• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 36
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 38
  • 16
  • 12
  • 11
  • 9
  • 9
  • 7
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Estudo da influência das redes locais sem-fio IEEE 802.11g na qualidade de voz estimada pelo modelo e / A Study of the influence of IEEE 802.11g wireless local networks on the voice quality estimated by the e-model

Marshall, Guilherme January 2006 (has links)
Este trabalho apresenta uma análise completa da qualidade de voz esperada em serviços de VoIP quando prestados sobre a plataforma WLAN IEEE 802.11g. Diferentemente da maior parte da literatura, este estudo complementa as informações de atraso, variação do atraso e taxa de perda dos pacotes, com um modelo analítico de avaliação de qualidade de voz proposto pela ITU-T, o Modelo E. Desta forma, todos os fatores modelados como perceptíveis pelos usuários do serviço telefônico são considerados simultaneamente, gerando, por fim, resultados correspondentes à escala de avaliação subjetiva da qualidade de voz MOS, que qualifica a opinião média em: “muito satisfeitos”, “satisfeitos”, “alguns insatisfeitos”, “muitos insatisfeitos”, “quase todos insatisfeitos” e “não recomendado”. O código do simulador NS-2 foi expandido para prover todas as funcionalidades requeridas neste trabalho. Com ele, diferentes cenários de aplicação foram simulados utilizando três dos codificadores de voz mais utilizados atualmente, o G.723.1, o G.729a e o G.711 (com e sem PLC). A funcionalidade centralizada da camada MAC IEEE 802.11, o PCF, também foi estudada, tendo os parâmetros referentes ao período entre repetições do CFP e à máxima duração do mesmo analisados e ajustados de modo a prover o melhor desempenho. Experimentos similares foram realizados para a função DCF, permitindo então uma comparação direta entre os dois modos de operação do nível MAC. Além disso, ensaios considerando outros tráfegos menos prioritários (estações de dados) foram realizados com o intuito de caracterizar a capacidade dos sistemas em diferenciar ambos os tráfegos. / This work is intended to provide a complete evaluation of the voice quality obtained in IEEE 802.11g WLAN environments. In contrast to the major literature, this dissertation complements the traditional network metrics, as delay, jitter and loss rate, with an analytical model for voice quality evaluation created by ITU-T, named E Model. With this model, all factors able of affecting the user’s perception of quality in a telephony service are simultaneously considered to reflect the subjective voice quality scale MOS, which rates the mean opinion as follow: “very satisfied”, “satisfied”, “some user satisfied”, “many users dissatisfied”, “nearly all user dissatisfied” and, “not recommended”. An extension to the NS-2 simulator source code has been developed to provide all the features required by this study. With this ‘customized simulator’, several scenarios have been analyzed considering three of the most important vocoders in the market today, G.723.1, G.729a, and G.711 (with and without PLC). Moreover, the centralized scheme for the IEEE 802.11 MAC, called PCF, has been studied to show the effect of the CFP repetition interval and the CFP maximum duration on its upper bound limit of simultaneous voice calls. Similar experiments have been carried out for the DCF MAC functionality, allowing these medium access modes to have their performance directly compared against each other. Finally, scenarios with low priority traffic (data traffic) have been created to help describing the ability of both MAC functions to deal with traffic differentiation.
32

Estudo da influência das redes locais sem-fio IEEE 802.11g na qualidade de voz estimada pelo modelo e / A Study of the influence of IEEE 802.11g wireless local networks on the voice quality estimated by the e-model

