• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 166
  • 4
  • 1
  • Tagged with
  • 172
  • 121
  • 27
  • 27
  • 22
  • 22
  • 20
  • 20
  • 19
  • 16
  • 16
  • 16
  • 15
  • 15
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Cateterismo vesical intermitente limpo em crianças e adolescentes: análise da qualidade de vida do binômio cuidador-criança e dos fatores envolvidos / Clean intermittent bladder catheterization in children and adolescents: quality of life analysis of the caregiver-child binomial and the involved factors

Valéria Pastre Alencar 01 July 2016 (has links)
INTRODUÇÃO E OBJETIVOS: O cateterismo vesical intermitente limpo (CVIL) é método consagrado para o esvaziamento da bexiga em pacientes com disfunção vesico esfincteriana. Crianças com disrafismos neuromedulares podem evoluir com disfunção vesico esfincteriana e algumas necessitam do CVIL. Profissionais da saúde que prestam assistência a crianças e adolescentes em programa de cateterismo vesical intermitente não devem pautar suas atenções somente nos pacientes, mas também em seus cuidadores. Os objetivos deste estudo foram: analisar a qualidade de vida do binômio cuidador-criança e identificar fatores envolvidos na adesão e satisfação com o programa de cateterismo vesical intermitente limpo em crianças e adolescentes. MÉTODOS: A população estudada foi de 174 indivíduos sendo oitenta e sete crianças e adolescentes entre um e dezoito anos de idade em programa de CVIL, e oitenta e sete cuidadores principais. Os cuidadores responderam a um formulário com dados sociodemográficos e clínicos da criança ou adolescente e do cuidador e dados gerais relativos à prática do cateterismo vesical. Os cuidadores também responderam a três questionários, dois relativos à qualidade de vida, WHOQOL-bref (do cuidador) e PedsQLTM4. 0 (relato do cuidador referente à qualidade de vida da criança/adolescente) e um relacionado ao impacto na vida do cuidador, a Caregiver Burden Scale (CBS). As crianças e adolescentes responderam o PedsQLTM4. 0 (relato da criança). RESULTADOS: 55,1% dos cuidadores consideraram sua qualidade de vida boa ou muito boa, 47,2% afirmaram estar satisfeitos ou muito satisfeitos com a saúde. Entre as 24 facetas da qualidade de vida avaliada pelo WHOQOL-bref, o maior escore foi para a autoestima. Os fatores: doença crônica do cuidador (p=0,001; p=0,016), crianças com déficit cognitivo (p=0,001; p=0,018) e dependência na realização do CVIL (p=0,013; p=0,029) foram associados à piora na qualidade de vida do cuidador nas questões físicas e psicológicas, respectivamente. O escore global da CBS foi de 1,97±0,51, sendo o maior escore na dimensão ambiente (2,22 ± 0,73). Cuidadores acima de 40 anos apresentaram impacto negativo (p=0,040) na dimensão decepção. A dependência para locomoção da criança/ adolescente, baixa frequência do CVIL e não realizar o CVIL fora do domicílio têm impacto negativo na vida do cuidador na dimensão meio ambiente. Na avaliação da qualidade de vida das crianças/adolescentes obtiveram-se maiores escores em todas as dimensões pelas respostas das crianças quando comparadas às respostas dos seus cuidadores. Crianças independentes do uso de aparelhos para locomoção apresentaram melhor qualidade de vida, na percepção de seus cuidadores, em todos os domínios do PedsQLTM 4.0, com significância (p=0,015) no domínio atividade escolar. Crianças que realizam CVIL via conduto abdominal continente apresentaram melhor qualidade de vida na percepção dos cuidadores e das crianças, comparada com o CVIL por via uretral. 83,9% dos cuidadores relataram benefícios do CVIL, a maioria relacionada à melhora das condições físicas causadas pela disfunção vesico esfincteriana; 98,9% descreveram dificuldades, em geral relacionadas às questões sociais. CONCLUSÕES: O cuidador tem percepção positiva de sua QV, satisfação com a sua saúde e elevada autoestima, com impacto relacionado aos fatores: doença crônica do cuidador, crianças com déficit cognitivo, dependência da criança para a realização do CVIL e locomoção, baixa frequência do CVIL e não realizar o procedimento fora do domicílio. A QV da criança/adolescente é melhor percebida por elas do que pelos seus cuidadores. Crianças/adolescentes que realizam CVIL via conduto abdominal continente apresentaram melhor QV na percepção do binômio. O CVIL foi um procedimento considerado de fácil execução, a diminuição da incontinência urinária foi o principal benefício relatado, e as limitações para aquisição do material foram a principal dificuldade relatada pelo grupo estudado / INTRODUCTION AND OBJECTIVES: Clean intermittent catheterization (CIC) is the established method for bladder emptying in patients with visico sphincter dysfunction. Children with neurospinal dysraphism can develop bladder sphincter dysfunction and some require the CIC. Health professionals who provide care to children and adolescents in clean intermittent bladder catheterization program should not keep their attentions only on their patients but also on their caregivers. The objectives of this study were to analyze the quality of life of the caregiver-child binomial and identify factors involved in adherence and satisfaction with CIC program in children and adolescents. METHODS: The study population was of 174 subjects, eighty-seven children and adolescents aged one to eighteen years old in CVIL program and eighty-seven of the main caregivers. Caregivers responded to a form with demographic and clinical data of the children or adolescents as well as the caregivers and general data related to the practice of bladder catheterization. Caregivers also answered three other questionnaires, two related to quality of life, WHOQOL -BREF (caretaker) and PedsQLTM4.0 (caretaker report related to children and adolescent\'s quality of life) and a questionnaire about the impact on the caretaker\'s life, the Caregiver Burden Scale (CBS). Children and adolescents answered the PedsQLTM4.0 (reported by children). RESULTS: 55.1 % of caregivers considered their quality of life good or very good, 47.2 % said they were satisfied or very satisfied with their health conditions. Among the 24 aspects of quality of life measured by WHOQOL -BREF, the highest score was for self-esteem. Factors: caregiver`s chronic disease (p = 0.001, p = 0.016), children with cognitive impairment (p = 0.001, p = 0.018), and dependence on the performance of CIC (p = 0.013, p = 0.029) were associated with worsening caregiver quality of life in physical and psychological issues, respectively. The overall score for CBS was 1.97 ± 0.51, with the highest score in the environment dimension (2.22 ± 0.73). Caregivers over 40 years old had a negative impact (p = 0.040) in the dimension of disappointment. The children and adolescents\' dependency for mobility, low frequency of CIC and nonperformance of CIC outside the household had a negative impact on the caregivers\' lives regarding the environment dimension. In the evaluation of children and adolescents\' quality of life, higher scores were obtained in all dimensions, considering the responses of children compared to the responses of their caregivers. Independent children \'s use of apparatus for locomotion had better quality of life scores, perception of their caregivers in all areas of PedsQLTM 4.0, with significance (p = 0.015) in the school activity. Children who perform CIC through abdominal continent conduit showed better quality of life as perceived by caregivers and children, compared with urethral CIC. 83.9 % of caregivers reported CIC benefits, most related to improving the physical conditions caused by bladder dysfunction; 98.9 % reported general difficulties related to social issues. CONCLUSIONS: The caregiver has a positive perception of their QoL, satisfaction with their health and higher self-esteem, with related to factors impact: chronic caregiver illness, children with cognitive impairment, the child\'s dependency on the performance of CIC and locomotion, low CIC frequency and not perform the procedure outside home. The child\'s QoL / adolescent is better perceived by them than by their caregivers. Children / adolescents who perform abdominal CIC via stoma had better QoL in the perception of binomial. The CIC was considered a procedure easy to perform, decreased urinary incontinence was the main benefit reported, and the limitations to the acquisition of the material were the main difficulty reported by the study group
132

