• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 243
  • 11
  • 11
  • 11
  • 11
  • 10
  • 6
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 255
  • 130
  • 110
  • 98
  • 68
  • 58
  • 58
  • 57
  • 49
  • 44
  • 38
  • 29
  • 29
  • 29
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Análise da volatilidade dos mercados de renda fixa e renda variável de países emergentes e desenvolvidos no período de 2000 a 2011 / Analysis of volatility of fixed income market and stock market of emerging and developed countries in the period 2000-2011

Rossetti, Nara 15 August 2013 (has links)
O presente trabalho analisou as volatilidades dos mercados de renda fixa e variável de onze países, sendo eles: Brasil, Rússia, Índia, China, África do Sul (neste país apenas renda fixa), Argentina, Chile, México, Estados Unidos, Alemanha e Japão no período de janeiro de 2000 a dezembro de 2011. Os indicadores utilizados para representar cada mercado foram os índices dos mercados de ações e as taxas de juros interbancárias. Para tanto, o estudo se utilizou de modelos de heterocedasticidade condicional auto-regressiva: ARCH, GARCH, EGARCH, TGARCH e PGARCH, verificando quais destes processos eram mais eficientes para modelagem da volatilidade dos mercados dos países da amostra. Esta pesquisa também verificou qual dos modelos (ARIMA ou modelos GARCH e suas extensões) conseguiria prever melhor as séries de tempo analisadas. Além disso, por meio dos índices de correlação, covariância e causalidade Granger, foram comparados os retornos e a volatilidade do mercado de ações entre os países BRIC, entre os países latinos americanos e entre os países desenvolvidos e o Brasil. Os resultados sugerem que a volatilidade, tanto do mercado de renda fixa quanto do mercado de renda variável, é mais bem modelada por processos GARCH assimétricos (EGARCH e TGARCH), demonstrando efeitos de alavancagem nas séries estudadas. Quanto aos modelos de previsão, os modelos ARIMA, também para os dois mercados, mostrou-se mais eficiente que os modelos GARCH e suas extensões. Além disso, as volatilidades dos mercados de ações entre os países analisados parecem ser mais correlacionadas e possuir maior causalidade Granger do que os retornos destes países. Entre os dois mercados, renda fixa e variável dentro de cada país, as correlações dos retornos e da volatilidade são muito baixas, em algumas vezes negativa, e há pouca relação de causalidade Granger. / This study analyzed the volatility of fixed income and stocks markets for eleven countries, namely: Brazil, Russia, India, China, South Africa (just fixed income), Argentina, Chile, Mexico, United States, Germany and Japan from January 2000 to December 2011, using interbank interest rate as a fixed income market indicator and stock index to each country, as a stock market indicator. Therefore, the study used models of autoregressive conditional heteroscedasticity: ARCH, GARCH, EGARCH, TGARCH e PGARCH to verify which of these processes were more effective for in volatility modeling in each country. This research also found that the models (ARIMA or GARCH models and their extensions) could be used as the best forecast models. Moreover, by means of correlation coefficients, covariance and Granger causality, were used to compare the returns and volatility of the stock market among the BRIC countries, among the Latin American countries and between developed countries and Brazil. The results suggest that the volatility of both the fixed income market as the stock market is best modeled by processes asymmetric GARCH (EGARCH and TGARCH) demonstrating leverage effects in the time series. Regarding prediction ARIMA models was more efficient for both markets than GARCH models and extensions. In addition, the volatility of stock markets across countries analyzed seem to be more correlated and have higher Granger causality than returns these countries. Between the two markets, for each country, the correlations of returns and volatility are very low, if not positive, and there is low Granger causality.
132

\"Estudo longitudinal da força de mordida em pacientes portadores de próteses parciais fixas sobre implantes osseointegrados: comparação entre áreas dentadas e implantadas\" / Bite force longitudinal study on patients wearing implant-supported partial prothesis

