• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 4
  • Tagged with
  • 8
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Percepciones y actitudes frente al rechazo al uso del dispositivo intrauterino T Cu 380A en usuarias del servicio de planificación familiar del Hospital de Huaycán : enero - marzo 2014

Romero Quispe, Sara Elizabeth January 2014 (has links)
Introducción: La T de cobre ofrece anticoncepción a largo plazo, segura y reversible; sin embargo, a pesar de sus ventajas, las estadísticas nacionales y locales muestran que su aceptación y uso va disminuyendo. Objetivos: Identificar las percepciones y actitudes frente al rechazo al uso del dispositivo intrauterino T CU 380A en usuarias del Servicio de Planificación Familiar del Hospital de Huaycán durante Enero-Marzo 2014. Diseño: Estudio observacional, descriptivo, transversal. Lugar: Hospital local de Huaycán. Participantes: Mujeres usuarias del Servicio de Planificación Familiar. Intervenciones: las unidades participantes estuvo conformada por 120 usuarias del Servicio de Planificación Familiar que han aceptado el uso de algún método anticonceptivo excepto la T de cobre, de las cuales 13 mujeres habían sido usuarias de T de cobre y 107 mujeres usuarias de otros métodos. El procesamiento de datos se realizó usando el paquete estadístico SPSS versión 21. Se realizó estadística univariada y para el análisis estadístico no ajustado se empleó estadística bivariada con las pruebas Chi cuadrado. Principales medidas de resultados: percepciones y actitudes frente al rechazo al uso del Dispositivo Intrauterino T CU 380A. Resultados: Se encontró estadísticamente significativos los siguientes mitos: las mujeres nulíparas o con antecedente de embarazo ectópico no deberían usar la T de cobre (p=0.00), la T de cobre causa cáncer de cuello uterino (p=0.032) y los hilos de la T de cobre incomodan a la pareja durante el acto sexual (p=0.001). Se encontraron estadísticamente significativas las siguientes percepciones: el proveedor de salud no brinda información suficiente del dispositivo intrauterino (p=0.017), no incluye el dispositivo intrauterino en la consejería (p=0.012) y no dispone de tiempo suficiente para dar consejería (p=0.007). Se encontraron estadísticamente significativas las siguientes actitudes: para la utilización de algún método de planificación familiar, interfiere la decisión de la pareja (p=0.033), algún familiar o amigo(a) (p=0.006), la sugerencia del proveedor de salud (p=0.00); la aceptación de la religión al uso del dispositivo intrauterino se relaciona con el rechazo al uso por la usuaria (p=0.001). Conclusiones: Los mitos aún prevalecen en la población femenina tales como la restricción del uso del dispositivo intrauterino en nulíparas o con antecedente de embarazo ectópico, el efecto cancerígeno y la incomodidad de los hilos del dispositivo durante el acto sexual. La atención del proveedor de salud que provoca rechazo al uso: no se brinda información suficiente, no hay inclusión del dispositivo intrauterino en la consejería y se dispone el tiempo suficiente para la consejería de la T de cobre. Las actitudes que provocan rechazo al uso son: Interferencia de la pareja, de algún familiar y/o amiga o del proveedor de salud para decidir el método anticonceptivo a usar; además la aceptación de la religión no influye en la actitud de las usuarias que rechazan la T de cobre.
2

Factores asociados al uso del DIU como método anticonceptivo en usuarias del servicio de planificacion familiar del Centro de Salud Callao. Enero-Diciembre 2009

