• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 22
  • Tagged with
  • 22
  • 22
  • 22
  • 19
  • 17
  • 12
  • 11
  • 9
  • 7
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Efeito do material de recobrimento na deformação sofrida por infra-estruturas de próteses fixas implanto-suportadas, utilizando extensômetros lineares elétricos

Antônio Francisco Grando 31 March 2003 (has links)
O sucesso dos implantes osseointegrados tem a influência decisiva dos aspectos biomecânicos, os quais interagem implantes, tecido ósseo e as próteses. O equilíbrio das forças que atuam sobre este complexo, remete-nos às diversas técnicas e materiais utilizados para a confecção das próteses fixas implanto-suportadas. O desenvolvimento de técnicas e materiais, bem como os desenhos das próteses vem trazendo um novo alento nas pesquisas. Este trabalho teve como objetivo averiguar a influência dos materiais de recobrimento estético, utilizados na confecção de próteses fixas implanto-suportadas, com relação à deformação destas próteses. Esta análise foi feita utilizando-se extensômetros lineares elétricos, analisando dois materiais de recobrimento. Um corpo de prova simulando uma prótese fixa de arco total, fundida em liga de paládioprata e recoberta em uma de suas metades por porcelana e na outra, por resina acrílica termopolimerizável. O corpo de prova foi fixado a um modelo-mestre e, após, aplicada uma carga estática vertical de 35,2 N, na extremidade livre, a uma distância de 10, 15 e 20 mm para distal do centro do implante terminal. Os resultados demonstraram que a aplicação de materiais de recobrimento estético, sobre uma infraestrutura metálica, tornam a mesma mais rígida e conseqüentemente com menor deformação. Outro fator confirmado nesta pesquisa foi a influência direta da extensão da extremidade livre que, nos pontos mais distantes de aplicação da carga, proporcionou maiores deformações. A pesquisa demonstrou que a porcelana proporciona menores índices de deformação da infra-estrutura metálica a ela associada, porém, fatores clínicos como qualidade e quantidade óssea, número e disposição dos implantes é que definem a escolha do material de recobrimento mais apropriado para cada situação. / The success of osseointegrated implants has a decisive influence of biomechanical aspects in wich implants, bone tissue and prosthesis are involved. The balance between the forces acting on this complex refer us to the diversity of methods and materials used to fabricate implant supported prosthesis. The aim of this study was to verify the influence of aesthetic covering materials on the deformation of cantilevered frameworks. Strain gauges were bonded to the inferior surface of a silver-palladium framework covered with ceramic and thermoacrylic resin on each of its two halves. The framework was fixed to a metallic master model and a 35.2N vertical static load was apllied to the free end at the distances of 10, 15 and 20mm distal to the terminal abutment. The results showed that the use of a rigid material such as ceramic stiffen even more the framework, with consequently less deformation. Another finding that was confirmed in this study was the direct influence of cantilever length on deformation of implant supported frameworks.
12

Estudos eletroquímicos in vitro e in vivo da liga níquel–cromo–molibdênio– titânio aplicada em supraestruturas de implantes orais / In vitro and in vivo electrochemical studies of nickel-chromium-molybdenum-titanium alloy applied to oral implant suprastructures