Marshall, Guilherme January 2006 (has links)
Este trabalho apresenta uma análise completa da qualidade de voz esperada em serviços de VoIP quando prestados sobre a plataforma WLAN IEEE 802.11g. Diferentemente da maior parte da literatura, este estudo complementa as informações de atraso, variação do atraso e taxa de perda dos pacotes, com um modelo analítico de avaliação de qualidade de voz proposto pela ITU-T, o Modelo E. Desta forma, todos os fatores modelados como perceptíveis pelos usuários do serviço telefônico são considerados simultaneamente, gerando, por fim, resultados correspondentes à escala de avaliação subjetiva da qualidade de voz MOS, que qualifica a opinião média em: “muito satisfeitos”, “satisfeitos”, “alguns insatisfeitos”, “muitos insatisfeitos”, “quase todos insatisfeitos” e “não recomendado”. O código do simulador NS-2 foi expandido para prover todas as funcionalidades requeridas neste trabalho. Com ele, diferentes cenários de aplicação foram simulados utilizando três dos codificadores de voz mais utilizados atualmente, o G.723.1, o G.729a e o G.711 (com e sem PLC). A funcionalidade centralizada da camada MAC IEEE 802.11, o PCF, também foi estudada, tendo os parâmetros referentes ao período entre repetições do CFP e à máxima duração do mesmo analisados e ajustados de modo a prover o melhor desempenho. Experimentos similares foram realizados para a função DCF, permitindo então uma comparação direta entre os dois modos de operação do nível MAC. Além disso, ensaios considerando outros tráfegos menos prioritários (estações de dados) foram realizados com o intuito de caracterizar a capacidade dos sistemas em diferenciar ambos os tráfegos. / This work is intended to provide a complete evaluation of the voice quality obtained in IEEE 802.11g WLAN environments. In contrast to the major literature, this dissertation complements the traditional network metrics, as delay, jitter and loss rate, with an analytical model for voice quality evaluation created by ITU-T, named E Model. With this model, all factors able of affecting the user’s perception of quality in a telephony service are simultaneously considered to reflect the subjective voice quality scale MOS, which rates the mean opinion as follow: “very satisfied”, “satisfied”, “some user satisfied”, “many users dissatisfied”, “nearly all user dissatisfied” and, “not recommended”. An extension to the NS-2 simulator source code has been developed to provide all the features required by this study. With this ‘customized simulator’, several scenarios have been analyzed considering three of the most important vocoders in the market today, G.723.1, G.729a, and G.711 (with and without PLC). Moreover, the centralized scheme for the IEEE 802.11 MAC, called PCF, has been studied to show the effect of the CFP repetition interval and the CFP maximum duration on its upper bound limit of simultaneous voice calls. Similar experiments have been carried out for the DCF MAC functionality, allowing these medium access modes to have their performance directly compared against each other. Finally, scenarios with low priority traffic (data traffic) have been created to help describing the ability of both MAC functions to deal with traffic differentiation.
33

Novas tecnologias para detecção infravermelha de alto desempenho / Novel Technologies for High Performance Infrared Detection

Marcel Santos Claro 26 June 2017 (has links)
Neste trabalho, foi estudado a aplicação de novas heteroestruturas semicondutoras para detecção de radiação na região do infravermelho médio. Pontos quânticos de submonocamada, detectores de cascateamento quântico e pontos quânticos de InAlAs foram testados como opção para corrigir as deficiências em responsividade, corrente de escuro e temperatura de operação, comuns nas heteroestruturas convencionais baseadas em poços quânticos e pontos quânticos de InAs obtidos no regime de crescimento Stranski-Krastanov. Também foi projetado, fabricado e testado um circuito eletrônico de leitura de sinal misto para integração com matrizes de sensores e produção de imagens. Esse tipo de circuito possui uma série de vantagens em relação aos dispositivos convencionais que costumam ser completamente analógicos. / In this work, we studied the application of new types of semiconductor heterostructures for mid-infrared detection. Submonolayer quantum dots (SML-QDs), quantum-cascade detectors (QCDs) and InAlAs quantum dots were tested as an option to circumvent the common shortcomings of responsivity, dark current and operating temperature of the usual heterestructures based on quantum wells (QWs) and InAs Stranski-Krastanov quantum dots. We also designed, fabricated and tested a mixed-signal read-out circuit aiming the fabrication of focalplane arrays (FPAs) for applications to infrared imaging. This kind of architecture has several advantages over a fully analog design.
34

Estudo da influência das redes locais sem-fio IEEE 802.11g na qualidade de voz estimada pelo modelo e / A Study of the influence of IEEE 802.11g wireless local networks on the voice quality estimated by the e-model

