• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 176
  • 15
  • 12
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 211
  • 138
  • 29
  • 23
  • 23
  • 22
  • 18
  • 18
  • 17
  • 16
  • 16
  • 15
  • 13
  • 13
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Avaliação da resistência da união de sistemas adesivos após a aplicação de agentes dessensibilizantes em dentina humana / Bond strength evaluation of the adhesive systems after desensitizer agents in human dentin

Teixeira, Vitória Celeste Fernandes 08 July 2011 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-07-13T13:13:18Z No. of bitstreams: 1 vitoriacelestefernandesteixeira.pdf: 5962558 bytes, checksum: 288c2013154e288680445ffcde39df0c (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-13T16:54:59Z (GMT) No. of bitstreams: 1 vitoriacelestefernandesteixeira.pdf: 5962558 bytes, checksum: 288c2013154e288680445ffcde39df0c (MD5) / Made available in DSpace on 2016-07-13T16:54:59Z (GMT). No. of bitstreams: 1 vitoriacelestefernandesteixeira.pdf: 5962558 bytes, checksum: 288c2013154e288680445ffcde39df0c (MD5) Previous issue date: 2011-07-08 / O objetivo do presente estudo foi avaliar a resistência da união à microtração dos sistemas adesivos convencional (Single Bond II, SB) e autocondicionante (Clearfil SE Bond, SE) em dentina humana condicionada após a aplicação de agentes dessensibilizantes. Foram utilizados discos obtidos de terceiros molares humanos hígidos, os quais tiveram o esmalte oclusal removido para exposição de superfícies planas de dentina média. Seis grupos foram formados, de acordo com os materiais utilizados: G1 (controle) – hibridização com SB; G2 - dessensibilizante à base de oxalato (BisBlock, BB) e SB; G3 - dessensibilizante à base de fluoreto (Aqua Prep F, AF) e SB; G4 (controle) – hibridização com SE; G5 – BB e SE; G6 – AF e SE. Sobre estas superfícies foram confeccionados blocos de resina composta Filtek Z350 de 5 mm de altura para obtenção de palitos de 1Ox1x1mm. Os corpos de prova foram armazenados em água deionizada a 37° por 24h e submetidos ao ensaio mecânico de microtração com velocidade de 1mm/min até a fratura. Os resultados foram analisados através de ANOVA two-way e Teste Tukey (p<0,05). Os valores médios dos grupos em MPa foram: G2 46,48 (8,04), G3 44,87 (11,26), G5 39,02 (13,45), G4 36,95 (7,14), G1 36,66 (10,84) e G6 32,71 (13,83) os quais não exibiram diferença estatisticamente significativa entre si (p=0,012). Conclui-se que o uso combinado de dessensibilizantes aos sistemas adesivos convencional e autocondicionante sobre a dentina humana condicionada não alterou a resistência da união. / The aim of study was evaluate the microtensile bond strength of the total etch (Single Bond II, SB) and self-etch adhesive systems (Clearfil SE Bond, SE) in human dentin after desensitizer agents. Disks were obtained from human third molars, which had their oclusal enamel removed to expose flat dentin surface. Six groups were formed according to the materials used: G1 (control)- hybridization with SB, G2- oxalate desensitizer (BisBlock, BB) and SB, G3- fluoride desensitizer (Aqua Prep F, AF) and SB, G4 (control)- hybridization with SE, G5- BB and SE, G6- AF and SE. On these surfaces were made blocks of composite Filtek Z350 of 5 mm to obtain “sticks” 10x1x1 mm. The specimens were stored in deionized water at 37°/ 24 h and subjected to microtensile testing 1 mm/min until fracture. The images were observed in MEV. The results were analyzed ANOVA two-way and Tukey test (p<0,05). The mean values of the groups in MPa were: G2- 46.48(8.04), G3- 44.87(11.26), G5- 39.02 (13.45), G4-36.95(7.14), G1- 36.66(10.84) and G6- 32.71(13.83) which showed no statistically significant difference between groups (p =0.012). It can be concluded that the combined use the desensitizers and adhesive systems in human dentin etched there is no influence on bond strength.
112

Arquitectura de Cyber Situational Awareness (CySA) para la protección de infraestructuras críticas