Inada, Eduardo 21 October 2005 (has links)
Este trabalho avaliou o comportamento eletroquímico da liga de níquel-cromo-molibdênio- titânio em relação à liga ouro-platina-paládio em meio de NaCl 0,15 mol.L -1 a 36,5ºC. Os estudos in vitro também envolveram a caracterização eletroquímica do titânio, uma vez que as referidas ligas são empregadas em supraestruturas de implantes osseointegrados. Os estudos in vivo foram feitos com as ligas formando par com titânio comercialmente puro grau IV. Nos estudos in vitro, foram utilizadas técnicas de medidas de potencial de circuito aberto, curvas de polarização anódica e espectrofotometria de absorção atômica de chama. Os estudos in vivo foram interpretados utiliza ndo a microscopia eletrônica de varredura e a espectroscopia por dispersão de energia. A liga de ouro-platina-paládio e o titânio apresentaram resultados reprodutíveis. Suas superfícies são homogêneas e os valores de potencial de circuito aberto estacionário dos dois materiais diferem de menos de 100 mV. A permanência da liga ouro-platina-paládio junto do titânio, por seis meses no ambiente oral, mostrou por microscopia eletrônica de varredura, a estabilidade da liga áurica e do titânio. A liga de níquel-cromo-molibdênio-titânio não apresentou reprodutibilidade nos resultados de potencial de circuito aberto e nas curvas de polarização anódica, apresentando uma faixa de pontencial muito reduzida de passividade, 100 mV. Na análise pela espectrofotometria de absorção atômica de chama, a liga ouro-platina-paládio apresentou pequena divergência com os dados fornecidos pelo fabricante, mostrando conter, além do ouro, platina e paládio, cerca de 1% de prata. A liga níquel-cromo-molibdênio-titânio, na análise pela espectrofotometria de absorção atômica, apresentou grandes divergências com os dados fornecidos pelo fabricante, fora da faixa de composição em que foi patenteada. Foi detectada a presença de alumínio em quantidade significativa, elemento não declarado pelo fabricante. O teor de níquel está acima da especificação, enquanto que o teor de titânio e de cromo se encontram abaixo. A análise por microscopia eletrônica de varredura com igual amplificação empregada para o estudo da liga áurica e do titânio, revelou que a liga níquel-cromo-molibdênio-titânio apresenta superfície heterogênea, caracterizada por quatro fases distintas: (fase 1 – rica em titânio; fase 2 – rica em níquel; fase 3 – rica em níquel e cromo; fase 4 – rica em molibdênio). A permanência da liga de níquel-cromo-molibdênio-titânio junto ao titânio, por seis meses no ambiente oral, mostrou por microscopia eletrônica de varredura, na análise por elétrons secundários, depressões na superfície da amostra na fase 2, sugerindo oxidação da fase rica em níquel, evidenciada pela presença de oxigênio superficial, quando comparada à mesma fase na superfície apenas polida. / The electrochemical behavior of the nickel-chromium-molybdenum-titanium (Ni-Cr-Mo-Ti) alloy was studied and compared to a gold-platinum-palladium (Au-Pt-Pd) alloy in 0.15 mol.L -1 NaCl medium at 36.5ºC. In vitro studies also involved the electrochemical titanium characterization since these alloys are employed in osseointegrated implant suprastructures. In vivo studies were made using alloy-titanium (Ti cp) couples. Open circuit potential (OCP) measurements, anodic polarization curves (APC) and flame atomic absortion spectrophotometry (FAAS) were used as techniques in in vitro experiments. Scanning electronic microscopy (SEM) and energy dispersion spectroscopy (EDS) were used in order to interpret in vivo experiments. The Au-Pt-Pd alloy and Ti showed reproducible results. Their surfaces are homogeneous and the stationary OCP values of the two materials differ by a value less than 100 mV. The permanence of Au-Pt-Pd alloy near titanium for six months in oral environment showed by SEM the stability of the two materials. The Ni-Cr- Mo-Ti alloy did not show reproducibility in OCP and APC results, exhibiting narrow potential range of passivity about 100 mV. The Au-Pt-Pd alloy, under FAAS analysis, presented some divergence in the chemical composition when compared to that one previously provided by the manufacturer. FAAS detected 1% weight of silver. The Ni-Cr-Mo-Ti alloy, however, presented significant divergences and a chemical composition different from that one corresponding to the patent. The presence of aluminum not declared by the manufacturer was detected in meaningful amounts. SEM analysis of Ni-Cr-Mo-Ti alloy with the same amplification used for Au-Pt- Pd alloy and Ti showed a heterogeneous surface characterized by four phases: phase 1 – rich in titanium; phase 2 – rich in nickel; phase 3 – rich in nickel and chromium; phase 4 – rich in molybdenum. The permanence of Ni-Cr-Mo-Ti alloy,for six months in oral environment, showed by SEM using secondary electrons, depressions on the phase 2 area, suggesting oxidation of the rich nickel phase, with a significant oxygen presence, when compared to the correspondent area on the polishing surface.
13

Avaliação da precisão das técnicas de moldagem para próteses implantossuportadas sobre implantes alinhados e implantes não-alinhados

Muñoz Chávez, Alejandro [UNESP] 28 March 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-03-28Bitstream added on 2014-06-13T19:58:14Z : No. of bitstreams: 1 munozchavez_a_me_arafo.pdf: 1098693 bytes, checksum: 17a654ba992a69bd6c38b4699551735e (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Dentre as inúmeras fases clínicas e laboratoriais de um tratamento protético, as técnicas de moldagem para próteses implantossuportadas são ainda responsáveis por grande preocupação e controvérsia entre os pesquisadores. Este estudo in vitro teve como objetivo avaliar a precisão de uma técnica de registro (Index) e de três técnicas de moldagem (transferentes Quadrados, Quadrados unidos e Quadrados com prolongamentos em forma de hélice) associadas a duas situações clinicas (análogos alinhados e não-alinhados). Todos os componentes protéticos utilizados foram da empresa Conexão (Conexão Sistemas de Prótese). Foi construído um modelo mestre de resina epóxica simulando um arco inferior parcialmente desdentado onde foram fixados seis análogos de pilares Micro-Unit. Duas estruturas metálicas de três elementos sendo três alinhados e três não-alinhados e vinte e uma moldeiras individuais de resina acrílica foram confeccionadas. O material de moldagem utilizado foi um poliéter (Impregum Soft Média Viscosidade - 3M ESPE) e o gesso empregado foi um gesso tipo IV (FujiRock -GC Corp), espatulado à vácuo. Foi obtido um total de vinte e um modelos, sendo sete por técnica, mais sete registros do index... / The present in vitro study compared the dimensional accuracy of a master cast (control group) with verification jig (Index) and 3 impression techniques (squared impression copings, squared impression copings splinted with autopolymerizing acrylic resin and squared impression copings with prolongations created from autopolymerizing acrylic resin in the vestibule-lingual direction). Materials and Methods. An epoxy resin cast of a partially dentulous mandibular was fabricated with 6 abutment replicas, two passive implant frameworks and twenty-one identical custom impression trays were made with autopolymerizing acrylic resin... (Complete abstract, click electronic access below)
14