Marshall, Guilherme January 2006 (has links)
Este trabalho apresenta uma análise completa da qualidade de voz esperada em serviços de VoIP quando prestados sobre a plataforma WLAN IEEE 802.11g. Diferentemente da maior parte da literatura, este estudo complementa as informações de atraso, variação do atraso e taxa de perda dos pacotes, com um modelo analítico de avaliação de qualidade de voz proposto pela ITU-T, o Modelo E. Desta forma, todos os fatores modelados como perceptíveis pelos usuários do serviço telefônico são considerados simultaneamente, gerando, por fim, resultados correspondentes à escala de avaliação subjetiva da qualidade de voz MOS, que qualifica a opinião média em: “muito satisfeitos”, “satisfeitos”, “alguns insatisfeitos”, “muitos insatisfeitos”, “quase todos insatisfeitos” e “não recomendado”. O código do simulador NS-2 foi expandido para prover todas as funcionalidades requeridas neste trabalho. Com ele, diferentes cenários de aplicação foram simulados utilizando três dos codificadores de voz mais utilizados atualmente, o G.723.1, o G.729a e o G.711 (com e sem PLC). A funcionalidade centralizada da camada MAC IEEE 802.11, o PCF, também foi estudada, tendo os parâmetros referentes ao período entre repetições do CFP e à máxima duração do mesmo analisados e ajustados de modo a prover o melhor desempenho. Experimentos similares foram realizados para a função DCF, permitindo então uma comparação direta entre os dois modos de operação do nível MAC. Além disso, ensaios considerando outros tráfegos menos prioritários (estações de dados) foram realizados com o intuito de caracterizar a capacidade dos sistemas em diferenciar ambos os tráfegos. / This work is intended to provide a complete evaluation of the voice quality obtained in IEEE 802.11g WLAN environments. In contrast to the major literature, this dissertation complements the traditional network metrics, as delay, jitter and loss rate, with an analytical model for voice quality evaluation created by ITU-T, named E Model. With this model, all factors able of affecting the user’s perception of quality in a telephony service are simultaneously considered to reflect the subjective voice quality scale MOS, which rates the mean opinion as follow: “very satisfied”, “satisfied”, “some user satisfied”, “many users dissatisfied”, “nearly all user dissatisfied” and, “not recommended”. An extension to the NS-2 simulator source code has been developed to provide all the features required by this study. With this ‘customized simulator’, several scenarios have been analyzed considering three of the most important vocoders in the market today, G.723.1, G.729a, and G.711 (with and without PLC). Moreover, the centralized scheme for the IEEE 802.11 MAC, called PCF, has been studied to show the effect of the CFP repetition interval and the CFP maximum duration on its upper bound limit of simultaneous voice calls. Similar experiments have been carried out for the DCF MAC functionality, allowing these medium access modes to have their performance directly compared against each other. Finally, scenarios with low priority traffic (data traffic) have been created to help describing the ability of both MAC functions to deal with traffic differentiation.
35

Vasodilatação induzida pelo calor através de dispositivo portátil no leito na insuficiência cardíaca descompensada / Thermal vasodilation using a portable infrared thermal blanket in decompensated heart failure

