• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 263
  • 128
  • 63
  • 44
  • 10
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 676
  • 109
  • 94
  • 80
  • 57
  • 56
  • 56
  • 50
  • 49
  • 49
  • 47
  • 44
  • 43
  • 42
  • 39
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
671

En jämförande studie av två metoder för analys av tårfilmen : En pilotstudie

Edström, Ola, Gerebo, Linnéa January 2024 (has links)
Syfte: Syftet med studien var att jämföra två metoder vid undersökning av tårfilmsanalys; tårflödesbeteende-metoden och fluorescein break-up mönster och om deras mätresultat överensstämmer med varandra. Detta för att diskutera om någon av metoderna kunde vara ett bättre alternativ att adaptera ute i praktiken för vårdgivare inom ögonvården. Metod: Initialt fick deltagarna besvara en OSDI-enkät (ocular surface disease index), därefter gjordes resterande mätningar i biomikroskopet. I biomikroskopet utfördes initialt dem icke-invasiva mätningarna som tillhörde tårflödesbeteende-metoden (mätning av TMH (tårmeniskhöjd), debrishastighet efter blinkning och mätning av lipidlagrets interferensmönster) även NiBUT (non-invasive tear break-up time) utfördes. Efter dem icke-invasiva mätningarna tillsattes fluorescein i inferiora temporala fornix och dem invasiva testerna; TBUT (tear break-up time) och FBUP (fluorescein break-up mönster) utfördes tre gånger. Alla mätningar dokumenterades med video. Tre oberoende bedömningar utfördes. Studien undersökte om resultatet av tårflödesbeteendet och FBUP hade ett samband och vilken utav metoderna som fick en högre intravaliditet utefter dem bedömningar som utfördes. Resultat: Totalt deltog 26 deltagare varav 4 exkluderades. Deltagarna var mellan 19–57 år gamla med en genomsnittsålder på 35 år och en standardavvikelse på ±12,3 år. Samtliga presenterade med en OSDI ≥13, alternativt hade en visuellt frekvent blinkfrekvens. Det återfanns ett samband mellan tårflödesbeteende-metoden och FBUP i studien, dock ingen av klinisk signifikans ((bedömare 1, Cramer’s V= 0,46 p=0,06) (bedömare 2, Cramer’s V=0,33 p=0,32) (bedömare 3, Cramer’s V=0,33 p=0,34)). Tårflödesbeteende-metoden (Fleiss kappa =0,29, p=0,40) och FBUP (Fleiss kappa =0,25, p=0,40) uppvisade båda på en mindre god intra-validitet Slutsats: Det finns ett samband mellan tårflödesbeteende-metoden och FBUP men ingen statistisk signifikans. Intravaliditeten är marginellt högre vid tårflödesbeteende-metoden än vid FBUP i studien. / Aim: The aim of this study was to compare two methods used during tear-film analysis; tear-flow behaviour, and fluorescein break-up pattern and if their measured results are in an agreement. This in order to discuss which one of the methods would be more suitable to apply in clinical practice for healthcare workers in the field of optometry.  Method: Initially the participants filled out an OSDI questionnaire (ocular surface disease index), thereafter measurements were done in the biomicroscope. Initially the non-invasive measurements such as the tear-flow behaviour method (measurements of TMH (tear meniscus height), speed of debris movement across the tear film after blinking and measurements of the lipid layer interference) and NiBUT (non-invasive break-up time) were measured. Afterwards fluorescein was applied in the inferior temporal fornix and the invasive measurements; TBUT (tear break-up time) and FBUP (fluorescein break-up pattern) were measured three times. All measurements done in the biomicroscope were documented with video and three independent assessments were done. This study looked at the results from the tear-flow behaviour and FBUP and if they agreed with one another. It also looked into which one of the methods presented a higher intra-validity in regard to the assessments made. Results: The study had a total of 26 participants, of which 4 were excluded. The participants were between the ages of 19-57 years old with an average age of 35 years with a standard deviation of ±12,3 years. The participants presented with an OSDI of ≥13, with exceptions made if a participant visually had a high blink frequency. A correspondence between the tear-flow behaviour method and  FBUP could be observed, however none of statistical significance ((assessor 1, Cramer’s V= 0,46 p=0,06) (assessor 2, Cramer’s V=0,33 p=0,32) (assessor 3, Cramer’s V=0,33 p=0,34)). The intra-validity of the tear-flow behaviour method (Fleiss kappa =0,29, p=0,40) and FBUP (Fleiss kappa =0,25, p=0,40) were both categorized as weak intra-validity.  Conclusion: There is a correspondence between the tear-flow method and FBUP, without statistical significance. The intra-validity was marginally higher within the tear-flow method compared to FBUP in the study.