Villanueva Guzman, Luis Miguel January 2010 (has links)
El presente trabajo tuvo como objetivo identificar cuales eran los factores demográficos, socio-económicos, psicológicos, de información, sexuales y reproductivos asociados al uso del Dispositivo Intrauterino (DIU) en mujeres de 15 a 49 años que acuden al servicio de Planificación Familiar del C.S. Callao y se les fue colocado el DIU, entre los meses de enero y diciembre del año 2009. Se aplicó una encuesta sobre el uso del DIU a 108 mujeres. El análisis cuantitativo de las variables incluyo un análisis descriptivo (distribución de frecuencias) y un análisis inferencial (técnica estadística no paramétrica del chi cuadrado). Como resultado se obtuvo que el DIU fue utilizado por adolescentes en un 3.7%. El estado civil predominante fue el conviviente con un 69.4% y la mayoría procedía de la costa (89.8%). Las usuarias del DIU son en un 3.7% de educación primaria; 83.3% con educación secundaria y 13% con educación superior. Las tres cuartas partes son amas de casa (75%) y las restantes se desempeñan como obreras, empleadas o comerciantes (25%). Con respecto al estrato social, el 66.7% pertenece al Estrato III. La mayoría de usuarias (42.6%) no tenia decidido escoger el DIU como método anticonceptivo al momento de llegar a la consulta, el 18.5% si lo tenia decidido y el 38.9% de las usuarias estaban indecisas. El total de usuarias recibió información sobre Planificación Familiar por la Obstetriz del centro de salud. En el campo sexual y reproductivo, el 34.3% tuvo su primer embarazo en la adolescencia; el numero de hijos vivos es de tres en el 39.8% de usuarias, de dos en el 24.1% y de cuatro en 16.7%; el 48.1% considera que el número ideal de hijos es tres, el 44.4% considera que el número ideal es dos. Ninguna tuvo antecedente de embarazo ectópico; el 26.9% tuvo antecedente de flujo vaginal y el 2.8% tuvo antecedente de ITS. Poco más de la mitad (54.6%) inicio sus relaciones sexuales en la adolescencia. La mitad de las usuarias del DIU (50.9%) uso antes el inyectable y el 37% uso las píldoras combinadas. De la totalidad de usuarias, el 33.3% abandonó el método anticonceptivo previo al DIU por los efectos secundarios. Existe asociación estadísticamente significativa entre la edad del primer embarazo y el estrato social con un p=0.000 a su vez también se encuentra asociación entre la calificación que le da la usuaria al DIU y la motivación que tenia esta por usarlo con un p=0.041. Se concluye que el factor sexual y reproductivo esta asociado al uso del DIU como método anticonceptivo en mayor medida respecto a los demás factores, encontrándose asociaciones estadísticamente significativas entre el ideal reproductivo y el número de hijos vivos, entre la edad del primer embarazo y el estrato social, entre el ideal reproductivo y el grado de instrucción. / Tesis
3

Influencia de una intervención educativa basada en video sobre el dispositivo intrauterino TCu 380A en los conocimientos y actitudes de las puérperas del servicio “E” del Instituto Nacional Materno Perinatal, abril 2016

Torres Montañez, Brenda Desiree January 2016 (has links)
Determina la influencia de una intervención educativa basada en video sobre el dispositivo intrauterino TCu 380A en los conocimientos y actitudes de las puérperas del servicio “E” del Instituto Nacional Materno Perinatal en el mes de Abril del 2016. Es un estudio cuasi-experimental, prospectivo de corte longitudinal, con un grupo experimental y un grupo control. Utiliza una muestra de 100 puérperas del servicio “E” de 20 a 44 años. Emplea una base de datos en Microsoft Excel 2013 y el Programa SPSS versión 15.0. Estima frecuencias absolutas y porcentajes para el análisis de variables cualitativas y la prueba de McNemar para la significancia estadística. Utiliza la prueba Q de Cochran para la contrastación de la hipótesis de la investigación. Encuentra que la mayoría se halla entre los 28-35 años (48% control; 60% experimental); de estado civil, convivientes; de ocupación, ama de casa; con grado de instrucción, secundaria; y procedentes del distrito de San Juan de Lurigancho. Respecto a los conocimientos, se obtiene 100% de desaprobados antes de la intervención basada en video, 10% al final de la intervención y 22% a la semana de culminación. Respecto a las actitudes, el 100% presenta una actitud desfavorable antes de la intervención basada en video, 30% al final de la intervención y 28% a la semana de culminación. El análisis por medio de la Prueba Q de Cochran determina que la intervención educativa basada en video sí influye positivamente en los conocimientos y actitudes de las puérperas. Los resultados fueron estadísticamente significativos p <0.05. Concluye que la intervención educativa basada en video influye positivamente sobre los conocimientos y actitudes frente al dispositivo intrauterino de las puérperas del servicio “E” del Instituto Nacional Materno Perinatal en el mes de Abril del 2016.
4

Efecto de una intervención educativa sobre conocimientos, actitudes y prácticas en el uso del dispositivo intrauterino

