• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 26
  • 3
  • 1
  • Tagged with
  • 31
  • 22
  • 13
  • 10
  • 9
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Variação da pressão sistólica como indicadora precoce de hipovolemia e guia de reposição volêmica com solução hiperosmótica e hiperoncótica no cão

Paiva Filho, Odilar [UNESP] January 2001 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:21Z (GMT). No. of bitstreams: 0 Previous issue date: 2001Bitstream added on 2014-06-13T19:27:33Z : No. of bitstreams: 1 paivafilho_o_me_botfm.pdf: 504699 bytes, checksum: 1172b273f934761c359be9d53a5db958 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A detecção da hipovolemia insidiosa no intra-operatório é difícil devido a pouca especificidade dos sinais clínicos e hemodinâmicos. Estudos introduziram um novo método para avaliação da pré-carga, baseados na análise da variação da pressão sistólica (VPS) durante a ventilação mecânica. O presente estudo tem por objetivo avaliar se a VPS e sua derivada delta down (ddown) são indicadoras precoces de hipovolemia e guias de reposição volêmica com solução hiperosmótica e hiperoncótica no cão anestesiado submetido a hipovolemia. Doze cães sem raça definida, anestesiados com propofol, fentanil, rocurônio e isoflurano, e esplenectomizados, foram submetidos a sangramentos parciais de 5% da volemia até se atingir a retirada total de 20% da volemia (14 ml.kg-1). Após cada momento foram realizadas análises hemodinâmicas, respiratórias e sangüíneas. Em seguida, os cães foram submetidos à reposição volêmica com solução de NaCl a 7,5% em dextran 70 a 3,75% (4 ml.kg-1) em 10 minutos e novas análises foram realizadas aos 5 e 30 minutos após a reposição volêmica. A freqüência cardíaca não apresentou alteração... / The insidious hypovolemia detection in the intraoperative is difficult due to little specificity of clinical and hemodynamic signs. Studies introduced a new method for preload evaluation, based on systolic pressure variation analysis (SPV) during mechanical ventilation. The present study aims to evaluate if SPV and its derived delta down (ddown) are early indicator of hypovolemia, and guides of volemic replacement with hyperosmotic and hyperoncotic solution in anesthetized dogs submitted to hypovolemia. Twelve mogrel dogs, anesthetized with propofol, fentanyl, rocuronium and isoflurane, were submitted to graded haemorrhage of 5% of its volemia to reach the total of 20% of volemia (14 ml.kg-1). After every haemorrhage period, hemodynamic, ventilatory and blood atributes were studied. Imediately after, the dogs were submitted to volemic replacement with 7.5% NaCl solution in 3,75% dextran 70 (4 ml.kg-1) in 10 minutes, and the atributes were studied after 5 and 30 minutes following the volemic replacement. Heart rate was not changed significantly. Mean arterial pressure decreased significantly during haemorrhage, and increased... (Complete abstract, click electronic access below)
2

Variação da pressão sistólica como indicadora precoce de hipovolemia e guia de reposição volêmica com solução hiperosmótica e hiperoncótica no cão /