672

Amélioration de la justesse des modèles d’hygiène du travail utilisés pour estimer les expositions professionnelles aux vapeurs de solvants

Abattan, Spéro Franck Aimé 09 1900 (has links)
Contexte : Les modèles physico-chimiques sont de plus en plus utilisés en hygiène du travail pour estimer l’exposition aux contaminants chimiques de l’air. Ils prédisent l’exposition à l’aide d’équations mathématiques qui relient les caractéristiques de l'émission des contaminants et leur dispersion dans l'air aux concentrations qui en résultent. La mise en œuvre de ces modèles est rapide, moins coûteuse que l’échantillonnage de l’air, et particulièrement indiquée pour les évaluations d'expositions passées et/ou futures. Les estimations de ces modèles, quoique généralement satisfaisantes, peuvent être, dans certains cas, biaisées du fait des incertitudes associées à l’estimation des paramètres d'entrée, notamment, le taux d'émission des contaminants, qui peut être particulièrement difficile à estimer. Objectifs : L’objectif principal de cette thèse était de proposer des améliorations aux modèles physico-chimiques utilisés en hygiène du travail afin de permettre des estimations plus fiables des concentrations de solvants dans l’air des milieux de travail. Trois objectifs spécifiques étaient définis pour l’étude : (1) effectuer une revue critique de la littérature existante sur le modèle à deux compartiments ; (2) améliorer l’estimation du taux d’émission des contaminants en situations de petits déversements de solvants organiques purs ou de mélanges idéaux de solvants ; (3) améliorer l’estimation du taux d’émission des contaminants en situations de petits déversements de mélanges non-idéaux de solvants organiques. Méthodes : Pour le premier objectif, une revue documentaire des publications scientifiques ayant utilisé le modèle à deux compartiments pour évaluer l'exposition aux vapeurs de solvants a été effectuée. Les données d’exposition (scénarios, solvants, conditions d’études), de modélisation (paramètres d’entrée, résultats) et d’évaluation des performances prédictives du modèle ont été compilées et analysées afin d’identifier les forces et les facteurs potentiels d’amélioration du modèle. Pour le deuxième objectif, trois équations d’estimation des constantes de taux d'évaporation de contaminants alphas (α) ont été développées, en se basant sur des modèles de régression statistiques mettant en relation des alphas expérimentaux mesurés pour cinq solvants purs lors de 183 tests d’évaporation simulant des petits déversements de solvants, et divers déterminants de alpha étudiés. La capacité prédictive des trois équations a été évaluée en comparant les alphas estimés avec des données expérimentales internes et externes à l’étude. Pour le troisième objectif, deux équations dérivées de la Loi de Raoult ont été proposées pour estimer les constantes de taux d'évaporation alphas lors de petits déversements de 12 mélanges aqueux binaires non-idéaux de solvants, en corrigeant ou non, pour la non-idéalité des mélanges. Les concentrations atmosphériques de contaminants, corrigées ou non, ont été prédites à l’aide d’un modèle de petit déversement proposé par le logiciel IHMOD. La qualité des estimations du modèle a été évaluée en comparant, graphiquement et numériquement, les concentrations prédites corrigées ou non, avec des mesures de concentrations réelles. Résultats : Pour le premier objectif, la revue de littérature a démontré l’efficacité du modèle à deux compartiments pour l’évaluation des expositions chimiques sur la base de ses performances de prédiction qui étaient globalement dans un facteur de 0,3 à 3,7 fois les concentrations réelles avec 93 % des valeurs comprises entre 0,5 et 2. Le modèle surestimait les concentrations réelles dans 63 % des évaluations, ce qui témoigne de son utilité à faire prendre, généralement, des décisions conservatrices au profit des travailleurs. L’estimation adéquate des paramètres d’entrée, notamment, du taux d’émission des contaminants, et l’inclusion d’autres facteurs influents tels que la géométrie de la source d’émission, le type et la position du système de ventilation, la présence et l’orientation du travailleur dans une pièce, ont été identifiés parmi les points majeurs