Huamani Chipana, Sandra Sofia January 2018 (has links)
Publicación a texto completo no autorizada por el autor / Demuestra el efecto de una intervención educativa sobre conocimientos, actitudes y prácticas en el uso del dispositivo intrauterino en usuarias del servicio de planificación familiar del Hospital San Juan De Lurigancho, 2018. Realiza un estudio cuasi-experimental donde se estudió una muestra no probabilística obtenida por conveniencia de 90 usuarias del servicio de planificación familiar. Todas recibieron intervención educativa sobre el dispositivo intrauterino 380 A que brinda el Hospital San Juan de Lurigancho por aproximadamente 40 minutos. Pre y post intervención, las usuarias respondieron a los cuestionarios sobre conocimientos, actitudes y prácticas en el uso de dicho dispositivo. Encuentra que la edad promedio de las usuarias de PF fue de 29 años, el 73.3% fue entre 20 y 34 años, el 87.8% convivientes, el 58.9% con educación secundaria, el 92.2% procedente del distrito de San Juan de Lurigancho y el 44.4% tenía 2 hijos. Los anticonceptivos más conocidos y más usados fueron el preservativo y el inyectable. Previa a la intervención educativa, el nivel de conocimiento sobre el dispositivo intrauterino era bajo con un 68.9%, las actitudes eran de indiferentes 74.4% a desfavorables 18.9%, y sólo el 14.4% usaría el DIU de cobre como anticonceptivo. Posterior a la intervención, el nivel de conocimiento era alto 57.8%, las actitudes fueron de indiferentes 64.4% a favorables 35.6%, y ahora el 24.4% usaría el DIU de cobre. Concluye que la intervención educativa sobre el dispositivo intrauterino 380 A tuvo un efecto positivo en las usuarias del servicio de planificación familiar del Hospital San Juan De Lurigancho, dado que mejoró su nivel de conocimiento, actitudes y prácticas. / Tesis
5

Avaliação da dificuldade técnica e dor na inserção de sistema intrauterino liberador de levonorgestrel : Evaluation of pain and technical difficulties at insertion of the levonorgestrel-releasing intrauterine system / Evaluation of pain and technical difficulties at insertion of the levonorgestrel-releasing intrauterine system

