• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 243
  • 11
  • 11
  • 11
  • 11
  • 10
  • 6
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 255
  • 130
  • 110
  • 98
  • 68
  • 58
  • 58
  • 57
  • 49
  • 44
  • 38
  • 29
  • 29
  • 29
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Extensometria: estudo das deformações ao redor de três implantes cone morse, com posicionamento linear, sob carga axial

Abreu, Celina Wanderley de [UNESP] 03 February 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-02-03Bitstream added on 2014-06-13T18:58:12Z : No. of bitstreams: 1 abreu_cw_me_sjc.pdf: 508442 bytes, checksum: 720d525ea366cc2fd0575e67a37ba04e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo desse estudo foi avaliar a aplicação de carga e distribuição das microdeformações ao redor de implantes com conexão protética cone morse. Três implantes foram inseridos num bloco de poliuretano e pilares microunit foram instalados nos implantes com torque de 20 Ncm. Três coifas usinadas foram adaptadas nos pilares para configurar a supraestrutura protética (n=5) e comparar com as supra-estruturas obtidas com coifas plásticas. Quatro extensômetros foram colados na superfície superior do bloco. Uma carga vertical estática de 30 Kg foi aplicada em cinco pontos das supra-estruturas. Os registros obtidos dos extensômetros foram submetidos ao teste estatístico ANOVA e Tukey (α=5%). As medidas derivadas dessa simulação revelaram que durante a aplicação de carga: (1) existiu uma relação direta do local de aplicação e na distribuição da microdeformação ao redor dos implantes; (2) não existiu diferença na microdeformação entre coifas plásticas e usinadas. / The aim of this study was to evaluate the load transfer and strain distribution by an implant-supported fixed partial prosthesis. Three implants Morse Taper were inserted in a polyurethane block and abutments microunit were installed on the implants with a torque of 20 Ncm. Plastic cylinders and prefabricated cylinders were adapted on abutments to fabricate the framework (n=5). Four strain gauges were attached on the superior surface of the block and then each framework was tight on the abutments with a torque of 10 Ncm and vertical load of 30Kg was applied to five points on the framework. The data obtained in the strain gauge analysis were submitted to the statistical tests ANOVA and Tukey (α=5%). The measurements derived from this simulation revealed that: (1) there was a direct proportion between the strain distribution in the metal framework and stresses created in the supporting structure around the implants; (2) there was not a strain difference between plastic and prefabricated cylinders during the load transfer
72

Estudo da densidade óptica e da resistência à flexão de três pontos em corpos-de-prova fundidos com a liga metálica High Bond (Co-Cr), com secções vertical 90°, diagonal 45° e diagonal 22,5°, soldados pelas técnicas convencional e TIG

Pereira, Leonardo Viana [UNESP] 06 September 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-09-06Bitstream added on 2014-06-13T19:58:25Z : No. of bitstreams: 1 000738161.pdf: 8215678 bytes, checksum: 0fb4df9ab1185429ce16edda73d5c2b2 (MD5) / O sucesso das próteses sobreimplantes está diretamente relacionado ao grau de adaptação dos componentes protéticos aos implantes. Com a finalidade de se obter um assentamento passivo entre a prótese e os implantes, as estruturas metálicas são confeccionadas inicialmente segmentadas e, posteriormente, soldadas clinicamente para minimizar as distorções do processo de fundição. O sistema TIG (Tungsten Inert Gas) é definido como uma soldagem de arco elétrico, estabelecido entre um eletrodo não consumível à base de tungstênio e a peça a ser soldada. O propósito desse estudo foi, através do uso da densidade óptica e de um teste mecânico de resistência à flexão de 3 pontos, analisando a rigidez do material e a tensão de flexão, verificar o comportamento de dois sistemas de soldas odontológicas: convencional e TIG, realizadas em diferentes angulações (90°, 45° e 22,5°) de secções das porções a serem soldadas, comparando-os a um grupo fundido em monobloco (controle), em uma liga de Co-Cr. Os grupos foram comparados entre si quanto à densidade óptica, rigidez, tensão de flexão. A análise dos resultados obtidos possibilitou as seguintes conclusões: 1. Em relação à análise dos dados da densidade óptica mostrou que o grupo controle apresentou-se mais eficientes, estatisticamente significantes, quando comparadas aos grupos do sistema de solda TIG; não houve diferenças estatisticamente significantes entre as diferentes angulações num mesmo sistema de soldagem, porém quando comparados os sistemas de soldagem numa mesma angulação, o grupo de 22,5°-solda convencional teve resultado melhor, estatisticamente significante, que o 22,5°-solda TIG; 2. Em relação à rigidez (modulo de elasticidade), houve diferença estatisticamente significante apenas quando se comparou os corpos com angulação de 90° com diferentes soldas, tendo resultados maiores com... / The success of the prosthesis over implant is directly related to the adaptation degree of the prosthesis components to implants. Aiming to obtain a passive fit between the prosthesis and the implant, initially the metal structures are segmented and later are clinically welded to minimize the distortions of the casting process. The TIG system (Tungsten Inert Gas) is defined as a welding of an electric arc, established between a non consumable electrode based on tungsten and the part to be welded. The purpose of this study was to use the optical density and a mechanical test of 3 points flexion endurance, to analyze the stiffness of the material and the bending stress and to verify the behavior of two systems of dental welders: conventional and TIG performed at different angles (90º, 45º e 22, 5º) of the sections of the portions to be welded, and compare them to a group fused on monobloc (control) in an alloy of Co-Cr. The groups were compared on optical density, stiffness and bending stress. Analysis of the results made possible the following conclusions: 1. The analysis of the data showed that the optical density of the control group was more efficient, statistically significant, when compared to the groups with TIG welding system; there were no statistical differences between the different angles on the same welding system, although when comparing the welding systems in the same angle, the group of 22,5º- conventional welding had better result than the 22,5º - TIG welding, this difference was statistically significant; 2. There was statistical significant difference regarding the stiffness (modulus of elasticity) only when it was compared the bodies with the 90º angle with different welds, the higher results were with the conventional welding; 3. The results of the...
73