Avaliação da interface osso/implante após o uso do copolímero de PLA/PGA associado a osso autógeno em coelhos: estudo biomecânico e imunohistoquímico

Zanetti, Liliane Scheidegger da Silva [UNESP] 19 August 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-08-19Bitstream added on 2014-06-13T21:02:12Z : No. of bitstreams: 1 zanetti_lss_dr_araca.pdf: 1415676 bytes, checksum: 6158721af6f6a1ee60c101f886650479 (MD5) / Este estudo avaliou o uso do c opolímero de ácido poliláctico e poliglicólico (PLA/PGA) associado ao osso autógeno raspado, no reparo ósseo ocorrido ao redor de implantes inseridos em leitos sobrefresados, em tíbias de coelhos. (2) Material e métodos: Foram incluídos no estudo 20 coelhos e inseridos 40 implantes, divididos em dois grupos: Controle (C) e PLA/PGA adicionado a osso autógeno (G). Após fresagem controlada para simular a perda da estabilidade primária, cada implante foi inserido no leito preparado, tendo sido adicionado a sua superfície o copolímero PLA/PGA associado a osso autógeno raspado obtido manualmente. O grupo controle consistiu do implante com o espaço do leito preenchido por coágulo sangüíneo. Os animais foram sacrificados nos períodos de 15, 40 e 60 dias pós-operatórios, e foram realizadas as análises biomecânica e Imunoistoquímica. As tíbias onde estavam inseridos os implantes foram removidas, desc alcificadas, crioprotegidas e obtidos cortes que foram submetidos à reação imunoistoquímica mediante a utilização de anticorpos primários para RANKL, OPG e OC. No período de 60 dias pós-operatórios a analise biomecânica de torque-reverso foi realizada antes da descalcificação. (3) Resultados: Os resultados obtidos demonstraram que o copolímero PLA/PGA misturado ao osso autógeno apresentou-se biocompatível, bioabsorvivel e permitiu a neoformação óssea em contato com o implante, revelada pela análise da expressão das proteínas que regulam o ganho e a perda de massa óssea. E, houve predominância significante de deposição óssea e estabilidade revelada pela análise de torque-reverso (a= 0,05). (4) Conclusões: O copolímero de PLA/PGA pode ser utilizado no preenchimento de defeitos sobrefresados ao redor... / This study evaluated the polylactic and polyglycolic acid copolymer (PLA/PGA) with sc raped bone harvest in the bone repair occurrence of implants placed in large stream beds, in rabbit tibia. (2) Materials and Methods: Twenty rabbits had been enclosed in the study and 40 implants, in two groups: Control (C), PLA/PGA with the autologous bone scraped (G). After controlled drilled to simulate the loss of the primary stability, each implant was placed in the prepared stream bed, having been added to its surface the PLA/PGA copolymer with autologous bone scraped manually (G). The control group consisted of the implant placed in the space filled by blood. The animals had been sacrificed in the periods 15, 40 and 60 postoperative days, where the analyses had been carried through biomechanics and imunohistochemistry. The tibias where the implants were inserted had been removed, decalcified, frozen and getting cuts that had been submitted the imunoistochemistry reaction by means of the use of primary antibodies for RANK L, OPG and OC. In the 60 days period postoperative the against-torque biomechanics was carried through before the decalcified. (3) Results: The gotten results had disclosed that the copolymer PLA/PGA with bone graft showed biocompatibility, bioabsorption and allowed bone growing in contact with the implant, disclosed by expression of the proteins that regulate the profit and mass bone loss. And, had significant predominance of bone deposition and stability disclosed by against-torque ( = 0,05). (4) Conclusions: The PLA/PGA copolymer can be used filling defects drilled around implants in tibia of rabbits, when added bone harvest sc raped, therefore it presents characteristic s like biocompatibility and biodegradation, being totally resorpted and substituted by bone, allowing the bone formation with quality in the interface bone/implant.
15

Avaliação do processo de reparo periimplantar utilizando matriz óssea heterógena desmineralizada ou osso autógeno: análise histológica e histométrica em tíbias de coelhos