Lima, Marcelo Villaça 24 March 2014 (has links)
Fundamento: medidas adjuvantes têm sido propostas para o tratamento de pacientes com insuficiência cardíaca, algumas não farmacológicas, como o uso do calor. Apesar dos resultados positivos para pacientes clinicamente estáveis, não existem trabalhos relacionados ao tratamento com calor na fase descompensada da insuficiência cardíaca em pacientes em uso de drogas vasoativas. Objetivos: avaliar os efeitos hemodinâmicos agudos do calor aplicado através da manta térmica em pacientes com insuficiência cardíaca descompensada (ICD) refratária. Para isso foi estabelecido como desfechos o aumento do índice cardíaco e a redução da resistência vascular sistêmica no primeiro dia de seguimento. Como objetivo secundário, avaliar se sessões repetidas de calor por cinco dias consecutivos promoveria ou sustentaria os efeitos hemodinâmicos obtidos agudamente e, se reduziria os níveis de BNP ao longo do seguimento. Métodos: ensaio clínico randomizado aberto, prospectivo, com grupo controle em pacientes portadores de ICD. O estudo foi dividido em duas fases. Na primeira fase foram estudados pacientes em um único dia e foi avaliado o efeito agudo do calor antes e após a intervenção. Na segunda fase o calor foi avaliado através de sessões diárias por cinco dias consecutivos. Foi utilizada a manta térmica por radiação infravermelha para o aquecimento dos pacientes. As medidas hemodinâmicas foram avaliadas por método invasivo através do cateter de Swan-Ganz e de maneira não invasiva pelo método de modelflow. Os pacientes estavam em uso de inotrópico endovenoso contínuo, no perfil hemodinâmico C segundo a classificação clínico-hemodinâmica de Stevenson e foram considerados refratários após tentativa de retirada da droga vasoativa sem sucesso. A população do estudo foi dividida em 2 grupos: grupo T (termoterapia) e grupo C (controle). O grupo T foi submetido à vasodilatação térmica através da manta térmica na temperatura de 50°C por 40 minutos adicionalmente ao tratamento medicamentoso. Os pacientes do grupo C mantiveram o tratamento medicamentoso e a manta térmica foi posicionada da mesma maneira por 40 minutos, porém desligada. Análise estatística: as variáveis foram analisadas pelo teste exato de Fisher ou razão de verossimilhança. A normalidade foi avaliada com o teste de Komogorov-Smirnov. As variáveis quantitativas foram apresentadas por média e desvio padrão. As médias foram avaliadas com análise de variância para medidas repetidas (ANOVA). Quando significante, utilizou-se contrastes para discriminar as diferenças entre os momentos. As medidas avaliadas em um único momento foram comparadas com teste t-Student. Foi utilizado o coeficiente de correlação de Pearson para a análise da correlação entre as medidas. Foram considerados estatisticamente significantes os valores de p < 0,05. Resultados: entre outubro de 2007 e abril de 2013, 165 pacientes foram avaliados para possível elegibilidade. Destes, 12 pacientes recusaram participar do estudo e 105 foram excluídos pelos critérios de exclusão. Foram incluídos 48 pacientes, entretanto, 10 pacientes foram excluídos prérandomização. Foram avaliados inicialmente 8 pacientes que foram submetidos a sessões de calor para segurança e validação do método e 30 pacientes foram randomizados até o término do estudo. No total, 38 pacientes foram estudados. Não houve diferença nas características basais entre os grupos estudados. Na primeira fase foram avaliados 38 pacientes, pré e pós-intervenção. A vasodilatação térmica foi capaz de aumentar o índice cardíaco em 24,1% e de reduzir a resistência vascular sistêmica em 16%. Na segunda fase os pacientes foram seguidos por 5 dias consecutivos conforme randomização e apresentaram melhora hemodinâmica significativa somente nos primeiros dois dias. O maior aumento do índice cardíaco foi de 23,3% e a maior redução da resistência vascular sistêmica foi de 19,3% no grupo tratado com calor. A partir do terceiro dia não houve mais benefício da termoterapia. Da mesma forma, não verificamos diferença entre os níveis de BNP dosados entre o primeiro e quinto dias de seguimento entre os grupos. Conclusões: o calor como vasodilatador foi capaz de aumentar o índice cardíaco e diminuir a resistência vascular sistêmica nos primeiros dias de tratamento na ICD. Entretanto, não houve benefício adicional em sessões repetidas por cinco dias consecutivos ou melhora dos níveis de BNP. Os dados sugerem que a termoterapia pode vir a representar uma abordagem terapêutica adjuvante para o tratamento dos pacientes com ICD. No entanto, um