• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 418
  • 5
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 435
  • 211
  • 109
  • 105
  • 104
  • 88
  • 84
  • 78
  • 71
  • 65
  • 61
  • 52
  • 51
  • 40
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Aplicação da filtração intermitente em leito de areia e de escória da metalurgia do cobre no tratamento de esgotos com ênfase em reuso.

Dultra, Fernando de Almeida 23 March 2007 (has links)
Submitted by infopei ufba (infopei@ufba.br) on 2016-12-07T20:19:03Z No. of bitstreams: 1 dis_fernando_dultra.pdf: 2853632 bytes, checksum: d49c5048b5752d02d081d6d5c1615a1b (MD5) / Approved for entry into archive by Escola Politécnica Biblioteca (biengproc@ufba.br) on 2017-03-16T12:34:41Z (GMT) No. of bitstreams: 1 dis_fernando_dultra.pdf: 2853632 bytes, checksum: d49c5048b5752d02d081d6d5c1615a1b (MD5) / Made available in DSpace on 2017-03-16T12:34:41Z (GMT). No. of bitstreams: 1 dis_fernando_dultra.pdf: 2853632 bytes, checksum: d49c5048b5752d02d081d6d5c1615a1b (MD5) / PROSAB,FINEP,CNPq, FAPESB,PROSAB, FAPESB,LABDEA, Acquabrasillis,Caraíba Metais, Pedreiras Limoeiro, Construtora NM / Este trabalho teve por objetivo avaliar o desempenho de filtros intermitentes, no póstratamento de esgotos sanitários. Primeiramente, o efluente tratado proveio de um sistema composto por um decantador primário, um contactor biológico rotativo - CBR, e um decantador secundário. Na segunda fase o CBR saiu de operação, ficando o tratamento preliminar reduzido a decanto-digestão em três câmaras sépticas, com seis horas de detenção hidráulica. A unidade experimental é composta de doze unidades de filtros intermitentes sendo oito de areia, três de escória de metalurgia de cobre, e uma mista. O sistema trata os esgotos da Escola Politécnica da Universidade Federal da Bahia. Cada filtro tem 0,5 m de altura de leito filtrante, com tamanhos efetivos-TE de 0,4 mm, 0,75 mm, 1,3 mm de areia e 1,2 mm de escória, os coeficientes de uniformidade variaram de 1,13 a 1,83. As taxas de aplicação hidráulica foram de 0,4 m³/m².dia, 1,1 m³/m².dia e 1,4 m³/m².dia, com freqüência de aplicação de doses de 48 vezes por dia. Mesmo com taxas de aplicação mais elevadas que aquelas relatadas em outros trabalhos, obteve-se resultados satisfatórios quanto à remoção de matéria orgânica, ficando a DBO abaixo de 10 mg/L e SST em torno de 5 mg/L. Com respeito a eficiência de redução da matéria orgânica, constata-se que para as elevadas taxas de aplicação, não há diferença significativa entre os diversos TE’s dos leitos filtrantes.Conclui-se que é possível obter efluentes de boa qualidade, operando filtros intermitentes com elevadas taxas de aplicação hidráulica, com leitos de tamanhos efetivos acima de 1,0 mm, sem finos, apresentando carreiras superiores a um ano, o que significa uma diminuta geração de lodo. Os filtros intermitentes, são unidades aeróbias, não geram odores, não geram aerossóis, têm baixo custo operacional, não requerem mão de obra especializada, sua manutenção é simples e econômica, e praticamente não geram lodo. Sua capacidade de abater microrganismos é limitada, principalmente para taxas mais elevadas, porem o efluente é muito clarificado possibilitando a aplicação de diversos processos de desinfecção. Podem ser usados amplamente no tratamento de esgotos de pequenos geradores, de forma descentralizada e possibilitando o reúso. / This work had the objective of evaluating the performance of intermittent sand filters, in the post-treatment of sanitary sewers. First, the treated effluent was from a system composed of a primary decanter, a rotating biological contactor - RBC, and a secondary decanter. In the second phase the RBC left operation, and the preliminary treatment was reduced to decant-digestion in three septic chambers, with six hours of hydraulic detention. The experimental unit is composed of twelve units of intermittent filters which eight of sand, three of slag of copper metallurgy, and one mixing. The system treated the sanitary sewers of the Polytechnic School of the Federal University of Bahia. Each filter had 0,5 m of height of filter stream bed, with effective sizes-ES of 0,4 mm, 0,75 mm, 1,3 mm of sand and 1,2 mm of slag, uniformity coefficients ranged of 1,13 up to 1,83. Rates of hydraulic application had been of 0,4 m ³ /m ².day, 1.1 m ³ /m ².day and 1,4 m ³ /m ².day, with application frequency of doses of 48 times per day. Even with rates of application higher than those reported in other works, it was gotten satisfactory results respecting to the removal of organic matter, with BOD below 10 mg/L and SST around 5 mg/L. Concerning to the organic matter efficiency reduction, one evidences that for the high rates of application, there was no significant difference between diverse ES of the filter stream beds. One concludes that it is possible to get good quality effluent, operating intermittent sand filters with high rates of hydraulic application, with stream beds of effective sizes above 1,0 mm, without fines, presenting careers superior to one year, meaning a low generation of sludge. The intermittent filters are aerobic units, do not generate odors, do not generate aerosols, have low operational cost, do not require skilled worker, its maintenance is easy and economic and they practically do not generate sludge. Its capacity to reduce microorganisms is limited, mainly for higher rates; however the effluent is very clear making possible the application of various disinfection processes. They can be widely used in treatment sewers of small sources, in decentralized way and making reuse possible.
192

