• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 166
  • 4
  • 1
  • Tagged with
  • 172
  • 121
  • 27
  • 27
  • 22
  • 22
  • 20
  • 20
  • 19
  • 16
  • 16
  • 16
  • 15
  • 15
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Efluxo de metano em solo sob manejos de irrigação e cultivares de arroz irrrigado / Cultivars and soil irrigation management into methane efflux of irrigated rive fieldsCULTIVARS AND SOIL IRRIGATION MANAGEMENT INTO METHANE EFFLUX OF IRRIGATED RICE FIELDS

Mortele, Diovane Freire 19 December 2011 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / Human activity has been pointed out as the main reason of global warming by effluxes of CO2, N2O and CH4. In the last years, harmful effects of greenhouse gases due to its increase in atmosphere have been arousing interests of scientists into propose mechanisms of mitigation. Flooding rice is responsible for about 12% of CH4 released to atmosphere and therefore, is considerate one of the most important source of this greenhouse gas. There are many factors that control CH4 efflux in irrigated rice fields, which difficult an accurate identification of the responsible mechanisms. However, is known that irrigation regime and selection of rice cultivars affect CH4 efflux and may be managed intending to mitigate it. The objectives of this thesis were: (a) verify the effect of continuous irrigation, intermittent irrigation and intermittent flooding into CH4 efflux of a hapludalf soil cultivated with flooding rice at central region of Rio Grande do Sul State; (b) evaluate CH4 efflux of rice cultivated in greenhouse under different irrigation managements and relate the efflux to agronomic parameters of rice plants; (c) evaluate the irrigation systems over the rice crop and how it affect the electrochemical of soil solution and plant development; (d) evaluate CH4 efflux through cultivars of rice from Rio Grande do Sul and Santa Catarina States and relate it to plant morphological attributes. Intermittent irrigation was efficient to mitigate CH4 efflux in rice cultivations, when the lack of rain did not establish water layers, without having decrease in rice productivity. intermittent flooding management by irrigations, even at saturated soil, decreased the CH4 efflux by 70%. The management of intermittent flooding by irrigations when soil was bellow the field capacity do not cause CH4 efflux, however, this management caused decrease of rice productivity. Irrigation management does affect electrochemical conditions of soil, which are determinant to the CH4 production in soils. The dynamic of efflux of CH4 is similar between cultivars; however, there are differences on potential of CH4 efflux from cultivars of flooding rice. The cultivars Arize 1003, Avaxi Cl, BRS Atalanta, BRS Querência, BRS Taim, Inov Cl, Irga 422 and Irga 424 have showed lower efflux and higher productivities. Morphological characteristics of plants have not explained completely the differences of CH4 effluxes between cultivars. / A atividade antrópica tem sido apontada como a principal causa do aquecimento global pelo efluxo de CO2, N2O e CH4. Nos últimos anos, os efeitos prejudiciais do aumento da concentração atmosférica desses gases têm despertado os cientistas a propor mecanismos de mitigação. A cultura do arroz irrigado por alagamento é responsável por cerca de 12% do efluxo total de CH4 para a atmosfera, sendo considerada uma das principais fontes emissoras desse gás de efeito estufa. Os fatores que controlam o efluxo de CH4 no arroz irrigado são muitos, dificultando identificar com precisão os mecanismos responsáveis pelo seu efluxo. O regime de irrigação e a seleção de cultivares de arroz são fatores que afetam o efluxo de CH4 e podem ser modificados visando mitigar os efluxos para a atmosfera. Os objetivos da tese foram: (a) verificar o efeito do regime de irrigação contínua, intermitente e a banhos no efluxo de CH4 em um Planossolo cultivado com arroz irrigado por alagamento na Depressão Central do Rio Grande do Sul; (b) avaliar o efluxo de CH4 no arroz cultivado em casa de vegetação submetido a diferentes manejos de irrigação e relacionar o efluxo com parâmetros agronômicos da planta de arroz; (c) avaliar os sistemas de manejo de irrigação na cultura do arroz e os efeitos nos atributos eletroquímicos da solução do solo e no desenvolvimento das plantas; (d) avaliar o efluxo de CH4 em cultivares de arroz do RS e SC e relacionar com atributos morfofisiológicos das cultivares; e (e) caracterizar morfologicamente a cultura do arroz e verificar a provável rota de difusão do CH4 do solo até a atmosfera. A prática da irrigação intermitente foi eficiente em mitigar o efluxo de CH4 no cultivo do arroz irrigado quando as condições climáticas permitiram a ausência da lâmina de água durante o cultivo, sem diminuir a produtividade do arroz. O manejo da irrigação intermitente com o realagamento do solo ainda saturado diminuiu a emissão de CH4 em 70%. O manejo intermitente da irrigação com o realagamento do solo abaixo da capacidade de campo não causa efluxo de CH4, porém os efeitos foram negativos sobre a produtividade do arroz. O manejo da irrigação afeta as condições eletroquímicas do solo e são determinantes para a produção de CH4 nos solos. A dinâmica de efluxo de CH4 é semelhante entre as cultivares, porém, existem diferenças no potencial de efluxo de CH4 em cultivares de arroz irrigado por alagamento. As cultivares Arize 1003, Avaxi Cl, BRS Atalanta, BRS Querência, BRS Taim, Inov Cl, Irga 422 e Irga 424 apresentaram menor efluxo de CH4 com a maior produtividade do arroz. As características morfofisiológicas das plantas não explicaram completamente as diferenças de efluxos de CH4 entre as cultivares.
142

