• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 692
  • 11
  • 4
  • 3
  • 1
  • 1
  • Tagged with
  • 715
  • 345
  • 295
  • 219
  • 196
  • 175
  • 162
  • 150
  • 140
  • 139
  • 136
  • 136
  • 125
  • 117
  • 106
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Comportamento mecânico de sistemas prótese/implante em região dos elementos finitos e interferometria holográfica

Corrêa, Cássia Bellotto [UNESP] 27 March 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-27Bitstream added on 2014-06-13T19:03:10Z : No. of bitstreams: 1 correa_cb_dr_arafo_parcial.pdf: 89265 bytes, checksum: 4a9f9dd3b7ecf7d11e40eb08c7e14aa7 (MD5) Bitstreams deleted on 2015-04-01T12:51:10Z: correa_cb_dr_arafo_parcial.pdf,Bitstream added on 2015-04-01T12:51:46Z : No. of bitstreams: 1 000718624.pdf: 1088386 bytes, checksum: 7f7f102af3a1904fba4df74fc0d9c96d (MD5) / A proposta deste estudo foi analisar, por meio do método de elementos finitos (MEF), o comportamento mecânico das estruturas envolvidas em uma reabilitação implanto suportada de 4 elementos na região anterior de maxila, utilizando apenas 2 implantes, variando os posicionamentos dos implantes e o tipo de conexão protética (hexágono externo, hexágono interno e cone-Morse) e ainda validar metodologia de análise computacional por meio da interferometria holográfica, uma técnica experimental. Modelos tridimensionais baseados em um banco de tomografias computadorizadas foram criados para todas as situações estudadas (Implantes nos Incisivos Laterais - IL; Implantes nos Incisivos Centrais - IC e Implante no Incisivo Central e Incisivo Lateral - ILIC). Uma carga equivalente à 150N foi aplicada a 45° na região de cíngulo de cada elemento dentário. Para a validação da metodologia de elementos finitos por meio da interferometria holográfica, criou-se um modelo prototipado com as mesmas situações estudadas e comparou-se os deslocamentos direcionais resultantes da aplicação de 3 intensidades de força. Como resultado foi observado: o menor deslocamento da estrutura protética e maior deslocamento na estrutura óssea no grupo IC. No tecido ósseo, a tensão de von Misses localiza-se predominantemente na região cortical. O valor máximo de tensão de von Misses foi observado no implante vizinho ao cantilever no grupo ILIC. Na conexão cone Morse, o parafuso protético mostrou metade da tensão de von Misses em relação a conexão hexágono interno e hexágono externo. Comparando-se os deslocamentos direcionais nas duas metodologias, verificou-se que havia uma correlação positiva entre os resultados, porém os valores obtidos experimentalmente eram superiores aos do modelo computacional. Pode-se concluir... / The purpose of this study was to analyze, by finite element method (FEM), the mechanical behavior of structures involved in an implant supported rehabilitation of 4 elements in the anterior maxilla, using only 2 implants, varying the placements of the implants and prosthetic connection types (external hexagon, internal hexagon and Morse taper) Moreover to validate the methodology of MEF by holographic interferometry, an experimental technique. Three-dimensional models based on a database CT scans were created for all situations studied (Implants in Lateral Incisors - IL; Implants in Central Incisors IC and Implant in Central e Lateral Incisor - ILIC). An equivalent load of150N was applied at 45° in the cingulum of each tooth. To validate the finite element method by Holographic Interferometry, a prototyped model was created with the same situations studied and compared the directional displacements, resulting from the application of the 3 intensities of force. As results it was observed: the lowest prosthetic displacement structure and greater displacement in the bone structure in the IC group. In bone tissue, the von Mises stress is located predominantly in the cortical region. The maximum value of von Mises stress was observed in the implant neighboring to cantilever in the group ILIC. In Morse taper connection, the prosthetic screw showed half the von Misses stress in relation to internal and external hexagon connection. Comparing the directional displacement in both methodologies, an positive correlation between the results was found, although the experimentally values obtained were higher than those of the computational model. It can be concluded that the placement of implants and prosthetic connection type have influence in the intensity and distribution of stress/strain on the implant-supported rehabilitation of anterior... (Complete abstract click electronic access below)
92

