• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 243
  • 11
  • 11
  • 11
  • 11
  • 10
  • 7
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 256
  • 130
  • 110
  • 98
  • 68
  • 59
  • 58
  • 57
  • 49
  • 44
  • 38
  • 29
  • 29
  • 29
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Um balanço do processo de privatização do sistema de telefonia fixa e móvel no Brasil

Althaus Junior, Adalto Acir January 2002 (has links)
O presente trabalho objetiva identificar a influência das privatizações na evolução do sistema de telefonia fixa e móvel celular brasileiro. O estudo foi desenvolvido avaliando-se um período de três anos pré-privatização versus pós-privatização, desconsiderando-se o ano em que ocorreu a troca do controle acionário das companhias. Para a execução do estudo, utilizou-se duas amostras distintas, uma para cada período, que representavam parcelas semelhantes da receita total do mercado para os respectivos períodos antes e pós-privatização. De modo a atingir o objetivo central do trabalho, desenvolveu-se o tema em quatro aspectos: desempenho das empresas de telefonia, qualidade e universalização dos serviços de telefonia, geração de divisas para o governo pelas empresas de telefonia e variação nos preços dos serviços de telefonia fixa. Para operacionalizar a análise, utilizou-se um conjunto de indicadores para cada um dos aspectos abordados e aplicou-se, primeiramente, o teste não-paramétrico de Kolmogorov- Smirnov. Em seguida, constatou-se que a forma de distribuição dos dados, antes desconhecida, atendia aos pressupostos dos testes paramétricos e aplicou-se, também, aos conjuntos de indicadores o teste t de Student de modo a perceber diferenças mais sutis principalmente nos casos em que o primeiro teste não detectou diferenças significativas. A avaliação geral dos resultados tende a rejeitar a hipótese nula de que a privatização das empresas de telefonia não reverteu em ganhos para o Estado e a população em geral. Esta conclusão baseia-se na análise dos quatro conjuntos de indicadores que apresentaram as seguintes evidências: em geral, a maioria dos indicadores de desempenho das empresas sinalizam uma queda em sua performance entre antes e depois das privatizações; a análise dos indicadores de qualidade e universalização dos serviços apresentaram sensível melhora, evidenciando uma evolução em termos de qualidade e de popularização dos serviços de telefonia; os indicadores de geração de divisas para o Estado apresentaram um crescimento no montante absoluto arrecadado, mas sem um aumento significativo na proporção da carga tributária incidente; a análise da evolução dos preços dos serviços de telefonia fixa revela que, considerando-se os efeitos inflacionários, houve uma redução destes preços no período pós-privatização comparando-se com o período pré-privatização.
92

Avaliação da distorção linear em estruturas métalicas de próteses sobre implantes: fundidas em peça única e em segmentos soldados a laser e através da soldagem convencional (brasagem)

Costa, Elza Maria Valadares da [UNESP] 29 June 2001 (has links) (PDF)
Made available in DSpace on 2018-07-27T18:25:55Z (GMT). No. of bitstreams: 0 Previous issue date: 2001-06-29. Added 1 bitstream(s) on 2018-07-27T18:29:54Z : No. of bitstreams: 1 000138043.pdf: 3009336 bytes, checksum: 4461e732807121379a46347a761b1f11 (MD5) / Próteses sobre implantes osseointegrados requerem critério de fabricação preciso devido a ausência de tecidos periodontais que compensam erros menores de relacionamento. Para tanto, em um arco mandibular edêntulo, construído em aço-cromo, foram fixados cinco análogos de pilares de implante, paralelos entre si, com distância de 10mm medidos de centro a centro. Sobre estes foram parafusados novos cilindros de ouro, com torque de 10 N/cm. Então foram executadas 15 sobre-estruturas metálicas que foram divididas: GC - Adaptação passiva dos cilindros de ouro; GM - monobloco GB - segmentos soldados por brasagem e, GL - segmentos soldados a laser. Observou-se as estruturas parafusadas com parafusos sempre novos sob microscópio de mensuração. A medição foi realizada na vestibular e lingual da interface cilindro/análogo e dados anotados em tabela apropriada. Para o eixo y, a técnica de soldagem a laser (Media=12,41 e Dp=11,12) produziu menos distorção significativamente do que a técnica de brasagem (Media=23,06 e Dp=13,31) seguida pela técnica de monobloco (Media=39,83 e Dp=21,88) p= 0.05. Para o eixo x, somente o grupo Monobloco apresentou diferença significativa para as demais técnicas (Média= 45,66 e Dp=21,56) / Prosthesis above osseointegrated implants requires an accurate criterion of manufacture. So, in an edentulous mandibular arch, constructed with chromium steel, five analogous were fixed, parallels, with distance of 10 mm measured of center to center. Above these gold cylinders were positioned and screwed with a torque of 10 N/m. In the next follow, fifteen over structures were fabricated and divided in tour groups: CG - Passive adaptation of gold cylinders; MG - Monobloc casting; BG - Casting in segments after brasing; LG - Casting in segments after laser welding. The structures were observed with measures microscope and the data noted in specific table. The measures done in two points (left and right) in the buccal and lingual surfaces of the interface of the cylinder/analogous set in the x and y-axis. The statistics analysis (ANOVA) showed significant statistics differences, on y-axis, among groups: LG group was superior to BG and this was superior to MG group and on x-axis only MG was superior to others groups (when we studied distortion.)
93

