• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 22
  • Tagged with
  • 22
  • 22
  • 22
  • 19
  • 17
  • 12
  • 11
  • 9
  • 7
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Etiologia, progressão e tratamento das peri-implantites

Shibli, Jamil Awad [UNESP] 24 March 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:28Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-03-24Bitstream added on 2014-06-13T20:08:48Z : No. of bitstreams: 1 shibli_ja_dr_arafo.pdf: 1695083 bytes, checksum: 3338c6c93a1d7714402de61c6827df6c (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
2

Avaliação clínica e da freqüência de ressonância, de implantes instalados por meio de técnica cirúrgica modificada na maxila e submetidos à função imediata

Vasconcelos, Laércio Wonhrath [UNESP] 03 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-03Bitstream added on 2014-06-13T19:43:11Z : No. of bitstreams: 1 vasconcelos_lw_dr_araca.pdf: 3387652 bytes, checksum: 665ddeee618bbda24e7caff661ab090e (MD5) / Universidade Estadual Paulista (UNESP) / Brånemark et al. (1969) introduziram os implantes osseointegrados como forma de ancoragem para próteses com intuito de substituir os dentes perdidos, tanto na mandíbula como na maxila. Desde então, foram instituídas modificações no protocolo clássico. Entre elas, a submissão dos implantes à função imediatamente após a sua instalação. Esse procedimento tem sido largamente estudado na mandíbula, com altos índices de sucesso, contudo, a literatura é escassa quanto à aplicação desta técnica na maxila. Propôs-se, então, avaliar a função imediata em implantes instalados em maxilas desdentadas totais, no momento da cirurgia e após seis e 12 meses de função. Para tanto foi utilizada uma técnica cirúrgica modificada e a avaliação da estabilidade dos implantes foi feita por meio da análise da freqüência de ressonância. Foram selecionados 10 pacientes, nos quais foram instalados seis implantes na maxila com a submissão dos mesmos à função imediata mediante a instalação de uma prótese fixa, com infra-estrutura metálica, 24 horas após a cirurgia. Estes pacientes foram acompanhados por um período de 12 meses. As medidas da estabilidade do implante foram realizadas no momento da instalação dos implantes (M0) e após seis (M6) e 12 meses (M12). Após o período de acompanhamento, foram obtidos índices de sucesso de 95% para os implantes e 90% para as próteses. Quanto aos valores da estabilidade dos implantes, foi observada uma diferença estatisticamente significativa entre os valores de M0 e M6, e, M0 e M12. Sendo o M0, o momento com maior valor do coeficiente de estabilidade. Não houve diferença estatisticamente significativa entre os valores da estabilidade obtidos no M6 e M12. Quando comparados, o valor da estabilidade para cada implante, não apresentaram diferença estatisticamente significativa no mesmo período de avaliação... / Brånemark et al. (1969) presented the osseointegrated implants as a way to anchorage prosthesis for missing teeth substitution in the jaws. Ever since, modifications in the classical protocol were instituted. Among them, the functional loading of the implants, immediately after their installation. This procedure have been well documented in mandibles, with high success levels, however, literature is scarce about the application of this technique in maxilla. The purpose of this study is to evaluate the immediate function in implants installed in totally edentulous maxillas, at the surgical moment and after six and 12 months of function. For so much, a modified surgical technique was used and implant stability was evaluated through the resonance frequency analysis. Ten patients were selected, who received six implants installed in the maxilla and submitted to immediate function. A metallic infra-structure fixed prosthesis was installed 24 hours after the surgery. The follow-up period was of 12 months. Implant stability measurements were taken at the surgical moment (M0) and after six (M6) and 12 months (M12). After the follow-up period, success rates of 95% for implants and 90% for prosthesis were achieved. As for the implant stability values, significant statistical difference were observed between M0 and M6, and M0 e M12, and no significant statistical difference was observed between M6 and M12. When the stability values of each implant was compared, no significant statistical difference was observed between them for different evaluation periods. It is concluded that the submission of implants, installed in the maxilla through a modified technique, to immediate function is a well predictable procedure, ever since well selected and executed. The resonance frequency analysis is an efficient method for the evaluation of the initial and late implants’ stability.
3

