de contrastes (Tukey). Resultados: Para a escala Vita Classical, Zoom AP e WS foram semelhantes entre si porém diferentes de Opalescence e Zoom sem luz, exceto para a avaliação de 30 dias (caninos) e 365 dias (incisivos) onde o Zoom WS demonstrou dados semelhantes ao Opalescence e Zoom sem luz Já para a escala Vita Bleached, Zoom AP e WS foram semelhantes entre si, porém diferentes de Opalescence e Zoom sem luz, exceto para as avaliações de 30 e 180 dias onde o Zoom WS demonstrou dados semelhantes ao Opalescence e Zoom sem luz (caninos). Para dentes incisivos, os achados foram semelhantes, exceto que houve diferença entre o Zoom AP e WS e as semelhanças entre Zoom WS, Opalescence e Zoom sem luz foram encontradas nas avaliações de 180 e 365 dias. Na avalição com o espectrofotômetro Vita Easyshade Zoom AP e WS foram semelhantes entre si e diferentes do Opalescence que, por sua vez, foi diferente do Zoom sem luz, exceto para as avaliações de 7, 14 e 30 dias (caninos). Para incisivos, Zoom AP e WS foram semelhantes entre si e diferentes de Opalescence e Zoom sem luz, exceto para a avaliação de 14 dias onde o Zoom AP foi diferente do Zoom WS. Por fim, a sensibilidade apresentou um aumento nos seus valores na avaliação imediatamente após o clareamento, com uma redução na avalição de 7 dias, para todos os grupos que ainda apresentaram valores de sensibilidade semelhantes em todos os períodos de avaliação. Conclusão: O acompanhamento até 365 dias demonstrou a eficiência dos protocolos de clareamento analisados uma vez que nenhum deles recidivou para os tons iniciais, demonstrando a durabilidade dos procedimentos. Os dois grupos com os clareadores Foto-Fenton obtiveram maior efeito clareador (substituiu desempenho, tinha ficado vago), exceto nas seguintes avaliações: Vita Classical, 30 dias (caninos) e 365 dias (incisivos) e Vita Bleached, 30 e 180 dias (caninos) e 180 e 365 dias (incisivos). Observou-se uma estabilização da cor após sete dias em todos os grupos. A sensibilidade pós operatória foi mais intensa nos primeiros 7 dias e nenhum paciente relatou sensibilidade a partir da avaliação de 14 dias. / Objectives: Longitudinal clinical studies that follow patients for long periods are not very common in the literature, especially when associated with large samples. The objective of this study was to determinate the efficacy, color stability and sensitivity within a 365 day period of four in-office bleaching protocols. Methods: A randomized clinical trial, blinded (for patients), composed of 120 subjects (n=30) was conducted. The sample consisted of adult patients, without gender and ethnic distinction, with age superior than 18 years old that were selected through clinical evaluation in which was verified the color of teeth, the condition of oral hygiene and the presence of restorations and/or prostheses in the areas where the procedures would be carried out. All subjects were submitted to a session of bleaching according to the manufacturer\'s instructions: Zoom Advanced Power, 25% hydrogen peroxide (HP) - Zoom! + UVA light (Phillips Oral Healthcare); Zoom Whitespeed, 25% HP - Zoom! + Whitespeed light (Phillips Oral Healthcare); Zoom without light, 25% HP - Zoom! (Phillips Oral Healthcare). Boost, 38% HP - Opalescence Xtra Boost (Ultradent). Color changes were evaluated using Vita Classical and Vita Bleachedguide 3D Master shade guides and Vita-Easyshade spectrophotometer. Measurements were made on the superior central incisive and canines before, immediately and 7, 14, 30, 180 and 365 days after the treatment. Statistical analysis of the data were made with the software Statistica 8.0 (StatSoft - Tulsa, OK) through the analysis of variance (ANOVA) for repeated measures in the mean evaluation and comparisons were made by using contrasts (Tukey). Results: For the Vita Classical shade guide, Zoom AP and WS were similar but different from Opalescence and Zoom without light except for the 30 day (canines) and 365 days evaluations (incisives) where the Zoom WS showed similar data to Opalescence and Zoom without light. As for the Vita Bleached shade guide, Zoom AP and WS were similar, but different from Opalescence and Zoom without light, except for the 30 and 180 days evaluation where Zoom WS showed similar data to Opalescence and Zoom without light (canines). For incisives, the findings were similar, except that there were differences between Zoom AP and WS and the similarities between Zoom WS, Opalescence and Zoom without light were found in the 180 and 365 days evaluations. For the evaluation with Vita Easyshade spectrophotometer, Zoom AP and WS were similar and different from Opalescence which was different from Zoom without light, except for the 7, 14 and 30 days evaluation (canines). For incisives, Zoom AP and WS were similar and different from Opalescence and Zoom without light, except for the 14 days evaluation where Zoom AP was different from Zoom WS. Finally, the sensitivity showed an increase in their values for the immediately after bleaching evaluation, with a reduction in the 7 days evaluation for all groups that still had similar sensitivity values in all evaluation periods. Conclusion: The follow-up to 365 days demonstrated the efficiency of the analyzed bleaching protocols since none relapsed to the initial shades, demonstrating the durability of the procedures. The two groups with the Photo-Fenton bleaching systems performed better, except for the following evaluations: Vita Classical, 30 days (canines) and 365 days (incisives) and Vita Bleached, 30 and 180 days (canines) and 180 and 365 days (incisives). There was a color stabilization after seven days in all groups. Postoperative sensitivity was more intense in the first 7 days and no patient reported sensitivity since the 14 days evaluation.
84

