• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 262
  • 12
  • 11
  • 10
  • 10
  • 10
  • 10
  • 5
  • 1
  • Tagged with
  • 283
  • 161
  • 103
  • 77
  • 60
  • 44
  • 42
  • 38
  • 36
  • 30
  • 27
  • 27
  • 27
  • 24
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Análise da integridade estrutural em dutos de condução de petróleo e gás com incidência de mossas

SOUSA, José Manoel de 24 February 2017 (has links)
Submitted by Pedro Barros (pedro.silvabarros@ufpe.br) on 2018-07-31T19:47:08Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE José Manoel de Sousa.pdf: 5234006 bytes, checksum: d0c67b3a526933cbc2e8574c3e43b9d3 (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-08-01T21:51:25Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE José Manoel de Sousa.pdf: 5234006 bytes, checksum: d0c67b3a526933cbc2e8574c3e43b9d3 (MD5) / Made available in DSpace on 2018-08-01T21:51:25Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE José Manoel de Sousa.pdf: 5234006 bytes, checksum: d0c67b3a526933cbc2e8574c3e43b9d3 (MD5) Previous issue date: 2017-02-24 / Este estudo desenvolve-se no eixo de integridade estrutural de dutos por onde escoam petróleo e derivados. Tem-se como vetor a normatização internacional vigente. Quanto aos critérios de aceitação de dutos indentados (mossas). Uma parcela das normas vigentes toma como critério de rejeição, a profundidade da mossa, ou uma relação desta com o diâmetro externo da tubulação. Embora existam relatos de acidentes que ocorreram em dutos, cujos critérios estavam dentro dos parâmetros destas normas, razão pela qual tenta-se através deste trabalho, alternativas de pesquisa que forneçam outros meios, quando possível, além dos estabelecidos nestes regramentos internacionais. Este estudo compreende parte experimental, onde elabora-se corpo de prova devidamente normatizado, após esta etapa executa-se o processo de indentação, que consiste de criação de mossa. Em seguida, de posse do corpo de prova indentado (mossa), utilizou-se o laboratório da General Eletric, onde procedeu-se a criação da geometria deformada real em 3D. Para tanto foi utilizado o único tomógrafo industrial existente na América Latina. Após esta etapa, passa-se ao trabalho de refinamento do modelo através de software específicos, pois o modelo inicial oriundo da GE contém 1.399.466 faces, e 699.724 vértices. Para definir as propriedades do aço API 5L X80 foram realizados três ensaios de tração com corpos de provas normatizados, conforme ASTM E8/E8M-09 (2010), recomendação da API 5L. Foi realizada a simulação de teste de pressão no espécime sendo submetido este corpo a uma pressão de 50 MPa, conforme API 5L, obteve-se uma tensão de Mises de 370 MPa. Outra simulação realizada foi com um duto de 24 Polegadas e meia de espessura de parede, foram executados seis casos com mossas de profundidade diferentes, após cada teste de indentação foi utilizado o APDL do ANSYS® para recuperar a geometria deformada e iniciar nova simulação de pressurização de cada caso, as pressões impostas foram regidas conforme dois casos: O primeiro foi submetida a pressão conforme a norma CFR 192, que versa sobre a MAOP, o segundo caso de pressão foi baseado conforme a norma API 5L que define que para este espécime de 24” e material X80, a pressão máxima de teste é de 20,7 MPa. Tendo apenas a mossa do caso 6 não sido aprovada. / This study is developed in the axis of structural integrity of pipelines through which oil and derivatives flow. The current international standardization is a vector. Concerning the acceptance criteria for indented pipelines (dents). A part of the current norms take as criterion of rejection, the depth of the ditch, or a relation of this with the external diameter of the pipe. Although there are reports of accidents that occurred in pipelines, whose criteria were within the parameters of these norms, which is why we try through this work research alternatives that provide other means, when possible, in addition to those established in these international regulations. This study comprises an experimental part, where a properly normalized proof body is elaborated, after this stage the indentation process is carried out, which consists of creation of the dent. Then, with the indented specimen (dent), the General Electric laboratory was used, where the real deformed geometry was created in 3D. For this purpose, the only industrial tomographer in Latin America was used. After this step, we proceed to the work of model refinement through specific software, since the initial model from GE contains 1,399,466 faces, and 699,724 vertex. In order to define the properties of API 5L X80 steel three tensile tests were carried out with normalized test bodies, according to ASTM E8 / E8M-09 (2010), API 5L recommendation. The pressure test simulation was performed on the specimen and the body was subjected to a pressure of 50 MPa, according to API 5L, a Mises tension of 370 MPa was obtained. Another simulation was performed with a duct of 24 Inches and a half of wall thickness, six cases with different depth dips were executed, after each indentation test the ANSYS APDL was used to recover the deformed geometry and to initiate new simulation of pressurizing of In each case, the imposed pressures were governed according to two cases: The first one was subjected to pressure according to CFR 192, which deals with MAOP, the second pressure case was based on the API 5L standard that defines that for this specimen of 24 "And X80 material, the maximum test pressure is 20.7 MPa. Having just the dent of case 6 not been approved.
42