Associação entre albuminúria e o ritmo de filtração glomerular com a mortalidade ou recorrência em pacientes com acidente vascular cerebral / Helbert do Nascimento Lima ; orientador, Roberto Pecoits-Filho ; co-orientador, Anderson Ricardo R. Gonçalves

Lima, Helbert do Nascimento January 2009 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2009 / Bibliografia: f. 42-52 / Introducao e objetivos : a doenca renal acelera o processo de aterosclerose e aumenta o risco cardiovascular (CV). A associacao dos marcadores de funcao renal com o acidente vascular cerebral (AVC) nao tem sido bem estabelecida. Com o objetivo de encontra / Objective: Renal dysfunction accelerates the atherosclerotic process and increases cardiovascular (CV) risk. The association of the markers of renal dysfunction with stroke has not been well established. In an attempt to find new predictors of stroke prog
193

Influência da aplicação de esgoto sanitário tratado sobre sistemas de irrigação por gotejamento / Influence of treated sanitary wastewater application on drip irrigation systems

Batista, Rafael Oliveira 26 February 2004 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2017-02-22T17:50:29Z No. of bitstreams: 1 texto completo.pdf: 958077 bytes, checksum: 6b38e92e4f95c0a3db36817664c0e883 (MD5) / Made available in DSpace on 2017-02-22T17:50:29Z (GMT). No. of bitstreams: 1 texto completo.pdf: 958077 bytes, checksum: 6b38e92e4f95c0a3db36817664c0e883 (MD5) Previous issue date: 2004-02-26 / Fundação de Amparo à Pesquisa do Estado de Minas Gerais / O presente trabalho é parte do projeto integrado de tratamento de esgoto e agricultura irrigada do Departamento de Engenharia Agrícola da Universidade Federal de Viçosa (DEA/UFV) e foi desenvolvido com o objetivo de avaliar o desempenho de sistemas de irrigação por gotejamento utilizados na aplicação de esgoto sanitário de lagoa de maturação, bem como identificar os principais fatores de obstrução de gotejadores e verificar a eficiência do tratamento químico na prevenção do entupimento destes. Este trabalho foi realizado na Estação-Piloto de Tratamento de Esgoto (EPTE), localizada numa das áreas experimentais do DEA/UFV, em Viçosa, Minas Gerais. A EPTE foi abastecida com esgoto sanitário bruto de um conjunto residencial, que recebeu tratamento em três etapas. A primeira consistia na remoção dos sólidos de elevada massa específica, por meio de um desarenador. Em seguida, o esgoto sanitário foi disposto sobre faixas cultivadas com capim Tifton 85, para redução da sua carga orgânica. Após o tratamento secundário, o esgoto sanitário foi lançado em lagoa de maturação, com a finalidade de remover os agentes patogênicos presentes. O esgoto sanitário dessa lagoa abasteceu dois sistemas de irrigação por gotejamento, um montado em campo fertirrigando cafeeiros e o outro montado sobre uma plataforma de testes, construída ao lado da lagoa. Durante o período de ensaio, foram realizadas análises físicas, químicas, microbiológicas e hidrobiológicas do esgoto sanitário da lagoa de maturação. O sistema de irrigação montado em campo constou de um filtro de membrana automático autolimpante de 550 mesh e de gotejadores do modelo G1 (não-autocompensante). Fizeram-se quatro avaliações da uniformidade de aplicação de água, nos tempos de funcionamento de 0, 50, 100 e 120 horas, verificando-se, também, a eficiência de remoção dos sólidos suspensos pelo elemento filtrante. O sistema de irrigação montado sobre a bancada de testes constou de quatro unidades de irrigação, cada uma com os modelos de gotejadores: M1 (não-autocompensante), M2 (autocompensante) e M3 (não-autocompensante); todas com filtração comum em filtro de disco de 120 mesh. As unidades de irrigação receberam os seguintes tratamentos: T1, sem aplicação de produtos químicos; T2, com acidificação (pH 6,6) e cloração (0,4 mg L -1 de cloro residual livre); T3, com acidificação (pH 6,6) e cloração (1,0 mg L -1 de cloro residual livre); e T4, com acidificação (pH 6,6) e cloração (1,9 mg L -1 de cloro residual livre). Os produtos químicos foram aplicados por uma hora, a cada 35 horas de funcionamento das unidades de irrigação. As avaliações da uniformidade de aplicação de água foram realizadas a cada 80 horas de funcionamento das unidades de irrigação. Durante o período de ensaio, realizou-se um teste para verificação da eficiência de remoção dos sólidos suspensos pelo elemento filtrante do filtro de disco. As unidades de irrigação funcionaram por um período de 560 horas. Decorrido esse tempo, foram retiradas amostras dos gotejadores para análise, em laboratório, do material causador de entupimento. Diante dos resultados, conclui-se que: o sistema de irrigação por gotejamento montado em campo apresentou decréscimo na uniformidade de aplicação de água ao longo do tempo, devido à obstrução dos gotejadores, mesmo com a utilização de um sistema de filtragem de 550 mesh e a abertura dos finais de linhas a cada duas semanas. Após 120 horas de funcionamento, o modelo de gotejador G1 apresentou reduções no CUC, no CUD e na vazão de 4,49; 10,58; e 4,56%, respectivamente. A uniformidade de aplicação de água também apresentou redução considerável ao longo do período de ensaio no experimento montado sobre a plataforma de testes, que constou de três modelos de gotejadores. Após 560 horas de funcionamento ocorreram reduções nos valores do CUC, do CUD e da vazão dos modelos de gotejadores M1, M2 e M3 de 3,63, 7,50 e 11,86%; de 16,96, 31,98 e 20,18%; e de 12,53, 25,92 e 19,53%, respectivamente. Verificou-se, que o modelo de gotejador M1 foi o mais resistente ao entupimento devido provavelmente, à arquitetura