Sistemas CAD/CAM: avaliação da precisão de aquisição de dados

Mello, Caroline Cantieri de [UNESP] 18 February 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:41Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-18Bitstream added on 2015-03-03T12:06:08Z : No. of bitstreams: 1 000795787.pdf: 571234 bytes, checksum: f635d0ca5e8e957bf53c65ab8998057a (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Objetivo: O objetivo deste estudo foi avaliar a adaptação marginal de infraestruturas de próteses fixas confeccionadas pelo Sistema CAD/CAM com três diferentes sistemas de aquisição de dados. Material e Métodos: Confeccionaram-se 50 corpos de prova; Convencional (Ni-Cr) (n = 10), GI: iTero (n = 10), GII: CerecBluecam/fresadora industrial (n = 10), GIII: 3S (n = 10) e GIV: CerecBlueCam/Sirona (n = 10). Os corpos de prova foram numerados e randomizados, realizou-se análise da desadaptação marginal vertical. Resultados: A análise intra observador indicou que não houve diferença estatisticamente significante (teste t pareado, p = 0.822) no período antes e depois das análises. O sistema convencional (321 ?m) apresentou maior desadaptação quando comparado com o sistema CAD/CAM (89 ?m) (p<0.001). O sistema intra oral (iTero) apresentou menor índice de desadaptação marginal, quando comparado com o sistema extra oral (3S), (p<0.001). O sistema aberto apresentou maior índice de desadaptação marginal (114 ?m) quando comparado com intra oral (iTero), sendo p<0.001. Além disto, no sistema convencional, observou-se que os pré-molares apresentaram índice de desadaptação maior quando comparado (361 ?m) com o molar (283 ?m) (p<0.001), porém no sistema CAD/CAM não houve diferença estatisticamente significante na comparação de dentes pré-molares (93,7 ?m) e molares (84,9 ?m). Significância: O sistema CAD/CAM pode atuar mais favoravelmente, reduzindo o índice de desadaptação marginal, quando comparado com o sistema convencional de confecção de próteses dentárias. O sistema intra oral (iTero) comportou-se melhor quando comparado com os demais sistemas. / Objective: The aim of this study was to evaluate the marginal fit of frameworks produced by CAD/CAM systems with three different data acquisition. Material and Methods: We fabricated 50 frameworks: conventional (Ni-Cr) (n = 10), GI:iTero (n = 10), GII:CerecBluecam/industrial milling (n = 10), GIII:3S (n = 10), and GIV:CerecBlueCam/Sirona (n = 10). We numbered the specimens and analyzed them randomly. Results: Intra-observer analysis indicated no statistically significant difference (paired t-test, p = 0.822) before and after the analysis. The conventional system (321 ?m) showed greater misfit than the CAD/CAM (89 ?m) (p<0.001) system. The intraoral system (iTero) showed a lower rate of marginal misfit than the extra-oral system (3S), (p<0.001). The open system presented a higher marginal discrepancy (114 ?m) than intraoral (iTero), with p<0.001. Moreover, in the conventional system, premolars (361 ?m) showed a higher index of misfit than molars (283 ?m) (p<0.001), but for the CAD/CAM system, there was no statistically significant difference between premolars (93.7 ?m) and molars (84.9 ?m). Significance: The CAD/CAM system can to act more favorably reducing the rate of marginal discrepancy than the conventional impression system of dental prosthesis. The intra oral system (iTero) was better than other systems. / FAPESP: 11/06311-5
74