O entorno de monumentos e a conservação urbana: uma contribuição para a integridade

Leal, Thalianne de Andrade 30 June 2011 (has links)
Submitted by Sandra Maria Neri Santiago (sandra.neri@ufpe.br) on 2016-04-14T14:13:25Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) DISSERTAÇÃO - Thalianne de Andrade Leal.pdf: 2510019 bytes, checksum: 2da7c82c8d63d8018e80a8e30f841238 (MD5) / Made available in DSpace on 2016-04-14T14:13:25Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) DISSERTAÇÃO - Thalianne de Andrade Leal.pdf: 2510019 bytes, checksum: 2da7c82c8d63d8018e80a8e30f841238 (MD5) Previous issue date: 2011-06-30 / O rápido e intenso desenvolvimento urbano atual vem impondo ao campo da Conservação dos monumentos novas inquietações. A tentativa de conciliação entre arquitetura contemporânea, a integridade dos monumentos e o desenvolvimento urbano está presente na pauta de especialistas preocupados com o impacto de novas estruturas sobre as heranças urbanas. Aos bens inscritos ou tombados pelos órgãos da preservação já são garantidas medidas de salvaguarda, com isso a preocupação foca-se em seu entorno. Apesar da recorrente indicação de que o entorno é parte importante para a compreensão das informações do bem ao contribuir com a manutenção da sua integridade, poucas medidas o definiram conceitualmente e não chegaram a efetivar uma metodologia que possibilitasse sua delimitação. A partir da discussão dos conceitos e de experiências de delimitação do entorno, foi adotada neste trabalho a investigação sobre as dificuldades que tardam a sua efetividade como ferramenta do campo da Conservação. Optou-se por focar no entorno de bens arquitetônicos situados em território urbano, opção esta que ligou à discussão ao território das cidades, aos seus atores, instrumentos normativos e interesses. Sendo o ambiente urbano alvo de constantes mudanças e permanências, a efetividade do entorno parte do acompanhamento das tendências para alteração da composição morfológica e dos seus atributos ao longo do tempo, os quais têm interferência sobre a continuidade na transmissão das informações dos bens. Interesses diversos sobrepõem-se nas cidades, e muitos deles dificultam as ações da Conservação. São destacadas também as dificuldades de integração entre instituições e instrumentos para a utilização da ferramenta. Compreendidas as dificuldades e sanadas as lacunas, o entorno pode efetivar-se como uma ferramenta auxiliar contra as investidas de modificações na proximidade de monumentos e contribuir para a manutenção da sua integridade. / Actually, the rapid and intense urban development has imposing on the field of monuments conservation new concerns. The attempt to reconcile contemporary architecture, the monuments integrity and urban development is present on the staff of specialists concerned with the impact of new structures on urban heritage. To property protected are warranted preservation measures, thus the concern focuses on his buffer zones. Despite the applicant's statement that the environment is an important part to understand the property information to contribute to the maintenance of its integrity, few measures have defined conceptually and failed to effect a methodology that would enable its boundaries. From the discussion of concepts and experiences of defining the buffer zone, was adopted in this research work on the difficulties that are delaying its effectiveness as a tool in the field of Conservation. We chose to focus on the buffer zone architectural property located in urban territory, that option is called to discuss the territory of the cities, its actors, instruments and regulatory interests. As the urban environment subject to constant change and permanence, the effectiveness of the buffer zone focus of the monitoring of trends and morphological change in the composition of its attributes over time, which have interference on the continuous transmission of property information’s. Diverse interests overlap in the cities, and many hinder the Conservation actions. Are also highlighted the difficulties of integration between institutions and instruments for the use of the tool. Understood the difficulties and shortcomings remedied, the buffer zone can manifest itself as an auxiliary tool against the onslaught of changes in the monuments surroundings and contribute to the maintenance of its integrity
43

Influência da geometria da ferramenta e das condições de usinagem nas características de superfícies torneadas da liga 625 de Ni / Tool geometry and machining conditions influence in turned surfaces on features off 625 Ni alloy