Lesões em DNA promovidas por ácido 5-aminolevulínico: uma proposta de bases moleculares para hepatomos associados a porfirinopatias / DNA damage induced by 5-aminolevulinic acid: a molecular basis proposal for the hepatomas associated to porphyrinopathies

Janice Onuki 01 August 2000 (has links)
O ácido 5-aminolevulínico (ALA) é o primeiro precursor do grupo heme acumulado, principalmente no fígado, em alguns tipos de porfirias hepáticas hereditárias (porfiria aguda intermitente-AIP e tirosinemia) ou adquiridas (intoxicação por chumbo) devido à diminuição da atividade da enzima porfobilinogênio deaminase. Amostras de biópsias de fígado de pacientes portadores de AIP revelaram alterações estruturais nas mitocôndrias e no retículo endoplasmático, acúmulo de lipofuscina, gordura e corpúsculos de ferritina. Têm sido demonstrado que mutações mitocondriais induzidas por pró-oxidantes também contribuem para o envelhecimento celular e para o desenvolvimento do câncer. Esses dados podem estar relacionados à maior incidência de carcinoma hepatocelular (HCC) em pacientes sintomáticos de AIP. In vitro, ALA produz espécies reativas de oxigênio (ROS), através da oxidação catalisada por metais, e pode ser visto como uma fonte endógena de ROS, iniciando danos oxidativos a estruturas celulares como o DNA, podendo estar envolvido na iniciação e promoção do câncer. Além disso, o produto final de oxidação do ALA, o ácido 4,5-dioxovalérico (DOVA) é capaz de induzir modificações nas bases do DNA como outros derivados carbonílicos reativos. Neste estudo, demonstramos que o ALA é capaz de produzir danos ao DNA como quebras de fita de DNA plasmidial, aumento do nível de 8-oxo-7,8- dihidro-2\'-desoxiguanosina e 5-hidroxi-2´-desoxicitidina em DNA de órgãos de ratos tratados com ALA e aumento da formação de diversas bases modificadas em DNA de timo de bezerro. O DOVA reagiu com 2´-desoxiguanosina e DNA de timo de bezerro isolado produzindo dois adutos diastereoisômeros. O ALA e o DOVA foram capazes de aumentar a mutagenicidade em S. typhimurium TA104 e induzir resposta SOS em E. coli PQ37. Danos ao DNA mitocondrial e nuclear também foram detectados através da técnica de reação quantitativa em cadeia da polimerase em fibroblastos humanos transformados tratados com ALA. Todos esses dados fornecem informações referentes ao potencial genotóxico do ALA e permitem estabelecer uma proposta de bases moleculares para conectar as lesões ao DNA promovidas pelo ALA com a maior incidência de carcinoma hepatocelular em pacientes sintomáticos de AIP. / 5-Aminolevulinic acid (ALA) is a heme precursor accumulated in some inborn (acute intermittent porphyria-AIP and tyrosinosis) or acquired (lead poisoning) types of hepatic porphyria. In AIP patients, ALA is overproduced and accumulated in the liver. Liver biopsy samples of AIP patients revealed mitochondrial and endoplasmic reticulum structural alterations and accumulation of lipofucsin, fat and ferritin bodies. Mitochondrial mutations induced by pro- oxidants were suggested to contribute to cellular aging and cancer. These findings may be connected to the higher frequency of hepatocellular carcinoma (HCC) associated to symptomatic AIP patients. In vitro, ALA produces reactive oxygen species (ROS) upon metal- catalyzed oxidation and can be viewed as a deleterious endogenous source of ROS, triggering oxidative damage to cell structures and organs and being involved in the initiation and promotion of cancer. Besides, the final oxidation product of ALA, the 4,5-dioxovaleric acid (DOVA) is expect to induce DNA base modifications as already shown for other reactive carbonyl derivatives. In this study we demonstrated that ALA is able to produce DNA lesions such as strand breaks in plasmid DNA, increased steady state level of 8-oxo-7,8- dihydro-2\'-deoxyguanosine and 5-hydroxy-2´-deoxycytidine in rat organs DNA of ALA-treated rats and increased formation of several modified DNA bases in calf thymus DNA. 4,5-Dioxovaleric acid was showed to react with 2\'-deoxyguanosine and isolated calf thymus DNA through Schiff?s base formation to produce two diastereisomeric adducts. Aminolevulinic acid and DOVA were able to increase mutagenicity of the S. typhimurim strain TA104 and induce SOS response in E. coli PQ37. The mitochondrial and nuclear DNA damage were also detected by quantitative polymerase chain reaction technique in transformed human fibroblasts treated with ALA. All these data provide additional information on the genotoxic potential of ALA and reinforce the hypothesis that ALA may be involved in the induction of HCC in symptomatic AIP patients.
143