Hingant Gómez, Javier Eric 15 April 2019 (has links)
[ES] La seguridad en el ciberespacio supone hoy en día un reto fundamental para cualquier organización ante el incesante aumento de ciberataques en todo el mundo. En una realidad tecnológica como la actual, en la que los dominios físico y lógico son cada vez más interdependientes, esta tarea es todavía más imprescindible pues las acciones en cualquiera de estos ámbitos pueden acarrear consecuencias devastadoras en ambos. Esto es si cabe más importante en el caso de infraestructuras críticas (IC), pues de su correcto funcionamiento depende el bienestar de toda una nación y sus ciudadanos. Se hacen por tanto necesarias nuevas soluciones que permitan afrontar de manera eficiente la defensa de toda clase de IC en este escenario híbrido, en el que las herramientas tradicionales de seguridad (firewall, IDS/IPS e incluso sistemas SIEM) resultan por sí solas insuficientes ante ataques a gran escala y donde alternativas más completas como los sistemas SCADA más recientes siguen orientadas a sectores muy específicos. La presente tesis doctoral plantea un enfoque innovador de Situational Awareness (SA) para la adecuada protección de IC en el contexto ciber-físico. En concreto, se propone una arquitectura genérica de SA híbrida que proporcione, mediante técnicas avanzadas de representación, la Common Operational Picture conjunta de las dimensiones física y ciber en un espacio único de visualización con el fin de facilitar la toma de decisiones al operador correspondiente. La arquitectura definida ha sido aplicada en dos soluciones distintas de Cyber Command & Control para la protección de IC: el sistema GESTPIC para la visualización avanzada de la SA ciber-física, y HYBINT como novedosa herramienta para la integración y el análisis de información de inteligencia. El modelo presentado en esta investigación ha sido validado en entornos de uso tanto simulados como reales, suscitando el interés de potenciales usuarios finales y confirmándose como propuesta pionera en su campo en los foros especializados en los que ha participado. / [CAT] La seguretat en el ciberespai suposa hui dia un repte fonamental per a qualsevol organització davant l'incessant augment de ciberatacs a tot el món. En una realitat tecnològica com l'actual, en la qual els dominis físic i lògic són cada vegada més interdependents, aquesta tasca és encara més imprescindible perquè les accions en qualsevol d'aquests àmbits poden implicar conseqüències devastadores en tots dos. Això és si cap més important en el cas d'infraestructures crítiques (IC), perquè del seu correcte funcionament depén el benestar de tota una nació i els seus ciutadans. Es fan per tant necessàries noves solucions que permeten afrontar de manera eficient la defensa de tota classe d'IC en aquest escenari híbrid, en el qual les eines tradicionals de seguretat (firewall, IDS/IPS i fins i tot sistemes SIEM) resulten per si soles insuficients davant atacs a gran escala i on alternatives més completes com els sistemes SCADA més recents segueixen orientades a sectors molt específics. La present tesi doctoral planteja un enfocament innovador de Situational Awareness (SA) per a l'adequada protecció d'IC en el context ciber-físic. En concret, es proposa una arquitectura genèrica de SA híbrida que proporcione, mitjançant tècniques avançades de representació, la Common Operational Picture conjunta de les dimensions física i ciber en un espai únic de visualització amb la finalitat de facilitar la presa de decisions a l'operador corresponent. L'arquitectura definida ha sigut aplicada en dues solucions diferents de Cyber Command & Control per a la protecció d'IC: el sistema GESTPIC per a la visualització avançada de la SA ciber-física, i HYBINT com a nova eina per a la integració i l'anàlisi d'informació d'intel·ligència. El model presentat en aquesta investigació ha sigut validat en entorns d'ús tant simulats com reals, suscitant l'interés de potencials usuaris finals i confirmant-se com a proposta pionera en el seu camp en els fòrums especialitzats en els quals ha participat. / [EN] Security in cyberspace is today a key challenge for any organization with the continuous growth of cyberattacks worldwide. In the current technological reality, in which physical and cyber domains are increasingly interdependent, this task is still most essential since actions in any of these scopes can lead to devastating consequences on both. This is even more important in case of critical infrastructures (CI), inasmuch as well-being of nations and their citizens depends on their proper functioning. New solutions are therefore needed in order to efficiently face the defence of all kind of CI in this hybrid scenario, in which traditional security tools (firewall, IDS/IPS and even SIEM systems) are by themselves insufficient against large-scale attacks and where more complete workarounds such as the most recent SCADA systems still remain focused on very specific sectors. This doctoral thesis introduces an innovative Situational Awareness (SA) approach for the suitable CI protection in the cyber-physical context. In particular, a hybrid SA architecture that provides, through advanced representation techniques, a Common Operational Picture of both physical and cyber dimensions in a unique visualization space is proposed to support operator's decision-making. The defined architecture has been applied in two different Cyber Command & Control solutions for CI protection: GESTPIC system for cyber-physical SA advanced visualization, and HYBINT as a novel tool for intelligence information integration and analysis. The model presented in this research has been validated in both simulated and real working environments, awakening the interest of potential end users and being confirmed as a ground-breaking proposal in its field in the specialized forums in which it has participated. / Hingant Gómez, JE. (2019). Arquitectura de Cyber Situational Awareness (CySA) para la protección de infraestructuras críticas [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/119448 / TESIS
113

Formulação híbrida-Trefftz com enriquecimento seletivo: aplicação a problemas bidimensionais da elasticidade / The hybrid-Trefftz formulation with selective enrichment: application to two-dimensional problems in elasticity