Efeito do material de recobrimento na deformação sofrida por infra-estruturas de próteses fixas implanto-suportadas, utilizando extensômetros lineares elétricos

Grando, Antônio Francisco 31 March 2003 (has links)
O sucesso dos implantes osseointegrados tem a influência decisiva dos aspectos biomecânicos, os quais interagem implantes, tecido ósseo e as próteses. O equilíbrio das forças que atuam sobre este complexo, remete-nos às diversas técnicas e materiais utilizados para a confecção das próteses fixas implanto-suportadas. O desenvolvimento de técnicas e materiais, bem como os desenhos das próteses vem trazendo um novo alento nas pesquisas. Este trabalho teve como objetivo averiguar a influência dos materiais de recobrimento estético, utilizados na confecção de próteses fixas implanto-suportadas, com relação à deformação destas próteses. Esta análise foi feita utilizando-se extensômetros lineares elétricos, analisando dois materiais de recobrimento. Um corpo de prova simulando uma prótese fixa de arco total, fundida em liga de paládioprata e recoberta em uma de suas metades por porcelana e na outra, por resina acrílica termopolimerizável. O corpo de prova foi fixado a um modelo-mestre e, após, aplicada uma carga estática vertical de 35,2 N, na extremidade livre, a uma distância de 10, 15 e 20 mm para distal do centro do implante terminal. Os resultados demonstraram que a aplicação de materiais de recobrimento estético, sobre uma infraestrutura metálica, tornam a mesma mais rígida e conseqüentemente com menor deformação. Outro fator confirmado nesta pesquisa foi a influência direta da extensão da extremidade livre que, nos pontos mais distantes de aplicação da carga, proporcionou maiores deformações. A pesquisa demonstrou que a porcelana proporciona menores índices de deformação da infra-estrutura metálica a ela associada, porém, fatores clínicos como qualidade e quantidade óssea, número e disposição dos implantes é que definem a escolha do material de recobrimento mais apropriado para cada situação. / The success of osseointegrated implants has a decisive influence of biomechanical aspects in wich implants, bone tissue and prosthesis are involved. The balance between the forces acting on this complex refer us to the diversity of methods and materials used to fabricate implant supported prosthesis. The aim of this study was to verify the influence of aesthetic covering materials on the deformation of cantilevered frameworks. Strain gauges were bonded to the inferior surface of a silver-palladium framework covered with ceramic and thermoacrylic resin on each of its two halves. The framework was fixed to a metallic master model and a 35.2N vertical static load was apllied to the free end at the distances of 10, 15 and 20mm distal to the terminal abutment. The results showed that the use of a rigid material such as ceramic stiffen even more the framework, with consequently less deformation. Another finding that was confirmed in this study was the direct influence of cantilever length on deformation of implant supported frameworks.
4

Avaliação da citotoxicidade dos extratos da corrosão de mini-implantes ortodônticos de TI- 6AL-4V após imersão em saliva artificial fluoretada por 30, 90 ou 180 dias