Efeitos do pré-condicionamento à hipóxia sobre as alterações cardiovasculares e respiratórias promovidas por diferentes modelos de hipertensão experimental em ratos / Effects of preconditioning to hypoxia upon cardiovascular and respiratory alterations produced by different experimental models of hypertension in rats

Raphael Rodrigues Perim 03 July 2015 (has links)
Ratos jovens submetidos à hipóxia crônica intermitente (HCI) por um período de 10 dias apresentam hipertensão arterial e alterações no padrão de acoplamento das atividades simpática e respiratória. A exposição à HCI promove aumento da atividade simpática na fase expiratória final, mas o pico de atividade observado no final da inspiração/pós-inspiração também permanece. Estudos do nosso laboratório realizados em animais acordados mostraram por meio da análise espectral e do bloqueio ganglionar que a atividade simpática total está aumentada após um protocolo de 10 dias de HCI, caracterizando esse como sendo um modelo de hipertensão neurogênica. Em outros estudos voltados para verificar a reversibilidade da hipertensão arterial após o encerramento do protocolo de HCI, foi demonstrado que a pressão arterial desses animais se normaliza dentro de 15 dias em condição de normóxia. No entanto, estudos anteriores do nosso laboratório mostraram que a transmissão sináptica no núcleo do trato solitário permanece alterada mesmo após duas semanas de recuperação do protocolo de HCI. Sendo assim um dos objetivos desse trabalho foi avaliar as respostas cardiovasculares e respiratórias de ratos submetidos a um novo protocolo de HCI depois de 15 dias do encerramento do primeiro protocolo. Adicionalmente, avaliamos se as respostas cardiovasculares e respiratórias induzidas pela HCI seriam ou não influenciadas pelo pré-condicionamento com hipóxia mantida (HM). Assim como na HCI, nos modelos de hipertensão neurogênica a principal causa associada ao aumento de pressão arterial é a hiperatividade simpática. Dentre esses modelos, podemos destacar a hipertensão renovascular 1 rim, 1 clipe (1R, 1C) e os ratos espontaneamente hipertensos (SHR). Nesse contexto, avaliamos também se a pré-exposição à HCI poderia influenciar as respostas cardiovasculares e respiratórias observadas nesses 2 modelos de hipertensão. Os resultados mostraram que o pré-condicionamento com HCI ou com HM não alterou as respostas cardiovasculares promovidas por uma subsequente exposição à HCI. Por outro lado, o nível de hipertensão promovido pelo modelo 1R, 1C foi significativamente menor em animais pré-condicionados com HCI, via inibição do tônus simpático vascular. O procedimento de desnervação renal praticamente eliminou o aumento de pressão arterial associado ao modelo 1R, 1C. Adicionalmente, após a remoção bilateral do corpúsculo carotídeo, o nível de hipertensão decorrente do modelo 1R, 1C foi o mesmo, independente do pré-condicionamento com HCI. Por outro lado, o pré-condicionamento com HCI não alterou o desenvolvimento da hipertensão arterial de ratos SHR. / Juvenile rats submitted to chronic intermittent hypoxia (CIH) during 10 days present hypertension and alterations in the sympathetic and respiratory coupling. Exposure to CIH produces sympathetic overactivity in the late expiratory phase, whereas the peak of activity observed at the end of inspiration/post-inspiration was also maintained. Studies from our laboratory performed in awake animals, using spectral analyses and ganglionic blockade showed that the total sympathetic activity is increased after CIH protocol, characterizing this as a neurogenic model of hypertension. Other studies, designed to verify the reversibility of hypertension at the end of the CIH protocol, showed that the arterial pressure normalizes within 15 days in normoxic conditions. Nevertheless, previous studies from our laboratory showed that the synaptic transmission in the nucleus of the solitary tract continues altered even after two weeks of recovery from the CIH protocol. Thus, one of our goals was to evaluate the cardiovascular and respiratory responses in rats submitted to a new CIH protocol 15 days after the first protocol. Additionally, we evaluated whether or not the cardiovascular and respiratory responses induced by CIH would be influenced by preconditioning with sustained hypoxia (SH). As in CIH, in other models of hypertension the main cause associated with the rise of arterial pressure relies on the sympathetic overactivity. Among those models are the renovascular hypertension 1 kidney, 1 clip (1K, 1C) and the spontaneous hypertensive rats (SHR). In this sense, another goal of this study was to evaluate whether a previous exposure to CIH could affect the cardiovascular and respiratory responses produced by the 1K, 1C and the SHR model. Our results are showing that preconditioning with either CIH or SH did not alter the cardiovascular response produced by a subsequent exposure to CIH. On the other side, the level of hypertension promoted by 1K, 1C was significantly reduced in CIH preconditioned rats, via inhibition of the vascular sympathetic tone. The procedure of renal denervation practically eliminated the rise in arterial pressure associated with 1K, 1C. Additionally, after bilateral carotid body removal, the level of hypertension observed in 1K, 1C rats was the same, regardless CIH preconditioning. However, preconditioning with CIH did not affect the development of hypertension in SHR.
133