Desenvolvimento e validação de novas tecnologias para o ensino de preparos em prótese parcial fixa / Development and validation of new technologies for teaching in preparations in fixed partial prosthesis

Gomes, Michelle de Sá dos Santos [UNESP] 15 August 2018 (has links)
Submitted by Michelle de Sá dos Santos Gomes (missg_13@hotmail.com) on 2018-10-10T01:00:45Z No. of bitstreams: 1 DISSERTAÇÃO MP POS DEFESA - com ficha!.pdf: 1982942 bytes, checksum: 2ffe88957cc63206ff9de30edbac3342 (MD5) / Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2018-10-15T18:44:48Z (GMT) No. of bitstreams: 1 gomes_mss_me_sjc.pdf: 1982942 bytes, checksum: 2ffe88957cc63206ff9de30edbac3342 (MD5) / Made available in DSpace on 2018-10-15T18:44:48Z (GMT). No. of bitstreams: 1 gomes_mss_me_sjc.pdf: 1982942 bytes, checksum: 2ffe88957cc63206ff9de30edbac3342 (MD5) Previous issue date: 2018-08-15 / O primeiro contato de alunos de graduação com a disciplina de Prótese Parcial Fixa ocorre em aulas teóricas e posteriormente em práticas laboratoriais. Na teoria os docentes utilizam de diversas formas para elucidar um preparo de Prótese Parcial Fixa, fotos e vídeos no passo a passo, guias de silicone, guias de redução, marcações coloridas e até mesmo demonstrações ao vivo. Utilizam- se desses métodos a fim de formar um conceito e fixar uma imagem de um preparo ideal obedecendo aos princípios mecânicos e biológicos das reduções estruturais em prótese fixa. O presente estudo teve como objetivo avaliar as principais dificuldades dos alunos de graduação nos preparos coronários em Prótese Parcial Fixa e sugerir ferramentas de ensino para auxiliar aluno e professor, a elucidar e calibrar os alunos nos desgastes coronários. Participaram da pesquisa ao todo 87 alunos matriculados do 3° ano integral, dos anos 2017 e 2018 da disciplina de Prótese Parcial Fixa, da graduação em Odontologia do ICT. Foi desenvolvido um aplicativo de celular com um banco de dados dos principais preparos coronários e com a possibilidade de comparação do preparo finalizado através de fotos. Também foram desenvolvidas, aplicadas e validadas 02 metodologias: Um manequim com esquema de cores que auxiliou o aluno a visualizar os preparos coronários e uma demonstração prática projetada comparou os métodos de ensino teórico e prático. 78,2% dos alunos relatam a quantidade de redução como a principal dificuldade. O método do manequim com esquema de cores foi preferência de técnica por 91,5% dos alunos. Ambos os métodos auxiliares didáticos avaliados foram aprovados pelos alunos, em 100% no método do manequim e 98,2% na vídeo aula. Respectivamente, os métodos auxiliaram na visualização da quantidade de redução e na sequência do preparo. Conclui-se que tanto o manequim com esquema de cores e a projeção ao vivo quanto o se mostraram eficazes e aprovados como recursos didáticos auxiliares no ensino de Prótese Parcial Fixa e o desenvolvimento do aplicativo de celular como ferramenta no ensino odontológico expande as possibilidades do uso de tecnologias de ensino na odontologia. / The first contact of undergraduate students with the discipline of Partial Fixed Prosthesis occurs in theory classes and later in laboratory practices. In theory, teachers use a variety of ways to elucidate a Fixed Partial Prosthesis preparation, step-by-step photos and videos, silicone guides, reduction guides, color markers and even live demonstrations. These methods are used to form a concept and to fix an image of an ideal preparation obeying the mechanical and biological principles of the structural reductions in fixed prosthesis. The present study had as objective to evaluate the main difficulties of undergraduate students in coronary arteries in Fixed Partial Prosthesis and to suggest teaching tools to help students and teachers to elucidate and calibrate students in coronary wear. A total of 87 enrolled students from the 3rd full year, from the years 2017 and 2018 of the discipline of Partial Fixed Prosthesis, from the graduation in Dentistry from the ICT participated in the research. A cellular application was developed with a database of the main coronary preparations and the possibility of comparing the finished preparation with photos. Two methodologies were also developed, applied and validated: a color design mannequin that helped the student to visualize the coronary preparations and a practical demonstration designed to compare the methods of theory and practical teaching. 78.2% of the students report the amount of reduction as the main difficulty. The method of color design mannequin was a technique preference for 91.5% of the students. Both didactic methods were approved by the students, 100% in the color design mannequin and 98.2% in the video lesson. Respectively, the methods aided in visualizing the amount of reduction and the preparation sequence. It was concluded that both the color-blind mannequin and the live projection were effective and approved as auxiliary didactic resources in the teaching of Partial Fixed Prosthesis and the development of the cellular application as a tool in dental education expands the possibilities of use of teaching technologies in dentistry.
75