Efeito da neutralização do ácido fluorídrico, limpeza sônica dos precipitados e da cimentação sobre a resistência à flexão de uma cerâmica vítrea /

Saavedra, Guilherme de Siqueira Ferreira Anzaloni. January 2008 (has links)
Resumo: O objetivo deste trabalho foi avaliar cinco hipóteses: a) o condicionamento ácido diminui a resistência à flexão de uma cerâmica feldspática; b) a cimentação aumenta os valores de resistência à flexão de uma cerâmica feldspática; c) o processo de neutralização dos precipitados do ácido fluorídrico diminui os valores de resistência à flexão de uma cerâmica feldspática; d) a limpeza sônica (ultra-som) com água deionizada dos precipitados do ácido fluorídrico, formados sobre a superfície cerâmica após o condicionamento ácido, aumenta os valores de resistência à flexão de uma cerâmica feldspática; e) a associação entre o processo de neutralização dos precipitados do ácido fluorídrico e a limpeza sônica melhora a resistência à flexão de uma cerâmica feldspática. Foram confeccionadas 60 barras cerâmicas (20x4x1.2mm) (VM7 VITA Zahnfabrik). Cada barra cerâmica (1face) (exceção G1) foi condicionada (20s) com AF10% (Dentsply), seguida pela lavagem jato ar-água (60s) e secagem. Foram selecionadas aleatoriamente e separadas em 6 grupos(n=10): G1 - Controle (sem tratamento); G2 - condicionamento ácido apenas; G3 - o silano(Porcelain Primer,BISCO) foi aplicado na superfície cerâmica seguido da cimentação resinosa (Rely X ARC/3M); G4 - as barras foram imersas (40s) em solução supersaturada de bicarbonato de sódio, lavadas jato ar-água por (5s) e secas antes da aplicação do silano e cimentação; G5 - limpeza sônica (4min), silano e cimentação; G6 - associação da neutralização e limpeza sônica, seguido da silanização e cimentação. Após armazenagem (água destilada/sete dias a 37ºC), cada conjunto cerâmica/cimento) foi levado ao dispositivo de ensaio, sendo este acoplado em uma máquina de ensaios universal (EMIC) com célula de carga de 10Kgf, velocidade de 1,0mm/min e submetidos ao ensaio mecânico de flexão 3 pontos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this study was to evaluate five hypotheses: a) hydrofluoric acid etching decreases the flexural strength of a feldspathic porcelain; b) cementation increases the flexural strength of a feldspathic porcelain; c) the neutralization process of hydrofluoric acid precipitates decreases the flexural strength of a feldspathic porcelain; d) hydrofluoric acid precipitates cleaning with ultrasonic bath in deionized water, formed on the ceramic surface after acid etching, increases flexural strength values of a feldspathic porcelain; e) the association between the neutralization process of the hydrofluoric acid precipitated and ultrasonic sonic cleaning improves the flexural strength of a feldspathic porcelain. Sixty ceramic bars (20x4x1.2mm) (VM7 VITA Zahnfabrik) were made and each one (1 surface) (except G1) was etched (20s) with HF10% (Dentsply), followed by water spray (60s) and drying. The specimens were randomly divided into 6 groups (n=10): G1 - Control (no treatment); G2 - hydrofluoric acid; G3 - silane(Porcelain Primer,BISCO) was applied on porcelain surface followed adhesive cementation (Rely X ARC/3M); G4 - the bars were immersed on a oversaturated sodium bicarbonate solution (40s), washed by water spray (5s) and drying before silane application and cementation; G5 - ultrasonic cleaning (4min), silane and cementation; G6 - association between neutralization and ultrasonic cleaning, followed by silanization and cementation. After storage (distillated water/ 7 days at 37ºC), each set (ceramic/cement) was carry to test device, which was mounted in universal test machine (EMIC) with a load cell of 10 Kgf, crosshead speed of 1,0mm/min, and submitted to the three-point bending mechanical test (immersed on water at 37 ºC). The flexural strength values and standard deviation (MPa) of the groups were: G1: 73,79±5,83a; G2: 60,65±10,07b; G3: 85,10±12,40a; G4: 80,91± ... (Complete abstract click electronic access below) / Orientador: Estevão Tomomitsu Kimpara / Coorientador: Tarcísio José de Arruda Paes Junior / Banca: Eduardo Piza Pellizzer / Banca: Maximiliano Piero Neisser / Banca: Rander Pereira Avelar / Banca: Rubens Nisie Tango / Doutor
85