Lemes, Sandra Stival dos Santos 25 February 2008 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2015-02-12T19:32:51Z No. of bitstreams: 2 Dissertação - Sandra Stival dos Santos Lemes - 2008.pdf: 7357278 bytes, checksum: 783dfa4660c8b2298763eff63fd6a65b (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Erika Demachki (erikademachki@gmail.com) on 2015-02-12T19:33:13Z (GMT) No. of bitstreams: 2 Dissertação - Sandra Stival dos Santos Lemes - 2008.pdf: 7357278 bytes, checksum: 783dfa4660c8b2298763eff63fd6a65b (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-02-12T19:33:13Z (GMT). No. of bitstreams: 2 Dissertação - Sandra Stival dos Santos Lemes - 2008.pdf: 7357278 bytes, checksum: 783dfa4660c8b2298763eff63fd6a65b (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2008-02-25 / The alloys used in the orthodontic therapy are subject to the corrosion process in the oral environment. Orthodontic mini-implants Ti-6Al-4V are an excellent source for intraoral anchorage; however, their corrosion resistance in the presence of fluoride is currently unknown. The purpose of this in vitro study was to evaluate the cytotoxic effects of the corrosion extracts of mini-implants Ti-6Al-4V from three different manufacturers when exposed to 200 g/L of sodium fluoride containing artificial saliva for 30, 90 or 180 days. The cytotoxic effects of their corrosion products on L929 cell culture was evaluated by MTT (3- [4,5-dimethylthiazol-2-yl]2,5-diphenyltetrazolium bromide) assay, for cell metabolism and proliferation. The extracts were not cytotoxic and the cytotoxicity assay demonstrated a similar behavior for the samples immersed in artificial saliva in the three evaluated periods. The qualitative analysis, through SEM did not show characteristics of corrosion. The results indicated that the mini-implants tested presented a high corrosion resistance and biocompatibility. / As ligas metálicas utilizadas na terapia ortodôntica estão sujeitas ao processo de corrosão na cavidade bucal. Mini-implantes de Ti-6Al-4V utilizados em ortodontia tornou-se um ótimo recurso de ancoragem intrabucal, contudo, sua resistência à corrosão na presença de flúor é pouco conhecida. O objetivo deste trabalho in vitro foi avaliar a citotoxicidade dos extratos da corrosão de mini-implantes ortodônticos de Ti-6Al-4V de três diferentes marcas comerciais, quando expostos em saliva artificial fluoretada contendo 200 µg/L de fluoreto de sódio, por 30, 90 ou 180 dias. A citotoxicidade dos extratos foi avaliada, em cultura de células L929, por meio da análise do ensaio do MTT (3-{4,5-dimetiltiazol-2il} -2,5-difenil brometo de tetrazólio). Os extratos não foram citotóxicos e o ensaio de citotoxicidade revelou não haver diferenças entre as amostras, demonstrando um comportamento semelhante para os extratos provenientes dos mini-implantes imersos em saliva nos três períodos avaliados. A análise qualitativa, por meio do MEV não revelou áreas com características de corrosão propriamente dita. Os resultados demonstraram que os mini-implantes testados apresentam alta resistência à corrosão e sugerem que são biocompatíveis.
5

Precisão das técnicas de moldagem e vazamento para próteses implantossuportadas

Del'Acqua, Marcelo Antonialli [UNESP] 03 May 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-05-03Bitstream added on 2014-06-13T19:37:32Z : No. of bitstreams: 1 delacqua_ma_me_arafo.pdf: 2803470 bytes, checksum: c3da6f0cf6b27aff80e479e792d68cd7 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Dentre as inúmeras fases clínicas e laboratoriais de um tratamento protético, as técnicas de moldagem e vazamento para próteses implantossuportadas são ainda responsáveis por grande preocupação e controvérsia entre os pesquisadores. Este estudo in vitro teve como objetivo avaliar a precisão de uma técnica de registro (Index) e de três técnicas de moldagem (transferentes Cônicos, Quadrados e Quadrados unidos) associadas a três técnicas de vazamento (Convencional, com tubos de Látex e com análogos unidos com Duralay) para próteses implantossuportadas. Todos os componentes protéticos utilizados foram da empresa Conexão (Conexão Sistemas de Prótese). Foi construído um modelo mestre de latão simulando um arco inferior desdentado onde foram fixados provisoriamente quatro análogos de pilares Micro-Unit perpendicularmente à superfície e paralelos entre si, sendo denominados análogos A, B, C e D. Uma estrutura metálica foi confeccionada e parafusada a quatro novos análogos. Este conjunto foi cimentado passivamente no modelo mestre com resina epóxica. Foram confeccionadas (com 2 mm de alívio) uma moldeira individual de alumínio para a técnica com os transferentes quadrados unidos e outra para as técnicas com os transferentes cônicos e quadrados. O material de moldagem utilizado foi um poliéter (Impregum Soft Média Viscosidade - 3M ESPE) e o gesso empregado foi um gesso tipo IV (Vel-Mix, Kerr), espatulado à vácuo. Foi obtido um total de cinquenta modelos, sendo cinco por técnica. A estrutura metálica foi parafusada com um torque de 10 Ncm em todos os modelos no análogo A, enquanto as medições das fendas formadas foram feitas nos análogos C e D. Este processo foi repetido no análogo D, anotando-se as medidas dos análogos A e B. Estas medições foram feitas por um programa (Leica QWin) que recebia as imagens de uma câmara de vídeo... / Among the countless clinical and laboratories procedures of a prosthetic treatment, the implant impression and pouring techniques for implant-supported restorations are still responsible for great concern and controversy among the researches. This study in vitro investigated the accuracy of a stone Index and of three impression techniques (tapered impression copings, squared impression copings and squared impression copings splinted with Duralay resin) associated to three pouring techniques (Conventional, with tubes of Latex and joining the analogs with Duralay resin) for an osseointegrated implant-supported prostheses. Conexão (Conexão Systems of Prosthesis) prosthetic components were used. A mandibular brass cast was constructed with four stainless steel implant abutments analogs 90° to the surface and parallel among themselves, being denominated analog A, B, C and D. A master framework was made and screwed to four new analogs, which were cemented passively into the model master with epoxy resin. This formed a metal implant cast with a passive implant framework fitted to it. An aluminum custom tray was fabricated for the technique copings splinted with Duralay and other for the techniques tapered and squared copings. Polyether impression material (Impregum Soft medium consistency - 3M ESPE) was used for all impressions. A total of fifty stone casts were formed by carefully vibrating improved dental stone (Vel-Mix, Kerr), mixed under vacuum, being five for technique. The standard framework was seated on each cast and guide pin was tightened in the analog A to 10 Ncm using a torque driver, while the measurements of abutment / framework interface gaps were made in analogs C and D. This process was repeated in analog D, being written down the measures of the analogs ones A and B. These measurements were analyzed using software (Leica QWin) that received the images of a video ...(Complete abstract, click electronic access below)
6