Fileni, Renan Hollanda 22 March 2007 (has links)
A proposta deste estudo foi analisar o desenvolvimento da força máxima de mordida em um grupo de pacientes que recebeu próteses parciais fixas sobre implantes (PPFSI) nas regiões de molares, pré-molares até caninos e incisivos antagonizando com dentes naturais e comparar os resultados obtidos com as áreas dentadas do mesmo grupo de pacientes, durante um período de 64 meses (5,3 anos). As forças de mordida foram medidas em cinco regiões da boca: molares em ambos os lados, pré-molares ou caninos em ambos os lados e incisivos; nas áreas de próteses sobre implantes e também nas áreas de dentes naturais. Para tanto, foi usado um transdutor medidor de força de mordida, que tem como princípio de funcionamento uma célula de força colada a um garfo de mordida, amplamente usado na literatura e sempre operado pelo pesquisador. As medições foram feitas imediatamente após a instalação das próteses, 3, 30 e 64 meses depois. Comparando o desenvolvimento das forças de mordida entre as áreas implantadas e de dentes naturais encontra-se já no primeiro controle, após 3 meses de instalação, um aumento das forças de mordida nas próteses sobre implantes instaladas na região de molares que supera as forças desenvolvidas por dentes naturais na mesma região. Para as próteses instaladas na área de incisivos, ao contrário, não foi registrado aumento estatístico destas forças, havendo uma tendência em permanecerem menores quando comparadas às forças desenvolvidas nas mesmas regiões por dentes naturais. Na região de pré-molares ou caninos não houve aumento estatístico de força nas PPFSI. Quando analisadas as áreas dentadas dos pacientes, não houve mudança estatística de força de mordida em nenhuma das regiões durante todo o experimento. / This study proposal was to analyse the changes on the maximal bite force on a patients sample who had implant-supported partial fixed prosthesis (FPP) installed and the results were compared to the ones obtained from the dentate areas on the same sample. Sixteen patients were followed for sixty-four months (5.3 years) and the bite forces were measured on the mouth regions which the prosthesis were installed (molars and premolars up to canines and incisors regions). This measured occurred on five regions of the mouth: both side molars, pre-molars or canines and incisives; either on the places it had a implant as well as on the natural teeth area. In order to do that, it was used as a measuring device, a largely used apparatus which consisted of a biting fork provided with a strain gauge. The bite forces recordings were made at the time of prosthesis installation, after 3, 30 and 64 months thereafter. It was found a bite force increase in the initial period of 3 months after the prosthesis installation in the area of FPP in the molar regions. In this period the bite forces became higher than in dentate situation in the same region and it manteined on this level until the final of the experiment. Comparing the bite straight development between the implanted areas and the natural teeth areas, we found a bite force increased on the prostheses installed over the molars region that overcome the straight development for natural teeth on the same area. On the other hand, for the prostheses installed on the incisive areas, we had not found a statistical straight increased. Actually, it was a tendency to keep smaller than the straight developed on the same regions by natural teeth. On premolars regions or canines, there was not a straight statistical increased on PPFSI. When we analyze the patients? teeth areas, there was not a statistical bite increase on any of the premolars or canines regions during the entire experiment.
133

Avalia??o da pr?-carga e torque de remo??o de tr?s parafusos de pilares para pr?teses unit?rias implantossuportadas ap?s ciclagem mec?nica

Silva, Fabr?cio Dorigon da 21 January 2010 (has links)
Made available in DSpace on 2015-04-14T13:29:36Z (GMT). No. of bitstreams: 1 422731.pdf: 4008244 bytes, checksum: 02ec9a1844e8d5ae7be399b6caabc500 (MD5) Previous issue date: 2010-01-21 / Este estudo in vitro teve como objetivo comparar os valores de pr?-carga e torque de remo??o de tr?s tipos de parafusos de fixa??o de pilares para pr?teses unit?rias submetidos ao teste de ciclagem mec?nica. Foram utilizados 10 implantes hex?gono externo (Conex?o?, Sistemas de Pr?tese Ltda., S?o Paulo, Brasil) com 4,0mm de di?metro e 15,0mm de comprimento, nos quais foram cimentadas 30 coroas met?licas sobre abutments Cera One?, fixados com seus respectivos parafusos de ouro, tit?nio e tit?nio com tratamento de superf?cie (Torq-Tite?). Os parafusos foram inseridos e registrou-se a pr?-carga inicial. Ap?s cimenta??o das coroas, as amostras foram posicionadas na cicladora mec?nica e submetidas a 400 mil ciclos com freq??ncia de 1 ciclo/segundo e carga de 100N. Ap?s o teste, foi avaliado o valor de pr?-carga produzido com a utiliza??o da c?lula medidora de carga e extens?metros. Para mensura??o dos torques de aperto e remo??o, utilizou-se dispositivo eletr?nico de controle de torque. Os parafusos de ouro apresentaram os maiores valores de pr?-carga (pr?-ciclagem 341,00?78,53 N; p?s-ciclagem 284,60?72,81 N) em rela??o aos parafusos de tit?nio (pr?-ciclagem 235,00?27,39 N; p?s-ciclagem 196,00?29,66 N) e tratado (pr?-ciclagem 284,00?70,92 N; p?s-ciclagem 195,00?69,28 N). Para os valores de torque de remo??o, os maiores registros foram encontrados para o grupo tit?nio (21,00 ? 0,79 Ncm), seguido do grupo ouro (18,06?1,94 Ncm) e tratado (16,64?1,38 Ncm). Ap?s an?lise estat?stica, ANOVA (p<0,10) e T-Student (p<0,05), foram encontradas diferen?as significativas entre os tr?s grupos, para pr?-carga, pr? e p?s-ciclagem e torque de remo??o. Devido aos maiores valores de pr?-carga obtidos nos resultados do estudo, sugere-se que os parafusos de ouro sejam os mais indicados para obten??o de estabilidade da junta pilar-implante.
134