interna de seu labirinto, que manteve um regime de escoamento turbulento suficiente para minimizar a deposição de partículas orgânicas em seu interior. Em média, a eficiência de remoção dos sólidos suspensos foi semelhante à dos filtros de membrana e de disco, sendo algumas comunidades zoo e fitoplanctônicas e larvas de insetos os principais fatores de obstrução dos sistemas de filtragem. O esgoto sanitário da lagoa de maturação apresentou componentes físicos, químicos e biológicos causadores dos entupimentos, com potencial variando de moderado a severo. No entanto, o fator principal de entupimento foi a formação de um biofilme, de coloração verde, resultante da interação entre colônias de bactérias e algas. No experimento montado sobre a bancada de testes, os distintos tratamentos químicos (T2, T3 e T4) mostraram-se eficientes com relação à inibição de bactérias aglomeradoras de partículas orgânicas. No entanto, estudos devem ser conduzidos para uma avaliação precisa da sustentabilidade ambiental do derivado clorado utilizado. / The present work is part of the integrated sewage treatment and irrigated agriculture project of the Universidade Federal de Viçosa’s Agricultural Engineering Department (DEA/UFV). It was developed to evaluate drip irrigation system performances used in the application of sanitary wastewater coming from maturation ponds, as well as to identify dripper clogging main causes and test chemical treatment efficiency in preventing it. The work was carried out at the Sewer Treatment Pilot Plant (EPTE), DEA/UFV’s experimental area, Viçosa, Minas Gerais. EPTE was supplied with raw sanitary sewer from a residential area that was treated in three stages. The first consisted of high specific mass solids removal, by means of a grit tank. Following, the sanitary wastewater was disposed on strips cultivated with Tifton 85 grass, for organic load reduction. After the secondary treatment, wastewater was directed to the maturation pond to remove pathogens. The sanitary wastewater from the pond supplied two drip irrigation systems, one in the field for coffee fertirrigation and the other on top of a test platform, built beside the pond. During the experimental time, the wastewater from the maturation pond was analyzed physically, chemically, microbiologically and hydrobiologically. The system installed in the field consisted of a 550 mesh automatic autocleaning membrane filter and (non-autocompensating) G1 drippers. Four evaluations for uniformity of water application, at the operation times 0, 50, 100 and 120 h were performed, and the efficiency of suspended solids removal by filtering was verified. The irrigation system installed on a test platform consisted of four irrigation units, each with the dripper models: M1 (non-autocompensating), M2 (autocompensating) and M3 (non- autocompensating), all of them with common filtration in a 120 mesh disk filter. The irrigation units had the following treatments: T1, without chemical product application; T2, with acidification (pH 6,6) and chlorination (0,4 mg L -1 of free residual chlorine); T3, with acidification (pH 6,6) and chlorination (1,0 mg L -1 of free residual chlorine); and T4, with acidification (pH 6,6) and chlorination (1,9 mg L -1 of free residual chlorine). The chemical products were applied for one hour, at every 35 hours of irrigation system operation. The evaluations for uniformity of water application were carried out at every 80 hours of system operation. During the experimental time, a test to verify the efficiency of suspended solids removal by the disk filter was carried out. The irrigation units worked for 560 hours. After that time, dripper samples were collected for analysis of the material causing clogging, in laboratory. The results led to the following conclusions: the drip irrigation system installed in the field presented a decrease in the uniformity of water application with the time due to dripper clogging, even using a 550 mesh filtering system and open ends every two weeks. After 120 hours of operation, G1drippers presented reductions in CUC, CUD and in 4,49; 10,58; and 4,56% flow, respectively. The uniformity of water application also had considerable reduction during the experimental period in the experiment installed on the test platform, which consisted of three dripper models. After 560 hours operation, there were reductions in the values of CUC, of CUD and flow of dripper models M1, M2 and M3 of 3,63; 7,50; and 11,86%; of 16,96; 31,98; and 20,18%; and of 12,53; 25,92; and 19,53%, respectively. It was verified that dripper model M1 was the most resistant to clogging probably due to its labyrinth (flow-path) internal architecture, which maintained a regime of turbulent flow enough to minimize internal organic particle deposition. On average, efficiency of suspended solids removal was similar for both the membrane filter and the disk filter, being some zoo and phytoplankton communities and insect larvae the main causes of the filtering system’s clogging. Sanitary sewer derived from the maturation pond presented physical, chemical and biological components causing clogging, varying from moderate to severe potential. However, the main clogging factor was the formation of a green biofilm resultant of the interaction between bacterial and algae colonies. Chemical treatments (T2, T3 and T4) were efficient to inhibit organic particle flocculating bacteria in the experiment installed on the test platform. However, studies ought to be carried out for a precise evaluation of the chlorine product environmental sustainability. / Dissertação importada do Alexandria
194

