• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 249
  • 4
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 257
  • 125
  • 59
  • 32
  • 32
  • 31
  • 31
  • 31
  • 30
  • 26
  • 25
  • 25
  • 24
  • 22
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Achados clínicos, hemodinâmicos e hemogasométricos da infusão contínua de propofol associado ou não ao tramadol em ovelhas submetidas à videolaparoscopia /

Lopes, Maristela de Cassia Seúdo. January 2014 (has links)
Orientador: Carlos Augusto Araújo Valadão / Banca: André Escobar / Banca: Renata Gebara Sampaio Dória / Banca: Francisco José Teixeira Neto / Banca: Rafael Resende Faeiros / Resumo: Foram utilizadas 24 ovinos, fêmeas, Santa Inês, com idade entre três a seis anos, com peso médio de 41±4 Kg, submetidas à videolaparoscopia. Os animais foram distribuídos de forma aleatória em quatro grupos, designados como GP (propofol), GT1,3 (tramadol 1,3), GT2,6 (tramadol 2,6) e GTepi (tramadol epidural). Todos os animais foram induzidos e mantidos à anestesia com propofol (6,0 mg/kg/IV) seguido taxa de infusão 0,5 mg/kg/min. A analgesia foi realizada com uso do tramadol administrado na forma de bolus (1,5 mg/kg) seguido pela infusão intravenosa de 1,3 mg/kg/h (GT1,3; n=6); bolus (3,0 mg/kg) seguido pela infusão intravenosa de 2,6 mg/kg/h (GT2,6; n=6) e administrado pela via epidural, na dose de 2,0 mg/kg (GTepi, n=6). Um grupo controle recebeu infusão de solução salina (GP, n=6). Todos os animais foram mantidos em ventilação controlada. Foram avaliados os parâmetros hemodinâmicos, respiratórios e hemogasométricos antes da indução (M0), 15 (M15) e 30 (M30) após o ínicio da infusão de propofol e tramadol ou NaCl0,9%, a cada 10 minutos ( M40, M50 e M60) com o animal em posição de cefalodeclive e com pneumoperitônio e por um período adicional de 30 minutos (M70, M80 e M90) com o animal em decúbito dorsal e sem a presença do pneumoperitônio. Concomitantemente, avaliou-se a qualidade da indução e recuperação anestésica, cortisol plasmático, grau e duração da analgesia (seis horas do pós-cirúrgico) e o uso de analgesia resgate nos períodos intra e pós-operatório. Não houve variações significativas na frequência cardíaca, pressão arterial, pressão de oclusão da artéria pulmonar, índice da resistência vascular sistêmica e índice do trabalho do ventrículo esquerdo. Nos primeiros 15 minutos constatou-se uma diminuição significativa do volume sistólico em todos os grupos, o qual refletiu na redução significativa do índice cardíaco. Durante o pneumoperitônio essa redução se ... / Abstract: Twenty four sheep, all female, Santa Ines, age ranged from three to six years and mean weight of 41 ± 4 kg, underwent laparoscopy procedures. The ewe were randomly divided in four groups, designated as GP (propofol), GT1,3 (tramadol 1.3), GT2.6 (tramadol 2,6) and GTepi (epidural tramadol). All ewe were induced with propofol (6.0 mg.kg-1 IV) and anesthesia was maintained with a CRI of propofol (0.5 mg.kg.min-1). Analgesia was obtained with tramadol bolus (1.5 mg kg-1) followed by 1.3 mg kg min-1 CRI (GT1.3, n=6); bolus (3.0 mg kg-1) followed by 2.6 mg kg min-1 CRI (GT2.6, n=6) and by infusion of tramadol epidurally (2.0 mg.kg-1). In a control group recieved saline CRI (GP, n=6). The animals underwent mechanical ventilation Hemodynamic, respiratory and metabolic parameters were evaluated during the preoperative (M0) periods, intraoperative (M15 -M30: dorsal recumbence, M30 to M60: with abdomen insufflation and Trendelemburg positioning and M60 - M90: dorsal recumbence without abdomen insufflation). In the same time, we assessed the quality of induction and recovery from anesthesia, plasma cortisol, degree and duration of analgesia (six hours of post surgical) and use of rescue analgesia in the intra and postoperatively. There were no significant changes in heart rate (HR). The body temperature decreased from M30 until the end of anesthesia (M90) in all groups. The partial pressure of oxygen in arterial blood (PaO2) increased in all groups from M15 as well as the partial pressure of carbon dioxide (PaCO2) from the M30 to M60 in GP and GT1.3, from the M50 to M60 in GT2.6 and in M60 in GTepi. There was a decrease in pH from M30 to M70 in GT1.3, from M40 and M90 in GP and GT2.6 and from M40 to M80 in GTepi. In hemodynamic evaluation, cardiac index (CI) decreased from M30 to M60 in animals GP and GTepi and M15 in GT1.3. In stroke volume (SV) was a reduction from M15 to M60 in GP, GT1.3, GT2.6 and from M30 to M70 in GTepi. The rescue analgesia ... / Doutor
52

