• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 165
  • 149
  • 64
  • 29
  • 23
  • 10
  • 8
  • 6
  • 6
  • 6
  • 5
  • 5
  • 3
  • 3
  • 2
  • Tagged with
  • 526
  • 43
  • 40
  • 37
  • 35
  • 33
  • 26
  • 25
  • 24
  • 22
  • 21
  • 21
  • 19
  • 19
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Avaliação da força de inserção, remoção e resistência à fratura de mini-implantes utilizados nos tratamentos ortodônticos em diferentes regiões da maxila e mandíbula / Evaluation of insertion and removal forces and fracture strength of mini-implants used in orthodontic treatments in different regions of maxilla and jaw

Pesqueira, Eliana Ionara de Oliveira 24 June 2014 (has links)
O objetivo deste estudo foi identificar o melhor torque de inserção e remoção de mini-implantes inseridos em ossos artificiais com densidades similares às regiões anterior, mediana e posterior dos maxilares. Cento e vinte mini-implantes com desenho de dupla rosca (compactas e autoperfurantes) foram inseridos. Análises com microscopia eletrônica de varredura foram feitas antes e depois dos ensaios. Os valores de torque obtidos durante a inserção e remoção dos mini-implantes foram mensurados por um torquímetro digital. Os resultados analisados levaram a concluir que os torques de inserção e remoção eram maiores conforme aumentava a densidade óssea e a espessura da cortical. O desenho das roscas dos mini-implantes influenciou no torque de inserção. As roscas com menores passos aumentaram o valor do torque de inserção. A perfuração óssea anterior à instalação diminui o torque de inserção independente da densidade óssea. Ocorreu um aumento de torque principalmente com o aumento da densidade óssea e não necessariamente com o aumento da espessura da cortical sugerindo que a densidade óssea do osso trabecular deve ser considerada no planejamento de instalação dos mini-implantes. / The objective of this study was to identify the best insertion torque and removal of mini-implants inserted in artificial bone with densities similar to anterior, middle and posterior regions of the jaws. One hundred and twenty mini-implants with a twin crew design (compact and self-drilling) were inserted into artificial bones with densities and thickness similar to cortical and trabecular bones of the maxilla and mandible. Analysis with electron microscopy was performed before and after the tests. The torque values obtained during the insertion and removal were measured using a digital torque wrench. The analyzed results led to the conclusion that the insertion and removal torques were larger with increase in bone density and cortical thickness. The design of the threads of the mini-implants influenced the insertion torques. Threads with smaller steps increased the value of insertion torques. The anterior bone drilling installation reduces the insertion torque independent of bone density. Torque increased mainly by increasing the bone density and not necessarily with increased cortical thickness suggesting that the bone density of the trabecular bone must be taken into account con in designing and installation of mini-implants.
42

Overdentures mandibulares retidas por mini-implantes ou implantes convecionais: avaliação da função mastigatória e colonização microbiana / Mandibular overdentures retained by mini or conventional implants: assessment of masticatory function and microbial colonization

