• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 19
  • 14
  • 3
  • Tagged with
  • 36
  • 36
  • 32
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

IRM de diffusion des fibres blanches cérébrales : développement et validation d'un objet-test / Magnetic resonance imaging of white matter : development and validation of a dedicated test-object

Filipiak, Isabelle 03 December 2014 (has links)
L'imagerie en tenseur de diffusion (DTI) est basée sur la mesure de la mobilité des molécules d'eau permettant l'analyse de la microarchitecture du tissu cérébral. Le trajet des fibres blanches peut être alors reconstruit par des méthodes de tractographie déterministes basées sur la direction principale de la diffusion. Toutefois elle repose sur des outils mathématiques complexes donnant un regard indirect sur les structures anatomiques, et sa validation est un enjeu majeur. Notre objectif a été de concevoir un objet-Test (OT) tri-Dimensionnel permettant la validation de la diffusion dans des faisceaux de fibres imitant l'organisation cérébrale. Cet OT se compose de trois modules: BOITE, SOLUTION, FIBRE réalisés en impression 3D. Il se compose de solutions de glucose et de fibres de dyneema orientées dans les trois orientations de l’espace. Nous nous sommes intéressés au développement d'une méthode de contrôle qualité des mesures quantitatives de diffusion dans le module SOLUTION. / Diffusion Tensor Imaging (DTI) is based on the measurement of water diffusion mobility in order to investigate brain microarchitecture and white fiber connectivity. The trajectory of white fibers bundles can be reconstructed by deterministic tractography methods depending on the principal direction of diffusion in tissu. However, tractography consist to complex mathematical algorithms reflecting an indirect visualization of white fibers. Our goal consisted to design a 3D phantom which imitates brain's diffusion properties, offering different degrees of diffusion mobility and imitating the organization of brain fibers. The phantom consists of three components 3D-Printing: BOX, SOLUTION, FIBER. The phantom was composed of various glucose solutions and dyneema synthetical fibers organized in all 3 directions. We developed a quality control of quantitative measurements for the SOLUTION's component. We have lead a comparison of fibers reconstruction between tractography and ground truth in FIBER's component. Results show that : ADC values were ranged on those brain values with glucose solutions; FA,
32

Planification préopératoire pour ostéotomies autour du genou : d’un modèle numérique tridimensionnel à l’industrialisation de guides patient-spécifique / Preoperative planning for osteotomies around the knee : from a 3D numerical model to patient-specific guides industrialisation

Donnez, Mathias 24 October 2018 (has links)
L’Ostéotomie Tibiale de Valgisation (OTV) par ouverture médiale est un traitement conservatif efficace dans le traitement de la gonarthrose médiale chez le patient jeune et actif présentant un défaut d’alignement du membre inférieur. Ce défaut entraine un déséquilibre dans la répartition des charges transitant dans le genou et est un facteur de risque la gonarthrose. L’objectif est de corriger l’alignement en corrigeant une déformation osseuse du tibia proximal. Une coupe osseuse médiolatérale incomplète partant du bord médial de la métaphyse tibiale et orientée vers l’articulation tibio-fibulaire permet de créer une ouverture sur le bord médial par rotation autour de la charnière latérale, épaisseur d’os non-coupée sur le bord latéral. L’importance de l’ouverture dépend de la déformation osseuse et du stade d’arthrose. La réussite de l’OTV par ouverture médiale est conditionnée par une correction précise, un montage d’ostéosynthèse stable et une charnière latérale préservée pendant l’ouverture. L’objectif de cette thèse était de proposer une méthodologie de planification préopératoire à associer à une instrumentation patient-spécifique réalisée en impression 3D. Cette instrumentation devait permettre d’appliquer la correction souhaitée dans les plans frontal et sagittal mais aussi de préserver la charnière latérale pendant la chirurgie. Nos résultats ont montré, grâce aux études in-vitro et in-vivo réalisées au cours de la thèse, que le guide de coupe patient-spécifique développé permet de reproduire avec précision la planification préopératoire en apportant de la sécurité au geste opératoire tant au niveau de la précision que de la préservation de la charnière latérale. / Medial Opening Wedge High Tibial Osteotomy (MOWHTO) is an efficient conservative surgical treatment for young and active patients with moderate medial gonarthrosis and varus lower limb malalignment. Varus malalignment unbalances load distribution in the knee, which is a gonarthrosis risk factor. MOWHTO aims to correct the lower limb alignment by correcting the proximal tibia bony deformity. Incomplete mediolateral cut is performed in the proximal tibia from the medial side of the tibial metaphysis towards the tibiofibular joint, and then opened by rotation around the lateral hinge which is the remaining uncut bone thickness on the lateral side. Amount of the opening depends on the importance of the proximal tibial deformity and on the medial gonarthrosis stage. MOWHTO success remains on precise correction, stable osteosynthesis system and lateral hinge preservation during the opening. Objective of this thesis was to propose a preoperative planning methodology to be associated with 3D printed patientspecific instrumentation. This instrumentation was intended to apply the correction chosen by the surgeon in the frontal and sagittal planes, but also to preserve the lateral hinge during the surgery. Our in-vitro and in-vivo results have shown that the developed patient-specific cutting guide make it possible to accurately reproduce the preoperative planning with security to the surgical gesture by bringing accuracy and lateral hinge preservation.
33