[pt] AVALIAÇÃO DO COMPORTAMENTO DINÂMICO DE SISTEMAS ELÉTRICOS DE POTÊNCIA COM PENETRAÇÃO DE FONTES RENOVÁVEIS CONSIDERANDO DISPOSITIVOS DE ARMAZENAMENTO DE ENERGIA / [en] DYNAMIC ASSESMENT OF ELECTRIC POWER SYSTEMS WITH RENEWABLE SOURCES AND ENERGY STORAGE DEVICES

IGOR DE OLIVEIRA BARRETO 20 August 2020 (has links)
[pt] O aumento da penetração de fontes de energia intermitentes é uma realidade dentro da matriz energética brasileira. A utilização em larga escala de energia renovável diminui a flexibilidade operativa com a redução da inércia equivalente sincronizada no sistema, podendo colocar em risco a segurança e a qualidade do suprimento de energia dos sistemas elétricos de potência com a diminuição da capacidade de regulação de frequência. Com expectativas de crescimento acentuado, surgem os dispositivos de armazenamento de energia (Energy Storage Devices – ESD) como uma alternativa viável para contornar essas dificuldades, principalmente quando se trata de um sistema de potência isolado. Nesta dissertação, avalia-se o comportamento dinâmico do sistema elétrico do estado de Roraima, através de uma metodologia desenvolvida para quantificar a penetração de energia renovável intermitente em sistemas isolados. Avalia-se também como a utilização de dispositivos de armazenamento de energia podem contribuir para o controle de frequência, observando as vantagens que tais dispositivos podem acarretar nesse sistema. A construção do Mapa de Decisão pode auxiliar as análises tanto na etapa de planejamento como na fase de programação e operação dos sistemas. Nas simulações realizadas foi possível constatar que a utilização de ESD pode promover um aumento significativo na penetração de usinas renováveis intermitentes, como eólica e solar fotovoltaica, em sistemas de potência isolados / [en] The increase in the penetration of intermittent energy sources is a reality within the Brazilian energy matrix. The large-scale use of renewable energy decreases the operational flexibility with the reduction of the equivalent inertia synchronized in the system, which can endanger the safety and quality of the energy supply of electric power systems with the reduction of the frequency regulation capacity. With expectations of sharp growth, energy storage devices (ESD) appear as a feasible alternative to overcome these difficulties, particularly when it comes to an isolated power network. In this dissertation, the dynamic assessment of the electrical system of the state of Roraima is evaluated, using a methodology developed to quantify the penetration of intermittent renewable energy in isolated systems. It is also evaluated how the use of energy storage devices can contribute to frequency control, observing the advantages that such devices can bring to this system. The construction of the Decision Map can assist the analyses during the planning, programming and operation phases. In the simulations carried out, it was possible to verify that the use of ESD can promote a significant increase in the penetration of intermittent renewable plants, such as wind and solar photovoltaic, in isolated power systems.
144

[pt] MEDIÇÃO DO CAMPO TRI-DIMENSIONAL DE VELOCIDADE DA FASE LÍQUIDA DE ESCOAMENTOS TURBULENTOS, GAS-LÍQUIDO, INTERMITENTES EM TUBO HORIZONTAL / [en] THREE-COMPONENT LIQUID VELOCITY FIELD MEASUREMENTS IN TURBULENT, GAS-LIQUID, INTERMITTENT FLOWS IN HORIZONTAL PIPES