Cunha, Tatiana Ramirez 09 June 2015 (has links)
Implantes de diâmetro reduzido, ou mini-implantes, têm sido recentemente considerados para a retenção e suporte de overdentures mandibulares em pacientes totalmente desdentados. No entanto, pouco se sabe sobre o desempenho da função mastigatória com esse tipo de tratamento e da microbiota associada aos mini-implantes. Portanto, estudos clínicos que validem o tratamento com mini-implantes e overdentures são necessários. Assim, os objetivos deste estudo foram: 1) avaliar a habilidade e performance mastigatórias de indivíduos portadores de overdentures mandibulares retidas por quatro ou dois mini-implantes (grupos I e II, respectivamente) ou dois implantes convencionais (grupo III); 2) comparar a performance mastigatória destes indivíduos com a encontrada em portadores de próteses totais convencionais (grupo IV comparador externo); e 3) comparar qualitativa e quantitativamente a microbiota peri-implantar de mini-implantes e de implantes convencionais. Participaram deste estudo 60 indivíduos portadores de overdentures mandibulares (20 de cada grupo) e 20 portadores de próteses totais convencionais. Três meses após a instalação das overdentures mandibulares (grupos I, II e III), a habilidade mastigatória (HM) foi avaliada por meio de um questionário desenvolvido para esta finalidade. A performance mastigatória (PM) dos participantes foi avaliada seis meses após a instalação das overdentures por meio de um método que determina a alteração de cor de uma goma de mascar utilizada como alimento teste. A microbiota do sulco peri-implantar dos mini-implantes do grupo II e dos implantes convencionais (grupo III) foi identificada e quantificada pelo método DNA Checkerboard (38 espécies de microrganismos avaliadas) em dois momentos: T0 (primeira coleta), realizada 3 meses após a exposição dos implantes à cavidade oral, e T1 (segunda coleta), seis meses após a primeira coleta. Os grupos foram comparados por meio de testes adequados à distribuição dos dados (&alpha;=5%). Embora a HM tenha sido semelhante entre os grupos I, II e III, a dificuldade em mastigar alimentos moles associada à overdenture foi maior para o grupo III (Kruskal-Wallis, p=0,041). A PM também foi similar nos grupos I, II e III, mas significantemente maior do que a do grupo IV (Tukey, p<0,05). As 38 espécies alvo do estudo foram detectadas nos dois tipos de implantes em T0 e T1, com exceção da espécie E. faecalis nos implantes convencionais em T1. Houve uma diminuição significante na quantidade total de bactérias e fungos no grupo II e aumento no grupo III (Wilcoxon Pareado, p<0,05) no período analisado. A quantidade total de microrganismos no grupo III foi significantemente maior do que no grupo II em T1 (Mann-Whitney; p<0,05), sendo que mais de 70% das espécies avaliadas estavam presentes em maior quantidade no grupo III (Mann-Whitney; p<0,05). Levando-se em conta as limitações deste estudo, pode-se concluir que overdentures mandibulares retidas por quatro ou dois mini-implantes são tão efetivas quanto aquelas retidas por dois implantes convencionais quanto a habilidade e performance mastigatórias, e que este tipo de reabilitação promove uma performance mastigatória superior à encontrada em portadores de próteses totais convencionais. Além disso, a microbiota do sulco peri-implantar de mini-implantes é quantitativamente inferior e qualitativamente semelhante à microbiota associada a implantes convencionais quando utilizados para reter/suportar overdentures mandibulares. / Narrow diameter implants, or mini dental implants, have recently been considered to retain and to support mandibular and maxillary overdentures in completely edentulous subjects. However, there is scant information about the performance of masticatory function with this type of treatment and the microbiota associated with mini-implants. Therefore, clinical trials to valid the treatment with mini implants and overdentures are necessary. Thus, this study aimed to: 1) assess the ability and masticatory performance in mandibular overdenture wearers after the insertion of four or two mini implants (group I and II, respectively) or two standard-size implants (group III); 2) compare their masticatory performance with that obtained by complete denture wearers (group IV external comparison); 3) compare qualitatively and quantitatively the peri-implant microbiota of mini and standard-size implants. Sixty mandibular overdenture wearers (20 per group) and 20 complete denture wearers participated in the study. Three months after the insertion of the mandibular overdentures (group I, II and III) the masticatory ability (MA) was assessed by a questionnaire developed for this purpose. The masticatory performance (MP) was assessed six months after the insertion of the overdentures by a test using a color-changeable chewing gum. The peri-implant microbiota of mini (group II) and standard-size implants (group III) was identified and quantified by DNA Checkerboard method (38 microorganisms species assessed) in two times: T0 (first collect) three months after the implants exposure to the oral cavity, and T1 (second collect) six months after T0. The groups were compared by tests according to data distribution (&alpha;=5%). Although the MA was similar between the assessed groups (I, II and III), the difficult to chew soft foods caused by the overdenture was higher for group III (Kruskal-Wallis, p=0,041). The MP was similar between groups I, II and III. However, it was higher than the MP in group IV (Tukey, p<0,05). All the 38 species were detected in the two implants in T0 and T1, except the E. faecalis in group III in T1. There was a significant decrease in the total amount of bacteria and fungi in group II and increase in group III (Wilcoxon Pareado; p<0,05) during the period analysed. The total amount of microorganisms in group III was higher than in group II in T1 (Mann-Whitney; p<0,05), with over than 70% of the species identified in larger amount in group III (Mann-Whitney; p<0,05). Taking into account the limitations of this study, it was concluded that the mandibular overdentures retained by four or two mini implants are as effective as those retained by two standard-size implants considering the masticatory ability and performance. Moreover, these treatments promote higher masticatory performance than that found in conventional dentures wearers. In addition, the peri-implant microbiota of mini implants is quantitatively lower and qualitatively similar to the microbiota associated with standard-size implants used to retain overdentures.
43

Construção de mutantes de Pseudomonas abrigando diferentes PHA sintases em seu genoma, para produção de 3HB-co-3HAMCL. / Construction of recombinant Pseudomonas strains harboring different PHA synthases in its genome to produce 3HB-co-3HAMCL.