Avaliação hidrogeológica da interação lagoa - aquífero e da qualidade da água no sistema de filtração em margem da Universidade Federal de Viçosa -MG / Hydrogeological evaluation of pond - aquifer interaction and water quality in the bank filtration system from Federal University of Viçosa - MG

Faria, Agnes Caroline Santos 20 February 2017 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2017-08-09T12:30:20Z No. of bitstreams: 1 texto completo.pdf: 3526777 bytes, checksum: 1f62e755a2bb5751e881c3ed9595278d (MD5) / Made available in DSpace on 2017-08-09T12:30:21Z (GMT). No. of bitstreams: 1 texto completo.pdf: 3526777 bytes, checksum: 1f62e755a2bb5751e881c3ed9595278d (MD5) Previous issue date: 2017-02-20 / Fundação de Amparo à Pesquisa do Estado de Minas Gerais / Na Europa, a utilização da FM para o abastecimento das cidades é bastante comum e antiga (100 anos). No Brasil, o estudo da técnica se iniciou no estado de Santa Catarina em 2006. Em Viçosa, a técnica se iniciou em 2013. Foram utilizados poços de monitoramento previamente instalados a diferentes distâncias da margem da Lagoa da Universidade Federal de Viçosa, nas proximidades do ponto de captação de água das Estações de Tratamento que abastecem a universidade e parte da cidade de Viçosa. O poço de captação foi instalado com o intuito de analisar a dinâmica do fluxo da água subterrânea. A lacuna existente no estudo realizado em 2013, devido à falta de informações da porção mais alta da área, deu origem ao presente trabalho. Portanto, o objetivo dessa pesquisa foi analisar a influência de mais pontos de monitoramento no resultado da modelagem realizada anteriormente e, a qualidade da água do sistema de FM de lagoa para estudos de viabilidade da aplicação da técnica como alternativa efetiva de pré tratamento de água. A análise do fluxo foi realizada por meio do software Visual MODFLOW e a qualidade da água por meio de análises laboratoriais dos parâmetros oxigênio dissolvido, pH, T°, condutividade, turbidez, demanda bioquímica de oxigênio, fósforo total, nitrato, coliformes totais e Escheríchia coli. O modelo numérico foi construído com base no modelo conceitual formulado por meio das medições de nível d’água ao longo de um ano hidrológico, levantamento topográfico, teste de bombeamento, batimetria, condutividade hidráulica, recarga e balanço hídrico. A calibração foi realizada com base no valor do RMS Normalizado que foi igual a 26,73% para o período estacionário sem bombeamento e igual a 23,98% para o período estacionário com bombeamento. Cinco cenários foram simulados a partir do modelo com bombeamento: cenários 1, 2 e 3 considerando uma nova posição do poço de produção com vazões de 120 m3/dia, 150m3/dia e 90m3/dia respectivamente em um período de 43 dias (cenário 1) e 5 anos (cenários 2 e 3). Os RMS Normalizados encontrados para esses cenários foram 23,45%, 24,26% e 23,39%, respectivamente. Os cenários 4 e 5 consideraram o poço de bombeamento no mesmo local, porém com bombeamento de 150m3/dia e 90 m3/dia, resultando em um RMS Normalizado de 24,38% e 24,09%, respectivamente. Com relação às análises de qualidade da água, os resultados demonstram que os parâmetros turbidez, coliformes totais e E. coli foram os que apresentaram valores de remoção mais satisfatórios, com redução de mais de 90% após passagem pelo sistema de filtração em margem. / River bank filtration (RBF) is a simple technique that uses the natural material present on river margins to filter as filtration media. By pumping on a well, water is driven from a river or any water body throughout the sediments on its margins towards the collection well and being filtrated by physical, chemical and biological processes that remove pollutants. In Europe, RBF for urban areas supply have been used for more than 100 years. In Brazil, the study of this technique has began on 2006, Santa Catarina state. In Viçosa, the BF studies started in 2013. Monitoring wells installed at different distances from a pond margin located within Federal University of Viçosa campus. Pumping well was specifically installed for the purposes of the present research. Flow analysis was performed trough Visual Modflow ® and water quality was based on laboratory analysis of the following parameters: dissolved oxygen, HP, temperature, conductivity, turbidity, Oxygen Biochemical Demand (OBD), total phosphorus, nitrate, total coliforms and E. coli. The numerical model was based on a conceptual model developed specifically for this study and supported by: water level measurements during one hydraulic year, pumping test, topography, bathymetry, hydraulic conductivity tests, recharge and water balance. Calibration was performed for Normalized RMS, which was equal to 26.73% for stationary period and equal to 23.98% for pumping period. Five scenarios were simulated from the pumping model: scenarios 1, 2 and 3 considering a new pumping well with 120 m3/day, 150 m3/day and 90 m3/day flow pumping rates during 43 days (scenario 1) and 5 years (scenarios 2 and 3). Normalized RMS found for those scenarios were 23.45%, 24.26% and 23.39%, respectively. Scenarios 4 and 5 have considered a pumping well in the same place as the real tested well, but considering 150 m3/day and 90 m3/daily flow rates, so resulting in Normalized RMS equal to 24.38% and 24.09% respectively. Based on water quality analysis, turbidity, total coliform and E. coli were the one that have presented the best results, with water after river bank filtration presenting a reduction of more than 90% of those parameters when compared to water in the pond.
195