Souza, Charlton Okama de 14 August 2008 (has links)
Este trabalho insere-se no âmbito das formulações não convencionais em elementos finitos. Particularmente, introduzem-se alguns aspectos do método dos elementos finitos generalizados (MEFG) e do clássico refino-p na consagrada formulação híbrida-Trefftz de tensão para a elasticidade bidimensional. A formulação apresentada aproxima diretamente dois campos independentes: o de tensões no domínio dos elementos e o de deslocamentos nas fronteiras dos elementos. Baseado na estrutura de enriquecimento centrada em nuvens, proposta pelo MEFG, podem ser selecionadas oportunamente regiões, formadas por um conjunto de elementos e fronteiras de elementos, onde o espaço da aproximação é adequadamente enriquecido mediante o refino-p. Neste contexto campos auto-equilibrados de tensões, derivados da solução da equação de Navier, são utilizados para compor a aproximação no domínio dos elementos, enquanto nas fronteiras dos elementos o campo de deslocamentos é construído a partir de bases específicas de aproximação; seja a base inicial, formada por funções de forma lineares, ou bases enriquecidas com polinômios hierárquicos, não hierárquicos e funções trigonométricas. Aborda-se também, ainda que preliminarmente, um estudo de painéis com múltiplas fissuras pelo método da partição em formulação híbrida-Trefftz com enriquecimento seletivo. As análises numéricas realizadas revelaram, em geral, uma formulação de ótimo desempenho, caracterizada por uma notável capacidade de aproximação dos campos de tensões e deslocamentos, elevada robustez numérica e reduzido dispêndio computacional. / This work is inserted in the context of unconventional formulations in the finite elements method. Particularly, some aspects of the generalized finite elements method (GFEM) and the classic p-refinement are introduced in the well known hybrid-Trefftz stress formulation for the two dimensional elasticity. The presented formulation approximates two independent fields: the one of stresses in the elements domain and the one of displacements in the boundaries of the elements. Based on the enrichment structure centered in clouds, proposed by the GFEM, some regions, formed by a group of elements and boundaries of elements where the approximation space is adequately enriched by the p-refinement, can be opportunely selected. In this context, self-equilibrated stress fields, derived from the solution of the Navier equation, are used to compose the approximation in the elements domain, whereas the displacements field in the borders of the elements is built from specific approximation bases, that is, the initial base formed by linear shape functions, or, bases enriched with hierarchical polynomials, nonhierarchical ones and trigonometric functions. Also, although preliminarily, a study of the multiple-cracked panels is done using the Splitting Method with a hybrid-Trefftz formulation and a selective enrichment. The numeric analyses done revealed, in general, a high performance formulation characterized by a great capacity of approximation the stress fields and displacements, high numeric robustness and reduced computer expenditure.
114

Previsão de cargas não residenciais mistas por redes neurais ARTMAP Fuzzy /

Alves, Marleide Ferreira. January 2019 (has links)
Orientador: Anna Diva Plasencia Lotufo / Resumo: Os sistemas de energia elétrica estão passando por transformações. Aos poucos, técnicas de sistemas de informação estão sendo incorporadas aos sistemas atuais de energia. Basicamente este é o conceito de smart grid. Esta incorporação visa aumentar a eficiência dos sistemas de energia elétrica, pois os diversos agentes envolvidos em todo o sistema terão à disposição informações mais completas, precisas e de forma praticamente instantânea. Como consequência, haverá um aumento significativo de dados disponíveis para serem empregados de variadas formas. Um exemplo do uso de dados é a previsão de demanda de energia elétrica. De uma forma geral, previsões servem como suporte para suprir demandas, estimar custos ou justificar investimentos futuros. No campo de previsão de demanda de cargas elétricas existem diversos modelos na literatura, a grande maioria se concentra em níveis mais agregados, que atendem a grandes consumidores em que o fornecimento de energia é feito, por exemplo, por uma subestação. Uma smart grid também coloca à disposição as informações de consumo de energia em níveis cada vez menos agregados, como uma residência ou um prédio comercial. Realizar previsões neste nível é um desafio, pois essas demandas são muito influenciadas pelo comportamento humano. Diferentemente dos níveis mais agregados, modelos de previsão para níveis menos agregados, ou desagregados, ainda são poucos. O objetivo deste trabalho é fazer a previsão de cargas elétricas não residenciais mistas ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Electrical power systems are in transformation nowadays. Gradually, information system technology are being introduced to the energy systems. Basically, this is the concept of smart grid. This new concept aims to improve the efficiency of the energy systems, once the evolved agents will provide complete and precise information instantaneously. This way, a significant increase in data will be available to be employed in several forms. One example in using these data is electric energy demand forecasting. In general, predictions are support to provide electric load demand, estimate costs or justify future investments. Concerning electric load demand, there are several models in the literature, and the majority is concentrated in aggregated levels, attending large consumers, where, for example, the energy supply is provided by a substation. Considering the smart grid, there are consumption information in less aggregated levels as for example residences or commercial buildings. Therefore, realizing predictions in these levels (less aggregated) is a challenge, once the demand is influenced by the human behavior. The models for predicting loads in aggregated levels are common, in the contrary of less aggregated that are few. This work aims to predict short term mixed nonresidential electric loads using data from a Brazilian University. Firstly, Fuzzy ARTMAP Neural Network is chosen to execute the predictions, and afterwards a hybrid methodology containing Fuzzy ARTMAP and Square Mi... (Complete abstract click electronic access below) / Doutor
115

