• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 122
  • 3
  • 2
  • 1
  • 1
  • Tagged with
  • 132
  • 64
  • 27
  • 26
  • 24
  • 19
  • 16
  • 14
  • 14
  • 13
  • 12
  • 12
  • 12
  • 12
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Mistura atômica na bicamada Fe/Al induzida por feixe de íons

Vasconcellos, Marcos Antonio Zen January 1991 (has links)
Quando dirigimos nossa atenção ao deslocamento e rearranjo dos átomos de um alvo submetido à irradiação com feixe de Íons energéticos, designamos o fenômeno como Mistura Por Feixe De Íons, ou abreviadamente, IM ( do inglês "Ion Beam Mixing" ). O progresso na compreensão dos mecanismos do IM tem sido dificultado pela falta de procedimentos padronizados para a obtenção das amostras e análise dos resultados experimentais. Por outro lado, são raros os estudos sistemáticos da fenomenologia do IM em diferentes sistemas. No presente trabalho sugerimos procedimentos seguros para o estabelecimento de uma base fenomenológica mais sólida para o IM discutindo o significado, as incertezas e a relevância das grandezas físicas comumente empregadas no seu estudo. A seguir, são apresentados resultados referentes à interdifusão e formação de fases do sistema Fej Al discutindo seu significado com base em modelos propostos para os mecanismos do IM. / When the primary interest is the atomic rearrangement of a target submitted to ion beam irradiation, the phenomenon is termed Ion Beam Mixing (IM). The lack of common · procedures in producing samples and analysing experimental results has difficulted the progress in the comprehension of the basic mechanisms involved. On the other hand, systematic studies on the IM phenomenon in different systems are scarce. In the present work we suggest safe procedures to establish a more reliable basis for the IM phenomenology by discussing the role played by the physical parameters usually employed in its study. Finally, experimental results concerning the interdiffusion and phase formation in the Fe/ Al system are presented and discussed on the basis of the model mechanisms proposed to understand IM.
42

Theory of optical and magnetic properties of deep centers in semiconductors

Viccaro, Maria Helena de Azambuja January 1982 (has links)
The present work is concerned with the theory of optical and magnetic properties of deeo centers in various III-V semiconductors.
43

Estudo das propriedades locais de impurezas substitucionais de FE em PD, SC, Y, TI e ZR / Study of local properties of substitutional impurities \"FE\" to \"DP\", \"SC\", \"Y\", \"IT\" and \"ZR\"

Ângela Burlamaqui Klautau Crispino 22 June 1995 (has links)
Neste trabalho determinamos a estrutura eletrônica em torno de uma impureza substitucional de Fe nos metais de transição Pd, Sc, Y, Ti e Zr. Para realizar estes cálculos utilizamos urn método de primeiros princípios dentro da aproximação de densidade local, o RS-LMTO-ASA (\"Real Space-Linear Muffin-Tin Orbital-Atomic Sphere Approximation\'\'). Os resultados encontrados para os momentos magnéticos são comparados com outros cálculos te6ricos da literatura, e com resultados experimentais, quando existentes. Em particular, para o sistema com uma impureza de Fe em Pd analisamos os mecanismos de formação do momento magnético gigante. No caso da impureza de Fe nos hospedeiros Sc, Y, Ti e Zr, onde dois sítios distintos são observados experimentalmente, os resultados deste trabalho ajudam a identificar o sítio magnético como sendo o sítio substitucional. Calculamos também o comportamento do deslocamento isomérico e do campo hiperfino no sitio de Fe nos vários sistemas. Os valores determinados apresentam, em geral, excelente concordância com os resultados experimentais disponíveis na literatura. / In this work we use a first principles method within the local density approximation, the RS-LMTO-ASA (Real Space-Linear Muffin-Tin Orbitals-Atomic Sphere Approximation) to study the electronic structure around substitutional Fe impurities in Pd, Sc, Y, Ti and Zr hosts. We compare our results for the local magnetic moments at the impurity site with those obtained by other methods in the literature and with experimental results when available. For the substitutional Fe impurity in Pd we investigate the formation of the giant magnetic moment, which appears in this system. For the Fe impurity in Sc, Y, Ti and Zr, where two different sites for the Fe are observed experimentally, our results can help with site identification. We show beyond any doubt that the magnetic site is associated with the substitutional Fe in these hosts. Finally we also calculate the isomer shift and hyperfine contact field at the Fe impurity in all the systems. The values are in general in excellent agreement with experiment and other calculations, when available in the literature.
44