Efetividade de parafusos com tratamento de superfície na estabilidade de pilares em zircônia após carga cíclica

Basílio, Mariana de Almeida [UNESP] 18 March 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-03-18Bitstream added on 2014-06-13T19:16:53Z : No. of bitstreams: 1 basilio_ma_me_arafo.pdf: 801760 bytes, checksum: 7941402e0f93534f3eda18455ce01460 (MD5) / Com o objetivo de prevenir o afrouxamento, parafusos do pilar com lubrificantes sólidos de superfície foram desenvolvidos e introduzidos no mercado. Assim, foi proposto avaliar a efetividade de parafusos de liga de titânio com e sem tratamento de superfície sobre a estabilidade de pilares em zircônia (ZrO2) após carga cíclica, bem como observar alterações estruturais por meio de microscopia eletrônica de varredura (MEV). Para isso, 20 pilares UCLA em ZrO2 foram fixados sobre implantes do tipo hexágono externo com torque de 20 Ncm e divididos em 2 grupos (n=10), conforme o parafuso do pilar: (A) pilar-implante e parafuso de liga de titânio (Ti); (B) pilar-implante e parafuso de liga de titânio com cobertura Diamond Like Carbon (DLC/Ti). O valor do torque reverso (pré-carga) foi mensurado antes e após o carregamento. O teste foi realizado de acordo com a norma ISO 14801. Cargas cíclicas (0,5 x 106; 15 Hz) entre 11 - 211 N foram aplicadas com 30º de inclinação em relação ao longo eixo dos implantes. As médias dos grupos foram calculadas e comparadas utilizando análise de variância de dois fatores e testes F (α=0,05). Os resultados mostraram que antes do carregamento a média do grupo Ti foi significativamente maior que a do grupo DLC/Ti (p=0,021). Após o carregamento ambas as médias 14 diminuíram significativamente, sem diferença significante entre elas (p=0,499). As imagens obtidas na MEV revelaram micro-fraturas na base de assentamento do pilar. Nas condições estudadas, concluiu-se que: (1) os parafusos estudados apresentaram efetividade similar com relação à manutenção da pré-carga; (2) a redução significativa no torque reverso e os danos observados na MEV indicam que o acompanhamento dos pacientes é necessário para assegurar a longevidade das restaurações de ZrO2 implanto-suportadas. / In an attempt to prevent screw-loosening problem, abutment screws with surface treatment were developed. Thus, the aim of the current study was to evaluate comparatively the effectiveness of titanium alloy coated screws and noncoated screws on the stability of ZrO2-ceramic abutments after cyclic loading, as soon as observe possible microdamaging in the structure of the components using a scanning electron microscope (SEM). For this, 20 prefabricated ZrO2-ceramic UCLA abutments were tightened to 20 Ncm on their respective external hex implants and divided equally into 2 groups (n=10), according to the type of screws used: (A) implant-abutment and noncoated titanium alloy screw (Ti); (B) implant–abutment and titanium alloy screw with Diamond Like Carbon surface coating (DLC/Ti). The reverse torque value (preload) of the abutment screw was measured before and after loading. The tests were performed according to ISO norm 14801. A cyclic loading (0,5 x 106; 15 Hz) between 11 - 211 N was applied at an angle of 30 degrees to the long axis of the implants. Group means were calculated and compared using ANOVA and F tests (α=0,05). The results showed that before cyclic loading, the mean of Ti group was significantly higher than the DLC/Ti group (p=0,021). After cyclic loading, both means decreased significantly, with no significant differences 16 between them (p=0,499). Under the studied conditions, it can be concluded that: (1) the two abutment screw types presented similar effectiveness in maintaining preload; (2) the significant decrease in reverse torque values and the microdamaging detected at SEM analysis indicate that patient follow-up is needed to ensure the integrity of the ZrO2-ceramic single-implant restorations.
7