Efeitos de diferentes concentrações de isofluorano sobre a perfusão tecidual em cães

Floriano, Beatriz Perez [UNESP] 24 December 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:17Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-12-24Bitstream added on 2014-06-13T19:25:38Z : No. of bitstreams: 1 floriano_bp_me_araca.pdf: 900216 bytes, checksum: 5e9055fdcd50dd5a0e5c2ee686686c68 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Objetivou-se com este estudo avaliar os efeitos do isofluorano e tempo de anestesia com o mesmo sobre a perfusão tecidual de cães sob duas diferentes concentrações. Oito cães da raça Beagle foram anestesiados em múltiplos de CAM correspondentes a 1,5 (G1,5) e 2,0 (G2,0) CAM por duas horas, sendo mensuradas a cada 20 minutos as variáveis frequência cardíaca (FC), pressão sistólica (PAS), média (PAM) e diastólica (PAD), pressão da artéria pulmonar média (PAPm), pressão capilar pulmonar média (PCPm), pressão venosa central (PVC), índice cardíaco (IC), índice sistólico (IS), índice de trabalho ventricular esquerdo (ITVE), índice de resistência periférica total (IRPT), índice de resistência vascular pulmonar (IRVP), índice de oferta de oxigênio (IDO2), índice de consumo de oxigênio (IVO2), taxa de extração de oxigênio (TeO2), saturação venosa mista de oxigênio (SvO2) e lactato sanguíneo arterial. As médias de PAM, IC, IS e ITVE, diferiram significativamente entre os grupos, o que não foi observado nas variáveis IRPT e IRVP, as quais apresentaram diferença somente entre momentos de um mesmo grupo. Da mesma forma, houve diminuição progressiva da IRPT em G1,5, mas não em G2,0. Houve redução de IDO2 em G2,0 quando comparada a G1,5, mas não de IVO2. O lactato apresentou valores acima dos limites de referência, não diferindo entre grupos e reduzindo-se ao longo do tempo, enquanto que SvO2 foi menor em G2,0, acompanhada de maior TeO2 neste grupo. Concluiu-se que a perfusão global é prejudicada por concentrações maiores de isofluorano, ao passo que a perfusão periférica é mantida. Existe um limite para o grau de vasodilatação periférica causada pelo isofluorano em cães e o tempo de exposição ao anestésico interfere com a dinâmica cardiovascular tanto quanto sua concentração / The aim of this study was to evaluate the effects of isoflurane and anesthetic time period on tissue perfusion of dogs under two different concentrations. Eight beagle dogs were anesthetized in MAC multiples correspondent to 1.5 (G1.5) e 2.0 (G2.0) MAC for two hours, being the following variables collected every 20 minutes: heart rate (HR), arterial systolic (SAP), mean (MAP) and diastolic (DAP) pressures, pulmonary artery mean pressure (PAPm), pulmonary artery wedge pressure (PAWP), central venous pressure (CVP), cardiac index (CI), systolic index (SI), left ventricle work index (LVWI), total peripheral resistance index (TPRI), pulmonary vascular resistance index (PVRI), oxygen delivery index (IDO2), oxygen consumption index (IVO2), oxygen extraction (TeO2), mixed venous oxygen saturation (SvO2) and arterial blood lactate. Mean values of MAP, CI, SI and LVWI were different between groups, and such differences were not observed in TPRI and PVRI, which differences were only significant between time points in each group. In addition, there was progressive reduction of TPRI in G1.5, but not G2.0. There was a reduction of IDO2 in G2.0 when compared to G1.5, but not IVO2. Lactate levels were above reference limits, with no difference between groups and decreasing over time, whereas SvO2 was lower in G2.0, accompanied by higher TeO2 in that group. We conclude that global perfusion is impaired by higher concentrations of isoflurane, while peripheral perfusion is maintained. There is a limit to the degree of vasodilation caused by isoflurane in dogs and the time of exposure to the anesthetic interferes with cardiovascular dynamics as much as its concentrations
53