d’amélioration du modèle. Pour le deuxième objectif, les alphas expérimentaux mesurés pour les cinq solvants purs variaient entre 0,002 et 0,448 min-1 avec une moyenne de 0,076 min-1. Les principaux déterminants de alpha identifiés étaient la pression de vapeur du solvant, le volume de solvant déversé, la surface de déversement, le ratio de surface de déversement/volume de déversement, la vitesse d’air au-dessus du déversement et la forme du récipient de déversement. Les trois équations développées dans notre étude ont prédit les alphas expérimentaux externes avec un degré élevé d'exactitude et de précision. Les pourcentages moyens d'erreur étaient de –32,9, –32,0 et –25,5 %, respectivement, avec des écarts-types associés aux pourcentages moyens d'erreur de 17,7, 33,3 et 26,0 %, respectivement, et des R2 de 0,92, 0,65 et 0,87, respectivement. Pour le troisième objectif, concernant l’évaluation des mélanges de solvants, les alphas estimés corrigés pour la non-idéalité des mélanges (médiane = 0,0318 min-1) étaient supérieurs à ceux non corrigés (médiane = 0,00632 min-1). Les concentrations modélisées en utilisant les alphas corrigés concordaient raisonnablement avec les concentrations mesurées, avec un ratio médian des concentrations maximales prédites/mesurées de 0,92 (0,81 à 1,32) et une différence médiane entre les temps d’atteinte des concentrations maximales prédites et mesurées de –5 min. Sans correction pour la non-idéalité, le ratio médian des concentrations maximales prédites/mesurées était de 0,31 (0,08 à 0,75) et la différence médiane entre les temps d’atteinte des concentrations maximales prédites et mesurées était de +33 min, ce qui démontre l’importance de considérer la non-idéalité des mélanges lors du processus d’estimation des expositions aux mélanges non-idéaux de solvants. Conclusion : Cette thèse a permis de développer une base de données de scénarios d'exposition et de valeurs des paramètres d'entrée du modèle à deux compartiments, de même que, des équations pratiques et performantes pour estimer des taux d’émission de contaminants en situations de petits déversements de solvants purs ou de mélanges de solvants. En cela, nos résultats constituent un renforcement quantitatif et qualitatif des outils de modélisation existants et une avancée dans l'amélioration des modèles physico-chimiques utilisés en hygiène du travail pour estimer les expositions chimiques. / Context : Physico-chemical models are increasingly used in occupational hygiene to estimate airborne contaminant concentrations. They predict exposure concentrations through mathematical equations that relate the characteristics of the contaminants’ mass emission and their dispersion in the air to the resulting concentrations. These models are quick to use, low cost, and exclusively indicated for past and/or future exposure assessments. Their estimates have been shown to be, generally, in a good agreement with actual air contaminant concentrations. But, sometimes, these models’ outcomes can be substantially biased due to the uncertainty associated with the estimation of the input parameters, notably, the contaminant mass emission rate, which can be particularly challenging to estimate. Objectives : The main objective of this thesis was to propose some improvements to the physico-chemical models used in occupational hygiene in order to allow for more reliable estimates of solvents’ concentrations in the air of the workplaces. Three specific objectives were defined for the study : (1) to perform a critical review of the existing literature on the two-zone model; (2) to improve the estimation of the contaminants’ mass emission rate in exposure scenarios involving small spills of pure organic solvents or ideal solvent mixtures; (3) to improve the estimation of the contaminants’ mass emission rate in exposure scenarios involving small spills of non-ideal organic solvent mixtures. Methods : For the first objective, a literature review based on scientific publications that used the two-zone model to assess exposures to solvent vapours was performed. Data on the exposures (scenarios, solvents, study conditions), the modeling processes (input parameters, results) and on the predictive performance of the model were compiled and analyzed to