Valor da captura híbrida para o papilomavírus humano (HPV) no seguimento de pacientes submetidos à conização do colo uterino devido a lesão intraepitelial de alto grau por cirurgia de alta frequência (CAF) / The value of the HPV DNA test on the follow-up of the patients treated for high grade cervical intraepithelial lesions by conization with large loop excision of the transformation zone (LLETZ)

Roncaglia, Maria Teresa 22 May 2012 (has links)
INTRODUÇÃO: A lesão intraepitelial cervical de alto grau causada pelo HPV, precursora do câncer cervical, é facilmente diagnosticada e seu tratamento pode ser realizado de maneira ambulatorial, sem muitas complicações. Mesmo assim, o seguimento das pacientes tratadas deve ser feito de maneira criteriosa e sistemática para que a recorrência ou persistência da doença não passe despercebida. Conseguir identificar o grupo de pacientes com maior probabilidade de recorrência ou persistência da doença facilitaria sobremaneira esse seguimento, diminuindo o ônus econômico e psicológico que o seguimento generalizado produz. O objetivo deste trabalho é identificar marcadores que possam indicar o grupo de pacientes com maior possibilidade de recorrência da lesão intraepitelial cervical de alto grau. MÉTODOS: Neste estudo 114 mulheres com diagnóstico de lesão intraepitelial cervical de alto grau foram submetidas à conização cervical por cirurgia de alta frequência (CAF) no Setor de Patologia do Trato Genital Inferior (PTGI) da Divisão da Clínica Ginecológica do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HC-FMUSP) no período entre março de 2006 e maio de 2009. O seguimento foi realizado a cada seis meses durante o período de 24 meses. No seguimento foi coletada a citologia cervical, captura híbrida para HPV e realizada a colposcopia. Foram avaliados os testes de captura híbrida para HPV coletadas durante o seguimento, imuno-histoquímicos para oncoproteína viral E6 e proteína p16 na peça cirúrgica como possíveis marcadores de recorrência. RESULTADOS: A avaliação anatomopatológica da peça cirúrgica diagnosticou 85 (74,6%) casos de lesão intraepitelial cervical de alto grau e 29 (25,4%) casos de lesão intraepitelial de baixo grau. Nessas peças, 45 (39,5%) apresentaram expressão positiva para oncoproteína E6 e 69 (60,5%) apresentaram expressão negativa para E6; 74 (64,9%) apresentaram expressão positiva para p16 e 40 (35,1%) apresentaram expressão negativa para p16. A oncoproteína E6 não se associou com a apresentação mais grave da doença. Já a proteína p16 esteve positiva em 68 (80%) casos diagnosticados como lesão intraepitelial de alto grau e negativa em 23 (79,3%) casos com diagnóstico anatomopatológico de lesão intraepitelial de baixo grau ou cervicite crônica. A CH coletada no primeiro retorno apresentou sensibilidade de 83,3%, especificidade de 87,8%, VPP de 50% e VPN de 97,3%. Comparando a CH coletada no primeiro retorno com a citologia coletada após os 24 meses de seguimento, a CH apresentou sensibilidade de 75%, especificidade de 83,1%, VPP de 20% e VPN de 98,3%. CONCLUSÕES: A expressão das oncoproteína E6 e proteína p16 na peça cirúrgica não demonstraram ter valor para predizer recorrência no seguimento de pacientes tratadas por lesão intraepitelial cervical de alto grau, mesmo a p16 estando associada à presença de lesões mais graves. A CH pode ser usada como um teste preditivo de recorrência durante o seguimento de pacientes tratadas por lesão intraepitelial de alto grau. O VPN do teste é bastante alto e seu resultado negativo, seis meses após o tratamento indica uma taxa baixíssima de recorrência da doença / INTRODUCTION: The high grade cervical intraepithelial lesion caused by HPV, a pre-malignant condition, is easily diagnosed and its treatment can be done in outpatients without many complications. Nevertheless the patients follow-up must be done in a very systematic way to avoid any recurrence or persistence of the disease. To be able to identify the group of patients with higher rate of recurrence or persistence of the disease would make this follow-up much easier and decrease the economic and psychological burden of stressed outcome. The goal of our study is to identify markers that could indicate the group of patients more likely to recur. METHODS: In this study, 114 women diagnosed with high grade cervical intraepithelial lesion were treated with LLETZ at the Discipline of Gynecology, Faculty of Medicine, São Paulo University from March 2006 and May 2009. The follow-up visits after the treatment included Pap smear, HPV DNA test and colposcopy and occurred every 6 months for 24 months. The markers evaluated were the HPV DNA test collected during the follow-up and immunohistochemical tests performed on the surgical specimen: E6 oncoprotein and protein p16. RESULTS: We found 85 cases (74,6%) of HSIL and 29 cases (25,4%) of LSIL in the surgical specimen obtained with the LLETZ. The E6 oncoprotein was expressed in 45 (39,5%) and not expressed in 69 (60,5%) of the specimen; 74 (64,9%) expressed p16 and 40 (35,1%) didnt express p16. The E6 oncoprotein was not associated with severe presentation of the disease. The protein p16 was positive in 68 (80%) cases of diagnosed HSIL and negative in 23 (79,3%) cases with diagnosed LSIL or chronic cervicitis. The HPV DNA test collected at the first follow-up consult at 6 months presented a sensitivity of 83,3% specificity of 87,8%, positive predictive value (PPV) of 50% and negative predictive value (NPV) of 97,3%. Comparing the HPV DNA test collected at the first follow-up visit and the cervical cytology collected at the fourth and last follow-up visit at 24 months, the HPV DNA test presented a sensitivity of 75%, specificity of 83,1%, PPV of 20% and NPV of 98,3%. CONCLUSIONS: The E6 oncoprotein and protein p16 expression on the surgical specimen were not able to predict recurrence of the disease during the follow-up of the patients. The HPV DNA test can be used as a marker of the recurrence on the follow-up of patients treated for HSIL with LLETZ. The HPV DNA test negative result at the 6 month follow-up visit represents an extremely low recurrence rate
116