Análise comparativa das tensões e deformações entre próteses implantossuportadas de três elementos com dois ou três pilares /

Nishioka, Gabriela Nogueira de Melo. January 2016 (has links)
Orientador: Guilherme de Siqueira Ferreira Anzalone Saavedra / Banca: Alberto Noriyuki Kojima / Banca: José Scarso Filho / Resumo: O objetivo deste estudo foi avaliar as tensões e deformações in vitro, por meio da fotoelasticidade e da extensometria, em próteses parciais fixas implantossuportadas de três elementos variando o número de pilares: dois e três. O primeiro bloco de poliuretano (modelo mestre 1) recebeu três implantes e o segundo (modelo mestre 2) recebeu dois implantes, todos de hexágono externo. Em seguida, os modelos mestre foram duplicados em resina fotoelástica. Pilares protéticos microunit foram conectados aos implantes com torque de 20 Ncm. Sobre os pilares protéticos dos modelos mestre foram parafusados cilindros plásticos, que receberam estruturas em padrões de resinas, os quais foram fundidos em liga de Ni-Cr (n=10). Quatro extensômetros foram colados na superfície de cada bloco de poliuretano, tangenciando os implantes. Nos modelos mestre e nos modelos fotoelásticos, cada estrutura metálica foi parafusada sobre os pilares protéticos com torque de 10 Ncm. Os dados obtidos na extensometria foram submetidos aos testes estatísticos RM ANOVA e Tukey (5%). As franjas isocromáticas obtidas nos modelos fotoelásticos após cada condição de carga foram registradas com uma câmera digital, visualizadas em um programa de computador e comparadas qualitativamente. Resultados: Houve uma diferença estatística significante entre a quantidade de suporte de uma prótese fixa (p=0,001). Os resultados revelaram que três implantes apresentaram uma melhor distribuição das cargas em qualquer ponto analisado e ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The present study used photoelastic and strain gauge analysis to compare stress and microstrain to perform an in vitro evaluation of the effect of the numbers of support in a implant-supported fixed partial prostheses with tree elements. The first polyurethane block (master model 1) will contain three implants and the second block (model 2) two of them, all implants have a external hexagon. Then, the master models were duplicated in photoelastic resin. Microunit abutments were connected to the implants and received a 20 Ncm torque. Over the master model plastic prosthetic cylinders were screwed the abutments that received standard patterns cast in Ni-Cr alloy (n=10). Four strain gauges (SG) were bonded in the surface of the block, tangentially to the lateral implants. On the master model and photoelastic model, each metallic structure were screwed onto the abutments with a 10 Ncm torque. The data obtained from the strain gauge were analyzed statistically by RM ANOVA and Tukey's test, with a 5% conventional level of significance. The isochromatic fringes obtained in the photoelastic models after each load condition were recorded with a digital camera, visualized with software to facilitate qualitative analysis. Results: There was statistically significant differences in support of FPD( p=0,001).The results demonstrated that 3 implants has higher stress distribution and in the pontic of FPD we found higher stress (2326,95µε in 2 implants and 1006,57µε in 3 implants).In photoelastic images, 3 implants presented better stress distribution than 2 implants. Conclusions: Both methods found similar results. This study suggests ....(Resumo completo, clicar acesso eletrônico abaixo) / Mestre
94

Comportamento biomecânico de implantes retos e angulados sobre cargas axiais e não axiais por análise de elementos finitos e extensometria linear /