Simulador de fadiga para teste de próteses valvulares cardíacas

Pesarini, Aldo January 2005 (has links)
Resumo: Foi construído um simulador de fadiga para próteses valvulares cardíaca, com osrecursos próprios do Laboratório de Máquinas Térmicas da Universidade Federal doParaná e materiais disponíveis no comércio local.Foi possível realizar ensaios com velocidades de até 2.540 ciclos por minuto.Com auxílio da estroboscopia é possível verificar o fechamento e a abertura totais,bem como as posições intermediárias.Foram obtidas, em escala, as curvas de pressão x tempo transprotéticas, obteve-setambém fotografias e filmagens em vídeo das próteses nas posições aberta,intermediárias e fechada, bem como suas nuances frente às alterações de fluxo epressão.Foi possível detectar, com a máquina em funcionamento, a ocorrência de problemasde fadiga nas referidas próteses após 42 milhões de ciclos.Os resultados obtidos foram compatíveis com as normas preconizadas e osresultados encontrados na literatura.
93

Efeito do Diabetes mellitus e da insulinoterapia na osseointegração estabelecida ao redor de implantes instalados em tíbia de ratos

Morais, Juliana Aparecida Najarro Dearo [UNESP] 22 November 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:28Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-11-22Bitstream added on 2014-06-13T21:06:14Z : No. of bitstreams: 1 morais_jand_dr_arafo.pdf: 1381513 bytes, checksum: 405cbb9ca3b38e574bf4c8be4a12dfeb (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O Diabetes mellitus (DM) é uma alteração metabólica que pode comprometer a estabilidade do implante dentário devido a influência no tecido ósseo. O objetivo do estudo foi avaliar o efeito do Diabetes Mellitus e da insulinoterapia na osseointegração estabelecida ao redor de implantes instalados em tíbia de ratos. Foram utilizados 80 ratos Wistar, os quais foram divididos em 4 grupos: controle de 2 meses (C2m), controle de 4 meses (C4m), diabético (D) e insulínico (I). Os implantes de superfície lisa (2,2mmx4mm) foram instalados na tíbia do rato. Após um período de 2 meses para osseointegração, o grupo C2m foi sacrificado. A indução do DM foi realizada com dose única de estreptozotocina (40mg/Kg) pela veia peniana. Os ratos do grupo I receberam insulina subcutânea (8,5 U/dia) e os demais receberam solução salina (0,9%) pela mesma via. Os níveis da glicemia plasmática foram avaliados periodicamente pelo método enzimático da glicose-oxidase. Dois meses após a indução do DM, os grupos C4m, D e I foram sacrificados. A relação do tecido ósseo com o implante foi avaliada pelas análises: radiográfica (subtração radiográfica digital); bioquímica; histométrica e torque de remoção do implante. Os dados das análises radiográfica, bioquímica e histométrica foram comparados nos grupos pelo teste ANOVA, p>0,05. Os dados da análise do torque de remoção foram comparados nos grupos pelo teste Kruskal Wallis e Friedman, p>0,05. Os resultados mostraram que o grupo D apresentou níveis de glicemia plasmática acima de 300mg/dL e significativamente mais alto do que os grupos C4m e I após a indução do DM e esta condição sistêmica foi mantida até o final do experimento. / The Diabetes mellitus (DM) is a metabolic disease that can impair the dental implant establishment by bone tissue influence. The aim of this study was evaluate the effect of Diabetes Mellitus (DM) and insulin therapy on osseointegration around dental implants. Eighty implants were placed in 80 tibiae of adult rats. After a healing period of two months, the animals were divided into four groups of 20 animals each and subdivided into 10 rats for removal torque analysis and 10 rats for histometric analysis. Group C2m was sacrificed at this time. DM was induced using 40mg/kg Streptozotocin in a diabetic group (group D) and an insulinic group (group I). During two months, group I received subcutaneous doses of 8.5 UI insulin twice a day. Groups C4m (control of 4months) and D received only saline. After two months, the animals of groups D, I and C4m were sacrificed. The glycemic control of the animals was monitored during the experiment. The relation of bone with implant was evaluated by 18 radiographic (digital subtraction radiography), bioquimic, histometric and removal torque analysis. Data obtained with radiographic, bioquimic and histometric analysis were analyzed and compared by ANOVA test, p>0,05. Data obtained with removal torque analysis were analyzed and compared by Kruskal Wallis and Friedman tests, p>0,05. The glycemic controls were within normal range for groups A, C and I and higher for group D and maintained during experiment. Greater significant values of ALP serum and Ca urinary were determined in group D after DM induction. There was a significant difference in gray shade values in the subtraction image between groups D (123±9) and I (136±5) (p<0.05) on bone formation around the implant while there were no significant differences between control groups A (127±13) and C (133±10) and insulinic group.
94