Cálculos Ab Initio da Estrutura Eletrônica e Propriedades Magnéticas de Sistemas Metálicos Bidimensionais / Ab initio calculations of the electronic structure and magnetic properties of two-dimensional metallic systems

Ângela Burlamaqui Klautau Crispino 14 March 2000 (has links)
Neste trabalho, utilizando métodos de primeiros princípios baseados no formalismo LMTO-ASA (\"Linear Muffin-Tin Orbital - Atomic Sphere Approximation\"), calculamos a estrutura eletrônica e as propriedades magnéticas de sistemas metálicos com simetria bidimensional. Usando o método de espaço real RS-LMTO-ASA, estudamos superfícies de Fe e Pd nas direções [001], [110] e [111]. Investigamos como os diferentes aspectos estruturais inerentes aos sistemas formados por camadas de Pd sobre as superfícies de Fe(001), Fe(110) e Fe(111) interferem no comportamento magnético destes sistemas, procurando explicar os diferentes alcances de polarização das camadas de Pd observados experimentalmente. Passamos, então, a estudar o comportamento magnético de defeitos em superfícies de Pd(001), Pd(110) e Pd(111). Para impurezas de Fe e Co em superfícies de Pd, obtivemos valores de momento magnético local próximos ao da saturação, e mostramos que a variação destes momentos, com o número de primeiros vizinhos em torno do defeito, é aproximadamente linear. Obtivemos uma alta polarização induzida nos átomos de Pd vizinhos às impurezas indicando a existência de um momento magnético gigante, de superfície semelhante ao observado, experimentalmente, para impurezas de Fe e Co em Pd bulk. Estudamos impurezas de Ru em superfícies de Pd, investigando um possível aumento no momento do Ru, uma vez que indícios de magnetismo foram observados experimentalmente no caso desta impureza em Pd bulk. No caso da superfície de Pd(001), investigamos também propriedades magnéticas de sistemas constituídos por aglomerados isolados de Fe embebidos na superfície de Pd e por camadas aleatórias de Fe e Co sobre essa superfície. Os resultados para camadas aleatórias foram obtidos dentro da aproximação do potencial coerente (CPA), utilizando o método \"Tight-Binding\" TB-LMTO-ASA de espaço k. Finalmente, utilizamos o método RS-LMTO-ASA para investigar o comportamento magnético de camadas de Cr em sanduíches e super-redes Fe/Cr/Fe(001), e mostramos que os efeitos da compressão da rede e da rugosidade na interface Fe-Cr podem causar uma grande redução nos momentos magnéticos das camadas de Cr mais centrais. Nossos resultados estão em boa concordância com os resultados experimentais da literatura e com os resultados teóricos obtidos por outros métodos, quando existentes. / In this work we use first principles methods based on the LMTO-ASA (\"Linear Mufün-Tin Orbital - Atomic Sphere Approximation\") formalism to study the electronic structure and magnetic properties of metallic systems with bidimensional symmetry. Using the Real Space (RS-LMTO-ASA) method we study the Fe and Pd surfaces on [001], [110] and [111]. We investigate how the different structural aspects of Pd layers on the Fe(001), Fe(110) and Fe(111) surfaces affect their own magnetic behavior, determining their relation to the experimentally observed polarization ranges of the Pd layers. We also investigate the magnetic behavior of some defects in Pd(001), Pd(110) and Pd(111) surfaces. For the case of Fe and Co impurities in Pd surfaces, we obtain for their magnetic moment values near the saturation one, and we show that these values decrease linearly as the number of nearest neighbors increases. We obtain a high polarization induced in the atoms of Pd near the impurities, which indicates the existence of a surface giant magnetic moment similar to the one experimentally observed for impurities of Fe and Co in bulk Pd. We study Ru impurities in Pd surfaces, investigating a possible increase in the Ru magnetic moment, once experimental results indicate the presence of magnetism in the case of Ru in bulk Pd. We also investigate the magnetic properties of isolated Fe clusters embedded in the Pd(001) surface, and of random layers of Fe and Co in the Pd(001) surface. The results for the random layers are obtained using the coherent potential approximation (CPA), using the k-space Tight-Binding (TB-LMTO-ASA) method. Moreover, the magnetic behavior of thin layers of Cr in Fe/Cr/Fe(001) trilayers and superlattices is studied using the RS-LMTO-ASA method. The effects of lattice compression and interface mixing are investigated, and it is shown that they can cause large reductions of the Cr magnetic moments. The values are in general in excellent agreement with experiment and other calculations, when available in the literature.
45