Avaliação de parâmetros cardiovasculares e respiratórios durante o ciclo sono-vigília de ratos submetidos à hipóxia crônica intermitente / Evaluation of cardiovascular and respiratory parameters during the sleep-wake cycle of rats submitted to chronic intermittent hypoxia

Darlan da Silva Bazilio 19 February 2018 (has links)
A hipóxia crônica intermitente (HCI) é um modelo experimental no qual o quimiorreflexo é ativado a cada episódio de hipóxia, assim como em alguns casos de apneia obstrutiva do sono. A HCI promove aumento da atividade simpática, hipertensão e alterações no acoplamento simpático-respiratório no tronco encefálico. No presente trabalho estudamos os parâmetros cardiorrespiratórios concomitantemente com o ciclo sono-vigília em uma janela temporal de 3 horas no período do dia em que esses registros são feitos no nosso laboratório. Foram também registradas ao longo deste período as respostas cardiovasculares associadas a inspirações profundas (IPs) que acontecem normalmente nos ratos. Ratos Wistar (~ 250 g) foram divididos nos grupos HCI (n = 12) e controle (CTL) (n = 12). Os animais foram submetidos à cirurgia de implantação de eletrodos no crânio e nos músculos cervicais para obtenção de registros eletrocorticográficos (ECoG) e eletromiográficos (EMG), respectivamente, para determinarmos as fases do ciclo sono-vigília (vigília, sono NREM (non-rapid eye movement) e sono REM (rapid eye movement)). Um grupo de animais CTL (n=5) e outro de animais HCI (n=6) tiveram também eletrodos implantados nos músculos diafragma (DIA) e abdominal oblíquo (ABD) para registros da atividade muscular respiratória. Após 48 horas, o grupo HCI foi exposto a um protocolo de hipóxia intermitente durante 10 dias (6% de O2 por 40 s, a cada 9 min, 8 h/d), enquanto o grupo CTL foi mantido em normoxia (20,8% de O2) pelo mesmo período. No último dia do protocolo, os ratos tiveram uma artéria femoral canulada para registros de pressão arterial (PA). No dia seguinte, ECoG, EMG e a PA foram registrados por 3 horas para análise da latência para o sono, o tempo total em cada uma das fases do ciclo sonovigília, o número e a duração dos episódios de sono REM e os parâmetros cardiovasculares pressão arterial sistólica (PAS), pressão arterial diastólica (PAD), pressão arterial média (PAM) e frequência cardíaca (FC) nas diferentes fases do ciclo. Os parâmetros respiratórios foram registrados por 2 horas para análise de frequência respiratória (fR), volume corrente (VT) e volume minuto (VE) nas diferentes fases do ciclo sono-vigília. Os animais dos grupos utilizados para avaliação da atividade respiratória muscular foram registrados por 2 horas. O protocolo de 10 dias de HCIpromoveu alterações significativas apenas na duração dos episódios de sono REM nos ratos HCI. Entretanto, os animais do grupo HCI apresentaram níveis médios mais elevados de PAS (145,0 ± 1,8 vs 129,3 ± 2,2 mmHg), PAD (104,1 ± 1,7 vs 91,4 ± 1,8 mmHg), PAM (121 ± 9 vs 107,7 ± 1,9 mmHg) e FC (387, ± 5,4 vs 363,5 ± 8,7 bpm) no período de 3 horas de registro, sendo estes aumentos igualmente observados em todas as fases do ciclo sono-vigília. A HCI também promoveu aumento significativo de VT durante os sonos NREM (6,6 ± 0,2 vs 5,8 ± 0,2 mL/kg) e REM (6,4 ± 0,2 vs 5,3 ± 0,2 mL/kg), porém este parâmetro não foi significativamente diferente durante a vigília nos animais HCI em relação aos animais CTL. Ambos os grupos apresentaram expirações ativas apenas durante a vigília, porém estas foram muito mais frequentes nos animais HCI. Além disso, nos animais HCI as respostas de queda da PAM (-18 ± 0,8 vs -14 ± 0,6 mmHg) e aumento da FC (28,4 ± 1,8 vs 21,8 ± 1,1 bpm) associadas às IPs apresentaram maiores magnitudes em relação aos animais CTL, embora o intervalo temporal entre as IPs não tenha se alterado. Esses achados indicam que a HCI aplicada durante 10 dias promove alterações significativas na duração dos episódios de sono REM, aumento da PA e FC em todas as fases do ciclo sono-vigília, aumento do VT durante o sono, aumento da ocorrência de expirações ativas durante a vigília e aumento das respostas hemodinâmicas associadas às IPs. Portanto, as alterações cardiovasculares observadas após a HCI são decorrentes dos episódios repetidos de hipóxia que acontecem ao longo desse protocolo, mas não parecem ser dependentes de alterações no ciclo sono-vigília, pois ainda que a duração dos episódios de sono REM tenha sido maior nos ratos HCI, os parâmetros cardiovasculares se apresentaram igualmente elevados em todas as fases do ciclo sono-vigília desses animais. / Chronic intermittent hypoxia (CIH) is an experimental model in which the chemoreflex is activated at each episode of hypoxia, as observed in some cases of obstructive sleep apnea. CIH induces increased sympathetic activity, hypertension, and changes in the sympathetic-respiratory coupling in the brainstem. In the present study, we recorded cardiorespiratory parameters concomitantly with the sleep-wake cycle during a 3-hour time window which corresponds to the period of the day in which these recordings are collected in our laboratory. During this period, we also studied the cardiovascular responses associated with the normally occurring deep breaths (DBs) in rats. Male Wistar rats (~ 250 g) were divided into CIH (n = 12) and control (CTL) groups (n = 12). Animals underwent implantation of electrodes in the skull and in the cervical muscles for electrocorticographic (ECoG) and electromyographic (EMG) recordings, respectively, to determine the phases of the sleep-wake cycle (wakefulness, NREM sleep and REM sleep). A group of CTL animals (n=5) and another of HCI animals (n=6) had electrodes implanted also in the diaphragm (DIA) and oblique abdominal muscle (ABD) for recordings of respiratory muscle activity. After 48 hours, the CIH group was exposed to an intermittent hypoxia protocol for 10 days (6% O2 for 40 s, every 9 min, 8 h/d), while the CTL group was maintained in normoxia (20.8 % of O2) for the same period. On the last day of the protocol, rats had a femoral artery cannulated for blood pressure (BP) recordings. On the following day, ECoG, EMG and BP were recorded for 3 hours for analysis of time for sleep onset, total time in each phase of the sleep-wake cycle, number and duration of REM sleep episodes, and the cardiovascular parameters systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP) and heart rate (HR) in the different phases of the cycle. The respiratory parameters were recorded for 2 hours for analysis of ventilatory frequency (fR), tidal volume (VT) and minute volume (VE) in the different phases of the sleep-wake cycle. The groups of animals used for analysis of respiratory muscle activity were recorded for only 2 hours. CIH promoted significant alterations only in the duration of REM episodes. However, animals from CIH group had higher average levels of SBP (145,0 ± 1,8 vs 129,3 ± 2,2 mmHg), DBP (104,1 ± 1,7 vs 91,4 ± 1,8mmHg), MAP (121 ± 9 vs 107,7 ± 1,9 mmHg) e HR (387, ± 5,4 vs 363,5 ± 8,7 bpm) in the 3-hour recording period. These increases were also observed in all phases of the sleep-wake cycle. CIH also promoted a significant increase in VT during NREM (6,6 ± 0,2 vs 5,8 ± 0,2 mL/kg) and REM (6,4 ± 0,2 vs 5,3 ± 0,2 mL/kg), although this parameter was not significantly different during wakefulness in CIH animals compared to CTL animals. Both groups presented active expiration only during wakefulness, however it was much more frequent in HCI rats. In addition, in CIH animals, the fall in MAP (-18 ± 0,8 vs -14 ± 0,6 mmHg) and the increase in HR (28,4 ± 1,8 vs 21,8 ± 1,1 bpm) associated with DBs presented higher magnitudes in relation to CTL animals, although the time interval between DBs did not change. These findings indicate that CIH for 10 days promotes longer REM episodes, increased BP and HR in all phases of the cycle, increased VT during sleep, increased active expiration occurrence and higher magnitudes of the hemodynamic responses associated with DBs. Therefore, the cardiovascular alterations observed after CIH are due to the intermittent hypoxia episodes that occur throughout this protocol, but do not seem to be related to changes in the sleep-wake cycle, for although the duration of REM episodes was longer, the cardiovascular parameters were equally increased in all phases of the sleep-wake cycle.
134

