• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 243
  • 11
  • 11
  • 11
  • 11
  • 10
  • 6
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 255
  • 130
  • 110
  • 98
  • 68
  • 58
  • 58
  • 57
  • 49
  • 44
  • 38
  • 29
  • 29
  • 29
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Desempenho e características de fundos de investimentos em renda fixa investidos por regimes próprios de previdência social

Almeida, Bernardo Kurka de 13 December 2016 (has links)
Submitted by BERNARDO KURKA DE ALMEIDA (berkurka@hotmail.com) on 2017-04-20T00:02:44Z No. of bitstreams: 1 Almeida 2016 DESEMPENHO E CARACTERÍSTICAS DE FUNDOS DE INVESTIMENTO.pdf: 1958642 bytes, checksum: cddadc2869adc1146cb51042029fdae4 (MD5) / Approved for entry into archive by GILSON ROCHA MIRANDA (gilson.miranda@fgv.br) on 2017-04-20T12:04:52Z (GMT) No. of bitstreams: 1 Almeida 2016 DESEMPENHO E CARACTERÍSTICAS DE FUNDOS DE INVESTIMENTO.pdf: 1958642 bytes, checksum: cddadc2869adc1146cb51042029fdae4 (MD5) / Made available in DSpace on 2017-04-20T12:31:41Z (GMT). No. of bitstreams: 1 Almeida 2016 DESEMPENHO E CARACTERÍSTICAS DE FUNDOS DE INVESTIMENTO.pdf: 1958642 bytes, checksum: cddadc2869adc1146cb51042029fdae4 (MD5) Previous issue date: 2016-12-13 / This work analyses the performance, characteristics and persistence of Brazilian bond-funds, that received investments from Regimes de Próprios de Previdência Social (BaseRPPS). Their performance was compared with a sample that contains all bond-funds with CVM classification equal to Fixed Income that are not exclusive and not levareged (BaseRF). The study analyses the characteristics that are present among the top and worst performance funds. The efficiency of fund selection utilizing Sharpe Index was also analyzed. Most literature on performance evaluation have involved stock funds or mutual funds and not bond-funds exclusively. Blake, Elton e Gruber (1993) was one of the first works exclusively on bond-funds. In brazil, most of the exclusive bond funds work have explored models to explain funds returns utilizing different indexes, a smaller number of work explore performance and characteristics. Sample BaseRPPS consists in 282 funds and sample BaseRF contains 1338 funds. The performance evaluation was done using Sharpe Index with CDI as a risk-free benchmark. The results are similar to those found by Rocha (2013), Amaral (2013) e Medeiros (2015). The results are compatible with Market Efficiency, on average the funds did not exceed the risk-free index. Funds of the BaseRPPS sample achieved marginally higher performance then BaseRF sample. Fund characteristics such as size, minimum application value, private bonds and inflation indexation presented positive correlation with best performing funds. Fund fees, number of investors in the fund, fund age and fund classification as fund of fund 'FIC' were negative correlated. The fund selection analysis was made using ex-post information. In each year, ten portfolios where created based on the previous year fund characteristic rankings. Portfolio that selected the highest Sharp Index ratio funds was superior then portfolios that selected highest returns or smallest cost fees. The amount of funds persisting with low Sharp Index on the following year was higher than the amount of funds persisting with high Sharpe Index. The amount of fund closing or merging was twice among the funds in the worst performing portfolio than in the funds among the best portfolio. The portfolio witch selected the 10% lowest cost fees, performed better than the risk free index, on avarege 91% of the funds remained in the portfolio on the following year. / O objetivo deste trabalho é avaliar o desempenho, características e persistência de performance de fundos de investimento em renda fixa investidos por Regimes Próprios de Previdência Social (BaseRPPS). O desempenho foi comparado com uma base que contém todos os fundos classificados na Comissão de Valores Mobiliários (CVM) como Renda Fixa, não exclusivos e não alavancados (BaseRF). Também foi avaliado a eficiência do Índice Sharpe para a seleção de fundos. A maior parte da literatura relacionada a desempenho de fundos é direcionada a fundos de ações ou multimercados. A pesquisa de Blake, Elton e Gruber (1993) foi uma das primeiras que utilizou somente fundos de renda fixa. Entre os trabalhos exclusivos com fundos de renda fixa no Brasil, grande parte explorou a análise de estilo dos retornos, e um menor número analisou a performance e características dos fundos. O primeiro grupo analisado, BaseRPPS, contém 282 fundos e o grupo BaseRF contém 1338. O período analisado foi de 2010 a 2015 inclusive. O desempenho foi avaliado pelo Índice de Sharpe (IS), utilizando o CDI como ativo livre de risco. Através da classificação das observações em grupos de acordo com o decil de performance, foi analisado quais características estão presentes entre os fundos de melhor e pior performance. Os resultados são similares aos encontrados por outros autores, como: Rocha (2013), Amaral (2013) e Medeiros (2015). Esses resultados são compatíveis com a eficiência de mercado. Em média, os fundos não superaram o ativo livre de risco. Fundos do grupo BaseRPPS obtiveram IS marginalmente superior aos fundos do grupo BaseRF. Características como: patrimônio líquido, valor mínimo de aplicação, crédito privado e indexação em índices de inflação apresentaram correlação positiva com o IS. Por sua vez, taxa de administração, quantidade de cotistas, idade do fundo e classificação igual a fundo de investimento em cotas (FIC) apresentaram correlação negativa com o IS. A estratégia de seleção de carteiras de fundos utilizando informações do ano anterior e re-balanceamento após um ano foi testada. A seleção de fundos por maiores valores de IS obteve melhor desempenho do que a seleção por retorno líquido ou taxa de administração. Dentre os fundos com melhores IS, a proporção de fundos que mantiveram o decil de desempenho no ano seguinte foi de 45%, ente fundos de piores IS a proporção foi de 78%. A carteira que selecionou fundos com 10% menores taxas de administração superou o retorno do CDI acumulado no período, a proporção de fundos que se mantiveram na carteira de melhor desempenho no ano seguinte foi de 91%.
122

