• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 165
  • 149
  • 64
  • 29
  • 23
  • 10
  • 8
  • 6
  • 6
  • 6
  • 5
  • 5
  • 3
  • 3
  • 2
  • Tagged with
  • 526
  • 43
  • 40
  • 37
  • 35
  • 33
  • 26
  • 25
  • 24
  • 22
  • 21
  • 21
  • 19
  • 19
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

UM ESPECTROMETRO \"MINI-ORANGE\" PARA ELECTRONS / A mini-orange spectrometer for electrons

Nelson Canzian da Silva 04 May 1990 (has links)
Foi projetado e construído um espectrômetro Mini-Orange (MO) para eléctrons, utilizando imãs planos permanentes e um detector de barreira de superfície. Foram determinadas as funções de transmissão de diferentes configurações do sistema, para energias entre 200-1100 keV. Foi desenvolvido um modelo matemático do sistema, a partir de solução analítica para o campo de um imã plano e da integração numérica da equação de movimento dos eléctrons no campo de MO. As funções de transmissão assim obtidas foram comparadas aos resultados experimentais e mostraram um bom acordo para energias baixas e intermediárias. / A Mini-Orange spectrometer for electrons was designed and built, using plane permanent magnets and a surface barrier detector. Transmission functions were obtained for various system configurations and for energies between 200-1100 keV. A mathematical model of the system was developed, using the analytical solution for the field of a plane magnet and the numerical integration of the equation of motion of the electrons in the MO magnetic field. The calculated transmission functions were compared to the experimental data, showing a good agreement for low and intermediate energies.
62

Caractérisation de l’interaction des protéines IMA/MIF2 et CSN5 au niveau moléculaire et physiologique

Leblond-Castaing, Julie 19 December 2011 (has links)
Les plantes ont la capacité à former de nouveaux organes grâce à une croissance continue assurée par une réserve de cellules souches au sein de structures spécifiques, les méristèmes. Les méristèmes floraux diffèrent des méristèmes végétatifs par leur caractère déterminé aboutissant à la production des fleurs. Le gène IMA (INHIBITOR OF MERISTEM ACTIVITY) code une protéine contenant un motif «doigt à zinc» (MIF) régulant les processus développementaux de la fleur et des ovules chez la tomate. En effet, IMA inhibe la prolifération cellulaire au cours de la terminaison florale en agissant sur l’expression du gène WUSCHEL, responsable du maintien du pool de cellules souches et contrôle le nombre de carpelles (Sicard et al., 2008). De plus, les protéines IMA et son orthologue chez Arabidopsis, MIF2, modulent la réponse à certaines phytohormones. De manière identique à la protéine MIF1 (Hu and Ma, 2006), IMA/MIF2 régule négativement la réponse aux brassinostéroïdes, à l’auxine, aux cytokinines et aux gibbérellines mais positivement la réponse à l’acide abscissique suggérant une fonction commune des protéines MIF dans les voies de réponse aux phytohormones. Un criblage d’une banque d’ADNc par la technique de double hybride a permis de révéler l’interaction entre les protéines IMA/MIF2 et une sous-unité du complexe signalosome, CSN5. De façon intéressante, les plantes mutantes csn5 d’Arabidopsis montrent de nombreuses altérations phénotypiques telles qu’un aspect buissonnant résultant de la perte de la dominance apicale, et une altération de la réponse à l’obscurité et à l’auxine. Ces phénotypes sont fortement ressemblants aux phénotypes des plantes MIF1OE d’Arabidopsis (Hu and Ma, 2006) et des plantes IMAOE de tomate (Sicard et al., 2008). Les résultats obtenus au cours de ce projet montrent que la protéine IMA inhibe la fonction du complexe signalosome grâce à son interaction avec la protéine CSN5. / Plants have the ability to form new organs as a result of indeterminate growth ensured by specific regions of pluripotent cells, called meristems. Flowers are produced by the activity of floral meristems which differ from vegetative meristems in their determinate fate. The INHIBITOR OF MERISTEM ACTIVITY (IMA) gene encoding a Mini Zinc Finger (MIF) protein from tomato (Solanum lycopersicum) regulates the processes of flower and ovule development. IMA inhibits cell proliferation during floral termination, controls the number of carpels during floral development and acts as a repressor of the meristem organizing centre gene WUSCHEL (Sicard et al., 2008). We demonstrated that IMA and its Arabidopsis ortholog MIF2 is also involved in a multiple hormonal signalling pathway, as a putative conserved feature for plant MIF proteins (Hu and Ma, 2006). Alike Arabidopsis MIF1, IMA/MIF2 regulates negatively BR, auxin, cytokinin and gibberellin signalling and positively ABA signaling. Using yeast two-hybrid screening experiments, we identified a strong protein-protein interaction between IMA and the signalosome subunit 5 (CSN5). Interestingly the csn5 mutant in Arabidopsis displays pleiotropic developmental defects such as a bushy phenotype originating from the loss of apical dominance and the alteration in sensitivity to darkness and auxin signals. These phenotypes are strikingly similar to what was described for Arabidopsis MIF1 (Hu and Ma, 2006) and tomato IMA overexpressors plants (Sicard et al., 2008), respectively. Taken together our data strongly suggest that IMA may act as an inhibitor of CSN function through its physical interaction with SlCSN5. The observed converse effects of IMA/MIF2 overexpression or deregulation on plant development and the abundance of developmental marker genes further support the notion of a CSN inhibitory control, since the COP9 signalosome through the specific deneddylation activity of the CSN5 subunit regulates plant hormone signalling.
63