Comparison of microesthetic patterns in normal occlusion in relation to class I malocclusion treated with extractions of four premolars / Comparação dos padrões de micro-estética na oclusão normal em relação à classe I tratada com extrações de quatro pré-molares

Maranhão, Olga Benário Vieira 18 February 2019 (has links)
Introduction: The aim of this research was to compare the microesthetics characteristics of the maxillary anterior tooth in individuals with Class I malocclusion treated with four premolars extractions in relation to normal occlusion as well the evaluation of symmetry between right and left sides in both groups. Methods: The sample was divided into two groups, first one with Angle Class I malocclusion treated with four premolars extraction (mean age of 15.18 and composed by 22 female and 9 male patients), and second one with Normal Occlusion (mean age of 16.93 and comprised by 15 female and 16 male individuals) composed by 31 individuals each. Objective grading system index (OGS) was evaluated in the plaster models of both groups and then digitized in 3D 3Shape R700 scanner (3Shape A/S, Copenhagen, Denmark). The width/height proportion of anterosuperior teeth, zenith location, height of connectors and gingival contour were measured with OrthoAnalyzer 3D program. Random and systematic errors were respectively evaluated with Dahlbergs formula and paired t tests. Mann-Whitney U and t tests were applied to variables without and with normal distribution respectively. Results: In most comparison there was no significant differences between groups. It was noticed in a few situations that Class I group presented significantly greater width/height proportion in 12 than Normal Occlusion; significantly smaller gingival zenith of 23, significantly greater connector in 22 to 23 and also significantly greater gingival contour in right side in comparison to Normal Occlusion group. Both sides of Class I and Normal Occlusion groups presented symmetry. Conclusion: Four premolar extractions orthodontic treatment of Class I malocclusion provides similar microesthetic patterns as individuals with normal occlusion. Both groups generally present symmetric microesthetic characteristics. / Introdução: O objetivo desta pesquisa foi comparar as características de microestética nos dentes anterossuperiores em indivíduos com má oclusão de Classe I tratados com quatro extrações de pré-molares em relação à oclusão normal, bem como a avaliação da simetria entre os lados direito e esquerdo em ambos os grupos. Métodos: A amostra foi dividida em dois grupos, o primeiro com pacientes com má oclusão de Classe I de Angle tratados com extração de quatro pré-molares (idade média de 15,18 e composta por 22 pacientes do sexo feminino e 9 do sexo masculino) e um com Oclusão Normal (média de 16,93 e composto por 15 indivíduos do sexo feminino e 16 do sexo masculino) compostos por 31 indivíduos cada. O Objective Grading System Index (OGS) foi avaliado nos modelos de gesso dos dois grupos, os quais foram digitalizados em seguida no scanner 3D 3Shape R700 (3Shape A / S, Copenhagen, Dinamarca). A proporção largura / altura dos dentes anterossuperiores, a localização do zênite, a altura dos conectores e o contorno gengival foram medidos com o programa OrthoAnalyzer 3D. Erros casuais e sistemáticos foram avaliados respectivamente com a fórmula de Dahlberg e testes t pareados. Os testes U e t de Mann-Whitney foram aplicados às variáveis sem e com distribuição normal, respectivamente. Resultados: Na maioria das comparações não houve diferenças significativas entre os grupos. Percebeu-se que o grupo com Classe I apresentou proporção de largura / altura significativamente maior no incisivo lateral direito em relação à oclusão normal; zênite gengival significativamente menor no canino esquerdo, significativamente maior no conector entre o incisivo lateral esquerdo e canino esquerdo, e significativamente maior no contorno gengival do lado direito em comparação ao grupo de oclusão normal. Ambos os lados dos grupos Classe I e Oclusão Normal apresentaram simetria. Conclusão: O tratamento ortodôntico com extrações de quatro pré-molares da má oclusão de Classe I fornece padrões microestésicos semelhantes aos indivíduos com oclusão normal. Ambos os grupos apresentaram simetria na maioria das características de microestética.
86