identify the strengths and the potential areas for the improvement of the model. For the second objective, three equations for estimating the contaminants evaporation rate constants alphas (α) were developed, based on statistical regression models, relating experimental alphas measured for five pure organic solvents during 183 evaporation tests simulating small spills of solvents, and various determinants of alpha. The predictive ability of the three equations was assessed by comparing the estimated alphas with both internal and external experimental measured alphas. For the third objective, two equations derived from Raoult's Law were proposed to estimate the contaminants evaporation rate constants alphas during small spills of 12 non-ideal binary aqueous mixtures, correcting or not for the non-ideality of the mixtures. Corrected and non-corrected air contaminants concentrations were predicted using a small spill model proposed by the IHMOD modeling tool. The quality of the model estimates was assessed by comparing, graphically and numerically, the corrected and non-corrected predicted contaminants concentrations to measured contaminants concentrations. Results : For the first objective, the literature review demonstrated the effectiveness of the two-zone model for assessing chemical exposures based on its predictive performance which was globally within a factor of 0.3 to 3.7 times the actual concentrations, with 93 % of the values being between 0.5 and 2. The model overestimated the actual concentrations in 63 % of the evaluations, which underlines the usefulness of the model for, generally, leading to make conservative decisions that would be beneficial to the workers. The adequate estimation of input parameters, notably, the contaminant mass emission rate, and inclusion of other influential factors such as the geometry of the emission source, the type and position of the ventilation system, the presence and orientation of a worker in a room were the major avenues identified for the improvement of the model. For the second objective, the measured experimental alpha values varied from 0.002 to 0.448 min-1 with an average value of 0.076 min-1. The main determinants identified for alpha were the vapor pressure of the solvent, the spill volume, the spill surface area, the spill surface area-to-spill volume ratio, the air speed above the spill, and the shape of the spill container. The three equations developed in our study predicted the external experimental alphas with a high degree of accuracy and precision. The mean percentages of error were –32.9, –32.0 and –25.5 %, respectively, with associated standard deviations of the percentages of error of 17.7, 33.3 and 26.0 %, respectively, and associated R2 of 0.92, 0.65 and 0.87, respectively. For the third objective, regarding the evaluations of the solvent mixtures, the estimated alpha values which were corrected for the non-ideality of the mixtures (median = 0.0318 min-1) were higher than those which were not corrected (median = 0.00632 min-1). Modeled concentrations using the corrected alphas reasonably agreed with measured concentrations, with a median predicted peak concentrations-to-measured peak concentrations ratio of 0.92 (0.81 to 1.32) and a median difference between the predicted and the measured peak times of –5 min. Without correction for non-ideality, the median predicted peak concentrations-to-measured peak concentrations ratio was 0.31 (0.08 to 0.75) and the median difference between the predicted and the measured peak times was +33 min, which demonstrates the importance of accounting for the non-ideality effect during the process of estimating exposures related to non-ideal solvent mixtures. Conclusion : In this thesis, we developed a database of exposure scenarios and values for the input parameters of the two-zone model, as well as, new practical and efficiently robust equations for estimating contaminants’ mass emission rates in exposure scenarios involving small spills of pure and mixed volatile liquids. Our results constitute a quantitative and qualitative reinforcement of the existing modeling tools and a step further in the improvement of the physico-chemical models used in occupational hygiene to estimate chemical exposure levels.