Influência do método de aquecimento de revestimentos fosfatados sobre sua resistência à compressão e sobre a rugosidade de superfície e estabilidade dimensional de ligas de Ni-Cr e Ni-Cr-Ti

Zequetto, Michele Marques [UNESP] 24 March 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-03-24Bitstream added on 2014-06-13T20:06:15Z : No. of bitstreams: 1 zequetto_mm_dr_araca.pdf: 383469 bytes, checksum: 3fd20e10aa2c413edb650399efcff201 (MD5) / No processo de fundição pela cera perdida, os materiais envolvidos podem apresentar interações entre si e o de tempo despendido para se obter as estruturas metálicas é oneroso. Assim, o objetivo deste trabalho foi avaliar a influência da propriedade física de resistência à compressão de revestimentos fosfatados indicados para altas temperaturas de fundição, utilizando os métodos de aquecimento convencional (MAC) e rápido (MAR), e analisar a rugosidade de superfície e a alteração dimensional do produto final da fundição (a peça metálica) obtido com as ligas metálicas Ni-Cr (Verabond II) e Ni-Cr-Ti (Fit Cast Titanium). Os revestimentos estudados Castorit Super C, Castorit All Speed, Heat Shock e Micro Fine 1700 foram vazados em uma matriz de silicone que permitiu obter amostras com formato cilíndrico (n=200), medindo 10mm de diâmetro e 20mm de comprimento. A resistência (MPa) deles foi determinada à temperatura ambiente (resistência fria) após 15, 30 e 60 minutos de manipulação, e também imediatamente após serem submetidos aos métodos de aquecimento MAC e MAR (resistência de queima), por meio de uma máquina de ensaio universal, em velocidade de 0,05mm/min e carga de 150kgf. Após inclusão, aplicação dos métodos de aquecimento e fundição às amostras (n=120) para rugosidade de superfície (Ra-μm), foram avaliadas por um rugosímetro Mitutoyo Surftest SJ-401 com cut-off de 0,8mm e três repetições em cada amostra. A alteração dimensional foi determinada pela diferença entre os valores dimensionais da cera e da peça fundida (n=60) utilizando-se o software AutoCad2008. Os valores médios obtidos foram submetidos à análise de variância (ANOVA) e ao teste de Tukey (p<0,05), apresentando os valores de resistência à compressão diferentes entre os revestimentos (Heat Shock os valores maiores) e entre os tempos de mensuração em relação... / In the lost wax casting procedure, the involved materials can present interactions among them and the time used to obtain the metallic structures is onerous. Thus, the purpose of this study was to evaluate the influence of the compressive strength physical property of phosphate-bonded investment materials indicated for high casting temperatures, utilizing conventional heating (CHM) and quick heating methods (QHM), and analyze the surface roughness and the dimensional accuracy of the final casting product (the metallic piece) obtained from Ni-Cr (Verabond II) and Ni-Cr-Ti (Fit Cast Titanium) metallic alloys. Castorit Super C, Castorit All Speed, Heat Shock and Micro Fine 1700 investment materials were poured into a silicone matrix in order to obtain cylindrical samples (n=200), measuring 10mm in diameter and 20mm in length. Their strength (MPa) was determined at room temperature (green strength) after 15, 30 and 60 minutes of manipulation, and also immediately after being submitted to the CHM and QHM heating methods (fired strength), by means of an universal testing machine at 0,05mm/min speed and 150kgf load. After investing, applying the heating methods and casting the samples (n=120) for surface roughness (Ra), the samples were evaluated with a Mitutoyo Surftest SJ-400 profilometer with 0,8mm cut-off, three times in each sample. The dimensional accuracy was determined by the difference among the dimensional values of the wax and of the metallic piece (n=60) through the software AutoCad2008. The mean values obtained were submitted to ANOVA and Tukey tests (p <0.05), and the results showed that the values of compressive strength were different among the investment materials (Heat Shock presenting the highest values) and among the analysis times with a direct relation of time and strength increase, but there was no difference between CHM and QHM. Moreover, it was observed no differences... (Complete abstract click electronic access below)
123