Definição de tecnologias para desaguamento de ultrafinos ricos de minério de ferro : uma aplicação na Vale Carajás - Pará - Brasil

Orsine, Noeber Maciel January 2014 (has links)
O minério de ferro produzido no complexo de Carajás traz consigo características mineralógicas que conferem um elevadíssimo teor de Fe em todas as suas frações granulométricas. Dessa forma, ao final da cadeia produtiva, tanto os produtos comerciais mais grosseiros quanto os finos contem cerca de 62% de Fe contido na sua composição. Importante destacar que em Carajás as fases no processamento desse minério são apenas para cominuição e classificação por tamanho. Não existem etapas de concentração e os produtos são diferenciados por suas respectivas curvas granulométricas: o “granulado” - mais grosseiro (> 13 mm), o “Sinter-Feed” (< 13 mm e > 0,5 mm) e o “pellet feed” (< 0,15 mm). Garantir a correta distribuição granulométrica da matéria prima é uma premissa de mercado. A ultima etapa da classificação é feita através de hidrociclones e gera um overflow ultrafino de altíssima superfície específica maior que 6.500 Blaine e com 45% até 95 % < 7 μm. E ainda possui um elevado teor de Fe - cerca de 62 %. Dessa forma os objetivos gerais dessa pesquisa buscaram a solução para essa oportunidade de recuperar e vender esses rejeitos. O estudo sugeriu através de ensaios com tecnologias capazes de desaguar os ultrafinos gerados para 9,00 % de umidade, que é o valor que permite a movimentação e o manuseio desses rejeitos, além de permitir sua incorporação na blendagem de produtos mais grossos. Desse modo, foram realizados experimentos em diversos laboratórios externos e em escala piloto na Usina de Carajás com amostras dos dois rejeitos ultrafinos das duas fases de hidrociclonagem: o natural e o moído. Ficou evidente que o equipamento tem de combinar necessariamente e de forma eficiente dois fatores essências ao desaguamento: elevadíssimas pressões e altas temperatura na operação desses ultrafinos. A produtividade atingida foi da ordem de 50 t/h x m² para o rejeito da hidrociclonagem do Sinter Feed e 40 t/h x m² para o rejeito dos hidrociclones da Moagem. / The Iron ore that is produced in Carajás mining complex brings mineralogical characteristics that give a very high Fe content in all its size fractions. Thus, at the end of the production chain both coarser and fine contains about 62% Fe contained in its composition. Importantly, in Carajás stages in the processing of this ore are for reduction and classification by size. There is thus no concentration steps and products are differentiated by their respective size distribution curves: the "grain" - coarser (> 13 mm), the "Sinter-Feed" (<13 mm and > 0.5 mm) and the "pellet feed" (<0.15 mm). Ensure proper particle size distribution of the raw material is a market premise. The last step of classification is made using hydrocyclones and generates an overflow ultrafine high specific surface area greater than 6.500 Blaine and with 45% to 95% <7 μm. And has a high Fe content - about 62%. The overall objectives of this research sought the solution to this opportunity to recover and sell these “tailings”. The study suggested by testing with technologies capable of flowing into the ultrathin generated to 9.00% of moisture, which is the value that allows movement and handling these wastes, and allows their incorporation into the blending of thicker products. Thus, experiments were carried out in several external laboratories and pilot-scale plant in the Carajás with samples of both ultrafine “tailings” of the two phases of hydrocycloning: the natural and the ground. It was evident that the equipment must necessarily match and two efficiently factors essences to dewatering: very high pressure and high temperature operation of these “tailings”. The productivity achieved was around 50 t/h x m² in reject of the Sinter Feed hydrocycloning and 40 t/h x m² to reject of the grinding hydrocyclones.
196

Comportamento de filtro plantado horizontal (wetlands construídos) no tratamento de esgoto unifamiliar