Linagliptina: desenvolvimento de método indicativo de estabilidade por cromatografia líquida de alta eficiência e estudos de segurança biológica

Ferreira, Raquel Balestri Heleno January 2016 (has links)
Submitted by Marcos Anselmo (marcos.anselmo@unipampa.edu.br) on 2016-09-22T20:18:29Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) RAQUEL BALESTRI HELENO FERREIRA ate AGO 2021.pdf: 1629744 bytes, checksum: 7d6690d50c0536d3f7683a73db84827d (MD5) / Approved for entry into archive by Marcos Anselmo (marcos.anselmo@unipampa.edu.br) on 2016-09-22T20:18:45Z (GMT) No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) RAQUEL BALESTRI HELENO FERREIRA ate AGO 2021.pdf: 1629744 bytes, checksum: 7d6690d50c0536d3f7683a73db84827d (MD5) / Made available in DSpace on 2016-09-22T20:18:45Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) RAQUEL BALESTRI HELENO FERREIRA ate AGO 2021.pdf: 1629744 bytes, checksum: 7d6690d50c0536d3f7683a73db84827d (MD5) Previous issue date: 2016 / A linagliptina (LGT) é um fármaco inibidor da DPP-4, da classe das gliptinas, utilizado para o controle glicêmico de diabetes mellitus tipo 2. Levando-se em conta que os fármacos utilizados no processo de produção das formulações farmacêuticas não são considerados totalmente puros, alguns Guias Regulatórios (ICH) descrevem a necessidade da quantificação do fármaco e suas impurezas de síntese. Diante disso, o objetivo do estudo é o desenvolvimento de um método por cromatografia líquida de alta eficiência (CLAE) para quantificação do fármaco e de suas três principais impurezas de síntese e o estudo de segurança biológica destas substâncias. O desenvolvimento e a validação do método para LGT e das três impurezas foram realizados por CLAE acoplada a um detector de arranjo de diodo (DAD), utilizando coluna C8 (5 μm - 4,6x100 mm), fase móvel eluída em modo gradiente, constituída de uma mistura de ácido fórmico 0,1% pH 3,5 e acetonitrila (ACN) eluída com uma rampa crescente de 10% na proporção de ACN de (0) zero ao 4 min (30% para 70%) e decrescente de 10% na proporção de ACN de 5 a 8 min (70% para 30%), vazão de 0,6 mL/min, volume de injeção de 20 μL e temperatura do forno de 30°C. Os comprimentos de onda de detecção utilizados foram 294, 278, 268 e 280 nm para LGT, impureza 1, 2 e 3, respectivamente. O método apresentou-se seletivo e específico para a LGT e as impurezas, pois não houve interferência dos produtos de degradação por Ultravioleta A, hidrólise básica (hidróxido de sódio 1,0 mol/L) e ácida (ácido clorídrico 1,0 mol/L), peróxido hidrogênio 30%, temperatura 60 °C e hidrólise básica e ácida em condições térmicas à 80 °C e dos excipientes na quantificação do fármaco. A resposta foi linear na faixa de 2,41-144,0 μg/mL (r = 0,9996) para a LGT e na faixa de 0,06-3,6 μg/mL para as impurezas testadas (r = 0,9963, 0,9994 e 0,9991 para impureza 1, 2 e 3, respectivamente). O método demonstrou exatidão, com teores de recuperação de 99,79, 93,12, 92,92 e 93,99% para a LGT e impureza 1, 2 e 3, respectivamente. A precisão intra e inter-dia foi satisfatória (RSD 1,36, 4,14, 3,50 e 4,08% para a LGT e impureza 1, 2 e 3, respectivamente) e a robustez não apresentou diferenças significativas com pequenas alterações nas condições analíticas (pH, fase móvel, temperatura, fluxo e detector). A cinética de degradação em condição alcalina associada a temperatura de (80 ºC), apresentou resultados de primeira ordem. A avaliação da segurança biológica foi realizada por meio da citotoxicidade, mutagenicidade e genotoxicidade através dos testes de viabilidade celular, micronúcleo e cometa, respectivamente. Nos testes de segurança biológica a LGT apresentou-se apenas citotóxica na concentração 10 vezes superior a concentração plasmática máxima, enquanto as impurezas 1 e 3 apresentaram-se citotóxica, mutagênica