Paiva Filho, Odilar January 2001 (has links)
Orientador: José Reinaldo Cerqueira Braz / Resumo: A detecção da hipovolemia insidiosa no intra-operatório é difícil devido a pouca especificidade dos sinais clínicos e hemodinâmicos. Estudos introduziram um novo método para avaliação da pré-carga, baseados na análise da variação da pressão sistólica (VPS) durante a ventilação mecânica. O presente estudo tem por objetivo avaliar se a VPS e sua derivada delta down (ddown) são indicadoras precoces de hipovolemia e guias de reposição volêmica com solução hiperosmótica e hiperoncótica no cão anestesiado submetido a hipovolemia. Doze cães sem raça definida, anestesiados com propofol, fentanil, rocurônio e isoflurano, e esplenectomizados, foram submetidos a sangramentos parciais de 5% da volemia até se atingir a retirada total de 20% da volemia (14 ml.kg-1). Após cada momento foram realizadas análises hemodinâmicas, respiratórias e sangüíneas. Em seguida, os cães foram submetidos à reposição volêmica com solução de NaCl a 7,5% em dextran 70 a 3,75% (4 ml.kg-1) em 10 minutos e novas análises foram realizadas aos 5 e 30 minutos após a reposição volêmica. A freqüência cardíaca não apresentou alteração... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The insidious hypovolemia detection in the intraoperative is difficult due to little specificity of clinical and hemodynamic signs. Studies introduced a new method for preload evaluation, based on systolic pressure variation analysis (SPV) during mechanical ventilation. The present study aims to evaluate if SPV and its derived delta down (ddown) are early indicator of hypovolemia, and guides of volemic replacement with hyperosmotic and hyperoncotic solution in anesthetized dogs submitted to hypovolemia. Twelve mogrel dogs, anesthetized with propofol, fentanyl, rocuronium and isoflurane, were submitted to graded haemorrhage of 5% of its volemia to reach the total of 20% of volemia (14 ml.kg-1). After every haemorrhage period, hemodynamic, ventilatory and blood atributes were studied. Imediately after, the dogs were submitted to volemic replacement with 7.5% NaCl solution in 3,75% dextran 70 (4 ml.kg-1) in 10 minutes, and the atributes were studied after 5 and 30 minutes following the volemic replacement. Heart rate was not changed significantly. Mean arterial pressure decreased significantly during haemorrhage, and increased... (Complete abstract, click electronic access below) / Mestre
3

Influencia do choque hemorragico na anastomose de colon sigmoide em ratos : avaliação com teste de resistencia a pressão de ruptura / Hemorrhagic shock influence on colonic anastomosis in rats : Evaluation with resistence test to rupture by liquid distension

Pereira, Yara Emantne Amaral 20 June 2007 (has links)
Orientadores: Claudio Saddy Rodrigues Coy, João Jose Fagundes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-09T01:10:44Z (GMT). No. of bitstreams: 1 Pereira_YaraEmantneAmaral_M.pdf: 1682869 bytes, checksum: 9d5801f67ab43156ce97cd3a10778b4d (MD5) Previous issue date: 2007 / Resumo: Introdução: As complicações das anastomoses intestinais podem ser graves com altos índices de morbi/mortalidade. Vários fatores relacionados à qualidade das mesmas têm sido objetos de estudos, como técnica operatória, fios de sutura ou variáveis bioquímicas, enquanto que outros, não associados diretamente à técnica cirúrgica, são menos avaliados, como por exemplo, a influência de choque hemorrágico. Objetivo: Avaliar o efeito do choque hemorrágico em anastomoses de cólon em ratos, com teste de ruptura à distensão por líquido. Material e Método: Foram utilizados ratos da linhagem Wistar, com idade aproximada de 90 dias e peso variando de 310 gramas a 380 gramas. Os animais foram divididos em dois grupos, sendo o grupo G1, composto por 10 animais submetidos à anastomose de cólon em condições de normovolemia e o grupo G2, composto por 10 animais submetidos à anastomose de cólon em condições de hipovolemia. O choque foi instalado através da retirada de meio mililitro de sangue a cada dois minutos, até que se atingissem valores de pressão arterial média (PAM) de 50mmHg ou volume total de retirada correspondente a 30% da volemia. Foram realizadas dosagens séricas de lactato (mmol/l) no início do procedimento e ao término do mesmo. Os valores séricos médios de lactato ao término da cirurgia foram de 1,91 mMol/l no grupo G1 e de 3,69 mMol/l no grupo G2 (p<0,05) No quinto dia de pós-operatório, os animais foram submetidos à eutanásia e tiveram suas anastomoses testadas por teste de resistência à pressão de ruptura à distensão por líquido. Resultados: No grupo G1, o valor médio da pressão de ruptura do cólon à distensão por líquido foi de 160,7 mmHg enquanto que no grupo G2 foi de 152,1mmHg (p>0,05). Conclusão: A presença de choque hemorrágico, nas condições estabelecidas neste estudo, não exerceu influência em anastomoses de cólon em ratos, avaliadas com teste de ruptura à distensão por líquido / Abstract: Introduction: Intestinal anastomoses complications can be very serious, with high morbidity and mortality rates. Several factors related to their quality have been object of studies, such as technical aspects, suture threads or biochemical variables. Others, not directly associated with the surgery technique, are less evaluated, such as the influence of hemorrhagic shock. Objective: Evaluate the effect of hemorrhagic shock in colonic anastomoses in rats, with resistance test to rupture by liquid distension. Methods and Material: Wistar lineage rats, averaging 90 days old and weight varying from 310 to 380 grams were divided into two groups. In the G1 group, 10 animals were submitted to colonic anastomoses in normovolemic terms and the G2 group 10 animals were submitted to colonic anastomoses in hipovolemic conditions. The shock was caused by half milliliter blood withdrawal, done every two minutes, until reached the value of average arterial pressure of 50mmHg or total volume of corresponding withdrawal to 30% of volemia. Serum lactate dosages were carried out at the beginning and at the end of the procedure. The average serum values lactate at the end of the surgery were 1,91 mMol/l in the G1 group and 3,69 mMol/l in the G2 group (p<0,05). On the fifth postoperative day, the animals were submitted to euthanasia. The anastomoses were evaluated with resistance test to rupture by liquid distension. Results: In the G1 group, the average value of colonic rupture was 160,7mmHg whereas in the G2 group was 152,1mmHg (p>0,05). Conclusion: Hemorrhagic shock, in the established conditions of this study, had no influence in colonic anastomosis in rats evaluated with resistance test to rupture by liquid distention / Mestrado / Cirurgia / Mestre em Cirurgia
4