Tribst, João Paulo Mendes. January 2017 (has links)
Orientador: Renato Sussumu Nishioka / Banca: Alexandre Luiz Souto Borges / Banca: Francisley Ávila Souza / Resumo: Este trabalho buscou estudar as microdeformações geradas ao redor de implantes de hexágono externo durante carregamentos axiais e não axiais, variando-se a angulação dos implantes, utilizando a análise por elementos finitos e a extensometria linear como ferramentas. Inicialmente modelos 3D de diferentes próteses fixas foram construídos a fim de se permitir uma correlação dos resultados encontrados no modelo simplificado com o modelo anatômico e assim validar a geometria da prótese utilizada no estudo. Após a confirmação dos resultados de tensão similar entre as próteses na região dos implantes e do bloco, o modelo da prótese simplificada foi definida como válida. Em seguida, um modelo de bloco de poliuretano foi criado e duplicado. Implantes com conexão de hexágono externo (HE) foram modelados e em um bloco representados perpendiculares à superfície enquanto que em outro bloco foram colocados com inclinação de 17°. Foram modelados também intermediários do tipo mini pilar cônico retos e angulados conforme a inclinação dos implantes. Por último, foi utilizado o modelo de supraestrutura previamente validada para ambos os grupos, na qual a carga foi incidida. Todos os constituintes foram considerados perfeitamente simétricos, sólidos, isotrópicos. Os modelos receberam cargas de 300 N/cm em pontos axiais e não axiais através do software de análise por elementos finitos para se verificar a tensão máxima principal e as microdeformações. Em seguida, através da análise experimental de... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract:This Work aimed to study the microstrains generated around external hexagon implants during axial and non-axial loads, varying the angulation of the implants, using finite element analysis and linear strain gauge as tools. Initially 3D models of different fixed prostheses were constructed in order to allow a correlation of the results found in the simplified model with the anatomical model and thus validate the geometry of the prosthesis used in the study. After confirming the results of similar stress between the prostheses in the implants and the block region, the simplified prosthesis was defined as valid. After, a polyurethane block model was created and duplicated. Implants with external hexagon connection (HE) were modeled and inserted perpendiculary into one block while in another block, were placed with the inclination of 17 °. Straight and angled mini conical abutments were also modeled according to the inclination of the implants. Finally, the supra-structure previously validated for both groups was used, through which the load was affected. All constituents were considered perfectly symmetrical, solid, and isotropic. The models received a load of 300 N / cm in axial and non-axial points through the finite element analysis software, to verify the maximum principal stress and microstrains. Then, through the experimental analysis of strain-gauge, two polyurethane blocks were prepared and received three HE implants each, as well as respective mini tapered pillars according to the inclination of the installed implants. Then, a metallic superstructure, identical to the computational model, was cast in Ni-Cr and screwed onto the implants with torque of 10 N / cm. The load of 300 N / cm was applied for 10 seconds at axial and non-axial points. To measure the microstrains, four extensometers were glued on the surface of....(Resumo completo, clicar a acesso eletrônico abaixo) / Mestre
95

Estudo da densidade óptica e da resistência à flexão de três pontos em corpos-de-prova fundidos com a liga metálica High Bond (Co-Cr), com secções vertical 90°, diagonal 45° e diagonal 22,5°, soldados pelas técnicas convencional e TIG /