Loureiro, Daniel, 1986- 28 August 2018 (has links)
Orientador: Anselmo Eduardo Diniz / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-28T12:31:16Z (GMT). No. of bitstreams: 1 Loureiro_Daniel_M.pdf: 3345826 bytes, checksum: a140e145cbae9ae1a5f3f14eaee94c0f (MD5) Previous issue date: 2015 / Resumo: As ligas de níquel são utilizadas em diversos setores industriais sempre que há necessidade de se associar elevada resistência mecânica com resistência à corrosão, ao desgaste e à oxidação. No entanto, as ligas de níquel apresentam baixa usinabilidade, implicando em processos relativamente ineficientes nos quais o desgaste da ferramenta e a integridade superficial são os principais fatores limitantes. A baixa usinabilidade destas ligas está relacionada com as suas características inerentes, tais como: alta dureza e resistência mecânica a quente, altas tensões de cisalhamento durante o processo de corte, alta taxa de encruamento, presença de carbonetos abrasivos na matriz, baixa condutividade térmica e soldagem da peça e da aresta de corte. Dentre as ligas de níquel, uma que apresenta propriedades desejadas para a indústria de exploração de petróleo é a liga 625. O objetivo do presente trabalho é a verificação da integridade da superfície usinada da liga 625, pela caracterização através da rugosidade, microestrutura, microdureza Vickers da superfície e da subsuperfície e da tensão residual de oito diferentes superfícies torneadas com diferentes geometrias da ferramenta (positiva e negativa) e diferentes condições de usinagem. Neste trabalho foram avaliados os danos que o torneamento em condições de acabamento proporciona à superfície usinada e que podem resultar em variação da resistência à corrosão e à fadiga. Dentre os principais resultados destaca-se aquele que aponta que as superfícies torneadas com geometria positiva da ferramenta produziram tensões compressivas na superfície, enquanto aquelas torneadas com ferramentas negativas produziram tensões trativas na superfície / Abstract: The nickel alloys are used in many industrial sectors where there is a need to associate high mechanical strength with resistance to corrosion, wear and oxidation. However, nickel alloys have poor machinability, resulting in relatively inefficient process wherein tool wear and surface integrity are the limiting primary factors. The low machinability of these alloys is related to their inherent characteristics, such as hot hardness and mechanical resistance, high shear rates during the cutting process, high work hardening rate, presence of abrasive carbides in the matrix, low thermal conductivity and welding the workpiece and cutting edge. Among the nickel alloys, one that has desired properties to the oil exploration industry is the alloy 625. The aim of this work is the check of the surface integrity through the characterization by roughness, microstructure, microhardness of the surface and sub- surface and residual stress, of eight turned different surfaces with different geometries tool (positive and negative) and machining conditions. This study evaluated the damage that finish conditions provides to the machined surface and witch can result in variations of resistance to corrosion and fatigue. Among the main results stands out the one who points out that turned surfaces with positive tool geometry produced compressive residual stresses on the surface, while those with negative turned tools produced tensile residual stresses on the surface / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica
44

Seleção de indicadores ecológicos para a avaliação de planos de restauração de áreas degradadas / Selection of indicators for ecological assessment of plans restoration of degraded areas