Oliveira Filho, Edmar Ramos de 02 February 2017 (has links)
Polihidroxialcanoatos (PHA) são biopolímeros naturalmente produzidos e acumulados por diversos organismos, como bactérias, archaeas e alguns eucariontes, como fungos e leveduras. São materiais termoplásticos, biodegradáveis, biocompatíveis e podem ser produzidos a partir de fontes renováveis, exibindo grande potencial para substituir plásticos produzidos a partir de recursos não renováveis. Copolímeros híbridos de PHA, que podem ser formados por monômeros de cadeia curta e média, como P(3HASCL-co-3HAMCL), apresentam características físico-químicas diferenciadas, semelhantes às dos plásticos derivados de petróleo, sendo por isso interessantes para a indústria de materiais. A PHA sintase é considerada a enzima chave na síntese de PHA, responsável por catalisar a polimerização de diferentes monômeros de (R)-hidroxiacil-CoA, influenciando a composição monomérica do polímero formado. Sistemas de recombinação baseados em transposons bacterianos são explorados como ferramentas moleculares para inserção de sequências gênicas no cromossomo de bactérias Gram-negativas. Por exemplo, elementos mini-Tn7 podem ser prontamente transferidos para a construção de cepas recombinantes. No presente trabalho, é apresentada a construção de diferentes linhagens recombinantes a partir de Pseudomonas sp. LFM 046 e LFM 461, portando em seus cromossomos genes de PHA sintase de Ralstonia eutropha, Aeromonas hydrophila ou Aeromonas sp. TSM 81. Clones candidatos foram triados quanto a inserção das sequências de interesse em seu cromossomo, sendo os positivos avaliados em relação à capacidade de produção de PHA em ensaios em agitador rotativo, com glicose como única fonte de carbono. Um dos recombinantes obtidos se mostrou produtor do copolímero P(3HB-co-3HO-co-3HD), acumulando aproximadamente 2 % de sua massa seca celular na forma de PHA. / Polyhydroxyalkanoates (PHA) are biopolymers naturally produced and accumulated by many organisms such as bacteria, archaeas and some eukaryotes, such as fungi and yeasts. As thermoplastics, biodegradable, biocompatible and possibly made from renewable resources, they exhibit great potential to replace oil-derived plastics. Hybrid PHA copolymers can be formed by short and medium-chain monomers, P(3HASCL-co-3HAMCL), and present industry desired physicochemical properties, becoming similar to conventional oil-based plastics. PHA synthase is the key enzyme in PHA biosynthesis, responsible for catalyzing the polymerization of (R)-hydroxyacyl-CoA molecules, influencing polymer monomeric composition. Tn7-based recombination strategies represent powerful molecular tolls designed for gene delivery in Gram-negative bacteria, as mini-Tn7 elements can be readily transferred to recombinants production. In this work, its presented the constructions of recombinant Pseudomonas strains harboring PHA synthase genes from Ralstonia eutropha and Aeromonas strains in specific sites of its chromosome, and the production of P(3HB-co-3HO-co-3HD). Obtained clones were screened to confirm chromosomic insertion of the phaC sequences. Positive clones PHA production and composition were evaluated in shaken-flasks assays using glucose as the only carbon source. One of the constructed recombinants accumulated P(3HB-co-3HO-co-3HD), corresponding about to 2 % of its Cell Dry Weight as PHA.
44

Avaliação da precisão de um guia radiográfico-cirúrgico para inserção de mini-implantes / Accuracy evaluation of a radiographic-surgical guide for mini-implant placement

Sérgio Estelita Cavalcante Barros 23 June 2008 (has links)
PROPOSIÇÃO Avaliou-se radiograficamente o grau de precisão de um guia radiográfico-cirúrgico na predição do posicionamento final de mini-implantes inseridos no septo inter-radicular e, sequencialmente, determinou-se um índice de risco para normatizar a indicação do procedimento de inserção dos mini-implantes. MATERIAL E MÉTODOS Um total de 53 mini-implantes foram inseridos no septo inter-radicular vestibular da região posterior da maxila e/ou mandíbula de 27 pacientes com idade média de 19,17 ± 9,06 anos (idade mínima de 12,72 anos e máxima de 56,37 anos). O Guia Radiográfico-Cirúrgico Graduado (GRCG) foi utilizado para inserir os mini-implantes no centro do septo de forma equidistante em relação às raízes dos dentes adjacentes. As distâncias entre o mini-implante e as raízes dos dentes adjacentes foram mensuradas nas 53 radiografias pós-cirúrgicas com intuito de avaliar a precisão do GRCG a partir do grau de centralização do mini-implante no septo. O grau de imprecisão do GRCG foi associado à largura do septo e ao diâmetro do mini-implante para compor a fórmula do índice de risco utilizada na avaliação do risco cirúrgico de inserção dos mini-implantes. RESULTADOS O grau de imprecisão do GRCG mostrou que, em média, os mini-implantes foram inseridos com um desvio de 0,13mm (±0,13) em relação ao centro do septo. O valor médio do índice de risco (IR) foi menor do que 1, significando um reduzido risco cirúrgico. CONCLUSÕES A ligação estabelecida entre os procedimentos radiográfico e cirúrgico proveu ao GRCG um reduzido grau de imprecisão de 0,13mm, e uma acurada predição do posicionamento final do mini-implante no septo inter-radicular, contribuindo para um reduzido risco cirúrgico (IR<1). / OBJECTIVE This study evaluated the radiographic-surgical guide accuracy to predict post-surgical mini-implant positioning in the interradicular septum. Additionally, a risk index to standardize surgical procedure indication for mini-implant insertion was determined. MATERIAL AND METHODS A total of fifty-three titanium mini-implants were placed in the buccal interradicular septum of the posterior maxillary and/or mandibular region of 27 patients with a mean age of 19.17 ± 9.06 years (ranging from 12.72 to 56.37 years). The Graduated Radiographic-Surgical Guide (GRSG) was used to insert mini-implants in the interradicular septum in a centralized and equidistant position regarding adjacent tooth roots. The fifty-three post-surgical radiographs were used to measure the distances between mini-implants and adjacent tooth roots to evaluate GRSG accuracy in obtaining mini-implant centralized position in the septum. The GRSG inaccuracy degree was related to the septum width and the mini-implant diameter to obtain risk index formula, which was used to predict surgical risks during mini-implants insertion. RESULTS The GRSG inaccuracy degree showed that, on average, the mini-implants were 0.13mm (±0.13) displaced regarding the centralized position initially intended. The risk index (RI) presented a mean value smaller than 1, indicating a reduced surgical risk. CONCLUSION The link established between radiographic and surgical procedures propitiated a small GRSG inaccuracy degree of 0.13mm, allowing an accurate prediction of the final mini-implant positioning in the interradicular septum, which contributed to a low surgical risk (RI<1).
45