Pereira, Leonardo Viana. January 2012 (has links)
Orientador: Stefan Fiuza de Carvalho Dekon / Banca: Marco Polo Marchese / Banca: Gilberto Aparecido Coclete / Resumo: O sucesso das próteses sobreimplantes está diretamente relacionado ao grau de adaptação dos componentes protéticos aos implantes. Com a finalidade de se obter um assentamento passivo entre a prótese e os implantes, as estruturas metálicas são confeccionadas inicialmente segmentadas e, posteriormente, soldadas clinicamente para minimizar as distorções do processo de fundição. O sistema TIG (Tungsten Inert Gas) é definido como uma soldagem de arco elétrico, estabelecido entre um eletrodo não consumível à base de tungstênio e a peça a ser soldada. O propósito desse estudo foi, através do uso da densidade óptica e de um teste mecânico de resistência à flexão de 3 pontos, analisando a rigidez do material e a tensão de flexão, verificar o comportamento de dois sistemas de soldas odontológicas: convencional e TIG, realizadas em diferentes angulações (90°, 45° e 22,5°) de secções das porções a serem soldadas, comparando-os a um grupo fundido em monobloco (controle), em uma liga de Co-Cr. Os grupos foram comparados entre si quanto à densidade óptica, rigidez, tensão de flexão. A análise dos resultados obtidos possibilitou as seguintes conclusões: 1. Em relação à análise dos dados da densidade óptica mostrou que o grupo controle apresentou-se mais eficientes, estatisticamente significantes, quando comparadas aos grupos do sistema de solda TIG; não houve diferenças estatisticamente significantes entre as diferentes angulações num mesmo sistema de soldagem, porém quando comparados os sistemas de soldagem numa mesma angulação, o grupo de 22,5°-solda convencional teve resultado melhor, estatisticamente significante, que o 22,5°-solda TIG; 2. Em relação à rigidez (modulo de elasticidade), houve diferença estatisticamente significante apenas quando se comparou os corpos com angulação de 90° com diferentes soldas, tendo resultados maiores com ... / Abstract: The success of the prosthesis over implant is directly related to the adaptation degree of the prosthesis components to implants. Aiming to obtain a passive fit between the prosthesis and the implant, initially the metal structures are segmented and later are clinically welded to minimize the distortions of the casting process. The TIG system (Tungsten Inert Gas) is defined as a welding of an electric arc, established between a non consumable electrode based on tungsten and the part to be welded. The purpose of this study was to use the optical density and a mechanical test of 3 points flexion endurance, to analyze the stiffness of the material and the bending stress and to verify the behavior of two systems of dental welders: conventional and TIG performed at different angles (90º, 45º e 22, 5º) of the sections of the portions to be welded, and compare them to a group fused on monobloc (control) in an alloy of Co-Cr. The groups were compared on optical density, stiffness and bending stress. Analysis of the results made possible the following conclusions: 1. The analysis of the data showed that the optical density of the control group was more efficient, statistically significant, when compared to the groups with TIG welding system; there were no statistical differences between the different angles on the same welding system, although when comparing the welding systems in the same angle, the group of 22,5º- conventional welding had better result than the 22,5º - TIG welding, this difference was statistically significant; 2. There was statistical significant difference regarding the stiffness (modulus of elasticity) only when it was compared the bodies with the 90º angle with different welds, the higher results were with the conventional welding; 3. The results of the... / Mestre
96

Análise das volatilidades dos mercados brasileiros de renda fixa e renda variável no período 1986 - 2006 / Study of the volatility of the fixed income market and the stock market in Brazil in a period of 1986-2006

Nara Rossetti 14 December 2007 (has links)
O presente trabalho tem como objetivo analisar a volatilidade dos mercados de renda fixa e renda variável no Brasil, no período de março de 1986 até fevereiro de 2006, por meio do CDI (Certificado de Depósito Interfinanceiro) e IRF-M (Índice de Renda Fixa de Mercado), como indicadores do mercado de renda fixa, e o IBOVESPA (Índice da BOVESPA), como indicador de renda variável. Por meio da comparação da volatilidade destes ativos é possível observar se há coincidência temporal entre os dois mercados, em relação aos picos de volatilidade devido, principalmente, a influência de variáveis macroeconômicas. Tal análise é importante para que os gestores de portfólios, que tomam decisões de como alocar os investimentos, conheçam o histórico e o corrente relacionamento entre as volatilidades dos dois mercados. As volatilidades do mercado de renda fixa e do mercado de renda variável foram calculadas por meio do desvio padrão anual dos retornos mensais e por meio de um modelo GARCH(1,1). Os resultados mostram que, no Brasil, durante o período analisado, os dois mercados apresentaram: períodos coincidentes de picos de volatilidade, grande mudança no padrão comportamental das volatilidades após a implantação do Plano Real e pouca estabilidade na relação entre as volatilidades. / This work aims to study the volatility of the fixed income market and the stock market in Brazil, from March 1986 to February 2006, through CDI (Interbank Interest Rate), IRF-M (Fixed Income Index), as a fixed income market indicators, and IBOVESPA (BOVESPA index), as a stock market indicator. Through the comparison of the volatility of these assets it is possible to observe if there is time frame coincidence between the two markets, in relation to the peaks of volatility due to, mainly the influence of macroeconomics variables. Such analysis is important so that portfolio managers, responsible for decisions such investments allocation, know the history and the actual relationship between the markets volatility. Such analysis is important so that portfolio managers, responsible for decisions such investments allocation, know the history and the actual relationship between the markets volatility. Those fixed income market and stock markets volatilities were calculated through the annual standard deviation of the monthly returns and from a GARCH(1,1) model. The results show that, in Brazil, during the studied period, both markets presents: coincident volatility peaks periods, high change in the behavioral pattern of volatility after the deployment of the Plano Real and little stability in the relationship between the volatility.
97