Santos, Ana Raquel Gouvêa, 1980- 08 January 2012 (has links)
Orientador: Ilza Maria Urbano Monteiro / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-20T19:58:08Z (GMT). No. of bitstreams: 1 Santos_AnaRaquelGouvea_M.pdf: 962766 bytes, checksum: e715593c7f98a14aacfd9c4d956e7c8d (MD5) Previous issue date: 2012 / Resumo: Introdução: A anticoncepção intrauterina é um método bastante eficiente, porém sub-utilizada. Uma das causas que diminuem seu uso são as dificuldades que o profissional enfrenta no momento da inserção bem como a dor que a paciente sente durante o procedimento. Recentemente o sistema intrauterino liberador de levonorgestrel (SIU-LNG) foi introduzido como uma nova opção de dispositivo intrauterino com características que ampliaram a indicação e uso do mesmo. A introdução do SIU-LNG retomou a discussão sobre seu uso em cada vez mais mulheres inclusive nas nunca engravidaram. Objetivo: Identificar e comparar as dificuldades técnicas na inserção do SIU-LNG e o grau de dor referida entre nuligestas e multíparas com e sem cesárea anterior. Métodos: Setenta e quatro mulheres que procuraram o serviço de planejamento familiar do CAISM/UNICAMP para primeira colocação de SIU - LNG como método anticoncepcional (MAC) foram incluídas no estudo, de Maio a Dezembro de 2011. As mulheres foram divididas em três grupos: 23 nuligestas, 28 multíparas com antecedente de cesárea e 23 sem antecedente de cesárea. Após serem submetidas à inserção do SIU-LNG foi pedido que classificassem a dor segundo a Escala Visual Analógica (EVA) de 0 (sem dor) a 10 (maior dor possível). No retorno, entre 45 e 60 dias após a inserção, foram questionadas novamente sobre a dor que sentiram no dia da inserção segundo o mesmo score. O profissional responsável pela inserção classificou a inserção em fácil, com dificuldade esperada, mais difícil que o esperado ou impossível de realizar inserção. O mesmo também classificou a causa da dificuldade encontrada em: estenose cervical, irregularidade da cavidade uterina, dor da paciente, reação vagal. Foi realizada uma análise de comparação de médias entre os três grupos sobre a dor e de características clínicas que poderiam estar associadas com a mesma. Grau de significância 5% com poder do teste de 80%. Resultados: Todas as mulheres referiram dor no momento da inserção. Não houve diferença nas médias de dor de acordo com paridade ou via de parto. Não houve diferença também quando classificamos a dor em leve, moderada ou severa. Apesar da dor, 93% das mulheres referiram que submeteriam-se novamente a inserção do SIU-LNG tanto no momento da inserção como um mês após. A média de dor referida após um mês foi semelhante entre os grupos e não foi significativamente menor do que imediatamente após a inserção. Nas nuligestas o tipo de dificuldade mais encontrada foi estenose cervical, nas multíparas com cesárea anterior foi irregularidade da cavidade uterina e nas multíparas sem cesárea anterior foi dor da paciente no momento da inserção. Não houve maior dificuldade de inserção em nenhum dos grupos. Não houve associação de algum dos tipos de dificuldade com maiores média de dor. Conclusões: Todas as mulheres independente da paridade ou via e parto referiram dor no momento da inserção do SIU-LNG. A dor não consistiu em um empecilho para a escolha do SIU-LNG. A principal causa de dificuldade variou de acordo com a paridade. A inserção do SIU-LNG é possível para todos os grupos de pacientes / Abstract: Background: Despite the high contraceptive effectiveness and non-contraceptive benefits there are still concerns of use of the levonorgestrel-releasing intrauterine system (LNG-IUS) in nulligravida women. Objective: Evaluate ease of insertion and cause of difficulty by health proffessionals and women pain at insertion of the LNG-IUS in nulligravida women compared to parous women with and without cesarean section (C-section). Methods: Three groups were constituted: one with 23 nulligravida women, one with 28 parous women with previous cesarean and one with 23 parous women without previous C-section who received an LNG-IUS. The pain at insertion was evaluated immediately after insertion on the Visual Analogic Scale (VAS). On the second visit after one month women were asked again about the pain at insertion according to the VAS. The ease of insertion was evaluated as easy or difficult and was classified by the health professional according to cause (cervical stenosis, uterine irregularity, pain) after insertion. Results: Almost all patients reported pain at insertion, independent of parity and delivery. Despite reporting pain about 93% of the women would submit themselves to LNG-IUS insertion once again if necessary. In the followup control there was no diference, as well in the pain scores among the groups. In nulligravida the type of difficulty most common was cervical stenosis, in parous women with C-section was uterine cavity irregularity in parous women without C-section was pain. There was no association between type of difficulty and high pain scores. Conclusions: All women reported pain at insertion. Pain at insertion is not a problem for the use of the method among patients. Type of difficulty at insertion is related to parity. There was no difference in difficulty for any group / Mestrado / Fisiopatologia Ginecológica / Mestre em Ciências da Saúde
6

Avaliação e caracterização de dispositivos intrauterinos utilizados comercialmente. / Evaluation and characterization of intrauterine devices used commercially.