Fonseca, Vitor Hugo de Campos 16 June 2012 (has links)
Made available in DSpace on 2016-06-02T19:26:19Z (GMT). No. of bitstreams: 1 FONSECA_Vitor_2011.pdf: 1402147 bytes, checksum: 68adc13f57d441da94e1f7a4fe5bc04d (MD5) Previous issue date: 2012-06-16 / Ecological indicators are useful tools for forest monitoring. It is known that most restoration projects are doomed to failure due to factors of multiple spheres, and lead to a succession challenge course desirable. The practical relevance of the concept of ecological integrity objectives directed this study that, in general seeks to define practical indicators that can express the conditions of the areas restored in the early stages of restoration (up to 5 years). The indicators were rated from 0 to 3, according to criteria such as ease of measurement, degree of variation of response, ability to predict changes in the system, and weights of 1 to 3, given the degree of importance of each attribute of the indicators . The product of the note by the weight of each indicator expressed a measure of its efficiency (EF). In relation to indicators of composition, structure and function in each area, the AE2 was the one that appeared in better health. In relation to indicators of composition, structure and function of the area Itu (AE2) which was presented in a better position when compared to AE1. Among the indicators of composition, richness, diversity (H ') and the presence of exotic species were the most effective attributes, in relation to the structure, attributes were more effective tree density, the average annual increment of the variables and the dendrometric the indicator function, land cover, competition and sanity were more efficient in detecting changes and changes in areas so fast, convenient and understandable. / Indicadores ecológicos são ferramentas úteis para o monitoramento florestal. Sabe-se que a maioria dos projetos de restauração são fadados ao insucesso devido a fatores de múltiplas esferas, sendo um desafio conduzir a sucessão a rumos desejáveis. A relevância prática do conceito de integridade ecológica direcionou os objetivos deste estudo que, de forma geral busca definir indicadores práticos que possam exprimir as condições das áreas restauradas em fase inicial de restauração (até 5 anos). Os indicadores receberam notas de 0 a 3, de acordo com critérios, tais como facilidade de mensuração, grau de variação da resposta, capacidade de prever alterações no sistema, e pesos de 1 a 3, devido ao grau de importância de cada atributo dos indicadores. O produto da nota pelo peso de cada indicador exprimiu a medida de sua eficiência (EF). Em relação aos indicadores de composição, estrutura e função em cada área, a AE2 foi a que se apresentou em melhores condições de integridade. Em relação aos indicadores de composição, estrutura e função a área de Itu (AE2) foi a que se apresentou em melhores condições quando comparada a AE1. Dentre os indicadores de composição, a riqueza, a diversidade (H´) e a presença de espécies exóticas foram os atributos mais eficientes; em relação à estrutura, os atributos mais eficientes foram a densidade de arbóreas, o incremento médio anual das variáveis dendrométricas e quanto ao indicador de função, a cobertura do solo, a competição e a sanidade foram mais eficientes em detectar mudanças e alterações nas áreas de modo rápido, prático e compreensível.
45

[en] CORROSION FAILURE MANAGEMENT IN PIPELINE / [pt] GERENCIAMENTO DE FALHAS POR CORROSÃO EM DUTOS

ANNE AGUIAR DE ARAUJO 14 November 2012 (has links)
[pt] Esta dissertação visa apresentar e comparar metodologias utilizadas para estimar a taxa de corrosão a partir dos resultados obtidos em inspeção por pig instrumentado tendo em vista que este método de avaliação de integridade é um procedimento empregado por operadores de duto. Com esta finalidade foram analisadas e comparadas as metodologias mais adequadas para o cálculo da taxa de corrosão: Estimativa da Taxa de Corrosão baseada no Princípio de Atividade Local, Estimativa da Taxa de Corrosão baseada no Cálculo do Parâmetro (a), Estimativa da Taxa de Corrosão a partir do Intervalo de Confiança para a Média e Estimativa da Taxa de Corrosão a partir da Distribuição de Valor Extremo. Para cada um destes métodos foram empregados dados simulados e dados de inspeções de um duto existente, utilizando ou não o mapeamento de anomalias por tabela, a fim de conhecer e avaliar suas vantagens e limitações. Os resultados destas comparações mostraram que apenas no caso em que a taxa de corrosão é estimada partir do intervalo de confiança para a média, a correspondência entre as anomalias (mapeamento) registradas nas inspeções ILI é obrigatória. As demais metodologias podem ser aplicadas ao conjunto de anomalias mapeadas ou a todas perdas de metal informadas no relatório de inspeção ILI. Foi verificado também que os valores estimados para a taxa de corrosão quando é realizado o mapeamento das anomalias diferem das taxas de corrosão calculadas quando a comparação dos dados entre as inspeções não é efetuada. Embora tenha-se notado esta diferença foi observado que existe uma equivalência quando comparadas as taxas de corrosão de cada grupo. Ou seja, verifica-se uma correspondência entre os valores estimados por cada metodologia ao comparar apenas os resultados das anomalias mapeadas. O mesmo ocorre quando é efetuada a comparação entre valores da taxa de corrosão obtidos apenas pelos métodos em que o mapeamento das perdas de metal não foi realizado. Adicionalmente foi efetuada a comparação entre as principais normas e publicações de gerenciamento de integridade de dutos, como o ASME B31.8S, API 1160 e Muhlbauer. / [en] This work aims to present and compare methodologies used to estimate the corrosion rate from ILI inspection results once this integrity assessment is a procedure employed by pipeline operators. With this purpose the most appropriate methodologies for calculating the corrosion rate were analyzed and compared: Corrosion Rate Estimation based on the Principle of Local Corrosion Activity, Corrosion Rate Estimation based on the Parameter (a), Corrosion Rate Estimation from the Confidence Interval for Mean and Corrosion Rate Estimation from the Extreme Value Distribution. For each of these methods were employed simulated data and actual ILI inspection data, applying or not anomalies matching by table to identify and evaluate their advantages and limitations. The comparison has shown that the matching of the features is required only when the corrosion rate is estimated from the confidence interval methodology. The other methods can be applied to matched metal loss or all anomalies registered in ILI reported. Furthermore, it was observed that the estimated corrosion rate from the anomalies matching differ of calculated corrosion rate when matching of metal loss between ILI inspections is not done. Although this difference has been identified, it was observed an equivalence when the corrosion rates of each group were compared. In other words, there is a correspondence between the values estimated by each corrosion rate methodology when is used only the sample which represents the matched metal loss.The same occurs when the comparison is carried out between the corrosion rate values obtained only by methods where the defect mapping was not done.Moreover, a comparison between the main codes and publications for pipeline integrity management, as B31.8S ASME, API 1160 and Muhlbauer was done.
46