ensaio clínico randomizado com número maior de pacientes é necessário para explorar sua potencial efetividade clínica / Background: adjuvant measures have been proposed for the treatment of heart failure patients, some non-pharmacological, such as the use of heat. Despite the positive results for clinically stable patients, there are no studies related to use thermal therapy in patients with decompensated heart failure (DHF) and in use of vasoactive drugs. Objectives: To evaluate the acute hemodynamic effects of heat applied through the thermal blanket in patients with refractory decompensated heart failure. It was established as outcomes the increase of cardiac index and decrease of systemic vascular resistance on the first day of follow-up. Secondary objective was to evaluate whether repeated sessions of heat for five consecutive days would promote or sustain the hemodynamic effects obtained acutely, and if it would reduce BNP levels during the follow-up. Methods: open label randomized clinical trial, with control group, in patients with DHF. The study was divided into two phases. In the first phase, patients were studied in a single day and the acute effects of heat were evaluated before and after intervention. In the second phase, the effects of heat were evaluated by daily sessions for five consecutive days. An infrared thermal blanket was used to heating the patients. Hemodynamic measurements were assessed through invasive Swan-Ganz catheter and noninvasively by the method of modelflow. The patients were receiving continuous intravenous inotropic therapy and were classified in the profile C according to Stevenson´s clinical and hemodynamic classification and were considered refractory after failure in the attempted of withdraw the vasoactive drugs. The study population was divided into 2 groups: group T (thermal therapy) and group C (control). Group T was submitted to vasodilation through the thermal blanket at 50 °C for 40 minutes in addition to drug treatment. Patients in group C maintained the drug treatment and the thermal blanket was positioned in the same way for 40 minutes, but turned off. Statistical analysis: The variables were analyzed by Fisher\'s exact test or likelihood ratio. Normality was assessed with Komogorov-Smirnov test. Quantitative variables were presented as mean and standard deviation. Means were evaluated using analysis of variance for repeated measures (ANOVA). When significant, contrasts were used to discriminate the differences between times. Measurements evaluated at a single time were compared with Student\'s t test. We used the Pearson correlation coefficient to analyze the correlation between the measurements. A p-value < 0.05 was considered statistically significant. Results: Between October 2007 and April 2013, 165 patients were evaluated for possible eligibility. Of these, 12 patients refused to participate in the study and 105 were excluded by the exclusion criteria. There were included 48 patients, however, 10 patients were excluded in the pre-randomization. Eight patients were initially evaluated and were submitted to heart sessions for security and validation of the method and 30 patients were randomized until the end of the study. In total, 38 patients were studied. There were no differences in the baseline characteristics between the study groups. In the first phase, 38 patients were analyzed pre and post-intervention. The thermal vasodilation was able to increase the cardiac index by 24.1% and to reduce the systemic vascular resistance by 16%. In the second phase, patients were followed up for 5 consecutive days according to randomization and showed significant hemodynamic improvement only in the first two days. The largest increase in cardiac index was 23.3 % and the greatest reduction in systemic vascular resistance was 19.3 % in the group treated with heat. From the third day there was no benefit of thermal therapy. Likewise, there was no difference in the levels of BNP measured in the first and fifth day of follow-up between groups. Conclusions: heat as a vasodilator was able to increase the cardiac index and lower the systemic vascular resistance in the first days of treatment in the DHF. However, there was no additional benefit in repeated sessions for five consecutive days or improvement in the BNP levels. The data suggest that thermal therapy may come to represent a therapeutic approach for the adjuvant treatment of patients with DHF. Nonetheless, a randomized clinical trial with a larger number of patients is needed to explore its potential clinical effectiveness
36