RODRIGO DOS SANTOS NAVARRO DE MESQUITA 30 June 2020 (has links)
[pt] O estudo do escoamento intermitente de gás e líquido é de enorme relevância. Devido a sua vasta ocorrência em diversos problemas industriais, como na indústria do petróleo, em escoamentos de água e vapor em trocadores de calor e em sistemas de refrigeração de usinas nucleares, diversos estudos experimentais e numéricos buscam obter um conhecimento mais profundo deste complexo fenômeno. Devido a esta complexidade, se fazem necessários experimentos detalhados de maneira a dar suporte aos modelos matemáticos desenvolvidos. O presente trabalho descreve um estudo experimental de um escoamento turbulento gás-líquido no regime intermitente para tubo horizontal. As técnicas de velocimetria por imagem de partícula estereoscópica de alta frequência (SPIV ) e fluorescência induzida por laser (LIF) foram usadas para medir todos os três componentes do vetor de velocidade em diferentes seções do tubo, referenciadas pelo nariz da bolha de gás. A seção de testes consistiu de uma tubulação de acrílico com diâmetro interno de 40mm e 17,7m de comprimento. Os fluidos de trabalho utilizados foram água e ar, com velocidades superficiais de jL igual 0,3 0,4 e 0,5m/s e jG igual 0,5m/s que formaram o padrão de escoamento intermitente. Um sistema de sensores fotossensíveis foi utilizado para medir a velocidade de translação da bolha de gás, além de acionar o sistema SPIV. Desta forma, foi possível determinar os campos médios das três componentes de velocidade da fase líquida do escoamento turbulento gás-líquido em regiões de interesse na vizinhança da bolha alongada. Os dados obtidos revelaram a influência das bolhas de gás de maior velocidade, na dinâmica do campo de velocidade do líquido. Tais dados contém informações valiosas que contribuem não apenas para uma melhor compreensão da física que rege o escoamento, mas também como forma de validação e aprimoramento de modelos numéricos. / [en] The analysis of gas-liquid intermittent flow in horizontal pipes is of great relevance importance due its applications in many industrial problems, such as in the petroleum industry, boiler and heat exchanger tubes and cooling systems of nuclear power plants. A considerable number of experimental and analytical studies have been carried out on the pursuit of a deeper knowledge of this complex phenomenon. The present work describes an experimental study of a horizontal, gas-liquid pipe flow in the intermittent regime. Experimental techniques such as high frequency stereoscopic particle image velocimetry (SPIV ) and laser induced fluorescence (LIF), were applied in order to obtain all three components of the velocity vector at different pipe sections, referred to the gas bubble nose tip. A 40mm inner diameter, 17.7m long acrylic pipe was used as test section (L/D approximately 450). The working fluids, water and air formed the intermittent flow pattern, with superficial velocities of jL equal 0.3, 0.4 and 0.5 m/s and jG equal 0.5 m/s. A set of three photogate sensors, equally-spaced along the pipe, were used to measure the bubble translational velocities, and to trigger the SPIV system, allowing for the determination of ensemble-averaged, threecomponent velocity fields of the turbulent liquid flow in cross-stream planes around the gas bubble. The original data obtained revealed the influence of the faster-moving gas bubbles on the dynamics of the liquid velocity field, providing valuable information that contribute to a better understanding of the physics governing the flow, also serving for the validation of numerical simulations.
145

Impacto do método de pastejo sobre o acúmulo de forragem, estrutura do dossel e respostas morfofisiológicas da Brachiaria híbrida Convert HD 364 / Impact of stocking method on forage accumulation, canopy structure and morphophysilogical responses of Mulato II brachiriagrass

Holschuch, Solange Garcia 07 February 2018 (has links)
Apesar de muitos estudos dos diferentes métodos de lotação, a definição de estratégias de manejo eficientes geralmente é embasada em respostas de experimentos realizados com cada método individualmente, e não com ambos impostos sob uma mesma base de comparação. Com o objetivo de fundamentar os argumentos existentes, este estudo avaliou os impactos dos métodos de lotação contínua e intermitente impostos sob duas metas de alturas médias em pastagem de capim Convert HD 364, com avaliações da estrutura e das características morfofisiologicas do dossel, assim como do acúmulo (AF) e taxa de acúmulo (TAF) de forragem durante o verão agrótológico. O delineamento experimental utilizado foi o de blocos completos casualizados, com três repetições, seguindo um arranjo fatorial 2 x 3 entre duas metas de altura média de dossel (20 e 30 cm) e três métodos de lotação: 1) lotação contínua (LC) mimetizada, com taxa de lotação variável; 2) lotação intermitente (i.e., pastejo rotativo) com desfolhação leniente (remoção de ~ 40% da altura de dossel no pré-pastejo) (LIDL); e 3) lotação intermitente (i.e., pastejo rotativo) com desfolhação severa (remoção de ~ 60% da altura de dossel no pré-pastejo) (LIDS), respectivamente impostos por amplitudes de ±10, 25 e 40% entorno das metas de altura média de dossel, totalizando 18 unidades experimentais (piquetes) de 200 m2. Pastos manejados sob LC apresentaram maior AF e TAF (7410 kg MS ha-1 e 87 kg MS ha-1 dia-1, respectivamente). A interceptação de luz pelo dossel foi maior nos pastos sob LC (97%) do que naqueles sob LIDL e LIDS (93,7%) quando comparados nas metas de altura média do dossel (20 e 30 cm). No entanto, em pré-pastejo, os pastos sob LIDL e LIDS apresentaram 99% de interceptação de luz pelo dossel. Alterações com o mesmo padrão de respostas foram registradas para as proporções dos componentes da massa de forragem e índice de área foliar (IAF), com incremento significativo das proporções de lâmina foliar e colmos, assim como do IAF, e redução das proporções de material morto à medida que os pastos eram manejados sob menor intensidade em lotação contínua, ou havia o incremento da altura de pré-pastejo em lotação intermitente. Os métodos de lotação e as respectivas metas de altura não afetaram a taxa de fotossíntese de folhas individuais, mas a maior fotossíntese do dossel (69,35 μmol CO2 m-2 s-1) foi obtida nos pastos manejados sob LIDS com meta de altura média de 30 cm. Os pastos manejados sob LC apresentaram taxas de fotossíntese do dossel constantes (47 μmol CO2 m-2 s-1), o que resultou em maiores TAF e AF dentre os métodos de lotação estudados. / In spite of the great number of studies evaluating plant responses to different stocking methods, the definition of more efficient management strategies is generally based on the results of studies evaluating each stocking method separately. With the purpose of substantiating existing arguments, the present study evaluated the impacts of three stocking methods (1 - mimicked continuous stocking with variable stocking rate - CS; 2 - rotational stocking with lenient defoliation - removal of ~40% of pre-grazing canopy height - RSLD; 3 - rotational stocking with severe defoliation - removal of ~60% of pre-grazing canopy height - RSSD, respectively imposed by ±10, 25 and 40% variations) combined in a factorial arrangement with two mean canopy heights (20 and 30 cm) of Mulato II brachiariagrass, on canopy structure, morphophysiological characteristics, forage accumulation (FA) and forage accumulation rate (FAR) during the summer growing season. The experimental design was a randomized complete block with three replications, totaling 18 experimental units (paddocks) of 200 m2. Paddocks in CS treatments presented greater FA and FAR (7410 kg DM ha-1 and 87 kg DM ha-1 d-1, respectively). Canopy light interception was greater for paddocks in CS (97%) than for those in RSLD and RSSD (93.7%) for the two mean canopy heights. However, at pre-grazing, paddocks under RSLD and RSSD presented 99% of canopy light interception. The same response pattern was observed for forage mass composition and for leaf area index (LAI), with significant increases in the proportions of leaves and stems, as well as in LAI, and decreases in the proportions of dead material, as the grazing intensity decreased in CS, or as the pre-grazing height increased in the rotational stocking treatments. Neither the stocking methods, nor the mean canopy heights affected the photosynthesis rates of individual leaves, but the greatest canopy photosynthesis (69.35 μmol CO2 m-2 s-1) was obtained in paddocks under RSSD with mean canopy heights of 30 cm. Paddocks in CS presented constant canopy photosynthesis rates (47 μmol CO2 m-2 s-1), what lead to the greatest FAR and FA among the investigated stocking methods.
146