Caracterização do nanocompósito de Al2O3 com inclusões nanométricas de ZrO2 visando sua aplicação como reforço em próteses odontológicas de cerâmica livre de metal / Characterization of al2o3 with nanometric zro2 inclusions nanocomposite reinforcing metal-free dental prosthesis

Pierri, Juliano de 22 February 2008 (has links)
Made available in DSpace on 2016-06-02T19:12:07Z (GMT). No. of bitstreams: 1 3329.pdf: 6374994 bytes, checksum: a47986d4181e05b6e83318ff5e2d9a33 (MD5) Previous issue date: 2008-02-22 / Financiadora de Estudos e Projetos / There are many different materials used in dental prosthesis, metal combined with ceramic (metalloceramic), combination of polymers with metal (metal-polymer), metal, polymer and ceramic metal free or metal-free. Metalfree dental prostheses, including crowns and bridges, are attractive to dentists and patients because they have better aesthetics, abrasion resistance, biocompatibility and low thermal conductivity when compared with traditional metal-ceramic prostheses. However, mechanical failures may occur because they are fragile materials. Zirconia (ZrO2) and alumina (Al2O3) are ceramics that have mechanical and aesthetic features suitable for manufacture of these prostheses. In the late 80's, were obtained significant improvements in mechanical properties of composites consisting of alumina matrix with nanoscale inclusions. Previous experimental results showed that the addition of small amounts of nanometric zirconia to the alumina sets a material with interesting mechanical properties. This study proposes the use of composites with nanoscale inclusions of zirconia as a material for the preparation of metalfree dental prostheses. To check this possibility, alumina matrix nanocomposites samples were prepared with 5% of nanometric inclusions of ZrO2 to test the biocompatibility in vivo and some mechanichal properties. In the mechanical characterization tests were performed under 3 point bending (according to ISO 6872/97) and diametral tensile test. Biocompatibility tests were performed on bone and subconjunctival tissue of rats. The results showed that, in accordance with the standards in dentistry and compared with values observed in previous studies, the material in this study has excellent mechanical properties and excellent biocompatibility which allows its use as reinforcement in metal-free dental prostheses. / Existem inúmeros diferentes materiais usados em próteses odontológicas: metal combinado com cerâmica (chamadas metalocerâmicas), combinação de metal com polímeros (metaloplásticas), metálicas, poliméricas (com ou sem carga) e cerâmicas também chamadas metal free ou livres de metal. As próteses odontológicas livres de metal, incluindo coroas e pontes, são atrativas aos dentistas e pacientes pois possuem melhor estética, resistência a abrasão, biocompatibilidade e baixa condutibilidade térmica quando comparadas com as tradicionais próteses metalo-cerâmicas. No entanto, falhas mecânicas podem ocorrer nestes materiais pois são materiais frágeis. As cerâmicas que apresentam caracterísitcas estéticas e mecânicas adequadas para a confecção destas próteses são a zircônia (ZrO2) e a alumina (Al2O3). No final da década de 80, foram obtidas melhoras significativas nas propriedades mecânicas de compósitos formados por matriz de alumina com inclusões nanométricas. Resultados experimentais prévios, demonstraram que adições de pequenas quantidades de zircônia nanométrica à alumina permite obter um material com propriedades mecânicas adequadas. O presente estudo propõe a utilização de compósitos com inclusões nanométricas de zircônia como material para a preparação de próteses odontológicas livres de metal.Tendo como objetivo verificar tal possibilidade, foram preparadas amostras de nanocompósitos de matriz de alumina com 5% de inclusões nanométricas de ZrO2 para a realização de ensaios de resistência mecânica e de biocompatibilidade in vivo . Na caracterização mecânica foram realizados ensaios de flexão em 3 pontos (de acordo com a norma ISO 6872/97) e ensaio de tração diametral. Já os ensaios de biocompatibilidade foram realizados em tecido ósseo e subconjuntivo de ratos. Os resultados mostraram que, de acordo com as normas vigentes em odontologia e comparativamente com valores observados em trabalhos anteriores, o material em estudo apresenta excelentes propriedades mecânicas e excelente biocompatibilidade o que possibilita seu uso como reforço de próteses livres de metal.
98