Guimarães, Tarcio Moreno Veloso de Andrade January 2013 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2013. / Made available in DSpace on 2014-08-06T17:52:02Z (GMT). No. of bitstreams: 1 322568.pdf: 2253344 bytes, checksum: 5d6bb5acc1500e6445c6dc50adbf7385 (MD5) Previous issue date: 2013 / Filtros plantados com escoamento horizontal subsuperficial (FHSS) são de grande interesse no tratamento de esgoto doméstico, devido à boa eficiência e aos baixos custos de implantação e manutenção. Para o dimensionamento adequado desses sistemas, é necessária uma compreensão sólida dos processos físicos e bioquímicos que se combinam para remover os poluentes. Contribuem nestes processos: solo, microrganismos, plantas e principalmente comportamento hidrodinâmico do fluido dentro do filtro. Considerando a importância da microbiota e do comportamento hidrodinâmico nos processos de tratamento de esgoto em FHSS, além da avaliação da eficiência de tratamento, foi desenvolvido um estudo microbiológico do meio filtrante e um teste com traçador químico (NaCl). É um sistema residencial (4 pessoas; 0,27 m³ dia-1), com tratamento primário em tanque séptico, seguido de um FHSS. Foram avaliados os principais parâmetros físico-químicos e biológicos do esgoto na entrada e na saída do sistema. No meio filtrante, foram avaliadas as concentrações de bactérias heterotróficas, sólidos voláteis e microrganismos visualizados por microscopia. O FHSS apresentou, ao longo de 17 meses, eficiência satisfatória, removendo, em média, 18,7 e 3,2 g m² dia-1 de DQO e sólidos suspensos, respectivamente, o que corresponde a eficiências de 80%. Com relação à microfauna avaliada no leito filtrante, os microrganismos mais abundantes foram os ciliados, seguidos por nematoides. A concentração de microrganismos foi correlacionada positivamente com a concentração de matéria orgânica e de oxigênio. No teste com traçador foi obtida uma eficiência volumétrica de 1,14 e um tempo de detenção hidráulico médio de aproximadamente 5 dias. Foi obtido um valor de 0,02 para o número de dispersão (d). Os valores obtidos para os coeficientes de cinética de primeira ordem de remoção de DQO, para os modelos clássicos aplicados aos dados do FHSS foram de 0,35 ? 0,44 d-1. Estes dados contribuem para o dimensionamento de filtros plantados, preenchidos com areia, aplicados em escala residencial para o tratamento de esgotos. <br>
197

Produção e caraterização de filtro para purificação de água a partir de cinza de casca de arroz impregnada com nanopartículas de prata

Contreras, Angela Maria Gutierrez January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Ciência e Engenharia de Materiais, Florianópolis, 2014. / Made available in DSpace on 2015-02-05T20:11:29Z (GMT). No. of bitstreams: 1 331230.pdf: 9468315 bytes, checksum: b77073bdc61d8ce18697a06ae2b3ec9b (MD5) Previous issue date: 2014 / Neste trabalho caracterizou-se uma cinza de casca de arroz(CCA) impregnada com nanopartículas de prata para utilização em filtros de água. As características do material obtido foram comparadas com um carvão ativado comercial, vendido para filtros de água por gravidade. Foram feitas caracterizações como granulometria, área superficial, permeação ao escoamento do ar, simulação de escoamento com água, da cinza in natura assim como do carvão comercial. Após as impregnações, os materiais foram caracterizados mediante MEV, BET e índice de hidrofobicidade. Foi criado um sistema de filtração para testar o material em condições de operação próximas à realidade e quantificara lixiviação de prata e a ação bactericida. Os resultados obtidos indicam que o material tem um alto potencial para utilização em filtros de água. A cinza com partículas entre 0.140-1.180 mm e impregnadas com 0.5%(w/w) de nanopartículas de prata apresentou boas características como de área superficial, coeficiente de uniformidade, permeabilidade e ação bactericida. Parâmetros como a concentração de prata na água após a filtração podem ser diminuídos com a diminuição da vazão para estarem dentro da legislação.<br> / Abstract: In this study the rice husk ash (RHA) impregnated with silver nanoparticles was characterized and the possible use in water filters was evaluated. The characteristics of the material obtained were compared to a commercial activated carbon, commonly sold for gravity water filters. Particle size, surface area, permeation of the air flow and simulation with water flow were performed for the ash as received, as well as for the commercial activated carbon. After impregnation, samples were characterized by SEM, BET and hydrophobicity. A filtration system was designed to test the material in conditions close to reality operation in order to quantify silver leaching and bactericidal action. The obtained results indicate that the material has a high potential for use in water filters. The ash particles between 140-1180 mm impregnated with 0.5%(w/w) of silver nanoparticles showed suitable values of surface area, uniformity coefficient, permeability and bactericidal action. Parameters such as silver concentration in water after filtration can be decreased with the decrease of flow to be within the regulations.
198

Prevalência de disfunção renal em uma coorte ambulatorial com HIV/AIDS no Rio de Janeiro