673

Analytical method development for the identification, detection, and quantification of emerging environmental contaminants in complex matrices

Place, Benjamin J. 15 August 2013 (has links)
The development of analytical methods for emerging contaminants creates many unique challenges for analytical chemists. By their nature, emerging contaminants have inherent data gaps related to their environmental occurrence, fate, and impact. This dissertation is a compilation of three studies related to method development for the structural identification of emerging contaminants, the detection and quantification of chemicals used in unprecedented quantities and applications, and the extraction of compounds from complex matrices where the solvent-solute-matrix interactions are not completely understood. The three studies present analytical methods developed for emerging contaminants in complex matrices, including: fluorochemical surfactants in aqueous film-forming foams, oil dispersant surfactants in seawater, and fullerene nanomaterials in carbonaceous solids. Aqueous film-forming foams, used in military and commercial firefighting, represent environmentally-relevant commercial mixtures that contain a variety of fluorochemical surfactants. Combining the surfactant-selective ionization of fast atom bombardment mass spectrometry with high resolution mass spectrometry, chemical formulas for 11 different fluorochemical classes were identified. Then AFFF-related patents were used to determine the structures. Of the eleven classes of fluorochemicals, ten have little, if any, data on their environmental occurrence, fate, and potential impacts in the peer-reviewed literature. In addition, nine of the identified classes had either cationic or zwitterionic functionalities and are likely to have different transport properties compared to the well-studied anionic fluorochemicals, such as perfluorooctanoate. After the Deepwater Horizon oil spill in the summer of 2010, one of the emergency response methods for the mitigation of the oil's environmental impact was the use of unprecedented amounts of oil dispersant to break down the oil slick and encourage biodegradation. This event illustrated the need for rapid analytical method development in order to respond to the potential environmental disaster in a timely manner. Using large volume injection liquid chromatography with tandem mass spectrometry, an analytical method was developed for the trace analysis of the multiple dispersant surfactant classes and the potential degradation products of the primary surfactant. Limits of detection ranged from 49 ��� 3,000 ng/L. The method provided excellent recovery (86 ��� 119%) and precision (10 ��� 23% RSD), while also accommodating for the high salinity of seawater samples and analyte contamination. Despite the fact that fullerene nanomaterials have been studied for almost three decades, research is still being conducted to fully understand the environmental properties of these materials. Previous studies to extract fullerenes from environmental matrices have resulted in low efficiency, high variability, or the extraction efficiencies have gone unreported. Extraction by ultrasonication with toluene and 1-methylnaphthalene increased the recovery 5-fold of a spiked, isotopically-labeled C������ surrogate from carbon lampblack as compared to that of the conventional approach of extracting with 100% toluene. The study revealed the importance of evaluating experimental variables such as extraction solvent composition and volume, and sample mass, as they have a significant impact on the quantitative extraction of fullerenes from environmental matrices. / Graduation date: 2013 / Access restricted to the OSU Community at author's request from Aug. 15, 2012 - Aug. 15, 2013
674

Entwicklung eines miniaturisierten Fluoreszenzsensors basierend auf molekular geprägten Polymeren / Development of a miniaturized fluorescence sensor based on molecularly imprinted polymers

Kunath, Stephanie 03 June 2013 (has links) (PDF)
Die vorliegende Arbeit befasst sich mit der Entwicklung von Biosensoren mit dem Ziel, mit Hilfe der Kopplung molekular geprägter Polymere (MIPs) als neuartiges Rezeptormaterial und dem sensitiven Nachweisprinzip der Fluoreszenz eine neue Qualität des Analytnachweises zu erreichen. Es wurde eine neue Strategie zur Optimierung der Bindungseigenschaften von molekular geprägten Polymeren in wässrigen Lösungsmitteln entwickelt, die die Kopplung aus Design of Experiments und der Optimierung multipler Zielgrößen umfasst. Damit konnten die Polymerbindungseigenschaften für alle vier betrachteten Parameter wesentlich verbessert werden. Mit Hilfe stationärer und zeitaufgelöster Fluoreszenztechniken wurde die Aufklärung der Wechselwirkung zwischen MIP und Analyt auf molekularer Ebene sowie die Charakterisierung einer neuen Nachweisstrategie basierend auf einen Förster-Resonanzenergietransfer-Mechanismus realisiert. Es