Peptídeo natriurético tipo B e avaliação clínica no diagnóstico do perfil hemodinâmico na síndrome de insuficiência cardíaca aguda descompensada : comparação com o ecocardiograma com Doppler tissular

Almeida Júnior, Gustavo Luiz Gouvêa de January 2011 (has links)
Resumo não disponível
54

Comparação entre sinais e sintomas clínicos e variáveis hemodinâmicas obtidas por ecocardiografia em pacientes com insuficiência cardiáca crônica

Silva Neto, Luís Beck da January 2000 (has links)
Resumo não disponível.
55

Análise do reprocessamento de catéteres de hemodinâmica nos hospitais da cidade do Recife PE

Myrna Tenório de Sousa Bomfim, Flávia 31 January 2009 (has links)
Made available in DSpace on 2014-06-12T15:52:14Z (GMT). No. of bitstreams: 2 arquivo2951_1.pdf: 1447636 bytes, checksum: a32b6b9495f051a2417783309334f24c (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2009 / INTRODUÇÃO: o reprocessamento de dispositivos de uso único (DUUs) é uma prática utilizada mesmo em países desenvolvidos e na grande maioria daqueles em desenvolvimento, face ao elevado custo deste tipo de material. No Brasil, os estudos sobre o reprocessamento de cateteres de hemodinâmica são escassos. OBJETIVO: avaliar a prevalência do reprocessamento e em que condições ele é praticado na Cidade do Recife-PE. MÉTODO: trata-se de um estudo descritivo, do tipo transversal. A coleta dos dados foi realizada através de entrevista estruturada, utilizando-se um questionário contendo perguntas abertas e fechadas. RESULTADOS: foram avaliados quatro Hospitais da rede pública e seis da rede privada, na cidade do Recife. Foram 10 enfermeiros e 82 técnicos de enfermagem, que trabalhavam no setor de hemodinâmica. Todos os hospitais pesquisados reprocessam catéteres e apenas um deles realiza todas as etapas do reprocessamento na própria instituição; Na maioria das instituições os catéteres são reutilizados, em média, quatro vezes. Foi observada significativa divergência nas respostas fornecidas pelos enfermeiros e técnicos de enfermagem sobre parte dos itens avaliados, o que reflete a falta de padronização das técnicas utilizadas para reprocessar os catéteres. A maioria dos profissionais já detectou alterações nos cateteres reprocessados, sendo que as mais frequentes, fratura e tortuosidade. A preparação enzimática é utilizada por mais de 80% dos técnicos para a limpeza dos catéteres. Quanto aos procedimentos utilizados para a limpeza do lúmen, não houve uniformidade entre as respostas fornecidas pelos profissionais. Embora tenha sido verificado que a maioria dos profissionais utilize a água da torneira para enxaguar dos catéteres, a técnica utilizada é bastante diversificada. A maioria dos profissionais afirmou que testes para verificação de materiais pirogênicos não são executados em todos os materiais envolvidos, nas diversas etapas do reprocessamento. CONCLUSÕES: Todos os serviços avaliados reprocessam catéteres de hemodinâmica sem uma padronização e ou normatização
56

Comportamento do lactato sanguíneo no exercício resistido com a utilização da manga de compressão