Avalia??o histol?gica na interface ?ssea ap?s a coloca??o de miniplacas e parafusos com diferentes composi??es met?licas : estudo in vivo

Avelar, Rafael Linard 15 December 2010 (has links)
Made available in DSpace on 2015-04-14T13:29:49Z (GMT). No. of bitstreams: 1 428173.pdf: 3267525 bytes, checksum: 111e79e4715696d409dab4a83d48e6c0 (MD5) Previous issue date: 2010-12-15 / OBJETIVO: Avaliar as altera??es histol?gicas ?sseas superficiais ap?s a inser??o de miniplacas e parafusos com diferentes composi??es met?licas. MATERIAL E METODOS: Dezoito ratos, da linhagem Wistar, foram utilizados. Uma miniplaca e dois parafusos foram inseridos na superf?cie externa do f?mur direito de cada animal. Todos os parafusos foram de 5,0 mm de comprimento e foram inseridos at? as pontas serem projetadas pelo lado endosteal. Os animais foram divididos em tr?s grupos com seis animais cada. Nos primeiros seis animais foram colocados uma placa e dois parafusos de tit?nio, em outros seis animais foram colocados uma placa de tit?nio e dois parafusos de a?o inoxid?vel, e nos animais restantes foram colocados placa e parafuso revestido com Diamond-Like Carbon (DLC). Ap?s 30 dias da realiza??o do procedimento cir?rgico, as miniplacas e os parafusos foram retirados e foram feitas avalia??es histol?gicas na interface placa parafuso no defeito ?sseo, em uma extens?o de 0,5 cm2. RESULTADOS: Na avalia??o histol?gica observou-se um maior processo inflamat?rio no grupo com diferentes composi??es met?licas (Grupo tit?nio-a?o)(p=0,204), como tamb?m uma maior presen?a de lacunas de Howship que indicam uma poss?vel oste?lise em decorr?ncia de um ?nicio de corros?o galv?nica entre o tit?nio e o a?o inoxid?vel (p=0.002). CONCLUS?ES: Os resultados deste estudo indicam que, quando usamos diferentes materiais com diferentes composi??es met?licas, os componentes de implantes de a?o inoxid?vel quando em associa??o com o tit?nio t?m uma maior suscetibilidade ? provocar oste?lise do que quando se utilizam os mesmos componentes como materiais de fixa??o.
135

Avalia??o histol?gica tardia da superf?cie ?ssea ap?s a fixa??o de miniplacas e parafusos com diferentes ligas met?licas : estudo in vivo em ratos Wistar