The Effects of a Hydration Intervention on Cardiac Function, Autonomic Activity, and Cerebral Oxygenation during Phlebotomy

Scanlin, Matthew C. 25 August 2015 (has links)
No description available.
5

Hipertoninio hidroksietilkrakmolo tirpalo įtaka hemodinamikai, kvėpavimui ir homeostazei koreguojant hipovolemiją ligoniams po širdies operacijų / The effect of hypertonic Hydroxyethyl starch solution On haemodynamics, respiration And homeostasis in correction Of hypovolemia in patients After heart surgery

Šneider, Edvin 23 September 2005 (has links)
Conclusions 1. In comparison to the Ringer‘s acetate solution the use of HyperHaes® solution after coronary artery bypass surgery had positive effect on haemodynamic parameters: cardiac index increased (p<0.05), systolic volume index increased (p<0.05), cardiac afterload decreased, that is pulmonary vascular resistance index decreased (p<0.05) and systemic vascular resistance index decreased (p<0.05); the difference between the central and peripheral temperatures in experimental group (p<0.05). 2. The oxygen transport was more effective (oxygen delivery index increased (p<0.05)) when HyperHaes® solution was used in comparison to Ringer‘s acetate solution. 3. No substantial effect of HyperHaes® solution on the duration of artificial lung ventilation and intrapulmonary shunt size was defined. 4. The use of HyperHaes® solution influenced substantially some parameters of homeostasis (serum sodium concentration increased (p<0.05), serum potassium concentration decreased (p<0.05)) in compa-rison to Ringer‘s acetate solution. 5. Higher diuresis (p<0.01), lower need for the infusion therapy for the first 24 hours (p<0.05), lower total fluid balance (p<0.01) were determined in HyperHaes® group versus Ringer‘s acetate group. 6. No adverse effects (disturbances of homeostasis, neurologic symptoms, increased bleeding through mediastinal tubes, anaphylactic reactions) were noted in patients who received HyperHaes® solution.
6

Toward Optimal Adaptive Control of Hemodialysis

Hemasilpin, Nat 16 September 2013 (has links)
No description available.
7

Avaliação hemodinâmica, metabólica e do transporte de oxigênio durante anestesia com xenônio em cães hipovolêmicos / Haemodynamic, metabolic and oxygen delivery evaluation during xenon anesthesia in hypovolemic dogs