Overdentures mandibulares retidas por mini-implantes ou implantes convecionais: avaliação da função mastigatória e colonização microbiana / Mandibular overdentures retained by mini or conventional implants: assessment of masticatory function and microbial colonization

Tatiana Ramirez Cunha 09 June 2015 (has links)
Implantes de diâmetro reduzido, ou mini-implantes, têm sido recentemente considerados para a retenção e suporte de overdentures mandibulares em pacientes totalmente desdentados. No entanto, pouco se sabe sobre o desempenho da função mastigatória com esse tipo de tratamento e da microbiota associada aos mini-implantes. Portanto, estudos clínicos que validem o tratamento com mini-implantes e overdentures são necessários. Assim, os objetivos deste estudo foram: 1) avaliar a habilidade e performance mastigatórias de indivíduos portadores de overdentures mandibulares retidas por quatro ou dois mini-implantes (grupos I e II, respectivamente) ou dois implantes convencionais (grupo III); 2) comparar a performance mastigatória destes indivíduos com a encontrada em portadores de próteses totais convencionais (grupo IV comparador externo); e 3) comparar qualitativa e quantitativamente a microbiota peri-implantar de mini-implantes e de implantes convencionais. Participaram deste estudo 60 indivíduos portadores de overdentures mandibulares (20 de cada grupo) e 20 portadores de próteses totais convencionais. Três meses após a instalação das overdentures mandibulares (grupos I, II e III), a habilidade mastigatória (HM) foi avaliada por meio de um questionário desenvolvido para esta finalidade. A performance mastigatória (PM) dos participantes foi avaliada seis meses após a instalação das overdentures por meio de um método que determina a alteração de cor de uma goma de mascar utilizada como alimento teste. A microbiota do sulco peri-implantar dos mini-implantes do grupo II e dos implantes convencionais (grupo III) foi identificada e quantificada pelo método DNA Checkerboard (38 espécies de microrganismos avaliadas) em dois momentos: T0 (primeira coleta), realizada 3 meses após a exposição dos implantes à cavidade oral, e T1 (segunda coleta), seis meses após a primeira coleta. Os grupos foram comparados por meio de testes adequados à distribuição dos dados (&alpha;=5%). Embora a HM tenha sido semelhante entre os grupos I, II e III, a dificuldade em mastigar alimentos moles associada à overdenture foi maior para o grupo III (Kruskal-Wallis, p=0,041). A PM também foi similar nos grupos I, II e III, mas significantemente maior do que a do grupo IV (Tukey, p<0,05). As 38 espécies alvo do estudo foram detectadas nos dois tipos de implantes em T0 e T1, com exceção da espécie E. faecalis nos implantes convencionais em T1. Houve uma diminuição significante na quantidade total de bactérias e fungos no grupo II e aumento no grupo III (Wilcoxon Pareado, p<0,05) no período analisado. A quantidade total de microrganismos no grupo III foi significantemente maior do que no grupo II em T1 (Mann-Whitney; p<0,05), sendo que mais de 70% das espécies avaliadas estavam presentes em maior quantidade no grupo III (Mann-Whitney; p<0,05). Levando-se em conta as limitações deste estudo, pode-se concluir que overdentures mandibulares retidas por quatro ou dois mini-implantes são tão efetivas quanto aquelas retidas por dois implantes convencionais quanto a habilidade e performance mastigatórias, e que este tipo de reabilitação promove uma performance mastigatória superior à encontrada em portadores de próteses totais convencionais. Além disso, a microbiota do sulco peri-implantar de mini-implantes é quantitativamente inferior e qualitativamente semelhante à microbiota associada a implantes convencionais quando utilizados para reter/suportar overdentures mandibulares. / Narrow diameter implants, or mini dental implants, have recently been considered to retain and to support mandibular and maxillary overdentures in completely edentulous subjects. However, there is scant information about the performance of masticatory function with this type of treatment and the microbiota associated with mini-implants. Therefore, clinical trials to valid the treatment with mini implants and overdentures are necessary. Thus, this study aimed to: 1) assess the ability and masticatory performance in mandibular overdenture wearers after the insertion of four or two mini implants (group I and II, respectively) or two standard-size implants (group III); 2) compare their masticatory performance with that obtained by complete denture wearers (group IV external comparison); 3) compare qualitatively and quantitatively the peri-implant microbiota of mini and standard-size implants. Sixty mandibular overdenture wearers (20 per group) and 20 complete denture wearers participated in the study. Three months after the insertion of the mandibular overdentures (group I, II and III) the masticatory ability (MA) was assessed by a questionnaire developed for this purpose. The masticatory performance (MP) was assessed six months after the insertion of the overdentures by a test using a color-changeable chewing gum. The peri-implant microbiota of mini (group II) and standard-size implants (group III) was identified and quantified by DNA Checkerboard method (38 microorganisms species assessed) in two times: T0 (first collect) three months after the implants exposure to the oral cavity, and T1 (second collect) six months after T0. The groups were compared by tests according to data distribution (&alpha;=5%). Although the MA was similar between the assessed groups (I, II and III), the difficult to chew soft foods caused by the overdenture was higher for group III (Kruskal-Wallis, p=0,041). The MP was similar between groups I, II and III. However, it was higher than the MP in group IV (Tukey, p<0,05). All the 38 species were detected in the two implants in T0 and T1, except the E. faecalis in group III in T1. There was a significant decrease in the total amount of bacteria and fungi in group II and increase in group III (Wilcoxon Pareado; p<0,05) during the period analysed. The total amount of microorganisms in group III was higher than in group II in T1 (Mann-Whitney; p<0,05), with over than 70% of the species identified in larger amount in group III (Mann-Whitney; p<0,05). Taking into account the limitations of this study, it was concluded that the mandibular overdentures retained by four or two mini implants are as effective as those retained by two standard-size implants considering the masticatory ability and performance. Moreover, these treatments promote higher masticatory performance than that found in conventional dentures wearers. In addition, the peri-implant microbiota of mini implants is quantitatively lower and qualitatively similar to the microbiota associated with standard-size implants used to retain overdentures.
46