Reconhecimento de atividades suspeitas em ambiente externo via análise de vídeo infravermelho

Fernandes, Henrique Coelho 26 October 2011 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Surveillance has become, in the last years, something ubiquity in our society. Every day it is more notorious the presence of intelligent systems for surveillance in our everyday life. This is due to technological advances achieved in recent decades (storage and processing speed increasing, miniaturization of devices like biometric detectors and video cameras) as the constant feeling of insecurity experienced in several countries. Following the dark days of 9/11, security and surveillance became paramount. This work aims the study of techniques for the development of a surveillance system of an outdoor parking lot based on a stationary camera. Considering that in an outdoor parking lot it is very important that the surveillance is made both day and night, in this work we use an infrared camera to record images. An infrared camera allows to see objects of interest in the scene even at night. The images used for the experiments in this work were recorded by the student in Laval University campus (Canada) during an internship he held in the "Canada Research Chair in Multipolar Infrared Vision". A surveillance system based on video cameras is usually composed of three parts: (i) motion detection, (ii) tracking and (iii)event management. In this work, we use a dynamic background subtraction technique to detect motion (motion segmentation). This technique adapts to abrupt changes on the scene's illumination making the technique robust to this changes. Besides, we use ow analysis to restrict the segmentation process only to regions where we have motion in the scene. The object tracking technique used is based on a two phase cycle: prediction and correction. The events of interest which occur in the monitored area are modeled explicitly and then recognized and interpreted. The main goal of this project is to recognize suspicious events. Experimental results show that such techniques are suitable for a surveillance system for an outdoor parking lot based on a infrared stationary camera. / Vigilância se tornou, nos últimos anos, algo ubíquo em nossa sociedade. Cada dia que passa é mais notória a presença de sistemas inteligentes de vigilância em nosso dia-a-dia. Isso se deve tanto aos avanços tecnológicos alcançados nas últimas décadas (aumento da capacidade de processamento e armazenamento, miniaturização de dispositivos como detectores biométricos e câmeras de vídeo) como a constante sensação de insegurança vivida em vários países. Após os dias sombrios de 11/09, segurança e vigilância se tornaram algo primordial. Este trabalho visa o estudo de técnicas para o desenvolvimento de um sistema de vigilância para um estacionamento externo baseado em uma câmera estacionária. Tendo em vista que em um estacionamento externo é de suma importância que a vigilância seja feita tanto de dia quanto de noite, neste trabalho utilizamos uma câmera que captura imagens infravermelhas. Uma câmera infravermelha permite que enxerguemos objetos de interesse na cena até mesmo a noite. As imagens usadas nos experimentos realizados neste trabalho foram colhidas no campus da Universidade de Laval (Canadá) durante um estágio realizado no Canada Research Chair in Multipolar Infrared Vision. Um sistema de vigilância baseado em câmeras de vídeo geralmente possui três partes principais: (i) detecção de movimento, (ii) monitoramento e (iii) gerenciamento de eventos. Neste trabalho, utilizamos uma dinâmica técnica de subtração de plano de fundo para realizar a detecção de movimento (segmentação de movimento). Esta técnica se adapta às mudanças bruscas de iluminação na cena tornando o método de segmentação robusto a estas mudanças. Além disso, utilizamos análise de uxo de movimento para restringir a segmentação somente às regiões onde existem algum movimento na cena. A técnica de monitoramento de objetos em movimento usada neste trabalho é baseada em um ciclo de dois estágios: previsão e correção. Os eventos de interesse que ocorrem na área monitorada são modelados de forma explícita sendo então reconhecidos e interpretados. O foco principal deste trabalho é o reconhecimento de eventos suspeitos. Resultados experimentais obtidos mostram que tais técnicas são adequadas para um sistema de vigilância de um estacionamento externo baseado em uma câmera estacionária infravermelha. / Mestre em Ciência da Computação
37

Vasodilatação induzida pelo calor através de dispositivo portátil no leito na insuficiência cardíaca descompensada / Thermal vasodilation using a portable infrared thermal blanket in decompensated heart failure