Utilização de plasma rico em plaquetas (PRP) associado a implantes intra-ósseos em mandíbulas de cães: análise histológica

Garcia, Ricardo Vieira [UNESP] 23 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:28Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-23Bitstream added on 2014-06-13T19:04:24Z : No. of bitstreams: 1 garcia_rv_dr_arafo.pdf: 835717 bytes, checksum: a0b9b5864c4b43379791c577605859ae (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi investigar através de análise histológica a influência do plasma rico em plaquetas (PRP) na neoformação óssea dos espaços peri-implantares de implantes osseointegráveis instalados em mandíbula de cães. Foram utilizados 9 cães sem raça definida. Inicialmente foram realizados exodontias dos segundos e terceiros pré-molares, bilateralmente. Após 60 dias, as áreas foram preparadas para instalação de implantes osseointegráveis, sendo que os implantes instalados do lado direito da mandíbula não receberam tratamento com PRP, servindo como controle. Para o lado esquerdo, os implantes foram instalados em associação ao PRP, caracterizando o grupo experimental. Biópsias ósseas foram obtidas nos períodos de 15, 30, 55 dias após instalação dos implantes. Pelos resultados histológicos, de modo geral, pode-se concluir que o tratamento com PRP, conforme a metodologia empregada, não favoreceu a neoformação óssea e em alguns espécimes promoveu a formação de tecido fibroso. / This study was designed to evaluate, by means of histological analysis, the effect of platelet-rich plasma (PRP) on bone formation in the interface with osseointegrated implants placed in the dog mandible. Nine dogs of mixed race were used. Initially, the second and third inferior premolars were extracted bilaterally. After 60 days, osseointegrated implants were placed. On the right side of the mandible no treatment was done and those implants served as controls. On the left side, the implants were placed in association with PRP. Bone biopsies were taken after 15, 30 and 55 days. Results showed that PRP did not enhance bone formation and favored fibrosis in some specimens.
95

Avaliação da microinfiltração bacteriana nas interfaces entre pilares e implantes

Faria, Renata [UNESP] 15 August 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-08-15Bitstream added on 2014-06-13T18:46:02Z : No. of bitstreams: 1 faria_r_dr_sjc.pdf: 634063 bytes, checksum: f7c76bd8def68214cb43267b9a499d76 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo nesta pesquisa foi avaliar a infiltração bacteriana in vitro na interface entre o pilar e o implante, comparando-se três tipos de conexões protéticas: Hexágono Externo (HE), Hexágono Interno Indexado (HII) e Cone Morse (CM). Sob condições estéreis, foi inoculada colônia de Escherichia coli na porção apical do parafuso do pilar. Após, os pilares foram fixados aos implantes com torque de 20 N/cm. Foram descartadas as amostras que apresentaram contaminação externa imediata. As amostras foram colocadas em tubos de ensaios contendo 2 ml de caldo TSB estéril. Em acompanhamento diário, por 7 dias, os caldos que se apresentaram turvos foram semeados em placa de petri com TSA e incubados em estufa bacteriológica à 37oC por 24 horas, para a observação de crescimento bacteriano. Coloração Gram foi realizada tanto no caldo quanto na colônia resultante da semeadura, para comprovação da presença de E. coli (Gram-negativo). Ao final do período, todas as amostras foram separadas, o conteúdo interno foi coletado com cone de papel e solução salina e semeado em placas de petri contendo TSA, levadas à estufa bacteriológica a 37º C por, 24 horas para verificar a viabilidade das bactérias. As amostras que não continham E.coli viáveis no seu interior foram descartadas do resultado final. Após os descartes por contaminação externa e inviabilidade, obtiveram-se os seguintes números de amostra: 38 (HE), 40 (HII) e 41 (CM). Os resultados, em % de amostras com infiltração bacteriana, foram submetidos ao teste de comparações múltiplas de proporções. As curvas de sobrevivência foram analisadas pelo método de Kaplan-Meyer e comparadas pelo teste estatístico de Log-Rank. Não houve diferença entre HE (10,53%), HII (4,88%) e CM (7,50%). As curvas de sobrevivência não diferiram entre si. A infiltração bacteriana ocorreu de modo... / The aim of this study was to evaluate, in vitro, the bacterial leakage between implant and abutment comparing three kinds of implantabutments connections: extern hexagon (EH), indexed intern hexagon (IIH) and morse-taper (MT). Under sterile controlled conditions, the tip of the abutment screw was inoculated with Escherichia coli culture and then the abutment was placed in position and tightened (20N/cm). The specimen was discarded if an external contamination of the outer surface was observed. Each specimen was incubated in a glass tube containing 2mL of sterile TSB medium at 37oC. The growth of E. Coli in the medium was registered every 24h. Once the sample showed cloudy broth, it was individually plated on TSA plates and incubated in an anaerobic chamber at 37oC for 24h, in order to observe the bacterial growth. Gram test was performed both in the medium and in the culture to certify the presence of E. Coli (Gram negative). After 7 days, each test specimen was sampled using a sterile paper point which was incubated in TSA plates and incubated in anaerobic chamber at 37oC for 24h, to verify bacterial viability. Samples that did not show bacterial viability in the end of the study were eliminated from the final results. After that, there were 38 EH samples, 40 IIH samples and 41 CM samples. The results, in %, of bacterial leakage, were statistically evaluated by multiple comparisons for proportion. The survival curves were analyzed by Kaplan-Meyer method and compared by statistical test of Log-Rank. There was no statistical difference among EH (10,53%), IIH (4,88%) e MT (7,50%). The three survival curves did not differ (p>0.005). It was conclude that the bacterial leakage occurred in a similar way for the three kinds of implant-abutment interface, no matter the assembly configuration.
96