Avaliação espectrofotométrica de diferentes sistemas cerâmicos /

Villarroel Cortés, Milko Javier. January 2010 (has links)
Orientador: Osmir Batista de Oliveira Junior / Banca: José Roberto Cury Saad / Banca: Edson Alves Campos / Banca: Leonardo Busso / Banca: Roberto Elias Campos / Resumo: O objetivo deste trabalho foi avaliar espectrofotometricamente a transmitancia direta e refletância de diferentes sistemas cerâmicos. Foram selecionados 12 sistemas cerâmicos: Grupo I Cercon B (Dentsply); Grupo II Cercon A (Dentsply); Grupo III In-Ceram Alumina (Vita); Grupo IV In-Ceram Spinell (Vita); Grupo V Procera Zirconia 2 (Nobel Biocare); Grupo VI Procera Zirconia 3 (Nobel Biocare); Grupo VII Procera Zirconia 4 (Nobel Biocare); Grupo VIII Procera Zirconia 5 (Nobel Biocare); Grupo IX IPS e.max Press MO (Ivoclar- Vivadent); Grupo X IPS e.max Press HO (Ivoclar-Vivadent); Grupo XI Zirconforce (Cubo) e Grupo XII IPS d.sing (Ivoclar-Vivadent). Utilizou-se um espectrofotômetro para corpos sólidos calibrado para registrar a transmitância da luz com comprimento de onda de 400 a 700nm. Foram confeccionados 5 corpos de prova de infra-estrutura cerâmica (15mm de diâmetro e 0,5mm de espessura) para cada grupo de acordo com a especificações do fabricante. Os valores de transmitância direta foram analisados mediante o teste ANOVA (p<0,05). Pode-se observar que existem diferenças significativas entre os grupos G3, G9 e G12 que apresentaram um comportamento significantemente distinto entre si e entre todos os outros grupos. Não houve diferenças entre os grupos G4, G5, G6, G7, G8, G10 e G11 e entre G1 e G2 para os valores máximos de transmitância. Posteriormente, em uma segunda etapa, os corpos de prova de infra-estrutura foram completados com cerâmicas de cobertura indicada pelo fabricante de cada grupo, obtendo as seguintes dimensões: 15mm de diâmetro e 2mm de espessura. As amostras foram submetidas ao teste de transmitância direta e os resultados foram submetidos ao teste ANOVA (p<0,05). A análise estatística demonstrou diferenças estatísticas entre os grupos em estudo em que G9 e G12 tiveram um comportamento significativamente distinto entre si e com todos os outros grupos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate spectrophotometrically the direct transmittance and reflectance of different ceramic systems. Twelve ceramic systems were selected: Cercon B - Dentsply (Group I), Cercon A - Dentsply (Group II), In-Ceram Alumina - Vita (Group III), In-Ceram Spinell - Vita (Group IV), Zirconia 2 Procera - Nobel Biocare (Group V), Procera Zirconia 3 - Nobel Biocare (Group VI), Zirconia 4 Procera - Nobel Biocare (Group VII), Procera Zirconia 5 - Nobel Biocare (Group VIII), IPS e.max Press MO - Ivoclar-Vivadent (Group IX) and IPS e.max Press HO - Ivoclar-Vivadent (Group X ), Zirconforce - Cubo (Group XI) and IPS d.sing - Ivoclar-Vivadent (Group XII). Spectrophotometer for solids was used calibrated to register in the range of 400 to 700nm. Five ceramic copyings for testing were made (15mm in diameter and 0.5 mm in thickness) for each group according to manufacturer directions. Direct transmittance values were analyzed by ANOVA test (p <0.05). It was observed significant differences between groups G3, G9 and G12 were significantly different behavior between them and all other groups. There were no differences between groups G4, G5, G6, G7, G8, G10, G11 and between G1 and G2 for maximum values of transmittance. In a second stage test bodies were filled with covering ceramic getting the following dimensions: 15mm diameter and 2mm thick. The test bodies were subjected to direct transmittance test and the results were submitted to ANOVA test (p <0.05). Statistical analysis revealed that there were statistical differences between the study groups. G9 and G12 behavior were significantly different between them and all other groups. Same behavior was attributed to groups G5, G6, G7, G8, G10, G11 and between G1 and G2 and between G3 and G4. Finally, complete test bodies were subjected to the reflectance test using the reflectance spectrophotometer CM 2600d (Konica Minolta)... (Complete abstract click electronic access below) / Doutor
87

Hipomineralização molar incisivo : qualidade de vida relacionada à saúde bucal e percepção estética em escolares de 8 a 12 anos /