Avaliação da adaptação marginal de copings cerâmicos obtidos por diferentes métodos de moldagem / Evaluation of the marginal adaptation of ceramic copings obtained by different molding methods

Pinto, Tatiana Saretta Ferreira [UNESP] 13 August 2018 (has links)
Submitted by Tatiana Saretta Ferreira Pinto (tatiorto13@hotmail.com) on 2018-10-11T15:04:44Z No. of bitstreams: 2 tese final para impressão.pdf: 1518062 bytes, checksum: f5bc8c4dd9de4a0b0698c8932e0aef20 (MD5) tese final para impressão.pdf: 1518062 bytes, checksum: f5bc8c4dd9de4a0b0698c8932e0aef20 (MD5) / Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2018-10-16T21:13:07Z (GMT) No. of bitstreams: 1 pinto_tsf_me_sjc.pdf: 1518062 bytes, checksum: f5bc8c4dd9de4a0b0698c8932e0aef20 (MD5) / Made available in DSpace on 2018-10-16T21:13:07Z (GMT). No. of bitstreams: 1 pinto_tsf_me_sjc.pdf: 1518062 bytes, checksum: f5bc8c4dd9de4a0b0698c8932e0aef20 (MD5) Previous issue date: 2018-08-13 / O objetivo desse estudo foi avaliar a adaptação marginal de copings cerâmicos obtidos pelos métodos de moldagem convencional e escaneamento. Os modelos foram separados em 3 grupos para avaliação e todas as coroas foram confeccionadas sobre um modelo mestre previamente fabricado em CoCr. Grupo 1: Com o auxílio de uma moldeira individual cilíndrica de acrílico foram reproduzidas 10 moldagens com silicona de adição (Panasil) no modelo mestre pela técnica de moldagem dupla e replicados dez modelos físicos em gesso pedra Fuji Rock.Sobre esses modelos foi realizado o enceramento dos copings, confecção dos sprues de cera e sobre eles foi realizada a injeção da cerâmica Grupo 2: foram realizadas 10 moldagens diretas com scanner extraoral (Swing Dental Scanner) no modelo mestre. As imagens foram obtidas através do software Exocad e copings em IPS-Emax CAD foram confeccionados em fresadora (Ceramill Motion 2) para posterior sinterização da cerâmica. Grupo 3: foram realizadas 10 moldagens diretas com scanner intraoral (CEREC Bluecam) no modelo mestre. As imagens foram obtidas através do software Exocad. Copings em IPS-Emax CAD foram confeccionados em fresadora (Ceramill Motion 2) para posterior sinterização da cerâmica. Os copings de cerâmica não foram cimentados no modelo mestre, apenas posicionados e mantidos com pressão constante de 1,4 a 1,5 kg durante a medição, com a ajuda de um delineador adaptado para esse trabalho, onde oito pontos eletivos foram usados como referência para medir a distância vertical entre a linha de término do modelo mestre e a linha de término dos copings. A margem em cada ponto foi medida 3 vezes com estéreomicroscópio Discovery V20 (ZEISS). A média de desadaptação marginal foi calculada e submetida ao teste de variância de um fator ANOVA com nível de significância de 5% e foram obtidos os seguintes resultados: 66,15µm para o grupo 1; 67,48µm para o grupo 2 e 72,91µm para o grupo 3,verificando assim que esses valores não diferem estatisticamente e todos estão dentro do limite de aceitabilidade clínica / The objective of the study was to evaluate the marginal adaptation of ceramic crowns obtained by conventional molding and scanning methods. The models were separated into 3 groups for evaluation and all the crowns were made on a master model previously manufactured in CoCr. For group 1: With the aid of a single cylindrical acrylic tray the master model was molded 10 times with Panasil in the master model by the technique of double molding and replicated ten physical models in stone gypsum Fuji Rock. On these models was done the waxing of the copings, making the sprues of wax and on them was carried out the injection of the ceramics In group 2, 10 direct impressions were performed with the Swing Dental Scanner (Korea) extra oral scanner in the master model. The images were obtained through the software Exocad (GmbH) and copings in IPS-Emax CAD were made in the Ceramill Motion 2 (Amanngirrbach) mill for subsequent sintering of the ceramics. In group 3, 10 direct impressions were performed with the CEREC Bluecam intraoral scanner (Sirona Dental Systems) in the master model. The images were obtained through the Exocad (GmbH) software. IPS-Emax CAD copings were made in the Ceramill Motion 2 (Amanngirrbach) mill for subsequent sintering of the ceramic. Ceramic copings were not cemented in the master model, only positioned and maintained with a constant pressure of 1.4 to 1.5 kg during the measurement, with the aid of an eyeliner adapted for this work, where eight elective points were used as reference to measure the vertical distance between the end line of the master model and the end line of the copings. The margin at each point was measured 3 times with stereo microscope Discovery V20 (ZEISS). The mean was calculated and submitted to the ANOVA variance test "with a significance level of 5% and the following results were obtained: 66.15μm for group 1; 67.48μm for group 2 and 72.91μm for group 3, thus verifying that these values do not differ statistically and all are within the limit of clinical acceptability.
76