Estudo do funcionamento da ventilação assistida proporcional plus em um sistema pulmonar mecânico / Study of the functioning of the proportional assist ventilation plus in a mechanical lung model

Couto, Lara Poletto 13 August 2012 (has links)
INTRODUÇÃO: Ventilação assistida proporcional plus é um novo conceito de suporte ventilatório assistido que visa atuar de acordo com os níveis de esforço inspiratório, mecânica respiratória e níveis de porcentagem de apoio. A complexa interação entre esses fatores que comandam a sua função é de difícil interpretação na prática clínica. O objetivo deste estudo é provocar alterações na complacência, resistência e esforços inspiratórios, em um sistema pulmonar mecânico, para entender o funcionamento e as respostas desse modo nas suas diferentes porcentagens de apoio. MÉTODOS: No Laboratório de Ventilação Mecânica da Disciplina de Pneumologia da Faculdade de Medicina da Universidade de São Paulo, um ventilador Interplus da marca Intermed foi conectado em um pulmão mecânico da marca Michigan Instruments Inc, com a finalidade de gerar diferentes níveis de esforços inspiratórios e para disparar o ventilador Puritan-Bennett 840 da marca Covidien. Os volumes correntes expirados foram medidos e posteriormente comparados através do método estatístico ANOVA two-way, para 10 níveis de porcentagem de apoio (de 5% a 95%), 3 níveis de complacência (50, 100 e 150 mL/cmH2O), 3 níveis de resistência (5, 20 e 50 cmH2O/L/s) e 4 níveis de esforço inspiratório (-2, -5, -8 e -15 cmH2O). RESULTADOS: Trezentas e sessenta medidas de volume corrente expirado foram obtidas. Os volumes correntes expirados aumentaram significativamente com o incremento dos esforços inspiratórios, durante altos esforços inspiratórios e altas complacências. Diminuíram significativamente durante o incremento das resistências, especialmente quando combinado com baixos esforços inspiratórios e baixas complacências. O fenômeno de sobreassistência (runaway) ocorreu com porcentagem de apoio de 95% combinada com alta resistência e alta complacência. CONCLUSÃO: O modo ventilação assistida proporcional plus respondeu adequadamente às alterações provocadas nas complacências e nos esforços inspiratórios testados. Respondeu à situações de resistência extremamente alta somente quando associado com altos esforços inspiratórios. Não houve fenômeno de sobreassistência em porcentagens de apoio menores que 95%. / BACKGROUND: Proportional assist ventilation plus (PAV+) is a new concept of assist ventilatory support conceived to act according to the levels of inspiratory efforts, respiratory mechanics and percentages levels of assistance. This complex interaction among the factors commanding its function is difficult to detect in clinical setting. This study aimed to provoke changes in compliance, resistance and inspiratory efforts in a lung simulator to understand the responses of PAV+ support. METHODS: In the Mechanical Ventilation Laboratory at University of São Paulo, an Inter Plus ventilator (Intermed ®) connected to lung simulator (Michigan Instruments Inc) acted triggering Puritan-Bennett 840 ventilator (Covidien ®) at different levels of inspiratory efforts. Expiratory tidal volumes were measured and compared (ANOVA-2-way) at 10 levels of PAV+ support (from 5% to 95%), 3 levels of lung simulator compliance (50, 100, 150 mL/cmH20), 3 levels of airway resistance (5, 20, 50 cmH20/L/s) and 4 levels of inspiratory effort ( -2, -5, -8, -15 cmH20). RESULTS: A total of 360 tidal volumes were measured. They increased significantly during increment of inspiratory efforts and during higher inspiratory efforts with higher compliances. They decreased significantly during respiratory resistance increments, especially when combined with low inspiratory efforts and compliances. Runaway occurred during PAV+ support of 95% combined with high respiratory resistance and compliance. CONCLUSIONS: PAV+ responded adequately to provoked changes in the tested respiratory compliances and inspiratory efforts. It responded to very high resistance only when associated with high inspiratory efforts. There was no runaway phenomenon during PAV+ assistance below 95%.
147