Detecção de dano estrutural baseada na técnica da impedância eletromecânica em ambientes ruidosos /

Campeiro, Leandro Melo. January 2018 (has links)
Orientador: Fabricio Guimarães Baptista / Banca: Luiz Gonçalves Junior / Banca: Mário Anderson de Oliveira / Resumo: A técnica da impedância eletromecânica (E/M) tem sido amplamente estudada nas últimas décadas como um método não destrutivo para detectar danos estruturais em aplicações de monitoramento de integridade estrutural (SHM - structural health monitoring) usando transdutores piezelétricos de baixo custo. Esses transdutores operam simultaneamente como sensor e atuador e são fixados à estrutura monitorada utilizando um adesivo a base de cianoacrilato. Embora muitos estudos tenham relatado a eficácia desse método de detecção, inúmeros problemas práticos têm sido reportados, como os efeitos de ruído e vibração, que precisam ser considerados para permitir o uso eficaz desse método em aplicações reais. Portanto, esta dissertação de mestrado apresenta uma análise experimental dos efeitos do ruído e das vibrações na detecção de danos estruturais em sistemas de SHM baseados na técnica da impedância eletromecânica. Os experimentos foram realizados em uma barra de alumínio usando dois diafragmas piezelétricos, sendo que um deles foi usado para obter as assinaturas de impedância elétrica e o outro foi usado como atuador para introduzir ruído e vibração controlada. Para a simulação de dano foi utilizada uma pequena massa metálica fixada na estrutura com uso de adesivo a base de cianoacrilato. Os efeitos do ruído e da vibração sobre as assinaturas de impedância foram avaliados por meio do cálculo da função de coerência e de índices básicos de dano. Os resultados indicam que a vibração e o ruído ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The electromechanical impedance (EMI) technique has been extensively studied in recent decades as a non-destructive method for detecting structural damage in structural health monitoring (SHM) applications using low-cost piezoelectric transducers. These transducers operate simultaneously as actuator and sensor and they are fixed to the structure using cyanoacrylate-based glue. Although many studies have reported the effectiveness of this detection method, a lot of practical problems shown up, such as the noise effects and vibration, that need to be addressed to enable this method's effective use in real applications. Therefore, this master's thesis presents an experimental analysis of noise and vibration effects on the structural damage detection in impedance-based SHM systems. The experiments were performed on an aluminum bar using two piezoelectric diaphragms, where one was used to measure the electrical impedance signatures and the other was used as an actuator to introduce noise and controlled vibration. To simulate damage, a small metal mass was fixed to the structure using cyanoacrylate glue. The effects of noise and vibration on the impedance signatures were evaluated by computing the coherence function and basic damage indices. The results indicate that vibration and noise significantly affect the threshold of the lowest detectable damage, which can be compensated by increasing the excitation signal of the piezoelectric transducer that measure the electrical impedance... (Complete abstract click electronic access below) / Mestre
47

[en] STRUCTURAL INTEGRITY OF PLAIN DENTS IN PIPELINES / [pt] ANÁLISE DE INTEGRIDADE ESTRUTURAL DE DUTOS COM MOSSAS SIMPLES