Estudo das tensões em próteses sobre implantes esplintadas: análise pelo método da fotoelasticidade

Villa, Luiz Marcelo Ribeiro [UNESP] 10 September 2013 (has links) (PDF)
Made available in DSpace on 2014-08-13T14:50:52Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-09-10Bitstream added on 2014-08-13T18:00:08Z : No. of bitstreams: 1 000764882.pdf: 5546687 bytes, checksum: 876ee1da472cfe331f69881dd5107292 (MD5) / Propósito: O objetivo deste estudo foi avaliar a influência da esplintagem e de diferentes comprimentos de implantes na distribuição de tensões em próteses implantossuportadas, sob carregamento axial e oblíquo, por meio do método da fotoelasticidade. Materiais e métodos: Um total de 05 modelos em resina fotoelástica foi confeccionado com diferentes situações propostas, realizaram-se 400 aplicações de carga para análise. As tensões foram consideradas de forma quantitativa e qualitativa utilizando um método randomizado e simples cego. A reprodutibilidade do estudo foi avaliada usando o coeficiente de correlação intra-examinador (CCI), erro sistemático e erro casual. A análise de variância a três critérios e pós-teste de Tukey foram utilizados e, valor de p>0.05 foi adotado para analisar as principais diferenças. Resultados: As mensurações mostraram elevado coeficiente de concordância intraexaminador (CCI>0.97). A esplintagem de próteses implantossuportadas agiu favoravelmente na distribuição de tensões e na transmissão de tensões para o implante adjacente (p<0.001), quando comparado a próteses unitárias. O carregamento oblíquo foi mais prejudicial e, pontecializou a formação de tensões em implantes adjacentes (p<0.001). O aumento do comprimento foi um fator significante na avaliação dos modelos B e C (p=0.004), o modelo B apresentou maior concentração de franjas quando comparado com D e E (p<0.001). Conclusão: As próteses implantossuportadas esplintadas comportaram-se melhor biomecanicamente quando comparadas as próteses unitárias. O aumento do comprimento teve relevância na redução de tensões. O carregamento oblíquo foi mais prejudicial para a distribuição de tensões quando comparado com o carregamento axial. / Purpose: The purpose of this study was to evaluate the influence of different lengths and splinting of implants on stress distribution in implant-supported prostheses under axial and oblique loading by means of the method of photoelasticity. Materials and methods: 05 models in photoelastic resin was prepared with different proposed situations, there were 400 applications for load analysis. Tensions were considered quantitatively and qualitatively using a randomized, single blind method. The reproducibility of the study was assessed using the intra correlation coefficient, systematic error and random error. The analysis of variance to three criteria and post - Tukey tests were used, and p values > 0.05 was adopted to analyze the main differences. Results: The measurements showed a high intra-concordance coefficient (ICC> 0.97). The prosthetic implant splinting acted favorably in the distribution of stresses and strains in the transmission next to the implant (p<0.001) when compared to the unitary prosthesis. The oblique loading was more damaging and potentialized the formation of stresses in adjacent implants (p<0.001). The increase in length was a significant factor for the evaluation of the models B and C (p = 0.004), the model B had a higher concentration of fringes as compared with D and E (p<0.001). Conclusion: The prosthetic implant splinted behaved better biomechanically compared prosthetics unit. The increased length was important in reducing stress. The oblique loading was more detrimental to the stress distribution compared to axial loading.
97