Marcelo Villaça Lima 24 March 2014 (has links)
Fundamento: medidas adjuvantes têm sido propostas para o tratamento de pacientes com insuficiência cardíaca, algumas não farmacológicas, como o uso do calor. Apesar dos resultados positivos para pacientes clinicamente estáveis, não existem trabalhos relacionados ao tratamento com calor na fase descompensada da insuficiência cardíaca em pacientes em uso de drogas vasoativas. Objetivos: avaliar os efeitos hemodinâmicos agudos do calor aplicado através da manta térmica em pacientes com insuficiência cardíaca descompensada (ICD) refratária. Para isso foi estabelecido como desfechos o aumento do índice cardíaco e a redução da resistência vascular sistêmica no primeiro dia de seguimento. Como objetivo secundário, avaliar se sessões repetidas de calor por cinco dias consecutivos promoveria ou sustentaria os efeitos hemodinâmicos obtidos agudamente e, se reduziria os níveis de BNP ao longo do seguimento. Métodos: ensaio clínico randomizado aberto, prospectivo, com grupo controle em pacientes portadores de ICD. O estudo foi dividido em duas fases. Na primeira fase foram estudados pacientes em um único dia e foi avaliado o efeito agudo do calor antes e após a intervenção. Na segunda fase o calor foi avaliado através de sessões diárias por cinco dias consecutivos. Foi utilizada a manta térmica por radiação infravermelha para o aquecimento dos pacientes. As medidas hemodinâmicas foram avaliadas por método invasivo através do cateter de Swan-Ganz e de maneira não invasiva pelo método de modelflow. Os pacientes estavam em uso de inotrópico endovenoso contínuo, no perfil hemodinâmico C segundo a classificação clínico-hemodinâmica de Stevenson e foram considerados refratários após tentativa de retirada da droga vasoativa sem sucesso. A população do estudo foi dividida em 2 grupos: grupo T (termoterapia) e grupo C (controle). O grupo T foi submetido à vasodilatação térmica através da manta térmica na temperatura de 50°C por 40 minutos adicionalmente ao tratamento medicamentoso. Os pacientes do grupo C mantiveram o tratamento medicamentoso e a manta térmica foi posicionada da mesma maneira por 40 minutos, porém desligada. Análise estatística: as variáveis foram analisadas pelo teste exato de Fisher ou razão de verossimilhança. A normalidade foi avaliada com o teste de Komogorov-Smirnov. As variáveis quantitativas foram apresentadas por média e desvio padrão. As médias foram avaliadas com análise de variância para medidas repetidas (ANOVA). Quando significante, utilizou-se contrastes para discriminar as diferenças entre os momentos. As medidas avaliadas em um único momento foram comparadas com teste t-Student. Foi utilizado o coeficiente de correlação de Pearson para a análise da correlação entre as medidas. Foram considerados estatisticamente significantes os valores de p < 0,05. Resultados: entre outubro de 2007 e abril de 2013, 165 pacientes foram avaliados para possível elegibilidade. Destes, 12 pacientes recusaram participar do estudo e 105 foram excluídos pelos critérios de exclusão. Foram incluídos 48 pacientes, entretanto, 10 pacientes foram excluídos prérandomização. Foram avaliados inicialmente 8 pacientes que foram submetidos a sessões de calor para segurança e validação do método e 30 pacientes foram randomizados até o término do estudo. No total, 38 pacientes foram estudados. Não houve diferença nas características basais entre os grupos estudados. Na primeira fase foram avaliados 38 pacientes, pré e pós-intervenção. A vasodilatação térmica foi capaz de aumentar o índice cardíaco em 24,1% e de reduzir a resistência vascular sistêmica em 16%. Na segunda fase os pacientes foram seguidos por 5 dias consecutivos conforme randomização e apresentaram melhora hemodinâmica significativa somente nos primeiros dois dias. O maior aumento do índice cardíaco foi de 23,3% e a maior redução da resistência vascular sistêmica foi de 19,3% no grupo tratado com calor. A partir do terceiro dia não houve mais benefício da termoterapia. Da mesma forma, não verificamos diferença entre os níveis de BNP dosados entre o primeiro e quinto dias de seguimento entre os grupos. Conclusões: o calor como vasodilatador foi capaz de aumentar o índice cardíaco e diminuir a resistência vascular sistêmica nos primeiros dias de tratamento na ICD. Entretanto, não houve benefício adicional em sessões repetidas por cinco dias consecutivos ou melhora dos níveis de BNP. Os dados sugerem que a termoterapia pode vir a representar uma abordagem terapêutica adjuvante para o tratamento dos pacientes com ICD. No entanto, um ensaio clínico randomizado com número maior de pacientes é necessário para explorar sua potencial efetividade clínica / Background: adjuvant measures have been proposed for the treatment of heart failure patients, some non-pharmacological, such as the use of heat. Despite the positive results for clinically stable patients, there are no studies related to use thermal therapy in patients with decompensated heart failure (DHF) and in use of vasoactive drugs. Objectives: To evaluate the acute hemodynamic effects of heat applied through the thermal blanket in patients with refractory decompensated heart failure. It was established as outcomes the increase of cardiac index and decrease of systemic vascular resistance on the first day of follow-up. Secondary objective was to evaluate whether repeated sessions of heat for five consecutive days would promote or sustain the hemodynamic effects obtained acutely, and if it would reduce BNP levels during the follow-up. Methods: open label randomized clinical trial, with control group, in patients with DHF. The study was divided into two phases. In the first phase, patients were studied in a single day and the acute effects of heat were evaluated before and after intervention. In the second phase, the effects of heat were evaluated by daily sessions for five consecutive days. An infrared thermal blanket was used to heating the patients. Hemodynamic measurements were assessed through invasive Swan-Ganz catheter and noninvasively by the method of modelflow. The patients were receiving continuous intravenous inotropic therapy and were classified in the profile C according to Stevenson´s clinical and hemodynamic classification and were considered refractory after failure in the attempted of withdraw the vasoactive drugs. The study population was divided into 2 groups: group T (thermal therapy) and group C (control). Group T was submitted to vasodilation through the thermal blanket at 50 °C for 40 minutes in addition to drug treatment. Patients in group C maintained the drug treatment and the thermal blanket was positioned in the same way for 40 minutes, but turned off. Statistical analysis: The variables were analyzed by Fisher\'s exact test or likelihood ratio. Normality was assessed with Komogorov-Smirnov test. Quantitative variables were presented as mean and standard deviation. Means were evaluated using analysis of variance for repeated measures (ANOVA). When significant, contrasts were used to discriminate the differences between times. Measurements evaluated at a single time were compared with Student\'s t test. We used the Pearson correlation coefficient to analyze the correlation between the measurements. A p-value < 0.05 was considered statistically significant. Results: Between October 2007 and April 2013, 165 patients were evaluated for possible eligibility. Of these, 12 patients refused to participate in the study and 105 were excluded by the exclusion criteria. There were included 48 patients, however, 10 patients were excluded in the pre-randomization. Eight patients were initially evaluated and were submitted to heart sessions for security and validation of the method and 30 patients were randomized until the end of the study. In total, 38 patients were studied. There were no differences in the baseline characteristics between the study groups. In the first phase, 38 patients were analyzed pre and post-intervention. The thermal vasodilation was able to increase the cardiac index by 24.1% and to reduce the systemic vascular resistance by 16%. In the second phase, patients were followed up for 5 consecutive days according to randomization and showed significant hemodynamic improvement only in the first two days. The largest increase in cardiac index was 23.3 % and the greatest reduction in systemic vascular resistance was 19.3 % in the group treated with heat. From the third day there was no benefit of thermal therapy. Likewise, there was no difference in the levels of BNP measured in the first and fifth day of follow-up between groups. Conclusions: heat as a vasodilator was able to increase the cardiac index and lower the systemic vascular resistance in the first days of treatment in the DHF. However, there was no additional benefit in repeated sessions for five consecutive days or improvement in the BNP levels. The data suggest that thermal therapy may come to represent a therapeutic approach for the adjuvant treatment of patients with DHF. Nonetheless, a randomized clinical trial with a larger number of patients is needed to explore its potential clinical effectiveness
38