wurde ferner ein MIP-Sensor für biologische Proben mit mikrofluidischer Probenzuführung aufgebaut und mittels Fluoreszenzspektrometer als konventionelles Nachweisverfahren etabliert. Darauf aufbauend wurde der optische Nachweis miniaturisiert und somit miniaturisierte Lichtquellen und Detektoren sowie eine faser-optische Lichtleitung eingesetzt. Davon ausgehend erfolgte die Optimierung des Messaufbaus hinsichtlich der Sensitivität und Nachweisgrenze des fluoreszierenden Analyten. Schließlich wurden erstmalig fluoreszenzmarkierte MIP-Partikel zur Lokalisation und Quantifizierung auf Zelloberflächen eingesetzt, d.h. diese dienten als Antikörperersatz der Immunfärbung. / This thesis deals with the development of biosensors with the aim to couple molecularly imprinted polymers (MIPs) as new receptor material with the sensitive detection principle of fluorescence in order to improve analyte detection. A new strategy for optimization of binding parameters of molecularly imprinted polymers in aqueous media was developed which is based on the coupling of design of experiments and the optimization of multiple objective parameters. Due to that the polymer binding properties for all four considered parameters could be optimized considerably. With the help of steady state and time-resolved fluorescence techniques the interaction between MIP and analyte could be clarified on a molecular basis. Furthermore the characterization of a new detection strategy based on a Förster resonance energy transfer mechanism was realized. Moreover a MIP sensor with microfluidic sample handling for biological samples was built-up and established with fluorescence spectroscopy as conventional detection method. Based on that, the optical detection was miniaturized with respect to light sources, detectors as well as optical fibers for light guidance. This set-up was optimized concerning sensitivity and limit of detection of the fluorescent analyte. Finally, for the first time fluorescently marked MIP particles were applied for imaging on cell surfaces – meaning that they were used for immunostaining as antibody mimics.
675

Caractérisations chimiques et biologiques d’extraits de plantes aromatiques et médicinales oubliées ou sous-utilisées de Midi-Pyrénées (France) et de Chongqing (Chine) / Chemical and biological characterisation of extracts from forgotten or underutilised medicinal and aromatic plants from Midi-Pyrénées (France) and Chongqing (China) regions

Zhao, Tianming 12 May 2014 (has links)
Les régions de Midi-Pyrénées (France) et de Chongqing (Chine) sont riches en plantes aromatiques et médicinales dites oubliées (ou médiévales). Afin de valoriser pleinement les différentes bio-molécules extractibles de ces plantes, le concept de MAP-raffinerie a été créé et appliqué à une sélection de plantes issues de ces deux régions. Plusieurs technologies d’extraction utilisant l’eau comme solvant vert (hydrodistillation, distillation à la vapeur et extraction par eau sub-critique) ont ainsi été employées et leur impact tant sur la composition des huiles essentielles que sur la récupération des molécules anti-oxydantes a été évalué. Dans un premier temps, une liste de plantes aromatiques et médicinales oubliées, voire sous-utilisées dans les deux régions a été établie selon des règles de sélection prédéfinies. Six plantes modèles de la région de Midi-Pyrénées (Tussilago farfara L., Calendula arvensis L., Robinia pseudoacacia L., Geranium robertianum L., Cytisus scoparius L. et Spartium junceum L.) et trois plantes de la région de Chongqing (Tussilago farfara L., Citrus aurantium L. et Saussurea costus) ont finalement été retenues. Puis, le concept de MAP-raffinerie a été appliqué à ces plantes afin d’étudier leur possible valorisation globale. L’étude des compositions chimiques des extraits volatils des racines de Tussilago farfara L. et de Calendula arvensis L., ainsi que des boutons de fleurs de Spartium junceum L. a été réalisée par GC et GC-MS pour la première fois. Les principaux composés chimiques dans l’extrait volatil de racines de Tussilago farfara L. étaient des hydrocarbures sesquiterpéniques et des composés aliphatiques tandis que les principaux composés chimiques dans l’extrait volatil de racines de Calendula arvensis L. étaient des sesquiterpènes oxygénés, des monoterpènes oxygénés et des diterpènes oxygénés. L’extrait volatil de boutons de fleurs de Spartium junceum L. était principalement composé de composés aliphatiques. Par ailleurs, les résultats de l’évaluation des capacités anti-oxydantes des extraits (par les tests DPPH, ABTS, FRAP, ORAC et Folin-Ciocalteu) ont montrés que plusieurs plantes comme Cytisus scoparius L., Tussilago farfara L., Citrus aurantium L. ou Robinia pseudoacacia L. pourraient être des sources potentielles d’anti-oxydants naturels. D’un point de vue technologique, les comparaisons de l’utilisation de l’hydrodistillation (HD), de la distillation à la vapeur (SD) et