Comportamento sob fadiga de restaurações cerâmicas ultrafinas cimentadas adesivamente em preparos correspondentes aos dentes posteriores / Fatigue behavior of ultrafine tabletop posterior ceramic restorations adhesively cemented

Abu-Izze, Fernanda de Oliveira 01 December 2017 (has links)
Submitted by FERNANDA DE OLIVEIRA ABU-IZZE null (fefeizze@hotmail.com) on 2018-03-12T22:56:56Z No. of bitstreams: 1 12.01.18 biblio correção final.pdf: 10328694 bytes, checksum: 640b2d0c989c903e0216bd6a154400e4 (MD5) / Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2018-03-20T20:51:39Z (GMT) No. of bitstreams: 1 abu_izze_fo_me_sjc.pdf: 10328694 bytes, checksum: 640b2d0c989c903e0216bd6a154400e4 (MD5) / Made available in DSpace on 2018-03-20T20:51:39Z (GMT). No. of bitstreams: 1 abu_izze_fo_me_sjc.pdf: 10328694 bytes, checksum: 640b2d0c989c903e0216bd6a154400e4 (MD5) Previous issue date: 2017-12-01 / A fim de investigar a vida em fadiga, modos de falha e distribuição de tensões de restaurações ultrafinas parciais, tipo tabletop, em diferentes cerâmicas, sessenta preparos padronizados foram confeccionados em resina epóxi G10 e foram cimentadas adesivamente restaurações cerâmicas de silicato de lítio reforçado com zircônia (ZLS, Vita Suprinity- Vita Zahnfabrik), ou restaurações de cerâmica híbrida (PIC, Vita Enamic- Vita Zahnfabrik), em 0,5 ou 1 mm de espessura. O mesmo protocolo de ciclagem foi aplicado para todos os espécimes, que consistiu em 5.000 ciclos a 200 N, seguidos de 450 N ciclos até a fratura dos espécimes ou a suspensão do teste após 1,5 x 106 ciclos. A carga axial foi realizada com uma freqüência de 4 Hz no equipamento Biocycle V2 (Biopdi, São Carlos, SP), com amostras imersas em água. A presença de falhas e/ou fraturas foi verificada a cada 2,5 x 105 ciclos e a análise de sobrevivência foi realizada com o número de ciclos em que cada espécime falhou. Os espécimes foram avaliados usando estereomicroscópio e microscopia eletrônica de varredura (MEV). Após a tabulação de dados, foram realizados Kaplan-Meier e Mantel-Cox (Teste Log Rank), seguindo de comparação múltipla aos pares, todos com nível de significância de 5% e análise de Weibull. Através da análise tridimensional de elementos finitos, a distribuição de tensões máximas principais (TMP) nas tabletop oclusais posteriores foram avaliados comparando diferentes tipos de substrato (G10, esmalte/dentina, esmalte), espessuras e materiais cerâmicos. As restaurações de silicato de lítio reforçadas com zircônia com 0,5 mm de espessura (ZLS.5) apresentaram menor resistência à fadiga em comparação com restaurações cerâmicas híbridas de 1,0mm (PIC1), e ambas foram similares a outras restaurações (PIC.5 e ZLS1); X2 = 11,2; df = 3; p = 0,0107 <0,05). Os grupos ZLS apresentaram defeitos aleatórios que culminaram com a fratura, ao passo que os grupos PIC apresentaram defeitos que aumentaram com a fadiga mecânica após algum tempo sob ciclagem. As imagens do estereomicroscópio mostram falhas radiais observadas devido à translucidez do material, não houve danos causados pelo aplicador de carga. A distribuição de TMP foi semelhante para os diferentes tipos de substrato, mas o maior módulo de elasticidade mostrou uma concentração de tensão ligeiramente menor. É favorável o uso de PIC em espessura delgada, com resistência à fadiga semelhante à restaurações de ZLS mais espessas. / To investigate the fatigue life, failure modes and stress distribution of partial ultrafine restorations for posterior teeth in different ceramics, sixty standard tabletop preparations in epoxy resin G10 received lithium silicate based zirconia reinforced (ZLS, Vita Suprinity- Vita Zahnfabrik), or hybrid ceramic (PIC, Vita Enamic- Vita Zahnfabrik), restorations in .5 or 1 mm thickness bonded using resin cement. The same cycling protocol was applied for all specimens that consisted of 5.000 cycles at 200 N followed by 450 N cycles until the specimens’ fracture or the suspension of the test after 1.5 x 106 cycles. Axial load was carried out with a 4 Hz frequency in Biocycle V2 equipment (Biopdi, São Carlos, SP), with samples immersed in water. Presence of cracks and/or fractures was checked with every 2,5 x 105 cycles and the survival analysis was performed using the number of cycles in which each specimen failed. All specimens were evaluated using stereomicroscope and scanning electron microscopy (SEM). After data tabulation, Kaplan-Meier and Mantel-Cox (Log Rank test) analysis were performed, followed by multiple pairwise comparison, all with a significance level of 5%, and Weibull analysis. Through tridimensional finite element analysis, stresses distribution and maximum principal stresses in the posterior occlusal veneers were evaluated comparing different types of substrate (G10, enamel/dentin, enamel), thicknesses and ceramic materials. Zirconium-reinforced lithium silicate restorations with 0.5 mm thickness (ZLS.5) showed lower fatigue strength compared to 1.0 mm hybrid ceramic restorations (PIC1), and both were similar to other restorations (PIC.5 and ZLS1) (Log-Rank test, X2 = 11.2; df = 3; p = 0.0107<0.05). ZLS groups presented random defects that culminated with the fracture, whereas PIC groups presented defects that increased with the mechanical fatigue after some time under cycling. Stereomicroscope images show radial cracks observed due to the translucency of the material, there was no damage caused by applicator. TMP distribution was similar for the different substrate types, but the highest modulus of elasticity showed slightly lower stress concentration. PIC is favorable to be used in thin thickness with similar fatigue strength to thicker ZLS restorations.
99