Vers une muséographie numérique : l’impression 3D en tant que dispositif de traduction auprès de publics malvoyants et aveugles

Bérubé, Patricia 04 1900 (has links)
No description available.
34

Compréhension de l’organisation moléculaire du poly(3-hexylthiophène) dans des mélanges polymères électrofilés et imprimés en 3D

Allen, Clarence 12 1900 (has links)
Les polymères conjugués semi-conducteurs sont des matériaux prometteurs pour des applications en optoélectronique et pour la fabrication de dispositifs de conversion d'énergie flexibles. Ils sont toutefois difficilement mis en forme en raison de la rigidité de leur structure. Le poly(3-hexylthiophène) (P3HT) est souvent utilisé comme polymère conjugué organique modèle. Sa mise en forme et ses propriétés peuvent être optimisées en l'incorporant dans une matrice polymère et en favorisant l’orientation moléculaire de ses chaînes. Cette orientation peut être induite dans un matériau lors de sa mise en forme, notamment lors de la préparation de fibres par électrofilage. Le projet vise à préparer des matériaux optimisant l'orientation du P3HT et à développer des outils pour caractériser l'organisation moléculaire du P3HT dans ces matériaux. Plus spécifiquement, la première étude consiste à comprendre l'effet de la matrice polymère sur le comportement du P3HT dans des nanofibres électrofilées. Celles-ci sont préparées en mélangeant le P3HT à une matrice polymère amorphe de poly(méthacrylate de méthyle) (PMMA) atactique ou fortement cristalline de poly(oxyde d'éthylène) (POE), et l’orientation des chaînes de P3HT est mesurée par spectroscopie Raman. Les résultats montrent que la capacité du POE à cristalliser, contrairement au PMMA, contraint les chaînes du P3HT à s'orienter le long de l’axe de la fibre, ce qui devrait améliorer ses propriétés de transport de charge. La calorimétrie différentielle à balayage et la microscopie optique et électronique à balayage permettent respectivement d'analyser les propriétés thermiques et d'imager la morphologie des nanomatériaux. La seconde étude est de développer une approche pour identifier la transition vitreuse du P3HT dans des nanofibres électrofilées et des impressions 3D composées d’un mélange P3HT-POE. Nous suivons alors l'évolution de l’état d'agrégation du P3HT par spectroscopie de fluorescence et le déplacement de sa bande Raman associée au mode d’élongation C=C sur une gamme de températures afin d'observer sa transition de phase vitreuse à l'échelle du nanoobjet individuel. Une preuve de concept est réalisée par des analyses sur des films minces à base de P3HT pour ensuite analyser les échantillons d’intérêt. Les résultats de spectroscopie Raman et de fluorescence sur les nanomatériaux de P3HT sont comparés aux analyses DSC sur les matériaux macroscopiques. Le projet améliorera d'une part notre capacité à caractériser les nanomatériaux de P3HT et, d'autre part, à en optimiser les propriétés. De manière plus générale, nos résultats conduiront à terme à une meilleure compréhension des relations structure-mise en forme-propriété-fonction des polymères