Direito fundamental ao trabalho digno e o contrato de trabalho intermitente

Laraia, Maria Ivone Fortunato 03 December 2018 (has links)
Submitted by Filipe dos Santos (fsantos@pucsp.br) on 2018-12-17T11:52:56Z No. of bitstreams: 1 Maria Ivone Fortunato Laraia.pdf: 1689216 bytes, checksum: bb1aff1784125d849eedf26f1a503a17 (MD5) / Made available in DSpace on 2018-12-17T11:52:56Z (GMT). No. of bitstreams: 1 Maria Ivone Fortunato Laraia.pdf: 1689216 bytes, checksum: bb1aff1784125d849eedf26f1a503a17 (MD5) Previous issue date: 2018-12-03 / The intermittent labor contract, provided for in the text of article 452-A of the Consolidation of Labor Laws, a mechanism added by labor reform (Law 13467/17), is a contract in which the rendering of service, with subordination, is not continuous, with periods of actual work and inactivity, and can be determined by hour, day or month of work and without a fixed journey. It was conceived to be one of the solutions found for the serious Brazilian economic crisis, since it aims to create jobs, modernize labor laws and increase the competitiveness of Brazilian companies, facing the demands of contemporary capitalism. The intermittent contract, as it was instituted, breaks with the logic of the standard employment bond and contributes to the precariousness of the employment relations, since it allows the use of labor in a discontinuous way; authorizes the payment of salaries lower than the minimum constitutionally guaranteed; violates the principles of human dignity and the social value of work, improves the social status of the worker and offends the right to paid annual leave, at least one third more than the normal salary of the worker, rendering building a free, fair and supportive society, with the eradication of poverty and the reduction of social inequalities, thus failing to promote the welfare of all. This paper presents a proposal for a bill, inspired by Portuguese and Italian legislation, in order to enable the intermittent employee to carry out fundamental social rights, especially human dignity / O contrato de trabalho intermitente, previsto no texto do artigo 452-A da Consolidação das Leis do Trabalho, dispositivo acrescido pela reforma trabalhista (Lei 13.467/2017), é um contrato em que a prestação de serviço, com subordinação, não é contínua, havendo períodos de efetivo trabalho e de inatividade, podendo ser determinado por hora, dia ou mês de trabalho e sem uma jornada fixa. Foi concebido para ser uma das soluções encontradas para a grave crise econômica brasileira, pois objetiva a criação de empregos, modernização das leis trabalhistas e o aumento da competitividade das empresas brasileiras, diante das exigências do capitalismo contemporâneo. O contrato intermitente, da forma como foi instituído, rompe com a lógica do vínculo de emprego padrão e contribui para a precarização das relações de emprego, pois permite a utilização da mão de obra de forma descontínua; autoriza o pagamento de salários inferiores ao mínimo constitucionalmente assegurado; viola os princípios da dignidade humana e do valor social do trabalho, da melhoria da condição social do trabalhador e ofende o direito do gozo de férias anuais remuneradas, com, pelo menos, um terço a mais do que o salário normal do trabalhador, inviabilizando a construção de uma sociedade livre, justa e solidária, com erradicação da pobreza e redução das desigualdades sociais, deixando, assim, de promover obem de todos. Neste trabalho, apresenta-se uma proposta de projeto de lei, inspirada nalegislação portuguesa e na italiana, com a finalidade de possibilitar ao empregado intermitente a efetivação dos direitos fundamentais sociais, especialmente a dignidade humana
148

"Avaliação objetiva da isquemia de membros superiores: uso do dinamômetro isocinético" / Objective evaluation of upper limbs ischemia: use of isokinetic dynamometer