Determinação da tensão de falha de lascamento da porcelana de cobertura em prótese livre de metal utilizando análise de imagem. / Determination of the failure stress of the porcelain chipping cover in metal free prosthesis using image analysis.

Silva, Elielson Nóbrega da [UNESP] 21 August 2018 (has links)
Submitted by Elielson Nobrega da Silva (nobrega_elielson@hotmail.com) on 2018-11-09T01:23:55Z No. of bitstreams: 1 Dissertação Ficha 08_11_1.pdf: 3453656 bytes, checksum: a1cff4951db4dde58ae977a59c6423b6 (MD5) / Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2018-11-19T18:56:22Z (GMT) No. of bitstreams: 1 silva_en_me_sjc.pdf: 3453656 bytes, checksum: a1cff4951db4dde58ae977a59c6423b6 (MD5) / Made available in DSpace on 2018-11-19T18:56:22Z (GMT). No. of bitstreams: 1 silva_en_me_sjc.pdf: 3453656 bytes, checksum: a1cff4951db4dde58ae977a59c6423b6 (MD5) Previous issue date: 2018-08-21 / A introdução da zircônia na Odontologia deu-se pela necessidade de melhores propriedades mecânicas dos materiais cerâmicos, pois com a crescente demanda estética, os cerâmicos tornaram-se materiais de largo uso, devido às suas propriedades estéticas e mecânicas. Em busca dessas propriedades, vários estudos analisaram a taxa de sobrevivência de restaurações zircônia-porcelana, relatando como uma das causas de falha a fratura precoce da porcelana de cobertura e o aumento significativo nos relatos clínicos de lascamento da porcelana de recobrimento aplicada sobre "coping" de zircônia. Diante desse problema, o objetivo deste trabalho foi determinar a tensão de falha no lascamento a partir de casos de clínicos e experimentais pertinentes a esse fenômeno em próteses fixas livres de metal .Foram coletados dados de artigos dos últimos 15 anos, por meio das bases de dados Pubmed e Google Schoolar, sendo selecionados para essa revisão os que obtiveram melhor abordagem do assunto, dando ênfase às possíveis causas de falhas nas restaurações cerâmicas dos casos clínicos e os ensaios realizados, visando um melhor entendimento desse fenômeno, via análise quantitativa e qualitativa, para melhor utilização e aproveitamento desse material na Odontologia. Para determinação da tensão de falha, foi empregada a mecânica da fratura linear elástica e determinado o fator de correção da trinca com base nas dimensões da trinca.Com a presente pesquisa, nota-se que amplitude de tensão influencia no processo de fratura, embora não tenha apontado exatamente para a causa da fratura. No entanto, pode-se inferir que uma baixa taxa de sobrevivência está relacionada a um grande defeito que, por sua vez, necessitou de uma sobrecarga para conduzir o processo de lascamento. Portanto, melhorias no processo de fabricação podem otimizar as características do material e sua aplicação final para suportar as tensões, a fim de aumentar a taxa de sobrevivência. / The introduction of zirconia in dentistry was due to the need for better mechanical properties of ceramic materials, because of an increasing aesthetic demand. Ceramics became widely used materials due to their aesthetic and mechanical properties. Aiming at these properties, several studies have analyzed the survival rate of zirconia-porcelain restorations, reporting as one of the causes of failure. Early porcelain fracture coverage and a significant increase in clinical reports of veneering porcelain applied over "coping "of zirconia. In view of this problem, the objective of this work was to determine the failure causes of chipping from clinical and experimental cases associated to this phenomenon in fixed metal free prostheses. Data from articles of the last 15 years were collected through the Pubmed and Google Schoolar databases. Those who obtained the best approach to the subject were selected for this analysis, emphasizing the possible causes of failures in the ceramic restorations of the clinical cases and the tests performed. Aiming for a better understanding of this phenomenon, via quantitative and qualitative analysis, to better use this material in dentistry. To determine the failure causes, linear elastic fracture mechanics were used and the crack correction factor was determined based on the crack dimensions. With the present research, it is noticed that stress amplitude influences in the fracture process, although it has not pointed exactly the cause of the fracture. However, it can be inferred that a low survival rate is related to a large defect, this in turn needed an overload to conduct the chipping process. Therefore, the manufacturing process can improve the characteristics of the material and its final application to withstand the stresses in order to increase the survival rate.
77