Pré-condicionamento isquêmico remoto em portadores de claudicação intermitente de membros inferiores / Remote ischemic preconditioning in patients with intermittent claudication

Glauco Fernandes Saes 03 March 2016 (has links)
INTRODUÇÃO: Pré-condicionamento isquêmico remoto (PCIR) é o fenômeno pelo qual curtos períodos de isquemia sub-letal sobre um órgão ou tecido, intercalados com reperfusão do mesmo, conferem a outros órgãos ou tecidos distantes deste, um aumento na capacidade da resistir a episódios subsequentes de isquemia, a qual os mesmos possam ser expostos. Com base nesse fato, testamos a hipótese de que o pré-condicionamento isquêmico remoto em pacientes portadores de claudicação intermitente de membros inferiores poderia aumentar a capacidade de deambulação desses pacientes, extrapolando o conceito do PCIR de aumento da capacidade de preservação da integridade celular frente à isquemia, para a manutenção da função celular, tornando a célula mais apta ao trabalho em situações de privação de oxigênio, geradas pela restrição do fluxo sanguíneo, como ocorre nos pacientes com claudicação intermitente de membros inferiores, durante o exercício. OBJETIVOS: Avaliar se o PCIR aumenta a distância de início de claudicação e/ou a distância total de claudicação em pacientes com doença arterial obstrutiva periférica. MÉTODOS: Foram estudados 52 pacientes ambulatoriais que apresentavam queixa de claudicação intermitente dos membros inferiores, associada a um pulso arterial ausente ou reduzido no membro sintomático e/ou um índice tornozelo-braço <0,90. Estes pacientes foram randomizados em três grupos (A, B e C). Todos os pacientes foram submetidos a dois testes de caminhada em esteira de acordo com o protocolo de Gardner. O grupo A fez o primeiro teste de esteira sem o pré-condicionamento isquêmico remoto e, após 7 dias, foi submetido a um novo teste de esteira, agora precedido pelo pré-condicionamento isquêmico remoto. O grupo B foi submetido ao pré-condicionamento isquêmico remoto antes do primeiro teste de esteira e, após 7 dias, realizou novo teste de esteira, agora sem o pré-condicionamento isquêmico remoto. Já no Grupo C (grupo controle), ambos os testes de esteira foram realizados sem pré-condicionamento isquêmico remoto, também com 7 dias de intervalo. RESULTADOS: Os grupos A e C mostraram um aumento na distância de início de claudicação, no segundo teste, em comparação com o primeiro teste. O grupo A teve um aumento estatisticamente significativo, em relação ao grupo C (grupo controle). Com relação à distância total de claudicação, todos os grupos (A, B e C), mostraram um aumento estatisticamente significativo a favor do segundo teste, porém não foi observada diferença entre os grupos (A, B e C). CONCLUSÕES: O pré-condicionamento isquêmico remoto aumentou a distância inicial de claudicação em pacientes com claudicação intermitente, no entanto, ele não afetou a distância total de claudicação dos pacientes portadores de claudicação intermitente de membros inferiores / INTRODUCTION: Remote ischemic preconditioning (RIPC) is a phenomenon in which a short period of sub-lethal ischemia in one organ protects against subsequent bouts of ischemia in another organ. Extrapolating the RIPC concept of increasing the preservation of cell integrity capability against ischemia, for the maintenance of cellular function, making the cell more able to work in oxygen deprivation generated by the restriction of blood flow, as occurs in patients with intermittent claudication of the lower limbs during exercise, we hypothesized that RIPC in patients with intermittent claudication would increase muscle tissue resistance to ischemia, thereby resulting in an increased ability to walk. OBJECTIVES: To test this hypothesis, we performed gait tests in patients with claudication with and without prior RIPC and then compared the initial claudication distance (ICD) and the total walking distance (TWD). METHODS: In a claudication clinic, 52 ambulatory patients who presented with complaints of intermittent claudication in the lower limbs associated with an absent or reduced arterial pulse in the symptomatic limb and/or an ankle-brachial index < 0.90 were recruited for this study. The patients were randomly divided into three groups (A, B and C). All of the patients underwent two tests on a treadmill according to the Gardener protocol. Group A was tested first without RIPC. Group A was subjected to RIPC prior to the second treadmill test. Group B was subjected to RIPC prior to the first treadmill test and then was subjected to a treadmill test without RIPC. In Group C (control group), both treadmill tests were performed without RIPC. The first and second tests were conducted seven days apart. Brazilian Clinical Trials: RBR-7TF6TM. RESULTS: Group A and C showed an increase in the initial claudication distance in the second test compared to the first test. Group A had a statistically significant increase, compared with C group (control group). With respect to total claudication distance, all the groups (A, B and C) showed a statistically significant increase in favor of the second test, but there was no difference between groups (A, B and C). CONCLUSIONS: RIPC increased the initial claudication distance in patients with intermittent claudication; however, RIPC did not affect the total walking distance of the patients
135