BEZERRA, Maria das Neves Guedes Cavalcanti. 16 April 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-16T19:27:36Z No. of bitstreams: 1 MARIA DAS NEVES GUEDES CAVALCANTI BEZERRA - DISSERTAÇÃO PPG-CEMat 2014..pdf: 1961977 bytes, checksum: 48356976ff3729c606e179600ae156ad (MD5) / Made available in DSpace on 2018-04-16T19:27:36Z (GMT). No. of bitstreams: 1 MARIA DAS NEVES GUEDES CAVALCANTI BEZERRA - DISSERTAÇÃO PPG-CEMat 2014..pdf: 1961977 bytes, checksum: 48356976ff3729c606e179600ae156ad (MD5) Previous issue date: 2014-05-30 / A pesquisa teve como objetivo realizar análise comparativa entre os contraceptivos DIU`s utilizados comercialmente. Dentro desse objetivo buscou-se: propor bases comparativas entre composição dos DIU TCu 380 A e endoceptivos hormonais; determinar a possível oxidação dos DIU‟s de Cobre; determinar o tipo de polietileno utilizado em ambos os DIU‟s. A pesquisa foi desenvolvida no Laboratório de Avaliação e Desenvolvimento de Biomateriais do Nordeste - CERTBIO, localizada na Unidade Acadêmica de Engenharia de Materiais, na Universidade Federal de Campina Grande/UFCG. Foram utilizadas duas amostras de Dispositivos Intrauterinos usualmente utilizados, descritos adiante: DIU TCu 380 A e Endoceptivo Medicamentos. Foram avaliadas as composições químicas dos DIU‟s e o tipo de polietileno, através das seguintes técnicas: Microscopia Óptica (MO), Microscopia Eletrônica de Varredura (MEV/EDX), Espectroscopia na Região de Infravermelho com Transformada de Fourier (FTIR), Difração de Raios X (DRX) e Calorimetria Exploratória Diferencial (DSC). Pode-se comprovar também a partir da análise de EDS a presença do sulfato de bário em ambos os DIU‟s, onde o mesmo é utilizado para tornar o DIU visível em raios X. Comprovou-se a presença de silício e oxigênio no tronco do DIU com levonorgestrel indicando ser o mesmo constituído por uma polidimetilsiloxano como informado pelo fabricante. Pode-se comprovar pela análise de FTIR, que o material formador dos corpos principais de ambos os DIU‟s era polietileno pela análise do espectograma. A análise de DRX corroborou com os resultados obtidos na análise de FTIR, que indicavam que o material dos dispositivos se tratava de polietileno, apresentando um espectograma típico de PE. Pode-se comprovar também, que o fio e os anéis do DIU TCu 380 A eram compostos por cobre. A análise de DSC mostrou ser o polietileno constituinte de ambos os DIU‟s, um polietileno de baixa densidade (LDPE). Diante do exposto podese concluir que ambos os DIU‟s possuem corpo formado por polietileno de baixa densidade, porém, possuem processamentos diferentes, onde a estrutura do DIU levonorgestrel apresenta superfície com acabamento mais refinado em relação ao DIU TCu 380 A. / The research aims to perform comparative analysis between contraceptives - IUD`s used commercially. Within this objective we sought: to propose a comparative basis between composition of TCu 380A IUD and Hormonal Endoception; determine the possible oxidation of copper IUDs; determining the type of polyethylene used in both IUD's. The research was conducted at the Laboratory of Biomaterials Evaluation and Development of the Northeast - CERTBIO, located in the Academic Unit of Materials Engineering, Federal University of Campina Grande / UFCG. TCu 380A and Sterile Endoception: two samples of intrauterine devices commonly used, as described below were used. Chemical compositions of IUDs and type of polyethylene were evaluated using the following techniques: Optical Microscopy (OM), Scanning Electron Microscopy (SEM / EDX) Spectroscopy in the Region with Infrared Fourier Transform Spectroscopy (FTIR), X-Ray Diffraction (XRD) and Differential Scanning Calorimetry (DSC). It can also prove from the EDS analysis the presence of barium sulphate in both IUD's, where it was used to make the IUD visible on x-rays proved the presence of silicium and oxygen in the stem of the IUD levonorgestrel indicating that it comprises a polydimethylsiloxane as reported by the manufacturer. Can be proved with FTIR analysis of the forming material of the principal of both bodies was polyethylene IUD‟s for examining the spectrogram. XRD analysis corroborated the results obtained with FTIR analysis of the material indicated that the devices it was polyethylene having a typical PE spectrogram. One can also show that the wire rings and the TCu 380 were composed of copper. The DSC analysis showed to be a constituent of both polyethylene IUDs Low Density Polyethylene (LDPE). Given the above it can be concluded that both IUDs have bodies formed of low density polyethylene, but have different processing, where the structure of the IUD levonorgestrel has finer surface finish compared to TCu 380 A.
7

Conhecimento, atitudes e práticas de mulheres usuárias de unidades básicas de saúde da cidade de São Paulo sobre o dispositivo intrauterino / Knowledge, attitude and practices of women users of primary health facilities of Sao Paulo City about intrauterine device