MAIRA AMANDA VARGAS AVILA 26 December 2007 (has links)
[pt] O presente trabalho analisa o impacto de uma mossa simples transversal na integridade estrutural de espécimes tubulares de paredes finas com dimensões e características semelhantes aos dutos usados para transporte de óleo e gás. O estudo da mossa simples envolveu as etapas de criação, recuperação elástica e avaliação da sua resistência estática e cíclica. A abordagem do problema fundamentou-se na análise de dados experimentais e na modelagem numérica por elementos finitos. Na análise por elementos finitos foram consideradas: não linearidade por contato, plasticidade, grandes deslocamentos e grandes deformações. Adicionalmente, foram feitas comparações entre os resultados e os procedimentos usados na indústria, de modo a avaliar criticamente eventuais diferenças e semelhanças entre estes. Como resultado, a avaliação da ruptura estática permitiu verificar a pouca influência de mossas, com a geometria estudada, na resistência à ruptura. Entretanto, os códigos de projeto estudados não aceitam mossas com profundidades e deformações menores que as estudadas. A avaliação de resistência cíclica permitiu verificar a influência deste tipo de dano na vida à fadiga. No final foi elaborada uma rotina simples, baseada em fundamentos teóricos, que permite quantificar a vida à fadiga de mossas, com características similares, a partir do seu fator de concentração de tensão. / [en] This work analyzes the impact of transverse plain dents in the structural integrity of thin-thickness pipe specimens with similar dimensions and properties than typical pipelines. The dent analyzes included the following topics: creation, burst and fatigue evaluation and elastic recuperation. The problem was based in the study of experimental data and numerical modeling by finite elements. The numerical modeling considered: non linearity by contact, plasticity, large displacement and large strain. Finally, comparisons were made between the results and the typical industry procedures, in order to identify eventual differences and similarities. The burst evaluation indicated the low influence of the studied plain dents in the burst resistance. Otherwise, the project standards do not accept dents with the depth and strain levels like those studied. The cyclic analyze verified the influence of this type of damage in the fatigue life. At the end of this study, a simple procedure was developed based in theoric fundamentals to quantify the fatigue life of plain dents, with similar characteristics studied above, using their intensity stress factor.
48

Ação do ácido indol-3-acético sobre Staphylococcus aureus / Action of acid indole-3-acetic acido on Staphylococcus aureus

Vaz, Andréia Cristina Nakashima 02 March 2012 (has links)
O objetivo foi avaliar a ação do ácido indol-3-acético (AIA) na ausência e presença da peroxidase de raiz forte (HRP) sobre a viabilidade de cepas certificadas de Staphylococcus aureus ATCC 6538 (produtora de biofilme), ATCC 14458 (portadora do gene seb), ATCC 43300 (portadora do gene mecA) e ATCC 29213 (controle). Foi determinada a concentração inibitória mínima (CIM) e, após, escolheu-se uma concentração subinitória para avaliar a capacidade de formação de biofilme, atividade de enzimas antioxidantes, integridade de DNA, integridade de membrana para todas as cepas e avaliação da expressão do gene seb da cepa ATCC 14458. A CIM observada foi de 40 mM de AIA para cepa ATCC 6538, 60 mM para ATCC 43300,50 mM para ATCC 14458 e ATCC 29213. No entanto, houve diferença significativa (P<0,05), na presença de HRP, somente para as cepas ATCC 14458 e 43300. A concentração subinibitória de AIA utilizada foi de 30 mM para ATCC 6538 e ATCC 14458, e de 40 mM para ATCC 43300 e ATCC 29213.mM. A capacidade de formação de biofilme pelo S. aureus(biofilme positivo) não foi alterada pela presença de AIA ou AIA/HRP. A atividade específica de catalase e superóxido dismutase foi aumentada pela ação de AIA/HRP (P<0,05) para todas as cepas, porém, não houve diferença (P>0,05) entre AIA e AIA/HRP. O DNA manteve-se íntegro, porém, houve diminuição na integridade de membrana (P<0,05) para todas as cepas cultivadas na concentração subinibitória de AIA, sendo este efeito potencializado na presença de HRP somente para ATCC 43300. Houve redução na expressão do gene seb da cepa ATCC 14458 (P<0,05). Conclui-se que o AIA, associado à HRP apresenta efeito bacteriostático em cepas de Staphylococcus aureus portadoras de diferentes fatores de virulência. / The objective was to evaluate the action of indole-3-acetic acid (IAA) in the absence and presence of horseradish peroxidase (HRP) on the viability of certified strains of Staphylococcus aureus ATCC 6538 (producer of biofilm), ATCC 14458 (carrying the seb gene), ATCC 43300 (carrying the mecA gene) and ATCC29213 (control). Concentration was determined minimum inhibitory (CIM) and, after, we chose a concentration subinitória to assess the ability of biofilm formation, activity of antioxidant enzymes, integrity DNA, membrane integrity for all strains and evaluation of gene expression seb of strain ATCC 14458. The MIC for the strains ATCC 6538 was 40 mM IAA , for the strains ATCC 14458 and 29213 was 50 mM and for the strain ATCC 43300 was 60 mM IAA, however, significant differences (P<0.05) compared to the addition of HRP to the culture medium, was found only for the doses of MIC of the strains ATCC14458 and 43300. The concentration subinibitória IAA used was 30 mM for ATCC 6538 and ATCC 14458, and 40 mM to ATCC 43300 and ATCC 29213.mM for ATCC 6538 and ATCC 14458, and 50 mM to ATCC 43300 and ATCC 29213.The ability of biofilm formation by S. aureus(biofilm-positive) was not altered by the presence of IAA or IAA/HRP in the culture medium. The activity of catalase and superoxide dismutase was influenced by the action of IAA and IAA/HRP (P<0.05), but there was no difference (P≥0.05) between IAA and IAA/HRP. The DNA remained intact, however, there were changes (P<0.05) in the membrane integrity of microorganisms to sub-inhibitory concentrations of IAA and IAA/HRP, as well as the expression of the sebgene was lower (P<0.05) in microorganisms treated with IAA and IAA/HRP. It is concluded that the IAA has bacteriostatic effect on S. aureus carrying different virulence factors.
49