Pedon, William Riciere January 2018 (has links)
Submitted by Gisely Teixeira (gisely.teixeira@uniceub.br) on 2018-06-11T18:03:40Z No. of bitstreams: 1 51400329.pdf: 1490055 bytes, checksum: 64acb5f2a1a505a01e46592878c78eb3 (MD5) / Made available in DSpace on 2018-06-11T18:03:40Z (GMT). No. of bitstreams: 1 51400329.pdf: 1490055 bytes, checksum: 64acb5f2a1a505a01e46592878c78eb3 (MD5) Previous issue date: 2018 / O estudo objetivou analisar de que forma se comporta o lactato sanguíneo em praticantes de musculação antes e após a realização de uma sessão aguda de exercício físico intenso com e sem a utilização da manga de compressão. O estudo contou com 16 voluntários praticantes de musculação da Academia Cia do Corpo de Inhumas-GO, com idade entre 20 a 30 anos, uma média de 26,08± 3,92 anos que realizarão o aquecimento especifico composto por uma série de 15 repetições com a carga aproximada de 50 % de 10RM. Apresentou uma média de 8,58± 0,99 escala de Omni-res. Foram executados os seguintes exercícios, flexão e extensão dos cotovelos rosca direta e tríceps no pulley ambos os exercícios foram executados com 3 séries de 10 RM, foi mantido a cadência de 2’’ na fase excêntrica e 2’’ na fase concêntrica. A concentração de lactato sanguíneo apresentou elevação significativa após o exercício intenso com a utilização da manga de compressão aos 05, 10, 15 e 20 minutos de recuperação. Aos cinco minutos Sem manga de compressão 9,43 ± 0,92 mmol/l; com a manga o resultado de 7,85 ± 2,09 mmol/l aos 10 minutos; Sem a manga de compressão 9,03±0,83 mmol/l; com a manga de compressão o resultado de 9,98± 2,35 mmol/l. Aos 15 minutos de repouso a coleta foi mensurada 10,48± 1,77 mmol/l com a manga de compressão em repouso o resultado foi de 6,05± 2,30 mmol/l; 20 minutos sem a manga de compressão foi 8,71± 1,17 mmol/l com a manga de compressão 4,32± 0,86 mmol/l. Conclusão: Conclui-se que houve diferença significativa no comportamento do lactato sanguíneo após a recuperação pós testes realizado no exercício resistido na utilização da manga de compressão gradual, nos períodos de repouso em 05, 10, 15 e 20 minutos. São necessários mais estudos nessa área com número maior de voluntários com sexo e idade diferente, para maiores contribuições acadêmicas neste sentido.
57

Estudo comparativo dos efeitos hemodinamicos da miocardiopatia diabetica e induzida por L-name em ratos / Hemodynamic effects of hypertensive-diabetc and L-name induced cardiomyopathy in rats : a comparative study