Proposta de uma estrutura híbrida de controle para sistemas de excitação de geradores síncronos distribuídos / Proposal of a hybrid control scheme for excitation systems of distributed synchronous generators

Piardi, Artur Bohnen 21 November 2017 (has links)
Com o advento da geração distribuída foi permitido aos sistemas de distribuição a possibilidade de operação de forma ilhada dos sistemas interligados de grande porte. Apesar de suas vantagens, do ponto de vista técnico, ainda existe uma série de desafios que necessitam ser superados para a plena aplicação desse conceito. Um desses desafios é definido pela transição dos modos operativos dos geradores distribuídos durante o processo de ilhamento. Da forma em que é reportada na literatura, infere-se que tal transição é realizada de um modo inadequado, amplificando os transitórios observados nas grandezas do gerador distribuído - e por consequência, da rede em que o mesmo se conecta - durante o processo de ilhamento, o que não é desejável. No contexto apresentado, a principal contribuição desta pesquisa está em propor uma estrutura híbrida de controle a ser aplicada aos sistemas de excitação de geradores síncronos que operam em sistemas de distribuição que permitem a operação ilhada de determinadas porções de suas redes. A principal característica da estrutura proposta está em atenuar os transitórios das variáveis do gerador controlado durante o processo de ilhamento. Além disso, o arranjo da estrutura proposta estabelece um compromisso entre a potência reativa e a tensão terminal do gerador controlado, quando o mesmo opera em paralelo com os sistemas interligados de grande porte. Nessa condição, o sistema de controle mantém a potência reativa próxima da referência ajustada atendendo a uma faixa adequada de valores de tensão terminal. / With the advent of distributed generation, the possibility of autonomous operation regarding the bulk power systems was allowed to the distribution systems. Despite its advantages, from the technical point of view, there are lots of challenges that need to be overcome for the full application of this concept. One of these challenges is the transition of distributed generators operating modes during the islanding process. Based in the literature survey, it is inferred that transition is performed in a wrong way, which amplifies the transients in controlled generator quantities and consequently, of the network connected to it during the islanding process, which is undesirable. In this context, the main contribution of this research is the proposal of a hybrid control structure to be applied to the excitation systems of synchronous generators that operate in distribution systems whose islanded operation of determined portions of its grids is permitted. The main characteristic of the proposed structure is the attenuation of transients of the controlled generator quantities during the islanding process. Furthermore, the design of this structure provides a compromise between the generator reactive power and terminal voltage when it operates in parallel with the bulk power systems. That way, the control system maintains the reactive power close to the adjusted reference attending an appropriate range of terminal voltage values.
117

Integração da ventilação híbrida e da iluminação natural em saletas comerciais na cidade de São Paulo: influência de parâmetros de projeto / Daylighting and hybrid ventilation integration in cellular offices in the city of São Paulo: design parameters influence.