Estimation of random coefficients logit demand models: an application to the Brazilian fixed income fund market

Castilho, Rafael de Braga 29 October 2013 (has links)
Submitted by Rafael de Braga Castilho (rcastilho@fgvmail.br) on 2014-01-06T19:10:15Z No. of bitstreams: 1 MestRafaelCastilho.pdf: 636676 bytes, checksum: f815c7fac86fe9684f4f79cd86ec9f26 (MD5) / Approved for entry into archive by Janete de Oliveira Feitosa (janete.feitosa@fgv.br) on 2014-01-15T17:51:37Z (GMT) No. of bitstreams: 1 MestRafaelCastilho.pdf: 636676 bytes, checksum: f815c7fac86fe9684f4f79cd86ec9f26 (MD5) / Approved for entry into archive by Marcia Bacha (marcia.bacha@fgv.br) on 2014-01-24T12:33:06Z (GMT) No. of bitstreams: 1 MestRafaelCastilho.pdf: 636676 bytes, checksum: f815c7fac86fe9684f4f79cd86ec9f26 (MD5) / Made available in DSpace on 2014-01-24T12:33:23Z (GMT). No. of bitstreams: 1 MestRafaelCastilho.pdf: 636676 bytes, checksum: f815c7fac86fe9684f4f79cd86ec9f26 (MD5) Previous issue date: 2013-10-29 / Estimation of demand and supply in differentiated products markets is a central issue in Empirical Industrial Organization and has been used to study the effects of taxes, merges, introduction of new goods, market power, among others. Logit and Random Coefficients Logit are examples of demand models used to study these effects. For the supply side it is generally supposed a Nash equilibrium in prices. This work presents a detailed discussion of these models of demand and supply as well as the procedure for estimation. Lastly, is made an application to the Brazilian fixed income fund market. / Estimação de demanda e oferta em mercados com produtos diferenciados é uma questão central em organização industrial empírica e tem sido usada para estudar os efeitos de taxas, fusões, introdução de novos bens, poder de mercado, dentre outros. Logit e Logit com coeficientes aleatórios são exemplos de modelos de demanda utilizados para estudar estes efeitos. Para a oferta geralmente é suposto equilíbrio de Nash em preços. Este trabalho apresenta uma discussão detalhada destes modelos de demanda e oferta, assim como o procedimento para estimação. Por fim é feita uma aplicação para o mercado brasileiro de fundos de renda fixa.
124

Análise das tensões geradas por implantes curtos e convencionais reabilitados com próteses fixas unidas e isoladas, por meio do método de correlação de imagem digital / Analysis of the stresses generated by short and conventional implants rehabilitated with splinted and non-splinted fixed prosthesis by digital image correlation method