Fragelli, Camila Maria Bullio January 2016 (has links)
Orientador: Taís de Souza Barbora / Banca: Juliana Feltrin de Souza / Banca: Fabio Scanavino / Banca: Weber Adad Ricci / Banca: Fabiano Jeremia / Resumo: A hipomineralização molar-incisivo (HMI) é um distúrbio de desenvolvimento que acomete primeiros molares e incisivos permanentes. O dente afetado pela HMI pode ser muito sensível tanto a estímulos frios quanto quentes e é frequente a queixa em relação à estética. O objetivo do presente estudo foi identificar o defeito de esmalte conhecido como HMI, em 467 escolares de 8 a 12 anos da rede pública e privada de Araraquara/SP e estabelecer a relação entre a referida condição e as percepções da criança e dos pais ou responsáveis sobre a estética dentária da criança e a qualidade de vida relacionada à saúde bucal da criança. Os escolares foram examinados quanto à presença de cárie dentária e severidade de HMI. Para verificar a percepção da criança sobre sua estética dentária e qualidade de vida relacionada à saúde bucal, foram utilizadas as versões brasileiras do Child's Questionnaire About Teeth Appearance e do Child Perceptions Questionnaries, respectivamente e seus pais preencheram as versões brasileiras do Parent's Questionnaire About Teeth Appearance e do Parental-Caregiver Perceptions Questionnarie. Os dados coletados foram analisados utilizando-se os softwares SPSS 16.0 e BioEstat 5.0 por meio de estatística descritiva, teste de normalidade de Kolmogorov-Smirnov, teste Mann-Whitney e Kruskal-Wallis, teste de correlação de Spearman e análises de regressão linear, considerando a presença e severidade de HMI como fatores dependentes. Nos pré-adolescentes entre 11 e 12 anos afet... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The Molar-Incisor Hypomineralization (MIH) is a developmental disorder that affects the first molars and permanent incisors. The tooth affected by MIH can be very sensitive with cold as hot stimulus and is a frequent associate with aesthetics problems. The aim of this study was to identify the enamel defect known as MIH in 467 schoolchildren aged 8 to 12 years of public and private school form Araraquara-SP and establish the relationship between the condition and the child's and parents or guardians perceptions on children's dental aesthetics and Oral Health Related Quality of Life (OHRQoL). The children were examine for the presence and severity of dental caries and MIH. To check the child's perception about their dental aesthetics and OHRQoL, the brazilian versions of the Child's Questionnaire About Teeth Appearance and Child Perceptions Questionnaries were used, respectively, and their parents completed the brazilian versions of Parent's Questionnaire About Teeth Appearance and Parental-Caregiver Perceptions Questionnaire. The collected data were analyze using the SPSS 16.0 and Bioestat 5.0, using descriptive statistics, normality Kolmogorov-Smirnov, Mann-Whitney and Kruskal-Wallis, Spearman Correlation test and Linear Regression analysis considering the presence and severity of MIH as dependent factors. In pre-adolescents between 11 and 12 years affected by MIH and current or previous experience with tooth decay was observed impacts on OHRQoL in the social welfare field w... (Complete abstract click electronic access below) / Doutor
88

INFLUÊNCIA DO SISTEMA ADESIVO NA COR DE RESINAS COMPOSTAS / INFLUENCE OF THE ADHESIVE SYSTEM IN THE COLOR OF RESIN COMPOSITES