MACS (Magnetic Activated Cell Sorting) antes ou após a centrifugação em gradiente de densidade para o preparo seminal / Magnetic Activated Cell Sorting before or after the density gradient for the seminal prepared

Berteli, Thalita Souza 13 March 2017 (has links)
Estudos recentes avaliaram o papel do Magnetic Activated cell Sorting (MACS, separação celular por ativação magnética) para reduzir a percentagem de espermatozoides apoptóticos e melhorar a qualidade seminal. No entanto, a eficiência do uso do MACS isoladamente, antes ou depois do processamento seminal pelos métodos clássicos, como o centrifugação em gradiente de densidade (DGC), ainda não foi estabelecida, de modo que o protocolo de uso do método não foi adequadamente estabelecido. Desta forma, o objetivo do presente estudo foi avaliar se o MACS sozinho, antes (MACS-DGC) ou depois do processamento seminal pelo DGC (DGC-MACS) melhora a seleção espermática quando comparado ao processamento pelo DGC. Realizou-se um estudo prospectivo experimental avaliando amostras de sêmen de 15 homens saudáveis. A mesma amostra foi dividida em 4 alíquotas e processada por: DGC, DGC-MACS, MACS-DGC e MACS. Após o processamento, foram analisadas a integridade do DNA espermático pelo método TUNEL - TdT-mediated dUTP Nick End Labeling (marcação de quebras no DNA por dUTP e deoxinucleotidil terminal transferase) assim como a concentração de espermatozoides, a motilidade progressiva e a morfologia, segundo os últimos critérios adotados pela Organização Mundial da Saúde. A percentagem de dano ao DNA foi significativamente menor no grupo MACSDGC, quando comparado com DGC e MACS, e semelhante a do grupo DGC-MACS. A concentração de espermatozoides recuperados nos grupos de DGC e MACS foi similar e significativamente maior do que MACS-DGC e DGC-MACS, que foram semelhantes entre si. A motilidade progressiva dos espermatozoides recuperados foi semelhante nos grupos MACS-DGC e DGC e significativamente maior do que nos grupos DGC-MACS e MACS. O percentual de espermatozoides com morfologia normal foi significativamente maior no grupo MACS-DGC quando comparado ao DGC-MACS e MACS, e semelhante quando comparado com DGC. Desta forma, evidenciou-se que ambos os métodos combinados promovem a recuperação de espermatozoides com menor percentagem de dano ao DNA espermático. O MACS isoladamente ou aplicado após o DGC promove redução significativa dos espermatozoides progressivos recuperados, assim como da percentagem de espermatozoides com morfologia normal. Todavia, o MACS aplicado antes do DGC promove a recuperação de amostras com elevada percentagem de espermatozoides com motilidade progressiva e morfologia normal, aliada a baixa percentagem de DNA fragmentado, sugerindo ser o melhor protocolo de uso desta metodologia, cuja importância clínica precisa ser avaliada em estudos clínicos bem delineados. / Recent studies evaluated the role of Magnetic Activated Cell Sorting (MACS) in order to reduce the percentage of apoptotic sperm and improve seminal quality. However, the effectiveness of using MACS alone, before or after seminal processing by classical methods, such as the density gradient centrifugation (DGC), has not yet been established. Thus, the role of the present study was evaluate whether: MACS alone, before (MACS-DGC) or after seminal processing by DGC (DGC-MACS) improves sperm selection when compared to DGC. A prospective experimental study was conducted evaluating semen samples from 15 healthy men. The same sample was divided into 4 aliquots and processed by: DGC, DGC-MACS, MACS-DGC and MACS. After processing, the integrity of the sperm DNA was analyzed by TUNEL - TdT - mediated dUTP method Nick End Labeling (marking DNA breaks by dUTP and deoxynucleotidyl terminal transferase), sperm concentration, progressive motility and morphology according to the last criteria adopted by the World Health Organization. The percentage of DNA damage was significantly lower in the MACS-DGC group, when compared to DGC and MACS, and similar to the DGC-MACS group. The concentration of spermatozoa recovered in the DGC and MACS groups was similar and significantly higher than MACS-DGC and DGC-MACS, which were similar to each other. The progressive motility was similar in the MACS-DGC and DGC groups and significantly higher than in the DGC-MACS and MACS groups. The percentage of spermatozoa with normal morphology was significantly higher in the MACS-DGC group when compared to DGC-MACS and MACS, and similar when compared to DGC. Thus, it was evidenced that both methods combined promote the recovery of spermatozoa with a lower percentage of DNA damage. MACS alone or applied after the DGC promotes a significant reduction of the progressive sperm retrieved, as well as the percentage of spermatozoa with normal morphology. However, the MACS applied before the DGC promotes the recovery of samples with a higher percentage of spermatozoa with progressive motility and normal morphology, combined with low percentage of fragmented DNA, suggesting to be the best protocol, whose clinical importance needs to be evaluated in well-delineated clinical studies.
50