Peixoto, Raniel Fernandes 06 December 2013 (has links)
Nos casos de perda óssea vertical severa, principalmente em áreas posteriores da mandíbula, o uso de implantes curtos associado a próteses fixas metaloplásticas esplintadas pode ser uma alternativa às cirurgias de enxerto ósseo e a melhor transmissão de tensões ao osso adjacente, respectivamente. Dentre os métodos que avaliam a distribuição de tensões em torno dos implantes, a Correlação de Imagem Digital (CID) leva vantagens no que diz respeito à possibilidade de avaliar a distribuição das tensões de forma contínua por meio de imagens obtidas ao longo do tempo, durante carregamento oclusal. Diante disso, este trabalho avaliou qualitativa e quantitativamente o desempenho biomecânico de próteses fixas metaloplásticas parafusadas, unidas e isoladas, sobre implantes de diferentes comprimentos, posicionados na região posterior da mandíbula, por meio do método de CID. A partir de quatro modelos mestres, foram confeccionados quatro modelos em resina de poliuretano F16, simulando extremidade livre mandibular, com o dente 44 em resina (Luxatemp) e os dentes 45, 46 e 47 substituídos por implantes curtos (4 x 5 mm) e/ou convencionais (4 x 11 mm). Os grupos (G) deste estudo foram: G1 (dois implantes convencionais [45 e 46] e um curto [47]), G2 (um implante convencional [45] e dois curtos [46 e 47]), G3 (três implantes curtos) e G4 (três implantes convencionais). Próteses fixas metaloplásticas unidas e isoladas foram parafusadas sobre os intermediários e submetidas a diferentes carregamentos oclusais de 250N: puntiforme (distal do 47 e mesial do 45) e oclusal distribuído. Tensões na direção horizontal (&epsilon;xx) foram calculadas e comparadas qualitativa e quantitativamente pelo software de CID (Davis 8.0, LaVision GmbH). Em geral, houve uma concentração de tensões em maior intensidade nas áreas onde os implantes curtos estavam posicionados. No carregamento puntiforme no segundo molar, houve uma predominância de tensões de compressão e tração nos planejamentos com coroas unidas e isoladas, respectivamente, e as tensões de maior magnitude foram encontradas no G2, G3 e G4 com coroas isoladas (p>0,05), apresentando valores mediados (&mu;S) equivalentes a 396,08, 360,45 e 354,04, respectivamente. No carregamento puntiforme envolvendo o segundo pré-molar, houve predominância de tensões de compressão em todos os planejamentos, com magnitudes mais elevadas nos grupos com coroas unidas (p<0,05). As simulações com carga oclusal distribuída revelaram, também, predominância de tensões de compressão em todos os planejamentos, com maior magnitude nos grupos com coroas unidas, sobretudo no G1 (-464,05±106,43) e G3 (-474,39±179,54) e com diferenças estatisticamente significantes em relação aos demais grupos (p<0,05). Dentro das limitações deste estudo, pode-se concluir que a esplintagem das coroas sobre múltiplos implantes promoveu maior concentração de tensões em torno dos implantes durante os carregamentos puntiforme no segundo pré-molar e oclusal distribuído, reforçando a necessidade de contato interproximal e ajuste oclusal efetivos para promover melhor distribuição das tensões. Adicionalmente, a combinação de implantes curtos e convencionais parece ser uma alternativa viável na reabilitação de áreas edêntulas posteriores com altura óssea reduzida. / In cases of severe vertical bone loss, especially in the posterior region of the mandible, the use of short implants associated with splinted resin-veneered fixed dental prostheses (FDPs) can be an alternative to bone graft surgery and better force transmission to the adjacent bone, respectively. Among the methods to evaluate the stress distribution around the implants, the digital image correlation (DIC) has advantages as regards the possibility of evaluating the stress distribution continuously using images taken over time, during occlusal loading. Thus, this study evaluated qualitatively and quantitatively the biomechanical behavior of splinted and non-splinted resin-veneered FDPs, screw-retained on implants of different lengths positioned in the posterior region of the mandible with the aid of the DIC method. Four F16 polyurethane resin models were fabricated to simulate half of the mandibular arch containing tooth 44 in resin (Luxatemp) and teeth 45, 46 and 47 replaced by short (4 x 5 mm) and/or conventional (4 x 11 mm) implants. Groups (G) of this study were: G1 (two conventional implants [45 and 46] and one short implant [47]), G2 (one conventional implant [45] and two short implants [46 and 47]) G3 (three short implants) and G4 (three conventional implants). Splinted and non-splinted FDPs were screwed to the implant abutment and subjected to different oclusal loads of 250N: punctiform (45 mesial and 47 distal) and balanced occlusal load. Strains in the horizontal direction (&epsilon;xx) were calculated based on displacement and compared qualitatively and quantitatively by the DIC software (Davis 8.0, LaVision Inc.). In general, there was a stress concentration at higher intensity in those areas where short implants were placed. In punctiform load on the second molar, there was a compressive and tensile stresses predominance when splinted and non-splinted crowns were used, respectively, and the stresses of greater magnitude were found in the G2, G3 and G4 with non-splinted crowns (p>0.05), showing median values (&mu;S) equivalent to 396.08, 360.45 and 354.04, respectively. In punctiform load involving the second premolar, there was a compressive stress predominance in all planning with highest magnitudes in groups with splinted crowns (p<0.05). The oclusal load distributed simulations also revealed compressive stresses predominance in all planning, with greater magnitude in groups with splinted crowns, especially in G1 (-464.05 ± 106.43) and G3 (-474.39 ± 179.54), both with statistically significant differences when compared to the other groups (p<0.05). Within the limitations of this study, it can be concluded that splinting multiple adjacent implant supported provided a high stress concentration around the implants during punctiform (45 mesial) and balanced occlusal load, reinforcing the need for effective interproximal contact and oclusal adjustment to promote better stress distribution. Additionally, the combination of short and conventional implants seems to be a viable alternative in the rehabilitation of mandibular free end with reduced bone height.
125

"Moldagem em prótese parcial fixa com afastamento gengival: estudo histológico comparativo em cães entre a técnica de anel de cobre e godiva e cordão de algodão associado a cloreto de alumínio" / FIXED PARTIAL DENTURE IMPRESSION WITH GINGIVAL DISPLACEMENT: COMPARATIVE HISTOLOGICAL STUDY IN DOGS USING COPPER BAND TECHNIQUE AND STRING IMPREGNATED WITH ALUMINIUM CHLORIDE

