• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 68
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 69
  • 69
  • 65
  • 37
  • 33
  • 30
  • 17
  • 16
  • 15
  • 13
  • 10
  • 10
  • 10
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Estudo mecânico comparativo da estabilização de fratura ilíaca com dois tipos de implantes (parafusos com placa de compressão dinâmica e parafusos associados ao polimetilmetacrilato) em hemipelves caninas sintéticas

Prada, Tiago Carmagnani [UNESP] 24 February 2015 (has links) (PDF)
Made available in DSpace on 2015-08-20T17:09:46Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-02-24. Added 1 bitstream(s) on 2015-08-20T17:26:26Z : No. of bitstreams: 1 000835505.pdf: 765609 bytes, checksum: c2d6333de2a901979de6850158d1e391 (MD5) / As fraturas da pelve correspondem a 20-30% das fraturas encontradas nos cães e, geralmente são ocasionadas por trauma de grande intensidade na região caudal do animal. Nos casos onde há fraturas completas, principalmente com desvio ósseo, o tratamento cirúrgico é recomendado. O estudo mecânico das técnicas cirúrgicas que podemos utilizar é de extrema importância para avaliação da melhor maneira de tratamento destas lesões. O objetivo deste estudo foi comparar, do ponto de vista biomecânico, a fixação das fraturas do ílio utilizando placa de compressão dinâmica ou parafusos associados ao polimetilmetacrilato através de um teste estático. Foram utilizadas 16 pelves caninas de origem sintética, nas quais uma osteotomia transversa foi realizada no corpo do ílio. As fixações foram divididas em dois grupos: fixação com placa de compressão dinâmica e parafusos ou parafusos associados ao polimetilmetacrilato. Posteriormente à fixação com os implantes foi aplicada uma carga no acetábulo de cada corpo de prova até a falha. A estabilização com o polimetilmetacrilato mostrou ser mais resistente, pois resistiu a uma maior quantidade de carga em relação à placa de compressão dinâmica em todos os corpos de prova / Pelvic fractures correspond 20 to 30 % of the fractures observed in dogs. They are usually caused by trauma in the posterior region. Complete fractures, especially with bone axis deviation should be surgically treated. The mechanical study of surgical techniques that we can use is very important to evaluate the best way to treat these fractures. The aim of this study was to compare, biomechanically, the use of a dynamic compression plate or screws and polymethylmethacrylate to stabilize a ilial body fracture using a static test. Sixteen canine synthetic pelvis (test specimens) with a transverse osteotomy of the ilial body were used. After the fixation with the implants a load to the acetabulum was applied until fail. The stabilization with polymethylmethacrylate was stronger than dynamic compression plate, resisting to a greater amount of charge in all test specimens
32

Osteossíntese minimamente invasiva com placa bloqueada nas fraturas de tíbia em cães