Nakano, Livio 13 September 2005 (has links)
O objetivo deste trabalho é apresentar o teste de esforço com o dinamômetro isocinético na avaliação objetiva da isquemia funcional da doença arterial oclusiva de membros superiores (DAOMS). Reuniu-se 23 pacientes com DAOMS unilateral, no grupo 1. Sete pacientes, sem DAOMS foram selecionados como o grupo controle (grupo 2). Os membros testados sem DAOMS do grupo 1 e do grupo 2 não apresentaram diferença estatística. A comparação de cada membro dos pacientes do grupo 1, com e sem DAOMS mostrou que os membros com DAOMS apresentaram desempenho significativamente menor que os membros sem lesão. Este teste permite a avaliação objetiva da limitação causada pela DAOMS de forma segura e objetiva / The objective of this work is to present the results of a stress test using an isokinetic dynamometer in patients with occlusive arterial disease in upper limbs (OADUL). Group 1 has 23 patients with unilateral subclavian occlusive disease. Seven patients, without OADUL, were included in a control group (group 2). No statistically difference was found in all parameters studied between limbs without OADUL in groups 1 and 2. So, each arm in group 1 (with and without OADUL) were tested. For all these parameters, the SOD limbs presented significantly lower values than the control limbs. This test gives an objective grade of limitation of the muscle function in patients with OADUL
149

Estudo comparativo entre a ventilação mandatória intermitente sincronizada associada à ventilação com suporte pressórico e ventilação não invasiva em dois níveis pressóricos como métodos de supressão da ventilação mecânica no pós-operatório / Comparative study of sincrony intermitent mandatory ventilation associated to pressure support ventilation versus noninvasive positive pressure ventilation with bilevel, as an ventilatory weaning methods in cardiac surgery postoperative period

Lopes, Célia Regina 09 December 2005 (has links)
INTRODUÇÃO: A literatura tem postulado que a ventilação por pressão positiva não invasiva (VNI) pode facilitar o desmame de um grupo específico de pacientes. O objetivo deste estudo foi comparar a utilização da VNI como método alternativo na supressão da ventilação mecânica no pós-operatório de cirurgia cardíaca. MÉTODOS: Neste estudo prospectivo controlado e randomizado, foram estudados 100 pacientes submetidos a cirurgia de revascularização do miocárdio ou cirurgia valvar. Os pacientes foram admitidos na Unidade de Terapia Intensiva (UTI), sob ventilação mecânica e randomizados posteriormente em grupo estudo (n= 50), que utilizou VNI com dois níveis pressóricos após extubação, e grupo controle (n= 50), que utilizou a técnica convencional de supressão da ventilação mecânica. Foram analisados os tempos correspondentes à anestesia, cirurgia, circulação extracorpórea e ventilação mecânica na UTI. As variáveis gasométricas, hemodinâmicas e radiológicas foram avaliadas antes e após a extubação. RESULTADOS: Os grupos controle e estudo apresentaram comportamento semelhante quanto ao tempo de desmame ventilatório e as outras variáveis estudadas não apresentaram diferença estatística. A utilização da VNI por 30\' após a extubação, nos pacientes com atelectasias, promoveu diferença significativa na PaCO2 no grupo coronariano e na PaO2 no grupo submetido à cirurgia valvar. CONCLUSÃO: O tempo para supressão da ventilação mecânica foi similar nos grupos. Fatores extrísecos interferiram na evolução do desmame. O uso da VNI por 30 minutos após extubação apresentou diferença estatisticamente significante nas variáveis gasométricas em pacientes com atelectasias / INTRODUCTION: It was postulated that noninvasive positive pressure ventilation (NPPV) could facilitate ventilatory weaning in specific patients. The aim was to compare NPPV as alternative ventilatory weaning method with a standard ventilatory weaning protocol in the immediate postoperative period of cardiac surgery. METHODS: One hundred consecutive patients submitted to coronary artery bypass grafting or valvar surgery were addmitted in the Intensive Care Unit (ICU) and mechanicanically ventilated. They were randomly assigned to a study group (n=50) wich use NPPV witn bilevel presssure in the airways and a control group (n=50) witch used the conventional weaning thecnique. The outcome measures were anestesie, surgery, cardiopulmonar bypass and mechanical ventilation time. Arterial blood gases, hemodynamics and chest X-rays were assessed pre and post extubation. RESULTS: Weaning times were similar in both groups, and no differences were found in the studied variables. There were statistic significance considering PaCO2 in coronary and PaO2 in valvar group using NPPV 30\' after extubation, when atelectasis was detected. CONCLUSION: The ventilatory weaning time was similar in both groups. Extrinsics factors had interfered in weaning evolution. NPPV use during 30\' after extubation had statistical significance in gasometric variables in patients with athelectasis
150

Estudo controlado e randomizado entre o uso de ventilação por pressão positiva intermitente e pressão positiva contínua em vias aéreas em recém-nascidos pré-termo após a extubação traqueal / Randomized controlled trial comparing nasal intermittent positive pressure ventilation and nasal continuous positive airway pressure in premature infants after tracheal extubation