e genotóxica em uma concentração equivalente a 10% concentração plasmática máxima do fármaco e a impureza 2 evidenciou sua citotoxicidade e genotoxicidade na concentração equivalente a 10% da concentração plasmática máxima do fármaco. De acordo com os resultados obtidos, pode-se observar que o método proposto foi indicativo de estabilidade por CLAE para LGT e ainda demonstrou-se adequado para análise quantitativa das impurezas de síntese do fármaco. Além disso, evidenciou-se que a LGT e as impurezas de síntese estão em conformidade com os testes de segurança biológica empregados, desde que utilizadas nas concentrações adequadas. / Linagliptin (LGT) is an inhibitor of DPP4 used for glycemic control of type 2 mellitus diabetes. Since the drugs used in the production process of the pharmaceutical formulations are not considered totally pure, the Regulatory Guides describing the need of the drug quantification and impurities potentials. Therefore, the aim of this study was to develop a method by highperformance liquid chromatography to quantify the drug and three potential synthetic impurities and biological safety studies. The development and validation of the method for LGT and the three impurities were carried out by HPLC coupled to a photodiode array detector. The chromatographic separation was performed in a RP8 column (150 x 4.6 mm, 5 μm), at 30°C. The separation was performed by means of a linear gradient elution (eluent A: formic acid 0.1% pH 3.5; eluent B: acetonitrile). The gradient obeys the following sequence: 3070% of B (0 - 4 minutes) and 7030 of B (4,01 - 8 minutes) at a flowrate of 0.6 mL min1 and run time of 10 minutes. The injection volume was 20 μL and detection at 294, 278, 268 e 280 nm for LGT, impurity 1, 2 and 3, respectively. The method showed selectivity and specific for the LGT and synthetic impurities, therefore no interference of degradation products (UV-A, basic hydrolysis (sodium hydroxide 1.0 mol L1) and acid (hydrochloric acid 1.0 mol L1), peroxide (30%), temperature (60 ° C) and acidic and basic hydrolysis under thermal conditions (80° C)) and the excipients in the quantification of the drug. The response was linear from 2.41 to 144.0 μg mL1 (r = 0.9996) for the LGT and in the range of 0.06 to 3.6 μg mL1 (r = 0.9963, 0.9994 and 0.9991 for impurity 1, 2 and 3, respectively ). The method showed accuracy, with recovery levels of 99.79, 93.12, 92.92 and 93.99% for LGT and impurity 1, 2 and 3, respectively. The intra and inter-day precision was suitable (RSD 1.36, 4.14, 3.50 and 4.08% for LGT and impurity 1, 2 and 3, respectively) and the robustness showed no significant differences with small changes in the analytical conditions (pH of the mobile phase, temperature, flow-rate and detector). The kinetics of degradation in alkaline conditions associated with temperature (80° C), showed results of the first order. The evaluation of the biological was performed by cytotoxicity, mutagenicity and genotoxicity through the cell viability test, micronucleus and comet, respectively. In biological safety testing LGT had only cytotoxic activity at a concentration of 10 times the maximum plasma concentration, while the impurity 1 and 3 set out cytotoxic, mutagenic and genotoxic in a concentration equivalent to 10% maximum plasma concentration of the drug and impurity 2 showed cytotoxicity and genotoxicity in concentration equivalent to 10% of the maximum plasma concentration of the drug. According to the results, it can be seen that the proposed method by HPLC is stability-indicating and suitable for quantitative analysis of the drug and synthetic impurities. Furthermore, it was observed that the LGT and synthetic impurities are in accordance with biological safety studies, if they are used in appropriate concentration.
46