Dolzan, Andr? do Nascimento 29 August 2013 (has links)
Made available in DSpace on 2015-04-14T13:30:27Z (GMT). No. of bitstreams: 1 451617.pdf: 638194 bytes, checksum: f2470bb81322e6a32a3d10b371e1182b (MD5) Previous issue date: 2013-08-29 / Objective: To evaluate the histological changes of bone surface after insertion of mini-plates and screws in the bone surface. Material and methods: Eighteen rats of Wistar strain were used, a plate and two screws were inserted in the external cortex of the femur of each animal. The animals were divided into three groups of six animals each, after thirty days of completion of the procedure the implanted material was removed cirurgiacamente after euthanasia of animals, and the bone surface ready to be removed and analyzed histologically. Results: Histological evaluation after marking immunohistochemistry, Group 3, with different materials, showed an increased inflammatory infiltrate in uperf?cie area analyzed, which indicated a possible area of osteolysis. Groups 1 and 2 showed no statistically significant differences showing an increase of the standard normal reparative inflammation. Conclusions: The results of study indicated that the use of different materials increase the chance of encountering large areas of osteolysis in the bone surface in contact with these materials. / Objetivo: Avaliar as altera??es histol?gicas da superf?cie ?ssea ap?s a inser??o de miniplacas e parafusos na superf?cie ?ssea. Materiais e m?todos: Dezoito ratos, da linhagem Wistar, foram utilizados; Uma placa e dois parafusos de fixa??o foram inseridos na cortical externa do f?mur de cada animal. Os animais foram divididos em tr?s grupos de seis animais cada, ap?s trinta dias da realiza??o do procedimento o material implantado foi removido cirurgicamente ap?s a eutan?sia dos animais, e a superf?cie ?ssea removida e preparada para ser analisadas histologicamente. Resultados: Na avalia??o histol?gica, ap?s a marca??o imunohistoqu?mica, O grupo 3, com diferentes materiais, apresentou um aumento do infiltrado inflamat?rio na superf?cie de ?rea analisada, que indicou uma poss?vel oste?lise da regi?o. Os grupos 1 e 2 n?o apresentaram diferen?as estat?sticas significantes que demonstrassem um aumento do padr?o normal de inflama??o reparativa. Conclus?es: Os resultados do trabalho indicam que o uso de diferentes materiais aumentam a possibilidade de ocorrer ?reas de oste?lise na superf?cie ?ssea em contato com esses materiais.
136

Influência do material e técnica de obtenção da infraestrutura na distribuição de tensão de próteses parciais fixas com cantilever / Influence of material and infrastructure obtaining techniques on the stress distribution of cantilever fixed partial dentures

Tonin, Bruna Santos Honório 23 January 2017 (has links)
A passividade da prótese parcial fixa (PPF) sobre implante e a distribuição de tensões ao osso pela infraestrutura, contribuem não só com a osseointegração como também para a sua manutenção. A análise de tensões por fotoelasticidade permite visualizar as magnitudes de tensões e deformações em um modelo confeccionado em resina fotoelástica que possui padrão de concentração e distribuição de tensões semelhantes ao tecido ósseo. Assim, este estudo teve como objetivos comparar a distribuição de tensões de PPFs associadas à cantilever com diferentes materiais de infraestrutura (Co-Cr e Zircônia [Zr]) e métodos de obtenção (CAD/CAM e fundição convencional [monobloco, soldagem a laser e soldagem com TIG]), quando submetidos a diferentes carregamentos oclusais (puntiforme e oclusal distribuído). A partir de um modelo mestre, foram confeccionados 3 modelos fotoelásticos simulando extremidade livre mandibular,com o dente 44 em resina e 2 implantes substituindo os dentes 45 e 46. Os grupos deste estudo incluíram PPFs com infraestruturas obtidas por meio de fundição convencional em monobloco (G1), seccionadas e soldadas a laser (G2) e com TIG (G3) e obtidas por meio do sistema CAD/CAM em Co-Cr (G4) e Zr (G5). As PPFs foram parafusadas sobre os mini pilares e submetidas a carregamento oclusal puntiforme e distribuído (150 N) para avaliação qualitativa das franjas e quantitativa em seis diferentes pontos: apical (P1) e distal (P2) do dente 44, apical (P3) e distal (P4) do implante substituindo o dente 45, apical (P5) e distal (P6) do implante substituindo o dente 46. A análise fotoelástica mostrou maior concentração de tensões na PPF com infraestrutura em monobloco (G1) e menor concentração nas próteses obtidas pelo método CAD/CAM (G4 e G5). Quando submetidos ao carregamento oclusal distribuído, a PPF com infraestrutura em Zr (G5) apresentou um aumento considerável na concentração de tensões, seguida por monobloco (G1) e as que foram soldadas a laser (G2) e TIG (G3). No carregamento pontual sobre o cantilever, a infraestrutura em Co-Cr soldada a TIG (G3) mostrou a maior concentração de tensões. Dentro das limitações deste estudo, concluiu-se que PPFs com infraestruturas obtidas por meio do sistema CAD/CAM foram associadas com menor concentração de tensões e que a secção de infraestruturas metálicas para posterior soldagem pode também ser uma alternativa viável, de acordo com a distribuição de tensões peri-implantes. / The passivity of fixed partial denture (FPD) on implant and the stress distribution to the bone by the infrastructure, contribute not only to osseointegration but also to its maintenance. The stress analysis by photoelasticity allows visualizing the stresses and deformations magnitudes in a model fabricated in photoelastic resin that has a concentration pattern and stress distribution similar to the bone tissue. The aim of this study was to compare the stress distribution of cantilever FDPs with different infrastructure materials (Co-Cr and Zirconia [Zr]) and methods of manufacture (CAD/CAM and conventional casting [one piece, laser welding and welding with TIG]), when submitted to different occlusal loads (punctiform and distributed occlusal). From a master model, 3 photoelastic models were fabricated to simulate the mandibular free end, with the tooth 44 in resin and 2 implants replacing the teeth 45 and 46. The groups of this study included FPDs with infrastructures obtained by conventional casting in one piece (G1), sectioned and laser welded (G2) and TIG (G3) and obtained by the CAD/CAM system in Co-Cr (G4) and Zr (G5). The FDPs were screwed onto the abutments and subjected to punctate and distributed occlusal loading (150 N) for qualitative evaluation of the fringes and quantitative at six different points: apical (P1) and distal (P2) of the tooth 44, apical (P3) and distal (P4) of the implant replacing the tooth 45, apical (P5) and distal (P6) of the implant replacing the tooth 46. The photoelastic analysis showed a higher concentration of stresses in the FPD with one piece infrastructure (G1) and a lower concentration in the prosthesis obtained by CAD/CAM method (G4 and G5). When submitted to distributed occlusal loading, the FPD with Zr infrastructure (G5) showed a considerable increase in stress concentration, followed by one piece (G1) and those that were laser (G2) and TIG (G3) welded. In the cantilever load, the TIG welded Co-Cr infrastructure (G3) showed the highest stress concentration. Within the limitations of this study, it was concluded that FPDs with infrastructures obtained by the CAD/CAM system were associated with lower stress concentrations and that the section of metal infrastructures for later welding may also be a viable alternative, according to the peri-implant stress distribution.
137