Franceschi, Ruben Carvalho 10 October 2006 (has links)
Justificativa e Objetivos - A indução anestésica em indivíduos em choque hipovolêmico pode agravar a instabilidade hemodinâmica. O anestésico inalatório xenônio (Xe) é gás inerte com propriedades que mantêm a estabilidade hemodinâmica, durante a anestesia, em individuos normais. O objetivo deste estudo foi avaliar os efeitos hemodinâmicos, metabólicos e sobre o transporte de oxigênio, durante anestesia com Xe, em cães submetidos a choque hipovolêmico. Método - Vinte e um cães sem raça definida foram submetidos a hipnose e relaxamento muscular por infusão venosa contínua de etomidato e vecurônio e ventilação controlada mecânica com FiO2 21% (oxigênio + ar comprimido). Sob anestesia local, inseriu-se cateter em artéria pulmonar para monitorização hemodinâmica e cateteres em artérias femorais direita e esquerda para medida da pressão arterial média e indução do choque hipovolêmico. Após indução do choque hemorrágico até a pressão arterial média atingir 40mmHg por 2 minutos, os animais foram randomizados em grupos controle e xenônio. O grupo xenônio recebeu ventilação controlada mecânica com O2 21% + Xe 79% durante 20 min. Realizou-se coleta de gasometria arterial e venosa mista e coleta de dados hemodinâmicos, com posterior cálculo hemodinâmico e do transporte de O2 antes da indução do choque, imediatamente após a sangria, após 5 min e 20 min, com administração de Xe, e 20 minutos após a suspensão do Xe. O grupo controle foi submetido ao mesmo procedimento, sem a administração de Xe. Os dois grupos foram comparados, utilizando análise de variância para medidas repetidas, considerando-se significativo p<0,05. Resultados: Os grupos foram comparáveis em relação aos valores médios de peso corpóreo e volume de sangramento. As variáveis hemodinâmicas, metabólicas e de transporte de oxigênio não apresentaram diferenças significativas entre os grupos controle e xenônio. Após a indução do choque, no grupo Xe a freqüência cardíaca variou de 130,22±20,57 para 131,89±24,34 em 5min e 138,44±33,66 após 20 minutos. No grupo controle esta variação foi de 144,33±21,03 para 143,75±22,58 após 5min (p=0,82) e para 149,50±23,52 após 20min(p=0,16). Conclusão: A administração de xenônio em cães, em estado de choque hipovolêmico, não altera a condição hemodinâmica, metabólica e de transporte de oxigênio, permitindo sugeri-lo como anestésico seguro em individuos nestas condições / Rationale and objectives - Anesthesia induction in subjects with hypovolemic shock may worsen a baseline hemodynamic instability. Xenon (Xe), an inhalation anesthetics, is an inactive gas with properties that, in normal subjects, maintain hemodynamic stability during anesthesia. The aim of this study was to assess Xe effects on hemodynamics, metabolism, and oxygen delivery during anesthesia in dogs with induced hypovolemic shock. Method - Twenty-one hybrid dogs were submitted to hypnosis and muscle relaxation by continuous venous infusion of etomidate and vecuronium and mechanichal controlled ventilation with a 21% FiO2 (oxigen + compressed air). Under local anesthesia, catheters were introduced into the pulmonary artery for hemodynamic monitoring, and in the left and right femoral arteries for mean arterial blood pressure measurements and hypovolemic shock induction. After induction of an hemorrhagic shock until a mean arterial blood pressure of 40mmHg for 2 minutes was reached, the animals were randomized into the Xenon or the control group. Dogs from the Xenon group received controlled mechanichal ventilation with a 21% FiO2 + 79% Xe for 20 minutes. Blood samples were collected for arterial e mixed venous gas analyses; hemodynamic data were also collected, with further hemodynamic calculation of O2 delivery before shock induction, immediately after the artificial bleeding, 5 min and 20 minutes after starting Xe administration, and 20 minutes after stopping Xe. The control group was submitted to the same procedures, without Xe administration. Both groups were compared using variance analysis for repeated measurements, considering statistical significance where a p<0,05 was reached. Results: Both groups were comparable in terms of mean body weight values and bleeding volume. Hemodynamic and metabolic variables and oxygen delviery had no significant differences between both groups, control and Xenon. In the Xenon group, after shock was induced, heart rate changed from 130.22 ± 20.57 to 131.89 ± 24.34 after 5 minutes, and to 138.44 ± 33.66 after 20 minutes. In the control group, heart rate varied from 144.33 ± 21.03 to 143.75 ± 22.58 after 5 minutes (p=0.82), and to 149.50 ± 23.52 after 20 minutes (p=0.16). Conclusion: Xenon administration does not cause changes in hemodynamics, metabolism, and oxygen delivery in dogs with induced hypovolemic shock, supporting its recommendation as a safe anesthetic in such conditions
8