Estudio experimental y de cálculos de primeros principios del semiconductor Sc<SUB>2</SUB>O<SUB>3</SUB> dopado con <SUP>111</SUP>In &rarr; <SUP>111</SUP>Cd, <SUP>181</SUP>Hf &rarr; <SUP>181</SUP>Ta y <SUP>44</SUP>Ti &rarr; <SUP>44</SUP>Sc

Richard, Diego January 2009 (has links)
El presente trabajo pretende contribuir a profundizar el entendimiento de propiedades estructurales, electrónicas y magnéticas en sistemas huésped-impureza, mediante el empleo combinado de estas técnicas experimentales y teóricas aplicadas al estudio del semiconductor Sc2O3 puro y dopado con 111 Cd y 181 Ta, realizando además una comparación con otro modelo más sencillo como el de cargas puntuales (PCM, por sus siglas en inglés). Esta modalidad de trabajo permitirá analizar la aplicabilidad de aproximaciones introducidas en la DFT, y las razones por las que en ciertos casos funcionan los modelos más sencillos. En este trabajo mostramos como cálculos de primeros principios pueden resultar esenciales para una correcta asignación de las interacciones hiperfinas
47

Determinação multielementar de elementos traços em radiofármacos produzidos na Diretoria de Radiofarmácia por espectrometria de emissão por plasma / Multielemental determination of trace elements in radiopharmaceuticals produced at the radiopharmacy center using icp-oes technique

Angélica Tamião Tavares 29 November 2013 (has links)
Os radiofármacos são preparações farmacêuticas, que contém radionuclídeo, utilizados em medicina nuclear. O objetivo desse trabalho foi estudar as concentrações de elementos químicos, principalmente metais, em amostras de radiofármacos ALBUMINA-TEC, DEX 70-TEC, DEX 500-TEC, DISIDATEC, DMSA-TEC, EC-TEC, DTPA-TEC, FITATO-TEC, GHA-TEC, MDP-TEC, MIBI-TEC, PIRO-TEC, FDG-Flúor-18, GERADOR IPEN-TEC, IODO-131 SOLUÇÃO. As análises foram realizadas em equipamento Vista MPX simultâneo ICP-OES (Agilent, Australia). A validação do método foi realizado segundo os critérios descritos na RDC n° 899: Guia para validação de métodos analíticos e bioanalíticos de 29 de maio de 2003. De acordo com a Farmacopeia Americana (USP), as impurezas elementares com potencial toxicidade devem ser quantificados. Uma proposta de revisão USP 35 introduz a técnica de espectrometria de emissão atômica para a análise de elementos. Os resultados de validação das análises no ICP-OES indicam a necesidade de controle da limpeza e manutenção do equipamento, alterações do sample uptake delay e avaliação da robustez com as linhas do Mg. As curvas analíticas e faixas de concentracões analisadas foram lineares com r > 0,99. Os resultados de DPR foram abaixo de 5%. Todos os resultados dos parâmetros avaliados estão de acordo com os estabelecidos pela ANVISA. / Radiopharmaceuticals are pharmaceutical preparations containing radionuclide used in nuclear medicine. The aim of this work was to study the concentrations of chemical elements, especially metals, in samples of radiopharmaceuticals ALBUMINA-TEC, DEX 70-TEC, DEX 500-TEC, DISIDA-TEC, DMSA-TEC, EC-TEC, DTPA-TEC, FITATO-TEC, GHA-TEC, MDP-TEC, MIBI-TEC, PIRO-TEC, FDG-FLÚOR-18, GERADOR IPEN-TEC, IODO-131 SOLUÇÃO. The analyses were carried out simultaneously in an ICP-OES Vista MPX (Agilent). The method validation was performed according to the criteria defined in RDC No. 899 : Guide for validation of analytical and bioanalytical methods for May 29, 2003 of the ANVISA. According to the U.S. Pharmacopeia (USP), the elemental impurities with potential toxicity must be quantified. A proposed revision to USP 35 introduces the technique of atomic emission spectrometry for the analysis of elements. The validation results of the ICP- OES analyzes indicated the necessary to control the cleaning and maintenance of equipment, changes in sample uptake delay and robustness evaluation with the lines of Mg. The analytical curves and concentration ranges analyzed were linear with r > 0.99. The results of DPR were below 5%. All the parameters were below the established by ANVISA .
48