Salim, Martha Alayde Alcantara [UNESP] 27 November 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-11-27Bitstream added on 2014-06-13T21:02:12Z : No. of bitstreams: 1 salim_maa_dr_araca.pdf: 2801897 bytes, checksum: 99b625311eab55330261435209d48950 (MD5) / Este estudo teve como objetivo avaliar o reparo ósseo em defeitos periimplatares experimentais utilizando enxerto autógeno e implante de matriz óssea bovina desmineralizada em tíbias de coelhos. Foram instalados 30 implantes de titânio diâmetro de 3,75 mm plataforma regular (4,1 mm) e altura de 10 mm, no qual cada animal recebeu dois implantes na face lateral da porção mediana da tíbia. Ao redor dos implantes foi confeccionado defeito ósseo de 6,0 mm de diâmetro através da trefina e enxertado no local osso autógeno ou matriz óssea heterógena desmineralizada. As lâminas obtidas foram submetidas à análise histológica e histométrica com contagem das áreas de osso neoformado, matriz óssea bovina, medula e enxerto de osso autógeno. Como resultado observou-se diferença significativa entre a formação de novo osso no período de 15 dias quando comparado o grupo de implante de matriz óssea bovina desmineralizada e enxerto autógeno, demonstrando maior formação óssea neste último; e diferença significativa entre a permanência do tecido implantado em relação ao enxerto autógeno, demonstrado pela permanência da matriz no período de 60 dias. Avaliando os dados obtidos nesta pesquisa concluímos que o processo de reparo periimplantar ocorreu com maior neoformação óssea no grupo tratado por enxerto de osso autógeno e a matriz óssea bovina desmineralizada se comportou como um condutor ósseo de lenta absorção sem demonstrar reação inflamatória aguda ou crônica. / This study aimed to evaluate the bone healing in experimental periimplatar defects using autogenous graft and implantation of bovine demineralized bone matrix in the tibia of rabbits. Were installed 30 titanium implants of 3.75 mm diameter regular platform (4.1 mm) and height of 10 mm, in which each animal received two implants in the median portion of the tibial. Around the implants was made bone defect of 6.0 mm in diameter through the trephine and grafted in place autogenous bone or demineralized bone matrix heterogenous. The slides obtained were subjected to histological and histometric count with areas of newly formed bone, bovine bone matrix, bone marrow and bone graft. Results revealed a significant difference between the formation of new bone within 15 days when compared to the group of implant bovine demineralized bone matrix and autogenous graft, showing a higher bone formation in the latter, and a significant difference between the permanence of the implanted tissue in compared to autograft, demonstrated by the permanence of the matrix within 60 days. Evaluating the data obtained in this study concluded that the repair process was better in periimplant bone formation than in the group treated with autogenous bone graft and demineralized bovine bone matrix acted as a conductor low absorption without showing acute inflammatory reaction or chronic.
16

Osseointegração de implantes de titânio com modificação da superfície por ablação a laser e recobrimento por hidroxiapatita biomimética: estudo biomecânico e histomorfométrico em tíbia de coelhos

Faeda, Rafael Silveira [UNESP] 15 June 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:00Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-06-15Bitstream added on 2014-06-13T21:05:33Z : No. of bitstreams: 1 faeda_rs_dr_arafo.pdf: 15247078 bytes, checksum: c62d1ae9dfd05690aa2ca25b49d04945 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O sucesso dos sistemas modernos de implantes dentais tem sido relacionado ao desenvolvimento do design e das características de superfícies dos implantes. O propósito do presente estudo foi avaliar duas novas superfícies de implantes (modificada por laser - LMS e recoberta por hidroxiapatita biomimética - HA), comparando-as a outro implante comercial, (superfície usinada – MS). Um total de 144 implantes (3,75 x 10mm), 48 de cada superfície, foram instalados na tíbia de coelhos e avaliados após 4, 8 e 12 semanas. Após os períodos de cicatrização os animais foram sacrificados, um dos implantes expostos e a força necessária para derosquea-los foi aferida por um torquímetro analógico. O outro implante foi removido com o tecido ósseo peri-implantar e processado por corte histológico calcificado para análise histomorfométrica do contato osso-implante (BIC%) e da área óssea entre espiras (BBT%). Em 4 e 8 semanas, os implantes HA apresentaram valor de torque de remoção estatisticamente superior (p<0,05) quando comparado aos demais, sendo o mesmo observado para os implantes LMS quando comparados aos MS. Após 12 semanas, os implantes HA e LMS foram estatisticamente superiores aos implantes MS. Por outro lado, a análise do contato osso-implante mostrou que na região cortical, os implantes LMS e HA foram estatisticamente superiores ao MS para todos os períodos de cicatrização, sem diferença estatística entre LMS e HA. A análise histomorfométrica mostrou que, quando comparados na região endosteal, os implantes LMS e HA foram estatisticamente superiores ao MS no período inicial de cicatrização. Embora os implantes LMS e HA não apresentassem diferenças estatísticas entre eles, uma tendência de maiores valores de BIC% para HA na região endosteal foi observada em todos os períodos do estudo.Os resultados deste estudo mostram que apesar de não haver diferença... / Purpose: Considering the great biological potential of the association between laser ablation and hydroxyapatite thin layer coatings to create an interesting bioactive environment on titanium dental implants, the aim of the present study was to investigate, by histomorphometrical and removal torque analysis, the histological effects of a surface treatment created by laser-ablation (Nd:YAG) and, later, thin deposition of HA particles by a chemical process compared to implants with only laser-ablation and implants with machined surfaces. Materials and Methods: Forty-eight rabbits received two implant by tibiae of the following surfaces: Machined surface (MS), laser-modified surface (LMS) and biomimetic hydroxiapatite coated surface (HA). After 4, 8 and 12 weeks of healing, one implant was exposed, and the needed force to unscrew measured using an analogical torque gauge. The other implant and surrounding bone was removed and prepared by a calcified histological process. The percentage of bone-to-implant contact (BIC) and the bone area formed between the threads (BBT) were evaluated separately to the cortical and endosteal region. Results: The difference was statistically significant (P < .05) between the LMSMS and HA-MS surfaces in all periods of evaluation, and between LMS-HA to 4 and 8 weeks of healing. The surface characterization showed a deep, rough, and regular topography provided by the laser conditioning, that was followed by the HA coating. Average BIC percentage in the cortical region was significantly higher (P<0.001) on the LMS and HA implants, compared with MS ones for all periods of healing, having no statistical differences between LMS and HA. When compared in the endosteal area, the LMS and HA implants showed statistically higher (P<0.01) BIC percentage values than MS at the initial periods of healing (LMS after 4 weeks and HA after 4 and 8 weeks, respectively)... (Complete abstract click electronic access below)
17