Komatsu, Daniela Franco Rizzo 06 September 2007 (has links)
Objetivos: Analisar a frequência de falha da extubação em recém-nascidos pré-termo em ventilação mecânica convencional após a extubação traqueal nos grupos submetidos a ventilação por pressão positiva intermitente por via nasal (nIPPV) e pressão positiva contínua em vias aéreas (nCPAP). Métodos: Foram estudados 72 recém-nascidos pré-termo portadores de insuficiência respiratória, com idade gestacional 750 gramas, que necessitaram de entubação traqueal e ventilação mecânica. Após terem preenchido os critérios de extubação, os recém-nascidos foram submetidos a nIPPV (n=36) ou nCPAP (n=36) de acordo com o resultado da randomização. Os parâmetros iniciais para os RN randomizados para nIPPV foram: FR = 12 ipm; PIP = 16 cm H20; PEEP= 6 cm H20; FiO2 ? 40%, e para aqueles randomizados para nCPAP foram P=6 cm H2O; FiO2 < 40%. O estudo foi finalizado após um tempo de extubação de 72 horas ou quando o RN preenchesse os critérios de falha na extubação. O projeto de pesquisa foi aprovado pela Comissão de Ética de ambos os Serviços. Resultados: A grande maioria dos RN recebeu pelo menos uma dose de surfactante exógeno (80,5% no grupo nIPPV e 83,3% no grupo nCPAP, P= 1). O tempo médio de permanência em ventilação mecânica também foi semelhante (6,2 e 7,3 dias, P= 0,59, respectivamente). Entre os 36 RN randomizados para nIPPV, 6 (16,6%) apresentaram falha de extubação em comparação a 11 (30,5%) dos 36 RN randomizados para nCPAP. Apesar de se ter observado redução relativa de risco de falha de extubação da ordem de 45% (IC 95%: 0,23 a 1,32) a favor da nIPPV, esta diferença não alcançou significância estatística. Constatamos uma chance de falha de extubação de 4,38 vezes no grupo nCPAP quando comparado ao grupo nIPPV após excluírmos os RN com peso de nascimento inferior a 1000 gramas, sendo esta diferença estatisticamente significativa (P= 0,045).Complicações gastrointestinais e neurológicas, além de outras complicações, não ocorreram nos recém nascidos pré-termo submetidos à nIPPV ou nCPAP após a extubação. Conclusões: Embora a distribuição de frequências de falha da extubação tenha mostrado numericamente um menor índice de falha nos RNPT submetidos a nIPPV em relação àqueles submetidos a nCPAP, não houve diferença estatísticamente significante entre os dois modos de suporte ventilatório após a extubação. Ao excluirmos da análise os RN com peso de nascimento inferior a 1000 gramas constatamos um aumento estatisticamente significante na chance de falha no grupo nCPAP. / Objetive: To analyze the frequency of failed extubation in premature infants following mechanical ventilation placed on either nasal intermittent positive pressure ventilation (nIPPV) or nasal continuous positive airway pressure (nCPAP) after endotracheal tube removal. Methods: Seventy two premature infants with respiratory insufficiency and gestacional age 750 grams, who needed endotracheal intubation and mechanical ventilation were studied. Once the babies reached the criteria for exubation, they were randomized to either nIPPV (n=36) or to nCPAP (n=36) in accordance with the randomization resulted. The inicial settings for those randomized to nIPPV were: rate=12; PIP=16 cm H20; PEEP=6 cm H20; FiO2 < 40%, and for those randomized to nCPAP were P=6 cm H2O; FiO2 < 40%. The study ended after 72 hours or when the infants reached the criteria of failure of the extubation. Ethical Approval was obtained from the Hospital. Results: Most received at least one dose of exogenous surfactant (80,5% in the nIPPV group and 83,3% in the nCPAP group, P= 1). The average time of mechanical ventilation also was similar (6.2 and 7.3 days respectively, P= 0.59). Of the 36 infants randomized to nIPPV, six (16,6%) failed extubation in comparison to 11 (30,5%) of the 36 newborn randomized to nCPAP. Although to have itself observed relative reduction of risk failure of extubation the order of 45% (95%CI: 0,23 to 1,32) in the group nIPPV, this difference did not reach significance statistics. We verified a increaset of failure extubation of 4,38 times in the nCPAP group when compared to the group nIPPV after excluded premature infant from birthweight less than 1000 grams, this difference was significant (P = 0,045). Gastrointestinal and neurological complications, beyond other complications, had no occurred in premature infants submitted to nIPPV or nCPAP after the extubation. Conclusions: Although the distribution of frequencies has numerically shown a lesser index of failure in premature infants submitted to nIPPV in relation to those submitted to nCPAP after extubation they did not have statistical significance difference between the two ways of ventilatory support. To the excluded of the analysis premature infant with birthweight less than 1000 grams, verified an increase significant in the failure extubation in the nCPAP.group .

Page generated in 0.0962 seconds