Estudo da difusão de Ag e Al em [alfa]-Ti utilizando as técnicas de espectrometria de retroespalhamento Rutherford e reação nuclear

Araújo, Leandro Langie January 2000 (has links)
O objetivo da presente dissertação é o estudo da difusão de Ag e Al em uma matriz de α-Ti. Sua motivação principal se origina do fato de haver na literatura resultados contraditórios sobre o comportamento difusional desses elementos. Além disso, este estudo é necessário para dar continuidade à investigação sistemática da difusão de impurezas substitucionais em α-Ti, que vem sendo realizada pelo grupo de implantação iônica, a fim de estabelecer uma relação entre tamanho, valência e solubilidade dos elementos e seus coeficientes de difusão. A dependência do coeficiente de difusão com a temperatura para ambos elementos foi estudada nos intervalos de temperatura de 823 a 1073 K para a Ag e 948 a 1073 K para o Al. No caso da Ag foi usada a técnica de RBS para determinar os perfis de concentração, a qual tem uma alta resolução em profundidade (tipicamente 10nm), o que permite a determinação das baixas difusividades esperadas no presente experimento ( D ≤ 10-7 m2/s). No caso do Al foi usada a técnica de NRA, que preenche os mesmos requisitos citados anteriormente, com uma resolução em profundidade de aproximadamente 10 Å. As medidas realizadas mostraram que, para ambos os casos, os coeficientes de difusão seguem uma representação linear de Arrhenius. Foram encontrados os seguintes parâmetros característicos de difusão: Do = (1 ± 0,75) x10-4 m2s-1 e Q = 279 ± 6 kJ/mol para a Ag e Do = (1,4 ± 1,2) x10-2 m2s-1 e Q = 326 ± 10 kJ/mol para o Al, os quais são típicos de um comportamento substitucional normal. A comparação desse trabalho com trabalhos prévios não mostra evidência de relacionamento entre tamanho, valência e solubilidade dos elementos e seus coeficientes de difusão.
49

Determinação da posição reticular de F em Si

Bernardi, Fabiano January 2006 (has links)
Neste trabalho, estudamos a posição de átomos de F na estrutura cristalina do Si. As amostras foram pré-amorfizadas utilizando um feixe de Si de 200 keV e, após, implantadas com F. Então recristalizamos a camada amorfa através do processo de Epitaxia de Fase Sólida (EFS). Empregamos as técnicas de Espectrometria de Retroespalhamento Rutherford, na condição de canalização iônica, e de Análise por Reação Nuclear (NRA), através da reação ressonante ( ) O p F 16 19 , αγ , à 5 , 340 keV, para determinar a posição dos átomos de F e, depois, reproduzimos os resultados experimentais através do programa de simulação computacional chamado Simulação Adaptada de Canalização de Íons Rápidos em Sólidos (CASSIS - Channeling Adapted Simulation of Swift Ions in Solids). Os resultados obtidos apontam para duas possíveis combinações lineares distintas de sítios. Uma delas concorda com a proposta teórica de Hirose et al. (Materials Science & Engineering B – 91-92, 148, 2002), para uma condição experimental similar. Nessa configuração, os átomos de F estão na forma de complexos entre átomos de flúor e vacâncias (F-V). A outra combinação ainda não foi proposta na literatura e também pode ser pensada como um tipo de complexo F-V.
50

Determinação de impurezas em cobre eletrolítico por espectrometria de massas com plasma indutivamente acoplado

