Spelling suggestions: "subject:"neuromuskulären"" "subject:"muskulär""
11 |
Reliability of countermovement jump,and isometric mid-thigh pull measurementafter a cycle ergometer VO2-max test. A pilotstudy within the frame of the Project: Relative Energy Deficit in Swedish Athletes / Reliabilitet av countermovement jump och isometriskt mid-thigh pull test efter VO2-max cykelergometertest. En pilotstudie inom ramen för projektet Relativ energibrist i svensk idrott (REI-projektet)Schiller, Jesper January 2023 (has links)
Abstract Introduction In order to evaluate aerobic, power and strength abilities coaches typically has performed all the physical tests at the same testing session. Today there is a lack of instruments tested for reliability in that kind of setting. Aim The purpose of this study was to investigate intra-session reliability for countermovement jump (CMJ) and Isometric Midthigh Pull (IMTP) after a fatiguing cycle-ergometer VO2-maxtest. Method: A quantitative, descriptive, cross-sectional study design where 25 Swedish elite athletes, 11 women (age 26.9 ± 8.3 year, weight 63.3 ± 7.4 kg, length 169.8 ± 7.4 cm and BMI 21.9 ± 1.4) and 14 men (age 23.4 ± 2.9 year, weight 77.9 ± 12.4 kg, length 179.0 ± 8.3 cm and BMI 24.2 ± 2.0), from different sports were recruited through a stratified comfort selection from the initial survey study within the project: Relative Energy Deficit in Swedish Athletes (the REI-project). The study-participants performed physical testing in one test session, the test-protocol consisted of a incremental VO2-max cycle-ergometer test to fatigue followed by 3 attempts CMJ and 3 attempts IMTP. Results The relative reliability was excellent for both CMJ and IMTP (Intraclass correlation (ICC) 0,948 and 0,983 respectively), not surprisingly due to the heterogeneous population. The absolute reliability was excellent as well (percentage of typical Error (TE%) 5,84 and 4,02, percentage of coefficient of variation (CV%) 6,81 and 7,63 respectively). Conclusion The CMJ and IMTP are intra-session reliable in measuring jump hight and isometric strength in a state of fatigue. / Abstrakt Introduktion I syfte att utvärdera såväl aerob kapacitet, spänst och styrka utför tränare ofta dessa fysiska tester vid ett och samma testtillfälle. Idag saknas det testinstrument som reliabilitetstestats i en sådan kontext.Syfte Avsikten med denna studie var att undersöka intra-session reliabiliteten i Countermovement Jump (CMJ) och Isometriskt Mid Thigh Pull (IMTP) utförda efter ett utmattande cykelergometertest för VO2-max. Metod En kvantitativ, deskriptiv, tvärsnittsstudie valdes där 25 svenska elitidrottare, 11 kvinnor (ålder 26.9 ± 8.3 år, vikt 63.3 ± 7.4 kg, längd 169.8 ± 7.4 cm and BMI 21.9 ± 1.4) och 14 män (ålder 23.4 ± 2.9 år, vikt 77.9 ± 12.4 kg, längd 179.0 ± 8.3 cm and BMI 24.2 ± 2.0), inom olika idrotter rekryterades genom ett stratifierat bekvämlighetsurval från projektet Relativ energibrist i svensk idrott (REI-projektet) initiala enkätstudie. Forskningspersonerna utförde fysiska tester vid ett tillfälle, testprotokollet bestod av ett stegrat VO2-max cykelergometertest till utmattning följt av 3 maximala försök CMJ och 3 maximala försök IMTP. Resultat Relativ reliabilitet visades utmärkt för både CMJ och IMTP (intraclass correlation (ICC) 0,948 respektive 0,983), vilket inte var förvånande med tanke på den heterogena populationen. Absolut reliabilitet visades även den vara utmärkt (typfel uttryckt i procent (TE%) 5,84 respektive 4,02 och variationskoefficient uttryckt i procent (CV%) 6,81 respektive 7,63). Slutsats CMJ och IMTP är reliabla testinstrument, intra-session, för mätning av hopphöjd och isometrisk styrka i ett utmattat tillstånd. / Projekt: Relativ energibrist i svensk idrott (REI-projektet)
|
12 |
Automatic overcurrent and leakage current sensing in multiple channel NMES systemsOtter, Malin, Jamal Pati, Bashar January 2023 (has links)
This report presents the development, implementation, and testing of a current monitor system that is specifically developed for testing a neuromuscular electrical stimulation system (NMES). The NMES system, developed by KTH and its academic and industrial partners Karolinska institute and Matrix Muscle Support, incorporates advanced features aimed at preventing cardiovascular diseases. The problem statement revolves around the necessity of developing a system capable of detecting any instances of overcurrent or leakage current in the neuromuscular electrical stimulation system. The purpose of this current monitoring system is to offer real-time monitoring of current levels within the electrical stimulation system. The project’s goal is to design and implement a comprehensive software and