Silva, Patrícia Santiago da January 2011 (has links)
Made available in DSpace on 2014-08-11T12:37:23Z (GMT). No. of bitstreams: 4 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) patricia_silva_ipec_mest_2011.pdf: 545134 bytes, checksum: f06b67e6fb79e3263200f9e58d6683ad (MD5) 69480.pdf.txt: 149501 bytes, checksum: 280e7248c98784f304553c91546659f1 (MD5) 69480.pdf.jpg: 1231 bytes, checksum: 7fa238cba3dfd3bcdf913cc2fd49bd1f (MD5) Previous issue date: 2014-05-07 / Fundação Oswaldo Cruz. Instituto Nacional de Infectologia Evandro Chagas. Rio de Janeiro, RJ, Brasil / Introdução: o surgimento da terapia antirretroviral de alta potência mudou a história da infecção pelo HIV, permitindo o aumento da sobrevida dos pacientes e a mudança da característica da doença de infecção aguda e letal para comorbidade crônica. A doença renal destes pacientes também mudou, tomando perfil crônico também. Objetivos: investigar a prevalência de disfunção renal, definida como TFGe menor que 60 ml/min e determinar os fatores associados Métodos: estudo de coorte, retrospectivo e transversal, através do cálculo da taxa de filtração glomerular estimada pela equação CKD-EPI avaliando dados demográficos e clínicolaboratoriais de pacientes do IPEC Resultados: a prevalência foi 3,8%. Os fatores associados foram faixa etária maior que 50 anos, contagem de linfócitos T CD4+ menor que 350 cels/mm3 no momento da dosagem da creatinina, presença de diabete melito ou hipertensão arterial sistêmica, uso prévio de tenofovir, uso prévio de indinavir e uso corrente de lopinavir ou atazanavir. Conclusão: a prevalência encontrada foi baixa. Alguns antirretrovirais apresentam potencial nefrotóxico porém este parece ser manejável através da vigilância clínico-laboratorial estrita / Introduction : Highly active antiretroviral therapy (HAART) chan ged the course of HIV infection, allowing longer survival and altering the face of AIDS from an acute lethal disease to a chronic condition. Kidney disease among those patients changed at the same time, becoming also of a more chronic character. Objectives : to investigate the prevalence of kidney dysfunction, defined as eGFR of less than 60 ml/min and to establish associated factors Method : We performed a retrospective cross - sectional study. We obtained eGFR values by the CKD - EPI equation and analyzed demog raphics and clinical and laboratorial of our patients. Results : the prevalence found was 3,8%. Associated factors were age over 50 years old, less 350 T CD4 linfocite cels/mm3 at the moment of creatinina measurement, diabetes, hypertension, past tenofovir use, past indinavir use, current use of atazanavir or lopinavir. Conclusion: Prevalence was considered low. Some antiretroviral drugs showed nephrotoxic potential but it appears to be acceptable under strict clinical and laboratorial follw - up.
199

Filtração em sedimento do mar como pré-tratamento a osmose inversa

Burgardt, Tiago January 2017 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2017 / Made available in DSpace on 2017-12-05T03:10:48Z (GMT). No. of bitstreams: 1 348709.pdf: 3964500 bytes, checksum: 8bebce1c703a66ee3e00b002b3c99b45 (MD5) Previous issue date: 2017 / É crescente a preocupação mundial com relação à carência dos recursos hídricos em função da poluição por processos antrópicos e do crescimento populacional desenfreado. A água doce em sua forma potável é um recurso encontrado em situação de escassez em algumas regiões. Dessa forma, fontes alternativas como a água dos oceanos (salinidade superior a 30?) são opções à falta de água doce (salinidade inferior a 0,5?). Para tornar-se própria ao consumo humano, a água dos oceanos necessita sofrer o processo de dessalinização. Esse processo pode ser realizado por meio de técnicas de separação térmica ou técnicas de separação por membrana, ambas são classificadas como não convencionais. Dentre as técnicas de separação por membranas destaca-se a Osmose Inversa (OI). Um fator preponderante na utilização correta deste tipo de membranas é a adequação da água utilizada a níveis de qualidade satisfatórios às membranas de OI. Dentro deste contexto, a presente dissertação tem por objetivo avaliar a técnica de filtração em areia de praia, como um pré-tratamento à OI na produção de água potável. A técnica tem o intuito de preparar a água para as membranas de OI, utilizando a areia do mar como meio filtrante. Dessa forma, foram analisados dois sistemas de captação de água salina: um poço de captação vertical e um sistema de captação angular, ambos situados na Barra da Lagoa, Município de Florianópolis, SC. Foram realizadas análises da água bruta e da água após a filtração nos bancos de areia pelos dois sistemas. A caracterização da água foi feita por meio da análise de parâmetros físico-químicos, SDI (silt density index) e óleos e graxas. O sistema de captação vertical não apresentou resultados satisfatórios às membranas de OI, uma vez que a mistura da água salina com o lençol de água doce provocou um aumento nos parâmetros que relacionam a quantidade de matéria orgânica na água produzida. Este fato que pode ser verificado pela cor verdadeira que apresentou valores entre 100 e 550 uH e o carbono orgânico dissolvido que apresentou valores entre 5 e 16 mg.L-1. Por sua vez, o sistema de captação angular apresentou remoção maior de sólidos suspensos com média de 0,15 uT e 5,3 uH para turbidez e cor aparente, respectivamente. O sistema de filtração angular também apresentou remoção de 16,25% para o carbono orgânico dissolvido e nesta pesquisa apresentou resultados de qualidade mais satisfatórios quando comparado ao sistema vertical. / Abstract : Considering the global concern about the scarcity of fresh water due to pollution by human activity and unbridled population growth, fresh water proper to human consumption is a natural resource found in shortage. Thus, others sources such as ocean water (salinity above 30?) shows as alternative to lack of fresh water (salinity less than 0,5?). To become proper for human consumption oceans water need to be treated by desalination process. This process can be carried out by thermal separation techniques or membrane separation techniques, both processes uses non-conventional processes for water treatment. Among the desalination techniques, the Reverse Osmosis (RO) shows as one of the main ways in obtaining fresh water. A preponderant factor in the correct use of this type of technology, is the adequacy of the raw water to required quality levels of RO membranes. In this context, the present dissertation aims to evaluate the technique of sand beach filtration, as a pretreatment to RO membranes in the production of drinking water. The technique of sand beach filtration is used to produce water for RO membranes, using the sea sand as filter media. In this way, two systems of saline water abstraction will be analyzed: a vertical abstraction well and a horizontal abstraction system, both located in Barra da Lagoa, Florianópolis, SC. Raw water and water analysis will be carried out after filtration in the sandbanks by the two systems. The characterization of the water will be done through the analysis of physical-chemical parameters, SDI (silt density index) and oils and greases. The vertical intake system did not present satisfactory results to the OI membranes, while the blending saline water with the under groundwater caused an increase in the parameters that relate the amount of organic matter in the water produced by the well. This fact can be verified by the true color that presented values between 100 and 550 uH and the dissolved organic carbon that presented values between 5 and 16 mg.L-1. In turn, the angular intake system showed efficient removal of suspended solids and also more stable results over time. This fact can be verified by turbidity and apparent color, which presented a mean of 0.15 uT and 5.3 uH, respectively. The angular filtration system also presented removal of 16,25% for dissolved organic carbon and in this research presented more satisfactory quality results when compared to the vertical system.
200