Transfusão de sangue obtido de doadores anestesiados com cetamina e xilazina ou isoflurano em gatos hipovolêmicos / Blood transfusion obtained from donors anesthetized whit ketamine and xylazine or isoflurane in hypovolemic cats

Cartana, Camila Basso 17 March 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Blood transfusions are an important component of critical care. Obtaining blood for transfusion in cats is challenging due to its restless temperament, which makes unusual donors that do not require anesthesia during collection. Some anesthetic protocols have been recommended for cats donors. However, there are no studies about the possible consequences of the presence of anesthetics in blood transfused to hypovolemic recipients. The aims of this study are: to evaluate and compare the responses of hypovolemic cats to transfusion from blood donors anesthetized by isoflurane or combination of ketamine and xylazin; and evaluate a technique for monitoring arterial and venous blood pressures by dissecation and catheterization of carotid artery and jugular vein. We used 10 adult cats, mixed breed, weighing between 3 and 4.5kg. The animals integrated two groups: ISO (five donors and five recipients of blood collected under anesthesia by isoflurane) and CX (five donors and five recipients of blood collected under anesthesia by the combination of ketamine and xylazine). After anesthetic induction of the donor by one of the protocols, the blood was collected. The recipients were anesthetized with isoflurane and atracurium, and maintained on mechanical ventilation. The baseline data (t0) were measured by the following parameters: respiratory rate (RR), expired anesthetic concentration (ETIS), end-tidal carbon dioxide (ETCO2), central venous pressure (CVP), systolic, diastolic and mean blood pressure (SBP, DBP and MBP), heart rate (HR), arterial blood gas, blood count, glucose, urea and creatinine. The recipients had the hypovolemia induced by withdrawal of 20ml kg-1 of blood and then received blood from donors. The measurements were performed at baseline (t0), after hypovolemia (t1), immediately, 15, 30, 45 and 60 minutes after transfusion (t2, t3, t4, t5 and t6), and laboratory tests carried out only on t0, t1, t2 and t6. Data were subjected to analysis of one-way with multiple repetitions (ANOVA) followed by comparison by Tukey test to determine the statistical differences between means over the time in each group, as well as the means of each time between the groups. Differences were considered statistically significant when P ≤ 0.05. The group CX presented CVP significantly higher than the ISO group after transfusion and in the times following. Also were observed more stable values of SBP, DBP and MAP in CX group over the time, while the ISO group showed a decline of these parameters after hypovolemia. Except for PVC, there was no difference between the anesthetic protocols about the effects on cardiovascular function and blood count, chemistry and gas analysis of the recipients. Blood transfusion from donor anesthetized with ketamine and xylazine caused greater increase of the PVC of the recipients, when compared to transfusion of blood collected under anesthesia with isoflurane. It wasn t possible to establish an effective comparison between the protocols evaluated. Additional studies with larger number of animals and evidence of the presence of anesthetics in blood transfusions could clarify this issue. The proposed technique allowed to monitor effectively the arterial and venous blood pressures, although the risk of bleeding from accidental loss of the arterial