Gazzoto Filho, Ademir 05 August 2009 (has links)
Orientador: Heitor Moreno Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-13T16:25:53Z (GMT). No. of bitstreams: 1 GazzotoFilho_Ademir_M.pdf: 876670 bytes, checksum: e7b954abb9a6ffd97c187bf6ceadaa8a (MD5) Previous issue date: 2009 / Resumo: O óxido nítrico (NO) é um mediador biológico que atua como molécula chave em muitos processos fisiopatológicos, como a regulação do tônus vascular, neurotransmissão, aprendizado, memória, dentre outros. Por causa de sua importância e envolvimento nos mecanismos fisiológicos e patológicos, a sua regulação e síntese têm sido extensivamente estudadas. A inibição crônica do NO por administração via oral do inibidor inespecífico da NO-sintase, a nitro-L-arginina metil éster (L-NAME) resulta em cardiopatia hipertensiva em ratos. A hipertensão renovascular [dois rins e um clipe (2R1C)] e o diabetes melito (DM) associadas, induzem a anormalidades morfológicas semelhantes às descritas no modelo de cardiomiopatia induzida por L-NAME em ratos, mas seus efeitos hemodinâmicos ainda são controversos. O presente estudo avaliou a função cardíaca e vascular nestes dois modelos de cardiomiopatia após oito semanas de tratamento. Foram utilizados ratos Wistar, divididos em 5 Grupos: Grupo Controle; Grupo L-NAME: 60mg/kg/dia de L-NAME; Grupo 2R1C: com estenose cirúrgica de artéria renal para indução de hipertensão arterial renovascular; Grupo DM: animais que receberam estreptozotocina (60 mg/kg intra-venoso), Grupo 2R1C+DM: animais submetidos à cirurgia para indução de hipertensão arterial renovascular e que receberam estreptozotocina. Foram avaliados os seguintes parâmetros: pressão arterial média (PAM), débito cardíaco (DC), resistência vascular periférica total (RVPT), dP/dt positivo e dP/dt negativo em coração isolado. Em todos os grupos foram encontrados aumento na PAM, RVPT e redução do DC depois de oito semanas em relação ao Grupo Controle. Os grupos L-NAME e 2R1C+DM apresentaram aumento na PAM (175,4±29,7 e 158,7±16,7 mmHg, respectivamente) e redução do DC após a oitava semana. A RVPT aumentou em ambos os grupos. Uma diminuição da dP/dt positiva foi observada no grupo 2R1C+DM (1895±98 mmHg/s, p<0,05) vs. Grupo Controle (2534±120 mmHg/s, p<0,05). A dP/dt negativa diminuiu nos grupos L-NAME e 2R1C+DM vs. Grupo Controle (1490±104 e 1460±94 mmHg/s, respectivamente vs. 2080±92 mmHg/s, p<0,05). O presente estudo demonstrou que, apesar das semelhanças morfológicas entre os grupos 2R1C+DM e L-NAME, este último não mimetiza as alterações hemodinâmicas dos modelos diabético-hipertenso renovascular associados em ratos. / Abstract: Nitric oxide (NO) is a biological mediator that acts as a key molecule in many pathophysiological processes such as regulation of vascular tone, neurotransmission, learning, memory, and others. Because of its importance and involvement in physiological and pathological mechanisms, its regulation and synthesis have been extensively studied. Inhibition of NO by chronic oral administration of the nonspecific inhibitor of NO-synthase, the nitro-L-arginine methyl ester (L-NAME) results in hypertensive cardiomyopathy in rats. The renovascular hypertension [two kidneys and clip (2K1C)] and diabetes mellitus (DM) associated induce morphological abnormalities similar to those described in the model of cardiomyopathy induced by L-NAME in rats, but its hemodynamic effects are still controversial. This study evaluated the cardiac and vascular function in these two models of cardiomyopathy after eight weeks of treatment. We evaluate the following parameters: mean arterial pressure (MAP), cardiac output (CO), total total peripheral vascular resistance (TPVR), positive and negative dP/dt in isolated heart. In all groups were observed increased MAP, TPVR and reduced DC after eight weeks in the control group. Wistar rats were divided into the following groups: Control; L-NAME: 60mg/kg/day; 2K1C+DM: streptozotocin (60 mg/kg) and one renal artery clipped. The following parameters were measured: mean arterial pressure (MAP), heart rate, cardiac output (CO) and total peripheral vascular resistance (TPVR). Positive and negative dP/dt was also evaluated in an isolated heart. L-NAME and 2K1C+DM groups had increased MAP (175.4±29.7 and 158.7±16.7 mmHg, respectively) and reduced CO after the 8th week. TPVR was increased in both groups. A decrease in positive dP/dt was found in the 2K1C+DM (1895±98 mmHg/s, p<0.05) vs. Control group (2534±120 mmHg/s, p< 0.05). Negative dP/dt was decreased in the L-NAME and 2K1C+DM groups vs. Control group (1490±104 and 1460±94 mmHg/s, respectively vs. 2080±92 mmHg/s, p<0.05). Decrease in positive dP/dt 2R1C+DM group compared to Control. The negative dP/dt decreased in L-NAME and 2R1C+DM groups. This study demonstrated that despite the morphological similarities between 2K1C+DM and LNAME groups; the L-NAME group did not mimics the hemodynamic changes in hypertension n-diabetic- renovascular model associated in rats. / Mestrado / Mestre em Farmacologia
58

Metodologia para análise computacional de escoamento sanguíneo em dispositivos de assistência ventricular / Computational analyses methodology for blood flow in ventricular assist devices