Desenvolvimento e validação de um protocolo de avaliação perceptivo-auditiva da voz de deficientes auditivos usuários de implante coclear / Development and validation of a protocol for auditory-perceptual evaluation of the voice of hearing impaired individuals with cochlear implants

Ribeiro, Ana Cristina de Castro Coelho 12 December 2017 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2017. / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2018-04-11T16:49:55Z No. of bitstreams: 1 2017_AnaCristinadeCastroCoelhoRibeiro.pdf: 2832093 bytes, checksum: aaac9978b0279db63d6333cdd45066a8 (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-04-18T20:23:29Z (GMT) No. of bitstreams: 1 2017_AnaCristinadeCastroCoelhoRibeiro.pdf: 2832093 bytes, checksum: aaac9978b0279db63d6333cdd45066a8 (MD5) / Made available in DSpace on 2018-04-18T20:23:29Z (GMT). No. of bitstreams: 1 2017_AnaCristinadeCastroCoelhoRibeiro.pdf: 2832093 bytes, checksum: aaac9978b0279db63d6333cdd45066a8 (MD5) Previous issue date: 2018-04-18 / Introdução: A voz do indivíduo com deficiência auditiva que usa implante coclear tem sido amplamente caracterizada, estando comprometidos tipo de voz, ressonância, e aspectos suprasegmentares. A validação de um instrumento padronizado de avaliação de voz dessa população trará contribuições para a prática clínica e uniformização de pesquisas na área, uma vez que não há consenso na literatura sobre essas características e sobre qual instrumento de avaliação seria mais adequado. Objetivo: Desenvolver um instrumento de avaliação perceptivo-auditiva da voz do deficiente auditivo com implante coclear, estabelecendo sua validade para uso clínico e científico. Método: O instrumento proposto passou pelas etapas de validação sugeridas pelo Scientific Advisory Committee of the Medical Outcomes Trust que incluem a construção do instrumento, determinação da validade de conteúdo, confiabilidade, validade de construto, interpretabilidade e descrição de encargos. Para a validação foram utilizadas amostras de voz de 78 indivíduos com implante coclear (grupo experimental) e seus pares ouvintes (grupo controle). Os grupos foram divididos por faixa etária – crianças de 3 a 5 anos; crianças de 6 a 10 anos e adultos de 18 a 46 anos de idade. Os participantes realizaram uma gravação da vogal sustentada /a/, fala encadeada e conversa espontânea, que foram avaliadas por 3 juízes especialistas em voz com o instrumento proposto. O protocolo consiste em escalas visual-analógicas de aspectos suprasegmentares da voz, coordenação pneumofonoarticulatória, foco ressonantal, fonação, parâmetro adicional e impressão geral da qualidade vocal. Resultados: A avaliação por um comitê de especialistas e um teste piloto estabeleceram a validade de conteúdo, dando origem ao Protocolo de Avaliação de Voz do Deficiente Auditivo (PAV-DA). Medidas de confiabilidade mostraram excelente reprodutibilidade teste-reteste para a maioria dos parâmetros. Análise com a curva ROC mostrou que a avaliação perceptivo-auditiva com a vogal sustentada não diferenciou de forma robusta os implantados cocleares dos ouvintes. O mesmo ocorreu para o parâmetro “velocidade de fala” para a conversa espontânea, e este foi excluído do protocolo. Para a fala encadeada e conversa espontânea, a maioria dos parâmetros diferenciaram o grupo experimental do grupo controle com área sob a curva ≥ 0,7. Os valores de corte com máxima sensibilidade e especificidade foram de 30,5 para desvio discreto, 49,0 para desvio moderado e 69,5 para desvio intenso. O uso do protocolo demanda adequada captação do sinal sonoro, experiência clínica e familiaridade do avaliador com a voz do deficiente auditivo. Conclusão: O PAV-DA é um instrumento confiável e útil para a avaliação das particularidades da voz de indivíduos com implante coclear e pode ser utilizado em contexto clínico e científico para padronizar a avaliação e facilitar a troca de informações entre serviços. / Introduction: The voice of individuals with hearing loss who use cochlear implants has been widely described, and is compromised in terms of type of voice, resonance and suprasegmental features. The validation of a standardized instrument for voice evaluation in this population will contribute with clinical practice and standardization of research in the area, since there is no consensus in the literature about these characteristics and which instrument is more appropriate to evaluate the voice in this population. Objective: To develop an instrument for evaluating the voice of cochlear implanted individuals, establishing its validity for clinical and scientific purposes. Methods: The instrument underwent the validation steps suggested by the Scientific Advisory Committee of the Medical Outcomes Trust that include the conceptual and measurement model, determining content validity, reliability, construct validity, interpretability and burden. For validation, voice samples of 78 cochlear implanted persons (experimental group) and their hearing peers (control group) were used. The groups were divided by age range – children from 3 to 5 years; children from 6 to 10 years and adults from 18 to 46 years of age. They participated in a voice recording of the sustained vowel /a/, connected speech and conversational speech, which were rated by three voice specialists, using the proposed instrument. It consists of visualanalog scales of suprasegmental features, breath-voice coordination, resonance, phonation, additional parameter and overall impression of the voice quality. Results: Evaluation by an expert committee and a pilot test established content validity, originating the Protocol for the Evaluation of the Voice of Hearing Impaired Subjects (PEV-HIS). Reliability measures showed excellent test-retest reproducibility for the majority of the parameters. Analysis with the ROC curve showed that perceptual evaluation with the sustained vowel did not differentiate cochlear implanted and normal hearing individuals. The same occurred with the parameter “speech rate” for conversational speech, so it was excluded from the protocol. For the connected and conversation speech, the majority of the parameters differentiated the experimental group from the control group with an area under the curve ≥ 0.7. The cutoff values with maximum specificity and sensitivity were 30.5 for mild, 49.0 for moderate and 69.5 for intense deviation. The use of the protocol demands adequate capture of the sound signal, clinical experience and familiarity of the rater with the voice of hearing impaired individuals. Conclusion: The PEV-HIS is a reliable and useful tool for assessing the particularities of the voice of cochlear implanted individuals and can be used in research and clinical settings to standardize evaluation and facilitate information exchange among services.
98