Rosa-Ballaben, Nátalie Massaro [UNESP] 27 June 2014 (has links) (PDF)
Made available in DSpace on 2014-11-10T11:09:44Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-06-27Bitstream added on 2014-11-10T11:58:34Z : No. of bitstreams: 1 000790811.pdf: 1696564 bytes, checksum: 027b168593fdf7d048ba6f9ee1d8823d (MD5) / Avanços na compreensão da biologia óssea e das complicações das fraturas têm levado a modificações na abordagem da fixação interna das mesmas, sendo a osteossíntese minimamente invasiva com placa (MIPO) uma das mais recentes evoluções para o manejo biológico das fraturas. O objetivo do presente estudo foi avaliar o uso de placas bloqueadas aplicadas de forma minimante invasiva em fraturas de tíbia de cães. Foram utilizados 10 cães apresentando fraturas de tíbia, de idades e raças variadas. Os animais foram avaliados quanto a deambulação, intensidade do edema, exames radiográficos, e densitometria óptica nos períodos 0, 15, 30, 60, 90 e 120 dias de pós-operatório. Após 15 dias de pós-operatório 80% dos cães já utilizavam o membro ao caminhar e apresentavam formação de edema leve a ausente no membro operado. Após 30 dias de pós-operatório 100% dos cães já apoiavam o membro ao caminhar e não apresentavam formação de edema no membro. Todos os pacientes apresentaram sinais radiográficos e densitométricos de início de consolidação óssea após 15 dias de pós-operatório. O tratamento de fraturas de tíbia por meio da MIPO é uma alternativa eficaz, resultando em utilização precoce do membro e união clínica efetiva, e pode ser realizada sem uso de intensificadores de imagem / Advances in the comprehension of the bone healing and complications of the treatment of the fractures have been changed some concepts. Less invasive procedures have been advocated. A minimally invasive plate osteosynthesis (MIPO) is one of the best ways to avoid over tissue damage. The aim of this study was to evaluate the use of MIPO in tibial fractures in dogs. Ten dogs presenting a tibial fracture were used. Deambulation, swelling intensity and radiographic changes were evaluated preoperatively, just after the procedure and at 15, 30, 60, 90 e 120 days postoperatively. Six of 10 (60%) dogs were able to walk at 15 days postoperatively with slight swelling and mild lameness. Two of 10 (20%) presented normal walking at the same period. At 30 days postoperatively all dogs were able to walk normally. Six of them were not lame and 9 did not present swelling. Bone healing could be followed by radiographic evaluation. All dog presented initial radiographic signs of bone healing after 15 days postoperatively. Two of 10 showed clinical union at this time. In five of 10 (50%) clinical union could be observed after 60 days. The treatment of tibial fractures by MIPO is an effective alternative resulting in early and effective clinical union and can be performed without the use of image intensifiers
33

Avaliação do comportamento mecânico de três diferentes tipos de osteossíntese em fratura de côndilo mandibular: análise por elementos finitos 3D

Jesus, Giorge Pessoa de [UNESP] 27 September 2013 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-09-27Bitstream added on 2014-12-02T11:21:07Z : No. of bitstreams: 1 000794326.pdf: 1135127 bytes, checksum: cb4342f5f8184e0cb349451bdf351409 (MD5) / O uso de duas miniplacas retas é o método mais indicado na literatura, para se prevenir complicações no tratamento de fraturas de côndilo. Diferentes estudos evidenciam que a estabilidade da osteossíntese é relacionada com as tensões mecânicas que ocorrem na região do côndilo, geradas pelos músculos da mastigação. O objetivo neste estudo foi avaliar o comportamento mecânico de três métodos de osteossíntese, por meio de um modelo mandibular de elementos finitos (MEF), comparando a distribuição de tensões e o comportamento dos materiais nas fraturas subcondilares baixas. Simulou-se uma fratura transversa subcondilar baixa, no modelo mandibular e a adaptação dos materiais de osteossíntese para a fixação da fratura. Três métodos de fixação com placas de titânio foram testados: 1) duas placas retas; 2) uma placa lambda e 3) uma placa trapezoidal. Os resultados mostraram que os métodos de osteossíntese proporcionam uma boa rigidez ao sistema de fixação, com pouco deslocamento na linha de fratura. Apesar disto, com a intensidade da força aplicada, todos os modelos estariam sujeitos a falhas, pois apresentaram valores de tensão de von Mises muito elevados. Comparando o desempenho dos três modelos de placas testados, observou-se que, a placa lambda se comportou melhor, havendo uma distribuição das tensões de von Mises sobre o material de fixação e tensão máxima principal sobre o osso mais homogênea. / The use of two straight plates is the most indicated in literature, to prevent the subcondilar fractures complications. Different studies have highlighted that the osteosynthesis stability is related to the mechanical stresses that occur in the region of the condyle, generated by the chewing muscles. This study evaluated the biomechanical behavior of three methods of fixation, through a mandibular finite element model (FEM), comparing the stress distribution and behavior of materials in low subcondilar fractures. A transverse fracture was simulated in the mandibular model and on adapting osteosynthesis materials for fracture fixation. Three methods of fixations using titanium plates were tested: two straight plates; one lambda plate and; one trapezoidal plate. The results showed that the method of osteosynthesis provides a good stiffness on the fixation system with little displacement at the fracture line. Nevertheless, by the intensity of the applied force, all models would be subject to failure, because they presented very high stress values. Comparing the performance of the three plate’s models tested, it was observed better behaviors for the lambda plate, with a more homogeneous distribution of von Mises stresses on the osteosynthesis devices and maximum principal strain over the bone.
34