Passive cooling of data centers : modeling and experimentation / Refroidissement passif des datas centers : modélisation et expérimentation

Nadjahi, Chayan 17 December 2018 (has links)
L'objectif de cette étude est de concevoir un système de refroidissement passif au sein d'un data center. La solution qui a été choisie est la boucle thermosiphon, combinant le free cooling et le refroidissement par changement de phase. Cette technologie offre de la simplicité et de la compacité. De plus, en l'associant avec des échangeurs de chaleur à micro-canaux, elle est capable d'absorber de grandes quantités de flux de chaleur avec un faible débit du réfrigérant. La boucle thermosiphon est composée d'un évaporateur à mini-canaux et à courants parallèles, d'un condenseur à air, d'un riser et d'un downcomer. Un prototype expérimental a été construit afin de caractériser les transferts de chaleur entre le réfrigérant et la chaleur créée. Des études expérimentales sont introduites. L'influence du taux de chargement et de la puissance électrique est détaillée et analysée. En parallèle, un modèle numérique a été développé pour prédire les caractéristiques du réfrigérant en fonction des paramètres géométriques et climatiques. Une comparaison avec les résultats expérimentaux est également effectuée. Enfin, la boucle thermosiphon est améliorée avec l'ajout d'un second évaporateur. Les tests sont effectués avec des puissances plus importantes. Une nouvelle conception d'une boucle thermosiphon et les limites du prototype sont présentées. / The objective of this study is to build a passive cooling system in a data center. The chosen solution is the loop thermosyphon, combining free cooling and two-phase cooling. This technology offers simplicity and compactness. Furthermore, by associating with micro-channels heat exchangers, it is able to remove higher heat fluxes while working with smaller mass flow rate of coolant. The thermosyphon is composed by mini-channel parallel-flow evaporator, an air condenser, a riser and a downcomer. The experimental setup has been built to characterize the heat transfer between the working fluid and the provided heat. An experimental study is introduced. The effect of the fill ratio and the input power is specified and analyzed. In parallel, a numerical model has been developed to predict the fluid properties in function of geometrical and climatic parameters. A comparison between experimental and numerical results is also carried out. Finally, the loop thermosyphon is upgraded with a second mini-channel parallel flow evaporator. Tests are conducted with huger heat flux. A new design of loop thermosyphon and the limits of the prototype are introduced.
64

Real-time tracking of deformable targets in 3D ultrasound sequences / Suivi temps-réel de cibles dans des séquences de volumes échographiques