Avaliação da precisão de aquisição de dados nos Sistemas CAD/CAM : desadaptação marginal horizontal /

Lopes, Leonardo Ferreira de Toledo Piza. January 2015 (has links)
Orientador: Eduardo Piza Pellizzer / Coorientador: José Vitor Quinelli Mazaro / Banca: Fellippo Ramos Verri / Banca: Sandra Lúcia Dantas de Moraes / Resumo: Objetivo: O objetivo deste estudo foi avaliar a adaptação marginal horizontal de infraestruturas de próteses fixas confeccionadas pelo sistema CAD-CAM com três diferentes sistemas de aquisição de dados. Material e Métodos: Foram confeccionados 50 corpos de prova divididos em 5 grupos, sendo eles, Convencional (Ni-Cr); GI: iTero; GII: CerecBluecam/fresadora industrial; GIII: 3S; GIV: CerecBluecam/ fresadora Sirona, todos com n=10. Os corpos de prova foram numerados e randomizados, realizou-se análise da desadaptação marginal horizontal, esta dividida em positiva para sobre-contorno e negativa para subcontorno. Resultados: A análise intra-examinador revelou não haver diferença estatística entre os dois períodos de análise (t pareado=0.019; p=0.985). Em relação as desadaptações de sobre-contorno (valores positivos) podemos analisar que o grupo controle (Convencional) apresentou estatisticamente (p <0.001) menores valores de desadaptação (82 μm) quando comparado com o grupo CAD/CAM (144 μm). Ao comparar o sistema intra/extra-oral pode-se observar que o grupo intra-oral (iTero) apresentou melhores resultados, sendo essa diferença estatisticamente significante (p <0.001) que o extra-oral (3s). Já avaliando a diferença entre um sistema aberto com um fechado foi observado que o sistema aberto apresentou estatisticamente menor desadaptação (p<0.001). Quando avaliou-se a "quebra" de um sistema fechado (Cerec BlueCam) para sua fresagem a nível industrial notou-se que há desvantagens em tal procedimento, pois houve estatisticamente maiores desadaptações no grupo da "quebra" do sistema (p<0.001). Em contra partida nenhuma diferença estatisticamente significante foi encontrada em todas as análises quando se comparou desadaptação por sub contorno. Significância: Avaliando a discrepância... / Abstract: Objective: The aim of this study was to evaluate the horizontal marginal fit of frameworks produced by CAD/CAM systems with 3 different data acquisition. Material and Methods: We fabricated 50 frameworks divided into 5 groups, Conventional (Ni- Cr); GI: iTero; GII: CerecBluecam/industrial milling; GIII: 3S; GIV: CerecBluecam/Sirona, all with n = 10. We numbered the specimens and analyzed them randomly. Results: Intra-observer analisys indicated no statistically significant difference (paired t-test=0.019; p=0.985). In relation to the overextended horizontal marginal discrepancy (Positive Values) can analyze that the Control group (Conventional) had significantly (p < 0.001) minor discrepancy values (82 μm) when compared to the CAD / CAM group (144 μm). When comparing the systems intra/extra oral can be appreciated that the intra oral group (Itero) presented statistically best results when comparing(p < 0.001) that the extra oral ( 3s ). Evaluating the difference between the open system with closed was observed that the open system had statistically smaller misfit (p < 0.001). Evaluating the "broke" of a closed system (Cerec Bluecam) your industrial milling had statistically (p < 0.001) worse adaptation when compared to the laboratorial milling. About the under extended marginal discrepancy, in all analysis there was not found statistically significant difference. Significance: Assessing the horizontal marginal discrepancy was possible to note that in relation to the overextended the control group had statistically better results than the CAD/CAM systems, however the Cerec Bluecam system by sirona milling had better results than all CAD/CAM system and also the control group. There was no difference between the under extended misfit and all analysis / Mestre
100