Caracterização fenotípica e genotípica de bactérias recuperadas de implante ortopédico de conjunto placa-parafuso e parafuso de aço inoxidável austenítico após remoção cirúrgica

Santos, Cássio Antonio Lanfredi dos [UNESP] 29 August 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:20Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-08-29Bitstream added on 2014-06-13T20:56:14Z : No. of bitstreams: 1 santos_cal_me_arafcf_parcial.pdf: 117464 bytes, checksum: 13283cebdcbc3d9085c0801450c381fd (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Universidade Estadual Paulista (UNESP) / A maioria dos casos de fraturas ósseas é utilizada nas cirurgias, implantes ortopédicos de osteossíntese (placa-parafuso e parafusos) confeccionados em aço inoxidável austeníticos, devido à sua baixa relação custo-benefício. As infecções associadas aos implantes de osteossintese estão relacionadas com o crescimento de microrganismos em biofilmes, resultando em um processo infeccioso de difícil erradicação. O objetivo do estudo foi identificar os microrganismos recuperados do conjunto metálico placaparafuso e parafusos após remoção cirúrgica, avaliar a capacidade de aderência dos microrganismos, verificar a viabilidade celular, caracterizar genotipicamente os isolados Gram-positivos e detectar a resistência aos antimicrobianos. Os conjuntos placa-parafuso e parafusos de aço inoxidável austenítico ASTM F138/F139 e ISO NBR 5832-1/9 foram transportados em bolsa de polietileno para o Laboratório de Microbiologia Clínica. Os implantes foram lavados em solução tampão fosfato-salino, armazenados em bolsa contendo solução Ringer e submetidos ao banho ultrassônico em freqüência de 40±2 kHz por 5 minutos. O fluido sonicado foi transferido para tubos Falcon e centrifugado a 3.000g durante 20 minutos. O sedimento foi resuspendido em nova solução Ringer, homogeneizado por vortex e 10μL semeados em ágar Sangue de carneiro 5%, MacConkey e Sabouraud. Os meios foram incubados em diferentes condições de temperatura por 7 a 14 dias para recuperação de microrganismos. O perfil de resistência dos isolados foi obtido de acordo com CLSI 2011. Para análise da viabilidade celular foi utilizado o kit Live/Dead e microscópio de fluorescência... / The majority of cases of bone fractures is used in surgery, internal fixation of orthopedic implants (screw-plate and screws) manufactured in austenitic stainless steel due to its low cost-benefit. Infections associated with implant fixation are related to the growth of microorganisms in biofilms, resulting in an infection difficult to eradicate. The objective of study was to identify the microorganisms recovered from the set screwplate and screws metallic after surgical removal, evaluate the capacity of adherence of microorganisms, check the cell viability and characterize the isolates genotypically Gram-positive and detect antimicrobial resistance. The sets screw-plate and screws of austenitic stainless steel ASTM F138/F139 and ISO NBR 5832-1/9 were transported in polyethylene bag to the Laboratory of Clinical Microbiology. The implants were washed in phosphate buffered saline solution, stored in bags containing Ringer's solution and submitted to ultrasonic bath at a frequency of 40 kHz ± 2 for 5 minutes. The sonicate fluid was transferred to falcon tubes and centrifuged at 3.000g for 20 minutes The new sediment was re-suspended in Ringer's solution, homogenized by vortex and 10μL seeded agar 5% sheep blood, MacConkey and Sabouraud. The media were incubated at different temperatures for up to 7 days for growth of CFU mL-1. The resistance profile of the isolates was obtained according to CLSI 2011. For analysis of cell viability kit was used for Live/Dead and fluorescence microscope. After microbiological analysis the isolation was observed in some samples of polymicrobial implants. The data obtained showed that bacteria were the most isolated coagulase-negative... (Complete abstract click electronic access below)
35

Avaliação do seio maxilar após fratura do complexo zigomático-maxilar tratado com fixação interna rígida em dois pontos: estudo radiográfico em humanos