Royer, Lucas 06 December 2016 (has links)
De nos jours, les traitements mini-invasifs, tels que l'ablation par radiofréquence, sont de plus en plus utilisés car ils permettent d'éliminer localement les tumeurs à partir de l'insertion d'une aiguille. Cependant, le succès de ces procédures dépend de la précision du positionnement de l'aiguille par rapport aux structures anatomiques. Afin de garantir un placement correct, l'imagerie échographique est souvent utilisée car elle a l'avantage d'être temps-réelle, bas coût, et non-invasive. En revanche, celle modalité peut compliquer la visualisation de certaines structures en raison de sa qualité et de son champ de vue limité. En outre, la précision des interventions peut aussi être perturbée par les déplacements de tissus liés aux mouvements physiologiques du patient et à la manipulation d'instruments médicaux. Afin d'aider le chirurgien à mieux cibler certaines structures anatomiques, de nombreuses équipes de recherche ont proposé des travaux permettant d'estimer la position de régions d'intérêts dans l'imagerie échographique. Cette thèse propose plusieurs contributions permettant de suivre en temps réel des structures déformables dans des séquences d'échographie 3D. Une première contribution repose sur l'utilisation conjointe de l'information visuelle dense et d'une méthode de simulation physique. Dans cette thèse, nous avons aussi proposé un nouveau critère de similarité spécifique à l'imagerie échographique basé sur une étape de détection d'ombres. Enfin, la dernière contribution est liée à une stratégie de suivi hybride permettant d'améliorer la qualité des images. A partir de ces contributions, nous proposons une méthode de suivi robuste au bruit de type« speckle », aux ombres et aux changements d'intensité perturbant l'imagerie échographique. Les performances des différentes contributions sont évaluées à partir de données simulées et de données acquises sur maquettes et sur volontaires humains. Ces résultats montrent que notre méthode est robuste à différents artefacts de l'imagerie échographique. En outre, nous démontrons la performance de notre approche par rapport à différentes méthodes de l'état de l'art sur des bases de données publiques fournies par les challenges MICCAI CLUST'14 et CLUST'15. Dans cette thèse, nous proposons également une application permettant de combiner l'imagerie échographique à l'imagerie par résonance magnétique (IRM). Cette méthode permet d'observer des structures anatomiques non-visibles dans l'imagerie échographique durant l'intervention. Elle est basée sur la combinaison d'une méthode de suivi et d'un recalage multi-modal obtenu à partir d'un système de localisation externe. Cette application a été évaluée sur un volontaire sain à partir d'une plateforme liée au centre Hospitalier Universitaire de Rennes. / Nowadays, mini-invasive treatments, such as radio-frequency ablation, are increasingly being used because they allow eliminating tumors locally from needle insertion. However, the success of these therapies depends on the accurate positioning of the needle with respect to anatomical structures. To ensure correct placement, ultrasound (US) imaging is often used since this system has the advantage to be real-time, low-cost, and non-invasive. However, during the intervention, US imaging can complicate the visualization of targeted structures due to its poor quality and its limited field of view. Furthermore, the accuracy of these interventions may also be perturbed by both physiological movements and medical tools displacements that introduce motions of anatomical structures. To help the surgeon to better target malignant tissues, many research teams have proposed different method in order to estimate the position of regions of interest in ultrasound imaging. This thesis provides several contributions that allow tracking deformable structures in 3D ultrasound sequences. We first present a method that allows providing robust estimation of target positions by combining an intensity-based approach and mechanical model simulation. In this thesis, we also propose novel ultrasound-specific similarity criterion based on prior step that aims at detecting shadows. The last contribution is related to a hybrid tracking strategy that allows improving quality of ultrasound images. From these contributions, we propose a tracking method that has the advantage to be invariant to speckle noise, shadowing and intensity changes that can occur in US imaging. The performance and limitations of the proposed contributions are evaluated through simulated data, phantom data, and real-data obtained from different volunteers. Simulation and phantom results show that our method is robust to several artefacts of US imaging such as shadows and speckle decorrelation. Furthermore, we demonstrate that our approach outperforms state-of-the-art methods on the 3D public databases provided by MICCAI CLUST'14 and CLUST'15 challenges. In this thesis, we also propose an application that combines ultrasound imaging to Magnetic Resonance lmaging (MRI). This method allows observing anatomical structures that are not visible in US imaging during the intervention. It is based on the combination between US tracking method and multi modal registration obtained from external localization system. This application was evaluated on a volunteer thanks to an MRJ imaging platform locate at the University Hospital of Rennes.
65