Avaliação de implantes de titânio com modificação da superfície por abrasão a laser ou recobrimento por hidroxiapatita biomimétrica. Estudo biomecânico em tíbia de coelhos

Faeda, Rafael Silveira [UNESP] 16 March 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-03-16Bitstream added on 2014-06-13T20:08:38Z : No. of bitstreams: 1 faeda_rs_me_arafo.pdf: 1508242 bytes, checksum: 76a3276ed9cd6a6e7947d633681c4217 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Universidade Estadual Paulista (UNESP) / O sucesso dos sistemas modernos de implantes dentais tem sido relacionado ao desenvolvimento do design e das características de superfícies dos implantes. O propósito do presente estudo foi avaliar duas novas superfícies de implantes (modificada por laser - SML e recoberta por hidroxiapatita biomimética - HA), comparando-as a outros dois implantes comerciais, (superfície usinada - SU e modificada por jateamento e ataque ácido - SMC). Um total de 96 implantes (3,75 x 10mm), 24 de cada superfície, foram instalados na tíbia de coelhos e avaliados após 4, 8 e 12 semanas. Após os períodos de cicatrização os animais foram sacrificados, os implantes expostos e a força necessária para derosquea-los foi aferida por um torquímetro analógico. Em 4 e 8 semanas, os implantes HA apresentaram valor de torque de remoção estatisticamente superior (p<0,05) quando comparado aos demais, sendo o mesmo observado para os implantes SML quando comparados aos SU. Após 12 semanas, os implantes HA e SML foram estatisticamente superiores aos implantes SU. Os resultados deste estudo sugerem que os implantes HA foram superiores aos demais nos períodos iniciais, obtendo uma estabilidade satisfatória com 4 semanas de implantação. Os implantes SML foram superiores aos SU em todos os períodos avaliados, porém não apresentando diferenças quando com parados aos SMC. / The success of modern dental implant systems has been associated with the development of implant designs and surface characteristic. The purpose of this study was to evaluate two new implant surfaces (laser-modified - LSM and biomimetic-hydroxyapatite coating - HA) comparing them with two other commercial implants (machined surface -MS and modified by sandblasted and acid etched - MCS). A total of 96 implants (3,75 x 10mm), 24 of each surface, were placed in rabbit tibia being evaluated after 4, 8 and 12 weeks. After the healing periods, the animals were sacrificed, the implants sites were exposed, and the needed force to unscrew the implants was measured using an analogical torque gauge. At 4 and 8 weeks, the HA implants removal torque was statistically greater (p<0,05) in comparison with the others, being the same observed to LSM when compared with MS. After 12 weeks, the HA and LSM implants were statistically greater just when compared with MS. The results of this study suggest that the HA implants were superior to the other at the initial periods, having a satisfactory stability with 4 weeks post-implantation. The LSM implants were superior to MS at all periods evaluated, but having no difference when compared with MCS.
18

Estudos eletroquímicos in vitro e in vivo da liga níquel–cromo–molibdênio– titânio aplicada em supraestruturas de implantes orais / In vitro and in vivo electrochemical studies of nickel-chromium-molybdenum-titanium alloy applied to oral implant suprastructures