Kayatt, Fernando Esgaib [UNESP] 06 August 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:41Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-08-06Bitstream added on 2014-06-13T19:50:41Z : No. of bitstreams: 1 kayatt_fe_me_araca.pdf: 1754439 bytes, checksum: e4d89ad0bd72df4dc5b0274e0a5e3695 (MD5) / O complexo zigomático maxilar é a segunda área da face mais atingida por injúrias, superada apenas pelos ossos nasais. É elemento essencial na configuração da face, uma vez que é a principal estrutura formadora do terço médio facial. É importante na biomecânica, está situado entre o víscero e o neurocrânio, desempenha papel fundamental na absorção e escoamento das forças de mastigação através dos pilares de reforço e sustentação. Nesse contesto encontra-se o seio maxilar cujas funções destacamse: diminuição do peso do crânio; auxiliar a ressonância da voz, a produção e a armazenagem do muco, a umidificação do ar inspirado, a manutenção do aquecimento da fossa nasal, servir como acessório do olfato, definir o contorno facial, entre outras. Avaliamos, através de radiografias PA de Waters, 40 pacientes, sendo 20 pacientes traumatizados nessa região, que foram submetidos à fixação interna rígida em dois pontos e 20 pacientes hígidos, comparando a projeção da imagem do contorno do seio maxilar. Estas avaliações foram realizadas em um período pós-operatório superior a 6 meses. Após análise dos resultados, concluímos que baseado nos achados radiográficos e nos valores de áreas dos seios maxilares, a fixação interna rígida em dois pontos mostrou-se eficaz no tratamento das fraturas não cominutivas do complexo zigomáticomaxilar. / The ZMC is the second facial area most affected by injuries, only surpassed by nasal bones fractures. It’s an essential element in facial configuration because it’s the middle third facial main structure. It’s important biomechanical being situated between the visceral and neurocranium, develop fundamental absorving and draining of the chewing forces job, across the sustaintation and strenghten pillars. Inside this complex the maxillary sinus and its functions are: to reduce head weight, to help voice ressonance, to produce and to store mucus, to umidificate the breathen air, to maintain the nasal fossa warm, olfative accessory and to define the facial contour and others. The research was performed through PA Waters radiography; 40 patients: 20 traumatizated patients in this region, submitted to the two points IRF and 20 health patients were evaluated, comparing the image projection of the maxillary sinus and observating the stability of this kind of fixation. These evaluations were made in post-operative periods, latter 6 months. After result analysis we concluded, based radiography evidence and measurement maxillary sinus area, the two points IRF are efficient on treatment of ZMC fractures not cominutive.
36

Osteossíntese de tíbia com uso de fixador esquelético externo conectado ao pino intramedular "tie-in" em cães /

Dias, Luis Gustavo Gosuen Gonçalves. January 2006 (has links)
Orientador: João Guilherme Padilha Filho / Banca: Júlio Carlos Canola / Banca: Jorge Luiz Oliveira Costa / Resumo: A incidência de fratura de tíbia em cães representa 21% das que ocorrem nos ossos longos. Vários métodos são utilizados nas osteossínteses deste osso, tais como: pinos intramedulares; fixadores esqueléticos externos; placas ósseas e; associações entre eles. O método usado foi uma modificação da configuração denominada "tie-in", na qual um PIM é conectado externamente a pinos de Schanz ou parafusos de aço inoxidável fixados com metil-metacrilato. O PIM é introduzido através de um orifício confeccionado na face medial da tíbia, próximo à crista tibia!. A configuração foi utilizada em 21 cães com fratura de tíbia atendidos no Hospital Veterinário do Câmpus da UNESP de Jaboticabal-SP. Os animais foram avaliados clínica e" radiograficamente, no período pré e pós-operatório imediato e a cada 30 dias, até completar quatro meses. Os animais recuperaram, clinicamente, a função do membro no período médio de 11 dias após a cirurgia. Nove animais tiveram a configuração dinamizada, por meio da desconexão do PIM; remoção do PIM ou dos implantes de fixação e retirada dos implantes de fixação e manutenção do PIM. Radiograficamente verificou-se consolidação óssea em média de 76 dias de pós operatório, e apenas um animal apresentou não-união. A configuração "tie-in" mostrou se eficaz como método de osteossíntese em fraturas tibiais de cães. / Abstract: The incidence of tibial fractures in dogs assumes 21 % of ali fractures that occur in long bones. Several methods are used in the osteosynthesis, of these fractures like external skeletal fixator, bone plates and associated techniques. The aim of this study is to describe the method and perform a radiographic and clinical evaluation of a group of 21 dogs with tibial fractures from the veterinary teaching hospital of the UNESP SÃO PAULO STATE UNIVERSITY- CAMPUS OF JABOTICABAL. The used method was a modification of the termed "tie-in" configuration, in that an IMP was connected externally with Schanz pins or stainless steel screws fixed together with methylmethacrylat. The pin was applied through hole on the medial tibia near the tibial crest. Clinical and radiographic evaluations were performed in pre-and post-operatory period and at 30, 60, 90 and 120 days. Animais recovered the function of the affected limb in a mean period of 11 days afier the surgery. Nine dogs underwent dynamization through: a) IMP disconnection, b) IMP or, c) fixation pins takeout and d) fixation pins takeout and maintenance of the IMP. Radiographicaly, the fracture union occurred in 20 dogs, in a mean period of 76 days; non-union was observed in only one dog. T~erefore, the "tie-in" modificated frame configuration showed efficacy as a method of osteosynthesis in tibial fractures of dogs. / Mestre
37