Ritter, Débora Diniz 02 July 2015 (has links)
The aim of this study was to evaluate the influence of different adhesive systems in the color of resin composites with different translucency. Sixty specimens of resin composite, in the shades A2 (n=30) e OA2 (n=30) were made with aid of a metallic mould with 8 mm of intern diameter and 1.25 mm of thickness, and randomly divided according to the adhesive system: two-step etch-and-rinse (Adper Single Bond 2; 3M ESPE), two-step self-etch (Clearfil SE Bond; KURARAY) and universal (Single Bond Universal; 3M ESPE). The materials were applied on the surface of the disk-shaped specimens, simulating direct restorations. The color evaluations were measured with spectrophotometer immediately after the polishing the specimens and after the application of the adhesive systems. The data of CIE L*a*b* system were used for the calculus of ΔE, ΔL, Δa e Δb. Additionally, 5 specimens of each adhesive system were made with the same dimensions of the disks of resin composite for measurement of the L*, a* e b* parameters. The data obtained were subjected to Analysis of Variance and Tukey test (5%). The application of the adhesive system Single Bond Universal on resin composite A2 resulted in highest color change p= 0.000; ΔE = 3.1 ± 0.7). No statistical significant difference was observed among adhesive systems when applied on resin composite shade OA2 (p>0.05). The universal adhesive showed higher trend to green and yellow. In conclusion, the effect of the adhesive system is material-dependent. The adhesive Single Bond Universal results in higher color change when a resin composite with higher translucency is used. / O objetivo deste estudo foi avaliar a influência de diferentes sistemas adesivos na cor de resinas compostas com diferentes translucidez. Sessenta corpos de prova de resina composta Z250 XT (3M ESPE), nas cores A2 (n=30) e OA2 (n=30) foram confeccionados com auxílio de uma matriz metálica com 8 mm de diâmetro interno e 1,25 mm de espessura e divididos aleatoriamente de acordo com o sistema adesivo: convencional de dois passos (Adper Single Bond 2; 3M ESPE), autocondicionante de dois passos (Clearfil SE Bond; KURARAY) e universal (Single Bond Universal; 3M ESPE). Os materiais foram aplicados sobre a superfície dos corpos de prova, simulando restaurações diretas. As avaliações de cor foram mensuradas com espectrofotômetro imediatamente após o polimento dos corpos de prova e posteriormente à aplicação dos sistemas adesivos. Os dados do sistema CIE L*a*b* foram utilizados para o cálculo do ΔE, ΔL, Δa e Δb. Adicionalmente, 5 corpos de prova de cada sistema adesivo foram confeccionados com as mesmas dimensões dos corpos de prova de resina composta para mensuração dos parâmetros L*, a* e b*. Os dados obtidos foram submetidos à Análise de Variância e Teste de Tukey (5%). A aplicação do sistema adesivo Single Bond Universal sobre a resina composta A2 resultou em maior alteração de cor (p = 0,000; ΔE = 3,1 ± 0,7). Nenhuma diferença estatisticamente significante foi observada entre os sistemas adesivos quando aplicados sobre a resina composta cor OA2 (p>0,05). O adesivo universal apresentou maior tendência para o verde e para o amarelo. Em conclusão, o efeito do sistema adesivo na cor das resinas compostas é material dependente. O adesivo Single Bond Universal resulta em maior alteração de cor quando uma resina com maior translucidez é utilizada.
89