Formação de preço de debêntures no Brasil / Pricing of debentures in Brazil

Paiva, Eduardo Vieira dos Santos 27 April 2011 (has links)
O objetivo da tese foi analisar a influência do rating, provido por agências independentes na formação dos preços de emissão de debêntures. A base de dados contou com 354 séries de debêntures não conversíveis, emitidas por empresas não financeiras, entre janeiro de 2000 e junho de 2010, em mercado primário público. A metodologia baseia-se no modelo fatorial de precificação aplicado a uma estrutura de dados pooled cross-section. Os modelos desenvolvidos ao longo do trabalho apontaram a relevância do rating na explicação do spread de emissão primária de debêntures no Brasil. Isoladamente, no entanto, explica cerca de 10% da variabilidade do spread. O estudo demonstrou serem significativas variáveis de crédito, maturidade, relação entre o volume emitido e o estoque de debêntures do mercado, a evolução do PIB e a alteração futura de rating (direção e a magnitude). Constatou-se também que emissões em percentual do DI tendem a ter menor spread que aquelas remuneradas por inflação mais taxa. Não se pode afirmar que o mercado diferencie, por meio do preço, a origem das agências ou as emissões com mais de um rating. As variáveis idiossincráticas da firma, na forma de índices econômico-financeiros extraídos de demonstrações financeiras publicadas, explicam diferenças de rating. Finalmente, constatou-se a utilidade da variável de escala linear de rating nos modelos de regressão desenvolvidos. / The overall objective of this dissertation was to analyze the influence of the rating provided by independent agencies in the spread of corporate bonds. The database was comprised of 354 series of non-convertible debentures issued by non-financial companies between January 2000 and June 2010 in public primary market. The study approach is based on the pricing factor model applied to a pooled cross-section data structure. The developed models suggested that the rating is significant in explaining the spread of primary issuance of debentures in Brazil. However, the rating explains no more than 10% of the spread variability. The study revealed that other factors were also significant during the analyzed period along with the credit variables: maturity, the ratio between the volume issued and total market outstanding of debentures, GDP growth, and future rating changes. It was also noted that series linked daily floating rates tend to have lower spread than those linked to inflation. When price is taken into account, the market does not seem to differentiate local agencies from international ones, or series with two or more ratings. Financial ratios obtained from financial statements, do explain the differences in rating. Finally, other important findings indicate the usefulness of the rating variable based in linear scale in the regression models developed in this work
138