Santos, Lydia de Brito 07 May 2002 (has links)
O presente estudo submeteu três cães ao afastamento gengival comparando a técnica de afastamento e moldagem com anel de cobre e godiva de baixa fusão com a técnica de afastamento gengival com cordão de algodão associado a cristais de cloreto de alumínio, e moldagem única com silicona de condensação. O objetivo foi comparar a biocompatibilidade periodontal entre as duas técnicas. Foram obtidas amostras nos períodos de 0 (zero), 3, 7, 14 e 21 dias, as quais foram avaliadas histologicamente, utilizando-se a técnica de coloração hematoxilina e eosina. Como resultado, para todos os métodos testados, as conseqüências histológicas para o periodonto foram consideradas reversíveis. / This study carried out three dogs to gingival displacement comparing the copper band and compound gingival displacement and impression technique with string impregnated in aluminium chloride with gingival displacement technique, and single impression by condensing silicone impression material. The objective was to compare the periodontal biocompability between the two techniques. Blocks specimens including the teeth and the soft tissue were taken immediately, 3, 7, 14 e 21 days, and had histological analysis with stain hematoxilin and eosin. The results showed that all groups had reversible histological consequences.
126

O mercado de eurobonds e as captações brasileiras: uma abordagem empírico-descritiva / The Eurobond market and the Brazilian issues: an empirical and descriptive approach

Pimentel, Renê Coppe 24 November 2006 (has links)
O financiamento por meio de títulos negociáveis vem ganhando importância no cenário internacional e concorrendo com meios tradicionais de financiamento, como os empréstimos bancários. No entanto, existem poucos estudos científicos no Brasil que abordam o financiamento das empresas por meio da emissão de títulos de dívida, em especial, os títulos de dívida de médio e longo prazos emitidos no exterior, os eurobonds e euronotes. Dessa forma, este trabalho tem por objetivo analisar e descrever o mercado de eurobonds e euronotes, sua história, características, ferramentas e técnicas, com especial atenção aos títulos brasileiros. Este objetivo será atingido por meio de uma análise descritivo-exploratória e o estabelecimento de relações entre variáveis, revisão de literatura, apresentação e exposição de dados históricos de mercado, análise de volumes de emissões e desenvolvimento intertemporal. Também é objetivo deste trabalho analisar empiricamente, de forma descritiva e exploratória, o perfil das empresas brasileiras que captam no exterior e a utilização de bonds em sua estrutura de financiamento, com suporte das teorias de estrutura de capital do trade-off estático e de peking order. Para isso, foram feitas análises estatísticas de indicadores contábeis e financeiros organizados em forma de painel (painel data analysis). Os resultados empíricos demonstram que, em geral, as empresas que emitem bonds possuem maior alavancagem com capital de terceiros, perfil de dívida com prazo mais alongado, maiores índices de imobilização, maior taxa de rentabilidade derivada do elevado faturamento, o que demonstra também a diferença do tamanho médio das empresas com emissão de bonds com as demais, confirmando a afirmação de Valle (2001) de que apenas as grandes empresas brasileiras possuem atuação ativa na captação no mercado de eurobonds e bonds estrangeiros. Também foi verificado que o comportamento dos indicadores financeiros em relação ao endividamento por bonds está em acordo com as teorias da estrutura de capital, em especial com a teoria do trade-off estático que preconiza que quanto maior a alavancagem da empresa, maior a rentabilidade para os acionistas. O estudo não possui o objetivo de generalização dos resultados, ficando as conclusões restritas à amostra e ao período analisado. / The financing by negotiable securities has been gaining importance in the international scene and competing with traditional ways of financing such as the banking loans. However, there are not many scientific studies in Brazil that approach the financing of companies through debt securities, especially medium and long-run debts issued in international market, the eurobonds and euronotes. Therefore, the objective of this study is to analyze and describe the market of eurobonds and euronotes, its history, characteristics, tools and techniques, with special attention to the Brazilian securities. In order to do that, a descriptive-exploratory analysis and the establishment of relations between variables will be done through an ample revision of literature, presentation and exposition of historical market data, non-statistical analysis of emissions volumes and development. It is also the objective of this study to analyze empirically, through a descriptive and exploratory form, the profile of companies that issued bonds in the international market, and the utilization of bonds in the financing structure of Brazilian companies, supported by the theories of capital structure of the static trade-off and peking order. In order to do that, statistical analysis of panel data was used. Empirical results indicated that, in general, Brazilian companies that issue bonds in the international market show higher leverage, longer term, higher fixed assets / equity ratio, higher profitability derived from high level of sales, which also demonstrates the difference between the average size of companies with emission of bonds and others, confirming the verification of Valle (2001) that only large Brazilian companies issue in the eurobonds and foreign bonds markets. It was also verified that financial indicators and leverage level are related, in accordance with the theories of capital structure and especially with the theory of static trade-off which praises that the higher the company´s leverage, the higher the profitability for the shareholders. It is not an objective of the present study to generalize the results, being the conclusions restricted to the analyzed sample.
127