Avaliação hemodinâmica e de extração de solutos comparando exercício físico e compressão pneumática durante hemodiálise / Evaluation of Hemodynamic and solute removal, a comparison between exercise and pneumatic compression during hemodialysis

Valéria Regina de Cristo Alvares 07 July 2017 (has links)
Introdução: à despeito da evolução dos aspectos técnicos do tratamento dialítico ao longo das últimas décadas, hipotensão intradialítica (HID) continua a ocorrer em uma parcela significante das sessões. Esquemas alternativos de diálise, especificamente sessões prolongadas e/ou frequentes tem se mostrado benéficas e se associam a um melhor controle da pressão arterial e da anemia, maior remoção de fósforo, regressão da hipertrofia ventricular esquerda, melhor controle de hipervolemia e aumento da sobrevida dos pacientes. A adoção destes métodos mais intensivos, entretanto, não é unânime e a maior parte da população em diálise no mundo realiza hemodiálise (HD) convencional 3 x semana. A HD convencional está associada à HID e à remoção ineficaz de fosfato. Como as pernas são a principal fonte de fluido extracelular removido durante o HD, procurou-se reduzir a HID e aumentar a remoção de fosfato usando exercício com cicloergômetro e compressão pneumática, o que potencialmente proporcionariam maior retorno venoso dos membros inferiores, preservando o fluxo sanguíneo central e também fazendo com que mais fosfato pudesse chegar ao dialisador, facilitando sua eliminação. Métodos: este é um estudo com intervenção, cruzado, onde foram avaliados 21 pacientes, em 3 diferentes sessões de HD: controle, exercício com cicloergômetro durante os primeiros 60 minutos de HD e compressão pneumática durante os primeiros 60 minutos de HD. Os dados avaliados foram: distribuição de fluidos (através de bioimpedância), pressão arterial hora a hora durante a HD, parâmetros bioquímicos e de remoção de fosfato (através de quantificação direta do dialisado). HID foi definida como uma queda na pressão arterial média (PAM) >= 20 mmHg. Resultados: não houve diferença na taxa de ultrafiltração (p = 0,628), delta de peso (p = 0,415), delta de água corporal total, intracelular e extracelular entre controle, cicloergômetro e compressão pneumática (p = 0,209, p = 0,348 e p = 0,467, respectivamente). Comparando controle, cicloergômetro e compressão pneumática, o delta de PAM foi menos negativo durante a compressão pneumática [-4,7 (-17,2, 8,2), -4,7 (-20,5, -0,2) e -2,3 (-8,1,9,0) mmHg, respectivamente; p = 0,021]. HID ocorreu em 43%, 38% e 24% dos pacientes em controle, cicloergômetro e compressão pneumática, respectivamente (p = 0,014). A remoção de fosfato não aumentou com nenhuma intervenção (p = 0,486). A remoção mais elevada de fosfato foi dependente da ultrafiltração, fosfato sérico pré-diálise e PTH mais elevado. Conclusão: A compressão pneumática durante a primeira hora de diálise foi associada a menor HID, embora não tenha sido observado efeito nos parâmetros de distribuição de fluidos. Nenhuma das intervenções testadas, seja exercício ou compressão pneumática conseguiu aumentar a remoção de fosfato / Introduction: Despite the evolution of the technical aspects of dialysis over the last decades, intradialytic hypotension (DIH) continues to occur in a significant proportion of the sessions. Alternative dialysis schemes such as prolonged and / or more frequent sessions have been shown to be beneficial and are associated with better control of blood pressure and anemia, greater phosphorus removal, regression of left ventricular hypertrophy, better control of hypervolemia, and increased survival of patients. The adoption of these methods, however, is not unanimous and the majority of the dialysis population worldwide are on conventional hemodialysis (HD) 3x week. Conventional HD is associated with DIH and it is also ineffective to remove phosphate. Since the legs are the main source of extracellular fluid removed during HD, we sought to reduce DIH and increase phosphate removal by using cycling exercise and pneumatic compression, which would potentially provide greater venous return from the lower limbs, preserving blood flow, and also offering more phosphate to the dialyser, facilitating its elimination. Methods: We evaluated 21 patients in a randomized crossover fashion in which each patient underwent 3 different HD: control; cycling exercise during the first 60-min; and pneumatic compression during the first 60-min. Data obtained included bioelectrical impedance, hourly blood pressure measurement, biochemical parameters, and directly quantification of phosphate through the dialysate. DIH was defined as a drop in mean arterial pressure (MAP) >= 20 mmHg. Results: There was no difference in ultrafiltration rate (p=0.628), delta weight (p=0.415), delta of total, intracellular and extracellular body water among control, cycling and pneumatic compression (p=0.209, p=0.348 and p=0.467, respectively). Delta MAP was less changed by pneumatic compression when compared to control, cycling and pneumatic compression, respectively [-4.7 (-17.2, 8.2), -4.7 (-20.5, -0.2) and -2.3 (-8.1,9.0) mmHg; p=0.021]. DIH occurred in 43%, 38% and 24% of patients in control, cycling and pneumatic compression, respectively (p=0.014). Phosphate removal did not increase in any intervention (p=0.486). Higher phosphate removal was dependent on ultrafiltration, pre-dialysis serum phosphate and higher PTH. Conclusion: Pneumatic compression during the first hour of dialysis was associated with less DIH, albeit no effect on fluid parameters was observed. Neither exercise nor pneumatic compression increased phosphate removal
136

Remoção de carbono e nitrogênio em reator de leito móvel submetido à aeração intermitente / Nitrogen and carbon removal in moving bed reactor operated under intermittent aeration