Santesso, Caroline Antonelli 11 November 2016 (has links)
Atualmente, os edifícios selados hermeticamente e com as chamadas \"peles de vidro\" estão presentes em diversos países, e possuem, como consequência, um elevado consumo de energia elétrica para conseguir manter o conforto ambiental dos usuários. Contudo, é possível se beneficiar de uma maior eficiência energética nesses espaços através da combinação de soluções ativas e passivas. Esse estudo tem como objetivo principal avaliar a influência de parâmetros de projetos, tais como o formato da sala, tamanho e orientação das aberturas na fachada, no consumo de energia e no conforto visual em saletas comerciais com ventilação híbrida e integração da iluminação natural com a artificial na cidade de São Paulo. As saletas comerciais analisadas possuem uma área média, diferentes formatos e diferentes aberturas em uma só fachada, representando a solução arquitetônica mais comum encontrada nesse tipo de edifício. Através de análise energética realizada por meio do programa EnergyPlus e da análise lumínica com o programa DIVA-for-Rhino, verificou-se que o formato da sala é essencial para a decisão de um percentual de área de abertura na fachada (PAF) que consuma menos energia. Os resultados mostraram que o uso da ventilação híbrida sempre representou uma economia, atingindo uma redução de até 51% do consumo do ar condicionado para resfriamento e até 26% do consumo de energia total, com os PAF´s de 40, 70 e 100%. Seria interessante considerar elementos de proteção solar que não diminuam a eficácia da ventilação e iluminação naturais nesses ambientes, para se aliar o baixo consumo de energia com menores riscos de ofuscamento. Desta forma, o trabalho auxilia a incorporação destas estrategias para uma maior economia de energia no desenvolvimento do projeto arquitetônico desta tipologia de edifício comercial. / Nowadays, sealed airtight office buildings and so-called \"glass curtain wall\" are present in many countries, and have as a result a high consumption of electric energy to be able to maintain the environmental comfort of the users. However, the combination of passive and active strategies could improve the energy efficiency in these spaces. This study aims to evaluate the design parameters influence, such as rooms shape, the openings size and orientation, in the energy consumption and in the visual comfort in cellular offices with hybrid ventilation system and the integration of daylight and artificial lighting in São Paulo. The analyzed cellular offices have an average area, different shapes and different openings in one facade, representing the more common architectural characteristics found in this type of building in that context. Energy analyses in EnergyPlus and daylight studies using DIVA-for-Rhino were conducted. It was found that the rooms shape is essential for the determination of the window-to-wall-ratio (WWR) for reducing energy consumption. The results showed that the hybrid ventilation use always represented an economy, reaching reduction values up to 51% in the consumption of air conditioning for cooling and up to 26% in cellular offices total consumption, with a WWR of 40, 70 and 100%. It would be interesting to consider sun shading elements that do not reduce the effectiveness of natural ventilation and daylighting in these environments to combine low power consumption with a lower risk of glare. In this way, the work helps the incorporation of these strategies for save energy in the development of the architectural design of this type of commercial building.
118

Movimentos sociais, território e resistência: a luta dos trabalhadores e do movimento de luta por moradia pela vila Operária em Guarulhos, SP / Social movements, territory and resistance: the struggle of the workers and the movement for housing in Vila Operária in Guarulhos

Maíra Carvalho de Moraes 05 October 2018 (has links)
O presente trabalho tem como objetivo apresentar a história da resistência e da luta dos moradores e do Movimento de Luta por Moradia (MLM) pelo bairro de Vila Operária em Guarulhos, SP. A partir da sistematização das experiências dos moradores, buscou-se construir uma história da luta do bairro através das ações de resistência às reintegrações de posse em um espaço com problemas de regulamentação fundiária disputado pela iniciativa privada, por posseiros e pelo Estado. A partir da análise das estruturas econômicas e a superestrutura Estado e suas instituições ao longo da história do Brasil, verificou-se a continuidade da exclusão social e da concentração de renda e fundiária, que contribui com o crescimento das periferias na Região Metropolitana de São Paulo. Os movimentos sociais de moradia pela Reforma Urbana buscam a regularização fundiária de bairros estabelecidos, caso da Vila Operária, e têm se dedicado em defender os direitos constitucionais e o respeito às leis municipais e ao Plano Diretor. A análise da experiência dos moradores e da Vila Operária permitirá avaliar as ações de movimentos sociais de moradia pela Reforma Urbana em um contexto de regulação híbrida do Direito em que Estado e empresas atuam em conjunto na repressão às ações coletivas e à democracia / This reserch aims to present the history of resistance and struggle of the residents and of the Movement for Struggle for Housing (MLM) in the neighborhood of Vila Operária in Guarulhos, SP. From the systematization of the residents\' experiences, the aim was to construct a history of the neighborhood struggle through the actions of resistance to the reintegration of tenure in a space with land regulation problems disputed by the private initiative, squatters and the State. From the analysis of economic structures and the superstructure - State and its institutions - throughout the history of Brazil, the continuity of social exclusion and concentration of income and land ownership has been verified, which contributes to the growth of the peripheries in the Metropolitan Region of Sao Paulo. The social movements of housing by the Urban Reform seek the land regularization of established neighborhoods, in the case of Vila Operária, and has been dedicated in defending the constitutional rights and the respect to the municipal laws and the Master Plan. The analysis of the experience of the residents and Vila Operária will allow to evaluate the actions of social movements of housing by the Urban Reform in a context of Hybrid Law regulation in which State and companies act together in the repression of collective actions and democracy
119