Relação entre a oferta e a utilização muscular periférica de oxigênio na transição do exercício leve para o intenso em pacientes com insuficiência cardíaca / Peripheral muscle oxygen delivery-to-utilization mismatch in the transition from mild to heavy-intensity exercise in patients with CHF

Sperandio, Priscila Cristina de Abreu [UNIFESP] 24 November 2010 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:50:43Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-11-24. Added 1 bitstream(s) on 2015-08-11T03:26:10Z : No. of bitstreams: 1 Publico-12685a.pdf: 1258050 bytes, checksum: 53b17db1fdfbd3e4583d4358e7515aed (MD5). Added 1 bitstream(s) on 2015-08-11T03:26:10Z : No. of bitstreams: 2 Publico-12685a.pdf: 1258050 bytes, checksum: 53b17db1fdfbd3e4583d4358e7515aed (MD5) Publico-12685b.pdf: 2009901 bytes, checksum: 92f9b67aa48fc3b5890595ab949a78a4 (MD5). Added 1 bitstream(s) on 2015-08-11T03:26:10Z : No. of bitstreams: 3 Publico-12685a.pdf: 1258050 bytes, checksum: 53b17db1fdfbd3e4583d4358e7515aed (MD5) Publico-12685b.pdf: 2009901 bytes, checksum: 92f9b67aa48fc3b5890595ab949a78a4 (MD5) Publico-12685c.pdf: 2013198 bytes, checksum: 64df6a7e1d8d760785004ef7cb8107b9 (MD5) / Na insuficiencia cardiaca (IC) o comprometimento do fluxo sanguineo muscular na transicao do exercicio leve para o intenso pode reduzir temporariamente a pressao microvascular de O2 e diminuir a oferta de O2 do capilar para a mitocondria. No entanto, os avancos no tratamento medicamentoso da IC (por exemplo, os inibidores da enzima conversora de angiotensina e ƒÀ-bloqueadores de terceira geracao) poderiam ter melhorado a oferta microvascular de O2 a um ponto em que a lentidao da maquinaria metabolica intramuscular passaria a ser o fator limitante da resposta cinetica do consumo de oxigenio ( O2). O objetivo do presente estudo foi investigar a relacao dinamica entre oferta e utilizacao microvascular de O2 na transicao do exercicio leve (sem carga) para o intenso, em portadores de IC com tratamento otimizado e nao treinados, comparado a um grupo controle de individuos saudaveis. Foram incluidos 10 pacientes com IC com tratamento clinico otimizado (fracao de ejecao = 29 } 8%) e 11 controles pareados por idade. Avaliou-se as respostas cineticas da captacao pulmonar de O2 ( O2p), da extracao tissular de O2 no musculo vasto lateral, como estimada pela variacao na concentracao relativa de deoxihemoglobina + mioglobina (~ƒ¢[deoxi-Hb+Mb]), mensurada pelo metodo de espectroscopia de raios quasi-infravermelhos (NIRS) e do debito cardiaco (DC), durante exercicio de alta intensidade ate o limite de tolerancia (Tlim). A cinetica da O2p e do DC foram mais lentas nos pacientes com IC em comparacao aos controles e correlacionaram-se significativamente com menores valores de Tlim (P = 0,05). A cinetica total da ƒ¢[deoxi-Hb+Mb] foi mais rapida nos pacientes do que nos controles (tempo medio de resposta (MRT) = 15,9 } 2,0 s vs. 19,0 } 2,9 s; P = 0,05), com uma resposta de "overshoot" presente apenas nos pacientes (7/10). Alem disso, a razao t O2p/MRT-ƒ¢[deoxi-Hb+Mb] foi maior nos pacientes (4,69 } 1,42 s vs. 2,25 } 0,77 s; P < 0,05) e correlacionou-se com a cinetica do DC e o Tlim (R = 0,89 e 0,78, respectivamente; P = 0,01). Conclui-se que apesar dos avancos no tratamento medicamentoso da IC, os disturbios nos ajustes circulatorios "centrais" e "perifericos" continuam a desempenhar um papel proeminente na limitacao da cinetica da O2p e tolerancia a exercicio de alta intensidade em pacientes nao treinados com IC. / Impaired muscle blood flow at the onset of heavy-intensity exercise may transiently reduce microvascular O2 pressure and decrease the rate of O2 transfer from capillary to mitochondria in chronic heart failure (CHF). However, advances in the pharmacological treatment of CHF (e.g., angiotensin-converting enzyme inhibitors and third generation of â-blockers) may have improved microvascular O2 delivery to an extent that intramyocyte metabolic inertia might become the main locus of limitation of O2 uptake ( O2) kinetics. We included 10 optimally treated sedentary patients (ejection fraction = 29 ± 8%) and 11 age-matched controls. We assessed the rate of change of pulmonary O2 ( O2p), tissue O2 extraction in the vastus lateralis estimated by concentration of deoxy-hemoglobin+myoglobin (~Ä[deoxy-Hb+Mb]) measured by near-infrared spectroscopy (NIRS), and cardiac output ( T) during highintensity exercise performed to the limit of tolerance (Tlim). Sluggish O2p and T kinetics in patients were significantly related to lower Tlim values (P = 0.05). The dynamics of Ä[deoxy-Hb+Mb] were faster in patients than controls (mean response time (MRT) = 15.9 ± 2.0 s vs. 19.0 ± 2.9 s; P = 0.05) with a subsequent response “overshoot” being found only in patients (7/10). Moreover, t O2p/MRT-Ä[deoxy- Hb+Mb] ratio was greater in patients (4.69 ± 1.42 s vs. 2.25 ± 0.77 s; P = 0.05) and related to T kinetics and Tlim (R = 0.89 and 0.78, respectively; P = 0.01). We conclude that despite the advances in the pharmacological treatment of CHF, disturbances in “central” and “peripheral” circulatory adjustments still play a prominent role in limiting O2p kinetics and tolerance to heavy-intensity exercise in nontrained patients. / TEDE / BV UNIFESP: Teses e dissertações

Page generated in 0.0479 seconds