Eduardo Inada 21 October 2005 (has links)
Este trabalho avaliou o comportamento eletroquímico da liga de níquel-cromo-molibdênio- titânio em relação à liga ouro-platina-paládio em meio de NaCl 0,15 mol.L -1 a 36,5ºC. Os estudos in vitro também envolveram a caracterização eletroquímica do titânio, uma vez que as referidas ligas são empregadas em supraestruturas de implantes osseointegrados. Os estudos in vivo foram feitos com as ligas formando par com titânio comercialmente puro grau IV. Nos estudos in vitro, foram utilizadas técnicas de medidas de potencial de circuito aberto, curvas de polarização anódica e espectrofotometria de absorção atômica de chama. Os estudos in vivo foram interpretados utiliza ndo a microscopia eletrônica de varredura e a espectroscopia por dispersão de energia. A liga de ouro-platina-paládio e o titânio apresentaram resultados reprodutíveis. Suas superfícies são homogêneas e os valores de potencial de circuito aberto estacionário dos dois materiais diferem de menos de 100 mV. A permanência da liga ouro-platina-paládio junto do titânio, por seis meses no ambiente oral, mostrou por microscopia eletrônica de varredura, a estabilidade da liga áurica e do titânio. A liga de níquel-cromo-molibdênio-titânio não apresentou reprodutibilidade nos resultados de potencial de circuito aberto e nas curvas de polarização anódica, apresentando uma faixa de pontencial muito reduzida de passividade, 100 mV. Na análise pela espectrofotometria de absorção atômica de chama, a liga ouro-platina-paládio apresentou pequena divergência com os dados fornecidos pelo fabricante, mostrando conter, além do ouro, platina e paládio, cerca de 1% de prata. A liga níquel-cromo-molibdênio-titânio, na análise pela espectrofotometria de absorção atômica, apresentou grandes divergências com os dados fornecidos pelo fabricante, fora da faixa de composição em que foi patenteada. Foi detectada a presença de alumínio em quantidade significativa, elemento não declarado pelo fabricante. O teor de níquel está acima da especificação, enquanto que o teor de titânio e de cromo se encontram abaixo. A análise por microscopia eletrônica de varredura com igual amplificação empregada para o estudo da liga áurica e do titânio, revelou que a liga níquel-cromo-molibdênio-titânio apresenta superfície heterogênea, caracterizada por quatro fases distintas: (fase 1 – rica em titânio; fase 2 – rica em níquel; fase 3 – rica em níquel e cromo; fase 4 – rica em molibdênio). A permanência da liga de níquel-cromo-molibdênio-titânio junto ao titânio, por seis meses no ambiente oral, mostrou por microscopia eletrônica de varredura, na análise por elétrons secundários, depressões na superfície da amostra na fase 2, sugerindo oxidação da fase rica em níquel, evidenciada pela presença de oxigênio superficial, quando comparada à mesma fase na superfície apenas polida. / The electrochemical behavior of the nickel-chromium-molybdenum-titanium (Ni-Cr-Mo-Ti) alloy was studied and compared to a gold-platinum-palladium (Au-Pt-Pd) alloy in 0.15 mol.L -1 NaCl medium at 36.5ºC. In vitro studies also involved the electrochemical titanium characterization since these alloys are employed in osseointegrated implant suprastructures. In vivo studies were made using alloy-titanium (Ti cp) couples. Open circuit potential (OCP) measurements, anodic polarization curves (APC) and flame atomic absortion spectrophotometry (FAAS) were used as techniques in in vitro experiments. Scanning electronic microscopy (SEM) and energy dispersion spectroscopy (EDS) were used in order to interpret in vivo experiments. The Au-Pt-Pd alloy and Ti showed reproducible results. Their surfaces are homogeneous and the stationary OCP values of the two materials differ by a value less than 100 mV. The permanence of Au-Pt-Pd alloy near titanium for six months in oral environment showed by SEM the stability of the two materials. The Ni-Cr- Mo-Ti alloy did not show reproducibility in OCP and APC results, exhibiting narrow potential range of passivity about 100 mV. The Au-Pt-Pd alloy, under FAAS analysis, presented some divergence in the chemical composition when compared to that one previously provided by the manufacturer. FAAS detected 1% weight of silver. The Ni-Cr-Mo-Ti alloy, however, presented significant divergences and a chemical composition different from that one corresponding to the patent. The presence of aluminum not declared by the manufacturer was detected in meaningful amounts. SEM analysis of Ni-Cr-Mo-Ti alloy with the same amplification used for Au-Pt- Pd alloy and Ti showed a heterogeneous surface characterized by four phases: phase 1 – rich in titanium; phase 2 – rich in nickel; phase 3 – rich in nickel and chromium; phase 4 – rich in molybdenum. The permanence of Ni-Cr-Mo-Ti alloy,for six months in oral environment, showed by SEM using secondary electrons, depressions on the phase 2 area, suggesting oxidation of the rich nickel phase, with a significant oxygen presence, when compared to the correspondent area on the polishing surface.
19

Relação da distância interimplantar e altura do ponto de contato na formação de papilas gengivais: estudo em cães / Influence of interimplantar distance and height from the point of contact in the formation of gingival papilae: a study in dogs