Risco de desnutrição em idosos na comunidade / Risk of malnutrition in the aged in the community

Larissa Joana Exposto de Carvalho Matos 12 August 2005 (has links)
O trabalho estudou o estado nutricional de uma amostra aleatória (n = 98) de idosos vivendo na zona urbana do Distrito Bonfim Paulista e procurou identificar alguns fatores relacionados ao risco de desnutrição. Os idosos selecionados foram avaliados quanto ao estado nutricional através da “Mini Avaliação Nutricional” (MAN) e através do recordatório alimentar de 24 horas. Também foi elaborado um questionário domiciliar especifico contendo questões relacionadas à escolaridade, renda do idoso e da família, perfil multidimensional, impressão subjetiva de saúde e de qualidade de vida, atividade de trabalho, moradia, doenças crônicas, atividade de vida diária e participação social. Procuramos, desta forma, identificar a prevalência de desnutrição e risco de desnutrição na comunidade e identificar fatores associados com a menor pontuação na MAN, ou seja, fatores que possam contribuir para um pior prognóstico nutricional. Participaram do trabalho 98 voluntários sendo 30 (30,6%) idosos do sexo masculino e 68 (69,4%) do sexo feminino. Detectamos a prevalência de 11,2% de idosos desnutridos, 37,7% de idosos sob risco de desnutrição e 51,1% de bem nutridos de acordo com MAN. Após avaliação da normalidade, usamos testes não paramétricos (Kruskall-Wallis) quando estes três grupos foram comparados em relação às diferentes variáveis estudadas como idade, IMC, consumo energético, gasto energético e variáveis neuropsiquiátricas. Observamos que a MAN é um método viável e de fácil aplicabilidade em idosos vivendo em comunidades brasileiras e que nossos resultados foram semelhantes à maioria dos estudos que usaram a MAN como instrumento de investigação da prevalência de “risco de desnutrição” na comunidade. Paralelamente, acreditamos que a variável IMC não é um bom parâmetro para caracterização de desnutrição e que o estado de saúde mental do idoso contribui fortemente para o seu estado nutricional. Em relação ao consumo energético podemos dizer que, continua sendo uma das principais causas de desnutrição na terceira idade e pode estar presente mesmo entre os idosos caracterizados como nutridos. Para avaliação de associações de determinados fatores, discriminados no questionário geral, com o estado nutricional, montamos tabelas 2X2 e usamos o teste exato de Fisher. Procuramos observar associações entre algumas variáveis com dois grupos: o primeiro que tinha escore inferior a 23,5 e outro que possuía escore superior a 24 na MAN acreditando que estes valores definem, respectivamente, um pior e melhor estado nutricional. Desta forma foi possível observar que fatores como o analfabetismo, baixa renda familiar, falta de participação social e em atividades de trabalho possuem forte correlação com escores inferiores na Mini Avaliação Nutricional apesar de não fazerem parte do seu conteúdo. A auto avaliação do estado de saúde ou impressão subjetiva de saúde possui forte correlação com a maior ou menor pontuação na MAN. Finalmente, apesar de não ter havido correlação estatística, acreditamos que haja uma tendência à maior prevalência de desnutrição em faixas etárias mais elevadas. / The present investigation was carried out to study the nutritional status of a random sample (n = 98) of aged subjects living in the urban zone of the Bonfim Paulista district and to identify some factors related to the risk of malnutrition. The chosen aged subjects were evaluated for nutritional status by the \"Mini Nutritional Assessment\" (MNA) and by the 24-hour food recall method. Also a specific domiciliary questionnaire was elaborated with questions related to educational level, income of the aged and of the family, multidimensional profile, self- reported health status, work activity, housing, chronic illnesses, activities of daily living and social participation. We were interested in identifying the prevalence of malnutrition and risk of malnutrition in the community and factors associated with the lower scores on the MNA, i.e., factors that can contribute to a worse nutritional prognosis. Ninety-eight (98) volunteers participated in the study, 30 of them (30.6%) males and 68 (69.4%) females. On the basis of the MNA, we detected an 11.2% prevalence of malnourished subjects, a 37.7% prevalence of subjects at risk of malnutrition and a 51.1% prevalence of well-nourished subjects. After evaluation of normality, we used nonparametric (Kruskall-Wallis) methods to compare these three groups. The groups had were compared for age, body mass index (BMI), energy intake, energy expenditure and psychiatrics variables. We observed that the MNA is a viable method of easy applicability in aged subjects living in Brazilian communities and that our results were similar to most of those obtained in studies using the MNA as an instrument of inquiry of the prevalence of \"risk of malnutrition\" in the community. At the same time, we believe that the BMI is not a good parameter for malnutrition characterization and that the mental health of the aged contributes strongly to their nutritional status. Regarding energy intake, we can say that it continues to be one of the main causes of malnutrition in the third age and can be present even among elderly subjects considered to be well-nourished. For evaluation of associations of determined variables, discriminated in the general questionnaire, with the nutritional status, we analyzed 2X2 contingency tables and used Fisher’s exact test. We were interested in determining associations between some variables in two groups: one with a score of less than 23.5 points and the other with a score of more than 24 points on the MNA, since we believe that these values define a worse and a better nutritional status, respectively. On this basis, it was possible to observe that factors such as illiteracy, low family income, and lack of social and work activities are strongly correlated with a low score on the MNA, although they are not part of its content. The self-reported health status or subjective impression of health is strongly correlated with a higher or lower score on the MNA. Finally, although the correlation was not statistically significant, we believe that malnutrition tends to be more prevalent in older age ranges.
47