Implantes osseointegráveis instalados sobre raízes reimplantadas tardiamente

Cardoso, Leandro de Carvalho [UNESP] 05 December 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-12-05Bitstream added on 2014-06-13T21:02:13Z : No. of bitstreams: 1 cardoso_lc_dr_araca.pdf: 1917765 bytes, checksum: a068b0645b4f20057a8f729027757d38 (MD5) / O objetivo deste trabalho foi analisar o reparo ósseo peri-implantar de implantes instalados sobre raízes dentárias reimplantadas tardiamente, apresentando processo de anquilose e reabsorção por substituição. Foram utilizados os terceiros e quartos pré-molares inferiores de 4 cães machos (Beagle). Os dentes foram seccionados, e as raízes mesiais extraídas e mantidas durante 1 hora em temperatura ambiente. Após a remoção do ligamento periodontal necrótico e tratamento endodôntico, imergiram-se em fluoreto de sódio por 5 minutos e reimplantou a porção no alvéolo esplintando nas porções distais. Nestas foram realizadas pulpotomia e restauração. Decorridos 30 dias, as porções mesiais tiveram suas coroas seccionadas. Após 5 meses, cinco implantes foram instalados em osso reparado, grupo I, (Controle); nove foram instalados nos alvéolos frescos pós-exodônticos das porções distais (Grupo II – Imediato) e doze implantes foram instalados sobre as raízes mesiais em processo de reabsorção radicular externa (Grupo III – experimental). Decorridos 120 dias, os resultados foram analisados pelo contato osso implante da superfície do implante sem roscas e das três primeiras roscas. Foi avaliada, também, a área de tecido ósseo presente nos espaços internos das três primeiras roscas e da área espelho correspondente. O contato osso implante foi de 55% no grupo controle, 48% no imediato e 40% no grupo experimental. A área de tecido ósseo foi, respectivamente, 71%, 61% e 55%, e a área espelho de tecido ósseo foi de 62%, 60% e 58%. Conclui-se que o reparo ósseo perimplantar de implantes instalados sobre raízes apresentou um pequeno em relação aos outros dois grupos. / The purpose of this study was to analyze the peri-implant bone repair of dental implants placed on delayed reimplated roots, with process of ankylosis and reabsorption by substitution. The lower third and fourth pre-molar of four male dogs (Beagle) was used. The teeth were cut, and the mesial roots were extracted and kept out for 1 hour at ambient temperature. After removal of necrotic periodontal ligament and endodontic treatment, the root was immersed in sodium fluoride for 5 minutes. Then it was reimplanted in the correspondent alveolar bone and splinted in distal portion. A pulpotomy and a crown restoration were conducted on the distal portion. After 30 days, the mesial portions had their crowns cut (decoronation).Moreover, 5 months later, five implants were installed in bone repair, Group I (Control), and nine were installed in the fresh socket of the distal portions, which were extracted (Group II - Immediate). Finally, twelve implants were installed on the mesial roots, with process of external resorption (Group III - experimental). After 120 days, the results were analyzed by bone implant contact, from the surface of the implant without threads to the first three threads. It was also evaluated the area of the bone tissue located in the internal spaces of the first three threads and the corresponding mirror area. The bone implant contact was 55% in the control group, 48% in the immediate group and 40% in the experimental group. The area of bone tissue in the internal threads area was respectively 71%, 61% and 55%, and the mirror area of bone tissue had the following results: 62%, 60% and 58%. It was concluded that peri-implant bone repair of the implant put on the roots with an external resorption showed delay compared to the other two groups.
8