de l’extraction par eau sub-critique (SWE) ont montrées que si la HD et la SD ont des effets limités sur la composition des huiles essentielles, la HD semble être une méthode plus efficace pour la récupération des composés anti-oxydants à partir des résidus de distillation que la SD tandis que la SWE s’avère être une technologie prometteuse pour l’extraction directe de ces molécules à partir des plantes. Si la composition minérale de l’eau lors de l’hydrodistillation n’a que des effets très limités sur les rendements d’extraction, les teneurs en ions calcium et bicarbonate des eaux ont par contre des effets décroissants significatifs sur la capacité anti-oxydante et sur la teneur phénolique totale des extraits aqueux et méthanoliques. Au vue de ces résultats, un concept amélioré de MAP-raffinerie a été développé en intégrant une extraction à l’eau sub-critique pour l’extraction des composés anti-oxydants des résidus d’extraction primaire. Selon ce nouveau concept, cinq extraits peuvent être obtenus à partir des matières végétales: un extrait volatil, un extrait aqueux, un extrait méthanolique, un extrait à l’eau sub-critique et in fine un résidu solide. Les premiers résultats ont montrés que la "MAP-raffinerie améliorée" augmente de manière significative la récupération des antioxydants par rapport à la MAP-raffinerie originale et permet d’envisager une valorisation plus facile du résidu solide en agro-matériaux du fait de sa faible teneur en eau résiduelle. / In both Midi-Pyrénées region (France) and Chongqing region (China), there are rich and underutilized medicinal and aromatic plants (MAP). Aiming at fully exploiting different molecules in these plants, the concept of MAP-refinery was developed and applied to several underutilized medicinal and aromatic plants in these two regions. Several water-based green extraction technologies of natural products (e.g. hydrodistillation, steam distillation and subcritical water extraction) were also investigated to look at their effects on essential oil composition and antioxidants recovery from selected plants. Firstly, lists of forgotten or underutilized medicinal and aromatic plants in both regions were established according to the rules of selection. From the lists, six plants in the Midi-Pyrénées region (Tussilago farfara L., Calendula arvensis L., Robinia pseudoacacia L., Geranium robertianum L., Cytisus scoparius L. and Spartium junceum L.) and three plants in the Chongqing region (Tussilago farfara L., Citrum aurantium L. and Saussurea costus) were finally selected for investigations. Then the MAP-refinery was applied to the selected plants in two regions in order to realise their global valorisation. Volatile extracts composition in the roots of Tussilago farfara L. and Calendula arvensis L., as well as flower buds of Spartium junceum L. were firstly investigated. The main chemical compounds in volatile extract from Tussilago farfara L. roots were sesquiterpene hydrocarbons and aliphatic compounds while main chemical compounds in volatile extract from Calendula arvensis L. roots were oxygenated sesquiterpenes, oxygenated monoterpenes and oxygenated diterpenes. The volatile extract from flower buds of Spartium junceum L. was mainly composed of aliphatic compounds. Antioxidant capacity evaluation results (by DPPH, ABTS, FRAC, ORAC and Folin-Ciocalteu tests) showed that several plant samples like Cytisus scoparius L., Tussilago farfara L., Citrum aurantium L. and Robinia pseudoacacia L. could be potential sources of natural antioxidants. Comparisons of hydrodistillation (HD), steam distillation (SD) and subcritical water extraction (SWE) showed that HD and SD had limited effects on essential oil composition but HD, SD and SWE had significant impacts on the recovery of antioxidants. Hydrodistillation seemed to be a better method for recovery of antioxidant compounds from residues of distillation than steam distillation. However, SWE appeared to be a more efficient method for direct extraction of antioxidant molecules (or phenolic compounds) from plants. In the hydrodistillation process, mineral contents in water were found to have very limited effects on yields of extracts but calcium and bicarbonate ions, had significant decreasing effects on antioxidant capacity and total phenolic content of both aqueous and methanolic extracts. Finally, an improved MAP-refinery was developed. Subcritical water was used for further extraction of antioxidant compounds from residues in original MAP-refinery. In this way, five parts could be obtained from plant materials: volatile extract, aqueous extract, methanolic extract, subcritical water extract and the final residue. The results showed that the improved MAP-refinery significantly increased the recovery of antioxidants compared with original MAP-refinery. This promising process will also allow a better valorisation of the final solid residue due to the lower content of residual water.