Quantifica??o de danos e crescimento de eucalipto em sistema de integra??o lavoura-pecu?ria-floresta

Barbosa, Demerson Luiz de Almeida 17 March 2017 (has links)
Submitted by Jos? Henrique Henrique (jose.neves@ufvjm.edu.br) on 2018-06-25T20:55:36Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) demerson_luiz_almeida_barbosa.pdf: 1831298 bytes, checksum: 82c8ae9507b56ac9f73a9ab0bb6fec79 (MD5) / Approved for entry into archive by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2018-07-18T12:37:53Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) demerson_luiz_almeida_barbosa.pdf: 1831298 bytes, checksum: 82c8ae9507b56ac9f73a9ab0bb6fec79 (MD5) / Made available in DSpace on 2018-07-18T12:37:54Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) demerson_luiz_almeida_barbosa.pdf: 1831298 bytes, checksum: 82c8ae9507b56ac9f73a9ab0bb6fec79 (MD5) Previous issue date: 2017 / Funda??o de Amparo ? Pesquisa do estado de Minas Gerais (FAPEMIG) / Os sistemas integrados de produ??o s?o uma possibilidade para otimiza??o do cultivo sustent?vel no semi?rido mineiro, principalmente em rela??o ?s ?reas de pastagens degradadas. Objetivou-se com esse trabalho analisar quantitativamente e qualitativamente o crescimento, a produ??o e o estoque de carbono (C) de dois gen?tipos de eucalipto em sistema de integra??o lavoura-pecu?ria-floresta (iLPF) implantado no norte de Minas Gerais. Essa pesquisa foi realizada na Fazenda da Barra, munic?pio de Francisco S?, entre dezembro de 2012 e novembro de 2016. Foi conduzida em ?rea experimental de 3,2 ha subdividida em dois tratamentos com Eucalyptus cloeziana e o h?brido urograndis. O sistema foi consorciado com sorgo e capim-marandu, com espa?amentos em renques duplos (2 x 3m) x 14 metros. Em cada tratamento foram estabelecidas 12 parcelas de 336 m2 distribu?das aleatoriamente, com inclus?o de 24 ?rvores/parcela. Foram avaliadas taxas de sobreviv?ncia, di?metro na altura do solo, di?metro na altura do peito e altura total das ?rvores, al?m de danos e debilidades. Tamb?m foram analisados volume, biomassa, fixa??o de C e sequestro de di?xido de C (CO2). Os dados foram submetidos ? an?lise de vari?ncia e de matriz de correla??o. Os resultados indicaram que a abelha arapu? e o cupim foram os principais fatores bi?ticos causadores dos danos e debilidades nos eucaliptos cloeziana e urograndis, respectivamente. O crescimento e volume dos gen?tipos foram estatisticamente diferentes para os 450, 630, 1.020 e 1.320 dias ap?s o transplantio. O urograndis, embora tenha apresentado menor taxa de sobreviv?ncia (66,7%), obteve maior volume (23,4920 m3 ha-1) e resist?ncia ao per?odo de seca. No entanto, o E. cloeziana apresentou maior taxa de sobreviv?ncia (80,6%) e menor volume (9,2974 m3 ha-1). Os incrementos correntes anuais para biomassa foram maiores no urograndis (5.673,36 kg ha-1) em rela??o ao cloeziana (3.166,04 kg ha-1). Dessa maneira, o eucalipto urograndis foi o gen?tipo que apresentou maior fixa??o de C (5,53 t ha-1) e sequestro de CO2 (20,30 t ha-1) no sistema de integra??o lavoura-pecu?ria-floresta avaliado. / Disserta??o (Mestrado) ? Programa de P?s-Gradua??o em Ci?ncia Florestal, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2017. / Integrated production systems are cited as a possibility for optimization of sustainable cultivation in the semi-arid region of Minas Gerais, especially in relation to degraded pasture areas. The objective of this work was to analyze quantitatively and qualitatively the growth, production and carbon stocks of two eucalyptus genotypes cultivated in an integrated crop-livestock-forest (ICLF) system in the north of Minas Gerais State, Brazil. This research was carried out at Fazenda da Barra, municipality of Francisco S?, between December 2012 and November 2016. It was conducted in a 3.2 ha experimental area subdivided into two treatments with Eucalyptus cloeziana and the urograndis hybrid. The system was intercropped with sorghum and marandu grass, with spacing in double rows (2 x 3m) x 14 m. In each treatment, 12 plots of 336 m2 were randomly distributed, including 24 trees/plot. Survival rates, diameter at soil height, diameter at breast height and total height of trees, as well as damage and weakness, were evaluated. Volumetric and biomass production, carbon (C) fixation and C dioxide sequestration (CO2) were also analyzed. Data were submitted to analysis of variance and correlation matrix. The results indicate that the ?arapu?? (Trigona spinipes) bee and the termite were the main biotic factors to the damages and weaknesses in eucalyptus cloeziana and urograndis, respectively. The growth and volumetric production of the genotypes were statistically different for the 450, 630, 1020 and 1,320 days after transplanting. Urograndis, although reaching the higher mortality rate (66.7%), had the higher volumetry production (23.4920 m3 ha-1) and resistance to the dry seasons. However, E. cloeziana had a higher survival rate (80.6%) and lower volumetric production (9.2974 m3 ha-1). The mean annual increment for biomass were higher in urograndis (5,673.36 kg ha-1) than in cloeziana (3,166.04 kg ha-1). Thus, eucalyptus urograndis was the genotype that presented higher C fixation (5.53 t ha-1) and CO2 sequestration (20.30 t ha-1) in the ICLF system evaluated.
78