Determinação da resistência à flexão de ligas odontológicas, utilizadas em prótese parcial fixa e prótese sobre implante, soldadas por brasagem e a laser /

Dinato, José Cícero. January 1999 (has links)
Orientador: Marco Antonio Bottino / Banca: Paulo Afonso Burmann / Banca: Maximiliano Píero Neisser / Resumo: O objetivo deste trabalho foi determinar a resistência à flexão de sessenta corpos-de-prova cilíndricos, obtidos a partir de quatro ligas metálicas utilizadas em prótese parcial fixa e prótese sobre implante, disponíveis no mercado brasileiro (Co-span 13.5, Stabilor G, Deva 4 e Palliag M) medindo 25 mm de comprimento e 3 mm de diâmetro. Cinco corpos-de-prova de cada liga foram fundidos em monobloco, cinco soldados por brasagem e cinco a laser Nd-YAG, Dessa forma, obtiveram-se 15 corpos-de-prova para cada liga metálica, divididos em três grupos. No grupo I, os corpos-de-prova foram fundidos em monobloco; no grupo 2, soldados por brasagem; no grupo 3, soldados a laser. Após a conclusão dos corpos-de-prova, os três grupos foram submetidos a um ensaio de resistência flexural, em uma máquina de testes lnstron. O ensaio consistiu em submeter os corpos-de-prova a uma carga ao seu centro, com as suas extremidades apoiadas em dois cilindros separados por uma distância de 20 mm, de modo que sofressem a ação e reação da carga em apenas três pontos. A velocidade de aplicação da carga foi de 0,5 mm/min, com uma célula de carga de 500 kg. Os resultados numéricos obtidos foram submetidos à Análise de Variância e ao teste de Tukey, ao nível de 5% de probabilidade. Em vista dos resultados obtidos, conclui-se que o maior valor numérico da resistência flexural foi encontrado para a liga Co-span 13.5, seguido do Deva 4, para os grupos de soldagem a laser e monobloco. O material Palliag M apresentou valores estatisticamente semelhantes para os três grupos. A liga Stabilor G apresentou os melhores resultados no método por brasagem / Abstract: The mechanic properties of brazed joints compared with castings performed in monoblocks have been exhaustingly evaluated. The use of laser in Dentistry opened a new and promising field to study this type of fusion. The purpose of this study was to determine the flexural resistance of four types of metal alloys used in fixed partial prosthodontics (Co-span 13.5, Stabilor G, Deva 4 and Palliag M). Fifteen test specimens with 3 mm diameter and 25mm length were obtained by casting for each alloy, and divided in three groups (monoblocks, brazing and laser welding), totaling sixty cylindrical specimens. The specimens were submitted to GLP/O2 torch welding and Nd-YAG laser welding performed with a specific laser equipment (Laser 2002, Dentaurum, Germany). The results were compared with tests performed in monoblocks of these same materials. To determine the flexural resistance, an universal testing machine (Instrom, model 4301), with a 500 Kg maximum capacity was used. The results were statistically analyzed using an ANOVA and Tuckey'.s test in a 5% degree of probability. The results showed that the highest numeric value of flexural resistance was found with the Co-Span alloy, followed by Deva 4, for both laser welding and monoblock groups. Palliag M showed statistically similar values for the laser welding, brazing and monoblock groups, whereas Stabilor G presented its highest values in brazing / Mestre

Page generated in 0.047 seconds