Análise de corrosão e fratura de implantes/componentes protéticos de titânio comercialmente puro, após serem submetidos a ciclos de fadiga em um meio fluoretado com diferentes Ph

Sartori, Rafael [UNESP] January 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2006Bitstream added on 2014-06-13T18:57:07Z : No. of bitstreams: 1 sartori_r_me_arafo.pdf: 1051874 bytes, checksum: cefcb24c1a056b34cdd58078fbe9390f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Universidade Estadual Paulista (UNESP) / Atualmente o titânio é empregado como biomaterial devido sua biocompatibilidade e resistência à corrosão, entretanto os íons fluoretos são efetivos no processo de corrosão. O objetivo deste estudo foi analisar a influência de um meio fluoretado com diferentes pH nas propriedades mecânicas e na resistência à corrosão dos conjuntos implantes/componentes protéticos à base de Ti c.p., a partir dos testes de ciclagem mecânica, microscopia eletrônica de varredura (MEV) e dureza. Foram simulados cinco anos de uso regular de meios de higiene oral com conteúdo de 1500 ppm de NaF, com dois diferentes pH, mediante imersão das amostras nesse meio durante 184 horas. As amostras foram testadas num durômetro Micromet 2001. Os dados dos testes de dureza foram analisados pelo teste de Wilcoxon, demonstrando que as amostras sofreram influência negativa na dureza após a ação dos íons fluoreto. Entretanto, essa influência não ocorreu nos testes de ciclagem mecânica realizados em uma máquina de ensaios universais MTS-810, fixada a 100.000 ciclos, 15Hz e programada com força de fadiga a 150 N. Pela análise de MEV e EDS não foi contatado evidências de corrosão na superfície das amostras após ação de íons fluoretos, nem incorporação de íons fluoretos sobre a superfície dos conjuntos. Concluiu-se que a concentração de flúor e o pH das soluções não exerceram influência nas propriedades mecânicas e na resistência à corrosão. / Titanium has been widely used as biomaterial owing to its excellent corrosion resistance, mechanical properties and biocompatibility. However, it has been reported that fluoride-containing environments can attack titanium. The aim of this study was evaluated fluoride environments influence with different pH values in the implant/abutment sets. The implants were separated into 3 groups containing 7 implants/brand: one was submerged in acid fluoride environment (NaF 1500ppm 184h pH 5.3), one in neutral fluoride environment (NaF 1500ppm 184h pH 7.4), and other group in distillated water, simulating five years of dental hygiene. Hardness and surface texture were evaluated before and after fluoride exposition by Vickers method (500gf 30s) and scanning electron microscopy (SEM), respectively. The fatigue test was performed with 100.000 load cycles, 15 Hz and 150 N. There was decrease in hardness in implants submitted to the fluoride environment. SEM and EDS evaluation showed dark stains in all implants, irrespective of fluoride pH, resulting from pitting corrosion process. All sets supported the fatigue test until 100.000 load cycles. The results demonstrated that fluoride environment there was no influence in mechanical properties and corrosion resistence of the implant/abutment sets.
99