catheter. / Transfusões sangüíneas constituem importante recurso de terapia intensiva. A obtenção de sangue para transfusão em gatos é desafiadora, em função de seu temperamento caracteristicamente indócil, que torna incomum a disponibilidade de doadores que não exijam anestesia durante a coleta. Alguns protocolos anestésicos têm sido recomendados para gatos doadores. No entanto, desconhecem-se estudos acerca das possíveis conseqüências da presença de anestésicos no sangue transfundido em receptores hipovolêmicos. Os objetivos deste estudo são: avaliar e comparar as respostas de gatos hipovolêmicos à transfusão de sangue de doadores anestesiados por isoflurano ou associação de cetamina e xilazina; e avaliar uma técnica de monitoração das pressões arterial e venosa por meio de dissecação e cateterização carotídea e jugular. Foram utilizados 10 gatos adultos, sem raça definida, pesando entre 3 e 4,5kg. Os animais integraram dois grupos: ISO (cinco doadores e cinco receptores de sangue coletado sob anestesia por isoflurano) e CX (cinco doadores e cinco receptores de sangue coletado sob anestesia pela associação de cetamina e xilazina). Após indução anestésica dos doadores por um dos protocolos propostos, procedeu-se a coleta do sangue. Os receptores foram anestesiados com isoflurano e atracúrio, e mantidos sob ventilação mecânica. Aferiram-se os dados basais (t0) dos parâmetros: freqüência respiratória (f), concentração de anestésico expirado (ETiso), tensão de dióxido de carbono ao final da expiração (ETCO2), pressão venosa central (PVC), pressões arteriais sistólica, diastólica e média (PAS, PAD e PAM), freqüência cardíaca (FC), hemogasometria arterial; hemograma, glicose, uréia e creatinina. Os receptores foram induzidos à hipovolemia pela retirada de 20ml kg-1 de sangue e, em seguida, receberam o sangue dos doadores. As aferições foram realizadas no período basal (t0), após a hipovolemia (t1), imediatamente, 15, 30, 45 e 60 minutos após a transfusão (t2, t3, t4, t5 e t6), sendo os exames laboratoriais realizados apenas em t0, t1, t2 e t6. Os dados foram submetidos à análise de variância de uma via com repetições múltiplas (ANOVA), seguidas de comparação pelo teste de Tukey, para determinação das diferenças estatísticas entre médias ao longo do tempo em cada grupo, e as médias em cada tempo entre grupos. As diferenças foram consideradas estatisticamente significativas quando P≤0,05. O grupo CX apresentou valores de PVC significativamente maiores que os do grupo ISO após a transfusão e nos tempos seguintes. Também observaram-se valores mais estáveis de PAS, PAD e PAM no grupo CX ao longo do tempo, enquanto o grupo ISO apresentou queda significativa desses parâmetros após a hipovolemia. Com exceção da PVC, não houve diferença entre os protocolos em relação aos efeitos sobre a função cardiovascular e os dados de hemograma, bioquímica sérica e hemogasometria dos receptores. A transfusão de sangue de doadores anestesiados com cetamina e xilazina promoveu maior elevação da PVC nos receptores, quando comparada à transfusão de sangue coletado sob anestesia com isoflurano. Não foi possível estabelecer uma comparação efetiva entre os protocolos avaliados. Estudos adicionais, com maior número de animais e provas comprobatórias da presença dos fármacos no sangue transfundido poderiam contribuir para o esclarecimento dessa questão. A técnica de proposta permitiu monitorar satisfatoriamente as pressões arterial e venosa central, apesar do risco de hemorragia por perda acidental do cateter arterial.
9

Respostas à perda sanguínea aguda em caprinos / Responses to acute blood loss in goats