conjugués, contribuant à la préparation de nouveaux matériaux électroniques organiques plus performants. / Conjugated polymers are promising semiconducting materials for applications in flexible optoelectronic and energy conversion devices. However, they are difficult to process because of the rigidity of their polymer backbone. Poly(3-hexylthiophene) (P3HT) is often used as a model organic conjugated polymer. Its processing and its properties can be improved by incorporating it into a polymer matrix and by favoring the molecular orientation of its chains. This orientation can be induced in a material during its processing, notably during the preparation of fibers by electrospinning. The project aims to prepare materials optimizing the orientation of P3HT and to develop tools to characterize the molecular organization of P3HT in these materials. More specifically, the first study consists of understanding the effect of the polymer matrix on the behaviour of P3HT in electrospun nanofibers. These nanofibers are prepared by mixing P3HT with an amorphous atactic poly(methyl methacrylate) (PMMA) or highly crystalline poly(ethylene oxide) (PEO) polymer matrix, and the orientation of the P3HT chains is measured by Raman spectroscopy. The results show that the capability of POE to crystallize, unlike PMMA, constrains the chains of P3HT to orient themselves along the fiber axis, which could improve its charge transport properties. Differential scanning calorimetry and optical and scanning electron microscopy make it possible, respectively, to analyze the thermal properties and to image the morphology of the nanomaterials. The second study is to develop an approach to identify the glass transition temperature of P3HT in electrospun nanofibers and 3D prints composed of a P3HT-PEO blend. We then follow the evolution of the aggregation state of P3HT by fluorescence spectroscopy and the shift of the Raman band associated with the C=C elongation mode over a range of temperatures to observe its glass transition temperature at the scale of the individual nanoobject. A proof of concept is first realized by carrying out analyses on thin films based on P3HT, followed by the analysis of the samples of interest. Raman and fluorescence spectroscopy results on P3HT-containing nanomaterials are compared to DSC analyses on macroscopic materials. The project will improve our ability to characterize P3HT nanomaterials and to optimize their properties. More generally, our results will ultimately lead to a better understanding of the structure-processing-property-function relationships of conjugated polymers, contributing to the preparation of new, more efficient organic electronic materials.
35

Étude des paramètres d'injection des composites de fibres naturelles et de l'amélioration des performances mécaniques du matériau pour l'impression 3D

Koffi, Agbelenko January 2021 (has links) (PDF)
No description available.
36

Évaluation biomécanique de la marche pour le développement d’orthèses plantaires imprimées en 3D : application à une population ayant les pieds plats