A Mini-PET beamline for optimized proton delivery to the ISOTRACE™ target system

Dehnel, M. P., Jackle, P., Potkins, D., Stewart, T., Boudreault, G., Jones, T., Philpott, C. January 2015 (has links)
Introduction The ISOTRACE™ Super-Conducting Cyclotron is PMB-Alcen’s redeveloped and modernized version of Oxford Instrument’s OSCAR superconducting cyclotron [1]. Its extracted 80+ mi-croamperes of 12 MeV protons are used for the production of PET radioisotopes. Following the philosophy of Dickie, Stevenson, Szlavik [2] for minimizing dose to personnel, and as developed by Dehnel et al [3,4], and Stokely et al [5], the ISOTRACE™ shall utilize an innovative, light-weight, integrated and self-supporting Mini-Beamline. This permits the relatively high residual radiation fields around PET targets to be moved ~1 metre away from the cyclotron, and facilitates the use of local shielding (around the targets) that limits prompt gammas and neutrons, but more importantly attenuates the residual target radiation, so that maintenance/research staff can work on the cyclotron in a relatively low activity environment. In addition, the mini-beamline for PET utilizes a compound quadrupole/steerer doublet that permits active and dynamic focusing/steering of the extracted proton beam for optimized production and minimized losses [3], so it improves on the successful work of Theroux et al [6]. The integrated beamline unit is extremely small, so that it is very unlike bulky traditional PET and SPECT beamlines that require substantial support structures, such as described by Dehnel in [7,8]. Material and Methods The ISOTRACE™ cyclotron is pictured in FIG. 1. The exit port flange and gate valve to which the integrated mini-beamline for PET shall be mounted is shown. Immediately upstream of the exit port, hidden from view, is a 4 jaw collimator (called BPI for Beam Position Indicator) with spilled beam current readbacks to the control system. TABLE 1 shows the nominal beam emittance and Twiss parameter values at the exit port flange location. This ion-optical information is necessary to simulate ion beam transport, develop the mini-beamline, and determine a nominal tune (i.e. magnet settings). Results and Conclusion TABLE 2 shows the ion-optical system parameters. FIGS. 2 and 3 show the horizontal and vertical beam profiles. The Horizontally focusing Quadrupole magnet (HQ), and Vertically focusing Quadrupole magnet (VQ) aperture diameter, 33 mm, was chosen to give sufficient beam acceptance. The focusing strength is a function of BL, so the effective length, L = 150 mm, was chosen to ensure Bmax less than 0.3 Tesla, while keeping overall magnet mass down. The quad-rupole magnets are fitted with water-cooled compound coils in which the copper/mylar strip wound portion of each coil is a winding for the quadrupole focusing function, and the wire wound portion is for the steering function. To increase beam acceptance and provide additional section strength for the pipe support function, the internal aperture of the low-activation aluminium beam pipe and the external shape are in the shape of a cross. FIG. 4 shows the beam crosssection at the mid-point of the downstream quadrupole magnet, and illustrates the additional acceptance as compared to a round beampipe. In order to machine the interior profile, the pipe is comprised of two premachined pieces that are friction stirwelded together. FIG. 5 is an isometric of the mini-beamline for PET. The four upstream HQ compound coils are excited with a 75A power supply for the horizontally focusing quadrupole magnet function, and a ± 10A power supply for a vertical steering function. The same power supplies are used for the four downstream VQ compound coils for the purpose of a vertically focusing quadrupole magnet function and horizontal steering function.
66

Erhebung der nicht-motorischen Symptome bei Morbus Parkinson: Ergebnisse zweier multizentrischer cross-sektionaler Studien