hardware solution that allows users to simultaneously monitor voltage levels across multiple channels and detect any abnormalities. The project was executed using a top-down approach. Each subtask is processed separately and finally tested to be verified and approved according to the expectations set. Test-driven development (TDD) methodology was employed to ensure the reliability and accuracy of the software and hardware implementation. The project has produced several significant results, the most important of which include the successful implementation of a real-time monitoring system for the multi-channel NMES system. A dedicated circuit board design has been prepared according to the specified requirements described in the report. The software interface has been designed to provide the user with real-time readings of voltage levels as well as visual identification of normal and abnormal values. The measurements carried out during all the tests gave clear answers to the set question, with the exception of some displacement (offset) which can be investigated more closely in future research. Furthermore, the reference images showed that the system was functioning in accordance with its original intended purpose. / Denna rapport presenterar utvecklingen, implementeringen och testningen av ett strömmätningssystem som är speciellt utvecklat för att testa ett neuromuskulärt elektriskt stimuleringssystem (NMES). NMES-systemet, utvecklat av KTH och dess akademiska och industriella partners Karolinska institutet och Matrix Muscle Support, innehåller avancerade funktioner som syftar till att förebygga hjärt-kärlsjukdomar. Problemformuleringen kretsar kring nödvändigheten av att utveckla ett system som kan detektera fall av överström eller läckström i det neuromuskulära elektriska stimuleringssystemet. Syftet med detta strömmätningssystem är att erbjuda realtidsövervakning av strömnivåer inom det elektriska stimuleringssystemet. Projektets mål är att designa och implementera en omfattande mjukvaru- och hårdvarulösning som tillåter användare att samtidigt övervaka spänningsnivåer över flera kanaler och upptäcka eventuella avvikelser. Projektet genomfördes med en top-down-metod. Varje deluppgift bearbetas separat och testas slutligen för att verifieras och godkännas enligt de förväntningar som satts. Testdriven utvecklingsmetod (TDD) användes för att säkerställa tillförlitligheten och noggrannheten hos implementeringen av mjukvara och hårdvara. Projektet har gett flera betydande resultat, av vilka de viktigaste inkluderar framgångsrik implementering av ett realtidsövervakningssystem för flerkanals NMES-systemet. En dedikerad kretskortsdesign har utarbetats enligt de specificerade kraven som beskrivs i rapporten. Mjukvarugränssnittet har utformats för att ge användaren realtidsavläsningar av spänningsnivåer samt visuell identifiering av normala och onormala värden. De mätningar som genomfördes under samtliga tester gav tydliga svar på frågeställningen, med undantag för viss förskjutning (offset) som kan undersökas närmare i framtida forskning. Vidare visade referensbilderna att systemet fungerade i enlighet med det ursprungliga syftet.
|
13 |
Fysisk träning inom jazzdansundervisning : en kvalitativ studie om hur jazzdanslärare beskriver utveckling av fysiologiska färdigheter i dansundervisningNyman, Satu January 2023 (has links)
This study aims to shed light on practices that jazz dance teachers have incorporated into their teaching in order to enhance development of physiological abilities, as well as examine how these practices have become part of their jazz dance teaching practise.The research was conducted through four semi-structured interviews where jazz dance teachers described how they enhance physiological abilities in their dance teaching practice, and which aspects impact their choices. The transcribed interviews were analysed using thematic analysis, supplemented by the application of selected principles for physical training. The results indicated that physiological abilities were mostly enhanced through conventional jazz dance technique training, within the conventional structural framework, and that the physiological aspect is not addressed in the early planning process, but comes along later following the progression of the dance technique training. Furthermore, the results imply that the social construction of a jazz dance training and convention have significant impact to the practices used to improve physiological abilities in jazz dance training. The conclusion is that jazz dance is recognised as a physically demanding genre, where technique training can enhance most of the physiological abilities.
|
Page generated in 0.0598 seconds