Avaliação macroscópica, microscópica e estereológica de implante de biomembrana em estômago de coelhos (Oryctolagus cuniculus)

Scavone, Alessandra Regina Freixo [UNESP] 19 February 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:43Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-02-19Bitstream added on 2014-06-13T19:30:11Z : No. of bitstreams: 1 scavone_arf_me_jabo.pdf: 1274995 bytes, checksum: 0e2f0c104877e36f7e533b10ff78fb89 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Neste estudo, implantou-se biomembrana de látex natural em defeito (1,5 x 1,5 cm) induzido na parede de estômago de coelhos, com o intuito de se avaliar o processo de reparação tecidual no que se refere à biocompatibilidade, capacidade de reparação e possíveis complicações. Utilizaram-se 24 coelhos, albinos, raça Nova Zelândia Branco, adultos, machos inteiros, divididos em grupos experimentais: Grupo Biomembrana Fundo (GBF), Grupo Biomembrana Corpo (GBC), Grupo Controle Fundo (GCF) e Grupo Controle Corpo (GCC). Aos quinze, 30 e 60 dias de pós-operatório, os animais foram sacrificados, para as avaliações. Macroscopicamente, aos quinze dias de pós-operatório observou-se em 100% dos animais presença de aderências na face serosa e a presença da biomembrana na face luminal. Aos 30 dias de pós-operatório 37,5% dos animais avaliados apresentaram aderências na face serosa e em 62,5% dos animais não ocorreram aderências em nenhuma estrutura. Neste mesmo período, todos os animais ainda apresentavam a biomembrana na face mucosa. Aos 60 dias de pósoperatório, 50% dos animais estudados não apresentaram aderências em nenhuma estrutura e em 50% dos animais, foi observada aderências na face serosa. Neste período, em todos os animais avaliados a biomembrana não foi encontrada. Sob microscopia de luz, no grupo Biomembrana aos quinze e 30 dias verificaram-se descontinuidade das camadas muscular e mucosa, presença de infiltrado inflamatório polimorfonuclear. Foi visualizado vasos sanguíneos e fibras musculares. Aos 60 dias as camadas mucosa, muscular estavam completamente recontituídas. No grupo GC, aos quinze e 30 dias de pós-operatório verificou-se descontinuidade da camada muscular e mucosa neoformada e presença de infiltrado inflamatório mononuclear em submucosa. Já aos 60 dias, a mucosa mostrou-se reconstituída... / In this study, biomembrane of natural latex was utilized to replace a section of face of the stomach of rabbits, with purpose of evaluation of the tissue repair process in regard of its biocompatility, scar formation ability and possible complications. Twentyfour New Zealand rabbits, adult and non-castrated males were divided in experimental groups: Biomembrane Fund Group (GBF), Biomembrane Body Group (GBC), Control Fund Group (GCF) and Control Body Group (GCC). The animals were euthanized at fifteen, 30 and 60 days of post operative, followed by analysis. Macroscopically, in fifteen days of post operative were observed in 100% of the animals presence in the serosal face, the adherences and in the luminal face the biomembrane. In 30 days of post operative 37,5% of the animals, presence in the serosal face, the adherences and 62,5% were observed in of the animals absence of the adherences. In this time, all of the animals were observed in the luminal face the biomembrane. In 60 days of post operative 50% of the animals were observed absence of the adherences, and in 50% of the animals, presence in the serosal face, the adherences. In this time the biomembrana is not in the stomach. Under light microscopy, in the Biomembrane group at fifteen and 30 days, were observed discontinuity of muscle layer and mucosa layer, presence of polimorfonuclear population of inflammatory cells. New vessels and muscle fibers were observed. In 60 days the mucosa, muscle layers were complete reconstituted. In the GP group, at 15 and 30 days of post operative were observed discontinuity of muscle layer and mucosa formed and presence of mononuclear population of inflammatory cells in submucosa. In 60 days, hypoglandular and complete layer reconstituted mucosa and muscle layers were complete reconstituted. The stereologic... (Complete abstract click electronic access below)
100