Lissa Maria Nocko 30 May 2008 (has links)
O lançamento de águas residuárias contendo compostos nitrogenados tem um importante impacto sobre a saúde e o meio ambiente, tornando necessária a incorporação de processos de remoção desses compostos nos sistemas de tratamento de águas residuárias. Neste trabalho, foram estudadas as condições de operação para promover a remoção conjunta de nitrogênio e matéria orgânica em reator biológico de leito móvel, contínuo, operado sob aeração intermitente, alimentado com água residuária sintética contendo nitrogênio amoniacal (90 a 110 mg/L) e melaço como matéria orgânica (DQO de 450 a 550 mg/L). Foram utilizados dois reatores em escala de bancada, cada um com dois litros de volume útil, contendo diferentes meios suportes para a imobilização da biomassa: matrizes de espuma de poliuretano e anéis plásticos. Na primeira etapa experimental, o reator contendo anéis plásticos apresentou eficiências de remoção de nitrogênio muito baixas. Na segunda etapa, trocou-se o material suporte por matrizes de espuma de poliuretano inoculadas com lodo aeróbio de estação de tratamento de águas residuárias. A partir de então, trabalhou-se com dois reatores de mesma configuração, exceto pelas origens, idades e características dos lodos de inóculo. Inicialmente, a alimentação foi realizada utilizando-se apenas os micronutrientes contidos no melaço. Posteriormente, a composição da água residuária foi alterada, introduzindo-se solução de micronutrientes, pois se concluiu que a instabilidade no processo de nitrificação devia-se ao fato de o melaço comercial apresentar deficiências nutricionais. Como resultado, em condições de estabilidade operacional, foram obtidas eficiências de remoção de DQO superiores a 85%, oxidação total do nitrogênio amoniacal e eficiências de remoção de nitrogênio de aproximadamente 55%. Variações posteriores nas condições de operação, como o aumento do período anóxico (de 1h para 1h15min) e redução do tempo de detenção hidráulica (para valores inferiores a 12 horas), resultaram em melhora no desempenho dos reatores. Os resultados obtidos permitem admitir que as melhores condições de operação não foram atingidas durante o experimento, abrindo a possibilidade para a otimização do processo em pesquisas futuras. Constatou-se que o desenvolvimento das populações microbianas imobilizadas no meio suporte foi diferente do observado na biomassa em suspensão. Verificou-se, também, que a biomassa responsável pela nitrificação e desnitrificação ocorreu predominantemente no meio suporte, enquanto que a biomassa heterotrófica predominou no lodo em suspensão. / The operating conditions for the combined removal of nitrogen and organic matter in moving- bed biological reactor were investigated. Two bench-scale reactors, two liters each, were operated under intermittent aeration and continuously fed with synthetic wastewater containing ammonia nitrogen (90 to 110 mg/L) and molasses as organic carbon source (COD of 450 to 550 mg/L). Each reactor received different moving-bed materials: polyurethane foam matrices and plastic rings, respectively. During the first experimental period, the reactor containing plastic rings maintained very low nitrogen removal efficiencies during large period. For this reason, the moving-bed was replaced by polyurethane foam matrices and the reactor was re-inoculated with aerobic wastewater plant sludge. Thereafter, the two reactors were similar except for the origin, age and characteristics of the inoculum sludge. First, the wastewater micronutrients were just those contained in the carbon source (molasses). After, the synthetic wastewater composition was changed by adding a solution of micronutrients. This procedure was adopted to achieve a stable nitrification process, because commercial molasses is a very poor regarding its micronutrient composition. As a result of the stable conditions prevalence just after adding micronutrients, organic matter (as COD) removal efficiencies were higher than 85% and complete nitrogen ammonia oxidation was achieved. In nitrogen removal efficiencies were approximately 55%. The performance of the reactors improved after the increase of the anoxic period from1h to 1h15min, and reduction of the hydraulic detention time to less than 12 h. The results obtained in the last operating period indicated the optimum operating conditions was not achieved in this experiment, thus opening the possibility of process improvement in further researches. Microbial populations with different characteristics were developed in suspended growth and attached biomass. Nitrification and denitrification bacteria predominated as attached biomass whereas heterotrophic bacteria predominated as suspended growth biomass.
137

Efeitos do tempo de aeração no desempenho de reator de leito estruturado e aeração intermitente usado para remoção de matéria orgânica e nitrogênio de efluente de reator UASB / Effects of aeration time in structured-bed reactor under intermittent aeration used to remove organic matter and nitrogen of a UASB reactor effluent