Estudo da influência de corticóides no processo inicial de osseointegração de implantes de titânio instalados em maxilas de ratos

Oliveira, Sérgio Ricardo de [UNESP] 12 February 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:27Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-02-12Bitstream added on 2014-06-13T21:06:12Z : No. of bitstreams: 1 oliveira_sr_dr_araca.pdf: 4808815 bytes, checksum: 6fc8deeffcd2c27c59c5d08cd94ab969 (MD5) / As modalidades terapêuticas que envolvem implantes dentais têm se expandido gradativamente, sendo implantados em uma variedade de estruturas ósseas. Dessa forma, o propósito do presente trabalho foi estudar a influência de corticóides no processo inicial de osseointegração de implantes de titânio instalados em maxilas de ratos. Foram utilizados implantes de titânio c.p., grau II, cônico de 1,4mm de diâmetro e 2,7mm de comprimento, com superfície tratada. Trinta e oito ratos wistar tiveram seus primeiros molares superiores esquerdo e direito extraídos. Após 30 dias de reparo alveolar, dois animais foram sacrificados para confirmar o fim desse processo. Os demais animais tiveram os implantes instalados bilateralmente e foram divididos randomicamente em três grupos: Controle (Ctr/n=12) que não receberam nenhum tipo de tratamento; Placebo (Pl/n=12) e Tratado (Tra/n=12), que receberam injeções diárias de 1 ml de solução salina e corticosterona na dosagem de 5mg/kg, respectivamente. Trinta dias após a implantação, todos os animais foram eutanasiados e tiveram a concentração plasmática do corticóide mensurada: Ctr (101,31 ± 26,7 ng/ml), Pla (95,22 ± 25,36 ng/ml) e Tra (281,37 ± 64,72 ng/ml); e o contato osso-implante determinado: Ctr (96,67%), Pla (82,22%) e Tra (15,73%), nos quais o grupo Tra apresentou-se estatisticamente diferente dos demais grupos (p<0,05). Assim, diante da metodologia empregada, foram evidenciadas menor formação óssea e conseqüente redução da área de tecido ósseo neo-formado na interface osso-implante. / The therapeutic modalities which involves dental implants has been gradually expanded, being implanted in a variety of bone structures. In this way, the aim of the present work was to study the corticoid influence at the initial process of bone integration of titanium implants installed in rat jaws. It were used titanium implants c.p.; grade II, conic with 1,4mm diameter and 2,7mm length, with treated surface. Thirty eight wistar rats had their first upper left and right molars extracted. After 30 days of alveolar repair, two animals were sacrificed to confirm the end of this process. The others had their implants installed bilaterally and they were splited randomly in three groups: Control (Ctr/n=12) which did not receive any kind of treatment; Placebo (Pla/n=12) and Treated (Tre/n=12) which received 1ml daily shots of salt solution and corticosterone at a dosage of 5mg/Kg, respectively. Thirty days after the implantation, all the animals were euthanasiated and the plasmatic concentration of corticoid was measured: Ctr (101,31 ± 26,7 ng/ml), Pla (95,22 ± 25,36 ng/ml) and Tre (281,37 ± 64,72 ng/ml); and the bone implant contact was determined: Ctr (96,67%), Pla (82,22%) and Tre (15,73%), in which the Tre group presented statistically different from the other groups (p<0,05). Thus, front the employed methodology it was shown lesser bone formation and consequent reduction of the bone tissue area neo-formed at bone-implant interface.
9