Análise da prevalência de alteração de taxa de filtração glomerular estimada em hipertensos atendidos na atenção primária do município de Vitória -ES / Analysis of the prevalence of rate change of glomerular filtration rate estimated in hypertensive patients attended in primary care in the Municipality of Vitória - ES

Passigati, Cynthia Perin 01 June 2011 (has links)
Made available in DSpace on 2016-12-23T13:47:03Z (GMT). No. of bitstreams: 1 Cynthia Perin Passigatti.pdf: 366338 bytes, checksum: 084edc0a5b10356be00af24199b3c65f (MD5) Previous issue date: 2011-06-01 / Hypertension is the main cause of chronic kidney disease in Brazil and as monitoring of renal function, it is used the estimation of glomerular filtration rate (GFR), because early detection of kidney disease becomes the most important measure to delay the progression of the disease, mainly among those considered risk groups such as hypertensives. The study aims to estimate the GFR by means of the Cockcroft-Gault equation and to investigate the consonance among the Cockcroft-Gault, the corrected Cockcroft-Gault for obese and the abbreviated-MDRD equations in hypertensive patients attended by the primary health care service in the city of Vitória - ES. It is a transversal study of secondary data, observational, with 754 hypertensive patients attended in health facilities in 2009. For statistical analysis, there has been used the chisquare test and the consonance among the equations has been analyzed by means of the Kappa statistics test. Patients were predominantly female (67.2%), overweight (73.7%) and uncontrolled blood pressure (56.9%). The average age was 58.18 years (±13.52) and the serum creatinine (SCr) 0.81 mg / dl (± 0.28). The prevalence of reduced GFR was 19% when from 30 to 59 ml/min and 1.6% when from 29 to 15 ml/min and was 15 times higher in the elderly, 4.93 times higher in those with elevated SCr, 2.19 times in low-weight hypertensives and 1.6 times more prevalent in men. There was reasonable, moderate and strong consonance among the Cockcroft-Gault and MDRD, the corrected Cockcroft-Gault and MDRD and Cockcroft-Gault and the corrected Cockcroft-Gault equations, respectively, despite using different parameters / A hipertensão é a principal causa de doença renal crônica no Brasil e como monitorização da função renal, utiliza-se a estimativa da filtração glomerular (FG), pois a detecção precoce da doença renal torna-se a medida mais importante para retardar a progressão da doença, principalmente entre os considerados grupos de risco como hipertensos O estudo objetiva investigar a função renal de hipertensos atendidos na atenção primária do município de Vitória ES e três diferentes equações utilizadas para estimar a taxa de filtração glomerular. Trata-se de estudo transversal de dados secundários, observacional, com 754 hipertensos atendidos nas unidades de saúde, em 2009. Para análise estatística, utilizou-se o teste qui-quadrado e a concordância entre as equações foi analisada mediante teste Kappa. Houve predominância do sexo feminino (67,2%), excesso de peso (73,7%) e pressão arterial não controlada (56,9%). A média de idade foi de 58,18 anos (±13,52) e da creatinina sérica (CrS) 0,81mg/dl (±0,28). A prevalência da FG reduzida foi de 19% quando de 30 a 59ml/min e 1,6% quando de 29 a 15ml/min e apresentou-se 15 vezes maior em idosos, 4,93 vezes maior naqueles com CrS elevada, 2,19 vezes nos hipertensos com baixo peso e 1,6 vez mais prevalente em homem. Houve razoável, moderada e forte concordância entre as equações de Cockcroft-Gault e MDRD, Cockcroft-Gault corrigida e MDRD e Cockcroft-Gault e Cockcroft-Gault corrigida, respectivamente, apesar de utilizarem parâmetros distintos. Esses resultados mostram a importância de monitorar a função renal com vistas à intervenção precoce e retardamento da perda de função renal em hipertensos

Page generated in 0.0675 seconds