Melzer, Carolin 03 September 2013 (has links)
Hintergrund: Der Morbus Parkinson gehört zu den wichtigsten Bewegungsstörungen. Doch neben den motorischen Einschränkungen finden sich auch weitere den Patienten beeinträchtigende nicht-motorische Symptome. Neuropsychiatrische Krankheitsbilder rücken immer mehr mit in den Vordergrund. In dieser Arbeit soll mit Hilfe des Mini International Neuropsychiatric Interview (M.I.N.I.) evaluiert werden, welche neuropsychiatrischen Begleiterscheinungen in welcher Häufigkeit und in welcher Abhängigkeit zu verschiedenen Variablen auftreten. Zusätzlich soll die Häufigkeit und Schwere von Angst und Depression im OFF im Vergleich zum ON aus einer 2. Studie ermittelt werden. Patienten und Methoden: Von März bis Oktober 2008 wurden in 6 deutschen Zentren 225 Patienten mit idiopathischen Parkinsonsyndrom rekrutiert. Zunächst wurden die soziodemographischen Daten, das Datum der Erstdiagnose, relevante Begleiterkrankungen und aktuelle Medikation erfragt. Danach wurden Hoehn&Yahr Scale (H&Y), Unified Parkinson Rating Scale (UPDRS), Mini Mental State Examination (MMSE), affektive und motorische Fluktuationen sowie die klinische Diagnose Depression durch einen Studienarzt evaluiert. Den WHO-5-Fragebogen (World Health Oragnisation), den Despar-Fragebogen sowie das Beck Depression Inventory (BDI) führten die Patienten in Selbstevaluation durch. Das Mini International Neuropsychiatric Interview (M.I.N.I.) wurde anschließend durch einen in der Behandlung psychiatrischer Patienten erfahrenen Arzt durchgeführt. Zur Evaluation der Fluktuationen nicht-motorischer Symptome mit motorischen ON- und OFF-Phasen wurden die Daten einer zweiten multizentrischen Studie (NoMoFlu-Studie), bei der von Juli 2010 bis Februar 2011 100 Patienten mit Levodopa-Spätsyndrom rekrutiert wurden, hinzugezogen. Mein Schwerpunkt richtete sich auf die motorische Untersuchung mittels UPDRS III im ON und OFF, dem Teil 3 der modifizierten NMSScale, die sich mit Stimmung/Kognition befasst, und die Fragen 2 und 3 der visuellen Analogskala, die sich auf ängstliche und depressive Symptome beziehen. Mittels SPSS 17.0 wurden nach der deskriptiven Statistik kategoriale Variablen mit dem Chi-Quadrat-Test beziehungsweise mit dem Exakt-Test nach Fisher auf Abhängigkeiten überprüft. Zum Vergleich von Mittelwerten wurde der Mann-Whitney-U-Test herangezogen. ON und OFF Werte wurden durch einen gepaarten zweiseitigen t-Test miteinander verglichen. Für alle p-Werte wurde ein Signifikanzniveau von 0,05 festgelegt. Ergebnisse: Von den 225 Patienten waren 123 männlich und 102 weiblich. Das Alter lag im Durchschnitt bei 68,32+/-8,81 Jahren, der BMI bei 26,16+/-5,08 und die Krankheitsdauer betrug durchschnittlich 7,5 Jahre. Parkinson-bezogen ergaben sich folgende Werte: H&Y Median 2,5; UPDRS 46,23+/-20,57; MMSE 92,2% mit normaler kognitiver Leistungsfähigkeit; Despar 32,01+/-8,23; affektive Fluktuationen lagen bei 14,4% und motorische Fluktuationen bei 40,5% der Patienten vor. Anhand des WHO-5-Fragebogens konnte bei 35,4% eine Depression festgestellt werden, anhand des BDI bei 50,9% und klinisch bei 20,6%. Die Prävalenz der M.I.N.I. Störungsbilder ist folgender Maßen verteilt: bei 20,2% liegt eine Depression vor, bei 10,9% Agoraphobie ohne Panikstörung, bei 8,8% eine Dysthymie; 8,6% zeigen ein erhöhtes Suizidrisiko und 6,3% Depressionen mit melancholischen Merkmalen; 5,0% leiden an Sozialphobie, 2,3% an generalisierter Angststörung, 1,9% an Psychosen und 1,4% an Hypomanie; eine Panikstörung ohne Agoraphobie ist bei 0,9% und eine Zwangsstörung bei 0,5% der Patienten zu evaluieren. Manie, Posttraumatische Belastungsstörung, Alkohol- sowie Substanzmissbrauch und –abhängigkeit, Essstörungen und antisoziale Persönlichkeitsstörung fanden sich bei keinem der Patienten. In den Untersuchungen der NoMoFlu-Studie zeigte sich außerdem, dass die Schwere der motorischen Beeinträchtigung wie auch die Häufigkeit und Schwere der nicht-motorischen Symptome mit den OFF-Phasen statistisch signifikant zunimmt. Im motorischen Teil III des UPDRS wurden Werte im ON von durchschnittlich 19,1 +/- 11,7 und im OFF von 33,9 +/- 11,3 erreicht (p<0,001), im ON lag der Median des H&Y bei 2,5, im OFF bei 3 (p<0,001). Die Daten aus der VAS ergaben für Depression und Angst einen Anstieg der Häufigkeit im OFF (Depression 23,3% versus 47,3%, Angst 8,2% versus 27%) und der Schwere (Depression 10,1+/- 20,8 versus 29,9 +/- 31,7, p<0,001; Angst 4,1 +/- 14,7 versus 16,0 +/- 27,2, p<0,001). Schlussfolgerungen: Die erste Studie hat gezeigt, dass bestimmte neuropsychiatrische Krankheitsbilder bei Morbus Parkinson-Patienten in höherem Maße als in der Normalbevölkerung vorkommen. Die Prävalenz von depressiven Störungen zeigt in der Literatur allerdings eine große Spanne (13%-50% für Depression und 10%-15% für Dysthymie). Mögliche Gründe für die Unterschiede könnten in der Zusammensetzung der jeweiligen Patientenpopulation bestehen. Wie in unserer Studie sind an depressiven Störungen mehr Frauen beteiligt, die Werte für MMSE unterscheiden sich, UPDRS und H&Y liegen bei Patienten mit depressiver Symptomatik deutlich höher, motorische und affektive Fluktuationen sind häufiger zu beobachten, das Suizidrisiko ist erhöht und Angststörungen wie Sozialphobie oder Agoraphobie zeigen Assoziationen mit depressiven Störungen. Des Weiteren konnte anhand der NoMoFlu-Studie gezeigt werden, dass in den OFF-Phasen eine signifikant höhere Prävalenz depressiver Symptome herrscht als in den ON-Phasen und auch die Schwere zunimmt, was allerdings nicht mit der Schwere der motorischen Symptome korreliert werden konnte. Bipolare Störungen sind eher selten. Hypomanie und Manie konnten nicht im höheren Maße als in der Normalbevölkerung evaluiert werden. Dagegen konnten Angststörungen häufig beobachtet werden. Vor allem Sozialphobie und Agoraphobie zeigten erhöhte Prävalenz. Entgegen anderen Studien konnten Panik- und generalisierte Angststörung in unserer Studie nicht vermehrt registriert werden. Doch auch hier existiert eine große Spanne: für Panikstörungen von 5,0% bis 30%, 11,5% bis 50% für Sozialphobie, 18% für Agoraphobie und 11% bis 71% für generalisierte Angststörung. Eine mögliche Ursache könnte sein, dass Angst mit kognitiven und somatischen Veränderungen einhergeht, die ähnlich dem Morbus Parkinson sein können, und somit nicht erkannt wird. Unsere Studie zeigte, dass Angststörungen mit depressiven Störungen, motorischen Fluktuationen und einem erhöhten Suizidrisiko einhergehen. Die NoMoFlu-Studie bestätigte zusätzlich, dass Angststörungen mit erhöhter Bewegungseinschränkung in den OFF-Phasen an Prävalenz und Schwere zunehmen. Psychosen, Zwangsstörungen und Verhaltensstörungen konnten entgegen der internationalen Literatur, die einen Zusammenhang vor allem mit der dopaminergen Therapie beschreibt, nicht in höherem Maße als in der Normalbevölkerung evaluiert werden. Limitationen dieser Studien sind die begrenzte Patientenanzahl, die von unterschiedlichen Untersuchern durchgeführte Evaluation, die Abhängigkeit von der Mitarbeit des Patienten sowie das Fehlen vergleichender diagnostischer Test, die neuropsychiatrische Störungen aufdecken. Positiv ist das breit gefächerte Patientengut. Die Studie zeigt, dass neuropsychiatrische Störungen bei Morbus Parkinson weit verbreitet sind und eine adäquate Beurteilung in den klinischen Alltag mit aufgenommen werden sollte.
67