Estudo mecânico comparativo da estabilização de fratura ilíaca com dois tipos de implantes (parafusos com placa de compressão dinâmica e parafusos associados ao polimetilmetacrilato) em hemipelves caninas sintéticas /

Prada, Tiago Carmagnani. January 2015 (has links)
Orientador: Bruno Watanabe Minto / Banca: Luis Gustavo Gosuen Gonçalves Dias / Banca: Sheila Canevese Rahal / Resumo: As fraturas da pelve correspondem a 20-30% das fraturas encontradas nos cães e, geralmente são ocasionadas por trauma de grande intensidade na região caudal do animal. Nos casos onde há fraturas completas, principalmente com desvio ósseo, o tratamento cirúrgico é recomendado. O estudo mecânico das técnicas cirúrgicas que podemos utilizar é de extrema importância para avaliação da melhor maneira de tratamento destas lesões. O objetivo deste estudo foi comparar, do ponto de vista biomecânico, a fixação das fraturas do ílio utilizando placa de compressão dinâmica ou parafusos associados ao polimetilmetacrilato através de um teste estático. Foram utilizadas 16 pelves caninas de origem sintética, nas quais uma osteotomia transversa foi realizada no corpo do ílio. As fixações foram divididas em dois grupos: fixação com placa de compressão dinâmica e parafusos ou parafusos associados ao polimetilmetacrilato. Posteriormente à fixação com os implantes foi aplicada uma carga no acetábulo de cada corpo de prova até a falha. A estabilização com o polimetilmetacrilato mostrou ser mais resistente, pois resistiu a uma maior quantidade de carga em relação à placa de compressão dinâmica em todos os corpos de prova / Abstract: Pelvic fractures correspond 20 to 30 % of the fractures observed in dogs. They are usually caused by trauma in the posterior region. Complete fractures, especially with bone axis deviation should be surgically treated. The mechanical study of surgical techniques that we can use is very important to evaluate the best way to treat these fractures. The aim of this study was to compare, biomechanically, the use of a dynamic compression plate or screws and polymethylmethacrylate to stabilize a ilial body fracture using a static test. Sixteen canine synthetic pelvis (test specimens) with a transverse osteotomy of the ilial body were used. After the fixation with the implants a load to the acetabulum was applied until fail. The stabilization with polymethylmethacrylate was stronger than dynamic compression plate, resisting to a greater amount of charge in all test specimens / Mestre
38

Estudo comparativo do Titânio versus Polímero vegetal para fixação interna rígida de fraturas orbitárias de coelhos /