Identificação da fragilidade em idosos a partir do risco nutricional / Identification of frailty in elderly from nutritional risk investigation

Mariana Staut Zukeran 29 May 2017 (has links)
Introdução: Dentre os desfechos negativos que acometem os idosos, a síndrome da fragilidade é preocupante, pois tem como consequências piora da funcionalidade, comorbidades e antecipação da morte. Assim, sua prevenção e detecção precoces são essenciais para a saúde pública. A identificação desta síndrome tem sido mais comumente realizada por meio dos critérios de Fried et al. (2001), os quais necessitam de equipamentos específicos e equipe especializada. Por sua vez, o estado nutricional parece estar fortemente associado ao desenvolvimento da fragilidade. Portanto, este trabalho tem o objetivo de investigar a associação existente entre o risco nutricional e a identificação de fragilidade. Métodos: Foram estudados pacientes em ambulatório de geriatria, e foram aplicados os critérios de Fried et al. (2001), a Mini Avaliação Nutricional (MAN), nas suas formas reduzida e completa (MAN-R e MAN-C), e algumas medidas antropométricas. Os dados foram avaliados quanto à normalidade (teste Shapiro-Wilk); a sensibilidade e a especificidade da MAN em detectar a fragilidade foram medidas por meio da curva Receiver Operating Characteristics (ROC). Resultados: A amostra final foi composta por 422 (72,8%) mulheres e 158 (27,2%) homens. A prevalência de fragilidade foi de 41,1% (n=256) e pré fragilidade de 45,0% (n=261). A MAN-R identificou 78 (13,4%) idosos desnutridos e 258 (44,5%) sob risco de desnutrição. O melhor ponto de corte para fragilidade nas mulheres foi &#8804;=24,5 pontos (AUC=0,849; sensibilidade=79,7 e especificidade=78,3) para MAN-C e &#8804;=11,0 pontos (AUC=0,795; sensibilidade=69,0 e especificidade=80,4) para a MAN-R. Dentre os homens, os melhores pontos de corte foram &#8804;=23,0 (AUC=0,877; sensibilidade=79,2 e especificidade=88,2) para MAN-C e &#8804;=11 (AUC=0,821; sensibilidade=81,9 e especificidade=76,5) para MAN-R. Ambas as formas da MAN não apresentaram associação significativa para identificação da pré fragilidade. Conclusão: Foi verificada associação significativa entre a MAN e a presença da síndrome da fragilidade, porém não com o estado de pré-fragilidade. Ambas as versões, reduzida e completa, foram adequadas para identificação da fragilidade. A MAN-C demonstra correlação mais alta do que a MAN-R e indica pontos de corte diferentes de acordo com o gênero. / Background: The frailty syndrome is a concern among the elderly due to some negative outcomes such as loss of functionality, comorbidities and anticipation of death. Thus, its prevention and early detection are essential for public health. Fried et al. (2001) criterion has been used to identify this syndrome; however, it requires specific equipment and specialized team. The nutritional status is strongly associated with the development of frailty. Therefore, this study aims to investigate the association between nutritional risk and the identification of frailty. Methods: We studied patients in a geriatrics outpatient clinic, in which Fried criterion, the Mini-Nutritional Assessment (MNA), on both short form (MNA-SF) and long form (MNA-LF), and anthropometric measurements were applied. The data were analyzed according to normality (Shapiro-Wilk test), and MNA\'s ability to detect frailty was measured by Receiver Operating Characteristics (ROC) curves. Results: The final sample was composed by 422 (72.9%) women and 158 (27.2%) men. The prevalence of frailty was 41.1% (n=256) and pre-frailty was 45.0% (n=261). The MAN-SF identified 78 (13.4%) malnourished and 258 (44.5%) at risk of malnutrition. The best cut-off point to frailty in women was &#8804;=24.5 points (AUC=0.849; sensitivity=79.7 and specificity=78.3) for MAN-LF and &#8804;=11 points (AUC=0.795; sensitivity=69.0 and specificity=80.4) for MAN-SF. Among the men, the best cut-off point were &#8804;=23.0 (AUC=0.877; sensitivity=79.2 and specificity=88.2) for MAN-LF and &#8804;=11 points (AUC=0.821; sensitivity=81.9 and specificity=76.5) for MAN-SF. Both MNA forms did not present significant association to detect pre-frailty. Conclusion: MNA forms presented significant association to detect frailty, although neither is suitable to detect pre-frailty. MNA-LF shows a higher correlation than MNA-SF e indicates different cut-off points according to gender.
48