Argolo, Erick Paiva de 28 February 2014 (has links)
Made available in DSpace on 2016-08-15T20:31:16Z (GMT). No. of bitstreams: 1 ErickPA_DISSERT.pdf: 4061592 bytes, checksum: 7e51a0e203a6b0a661e28e6402acf1cf (MD5) Previous issue date: 2014-02-28 / The present study aimed to evaluate the effects of acute blood loss in goats, due to the removal of 30% of blood volume. Eight mixed-breed, castrated, adult, healthy goats were used, weighing on average 34.75 + 4.3 kg. Clinical, hemogasometrical, hematological, and biochemical parameters were evaluated; as well as systolic, diastolic and mean blood pressure at the following moments: T0, before sampling, T1, T6, T12, T24, and T72, took place one, six, 12, 24, and 72 hours after sampling, respectively; and T8d, T16d, T24d and T32d, took place eight, 16, 24 and 32 days after sampling. From the total volume of blood 30% were taken. The goats presented tachycardia and tachypnea after the blood removal, a temporary rise in temperature occurred one hour after sampling, returning to normal values already in T6h. Packed cell volume decreased from T1h until T12h. The number of red blood cells, however, was different when compared to T0 only after T12h. Total protein and albumin levels were inferior when compared T0 only an hour after a blood loss, and remained as such until T16d and T8d, respectively. The CRT was high in T1h when compared to T0, but no difference was observed when compared to T12h. There was a decrease in serum calcium levels from T1h up until T24h. Glucose rose in T1h until T6h. At T1h, pH, TCO2, bicarbonate values and base deficit were smaller when compared to T0, while the lactate levels markedly increased at this time. The pO2 and SO2 were not altered. The pCO2 presented decreased values only at T24h. Systolic, diastolic and mean blood pressures showed, immediately after sampling, values lower than half of the observed at T0, however there was no difference at T1h. The concentrations of AST, GGT, urea and creatinine remained within the reference range. The acute loss of 30% of blood volume in goats causes noticeable changes in the clinical, hematological, hemogasometrical, and cardiovascular parameters / O presente estudo objetivou avaliar os efeitos da perda sanguínea aguda em caprinos, com a retirada de 30% do volume sanguíneo. Utilizou-se oito caprinos, SRD, machos, castrados, adultos, hígidos, pesando em media 34,75 + 4,3 kg. Foram avaliados parâmetros clínicos, hemogasométricos, hematológicos, bioquímicos; e pressões sistólica, diastólica e média nos tempos a seguir: T0, antes da coleta, T1, T6, T12, T24, T72, uma, seis, 12, 24, 72 horas após a coleta, respectivamente; e T8d, 16d, 24d e 32d, oito, 16, 24 e 32 dias após a coleta. Foram retirados 30% do volume total de sangue. Houve taquicardia e taquipnéia após retirada de sangue, elevação temporária da temperatura uma hora pós-coleta, voltando a valores normais já no T6h. O volume globular mostrou queda a partir do T1h até o T12h. Já o número de hemácias apresentou diferença em relação ao T0 somente a partir do T12h. A proteína total e albumina mostraram-se inferiores em relação T0 uma hora pós-perda sanguínea, mantendo-se até os tempos T16d e T8d respectivamente. O TPC mostrou-se elevado no T1h em relação ao T0, mas sem diferença em relação ao mesmo no T12h. Observou-se diminuição da concentração sérica do cálcio a partir do T1h até T24h. A glicose elevou-se no T1h até o T6h. No T1h os valores de pH, TCO2, bicarbonato e déficit de base mostraram-se menores em relação ao T0, enquanto o teor de lactato elevou-se marcadamente neste tempo. A pO2 e a SO2 não se alteraram. A pCO2 apresentou menores valores apenas no T24h. As pressões sistólicas, diastólicas e média mostraram imediatamente após a coleta, valores inferiores à metade do observado no T0, porém sem mostrar diferença em relação a este no T1h. As concentrações de AST, GGT, ureia e creatinina, mantiveram-se dentro dos valores de referência. A perda aguda de 30% do volume sanguíneo em caprinos provoca alterações visíveis nos parâmetros clínicos, hematológicos, hemogasométricos e cardiovasculares
10

Estudo comparativo entre as ventilações espontânea, mandatória intermitente sincronizada, pressão de suporte e volume garantido e suporte pressórico, em coelhos anestesiados com propofol e induzidos à hipovolemia aguda