Cruvinel, Diogo Rodrigues 24 April 2009 (has links)
Os implantes dentais são considerados uma modalidade de tratamento bastante previsível para a reposição de dentes perdidos. Os implantes osseointegráveis principalmente quando colocados em regiões anteriores devem oferecer, além de excelente função, ótima estética, e fonética. Sendo que o critério para o sucesso envolve o estabelecimento do contorno de tecido mole, apresentando a área interproximal intacta. O propósito deste estudo foi avaliar a influência das diferentes distâncias (3 e 5 mm) entre a crista óssea e ponto de contato interdental, na formação de papila gengival associado à presença de diferentes distâncias (2 e 3 mm) entre implantes contíguos e na região de extremo livre mesial e distal. Foram selecionados para o experimento 8 cães adultos jovens e executada a exodontia dos 4 pré-molares mandibulares: p1, p2, p3, p4, para cada hemi-mandibula. Três meses após as exodontias foram colocados 3 implantes Replace Select Tapered com superfície tratada e dimensões de 4,3 X 10 mm, em cada hemimandibula animal. O primeiro implante foi colocado a 10 mm da distal do canino remanescente, o segundo (intermediário) foi colocado a 2 mm do primeiro e o terceiro implante (posterior) foi colocado a 3 mm do segundo. Foi iniciada a reabilitação protética, no dia da colocação dos implantes. Primeiramente foi feita a moldagem para a confecção das próteses metálicas. As coroas metálicas definitivas, confeccionadas, apresentaram distância do ponto de contato à crista óssea de 3 e 5 mm lado esquerdo e direito respectivamente. Ao completar 12 semanas pós-colocação das próteses definitivas, os animais foram sedados e as análises clínicas foram executadas. Esta avaliação foi feita a partir da utilização de um compasso de pontas secas, medindo as distâncias entre os pontos de contato e as pontas das papilas (PC - P) e dos pontos de contato aos extremos livres mesial e distal (PC - ELM e PC ELD respectivamente). O delineamento das situações experimentais foi executado levando em consideração as associações das diferentes distâncias interimplantar com as diferentes distâncias do ponto de contanto a crista óssea, assim encontramos a seguinte disposição: Situação 01 (PC3A) Distância do ponto de contato a gengiva do extremo livre mesial, do lado esquerdo; Situação 02 (PC3B) Distância do ponto de contato, a gengiva interproximal sendo à distância interimplantar de 2 mm, lado esquerdo da mandíbula; Situação 03 (PC3C) Distância do ponto de contato, a gengiva interproximal sendo a distância interimplantar de 3 mm, lado esquerdo da mandíbula; Situação 04 (PC3D) Distância do ponto de contato a gengiva do extremo livre distal, do lado esquerdo Situação 05 (PC5A) Distância do ponto de contato a gengiva do extremo livre mesial, do lado direito; Situação 06 (PC5C) Distância do ponto de, a gengiva interproximal sendo a distância interimplantar de 3 mm, lado direito da mandíbula; Situação 07 (PC5B) Distância do ponto de contato, a gengiva interproximal sendo a distância interimplantar de 2 mm, lado direito da mandíbula e Situação 08 (PC5D) Distância do ponto de contato a gengiva do extremo livre distal, do lado direito. Ao analisar as medias das alturas gengivais temos: PC3A a média de 2,9±0,5 mm; PC3D 2,5±0,5 mm; PC3B 1,8±0,6 mm; PC3C 2,0±0,8 mm; PC5A 3,0±0,5 mm; PC5D 3,5±0,4 mm; PC5C 3,6±0,4 mm e PC5B 3,9±0,7 mm. Como as premissas de aderência à distribuição normal, independência entre os indivíduos estudados e pareamento entre as diferentes etapas foram cumpridas, empregou-se a análise de variância (ANOVA) para mensurações repetidas, a dois fatores. Nos casos em que a ANOVA encontrou diferença entre as situações testadas, uma comparação a posteriori foi executada por meio do teste de Bonferroni. O nível de significância empregado para todos os testes foi de 0,05 (5%). Logo as distâncias de 2,0 e 3,0 mm entre implantes contíguos não apresentaram diferença significativa na formação de papila quando as restaurações protéticas são confeccionadas com 3 ou 5 mm de distância entre o ponto de contato e a crista óssea. Considerando a provável reabsorção óssea em ambos os grupos, quando a distância do ponto de contato à crista óssea foi inicialmente de 3 mm esta condição apresentou melhores resultados na formação de papilas do que a distância de 5 mm em todas as situações estudadas. A presença do ponto de contato de 3 mm influência positivamente na formação de papila, quando comparada com as regiões de extremo livre. / The dental implants are considered a form of treatment rather predictable for replacement of lost teeth Implants should offer, as well as excellent function, aesthetics and phonetics great, especially when placed in anterior regions, where the criterion for success involves the establishment contour of the soft tissue, showing the area intact interproximal The purpose of this study was to evaluate the influence of different distances between the bone crest and interdentally contact point, with 3 and 5 mm, the formation of gingival papilla associated with the presence of different distances of 2 and 3 mm between implants and the adjacent region of mesial and distal end free. Were selected for the experiment 08 dogs and young adults performed the extraction of the 4 pre molars mandibles: p1, p2, p3, p4, for each hemi-mandible. Three months after the tooth extractions were placed 3 Replace Select Tapered implants with treated surface and dimensions of 4.3 X 10 mm in each animal hemi mandibles. The first implant was placed at 10 mm distal of the canine left, the second (middle) was placed at 2 mm from the first and third implant (back) was placed at 3 mm from the second. Prosthetics rehabilitation has begun on the day of the placement of implants. First was the casting for the manufacture of metal stents, since the provisional prostheses were made of acrylic resin so that the distance between the point of contact and the bone crest is 3 mm on the left side of the mandible and 5 mm on the right. The final metal crowns, made, made from the point of contact to bone crest of 3 and 5 mm. After completing 12 weeks after placement of final prosthesis, the animals were sedated and the clinical tests were performed. This evaluation was made from the use of a dry bar for tips, measuring the distances between the points of contact and the tips of the papillae (PC - P) and the contact points of the mesial and distal ends free (PC - PC and ELM - ELD respectively). The design of the experimental situations was implemented taking into account the associations of different distances interimplantar with different distances from the long bone crest, we found the following provision: Location - 01 (PC3A) Distance from the point of contact to end the free gingiva mesial to the left; Situation - 02 (PC3B) Distance from the point of contact, the gingival interproximal distance being interimplantar of 2 mm, the left side of the mandible; Situation - 03 (PC3C) Distance from the point of contact, the gingival interproximal and interimplantar a distance of 3 mm, the left side of the mandible; Situation - 04 (PC3D) Distance from the point of contact to the extreme free gingival distal to the left position - 05 (PC5A) Distance from the point of contact to the extreme free gingival mesial on the right side; Situation - 06 (PC5C) distance from the interproximal gingival interimplantar the distance of 3 mm, right side of the jaw; Situation - 07 (PC5B) Distance from the point of contact, the gingival interproximal the distance interimplantar of 2 mm, the right side of the mandible and Situation - 08 (PC5D) Distance from the point of contact to free distal end of the gingival on the right side. In examining the measures of gingival heights are: PC3A an average of 2.9 ± 0.5 mm; PC3D 2.5 ± 0.5 mm; PC3B 1.8 ± 0.6 mm; PC3C 2.0 ± 0.8 mm; PC5A 3.0 ± 0.5 mm; PC5D 3.5 ± 0.4 mm; PC5C 3.6 ± 0.4 mm and PC5B 3.9 ± 0.7 mm. As adherence to the assumptions of normal distribution, independence among the subjects studied and matching between the different stages have been completed, using the analysis of variance (ANOVA) for repeated measurements, the two factors. Where ANOVA found the difference between the conditions tested, a posteriori comparison was performed using the Bonferroni test. The significance level used for all tests was 0.05 (5%). Once the distances of 2.0 and 3.0 mm between adjacent implants showed no significant difference in the formation of the papilla when prosthetic restorations are made with 3 or 5 mm distance between the point of contact and the bone crest. Considering the probable bone resorption in both groups, where the distance from the point of contact to the bone crest was originally the condition of 3 mm showed better results in the formation of papillae than the distance of 5 mm in all cases studied. The presence of the point of contact 3-mm positively influence the formation of papilla, when compared with regions of extreme freedom.
20