Procedimento de avaliação de integridade estrutural de juntas soldadas circunferenciais em tubulações submarinas rígidas submetidas à flexão. / Fracture assessment procedure of pipe girth welds subjected to bending load.

Souza, Rodolfo Figueira de 11 April 2016 (has links)
A demanda crescente por energia tem motivado a procura por petróleo e gás natural em ambientes com condições extremas, como operações em águas profundas e o transporte de fluídos corrosivos. Avanços tecnológicos recentes favorecem o uso de tubos de aço contendo uma camada interna resistente a corrosão (comumente chamados de Lined ou Clad Pipes) para o transporte de tais fluidos agressivos. Além disso, as tubulações submarinas são sujeitas a condições de instalação muito severas e, um caso de interesse, é o procedimento de reeling que permite com que a fabricação e inspeção da tubulação seja feita em terra. Apesar de possuir vantagens econômicas, a avaliação da integridade estrutural e especificação dos tamanhos toleráveis de trinca em juntas soldadas, nestas condições, torna-se uma tarefa complexa, devido a natureza dissimilar dos materiais e ao grande nível de deformação plástica no processo. Dessa maneira, este trabalho tem por objetivo o desenvolvimento de um procedimento de avaliação de forças motrizes elasto-plásticas em tubos contendo juntas soldadas circunferenciais sujeitos a flexão, para uma extensa gama de configurações geométricas. Dois métodos distintos foram desenvolvidos e analisados: a metodologia EPRI e o procedimento que utiliza a curva de tensão vs. deformação equivalente. As análises numéricas 3D fornecem os parâmetros de fratura necessários para a resolução do problema e a acurácia dos procedimentos é verificada a partir de estudos de casos e análises paramétricas. / The increasing demand for energy has motivated the oil and natural gas exploration in very hostile environments, including very deep water operation and the transport of corrosive fluids. Technological advances favor the use of high strength steel pipelines either clad or mechanically lined with a corrosion resistant alloy (CRA), such as Alloy 625, for the transport of corrosive hydrocarbons. Moreover, these pipelines are subjected to severe installation conditions and a case of interest is the pipe reeling process, which allows pipe welding and inspection to be conducted at onshore facilities. While cost effective, fracture assessments and specification of critical flaw sizes for the girth welds of lined/clad pipes are more complex due to the dissimilar nature of these materials and the high levels of plastic strain imposed during installation. In particular, effective analyses of crack driving forces in undermatched or partially mismatched pipe girth welds remain essential to determine more accurate acceptable flaw sizes for the piping system based upon conventional ECA procedures. This work focuses on the development of a procedure to determine the elastic-plastic crack driving forces for pipe girth welds with circumferential surface cracks subjected to bending load for a wide range of geometries and weld mismatch levels based upon based methodologies: the GE-EPRI framework and the equivalente stress vs. strain curve. The study also addresses the potential effects of an undermatching girth weld on critical flaw sizes. The extensive nonlinear, 3-D numerical analysis provide the fracture parameters for cracked pipes and cylinders with mismatched girth welds which will be applied in case studies and parametric analyses in order to verify the accuracy of the methods.

Page generated in 0.131 seconds