Barbour, Reinaldo January 2011 (has links)
102f. / Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2013-03-27T17:17:03Z No. of bitstreams: 1 Tese doutorado final Reinaldo Barbour.pdf: 1224301 bytes, checksum: b37e38d9ef21943dba24e8f3638efbcd (MD5) / Approved for entry into archive by Ana Hilda Fonseca(anahilda@ufba.br) on 2013-04-19T13:16:36Z (GMT) No. of bitstreams: 1 Tese doutorado final Reinaldo Barbour.pdf: 1224301 bytes, checksum: b37e38d9ef21943dba24e8f3638efbcd (MD5) / Made available in DSpace on 2013-04-19T13:16:36Z (GMT). No. of bitstreams: 1 Tese doutorado final Reinaldo Barbour.pdf: 1224301 bytes, checksum: b37e38d9ef21943dba24e8f3638efbcd (MD5) Previous issue date: 2011 / CAPES / A determinação de impurezas em cobre eletrolítico, na faixa de μg g-1 e sub μg g-1, é muito importante para caracterizar o cobre de alta pureza (99,99%). As suas propriedades físicas e químicas como maleabilidade, condutividade térmica e elétrica são fundamentais nas aplicações industriais nos setores de eletricidade e eletrônica. Metais e ametais como Ag, As, Bi, Co, Cr, Fe, Mn, Ni, Pb, Sb, Se, Sn,Te e Zn modificam estas propriedades deteriorando sua maleabilidade e condutividade. A espectrometria de massas com plasma indutivamente acoplado (ICP-MS) tem sido muito empregada para a determinação elementar, em amostras industriais, devido às suas características, principalmente as relacionadas com a capacidade multielementar, a rapidez e a alta sensibilidade. As principais desvantagens da técnica são as interferências isobáricas e poliatômicas, além daquelas relacionadas à matriz. Este trabalho teve por objetivo estabelecer um procedimento analítico validado para a determinação de elementos contaminantes por ICP-MS em amostras de cobre eletrolítico, de forma a garantir os limites de quantificação exigidos para a certificação do cobre. O equipamento empregado foi operado nos modos padrão e CCT (célula de colisão que utiliza 1,0% (v/v) NH3 em He balanço) com comutação automática. As amostras e materiais de referência certificados foram digeridos, em triplicata, empregando bloco aquecedor, seguindo o procedimento: 10  1 mg de amostra com 2 mL de HNO3 1:1 (v/v) à 70ºC. A diluição final foi de 5000x, o que contribui para minimização dos efeitos de matriz provenientes da alta concentração dos íons de cobre (~200 ug g-1). Os isótopos selecionados no modo normal de operação do equipamento foram: 55Mn, 59Co, 60Ni, 68Zn, 75As, 107Ag, 118Sn, 121Sb, 128Te, 208Pb e 209Bi. Para o modo com célula de colisão, os isótopos foram: 52Cr, 56Fe, 57Fe, 77Se e 78Se. A faixa linear estudada foi de 0,01 a 2 ng g-1. Os limites de quantificação encontrados (μg g-1 no cobre) foram: Ag (0,05), As (0,2), Bi (0,05), Co (0,1), Cr (0,2), Fe (0,5), Mn (0,2), Ni (0,2), Pb (0,1), Sb (0,2), Se (0,2), Sn (0,2),Te (0,1) e Zn (0,5). A exatidão foi avaliada pela analise dos seguintes materiais de referência certificados: BAM-M381, BAM-M382, BAM-M383, BAM-M384 (Pure Copper, BAM; Federal Institute for Materials Research and Testing) e NIST 495, NIST 496, NIST 457 (National Institute of Standards and Technology) sendo que a maioria das recuperações obtidas foram entre 80 e 120% e os %RSD menores que 10% (Se < 20%). O efeito de matriz foi avaliado através das técnicas de calibração: calibração externa com padrões internos, calibração com adição de analito e calibração com uso dos CRMs e não houve diferença significativa dos resultados. A técnica DC-ARC OES foi empregada para comparação dos resultados. A avaliação dos resultados das amostras reais de bobinas foi feita por meio de ensaios interlaboratoriais e do critério z score. Por este critério, a maioria dos resultados obtidos foram considerados excelentes. Pode-se concluir que o método proposto, empregando ICP-MS, é adequado para determinação multielementar / Salvador

Page generated in 0.0465 seconds