Análise da influência dos sistemas de retenção para overdentures implanto-retidas na distribuição interna das tensões, através do método de elementos finitos

Tabata, Lucas Fernando [UNESP] 05 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-05Bitstream added on 2014-06-13T20:37:56Z : No. of bitstreams: 1 tabata_lf_me_araca.pdf: 8309973 bytes, checksum: 5d726f976a2382ac0dc6e3d5eff78d89 (MD5) / Universidade Estadual Paulista (UNESP) / No tratamento com overdentures o mecanismo de transmissão e distribuição das tensões geradas por cargas funcionais através dos sistemas de retenção e implantes ao osso não está bem documentado. A intensidade e a forma como esta tensão é transmitida e distribuída ao osso determina os locais e a amplitude da reabsorção óssea. O objetivo deste estudo foi analisar, através do Método de Elementos Finitos (MEF) bidimensional, as tensões geradas pelas overdentures e transmitidas aos sistemas de retenção, implantes e tecido ósseo adjacente. Foram construídos em computador, através do programa AutoCAD, três modelos matemáticos representativos de cortes frontais da mandíbula na região inter-caninos, sendo: modelo A (Controle), mandíbula edêntula suporte de prótese total convencional; modelo B, mandíbula edêntula, suporte de overdenture com dois implantes ferulizados por meio de barra e clipe plástico; modelo C, mandíbula edêntula, suporte de overdenture com dois attachments esféricos O'rings em dois implantes isolados. Para análise, foi aplicada carga vertical de 100N em três regiões distintas: nos incisivos centrais inferiores, no canino inferior esquerdo e no primeiro molar inferior esquerdo. Os mapas de tensão evidenciaram as máximas e mínimas tensões e foram agrupados de acordo com as situações clínicas simuladas, para análise dos efeitos dos sistemas de retenção sobre as estruturas de suporte. O modelo A apresentou menores valores de tensão máxima (10,928MPa) que os modelos B (74,244MPa) e C (78,454MPa) em relação aos tecidos de suporte, sendo que os maiores valores foram obtidos no modelo C, na região peri-implantar do osso cortical para os três carregamentos aplicados. Os resultados sugerem a ferulização dos implantes e a utilização do sistema de retenção barra-clipe quando se pretende ter distribuição otimizada de tensões no tratamento com overdentures implanto-retidas. / on treatment with overdenture, the transfer and distribution mechanism of the stress generated by functional loads through retention system and implants to bone it is not well documented, The intensity and the manner how this stress is tranfered and distributed to bone determine the sites and amplitude of bone resorption. The objective of this study was to analyse, through Finite Element Analysis (FEA) bidimensional, the stress generated on overdentures and transfer to retention system, implants and surrounding bone tissue. Three mathematic models were made in computer, through AutoCAD software, representing a frontal mandibular slice of inter-canine... (Complete abstract click electronic access below)

Page generated in 0.1292 seconds