Avaliação de um sistema descentralizado de tratamento de esgotos domésticos em escala real composto por tanque séptico e wetland construída híbrida / Evaluation of a decentralized system of domestic sewage treatment in real scale composed of septic tank and hybrid constructed wetland

Alexandre Antonio Jacob de Mendonça 06 April 2016 (has links)
A concentração demográfica e de sistemas coletivos de esgotamento sanitário dentro do perímetro urbano da maioria dos municípios brasileiros, dificulta a viabilização do fornecimento de serviços de tratamento de esgotos domésticos à habitações e núcleos habitacionais isolados situados em áreas periurbanas e rurais, intensificando os danos provocados pela poluição de origem antrópica ao meio ambiente e à preservação da saúde pública. Para contribuir no equacionamento deste problema, o presente estudo teve por finalidade avaliar uma wetland construída híbrida em escala real, composta por uma unidade com fluxo contínuo subsuperficial vertical seguida por uma unidade de fluxo contínuo subsuperficial horizontal, cultivadas com capim Vetiver, para o tratamento de efluente proveniente de tanque séptico. A presente configuração experimental busca uma solução de baixo custo e simplificada para o tratamento descentralizado de esgotos domésticos. A estação experimental de tratamento de esgotos, parte integrante e um dos produtos da Rede Nacional de Tratamento de Esgotos Descentralizados RENTED, foi construída no Centro Tecnológico de Hidráulica CTH / Escola Politécnica EPUSP, campus Butantã da USP, em São Paulo. O esgoto bruto foi proveniente do Conjunto Residencial da USP e do restaurante central da Cidade Universitária. As vazões média e máxima de esgoto bruto, respectivamente, de 640L.d-1 e 1600L.d-1, foram aplicadas à entrada do TS de 5.000L e deste escoaram por gravidade à entrada da wetland construída híbrida, com TDH total de 2,8d e 1,1d, respectivamente, sob aplicação das vazões média e máxima de projeto. O monitoramento do experimento em campo, incluindo o período inicial de partida, durou 6 meses consecutivos. Foram avaliados os parâmetros físico-químicos e microbiológicos do esgoto bruto e do efluente do tanque séptico e das câmaras da wetland construída híbrida durante 97 dias consecutivos. Os resultados indicaram que tanto as mudas jovens quanto as adultas de capim Vetiver adaptaram-se bem às condições ambientais. As eficiências médias de remoção no efluente tratado final quanto à matéria orgânica carbonácea foram de 96 por cento para DBO5,20 e 90 por cento para DQO, 40 por cento para N-total, 23 por cento para N-amoniacal total, 60 por cento para P-total, 52 por cento para P-PO4, 74 por cento para SST, 96 por cento para SSV, 75 por cento para sólidos sedimentáveis, 44 por cento para SDV, 88 por cento para sulfeto total, e 97 por cento para óleos e graxas totais, variando entre 73 por cento a 100 por cento . Cerca de 80 por cento da fração orgânica da matéria nitrogenada presente no esgoto bruto foi removida. A remoção de coliformes termotolerantes foi, em média, de 2 e 3 unidades log, e de Escherichia Coli, média de 1 e 3 unidades log, respectivamente, sob aplicação das vazões máxima e média, Giardia sp, média de 99,995 por cento , Cryptosporidium sp, média de 98,7 por cento , Enterovírus, média de 99,6 por cento , e Ascaris sp, média de 0,10 ovo/L. A remoção de sulfetos propiciou a geração de efluente tratado sem odores desagradáveis. A diminuição da vazão aplicada e a elevação do TDH influenciaram positivamente no desempenho do sistema com relação às remoções dos parâmetros físico-químicos e microbiológicos. Com base no presente estudo, ficou evidente o benefício da associação de wetlands construídas com fluxo vertical e horizontal no tratamento de efluente de tanque séptico. O capim Vetiver apresentou bom potencial de utilização em wetlands 8 construídas para tratamento de esgotos domésticos. O sistema experimental de tratamento apresentou flexibilidade operacional, mantendo bom desempenho inclusive nos períodos de sobrecarga. A qualidade do efluente tratado final obtido no presente estudo atende às exigências de lançamento e aos padrões de emissão de efluentes líquidos em corpos dágua e em sistemas públicos de esgotamento sanitário definidos na legislação ambiental federal e do Estado de São Paulo. A tecnologia de wetlands construídas híbridas associada ao tratamento de efluentes de tanque séptico apresentou bom potencial para o tratamento descentralizado de esgotos domésticos, inclusive em regiões com pouca disponibilidade de área livre. / The demographic concentration and collective systems of sanitation inside the urban perimeter of most Brazilian municipalities, hampers the feasibility of providing sewage treatment services to domestic dwellings and housing isolated nuclei located in peri-urban and rural areas, intensifying the damage caused by pollution of human origin to the environment and to the preservation of public health. For help in solving this problem, the present study had the purpose to evaluate a hybrid constructed wetland full-scale, composed of a unit with continuous vertical subsurface flow followed by a continuous horizontal subsurface flow unit, grown with Vetiver grass, for the treatment of effluent from septic tank. This experimental search setting a low-cost and simplified solution for decentralized treatment of household sewage. The experimental sewage treatment station, integral and one of the products of the Rede Nacional de Tratamento de Esgotos Descentralizados RENTED, was built on the Centro Tecnológico de Hidráulica CTH / Escola Politécnica EPUSP, campus Butantã of USP, in São Paulo. The raw sewage was coming from the residential condominium of the USP and the central restaurant of the University City. The average and maximum flows of raw sewage, respectively, of 640L.d-1 and 1600L.d-1, have been applied to the septic tank input to 5,000L and drained by gravity from the edge of the hybrid constructed wetland with TDH total of 2.8d and 1.1d, respectively, under application of the average and maximum flow rates. Monitoring the experiment in the field, including the early period, lasted 6 months. They were evaluated the physico-chemical and microbiological parameters of raw sewage and effluent from septic tank and the chambers of hybrid constructed wetland during 97 consecutive days. The results indicated that both the young seedlings as the adults of Vetiver grass have adapted well to environmental conditions. The average removal efficiencies in the final treated effluent as to carbonaceous organic matter were 96 per cent for BOD5,20 and 90 per cent for COD, 40 per cent for Ntotal, 23 per cent for N-ammoniacal, 60 per cent for P-total, 52 per cent for P-PO4, 74 per cent for SST, 96 per cent for SSV, 75 per cent for settleable solids, 44 per cent for SDV, 88 per cent for total sulfide, and 97 per cent for oils and greases totals, ranging from 73 per cent to 100 per cent . About 80 per cent of the organic fraction of nitrogen matter present in the raw sewage has been removed. The thermotolerants coliforms removal was, in average, of 2 and 3 log units, and Escherichia Coli, average of 1 and 3 log units, respectively, under application of the maximum and average flow rates, Giardia sp, average of 99.995 per cent , Cryptosporidium sp, average of 98.7 per cent , Enterovirus, average of 99.6 per cent , and Ascaris sp, average of 0.10 eggs/L. Removal of sulfides allowed the generation of treated effluent without unpleasant odors. The decrease in flow rate applied and the elevation of TDH influenced positively on system performance with respect to removals of chemical-physical and microbiological parameters. Based on this study, it became apparent the association benefit constructed wetlands with vertical and horizontal flow in the treatment of wastewater of septic tank. The Vetiver grass has good potential for use in constructed wetlands for wastewater treatment. The experimental system of treatment presented operational flexibility while maintaining good performance even in periods of overload. The quality of the final treated effluent obtained in this study 10 meets the requirements and emission standards of liquid effluents in water bodies and in public sanitation systems defined in federal environmental legislation and the State of São Paulo in Brazil. Hybrid constructed wetlands technology associated with the septic tank effluent treatment showed good potential for decentralized domestic wastewater treatment, including in regions with low availability of free area.
120