Guilherme Barbosa Lopes Júnior 03 June 2016 (has links)
O avanço da bioengenharia atual tem sido motivado pela crescente necessidade da humanidade em se buscar formas para amenizar o sofrimento, garantir tempo para um tratamento, melhorar a qualidade de vida ou sanar quadros clínicos de pacientes. Assim, a crescente necessidade de órgãos artificiais impulsiona a área de bioengenharia para que seja dado um suporte no desenvolvimento destes mecanismos. Neste contexto se encontra o presente trabalho. Aqui, apresenta-se uma metodologia numérica para que seja aplicada a desenvolvimento e testes de Dispositivos de Assistência Cardíaca, de forma a otimizar o processo de desenvolvimento e estimar os possíveis problemas inerentes ao seu funcionamento. Compondo a metodologia, uma ampla discussão de cada etapa numérica foi elaborada, contribuindo para uma metodologia flexível para uma ampla variedade de aplicações. A hemólise também foi investigada através dos principais modelos da literatura, bem como foram propostos modelos adaptados para tentar estimar a hemólise verificada experimentalmente. Além das metodologias para cada etapa, uma metodologia geral utilizando Sistemas de Referências Múltiplas (SRM) compõe os resultados, para uma sequência de passos numéricos que possa obter resultados satisfatórios em comparação com resultados de bancada por loop test. Outros resultados encontrados e devidamente discutidos foram inerentes a uma densidade de malha a ser utilizada para que ocorra simulações com independência de malha, na qual uma densidade a partir de 318,43 elementos/mm³ para referenciais não-inerciais é proposta. O mapeamento da turbulência por seis modelos que aplicam a média de Reynolds também é discutido, indicando os melhores modelos a serem empregados para um número de Reynolds relativo (Re*) que relaciona a influência dos contornos nos resultados numéricos obtidos. Além disso, uma nova abordagem por tensão fisiológica é proposta para o cálculo da hemólise, sendo comparada aos modelos clássicos adotados. Os resultados para hemólise indicam um bom ajuste para o novo modelo proposto, bem como indica o correto tratamento de unidades para os modelos tradicionais. Por fim, as análises recaem na melhoria do dispositivo e conclui a metodologia numérica a ser empregada, preenchendo lacunas em cada etapa e determinando uma maneira de análise numérica cujos resultados são confiáveis. / The advance of current bioengineering has been driven by the increasing need of humanity to seek ways to alleviate the suffering, ensure time to treatment, improve the quality of life or cure medical conditions of patients. Thus, the growing need for artificial organs boosts bioengineering area to be given a support in the development of these mechanisms. In this context is the present work. Here, we present a numerical methodology to be applied to development and Cardiac Assist Devices tests in order to optimize the development process and estimate the potential problems inherent in their operation. Compounding the methodology, a comprehensive discussion of each numerical step was developed, contributing to a flexible methodology for a wide variety of applications. Hemolysis was also investigated through the main models of literature, and have been proposed models adapted to try to estimate hemolysis verified experimentally. In addition to the methodologies for each step, a general methodology using Multiple Reference Systems (MRF) makes up the results for a sequence of numeric steps you can get satisfactory results compared to bench test results for loop. Other findings were discussed and properly attached to a mesh density being used for simulations occurring independently mesh in which a density from 318.43 elements/mm³ Non-inertial frames is proposed. The mapping of turbulence six models applying Reynolds medium is also discussed, indicating the best designs to be employed for a number of relative Reynolds (Re*) that relates the influence of the contours of numerical results obtained. In addition, a new approach by physiological stress is proposed for the calculation of hemolysis, being compared to classic models adopted. The results for hemolysis indicate agreement with the proposed new model, and indicates the correct treatment units to the traditional models. The final analyses fall into improved device and completes the numerical methodology to be used by filling gaps in each step and determining a way to numerical analysis results which are dependable.
59

Avaliação hemodinâmica e respiratória em ovinos submetidos à sedação com xilazina ou dexmedetomidina antagonizada com atipamezole / Hemodynamic and respiratory evaluation in sheep submitted to sedation with xylazine or dexmedetomidine antagonized with atipamezol