\"Avaliação biomecânica da união dente-implante com diferentes tipos de conectores, por meio do método dos elementos finitos\" / Biomechanical evaluation of implant-tooth union with different types of connectors through the finite element method

Betiol, Ederson Aureo Gonçalves 08 February 2007 (has links)
Este estudo apresenta uma análise, por meio do método não linear dos elementos finitos, de uma prótese parcial fixa de quatro elementos, tendo como pilares um dente natural, localizado na região do primeiro pré-molar inferior, e um implante osseointegrado, localizado na região do segundo molar inferior do mesmo hemiarco. Os modelos deste trabalho, foram criados a partir de radiografias periapicais da região posterior da mandíbula, foram digitalizadas e, posteriormente modificadas, dando origem aos modelos computacionais. Com auxílio do programa Ansys® simulou-se uma carga vertical de 175 N, distribuída ao longo dos retentores e pônticos desta prótese. Foram avaliadas três situações: Modelo 1: prótese fixa com conectores rígidos; Modelo 2: prótese fixa com um conector semi-rígido entre o primeiro pré-molar e o segundo pré-molar; Modelo 3: prótese fixa com um conector semi-rígido entre primeiro molar e segundo molar. Para simular os conectores semirígidos foram usados elementos de contato. A partir dos resultados obtidos, percebeu-se, em todos os modelos, que a região óssea que apresentou maior concentração de tensões foi a próximo da crista óssea mesial do implante, sendo os maiores níveis de tensões encontrados no Modelo 2 e os menores no modelo 3. Observou-se também, com relação ao implante, nos Modelos 1 e 3, altos níveis de tensões na região cervical-mesial, próximo da união retentor-pilar intermediário, já no Modelo 2 percebemos um grande aumento das tensões em toda região cervical. Constatou-se também, com relação aos conectores no Modelo 1, altos níveis de tensões entre os pônticos e entre o pôntico e o retentor sobre implante; no Modelo 2, os maiores níveis de tensões foram encontrados entre os molares e, no Modelo 3 os maiores níveis de tensões foram encontrados no conector semi-rígido. / The aim of this study was to analyze, through a non linear method of finite elements, a fixed partial denture of four elements, having natural teeth as an abutment located in the mandibular first pre-molar region and an osseointegrated implant located in the mandibular second molar region in the same hemi-arc, when a vertical load of 175N was applied and distributed over the retainer and pontic. Three situations were evaluated: Model 1: fixed denture with rigid connectors; Model 2: fixed denture with a semi-rigid connector between the first and second pre-molar; Model 3: fixed denture with a semi-rigid connector between first molar and second molar. From the results obtained from all models, the bone region that presented the highest stress concentration was close to the mesial region in the cortical bone of the implant. The highest stress levels were found in model 2 and the lowest in model 3. As regards the implant, in models 1 and 3, higher stress levels were also observed in the cervicalmesial region, close to the intermediate retainer abutment union. In model 2, a great increase of stress was observed in the entire cervical region. Moreover, with regard to the connectors, in model 1, there were high stress levels between the pontics and between the pontic and implant retainer; in model 2 the highest stress levels were found between the molars; and in model 3, the highest stress levels were found at the semi-rigid connector.
128

"Influência da esplintagem de restaurações protéticas fixas e do número de implantes na distribuição de tensões em mandíbula edentada posterior - análise em elementos finitos" / Influence of the splinting of fixed prosthetic restorations and the number of implants on stress distribution in posterior edentulous mandible – finite element analysis

Silva, Marcelo Gomes da 06 June 2005 (has links)
Em casos de edentulismo parcial, especialmente na ausência de três ou mais dentes posteriores contíguos, não há consenso sobre o número ideal de implantes a serem utilizados nem sobre a conveniência biomecânica de unir ou não as coroas protéticas. O presente estudo teve como finalidade analisar a influência da esplintagem de restaurações protéticas fixas e do número de implantes na distribuição das tensões de von Mises em modelos matemáticos bidimensionais obtidos pelo método de elementos finitos. A partir da imagem digitalizada de uma peça anatômica real, correspondente ao corte sagital da porção posterior esquerda de uma mandíbula, três modelos foram desenvolvidos com as seguintes configurações: (1) coroas protéticas isoladas sobre três implantes; (2) coroas protéticas esplintadas sobre três implantes; e (3) prótese parcial fixa sobre dois implantes, com um pôntico intermediário. Uma carga estática de 300N foi dividida, com igual magnitude, por 15 áreas de aplicação nas superfícies oclusais e angulada em 15º em relação ao longo eixo das restaurações. Os resultados mostraram que o modelo com coroas esplintadas sobre três implantes apresentou os menores valores de tensão, enquanto os maiores valores de tensão foram encontrados no modelo com coroas isoladas. O limite de proporcionalidade dos materiais e estruturas analisadas não foi alcançado nos três modelos, fato que não contra-indicou nenhuma das configurações estudadas. Entretanto, os resultados sugeriram que o planejamento do tratamento deve ser adequado a condições anatômicas, oclusais e biomecânicas específicas. / In cases of partial edentulism, specially in the absence of three or more contiguous posterior teeth, there is not a consensus about the ideal number of implants nor the biomechanical convenience of splinting or not prosthetic crowns. The aim of the present study was to analyze the influence of the splinting of fixed prosthetic restorations and the number of implants on von Mises stress distribution within mathematical two-dimensional models obtained from finite element method. From the digitalized image of a real anatomical piece, corresponding to the sagital slice of the left posterior portion of a mandible, three models were constructed in the following configurations: (1) non-splinted prosthetic crowns on three implants; (2) splinted prosthetic crowns on three implants; and (3) fixed partial denture on two implants, with an intermediate pontic. A 300N static load was divided, in equal magnitude, by 15 application areas on occlusal surfaces and angled in 15º in relation to the long axis of the restorations. The results showed that the model with splinted crowns on three implants presented the lowest stress values, whereas the highest stress values were found in the model with non-splinted crowns. The proportional limit of the analyzed materials and structures was not reached in the three models, fact that did not contraindicate any studied configuration. However, the results suggested that treatment planning may be adequate to anatomical, occlusal and biomechanical specific conditions.
129