Araújo, Karina Simão 08 June 2017 (has links)
Introdução: No Brasil, o uso de métodos contraceptivos está centrado na pílula anticoncepcional oral, na laqueadura e na camisinha masculina. Métodos contraceptivos reversíveis de longa duração, como o dispositivo intrauterino, são pouco usados, ao contrário do que ocorre no contexto internacional. A literatura mostra que há várias razões para essa subutilização, dentre as quais destaca-se o escasso conhecimento das mulheres sobre o mesmo que, por sua vez, promove atitudes negativas e concepções equivocadas em relação ao método e dificulta que as mulheres optem por ele. Objetivo: Analisar o conhecimento, as atitudes e as práticas de mulheres usuárias de Unidades Básicas de Saúde sobre o dispositivo intrauterino. Método: Estudo quantitativo transversal, em que amostra probabilística de 1.026 mulheres, de 18 a 49 anos de idade, usuárias de 38 Unidades Básicas de Saúde da cidade de São Paulo, foi entrevistada por meio de um instrumento estruturado. O nível de conhecimento sobre o método foi analisado por meio de uma escala composta por sete itens, preparada por meio Teoria de Resposta ao Item e análise fatorial. As atitudes foram analisadas em função das razões relatadas pelas mulheres para usar/não usar o DIU. As práticas foram analisadas considerando o uso anterior e o uso atual. Modelos de regressão logística múltipla foram conduzidos para identificar as características sociodemográficas e da história reprodutiva associadas ao conhecimento, uso e desejo de usar o dispositivo intrauterino. Resultados: Apenas 4,5% das mulheres alcançaram o escore máximo da escala do nível de conhecimento, ao passo que 13,1% obtiveram escore zero. As mulheres mais escolarizadas, de grupo socioeconômico mais elevado, que possuíam mais de um filho e que usavam ou já haviam usado o dispositivo intrauterino mostraram maior nível de conhecimento. A maioria das entrevistadas referiu não ter o desejo de usar o dispositivo intrauterino no futuro, principalmente porque estavam satisfeitas com o método em uso e por conta dos efeitos colaterais, tal e qual mulheres que nunca usaram o método. Aquelas que usavam, que já haviam usado e que gostariam de usar o dispositivo intrauterino apresentaram maior nível de conhecimento sobre o mesmo. Conclusão: O nível de conhecimento sobre o dispositivo intrauterino é baixo e influencia as atitudes e as práticas das mulheres. Aparentemente, conhecimento, atitudes e práticas sobre o dispositivo uterino são interconectados. / Introduction: In Brazil, the use of contraceptive methods is focused on the oral pill, tubal ligation and male condom. Different from the international context, long-term reversible contraceptive methods, such as the intrauterine device, are rarely used. According to the literature, there are several reasons for this underutilization, among them, stands out the lack of women´s knowledge, which in turn promotes negative attitudes and misconceptions about the method and, consequently, makes the choose to use it more difficult. Objective: To analyze the knowledge, attitudes and practices of women users of primary health care facilities about the intrauterine device. Method: A cross-sectional quantitative study was conducted among a probability sample of 1,026 women aged 1849, who were users of 38 primary health care facilities of Sao Paulo City. All participants were interviewed through a structured instrument. The level of knowledge about the method was analyzed through a seven-item scale, developed through Item Response Theory and factorial analysis. The attitudes were analyzed according to the reasons reported by the women to use/not to use the intrauterine device. The practices were analyzed considering the previous use and the current use. Multiple logistic regression models were conducted to identify sociodemographic and reproductive history characteristics associated with the knowledge, use, and desire to use the intrauterine device. Results: Only 4,5% of the women achieved the maximum score on the knowledge level scale, while 13,1% scored zero. Women with more educational level, belonging to higher socioeconomic group, who had more than one child, and who used or had already used the intrauterine device showed a higher level of knowledge. Most of the interviewees reported not having the desire to use the IUD in the future, mainly because they were satisfied with the contraceptive method in use and because of the side effects; similar to women who never used the method. Those who used, who had already used and would like to use the intrauterine device had a higher level of knowledge about it. Conclusion: The level of knowledge about the intrauterine device is low and influences women\'s attitudes and practices. Apparently, knowledge, attitudes and practices about the uterine device are interconnected.
8

Conhecimento, atitudes e práticas de mulheres usuárias de unidades básicas de saúde da cidade de São Paulo sobre o dispositivo intrauterino / Knowledge, attitude and practices of women users of primary health facilities of Sao Paulo City about intrauterine device