676

Entwicklung eines miniaturisierten Fluoreszenzsensors basierend auf molekular geprägten Polymeren

Kunath, Stephanie 18 February 2013 (has links)
Die vorliegende Arbeit befasst sich mit der Entwicklung von Biosensoren mit dem Ziel, mit Hilfe der Kopplung molekular geprägter Polymere (MIPs) als neuartiges Rezeptormaterial und dem sensitiven Nachweisprinzip der Fluoreszenz eine neue Qualität des Analytnachweises zu erreichen. Es wurde eine neue Strategie zur Optimierung der Bindungseigenschaften von molekular geprägten Polymeren in wässrigen Lösungsmitteln entwickelt, die die Kopplung aus Design of Experiments und der Optimierung multipler Zielgrößen umfasst. Damit konnten die Polymerbindungseigenschaften für alle vier betrachteten Parameter wesentlich verbessert werden. Mit Hilfe stationärer und zeitaufgelöster Fluoreszenztechniken wurde die Aufklärung der Wechselwirkung zwischen MIP und Analyt auf molekularer Ebene sowie die Charakterisierung einer neuen Nachweisstrategie basierend auf einen Förster-Resonanzenergietransfer-Mechanismus realisiert. Es wurde ferner ein MIP-Sensor für biologische Proben mit mikrofluidischer Probenzuführung aufgebaut und mittels Fluoreszenzspektrometer als konventionelles Nachweisverfahren etabliert. Darauf aufbauend wurde der optische Nachweis miniaturisiert und somit miniaturisierte Lichtquellen und Detektoren sowie eine faser-optische Lichtleitung eingesetzt. Davon ausgehend erfolgte die Optimierung des Messaufbaus hinsichtlich der Sensitivität und Nachweisgrenze des fluoreszierenden Analyten. Schließlich wurden erstmalig fluoreszenzmarkierte MIP-Partikel zur Lokalisation und Quantifizierung auf Zelloberflächen eingesetzt, d.h. diese dienten als Antikörperersatz der Immunfärbung. / This thesis deals with the development of biosensors with the aim to couple molecularly imprinted polymers (MIPs) as new receptor material with the sensitive detection principle of fluorescence in order to improve analyte detection. A new strategy for optimization of binding parameters of molecularly imprinted polymers in aqueous media was developed which is based on the coupling of design of experiments and the optimization of multiple objective parameters. Due to that the polymer binding properties for all four considered parameters could be optimized considerably. With the help of steady state and time-resolved fluorescence techniques the interaction between MIP and analyte could be clarified on a molecular basis. Furthermore the characterization of a new detection strategy based on a Förster resonance energy transfer mechanism was realized. Moreover a MIP sensor with microfluidic sample handling for biological samples was built-up and established with fluorescence spectroscopy as conventional detection method. Based on that, the optical detection was miniaturized with respect to light sources, detectors as well as optical fibers for light guidance. This set-up was optimized concerning sensitivity and limit of detection of the fluorescent analyte. Finally, for the first time fluorescently marked MIP particles were applied for imaging on cell surfaces – meaning that they were used for immunostaining as antibody mimics.

Page generated in 0.6777 seconds