Concepções de capacidade e aprendizagem de uma habilidade motora esportiva em adolescentes / Concepts of ability and learning of a skill motor sports in adolescents

Silva, Alessandra Reis da 08 July 2016 (has links)
Submitted by Anelise Milech (anelisemilech@gmail.com) on 2017-11-07T15:36:41Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Alessandra Reis da Silva.pdf: 1066738 bytes, checksum: 5c1c735a29e122a3a93a12a4bba8f8fc (MD5) / Approved for entry into archive by Aline Batista (alinehb.ufpel@gmail.com) on 2018-01-02T13:32:48Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Alessandra Reis da Silva.pdf: 1066738 bytes, checksum: 5c1c735a29e122a3a93a12a4bba8f8fc (MD5) / Approved for entry into archive by Aline Batista (alinehb.ufpel@gmail.com) on 2018-01-02T13:34:01Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Alessandra Reis da Silva.pdf: 1066738 bytes, checksum: 5c1c735a29e122a3a93a12a4bba8f8fc (MD5) / Made available in DSpace on 2018-01-02T13:34:09Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Alessandra Reis da Silva.pdf: 1066738 bytes, checksum: 5c1c735a29e122a3a93a12a4bba8f8fc (MD5) Previous issue date: 2016-07-08 / O objetivo da presente pesquisa foi verificar os efeitos das concepções de capacidade no desempenho e aprendizagem de uma habilidade motora do futsal em adolescentes. O estudo foi composto por três grupos experimentais com fases de pré teste, prática, retenção e transferência. Participaram do experimento 45 adolescentes, de ambos os sexos, pareados e randomizados em três grupos: concepções de capacidade fixa (CCF), concepções de capacidade maleável (CCM) e controle (C). Para o grupo CCF as instruções induziam a concepção de que a capacidade para driblar é inata, nasce com os indivíduos, enquanto para o grupo CCM as instruções induziam a concepção de que a habilidade pode ser aprendida. Para o grupo controle não era dada nenhuma indução de concepções de capacidade. A tarefa consistia em ir e voltar conduzindo uma bola de futsal com o pé não dominante, no menor tempo possível, contornando em ziguezague cones posicionados em linha reta, numa distância de um metro um do outro. A fase de prática consistiu em 15 tentativas, enquanto as fases de retenção e transferência, de 5 tentativas cada. Questionários de auto eficácia, afetos positivo e negativo e motiviação foram aplicados após o pré-teste, após a prática, antes da retenção e após a transferência. Os resultados mostraram que não houveram diferenças no desempenho e aprendizagem da tarefa, assim como nos questionários, entre os grupos. Concluindo, tais achados indicam que as instruções utilizadas, induzindo diferentes concepções de capacidade, não afetaram a aprendizagem da habilidade motora do drible do futebol em adolescentes. / The objective it was to check the effects of different capacity concepts on performance and learning of futsal motor skills in teenagers. The study consists of three experimental groups with the following phases each: pretest, practice, retention and transfer. It was 45 male and female teenagers participated in the experiment, randomly grouped into three diferente groups: fixed capacity conceptions (FCC), malleable capacity conceptions (MCC) and control (C). For the FCC group the instructions prompt to the idea that the ability to dribble is innate, born with individuals, while for the MCC group the instructions prompt to the idea that the skill can be learned. The control group was given no induction ability concepts. The task was to get to and conducting a futsal ball with the non-dominant foot in the shortest time possible, bypassing zigzag cones positioned in a straight line at a distance of one meter from each other. There 15 trials on the practice phase and 5 trials on the retention and transfer phases. Self-efficacy, positive and negative affects and motivational questionnaires were applied after the pretest, practice and transfer phases as well as before the withholding phase. The results showed that there were no differences in the performance and learning tasks. That was also seen in the questionnaires results from the different groups. Concluding the results indicate that the instructions used, prompting to different conceptions of ability, did not affect the learning of the motor skills necessary for dribbling in soccer in teenagers.
139

Efeito de uma malha de nylon contendo sílica como reforço em próteses parciais fixas em resina composta indireta /