Estudo das tensões em próteses sobre implantes esplintadas : análise pelo método da fotoelasticidade /

Villa, Luiz Marcelo Ribeiro. January 2013 (has links)
Orientador: Eduardo Piza Pellizzer / Banca: Marcelo Coelho Goiato / Banca: Stefan Fiuza de Carvalho Dekon / Banca: Regina Tamaki / Banca: Sandra Lúcia Dantas de Moraes / Resumo: Propósito: O objetivo deste estudo foi avaliar a influência da esplintagem e de diferentes comprimentos de implantes na distribuição de tensões em próteses implantossuportadas, sob carregamento axial e oblíquo, por meio do método da fotoelasticidade. Materiais e métodos: Um total de 05 modelos em resina fotoelástica foi confeccionado com diferentes situações propostas, realizaram-se 400 aplicações de carga para análise. As tensões foram consideradas de forma quantitativa e qualitativa utilizando um método randomizado e simples cego. A reprodutibilidade do estudo foi avaliada usando o coeficiente de correlação intra-examinador (CCI), erro sistemático e erro casual. A análise de variância a três critérios e pós-teste de Tukey foram utilizados e, valor de p>0.05 foi adotado para analisar as principais diferenças. Resultados: As mensurações mostraram elevado coeficiente de concordância intraexaminador (CCI>0.97). A esplintagem de próteses implantossuportadas agiu favoravelmente na distribuição de tensões e na transmissão de tensões para o implante adjacente (p<0.001), quando comparado a próteses unitárias. O carregamento oblíquo foi mais prejudicial e, pontecializou a formação de tensões em implantes adjacentes (p<0.001). O aumento do comprimento foi um fator significante na avaliação dos modelos B e C (p=0.004), o modelo B apresentou maior concentração de franjas quando comparado com D e E (p<0.001). Conclusão: As próteses implantossuportadas esplintadas comportaram-se melhor biomecanicamente quando comparadas as próteses unitárias. O aumento do comprimento teve relevância na redução de tensões. O carregamento oblíquo foi mais prejudicial para a distribuição de tensões quando comparado com o carregamento axial. / Abstract: Purpose: The purpose of this study was to evaluate the influence of different lengths and splinting of implants on stress distribution in implant-supported prostheses under axial and oblique loading by means of the method of photoelasticity. Materials and methods: 05 models in photoelastic resin was prepared with different proposed situations, there were 400 applications for load analysis. Tensions were considered quantitatively and qualitatively using a randomized, single blind method. The reproducibility of the study was assessed using the intra correlation coefficient, systematic error and random error. The analysis of variance to three criteria and post - Tukey tests were used, and p values > 0.05 was adopted to analyze the main differences. Results: The measurements showed a high intra-concordance coefficient (ICC> 0.97). The prosthetic implant splinting acted favorably in the distribution of stresses and strains in the transmission next to the implant (p<0.001) when compared to the unitary prosthesis. The oblique loading was more damaging and potentialized the formation of stresses in adjacent implants (p<0.001). The increase in length was a significant factor for the evaluation of the models B and C (p = 0.004), the model B had a higher concentration of fringes as compared with D and E (p<0.001). Conclusion: The prosthetic implant splinted behaved better biomechanically compared prosthetics unit. The increased length was important in reducing stress. The oblique loading was more detrimental to the stress distribution compared to axial loading. / Doutor

Page generated in 0.0656 seconds