Avaliação das alterações dos tecidos ao redor de implantes inseridos em diferentes níveis em relação à crista óssea: estudo clínico, radiográfico, e histométrico em cães

Pontes, Ana Emilia Farias [UNESP] 01 March 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:29Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-03-01Bitstream added on 2014-06-13T20:45:03Z : No. of bitstreams: 1 pontes_aef_dr_arafo.pdf: 2180778 bytes, checksum: 4f081c1f4701944b8a6da04a94fa99b3 (MD5) / O objetivo do presente estudo foi avaliar alterações ao redor de implantes inseridos em diferentes níveis em relação à crista óssea, e sob diferentes protocolos de restauração. Trinta e seis implantes foram inseridos nas mandíbulas edêntulas de 6 cães. Três implantes foram instalados por hemi-mandíbula, cada qual representativo de um grupo experimental. Estes foram determinados de acordo com a distância entre a junção implante-conector protético (JIC) e a crista óssea: Ao Nível (ao nível da crista óssea), Menos 1 (1mm apical à crista óssea), ou Menos 2 (2mm apical à crista óssea). Cada hemi-mandíbula foi submetida a um protocolo de restauração: convencional (prótese instalada 120 dias após a implantação) ou imediata (prótese instalada 24 horas após a implantação). Parâmetros clínicos, radiográficos, e histométricos foram avaliados após 90 dias de restauração, e os dados foram analisados estatisticamente (alfa=5%). A posição da margem do tecido mole (PTM) não foi influenciada pelo posicionamento apical da JIC; entretanto, sítios submetidos à restauração imediata tiveram a PTM significantemente mais coronal que os submetidos à restauração convencional (p=0,02, análise clínica). A reabsorção do rebordo não foi estatisticamente diferente entre os grupos (p>0,05, análise radiográfica). Menores quantidades de Perda Óssea Lateral (POL) foram observadas nos sítios restaurados imediatamente em comparação com os restaurados convencionamente (p=0,006, análise histométrica). Os presentes achados sugerem que o posicionamento apical da JIC não põe em risco a altura de tecidos periimplantares moles ou duros. Além disto, a restauração imediata foi benéfica para manter a PTM, e minimizar a POL. / The aim of the present study was to evaluate changes that occur around dental implants inserted in different levels in relation to crestal bone, under different restoration conditions. Thirty-six implants were inserted in the edentulous mandible of six dogs. Three implants were inserted per hemimandible, each one representing an experimental group according to the distance from the implant-abutment junction (IAJ) to the crestal bone: Bone Level (at crestal bone level), Minus 1 (1mm below crestal bone), or Minus 2 group (2mm below crestal bone). Each hemimandible was submitted to a restoration protocol: conventional (prothesis installed 120 days after implant placement) or immediate (prosthesis installed 24 hours after implant placement). Clinical, radiographic, and histometric parameters were evaluated after 90 days of restoration, and data was analyzed statistically (alpha=5%). The position of soft tissue margin (PSTM) was not influenced by the apical positioning of the IAJ; however, sites submitted to immediate restoration had the PSTM displayed significantly more coronally than those submitted to conventional restoration (p=0.02, clinical analysis). Ridge Loss was not statistically different among groups (p>0.05, radiographic analysis). Greater amounts of Lateral Bone Loss (LBL) were observed for conventionally than for immediately restored sites (p=0.006, histometric analysis). These findings suggest that the apical positioning of IAJ did not jeopardize the height of peri-implantar soft and hard tissues. Moreover, immediate restoration was beneficial to maintain the PSTM, and to minimize LBL.
90