Douglas do Carmo Alonso 09 August 2016 (has links)
Os agonistas alfa 2 adrenérgicos são sedativos empregados na rotina clínica de ruminantes, e têm, entre outras, a vantagem de possuir antagonistas específicos, que aumentam a segurança no uso destes medicamentos. Tendo em vista a escassez de estudos acerca dos parâmetros hemodinâmicos e respiratórios em ovinos em posição quadrupedal e submetidos à sedação com xilazina ou dexmedetomidina com posterior reversão pelo atipamezole, realizou-se o presente estudo. Para tanto, foram utilizados 12 ovinos, machos, com idade entre um e dois anos, peso médio de 37,7kg, distribuídos em dois grupos de seis animais que foram submetidos a dois tratamentos distintos com média de três semanas de intervalo, em estudo do tipo prospectivo, encoberto e aleatório, sendo designados como Grupo XILA (cloridrato de xilazina 0,2 mg/kg IM) e Grupo DEX (cloridrato de dexmedetomidina 15 &micro;g/kg IM). Para a instalação do cateter de artéria pulmonar os animais foram anestesiados com auxílio de máscara facial com isofluorano em oxigênio, e na sequência foram intubados e mantidos sob anestesia com o mesmo agente até o fim da instrumentação. Após a recuperação anestésica foram avaliados os parâmetros hemodinâmicos, hemogasométricos e respiratórios durante os primeiros 60 minutos com os animais em posição quadrupedal, para obtenção dos parâmetros basais. Finalizada esta avaliação, os animais foram submetidos aos protocolos de sedação segundo o seu grupo. Os parâmetros foram verificados e registrados aos cinco (S5), 15 (S15) e 30 minutos (S30) após sedação, e, após a aplicação de 30 &micro;g/kg IM de atipamezole aos cinco (R5) e 15 minutos (R15). Foram avaliados frequência e ritmo cardíaco, pressão arterial sistêmica, parâmetros hemodinâmicos, frequência respiratória, hemogasometria arterial e venosa mista, temperatura central, glicemia e grau de sedação. Os índices ventilatórios e hemodinâmicos foram calculados. O período de latência em XILA e DEX foram 3,9 e 5,2 minutos. A xilazina promoveu sedação mais intensa, com diferença significativa entre os grupos aos 5 e 15min após sedação (momentos S5 e S15). Após a sedação, observou-se redução significativa da frequência cardíaca nos dois grupos, que refletiu no débito cardíaco, índice cardíaco e pressão arterial média. Houve elevação não significativa da resistência vascular sistêmica em ambos os grupos, mas que após o atipamezole ficou significativamente mais baixa no grupo XILA. A xilazina causou taquipneia, que foi inibida após o atipamezole. Não houve alterações clinicamente importantes nos valores de PaCO2, PaO2, SaO2 e nem nos índices de ventilação, indicando que não ocorreu hipoxemia, hipercapnia ou hipoventilação durante a sedação. A glicemia elevou-se de maneira significativa nos dois grupos mantendo-se elevada mesmo após o antagonista. Após administração do atipamezole os animais levaram 10,0 e 11,7 minutos para ficarem em posição quadrupedal e 19,3 e 30 minutos para reversão dos efeitos da xilazina e da dexmedetomidina, respectivamente. Tanto a xilazina como a dexmedetomidina promoveram sedação segura, com poucos efeitos hemodinâmicos e cardiorrespiratórios, sugerindo que a administração pela via intramuscular seja adequada para sedação de ovinos com xilazina ou dexmedetomidina / Adrenergic alpha 2 agonists are sedatives used in ruminants clinical routine and have, among others, the advantage of specific antagonists which increase the safety of these drugs. Given the scarcity of studies on the hemodynamic and respiratory parameters in sheep in standing position and undergoing sedation with xylazine or dexmedetomidine with subsequent reversal by atipamezol, this study was performed. For this purpose were used 12 male sheep, aged between one and two years, average weight 37,7kg. Sheep were divided into two groups of six animals that were submitted to two different treatments with a mean interval of three weeks, in a study of prospective hidden and random type, being designated as XILA Group (xylazine hydrochloride 0.2 mg/kg) and DEX Group (dexmedetomidine hydrochloride 15 &micro;g/kg) given by intramuscular route. For the installation of pulmonary artery catheter, the animals were anesthetized with facial mask with isofluorane in oxygen, and were intubated and maintained under anesthesia with the same agent until the end of instrumentation. After recovery of anesthesia, we evaluated the hemodynamic, blood gas and respiratory parameters during the first 60 minutes with animals in standing position, to obtain the baseline parameters. Completed this evaluation, the animals were submitted to sedation protocols according to their group. The parameters were checked and registered to 5 (S5), 15 (S15) and 30 minutes (S30) after sedation, and after application of 30 &micro;g/kg atipamezole by intramuscular route to 5 (R5) and 15 minutes (R15). Frequency and heart rate, systemic blood pressure, hemodynamic parameters, respiratory rate, arterial and mixed venous blood gas analysis, core temperature, blood glucose and degree of sedation were evaluated. Ventilatory and hemodynamic indices were calculated. The onset period in XILA and DEX were 3.9 and 5.2 minutes. Xylazine promoted more intense sedation, with a significant difference between the groups at 5 and 15 minutes after alpha 2 administration (S5 and S15). After sedation, significant decrease in heart rate was observed in both groups, which reflected in cardiac output, cardiac index and mean arterial pressure. There was no significant increase in systemic vascular resistance in both groups, but after atipamezol was significantly lower in the XILA group. Xylazine caused tachypnea, which was inhibited after atipamezol. There were no clinically significant changes in PaCO2, PaO2, SaO2 nor in the ventilation indices, indicating that there was no hypoxemia, hypercapnia or hypoventilation during sedation period. Blood glucose rose significantly in both groups, remained higher even after antagonist. After administration of atipamezol sheep needed 10.0 and 11.7 minutes to remain in standing position and 19.3 and 30 minutes to reverse the effects of dexmedetomidine and xylazine, respectively. Xylazine and dexmedetomidine promoted safe sedation with few hemodynamic and cardiorespiratory effects, suggesting that the intramuscularly route is suitable for sedation of sheep with xylazine or dexmedetomidine
60