Avaliação tridensional da precisão das técnicas de moldagem para próteses implantossuportadas sobre pilares alinhados e não-alinhados

Munhoz Cháves, Alejandro [UNESP] 17 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-17Bitstream added on 2014-06-13T21:06:54Z : No. of bitstreams: 1 munozchavez_a_dr_arafo.pdf: 2735655 bytes, checksum: 57a4aa3a7ba468631481a08da1143c06 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Dentre as inúmeras fases clínicas e laboratoriais de um tratamento protético, as técnicas de moldagem para próteses implantossuportadas são ainda responsáveis por grande preocupação e controvérsia entre os pesquisadores. Este estudo in vitro teve como objetivo avaliar a precisão tridimensional das moldagens para próteses sobre implantes, utilizando-se a técnica direta, variando-se os transferentes (transferentes quadrados, transferentes quadrados com extensão vestíbulo-lingual, transferentes quadrados unidos com Duralay, transferentes quadrados unidos com barra de metal e Index), o tipo de material de moldagem (Impregum Soft média viscosidade, Express consistência regular - 3M ESPE) e a disposição dos implantes (alinhados e não-alinhados). Todos os componentes protéticos utilizados foram da empresa Conexão (Conexão Sistemas de Prótese). Foi construído um modelo mestre de resina epóxica simulando um arco inferior parcialmente desdentado onde foram fixados seis análogos de pilares Micro-Unit. Foi obtido um total de cinqüenta e seis modelos, sendo sete por técnica, mais sete registros do index. Estas medições tridimensionais foram feitas por um programa (ReflexSoft 1.0) que recebia as imagens StereoMicroscópio Reflex. Os valores de distorção médios obtidos foram: Index = 25,88μm (±3,41 SD); Quadrado/ Impregum = 80,22μm (±6,36 SD); Quadrado/ Express = 80,72 μm (±4,92 SD); Quadrado Duralay/Impregum = 84,63 μm (±9,22 SD); Quadrado Duralay/ Express =78,73 μm (±6,84 SD); Quadrado hélice/ Impregum = 30,72 μm (±3,53 SD); Quadrado Hélice/ Express = 30,21 μm (±4,08 SD); Quadrado Barra Metálica/Impregum = 57,08 μm (±5,96 SD); Quadrado Barra Metálica/ Express = 50,77 μm (±4,82 SD). Os testes estatísticos utilizados foram Holm-Sidak Method e Mann-Whitney (a=0,05). Pode-se concluir que em relação às técnicas estudadas que:... / An epoxy resin cast of a partially dentulous mandibular was fabricated with 6 abutment replicas. Nine groups were formed: (Index(I); squared impression copings/ Impregum (SI), metal splinted Impression copings/ Impregum (MI), Duralay splinted impression copings/Impregum (DI), Squared modified Impression copings/ Impregum (SMI), squared impression copings/ Express (SE), metal splinted Impression copings/ Express (ME), Duralay splinted impression copings/ Express (DE) and Squared modified Impression copings/ Express (SME) with 7 casts each were formed,. The measurements were analyzed using software that received the images of a video camera coupled Reflex microscope. Data were analyzed with a 1-way analysis of variance at α <.05, followed by the Holm-Sidak Method and Mann-Whitney test (α <.05). Results. The mean values of abutment/framework interface gaps were: I group 25,88μm (±3,41 SD); SI group 80,22μm (±6,36 SD); SE group 80,71μm (±4,92 SD); MI group 57,07μm (±5,96 SD); ME group 50,76μm (±4,82 SD); DI group 84,63μm (±9,22 SD); DE group 78,73μm (±6,84 SD); HI group 30,71μm (±3,53 SD); HE group 30,21μm (±4,08 SD). No significant difference was detected between I group and HI group, and between I group and HE group (P <.05). Did not exist superiority regarding the impression material.
10