Análise pelo método dos elementos finitos da distribuição de tensões em componentes protéticos posicionados em implantes com conexão cone morse na região anterior da maxila / Analysis by the finite element method of the stress distribution in prosthetic components placed in implants with morse cone connection in the anterior maxilla

López, Camilo Andrés Villabona 02 August 2012 (has links)
O objetivo desse estudo foi avaliar, por meio do método tridimensional dos elementos finitos, a distribuição de tensões na interface osso/implante e implante/pilar em implantes com conexão cone morse, posicionados na região anterior da maxila. A partir de uma reconstrução virtual óssea proveniente de uma tomografia computadorizada, foi simulada uma prótese cantilever (11-21) utilizando componente protético com pescoço de 2,5 mm de altura posicionado sobre implantes de 3,75 mm e 4,0 mm de diâmetro e 8,5 mm e 10 mm de comprimento; e prótese parcial fixa convencional (12-22) com componente protético com pescoço de 1,5 mm posicionado em implantes com 3,75 mm e 3,3 mm de diâmetro e 8,5 mm e 10 mm de comprimento. O ensaio realizado com aplicação de carga de 178 N e inclinação de 45° em relação ao longo eixo do implante na superfície palatina das próteses. A tensão de pico Equivalente Von Mises para ambos os casos clínicos foram localizados em áreas do pescoço dos componentes protéticos, plataforma e pescoço dos implantes e região óssea periimplantar. Na região dos incisivos centrais, o pico mais elevado de tensão Von mises correspondeu ao implante de 3,75 mm x 8,5 mm (370,413 MPa), e o menor ao implante de 4,0 mm x 8,5 mm valor (367, 475 MPa). No osso periimplantar a tensão de pico variou de 53,846 MPa para implante 3,75 mm x 8,5 mm à 47,284 MPa para implante 4,0 mm x 10 mm. Para implantes posicionados na região dos incisivos laterais, o valor mais elevado correspondeu ao implante de 3,3 mm x 8,5 mm (832, 911 MPa), e o menor valor ao implante de 3,75 mm x 8,5 mm (433, 666 MPa). No osso periimplantar a tensão de pico variou de 64,433 MPa, para implante 3,3 mm x 8,5 mm, à 50,277 MPa para implante 3,75 mm x 10 mm. Conclui-se que os valores e áreas de pico de tensão nos componentes protéticos posicionados em implantes com os diferentes comprimentos (8,5 mm e 10 mm) e diâmetros (3,75 mm e 4,0 mm), na região dos incisivos centrais, foram semelhantes. Implantes com mesmo diâmetro, posicionados na região dos incisivos laterais apresentaram valores e áreas de tensão semelhantes no pilar protético e osso periimplantar, independente do comprimento. Implantes com 3,3 mm de diâmetro apresentaram o dobro dos valores que implantes com 3,75 mm. / The aim of this study was to evaluate through the three-dimensional method of the finite elements the stress distribution in the bone / implant interface and implant / abutment on implants with morse cone connection, placed in the anterior maxilla. From a virtual reconstruction of bone from a CT scan, cantilever prosthesis (11-21) was simulated using prosthetic component with neck height of 2.5 mm placed in the implant with 3.75 and 4.0 mm diameter and 8.5 and 10 mm length; and conventional fixed partial denture (12-22) with prosthetic component with neck height of 1.5 mm placed in implants with 3.75 and 3.3mm of diameter and 8.5 mm and 10 mm length. The test performed with application of load of 178 N and inclination of 45 ° to the long axis of the implant in the palatal surface of the prosthesis. The peak stress concentration Equivalent Von Mises for both clinical cases were found in areas of the neck of the prosthetic components, platform and neck implants and peri-implant bone area. In the central incisors region, the highest value stressVon mises corresponded to 8.5 x 3.75 mm implant (370.413 MPa), and the lowest value to 4.0 x 8.5 mm implant (367 , 475 MPa). At the peri-implant bone the stress ranged from 53.846 MPa for 8.5 mm x 3.75 mm implant to 47,284 MPa for 4.0 mm x 10 mm implant. For implants placed in the lateral incisors region, the highest value corresponded to 3.3 x 8.5 mm implant (832 , 911 MPa ), and the lowest value to 3.75 mm x 8.5 mm implant (433, 666 MPa ). At the peri-implant bone the highest value stressVon mises ranged from 64.433 MPa for 3.3 mm x 8.5 mm implant, to 50,277 MPa for 3.75 x 10 mm implant. It follows that the values and peak areas of stress on the prosthetic components placed on implants with different lengths ( 8.5 to 10 mm) and diameter (3.75 and 4.0 mm), in the central incisors area, were similar. Implants with the same diameter, placed in the lateral incisors area showed values and areas of tension similar on the abutment and peri-implant bone area, regardless of the length. Implants with 3.3 mm diameter were twice the values that 3.75 mm implants.
130