UM ESPECTROMETRO \"MINI-ORANGE\" PARA ELECTRONS / A mini-orange spectrometer for electrons

Silva, Nelson Canzian da 04 May 1990 (has links)
Foi projetado e construído um espectrômetro Mini-Orange (MO) para eléctrons, utilizando imãs planos permanentes e um detector de barreira de superfície. Foram determinadas as funções de transmissão de diferentes configurações do sistema, para energias entre 200-1100 keV. Foi desenvolvido um modelo matemático do sistema, a partir de solução analítica para o campo de um imã plano e da integração numérica da equação de movimento dos eléctrons no campo de MO. As funções de transmissão assim obtidas foram comparadas aos resultados experimentais e mostraram um bom acordo para energias baixas e intermediárias. / A Mini-Orange spectrometer for electrons was designed and built, using plane permanent magnets and a surface barrier detector. Transmission functions were obtained for various system configurations and for energies between 200-1100 keV. A mathematical model of the system was developed, using the analytical solution for the field of a plane magnet and the numerical integration of the equation of motion of the electrons in the MO magnetic field. The calculated transmission functions were compared to the experimental data, showing a good agreement for low and intermediate energies.
49

Estado nutricional de idosos em um hospital público de Rio Branco, Acre, 2006-2007 / Nutritional status of elderly in a public hospital in Rio Branco, Acre, 2006-2007

Camêlo, André Alves 03 May 2010 (has links)
Introdução: Apesar de haver sido relatada grande variação da prevalência de desnutrição na admissão hospitalar, observa-se consenso ao afirmar que a prevalência aumenta e sua intensidade se agrava quanto maior o tempo de internação. Ao mesmo tempo, as desordens nutricionais estão diretamente implicadas com aumento da morbi-mortalidade, sendo escassos os estudos sobre estado nutricional em pacientes hospitalizados na região norte do Brasil. Objetivos: Descrever o estado nutricional dos idosos internados em hospital geral em Rio Branco, Acre através da Mini Avaliação Nutricional (MAN) e verificar a associação entre o estado nutricional e as características sociodemográficas, de saúde e estilo de vida dos idosos. Métodos: O presente estudo é um recorte de um estudo transversal de base institucional, realizado em hospital de nível terciário da região Amazônica em que foram estudados 318 idosos na primeira admissão nesse hospital, no período de janeiro de 2006 a julho de 2007. Resultados: A prevalência de risco para desnutrição foi de 33 por cento e de desnutrição, 21 por cento. Ser casado evidenciou em proteção para o idoso ter boas condições nutricionais, como também, maior escolaridade e fontes de ingresso. Enquanto que hipertensão, diabetes, declínio da capacidade funcional e polifarmácia evidenciaram em piora no estado nutricional do idoso. Conclusões: Viver com familiares e/ou amigos (OR=3,74); ter hipertensão e diabetes associadas (OR=4,22); dependência parcial (OR=14,92) e dependência importante (OR=41,56); e consumir mais de três medicamentos diários (OR=17,07), tiveram associação estatisticamente significante com a desnutrição. Em relação ao risco nutricional, conferiram associação viver com familiares e/ou amigos (OR=3,14); ser portador de hipertensão e diabetes simultaneamente (OR=5,75) e consumir mais de três medicamentos por dia (OR=6,64). A avaliação nutricional deve ser incorporada na atenção de saúde como um todo, com medidas de saúde complementares, que evitem o declínio de sua condição nutricional no momento e após a internação / Introduction: Malnurition prevalence at hospital admission has wild variation; however, it is consensus that its prevalence and intensity increase the longer they stay interned. Nutritional disordes are also involved in morbidity and mortality rate with little research on the nutritional status in hospitalized patients in the north of Brazil. Objectives: This study has the objective to describe nutritional status among elderly patients in general hospital in Rio Branco, Acre using Mini Nutritional Assessment (MNA) and to verify the association between nutritional status andsociodemographic, health conditions and lifestyle among those elderly.Methods: This study is an outline of an institutional research project conducted in tertiary hospital in the Amazon region, which studied 318 elderly people in the first admission to that hospital, from january 2006 to july 2007. Results: The prevalence of risk for malnutrition was 33 per cent and malnutrition, 21 per cent. Married elders showed evidenced of having good nutritional status, better education and higher income as well. Healthy habits did not correlate with changes in nutritional assessment of the elderly. While hypertension, diabetes, declining functional status and polypharmacy showed deterioration in the nutritional status of the elderly. Conclusions: To live with family or friends (OR=3.74), have hypertension and diabetes associated (OR=4.22); partial dependence (OR=14.92) and important (OR=41.56); consuming more three drugs per day (OR=17.07); had association with malnutrition. In relation to nutritional risk the association gave live with family or friends (OR=3.14); be patient with hypertension and diabetes at same time (OR=5.75) and consume more than three medications per day (OR=6.64). Nutritional assessment is important for the holistic care of the elderly and must be incorporated in health care as a whole, with additional health measures that prevent their decline in nutritional status at the time and after hospitalization
50

Overdentures mandibulares retidas por mini-implantes: acompanhamento de 2 anos de um ensaio clínico randomizado / Mini-implant-retained mandibular overdentures: 2-year follow-up a randomized trial