[en] EXTREME VALUE THEORY: VALUE AT RISK FOR FIXED-INCOME ASSETS / [pt] TEORIA DOS VALORES EXTREMOS: VALOR EM RISCO PARA ATIVOS DE RENDA-FIXA

RENATO RANGEL LEAL DE CARVALHO 03 May 2006 (has links)
[pt] A partir da década de 90, a metodologia Value at Risk (VaR) se difundiu pelo mundo, tanto em instituições financeiras quanto em não financeiras, como uma boa prática de mensuração de riscos. Em geral, abordagens paramétricas são muito utilizadas pelo mercado, apesar de freqüentemente não levarem em conta uma característica muito encontrada nas distribuições dos retornos de ativos financeiros: a presença de caudas pesadas. Uma abordagem baseada na Teoria dos Valores Extremos (TVE) é uma boa solução quando se deseja modelar caudas de distribuições probabilísticas que possuem tal característica. Em contra partida, poucos são os trabalhos que procuram desenvolver a TVE aplicada a ativos de renda-fixa. Com base nisto, este estudo propõe uma abordagem de simples implementação de cálculo de VaR para ativos de renda-fixa baseado na Teoria dos Valores Extremos. / [en] Since the 90 decade, the use of Value at Risk (VaR) methodology has been disseminated among both financial and non-financial institutions around the world, as a good practice in terms of risks management. In spite of the fact that it does not take into account one of the most important characteristics of financial assets returns distribution - fat tails (excess of kurtosis), the parametric approach is the most used method for Value at Risk measurement. The Extreme Value Theory (EVT) is an alternative method that could be used to avoid the underestimation of Value at Risk, properly modeling the characteristics of probability distribution tails. However, there are few works that applied EVT to fixed-income market. Based on that, this study implements a simple approach to VaR calculation, in which the Extreme Value Theory is applied to fixed-income assets.
79