Bruno Garcia Silva 19 May 2016 (has links)
Utilizou-se reator de leito estruturado e aeração intermitente (RLEAI) como pós-tratamento de efluentes de reator UASB tratando esgoto sanitário. O volume total e o tempo de detenção hidráulica (TDH) do reator UASB eram de 11,2 L e 9 horas, respectivamente. O RLEAI possuía volume total de 11,0 L e, devido às hastes cilíndricas verticais de espuma de poliuretano usadas como suporte para a biomassa, o volume útil foi de 9,6 L. Este reator foi operado com um TDH de 12 horas, razão de recirculação igual a 3 e foi alimentado continuamente com efluente do reator UASB. O objetivo deste trabalho foi avaliar a influência do tempo de aeração no desempenho do RLEAI na remoção de matéria orgânica e nitrogênio. O reator foi operado com aeração contínua, e tempos de aeração intermitentes (tempo aerado/não aerado) de 2h/1h, 1h/1h, 0,75h/1,25h, 1h/ h e 1h/3h. Em todas as fases a DQO efluente ao sistema ficou entre 26 e 42 mg.L-1. A fase de aeração contínua foi fundamental para o estabelecimento da comunidade nitrificante no sistema. A oxidação do nitrogênio total (como NTK) para nitrato aumentou de 62% (aeração contínua ) para 82% (aeração intermitente de 1h/2h) devido à alcalinidade gerada pela desnitrificação, estimulada pelo período não aerado. Na fase 1h/3h a oxidação do NTK foi prejudicada pela falta de oxigênio, e a eficiência nesta fase foi de 42%. A maior remoção estável de N-total foi obtida na fase 1h/2h com eficiência de 29%. Foi observado no ensaio em batelada que a velocidade de desnitrificação via nitrato aumentou de 0,90 mg N. g SSV-1.h-1 para 2,55 mg N. g SSV-1.h-1 após aclimatação da biomassa em condições de excesso de matéria orgânica. Concluiu-se que a remoção de N-total foi limitada pela baixa quantidade de matéria orgânica advinda do reator UASB, sendo a relação DQO/N do afluente ao RLEAI de 3,04. A elevada oxidação de NTK e de remoção de matéria orgânica, aliadas à baixa produção sólidos e ao alto tempo de retenção celular (139 dias), mostram que o RLEAI é uma alternativa interessante em comparação às tecnologias praticadas atualmente para pós tratamento de efluentes de reatores anaeróbios. / This study used a structured bed reactor under intermittent aeration for post-treatment of UASB rector treating domestic sewage. The UASB reactor had a total volume of 11.2 L and 9 hours of hydraulic retention time (HRT). The structured bed reactor had a total volume of 11.0 L and working volume of 9.6 L due to the vertical cylindrical rods with polyurethane foam used as a support for the biomass. This reactor was operated whit 12 hours of HRT, recirculation ratio equal to 3 and was continuously fed with effluent from the UASB reactor. The aim of this study was to evaluate the influence of aeration time on RLEAI performance in removal of organic matter and nitrogen. For this the reactor was operated with continuous aeration and intermittent aeration periods (time aerated/ non-aerated) of 2h/1h, 1h/1h, 0.75h/1.25h, 1h/2h e 1h/3h. During all operation time the COD effluent to the system it was between 26 and 42 26 e 42 mg.L-1. The continuous aeration operation was fundamental to the establishment of the nitrifying microorganism community in the system. The TKN oxidation to nitrate increase from 62% (continues aeration) to 82% (intermittent aeration 1h/2h) due to the alkalinity generated by denitrification, that was stimulated by non-aerated period. In the intermittent aeration period of 1h/3h the NTK oxidation was damaged by a lack of oxygen; the efficiency at this stage was 42%. The most stable total nitrogen removal was obtained in 1h/2h aeration period with 29% efficiency. It was observed in the batch test that nitrate denitrification rate increased from 0.90 mg N. g VSS-1.h-1 to 2.55 mg N. g VSS-1.h-1 after acclimation of biomass in conditions of excess organic matter. It was inferred that the removal of total nitrogen was limited by the low amount of organic matter load from the UASB reactor; the COD/N ratio of the influent was 3.04. The high NTK oxidation and high organic matter removal, combined with low solid production and high cell retention time (139 days), leads to the conclusion that the structured bed reactor under intermittent aeration is an interesting alternative compared to the technologies currently applied for post treatment of anaerobic reactors effluent.
138

Prevalência de síndrome metabólica em pacientes com claudicação intermitente e sua correlação com o nível de obstrução arterial / Prevalence of metabolic syndrome in patients with intermittent claudication and its correlation with the segment of arterial obstruction

Antonio Eduardo Zerati 02 February 2011 (has links)
INTRODUÇÃO: O termo Síndrome Metabólica denomina um conjunto de fatores de risco cardiovascular associado à resistência à insulina e a um aumento da morbidade e da mortalidade. A síndrome metabólica está relacionada a diversas doenças, especialmente aquelas ligadas à aterosclerose, como a doença arterial periférica. A claudicação intermitente é sintoma característico de um estágio inicial da doença arterial periférica, no qual o conhecimento dos seus fatores predisponentes, entre os quais a síndrome metabólica, torna-se importante para a instituição do tratamento médico adequado, a fim de prevenir ou retardar a progressão da aterosclerose. OBJETIVO: O objetivo deste estudo transversal foi determinar a prevalência da síndrome metabólica em pacientes com claudicação intermitente e sua correlação com a idade, gênero, localização da obstrução arterial e associação com doença arterial coronária sintomática. MÉTODO: Foram estudados 170 pacientes com doença arterial obstrutiva dos membros inferiores de etiologia aterosclerótica cuja única manifestação clínica era dor tipo claudicação intermitente. A idade média foi de 65 anos (33-89 anos). Havia 117 homens (68.8%) com idade média de 65.6 anos (33-84 anos) e 53 mulheres (31.1%) com idade média de 63.7 anos (35-89 anos). RESULTADOS: A síndrome metabólica foi diagnosticada em 98 pacientes (57.6%), 62 homens (63.3%) e 36 mulheres (36.7%). A idade média dos pacientes com síndrome metabólica foi de 63.5 anos, contra 67.0 anos dos pacientes sem síndrome metabólica (P = .027). Considerando os doentes com 65 anos, a síndrome metabólica esteve presente em 46 (48.9%) indivíduos e em 52 (68.4%) pacientes abaixo de 65 anos (P = .011). CONCLUSÕES: A Síndrome Metabólica é uma comorbidade frequente em indivíduos com claudicação intermitente, com prevalência significativamente mais elevada em indivíduos com idade inferior a 65 anos. Não houve associação entre a Síndrome Metabólica e o sexo dos pacientes com claudicação intermitente. Não houve também relação entre a Síndrome metabólica e doença coronariana sintomática na população estudada. A Síndrome Metabólica não afetou nenhum segmento anatômico arterial preferencialmente nos claudicantes / INTRODUCTION: The metabolic syndrome consists in a group of cardiovascular risk factors referring to insulin resistance, associated with increased cardiovascular morbidity and mortality. Metabolic syndrome is correlated to several illnesses, especially those associated with atherosclerosis, like peripheral arterial disease. Intermittent claudication is a symptom of an early stage of peripheral arterial disease, and the precocious diagnosis of metabolic syndrome is important for adequate medical treatment, in order to prevent or delay the progression of atherosclerosis. OBJECTIVES: The aim of this cross-sectional study is to determine the prevalence of the metabolic syndrome in patients with intermittent claudication and its correlation with age, gender, localization of arterial obstruction and association with symptomatic coronary artery disease. METHODS AND RESULTS: There were studied 170 consecutive patients with intermittent claudication, determined by physical examination, which revealed absence or weakness of pulses on the limb or limbs that were limiting deambulation, and an ankle-brachial index 0.9. The mean age was 65 years (33-89 years). There were 117 men (68.8%) with mean age of 65.6 years (33 84 years) and 53 women (31.1%) with mean age of 63.7 years (35 89 years). Metabolic syndrome was diagnosed in 98 patients (57.6%), 62 men (63.3%) and 36 women (36.7%). The mean age of patients with metabolic syndrome was 63.5 years, against 67.0 years of patients without metabolic syndrome (P= .027). Considering patients with 65 years old, the metabolic syndrome was present in 46 (48.9%) individuals and in 52 (68.4%) patients below 65 years old (P= .011). CONCLUSIONS: The metabolic syndrome is frequent among patients with intermittent claudication, with a significant higher prevalence in claudicants < 65 years of age. The metabolic syndrome was not correlated with sex and symptomatic coronary artery disease. The metabolic syndrome did not affect any specific arterial segment in claudicant patients
139