Developing a Methodology for Improving a Mini-Cell System Layout

Patnala, Avinash Kumar 03 October 2011 (has links)
No description available.
68

Survey of Temporary Anchorage Device Utilization in Graduate Orthodontic Programs and Orthodontic Practices in the United States

Shirck, Jeffrey Michael 27 August 2009 (has links)
No description available.
69

Effect of gravity on convective condensation at low mass velocity / Effet de la gravité sur la condensation convective à faible vitesse massique

Le Nguyen, Lan Phuong 06 July 2017 (has links)
Les écoulements diphasiques sont couramment utilisés dans de nombreux domaines dont, en particulier, le domaine spatial. La performance de ces systèmes est entièrement régie par les couplages se produisant entre les écoulements et les transferts de chaleur. Cette particularité a conduit, depuis les dernières décennies, au développement de nombreuses études sur les écoulements diphasiques en microgravité. Afin d'accroître la connaissance sur le comportement thermo-hydraulique de ces systèmes thermiques, la présente étude se focalise sur l'étude de la condensation dans un mini-tube en présence ou non de la force gravitationnelle. Pour étudier l'effet de la gravité sur cette configuration, un premier modèle instationnaire d'écoulement diphasique a été développé. Parallèlement, une analyse des effets de la gravité sur l'hydrodynamique et les transferts thermique a été menée dans deux sections d'essai possédant un diamètre interne commun de 3,4 mm et des vitesses massiques faibles à modérées. La première étude a été réalisée au cours de la 62e campagne de vols paraboliques de l'ESA. Elle a été dédiée à la détermination des coefficients de transfert de chaleur quasi-locaux se produisant à l'intérieur d'un tube de cuivre. Afin de visualiser également les régimes d'écoulement présents, un tube en verre a été inséré au sein de cet échangeur. L'effet de la gravité sur les écoulements et les transferts a ainsi été déterminé. La seconde expérience, menée au sol, a porté sur l'étude d'un écoulement de vapeur descendant au sein d'un tube en saphir placé verticalement. Un protocole de mesure permettant d'obtenir simultanément l'épaisseur du film de liquide ruisselant et le coefficient d'échange local associé a été développé. / Liquid-vapor two-phase flows have common applications in many fields including space thermal management systems. The performances of such systems are entirely associated to the coupling between thermal and hydrodynamic phenomena. Therefore, two-phase flows in microgravity condition have emerged as an active research area in the last decades. In order to complete the state of the art and to contribute to the increase in the knowledge of hydrothermal behavior of two-phase thermal management systems, the present study was conducted on convective condensation inside a mini tube, both in normal and micro gravity conditions. To analyze the effect of gravity on such flows, a preliminary transient modeling of the two-phase flow has been established. Simultaneously, an experimental investigation was carried out on the hydrodynamic and thermal behaviors of condensation flows in two test sections of 3.4 mm inner diameter at low and intermediate mass velocities. The first experiment was conducted during the 62nd ESA parabolic flights campaign. The test section was made with copper and allowed measurements of the quasi-local heat transfer coefficient. A glass tube was also inserted in the middle of the test section for the visualization of the two-phase flow regime. From this study, the changes in heat transfer coefficient and flow regime according to gravity variations were determined. The second experiment was carried out on ground in a sapphire tube installed vertically considering downward flow. The set-up was designed in order to measure simultaneously the local heat transfer coefficient and the thickness of the liquid film falling down along the tube wall.
70

Strenght and Flexibility Gains in Supplementary Weight Training Programs Using Two Different Weight Training Apparatus

Whiteley, Harold L. 08 1900 (has links)
The purpose of this study was to investigate strength and flexibility development as each is affected by three training programs using two apparatuss the Exer-Genie and the Super-Mini-Gym.

Page generated in 0.0701 seconds