Crizóstomo, Luciana Costa 25 July 2017 (has links)
O tratamento com mini-implantes tem sido utilizado para retenção de overdentures por possuir menor custo, menor desconforto pós-operatório e proporcionar adequada reabilitação da estética, função e fonação. Este ensaio clínico randomizado, com acompanhamento de 2 anos, foi realizado com o intuito de comparar a qualidade de vida associada à saúde bucal (QVSB), satisfação do paciente, bem como as taxas de sucesso de implantes e overdentures, retidas por implantes ou mini-implantes. Na fase inicial, a amostra foi composta de 120 indivíduos edêntulos que foram alocados aleatoriamente em três grupos de acordo com o tratamento recebido: (GI) quatro mini-implantes, (GII) dois mini-implantes, ou (GIII) dois implantes regulares. Durante o acompanhamento de 1 e 2 anos, a amostra foi reduzida para 106 e 96 participantes, respectivamente. A QVSB, mensurada pelo questionário OHIP-EDENT, e a satisfação (aferida por questões específicas respondidas em EVA 100mm) foram avaliadas antes da intervenção e após o período de acompanhamento. Outra variável utilizada para verificar a efetividade do tratamento foi a taxa de sucesso de implantes e overdentures, que foi obtida por meio de parâmetros clínicos e sobrevivência dos implantes. Os grupos foram comparados por meio de Equações de Estimação Generalizadas (EEG) (&alpha;=0,05), e teste post hoc de Bonferroni. Após análise da diferença entre as médias dos escores obtidos para QVSB e satisfação, verificou-se diferença significante, entre grupos tratados e tempo, apenas para a segunda variável. Assim, a modalidade de tratamento não interferiu na qualidade de vida dos participantes após 1 e 2 anos. Para este período, a satisfação foi maior para o grupo I (GI: 1ano - &Delta;61 mm, 2 anos - &Delta;55 mm), embora o grupo II (GII: 1 ano - &Delta;52 mm, 2 anos - &Delta; 45 mm) apresentasse valores intermediários e o grupo 3 (GIII: 1 ano 32 mm, 2 anos - 31 mm), valores aceitáveis dentro do tratamento. A taxa de sobrevivência dos implantes foi maior para o grupo de implantes regulares: GI (n=152): 88,8%; GII (n=84): 82,1% e GIII (n=80): 97,5%. Para os critérios de sucesso, os únicos parâmetros a apresentarem diferenças entre os grupos foram dor (maior frequência, GIII) e sangramento à sondagem (maior frequência, GI), apenas no 2º ano. Índice de placa, sangramento e profundidade de sondagem aumentaram com o tempo, sendo que GI e GII atingiram menor média. Conclui-se que o tratamento com overdenture, independente do tipo de implantes, teve impacto positivo na QVSB, enquanto a satisfação foi maior no grupo de quatro mini-implantes. Além disso, overdentures retidas por mini-implantes ou implantes regulares atingiram sucesso clínico em 2 anos. / Mandibular overdentures retained by mini implants have provide a good retention and lower cost, postoperative discomfort in rehabilitation of aesthetics, function and phonation. This study aimed to follow up a 2-year randomized clinical trial to compare the quality of life associated with oral health (QVSB), patient satisfaction, as well as the success rates of implants and overdentures after the installation Of mini-implants (two or four) or two conventional implants. In the initial phase, the sample consisted of 120 edentulous individuals were randomly allocated into three groups according to the treatment received: (GI) four mini-implants, (GII) two mini-implants, or (GIII) two regular implants. During follow-up of 1 and 2 years the sample was reduced to 106 and 96 participants, respectively. The QVSB, measured by the OHIP-EDENT questionnaire, and satisfaction (measured by specific questions answered in EVA 100mm) were evaluated before the intervention and after the follow-up period. Another variable used to verify the effectiveness of the treatment was the success rate of implants and overdentures, which was obtained through clinical parameters and implant survival. The groups were compared using Generalized Estimation Equations (EEG) (&alpha;= 0.05), and post hoc Bonferroni test. After analyzing the difference between the means of the scores obtained for QVSB and satisfaction, a significant difference was observed between treated groups and time, only for the second variable. Thus, the treatment modality did not interfere in the participants\' quality of life after 1 and 2 years. For this period, the satisfaction was highest for the groups of four mini-implants (GI: 1 year - &Delta;61 mm, 2 years - &Delta; 55 mm), although the two mini-implants (GII: 1 year - &Delta;52 mm, 2 years - &Delta; 45 mm) presented intermediate values and the groups of regular implants (GIII: 1 year - 32 mm, 2 years - 31 mm) had acceptable values within the treatment. The survival rate of the implants was higher for the group of conventional implants: GI (n = 152): 88.8%; GII (n = 84): 82.1% and GIII (n = 80): 97.5%. For the success criteria, the only parameters to present differences between the groups in the second year were pain and bleeding. The first occurred more frequently in the GIII while the second occurred in the GI. Peri-implant parameters (IP, SS, PS) increased with time and groups of mini-implants reached lower mean. It was concluded that overdenture treatment, regardless of the type of implant, has a positive impact on QVSB, while satisfaction was higher in the group of four mini-implants. In addition, overdentures retained by mini-implants or regular implants have achieved clinical success in 2 years.

Page generated in 0.0749 seconds