Análise fotoelástica das tensões ao redor das estruturas peri-implantares, suportes de próteses fixas com revestimento em cerâmica / Photoelastic analysis of tensions around peri-implant structures, fixed prosthesis support with ceramic coating

Gomes, Maria Helena Garcia 29 May 2013 (has links)
Esta pesquisa teve como objetivo avaliar, o comportamento das tensões na estrutura de suporte peri-implantar, decorrentes da pressão atuante sobre uma prótese fixa revestida em cerâmica, por meio do método fotoelástico. Foram confeccionadas três mandíbulas em resina fotoelástica, cada uma contendo 5 implantes hexágono externo de 3,75mm de diâmetro, com comprimentos variáveis denominadas MOD10 (implantes com 10mm); MOD13 (implantes com 13mm); MOD15 (implantes com 15mm), localizados na região interforaminal, paralelos entre si. Foi construída uma estrutura de prótese fixa em cobalto/cromo, com extensão distal bilateral (cantilever) de 15mm de comprimento, revestida por cerâmica, aparafusada sobre pilares micro unit com cinta de 1,0mm. Foi realizado um correto ajuste oclusal, em máxima intercuspidação, entre os dentes antagonistas. Os modelos foram submetidos à pressão de 1,0 e 3,0 bars, de forma a incidir axialmente sobre os implantes. O comportamento foi avaliado por visualização direta, em tempo real, e pelas imagens realizadas por meio dos registros fotográficos. Os resultados mostraram que, quanto maior o comprimento do implante, maior a propagação de tensão ao longo do corpo do implante e nos seus ápices; os implantes localizados mais distalmente, próximos ao cantilever, apresentaram maiores tensões em relação aos demais; o aumento do comprimento do implante aumentou a propagação de tensão ao longo da estrutura mandibular, como o corpo e ramo ascendente da mandíbula. Concluiu-se que: 1. Quanto maior o comprimento do implante suporte de prótese fixa, revestida em cerâmica, as tensões são mais distribuídas ao longo do seu corpo e ápice, propagando-se pelas estruturas mandibulares. 2. Os implantes próximos ao cantilever são os mais sobrecarregados, apresentando as maiores tensões. / The purpose of this research was to evaluate, using the photoelastic method, the behavior of tensions on peri-implant-supported structure deriving from pressure applied to a ceramic-coated fixed prosthesis . Three photoelastic-resin mandibles were built, each of them containing five 3.75-mm external hexagon implants with variable lengths and denominated MOD10 (implants with 10mm), MOD13 (implants with 13mm), MOD15 (implants with 15mm), located in parallel with each other in the interforaminal region. A fixed cobalt/chrome prosthesis structure was built with 15mm-bilateral-distal-length (cantilever), coated in ceramic, and screwed onto microunit pillars with a 1.0mm belt. A proper oclusal adjustment was performed at maximum intercuspation between antagonistic teeth. Models were submitted to pressures of 1.0 and 3.0 bars applied on implants at axial ends. Their behavior was evaluated by direct real-time visualization and by photographic images. Results showed that the greater the implant length, the greater the propagation of tension along implant length and on its apices; implants distally located, next to the cantilever, presented greater tensions in relation to others; as implant length increase, propagation of tension along the mandibular structure, such as the mandible body and ascending arm, also increase. Conclusion was 1. The longer the fixed-prosthesis-supported implant, coated in ceramic, the more tensions are distributed along its body and apex, propagating along mandibular structures. 2. Implants closer to the cantilever are those supporting the highest load and presenting the highest tensions.

Page generated in 0.0573 seconds