Desmyttere, Gauthier 07 1900 (has links)
Le pied plat flexible affecte 20-25% de la population adulte. Il est caractérisé par un affaissement anormal de l’arche longitudinale médiale en charge ainsi qu’une pronation excessive du pied. Les orthèses plantaires (OPs) représentent la prise en charge conservatrice la plus fréquemment utilisée au regard de cette pathologie. Toutefois, il existe un manque de consensus quant à leur effet bénéfique, notamment à cause de la variété d’OPs (géométrie et matériaux) utilisée. Ces dernières années, le développement des techniques d’impression 3D a permis d’innover et de faciliter la production d’OPs sur-mesure. Les réalisations actuelles ne se sont cependant limitées qu’à des formes monolithiques reposant sur la forme du pied. L’objectif de cette thèse est d'approfondir les connaissances relatives à l’impact des OPs sur la biomécanique du pied plat, afin d’aider au développement et à l’évaluation d’une OP originale imprimée en 3D. À cet égard, trois objectifs spécifiques ont été définis : (1) investiguer l’effet de la forme géométrique des orthèses plantaires chez des personnes ayant des pieds plats flexibles ; (2) quantifier l’effet de la rigidité d’OPs imprimées en 3D et celle de l’addition d’éléments anti-pronateurs novateurs sur la cinématique du pied ainsi que les pressions plantaires ; (3) évaluer l’impact d’OPs sur-mesure imprimées en 3D sur la biomécanique des membres inférieurs chez des personnes ayant des pieds plats. Par la réalisation d’une revue systématique avec méta-analyse, l’effet de la forme géométrique des OPs sur la cinématique et la cinétique du membre inférieur lors de la marche chez des personnes ayant les pieds plats a pu être déterminé. Seules les études ayant clairement décrit les modifications géométriques des OPs utilisées ont été incluses. Elles ont ensuite été divisées en cinq groupes en fonction de leur forme géométrique : avec stabilisateur d’arrière-pied médial, avec stabilisateur d’avant-pied médial, avec combinaison d’un stabilisateur d’arrière-pied et d’avant-pied médial, avec stabilisateur neutre, et avec support d’arche. La revue a ainsi mis en évidence que l’utilisation de stabilisateur médiaux était la modification géométrique la plus efficace pour réduire l’éversion de l’arrière-pied et ainsi contrôler la pronation excessive. Cependant, l'hétérogénéité dans les protocoles expérimentaux contribue à la faible évidence au regard des effets des OPs sur la biomécanique de la marche chez des personnes ayant les pieds plats. Sur la base des observations tirées de notre revue de la littérature, des stabilisateurs d’arrière-pied innovants (neutre avec extension sous l’arche) ont été développés pour être utilisés avec une OP originale imprimée en 3D. Par conséquent, l’objectif de notre deuxième étude était de quantifier l’effet de ces stabilisateurs mais aussi de déterminer l’impact de la rigidité de notre OP sur la cinématique du pied et les pressions plantaires. Pour se faire, 15 hommes en bonne santé et ayant les pieds neutres (pointure 9.5-10 US) ont été recrutés afin de s’affranchir de l’interaction possible avec une pathologie. Ainsi, il a été mis en évidence qu’une augmentation de la rigidité était associée à une réduction plus importante de l’éversion à l’arrière-pied (Différence Moyenne (DM) = -0.83°). Cette dernière a d’autant plus été réduite par l’ajout de stabilisateurs (DM = -1.15° et -2.43°). Au niveau des pressions plantaires, outre le transfert de la charge vers le médio-pied induit par le port des OPs, l’augmentation de la rigidité a contribué à accentuer les pics de pression sous l’arche et l’arrière-pied (DM de +21.6% à +31.7%). Enfin, notre troisième étude avait pour but d’évaluer l’impact d’OPs personnalisées et imprimées en 3D sur la biomécanique des membres inférieurs chez des personnes ayant des pieds plats. Pour ce faire, 19 patients recrutés par l’intermédiaire de podiatres ont reçu deux paires d’OPs sur-mesure, respectivement flexible et rigide, et ont participé à une évaluation biomécanique (cinématique, cinétique, pressions plantaires). L’augmentation de la rigidité n’a eu que peu d’effets sur la cinématique et les efforts articulaires. Elle a cependant été associée à une augmentation des pressions sous l’arche (DM = +34.4% pour la pression moyenne). L’effet de notre stabilisateur a également été quantifié. Il a été associé à une réduction significative de l'éversion à l’arrière-pied (DM = -2.0°), une réduction du moment interne d'inversion à cheville (DM = -0.03 Nm/kg), et à une légère augmentation du moment interne d’abduction