Nunes, Elifas Levy. January 2006 (has links)
Orientador: Silvana Artioli Schellini / Banca: Claudia Helena Pellizon / Banca: Jair Cortez Montovani / Banca: Antonio Carlos Neder / Banca: Suzana Matayoshi / Resumo: Nas últimas décadas, os materiais utilizados para reparações ósseas de estruturas faciais tiveram um aprimoramento que muito facilitou a fixação interna rígida. Entretanto, este campo permanece aberto para as pesquisas até os dias atuais, uma vez que não se tem ainda o material ideal para este fim. Objetivo: avaliar a reparação de fraturas da parede orbitária usando a fixação interna rígida com miniplacas de titânio e de polímero vegetal comparando-as. Material e método: foi realizado um estudo experimental, prospectivo, na Faculdade de Medicina de Botucatu, no qual foram utilizados 45 coelhos albinos, submetidos a fratura do assoalho da órbita e divididos em três grupos especiais... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In the last few decades, the advances in material used for repairing facil bone fractures have greatly improved internal rigid fixing. However research in this area remains open as there still no ideal material. Objective: to evaluate the repair of orbital wall fractures with internal rigid fixings comparing mini titanium and reabsorbable vegetal polymer plates... (Complete abstract, click eletronic address below) / Doutor
39

Tratamento cirúrgico intrabucal das fraturas de ângulo mandibular com uma miniplaca de titânio : estudo clínico e radiográfico /

Érnica, Natasha Magro. January 2002 (has links)
Orientador: Idelmo Rangel Garcia Júnior / Banca: Cássio Edvard Sverzut / Banca: Wilson Roberto Poi / Resumo: O objetivo deste estudo foi avaliar, clínica e radiograficamente, pacientes com fraturas de ângulo mandibular tratadas por meio de redução cirúrgica e fixação com uma miniplaca de titânio de 2,0 mm de espessura, associada a parafusos monocorticais. Foram avaliados retrospectivamente 21 pacientes, com 22 fraturas fraturas de ângulo mandibular, tratados pela equipe de Cirurgia e Traumatologia Buco-Maxilo- Facial da Faculdade de Odontologia de Araçatuba - UNESP, na Santa Casa de Misericórdia de Araçatuba e Santa Casa de Misericórdia de Birigüi, Estado de São Paulo, no período de julho de 1999 a fevereiro de 2002. Todas as fraturas de ângulo mandibular avaliadas foram fixadas utilizando uma miniplaca de 2,0 mm de espessura, com parafusos monocorticais, disposta ao longo da linha oblíqua mandibular, sem utilização de fixação intermaxilar no pós-operatório. O tempo de proservação variou de 6 a 44 meses, com média de 15 meses e 1 dia. Foi observada, para essas fraturas, incidência de 14,3% de complicações pós-operatórias, sendo 4,8% infecção, 4,8% má-oclusão e 4,8% distúrbios sensoriais - hiperestesia no local de retenção da miniplaca. Dentre as complicações, a única que exigiu nova intervenção cirúrgica sob anestesia local foi a infecção pós-operatória. Assim, pode-se concluir que o método empregado foi clinicamente adequado para o tratamento de fraturas simples de ângulo mandibular, a presença de apenas uma miniplaca não interferiu no índice de complicações pós-operatórias, e o método evitou a fixação intermaxilar pós- operatória. / Abstract: The aim of this study was to evaluate clinical and radiographic, mandibular angle fractures treated by open reduction and one single 2.0 mm titanium miniplate fixation associated with monocortical screws. The author retrospectively evaluated 21 patients, with 22 mandibular angle fractures, operated by Oral and Maxillofacial Surgery Division from the Dental School of Araçatuba, UNESP, Brazil, during the period from July 1999 to February 2002. All mandibular angle fractures studied were treated by open reduction and internal fixation with one single 2.0 mm miniplate, positioned along the mandible oblique line, without post-operative intermaxilar fixation. Follow-up ranged from 6 to 44 months, with a mean of 15 months and 1 day. Complications occurred in 3 patients (14,3%). One patient (4,8%) presented post-operative infection, one (4,8%) malocclusion, and one (4,8%) sensory disturbance - hyperesthesia in the region of the retained miniplate. The only case requiring a further surgical intervention under general anesthesia was the infection case. Thus, results allowed to conclude that the fixation method was suitable for treatment of simple mandibular angle fractures, the presence of only one single miniplate did not interfere on the post-operative complication rate, and the method avoided post-operative intermaxilar fixation. / Mestre
40