Estenose degenerativa do canal lombar = correlação entre o índice de Oswestry e imagem de ressonância magnética = Degenerative lumbar spinal stenosis: correlation with Oswestry index and magnetic ressonance / Degenerative lumbar spinal stenosis : correlation with Oswestry index and magnetic ressonance

Pasqualini, Wagner, 1960- 21 August 2018 (has links)
Orientador: João Batista de Miranda / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-21T06:02:57Z (GMT). No. of bitstreams: 1 Pasqualini_Wagner_D.pdf: 1157517 bytes, checksum: f927ba791a4b318be74e60bad2138135 (MD5) Previous issue date: 2012 / Resumo: Modelo de Estudo: Estudo diagnóstico Transversal de caso controle. Objetivos: comparar pacientes com estenose do canal lombar com indicação de cirurgia e um grupo controle, assintomáticos para esta doença, levando em consideração imagens de ressonância magnética (RM) e o questionário de Oswestry. Material e Método: Vinte e três pacientes com estenose do canal lombar foram comparados com um grupo controle de 17 indivíduos. Todos foram submetidos a RM e responderam ao questionário de Oswestry. Medidas qualitativas foram descritas segundo os grupos com uso de frequências absolutas e relativas e, verificada a existência de associação dessas medidas com uso do teste exato de Fisher. Medidas quantitativas foram descritas e comparadas entre os grupos com uso do teste Mann-Whitney. O teste de Spearman foi utilizado para avaliar a correlação entre os grupos. Resultados: Lombalgia foi a queixa mais frequente nos dois grupos. O índice de Oswestry mostrou média de percentual de invalidez de 45,69% no Grupo Estenose e 11,60% no Grupo Controle. A RM mostrou que a área de secção transversa do saco dural, o diâmetro do canal e a avaliação dos forames e recesso lateral estavam alterados em ambos os grupos. Conclusões: Não houve relação entre o grau de estenose do canal lombar mensurado em exame de RM com o índice de Oswestry em ambos os grupos / Abstract: Study design: Transversal Case-control, diagnostic study. Objectives: To verify the relationship between the degree of lumbar spinal canal stenosis (LCS), as seen in magnetic resonance imaging (MRI), and the severity of disability as seen in the Oswestry Index, in patients with LCS compared to controls without a diagnosed LCS. Methods: Twenty-three patients with a previous diagnosis of LCS were compared with a control group of 17 volunteers. All participants underwent MRI and answered the Oswestry questionnaire. Qualitative data were described according to the groups with the use of absolute and relative frequencies, and the association of these measures was checked by using the Fisher exact test. Quantitative measures were described and compared between groups using the Mann-Whitney test. Spearman's test was used as well. Results: Low back pain was the most frequent complaint in both groups. The Oswestry index showed average percentage of disability of 45.69% in patients with stenosis and 11.60% in the control group. MRI revealed that the dural sac cross-sectional area (DCSA), the diameter of the canal and the evaluation of lateral recesses and foramina were equally changed in both groups. Conclusions: There was no correlation between the degree of lumbar canal stenosis measured on MRI with the Oswestry Disability Index in both groups / Doutorado / Cirurgia / Doutor em Cirurgia
140

Caracterização do processo de desfolhação e da dinâmica de perfilhamento em azevém sob diferentes ofertas de forragem / Characterization of the defoliation process and the tillering dynamics in italian ryegrass under different herbage allowance

Graminho, Larissa Arnhold 19 February 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This study was conducted with the aim of generating information about the tillering process and contribute to the understanding of the defoliation process of Italian ryegrass (Lolium multiflorum Lam) utilized by lambs submitted to different herbage allowances: 6, 8 and 12 kg body weight DM/100 kg. The grazing method was intermittent. Pasture was utilized during 12 days and an accumulated thermal sum of 250 degree-days was the criterion to determine the grazing interval. The experimental design was completely randomized with repeated measures on time, three treatments and two area replication. It was used 35 marked tillers per paddock to determine the intensity and interval of defoliation. Tillering dynamics on the identification and counting of remaining living tiller and new appearance tillers. The intensity of defoliation is greater in 6 and 9% herbage allowances. The interval of defoliation is higher in forage herbage allowance 12%, intermediate in 9% and lower in the 6% offer. The rate appearance, survival and death of tillers, stability index of tillers number are similar for herbage allowances and differ according phenological stages of ryegrass. Different herbage allowances and phenological stages promote variable intensity and interval of defoliation. The advance of phenological stage increases tiller mortality and reduce the interval between defoliation. / Este estudo foi conduzido com o objetivo de gerar informações a respeito do processo de perfilhamento e contribuir com o entendimento do processo de desfolhação do azevém (Lolium multiflorum Lam.) utilizado por cordeiras submetidas a diferentes ofertas de forragem: 6; 8 e 12 kg de MS/100kg de peso corporal. O método de pastejo foi intermitente. O período de ocupação da pastagem foi de 12 dias e o critério para determinar o intervalo entre pastejos foi a soma térmica acumulada de 250 graus-dia. O delineamento experimental foi inteiramente casualizado, com medidas repetidas no tempo, três tratamentos e duas repetições de área. Utilizaram-se 35 perfilhos marcados por parcela para a determinação da intensidade e intervalo de desfolhação. A dinâmica de perfilhamento baseou-se na identificação e na contagem de perfilhos vivos remanescentes e no aparecimento de novos perfilhos. A intensidade de desfolhação foi superior nas ofertas de forragem 6 e 9%. O intervalo de desfolhação foi superior na oferta de forragem 12%, intermediário na oferta 9% e inferior na oferta 6%. As taxas de aparecimento, sobrevivência e mortalidade de perfilhos e o índice de estabilidade da população de perfilhos são similares nas ofertas de forragem e variam em função dos estádios fenológicos do azevém. As diferentes ofertas de forragem e estádios fenológicos promovem intensidade e intervalo de desfolhação variável. O avanço do estádio fenológico aumenta a mortalidade de perfilhos e reduz o intervalo entre desfolhações.

Page generated in 0.0919 seconds