au genou (DM ≈ +0.04 Nm/kg). Dans l’ensemble, le présent travail de thèse a permis de mieux saisir les mécanismes d’action des OPs sur la biomécanique des personnes ayant les pieds plats, de guider le développement d’une OP imprimée en 3D et de stabilisateurs d’arrière-pied innovants, et de confirmer que l’ajout d’éléments anti-pronateurs est essentiel afin d’observer un impact bénéfique des OPs sur le contrôle de la pronation excessive. / Flatfoot has been reported to affect around 20–25% of the adult population. It is defined by an abnormally low medial longitudinal arch upon weight bearing and an excessive foot pronation. Foot orthoses (FOs) have commonly been used as a conservative treatment to manage this deformity. However, due to the variety of FOs (geometrical designs and materials) that have been used, there is still low evidence of their beneficial effect. In recent years, the advent of 3D printing techniques has facilitated the production of innovative and customized FOs. Yet, current achievements are limited to monolithic form based on the foot shape. The objective of this thesis was to deepen the knowledge relative to FOs’ impact on flatfoot biomechanics, in order to help the development and the assessment of an original 3D printed FO. Three specific objectives were defined for this purpose: (1) investigate the effect of FOs, based on their geometrical design, in individuals with flexible flatfeet; (2) asses the effect of 3D printed FOs stiffness and newly designed anti-pronator components on foot kinematics and plantar pressures; and (3) evaluate the impact of custom 3D printed FOs on lower extremity biomechanics in individuals with flatfeet. Though a systematic and meta-analysis review, the effects FOs geometrical design on lower limb kinematics and kinetics during walking in people with flatfeet has been determined. Only studies that clearly described FOs geometrical design were included. They were then categorized into five groups based on the geometrical design of FOs: with medial rearfoot posting, with medial forefoot posting, with a combination of forefoot and rearfoot posting, with neutral rearfoot posting, and with arch support. The review highlighted that medial postings are the most effective FO feature to reduce the rearfoot eversion and therefore control excessive foot pronation. However, heterogeneity between study protocols contributes to low evidence of beneficial effects of FOs on flatfeet biomechanics during walking. Based on our literature review, innovative rearfoot postings (neutral with an extension under the medial arch) have been developed for an original 3D printed FO. Hence, our second study aimed to determine the effect of these postings as well as the stiffness of our FO on foot kinematics and plantar pressures. To do so, a study involving 15 healthy men with neutral feet (shoe size 9.5-10 US) was carried out. Healthy people were recruited to avoid any interaction with a pathology. The study showed that increasing FOs stiffness was associated to a greater reduction in rearfoot eversion (Mean Difference (MD) = -0.83°). Rearfoot eversion was further decreased when adding the rearfoot postings (MD = -1.15° and -2.43°). Looking at plantar pressures, besides a shift of the loads to the midfoot region while wearing FOs, higher peak pressures under the rearfoot and the medial arch (MD from +21.6% to +31.7%) were observed when increasing the FOs stiffness. Finally, the third study aimed at evaluating the impact of custom 3D printed FOs on lower extremity biomechanics in individuals with flatfeet. Nineteen patients, recruited by experienced podiatrists, were given two pairs of custom 3D printed FOs and participated in a biomechanical analysis (kinematics, kinetics, plantar pressures). Increasing FOs stiffness had little effects on kinematics and joint moments. However, it resulted in higher plantar pressures under the arch (MD = +34.4% for mean pressures). The addition of our rearfoot posting was associated with notable effects; it significantly reduced the eversion angle (MD = -2.0°) and inversion moment at the ankle (DM = -0.03 Nm/kg), and increased slightly the knee abduction moment (MD ≈ +0.04 Nm/kg). Overall, the present thesis has provided a better understanding on how FOs impact the biomechanics of individuals with flatfeet, helped the development of a 3D printed FO as well as innovative rearfoot postings, and confirmed that anti-pronator components are essential to observe a beneficial impact of FOs on the control of excessive foot pronation.

Page generated in 0.0817 seconds