Um balanço do processo de privatização do sistema de telefonia fixa e móvel no Brasil

Althaus Junior, Adalto Acir January 2002 (has links)
O presente trabalho objetiva identificar a influência das privatizações na evolução do sistema de telefonia fixa e móvel celular brasileiro. O estudo foi desenvolvido avaliando-se um período de três anos pré-privatização versus pós-privatização, desconsiderando-se o ano em que ocorreu a troca do controle acionário das companhias. Para a execução do estudo, utilizou-se duas amostras distintas, uma para cada período, que representavam parcelas semelhantes da receita total do mercado para os respectivos períodos antes e pós-privatização. De modo a atingir o objetivo central do trabalho, desenvolveu-se o tema em quatro aspectos: desempenho das empresas de telefonia, qualidade e universalização dos serviços de telefonia, geração de divisas para o governo pelas empresas de telefonia e variação nos preços dos serviços de telefonia fixa. Para operacionalizar a análise, utilizou-se um conjunto de indicadores para cada um dos aspectos abordados e aplicou-se, primeiramente, o teste não-paramétrico de Kolmogorov- Smirnov. Em seguida, constatou-se que a forma de distribuição dos dados, antes desconhecida, atendia aos pressupostos dos testes paramétricos e aplicou-se, também, aos conjuntos de indicadores o teste t de Student de modo a perceber diferenças mais sutis principalmente nos casos em que o primeiro teste não detectou diferenças significativas. A avaliação geral dos resultados tende a rejeitar a hipótese nula de que a privatização das empresas de telefonia não reverteu em ganhos para o Estado e a população em geral. Esta conclusão baseia-se na análise dos quatro conjuntos de indicadores que apresentaram as seguintes evidências: em geral, a maioria dos indicadores de desempenho das empresas sinalizam uma queda em sua performance entre antes e depois das privatizações; a análise dos indicadores de qualidade e universalização dos serviços apresentaram sensível melhora, evidenciando uma evolução em termos de qualidade e de popularização dos serviços de telefonia; os indicadores de geração de divisas para o Estado apresentaram um crescimento no montante absoluto arrecadado, mas sem um aumento significativo na proporção da carga tributária incidente; a análise da evolução dos preços dos serviços de telefonia fixa revela que, considerando-se os efeitos inflacionários, houve uma redução destes preços no período pós-privatização comparando-se com o período pré-privatização.
80

Can search costs explain price differentiation in the Brazilian fund industry?: replicating Hortaçsu & Syverson (2004)

Soares, Paulo Sergio de Miranda da Costa 31 March 2017 (has links)
Submitted by Paulo Sergio Soares (ps-soares@hotmail.com) on 2017-06-05T19:51:17Z No. of bitstreams: 1 Dissertação_Final.pdf: 620762 bytes, checksum: 4b6198b156d7085162e70f3152b74284 (MD5) / Approved for entry into archive by GILSON ROCHA MIRANDA (gilson.miranda@fgv.br) on 2017-06-06T13:11:24Z (GMT) No. of bitstreams: 1 Dissertação_Final.pdf: 620762 bytes, checksum: 4b6198b156d7085162e70f3152b74284 (MD5) / Made available in DSpace on 2017-06-22T12:45:10Z (GMT). No. of bitstreams: 1 Dissertação_Final.pdf: 620762 bytes, checksum: 4b6198b156d7085162e70f3152b74284 (MD5) Previous issue date: 2017-03-31 / This work replicates Horta¸csu & Syverson (2004) model using Brazilian data. The objective of this paper is to evaluate if search frictions explain price dispersion, administrative fees, in the Brazilian funds industry. We use in our sample passive funds targeting two market indexes: Ibovespa and IRF-M. We found evidence that search costs are higher in the Ibovespa market than the IRF-M market. Considering those funds as differentiated products we observe that the Management Company plays an important role in consumers evaluation. / Este trabalho replica o trabalho de Hotaçsu e Syverson (2004) utilizando dados brasileiros. O objetivo deste trabalho é avaliar se fricções de busca explicam dispersão de preços, taxas de administração, na industria de fundos brasileira. Nos utilizamos em nossa amostra fundos passivos que tentam replicar dois índices: o Ibovespa e o IRF-M. Nos encontramos evidência que custos de busca são maiores em no mercado de fundos Ibovespa. Considerando estes fundos como produtos diferenciados observamos que as empresas gestoras têm um papel importante nas preferências dos consumidores.

Page generated in 0.0904 seconds