Investigação da quebra de pigmentos por luz /

Esteban Florez, Fernando Luis. January 2009 (has links)
Orientador: Osmir Batista de Oliveira Júnior / Banca: Vanderlei Salvador Bagnato / Banca: Carlos EduardoFrancci / Resumo: O clareamento dental é uma técnica que surgiu no inicio do século XIX. Desde então, e em função dos resultados obtidos ao longo do tempo, esta foi sendo alterada de maneira a reduzir os riscos do procedimento e ao mesmo tempo melhorar o resultado estético obtido. Com o aparecimento das fontes de luz para uso odontológico, novas e interessantes possibilidades surgiram e permitiram a utilização de métodos de aceleração que respeitem a fisiologia pulpar, que diminuam o tempo de exposição do paciente aos agentes peróxidos e promovam ainda a obtenção de bons resultados estéticos. Nos dias de hoje, pode-se observar na literatura importantes questionamentos acerca da contribuição efetiva da luz visível no processo e, os efeitos dos agentes peróxidos nas estruturas cristalinas dos dentes, materiais restauradores em geral e tecidos moles. Estas preocupações foram o cerne da motivação para a realização desta pesquisa, sendo assim, este trabalho vem propor uma série de metodologias inovadoras que avaliem através de tecnologias modernas os mecanismos básicos de interação da luz visível com o peróxido de hidrogênio e com os pigmentos orgânicos. Os experimentos aqui demonstrados abordam os fatores críticos relacionados com a eficiência do processo em diferentes substratos por meio de análise de transmitância, de fluorescência e imagens digitais. Com estes estudos pretendemos responder de maneira objetiva algumas das questões que foram observadas serem de fundamental importância no esclarecimento da real eficiência e eficácia da luz no clareamento dental. / Abstract: The dental bleaching is a technique that appeared in the beginning of the XIX century. Since then, and in function of the obtained results a long the time, this has been altered in way to reduce the procedure risks and at the same time improve the aesthetic results. With the rise of light sources to be used in dentistry, new and exciting possibilities appeared and allowed the use of catalytic methods that respect the pulpal physiology, which diminishes the exposure time of the patients to the bleaching agents and provides good aesthetic results. In nowadays, it is possible to observe in the literature important questionings over the real contribution of light in the process and, the effects of the peroxide over the crystalline structure of the teeth, restorative materials and soft tissues. These concerning were the major motivation to the realization of this research, in this way, this work proposes a new series of methods that asses by the use of new technologies the basic mechanisms of visible light interaction with the hydrogen peroxide and with the organic pigments. The experiments here demonstrated study the critical factors related with the process efficiency in different substrates by digital images, transmittance and fluorescence. With these studies we pretend to respond in objective way some questions that were observed to be of fundamental importance in the understanding of the light efficiency and efficacy to the dental bleaching. / Mestre

Page generated in 0.0827 seconds