Correlação entre ansiedade e dor com a pressão arterial e a frequencia cardiaca durante o atendimento odontologico de urgencias

Rodrigues, Rodrigo Ventura 30 January 2004 (has links)
Orientador: Jose Ranali / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T21:52:16Z (GMT). No. of bitstreams: 1 Rodrigues_RodrigoVentura_M.pdf: 301241 bytes, checksum: d514c81d282fc431e00d567e0748f4ce (MD5) Previous issue date: 2004 / Resumo: Este trabalho avaliou a influência da dor e da ansiedade sobre a pressão arterial de pacientes que compareceram no Plantão de Urgências da Faculdade de Odontologia de Piracicaba/UNICAMP. Foram selecionados, de forma aleatória, 139 voluntários. Características populacionais como gênero, idade e nível cultural também foram avaliados. Enquanto aguardavam na sala de espera, os voluntários foram submetidos à Escala de Ansiedade Odontológica de Corah (EAO). Além disso, para avaliar a dor com que os voluntários chegavam ao plantão de urgências, foi aplicada uma Escala Analógica Visual (EAV) antes do atendimento. A pressão arterial (PA) e a freqüência cardíaca (FC) foram avaliadas em 5 momentos distintos: a) a inicial, com o paciente na sala de espera; b) na cadeira odontológica, porém antes do atendimento; c) logo após a aplicação do anestésico local; d) dez minutos após a aplicação do anestésico local; e) ao término do atendimento. Todas as coletas de dados e aferições da PA e da FC foram realizadas por um único avaliador, o qual não teve nenhuma participação no atendimento odontológico realizado pelos alunos de graduação. Todos os dados foram submetidos ao teste de Kruskal-Wallis, Friedman ou Mann-Whitney. Os resultados revelaram que a ansiedade e a dor não foram afetadas pela idade, entretanto a primeira foi relacionada ao gênero (p<0,05). O nível de atenção ao paciente não foi influenciado pelo grau de ansiedade que o mesmo apresentava (p>0,05). Além disso, foi observada relação entre relatar a dor, exibir ansiedade e demonstrar dor com o nível de ansiedade. Entretanto, o nível de ansiedade exibido pelo paciente não foi levado em consideração para a adoção de medidas de controle da mesma. Embora os anestésicos locais contendo adrenalina tenham sido os mais utilizados para técnicas anestésicas, a prática da aspiração não foi comum (p<0,05). Os parâmetros cardiovasculares avaliados no decorrer do atendimento odontológico não foram afetados pelo grau de ansiedade e dor, medidos previamente à sessão (p>0,05) / Abstract: The purpose of this study was to evaluate the influence of pain and anxiety over the blood pressure of patients during emergency situations, whose were attended in the Dental Emergency Service of Piracicaba Dental School. One hundred and thirty nine volunteers were selected. Populational factors like gender, age and instruction degree were verified. During waiting for the treatment, these patients were submitted to the Anxiety¿s Dental Scale of Corah in order to establish the degree of anxiety and to a Visual Analogue Scale to evaluate the pain degree before the dental treatment. The blood pressure and cardiac frequency (CF) were evaluated at five different moments: a) first: patient at the waiting room; b) at the dental chair (before the treatment); c) after the local anesthesia; d) ten minutes after anesthesia; and e) at the end of the treatment. Also, the execution of aspiration prior anesthesia, the kind of anesthesia and the anesthetic used were evaluated. All measurements were performed by the same examiner, which did not execute any dental procedure. The data were submitted to Kruskal-Wallis, Friedman or Mann-Whitney tests. The results showed that the anxiety and pain were not affected by age, but anxiety is affected by the patient¿s gender (p<0.05). The anxious patients did not receive more attention from the operator than the non anxious ones (p>0.05). Also, it was not observed relationship between anxiety degree (Corah scale) and pain or anxiety related by patients. The anxiety degree was not considered by the operator in order to adopt anxiety control procedures. The local anesthetics with epinephrine and blocking injections were the most used, but aspiration was not usual (p<0.05). The cardiovascular parameters (CF and blood pressure) were not affected by the initial anxiety and pain degrees (p>0.05) / Mestrado / Farmacologia, Anestesiologia e Terapeutica / Mestre em Odontologia

Page generated in 0.0651 seconds