Análise computacional de um motor turbo-foguete aspirado como motor auxiliar para veículos lançadores de satélites

Débora Cristina Coutinho Vilas Boas 14 December 2007 (has links)
Os motores de foguetes baseados em ciclos combinados têm sido largamente discutidos e aplicados nos sistemas de propulsão de veículos lançadores reutilizáveis devido ao fato de apresentarem baixa relação empuxo x peso e elevado impulso específico, podendo assim ampliarem a carga útil transportada. Este trabalho tem por finalidade explanar a variedade de motores de foguetes baseados em ciclos combinados. E dentro desta perspectiva apresentar um estudo de um motor de ciclo combinado que é híbrido entre motor turbo-foguete e propulsão aspirada, denominado motor turbo-foguete aspirado - ATR como uma proposta de motor auxiliar reutilizável para veículos lançadores de satélites. A análise do motor turbo-foguete aspirado proposto será feita através do desenvolvimento de uma metodologia computacional baseada em linguagem de programação orientada a objeto (C++) e o código aberto Cantera (GOODWIN, 2002). Esta análise consiste na obtenção de dados termodinâmicos e parâmetros de seus componentes para a configuração do motor ATR proposto, de modo que venha facilitar o desenvolvimento do projeto do motor do tipo ATR. Ao término deste trabalho ter-se-á uma ferramenta de análise do motor ATR bem como demais motores que apresentem a propulsão aspirada em seu sistema de propulsão.

Page generated in 0.0274 seconds