Karina Simão Araújo 08 June 2017 (has links)
Introdução: No Brasil, o uso de métodos contraceptivos está centrado na pílula anticoncepcional oral, na laqueadura e na camisinha masculina. Métodos contraceptivos reversíveis de longa duração, como o dispositivo intrauterino, são pouco usados, ao contrário do que ocorre no contexto internacional. A literatura mostra que há várias razões para essa subutilização, dentre as quais destaca-se o escasso conhecimento das mulheres sobre o mesmo que, por sua vez, promove atitudes negativas e concepções equivocadas em relação ao método e dificulta que as mulheres optem por ele. Objetivo: Analisar o conhecimento, as atitudes e as práticas de mulheres usuárias de Unidades Básicas de Saúde sobre o dispositivo intrauterino. Método: Estudo quantitativo transversal, em que amostra probabilística de 1.026 mulheres, de 18 a 49 anos de idade, usuárias de 38 Unidades Básicas de Saúde da cidade de São Paulo, foi entrevistada por meio de um instrumento estruturado. O nível de conhecimento sobre o método foi analisado por meio de uma escala composta por sete itens, preparada por meio Teoria de Resposta ao Item e análise fatorial. As atitudes foram analisadas em função das razões relatadas pelas mulheres para usar/não usar o DIU. As práticas foram analisadas considerando o uso anterior e o uso atual. Modelos de regressão logística múltipla foram conduzidos para identificar as características sociodemográficas e da história reprodutiva associadas ao conhecimento, uso e desejo de usar o dispositivo intrauterino. Resultados: Apenas 4,5% das mulheres alcançaram o escore máximo da escala do nível de conhecimento, ao passo que 13,1% obtiveram escore zero. As mulheres mais escolarizadas, de grupo socioeconômico mais elevado, que possuíam mais de um filho e que usavam ou já haviam usado o dispositivo intrauterino mostraram maior nível de conhecimento. A maioria das entrevistadas referiu não ter o desejo de usar o dispositivo intrauterino no futuro, principalmente porque estavam satisfeitas com o método em uso e por conta dos efeitos colaterais, tal e qual mulheres que nunca usaram o método. Aquelas que usavam, que já haviam usado e que gostariam de usar o dispositivo intrauterino apresentaram maior nível de conhecimento sobre o mesmo. Conclusão: O nível de conhecimento sobre o dispositivo intrauterino é baixo e influencia as atitudes e as práticas das mulheres. Aparentemente, conhecimento, atitudes e práticas sobre o dispositivo uterino são interconectados. / Introduction: In Brazil, the use of contraceptive methods is focused on the oral pill, tubal ligation and male condom. Different from the international context, long-term reversible contraceptive methods, such as the intrauterine device, are rarely used. According to the literature, there are several reasons for this underutilization, among them, stands out the lack of women´s knowledge, which in turn promotes negative attitudes and misconceptions about the method and, consequently, makes the choose to use it more difficult. Objective: To analyze the knowledge, attitudes and practices of women users of primary health care facilities about the intrauterine device. Method: A cross-sectional quantitative study was conducted among a probability sample of 1,026 women aged 1849, who were users of 38 primary health care facilities of Sao Paulo City. All participants were interviewed through a structured instrument. The level of knowledge about the method was analyzed through a seven-item scale, developed through Item Response Theory and factorial analysis. The attitudes were analyzed according to the reasons reported by the women to use/not to use the intrauterine device. The practices were analyzed considering the previous use and the current use. Multiple logistic regression models were conducted to identify sociodemographic and reproductive history characteristics associated with the knowledge, use, and desire to use the intrauterine device. Results: Only 4,5% of the women achieved the maximum score on the knowledge level scale, while 13,1% scored zero. Women with more educational level, belonging to higher socioeconomic group, who had more than one child, and who used or had already used the intrauterine device showed a higher level of knowledge. Most of the interviewees reported not having the desire to use the IUD in the future, mainly because they were satisfied with the contraceptive method in use and because of the side effects; similar to women who never used the method. Those who used, who had already used and would like to use the intrauterine device had a higher level of knowledge about it. Conclusion: The level of knowledge about the intrauterine device is low and influences women\'s attitudes and practices. Apparently, knowledge, attitudes and practices about the uterine device are interconnected.

Page generated in 0.0603 seconds