Firmino, Aline Silva. January 2017 (has links)
Orientador: Tarcisio José de Arruda Paes Junior / Banca: Lafayette Nogueira Junior / Banca: Sâmia Carolina Mota Cavalcanti Sacorague / Resumo: O presente estudo teve como objetivo avaliar as características mecânicas de próteses parciais fixas adesivas, confeccionadas em resina composta de uso indireto, reforçadas por uma malha de nylon. Para a confecção da matriz dos espécimes e estudo das tensões nas estruturas, foi realizada análise qualitativa pregressa análise de elementos finitos (FEA). A pesquisa in vitro simula uma prótese parcial fixa de três elementos com inserção entre os primeiros pré-molares e os primeiros molares superiores (n = 60; 10 por grupo). Três dos seis grupos passaram por ciclagem mecânica. Os grupos experimentais foram: G1-prótese fixa convencional; G2 - prótese convencional ciclada; G3 - prótese com reforço da malha posicionada na vertical; G4 - Prótese com reforço da malha posicionada na vertical ciclada; G5 - Prótese com reforço da malha posicionada na horizontal; G6 - Prótese com reforço da malha posicionada na horizontal ciclada.Todos os grupos passaram por ensaio de carga máxima a fratura (EMIC). Os resultados não apresentaram diferença estatística entre os grupos. Concluiu-se que a utilização da malha nylon proporcionou estabilidade, mesmo após a fratura da peça, pois as partes não se separam, além disso, os resultados obtidos in vitro puderam validar os dados in sílico / Abstract: The present study aimed to evaluate the mechanical characteristics of adhesive fixed partial dentures, made from composite resin of indirect use, reinforced by a nylon mesh. A finite element analysis (FEA) was used to compile the specimen matrix and to study the stresses in the structures. In vitro research, simulated a fixed partial denture of three elements with insertion between the first premolars and the major maxillary molars (n = 60; 10 per group). Three of the six groups underwent mechanical cycling. The experimental groups were: G1 - conventional fixed prosthesis; G2 - conventional cyst prosthesis; G3 - prosthesis with reinforcement of the mesh positioned vertically; G4 - Prosthesis with reinforcement of the mesh positioned in the cycled vertical; G5 - Prosthetics with mesh reflux positioned horizontally; G6 - Prosthetics with mesh reinforcement positioned horizontally cycled. All groups underwent maximum fracture loading test (EMIC). The results do not present a statistic between the groups. It was concluded that the use of the nylon mesh provided stability, even after fracture of the part, as parts do not separate, besides, the results obtained in vitro could validate the data in silica / Mestre
140

Análise das tensões geradas por implantes curtos e convencionais reabilitados com próteses fixas unidas e isoladas, por meio do método de correlação de imagem digital / Analysis of the stresses generated by short and conventional implants rehabilitated with splinted and non-splinted fixed prosthesis by digital image correlation method