Batista, Priscila Andrea Costa dos Santos [UNESP] 20 June 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:09Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-06-20Bitstream added on 2014-06-13T20:41:26Z : No. of bitstreams: 1 batista_pacs_dr_jabo.pdf: 1010587 bytes, checksum: 02a7bf064302a3fb5658ae96cde626bf (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Avaliaram-se os efeitos das ventilações espontânea, mandatória intermitente sincronizada (SIMV), pressão de suporte e volume garantido (VAPSV) e suporte pressórico (VPS) sobre as variáveis hemogasométricas, cardiovasculares e da dinâmica respiratória em coelhos anestesiados com infusão contínua de propofol e submetidos à hipovolemia aguda. Para tal, foram utilizados 40 coelhos, da raça Nova Zelândia, os quais foram distribuídos em quatro grupos, sendo denominados GE (ventilação espontânea), GM (SIMV), GP (VPS) e GV (VAPSV). Na medicação préanestésica foi administrado cetamina (15 mg/kg) e xilazina (1 mg/kg) pela via intramuscular. O propofol foi empregado na indução (8mg/kg) e na manutenção anestésica (0,5 mg/kg/min). Decorridos 40 minutos da indução, os animais foram induzidos à hipovolemia por meio da retirada de sangue arterial (12 mL/kg). Os parâmetros foram mensurados 40 minutos após a indução anestésica (M0), seguido de novas mensurações a cada dez minutos depois da hipovolemia (de M1a M6). O método estatístico utilizado foi o quadrado mínimo, utilizando o programa computacional SAS. Em relação às variáveis cardiovasculares, as médias de débito cardíaco no GE, GP e GM foram maiores que as no GV. Quanto à hemogasometria, a pressão parcial de oxigênio no sangue arterial (PaO2) foi maior no GV do que no GE e GP. Em relação às variáveis respiratórias, os valores da pressão alveolar de oxigênio (PAO2), diferença alvéolo-arterial de oxigênio (AaDO2), espaço morto fisiológico (Vdfis) e espaço morto alveolar (Vdalv) no GE foram maiores do que no GM e GV . Enquanto, as médias do conteúdo arterial de oxigênio (CaO2), diferença entre a tensão de o dióxido de carbono alveolar e o expirado [P(a-ET)CO2], volume corrente (Vt) e tempo inspiratório (Tinsp), no GE foram menores do que no ao GV e GM... / The effects of spontaneous ventilation, pressure support ventilation (VPS), synchronized intermittent mandatory ventilation (SIMV) and ventilation with pressure support and volume assured (VAPSV) on cardiovascular, blood-gas and respiratory dynamic variables, in rabbits anesthetized with continuous infusion of propofol and underwent acute hypovolemia, were evaluated. Forty New Zealand rabbits were randomly assigned into four groups, namely: GE (spontaneous ventilation), GM (SIMV), GP (VPS) and GV (VAPSV). In premedication were administered ketamine (15 mg/kg) and xylazine (1 mg/kg) intramuscularly. Propofol was used in induction (8 mg/kg) and anesthesia maintenance (0.5 mg/kg/min). After 40 minutes, the rabbits were induced to hypovolemia by withdrawing arterial blood (12 ml/kg). The parameters were measured 40 minutes after anesthetic induction (M0) and, then at 10-minute intervals after hipovolemia induction (from M1 to M6). Numeric data were submitted to the least-squares using the SAS program. In the hemodynamic parameters, means of cardiac output in GP, GE and GM were higher than in GV. About blood-gas parameters, arterial partial pressure of oxygen (PaO2) was bigger in GV than in GE and GP. The arterial hemoglobin saturation (SaO2) was lower in GP than in GV. Regarding respiratory variables, the values of alveolar oxygen partial pressure (PAO2), alveolar-arterial oxygen gradient (AaDO2), physiological dead space (Vdfis), and alveolar dead space (Vdalv) in GE were bigger than in GM, GV and GP. While, means of arterial oxygen content (CaO2), alveolar-arterial carbon dioxide gradient [P(a-ET)CO2], tidal volume (Vt) and inspiratory time (Tinsp), in GE were lower than in GV,GM and GP. The peak inspiratory pressure (PIP) was higher compared to the GV and GM, work of breathing was higher compared to the GV to GV ... (Complete abstract click electronic access below)

Page generated in 0.0528 seconds