Precisão das técnicas de moldagem para próteses implantossuportadas

Del'Acqua, Marcelo Antonialli [UNESP] 08 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-08Bitstream added on 2014-06-13T21:07:01Z : No. of bitstreams: 1 delacqua_ma_dr_arafo.pdf: 1398989 bytes, checksum: 17374b239dcb2b543aaaa9731517a5ca (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Desde que não há consenso em relação a técnica de moldagem mais precisa, foi objetivo deste estudo in vitro avaliar a precisão de 1 técnica de registro (Index de resina composta) e de 5 técnicas de moldagem para próteses implantossuportadas (transferentes quadrados, quadrados jateados, quadrados com extensão lateral, quadrados unidos com Duralay e quadrados unidos com barra de metal) empregando-se 3 materiais de moldagem: silicone de polimerização por adição consistência densa/fluida com moldeira de estoque de inox, poliéter média viscosidade e silicone de polimerização por adição consistência regular com moldeira individual. Foram construídos 1 modelo mestre com 4 análogos de pilares Micro-Unit e 1 estrutura metálica. Obteve-se do modelo mestre um total de 45 modelos, sendo 5 por técnica. A estrutura metálica foi parafusada utilizando-se a técnica de mensuração de fendas por um parafuso. Estas medições foram feitas com o auxílio do programa Leica QWin que recebeu as imagens de uma câmara de vídeo acoplada a uma lupa com um aumento de 100 x. Os resultados obtidos foram analisados estatisticamente utilizando o teste de Kruskal-Wallis seguido pelo método de Dunn, !=0,05. Dentro das condições experimentais deste estudo, podese concluir que não houve diferença estatística entre: modelo mestre (31,63 !m), quadrado Impregum (38,03 μm), quadrado jateado Impregum (46,80 μm), Index (45,25 μm) e quadrado com extensão lateral Express consistência densa/fluida (51,20 μm), sendo esta a eleita. Devido aos piores resultados obtidos com as técnicas quadrado Express regular (151,21 μm) e quadrado jateado Express regular (136,59 μm), o material de moldagem Express consistência regular não deve ser empregado, sendo escolhido então para ser utilizado com moldeiras individuais o Impregum viscosidade média. Caso o cirurgião-dentista pretenda realizar... / Since there is still no consensus regarding the most accurate impression techniques, it was the purpose of this study compared the dimensional accuracy of stone index and of 5 impression techniques for implant-supported prostheses (squared impression copings, modified squared, !squared sandblasted and coated with impression adhesive, modified squared, Duralay splinted and metal splinted) using 3 impression materials: vinyl polysiloxane putty/light body with a metal stock tray and polyether medium consistency and vinyl polysiloxane regular body were used with a custom aluminum tray. A master cast with 4 parallel implant abutment analogs and a framework were fabricated. Nine groups (n=5) were tested. The gap measurement method employed was just one titanium screw tightened to the framework. Group’s measurements were analyzed using LeicaQWin software that received the images of a video camera coupled to a stereomicroscope at x100 magnification. The results were statistically analyzed with Kruskal-Wallis One Way ANOVA on Ranks test followed by Dunn's Method, !=.05. Under the conditions of this study the following conclusions could be drawn: no significant difference was detected among Master Cast (31.63 !m), Squared Impregum (38.03 !m), Sandblasted-Adhesive Squared Impregum (46.80 !m), Index (45.25 μm) and Modified Squared techniques (51.20 μm) (P=.05), being the elected. Due to the worst results with the techniques Squared Express Regular (151.21 μm) and Sandblasted-Adhesive Squared Express Regular (136.59 μm), the Express regular body impression material should not be used, and then chosen to be used Impregum Soft medium consistency with custom tray. If the dentist wishes to perform the technique with splinted copings (Metal Splinted = 68.55 !m and Duralay Splinted = 165.03 !m), the splint should be made with bars of metal. The impression technique using sandblasted-adhesive squared... (Complete abstract click electronic access below)

Page generated in 0.1126 seconds