Raniel Fernandes Peixoto 06 December 2013 (has links)
Nos casos de perda óssea vertical severa, principalmente em áreas posteriores da mandíbula, o uso de implantes curtos associado a próteses fixas metaloplásticas esplintadas pode ser uma alternativa às cirurgias de enxerto ósseo e a melhor transmissão de tensões ao osso adjacente, respectivamente. Dentre os métodos que avaliam a distribuição de tensões em torno dos implantes, a Correlação de Imagem Digital (CID) leva vantagens no que diz respeito à possibilidade de avaliar a distribuição das tensões de forma contínua por meio de imagens obtidas ao longo do tempo, durante carregamento oclusal. Diante disso, este trabalho avaliou qualitativa e quantitativamente o desempenho biomecânico de próteses fixas metaloplásticas parafusadas, unidas e isoladas, sobre implantes de diferentes comprimentos, posicionados na região posterior da mandíbula, por meio do método de CID. A partir de quatro modelos mestres, foram confeccionados quatro modelos em resina de poliuretano F16, simulando extremidade livre mandibular, com o dente 44 em resina (Luxatemp) e os dentes 45, 46 e 47 substituídos por implantes curtos (4 x 5 mm) e/ou convencionais (4 x 11 mm). Os grupos (G) deste estudo foram: G1 (dois implantes convencionais [45 e 46] e um curto [47]), G2 (um implante convencional [45] e dois curtos [46 e 47]), G3 (três implantes curtos) e G4 (três implantes convencionais). Próteses fixas metaloplásticas unidas e isoladas foram parafusadas sobre os intermediários e submetidas a diferentes carregamentos oclusais de 250N: puntiforme (distal do 47 e mesial do 45) e oclusal distribuído. Tensões na direção horizontal (&epsilon;xx) foram calculadas e comparadas qualitativa e quantitativamente pelo software de CID (Davis 8.0, LaVision GmbH). Em geral, houve uma concentração de tensões em maior intensidade nas áreas onde os implantes curtos estavam posicionados. No carregamento puntiforme no segundo molar, houve uma predominância de tensões de compressão e tração nos planejamentos com coroas unidas e isoladas, respectivamente, e as tensões de maior magnitude foram encontradas no G2, G3 e G4 com coroas isoladas (p>0,05), apresentando valores mediados (&mu;S) equivalentes a 396,08, 360,45 e 354,04, respectivamente. No carregamento puntiforme envolvendo o segundo pré-molar, houve predominância de tensões de compressão em todos os planejamentos, com magnitudes mais elevadas nos grupos com coroas unidas (p<0,05). As simulações com carga oclusal distribuída revelaram, também, predominância de tensões de compressão em todos os planejamentos, com maior magnitude nos grupos com coroas unidas, sobretudo no G1 (-464,05±106,43) e G3 (-474,39±179,54) e com diferenças estatisticamente significantes em relação aos demais grupos (p<0,05). Dentro das limitações deste estudo, pode-se concluir que a esplintagem das coroas sobre múltiplos implantes promoveu maior concentração de tensões em torno dos implantes durante os carregamentos puntiforme no segundo pré-molar e oclusal distribuído, reforçando a necessidade de contato interproximal e ajuste oclusal efetivos para promover melhor distribuição das tensões. Adicionalmente, a combinação de implantes curtos e convencionais parece ser uma alternativa viável na reabilitação de áreas edêntulas posteriores com altura óssea reduzida. / In cases of severe vertical bone loss, especially in the posterior region of the mandible, the use of short implants associated with splinted resin-veneered fixed dental prostheses (FDPs) can be an alternative to bone graft surgery and better force transmission to the adjacent bone, respectively. Among the methods to evaluate the stress distribution around the implants, the digital image correlation (DIC) has advantages as regards the possibility of evaluating the stress distribution continuously using images taken over time, during occlusal loading. Thus, this study evaluated qualitatively and quantitatively the biomechanical behavior of splinted and non-splinted resin-veneered FDPs, screw-retained on implants of different lengths positioned in the posterior region of the mandible with the aid of the DIC method. Four F16 polyurethane resin models were fabricated to simulate half of the mandibular arch containing tooth 44 in resin (Luxatemp) and teeth 45, 46 and 47 replaced by short (4 x 5 mm) and/or conventional (4 x 11 mm) implants. Groups (G) of this study were: G1 (two conventional implants [45 and 46] and one short implant [47]), G2 (one conventional implant [45] and two short implants [46 and 47]) G3 (three short implants) and G4 (three conventional implants). Splinted and non-splinted FDPs were screwed to the implant abutment and subjected to different oclusal loads of 250N: punctiform (45 mesial and 47 distal) and balanced occlusal load. Strains in the horizontal direction (&epsilon;xx) were calculated based on displacement and compared qualitatively and quantitatively by the DIC software (Davis 8.0, LaVision Inc.). In general, there was a stress concentration at higher intensity in those areas where short implants were placed. In punctiform load on the second molar, there was a compressive and tensile stresses predominance when splinted and non-splinted crowns were used, respectively, and the stresses of greater magnitude were found in the G2, G3 and G4 with non-splinted crowns (p>0.05), showing median values (&mu;S) equivalent to 396.08, 360.45 and 354.04, respectively. In punctiform load involving the second premolar, there was a compressive stress predominance in all planning with highest magnitudes in groups with splinted crowns (p<0.05). The oclusal load distributed simulations also revealed compressive stresses predominance in all planning, with greater magnitude in groups with splinted crowns, especially in G1 (-464.05 ± 106.43) and G3 (-474.39 ± 179.54), both with statistically significant differences when compared to the other groups (p<0.05). Within the limitations of this study, it can be concluded that splinting multiple adjacent implant supported provided a high stress concentration around the implants during punctiform (45 mesial) and balanced occlusal load, reinforcing the need for effective interproximal contact and oclusal adjustment to promote better stress distribution. Additionally, the combination of short and conventional implants seems to be a viable alternative in the rehabilitation of mandibular free end with reduced bone height.

Page generated in 0.048 seconds