Caracterização físico-química, morfológica, análise mecânica e de elementos finitos 3D, de diferentes placas e parafusos metálicos e técnicas de fixação interna, empregadas em fraturas de ângulo mandibular /

Guastaldi, Fernando Pozzi Semeghini. January 2013 (has links)
Orientador: Eduardo Hochuli Vieira / Banca: Sérgio Alexandre Gehrke / Banca: Eduardo Sanches Gonçales / Banca: Idelmo Rangel Garcia Junior / Banca: Luis Geraldo Vaz / Resumo: Proposição: Realizar uma caracterização físico-química, morfológica e comparar o comportamento mecânico de uma liga experimental de Ti-Mo, ao sistema de fixação análogo à base de Ti, em fraturas de ângulo mandibular, favoráveis ao deslocamento. Adicionalmente, análises de elementos finitos 3D foram realizadas para avaliar o padrão de distribuição de tensões nas placas e nos parafusos. Material e Método: Vinte e oito réplicas de mandίbulas de poliuretano foram usadas e uniformemente seccionadas na região do ângulo mandibular esquerdo. Estas foram divididas em 4 grupos considerando o material das placas e as técnicas de fixação interna: grupo Eng 1P, uma placa (zona de tensão da mandίbula) e 4 parafusos de 6 mm de comprimento; grupo Eng 2P, duas placas (uma na zona de tensão da mandίbula e a outra na zona de compressão), a primeira fixada com 4 parafusos de 6 mm de comprimento e a segunda com 4 parafusos de 12 mm de comprimento, sendo todo o material de fixação do sistema 2.0-mm. Os mesmos grupos foram criados para a liga Ti-15Mo. Cada grupo foi submetido a uma carga vertical linear no primeiro molar. As médias e os desvios-padrão foram comparados para avaliação estatίstica (ANOVA; p < .05). Adicionalmente, foi construído um modelo de elementos finitos 3D considerando as mesmas variáveis para avaliar as tensões equivalentes de von Mises (σvM) nas placas e nos parafusos. Resultados: Diferença estatisticamente significativa (p < .05) foi encontrada quando foi realizada a comparação entre ambas as técnicas de fixação (1 e 2 placas), independentemente do material das placas (cpTi and Ti-15Mo). Quando considerado os valores das tensões equivalentes de von Mises (σvM) para... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Purpose: Perform a physico-chemical and morphological characterization and compare the mechanical behavior of an experimental Ti-Mo alloy to the analogous metallic Ti-based fixation system, for mandibular angle fractures, favorable to displacement. Additionally, finite element analysis was performed to assess the stress distribution in the plates and screws. Material and Method: Twenty eight polyurethane mandible replicas were used and uniformly sectioned on the left mandibular angle. These were divided into 4 groups considering the material of the plates and the internal fixation techniques: group Eng 1P, one 2.0-mm plate (tension zone of the mandible) and 4 screws 6 mm long; group Eng 2P, two 2.0-mm plates (one in the tension zone of the mandible and the other in the compression zone), the first fixed with 4 screws 6 mm long and the second with 4 screws 12 mm long. The same groups were created for the titanium alloy (Ti-15Mo). Each group was subjected to linear vertical loading at the first molar. Means and standard deviations were compared with respect to statistical significance (ANOVA; p < .05). Additionally, an three-dimensional finite element model reproducing the characteristics of the specimens used in the mechanical tests were created to evaluate the von Mises equivalent stress (σvM) in the plates and screws. Results: Statistically significant difference (p < .05) was found when the comparison between both internal fixation techniques (1 and 2 plates) was performed, regardless the materials of the plates (cpTi and Ti-15Mo). When considering the von Mises equivalent stress (σvM) values for the comparison between both groups (Eng and Ti-15Mo) with 1 plate, an decrease of 10.5% in the plate and an decrease of 29.0% in the screws... (Complete abstract click electronic access below) / Doutor

Page generated in 0.0751 seconds