• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 92
  • 21
  • 5
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 131
  • 103
  • 101
  • 70
  • 58
  • 51
  • 44
  • 38
  • 37
  • 23
  • 21
  • 21
  • 20
  • 20
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Infiltração bacteriana em canais radiculares obturados com diferentes cimentos endodônticos e duas técnicas obturadoras / Bacterial leakage in root canals filled with different endodontic sealers and two techniques

Cunha, Thais Vieira Rizzo Nunes da 27 June 2011 (has links)
O objetivo deste estudo foi avaliar ex vivo a infiltração do Enterococcus faecalis em canais radiculares obturados com os cimentos endodônticos AHPlus, RealSeal e o cimento experimental Sealepox, pelas técnicas da condensação lateral e compactação vertical. Cem dentes humanos unirradiculados, com canais únicos e retos, tiveram os mesmos instrumentados, e após, as coroas removidas, para a realização das obturações. Aparatos específicos para a fixação das raízes foram confeccionados contendo meio de cultura estéril e específico para a bactéria, em questão. A inoculação deEnterococcus faecalis foi realizada e, durante 60 dias, o meio de cultura foi checado diariamente para constatar sua possível turvação, o que, caracterizaria a passagem bacteriana pela obturação. Todos os espécimes foram processados histologicamente e corados pela técnica de Brown e Brenn para exame em microscópio óptico, para constatação da presença e localização do Enteroccocus faecalis no interior dos canais radiculares e na massa dentinária. Considerando a metodologia da infiltração bacteriana, os resultados obtidos mostraram que nem os cimentos obturadores e nem as técnicas foram capazes de impedir a infiltração. Contudo, a mesma ocorreu em um pequeno número de espécimes, não sendo observadas diferenças significantes entre os cimentos e técnicas. Em relação à análise microscópica, foi observada a presença dos micro-organismos em, praticamente, todos os espécimes analisados. Tal observação permite afirmar que a metodologia da infiltração bacteriana não é confiável para se qualificar o selamento proporcionado por obturações de canais radiculares. / The aim of this study was to assess ex-vivo the leakage of Enterococcus faecalis in root canals filled with endodontic sealers AHPlus, RealSeal and the experimental sealer Sealepox, after the lateral condensation or warm vertical condensation techniques. One hundred single rooted extracted human teeth had their root canals instrumented and their crowns removed for the conducting of the obturation. An experimental bacterial leakage setup was designed for fixing the root canal in the contained media, sterile and specific for the bacteria in study. The inoculation with Enterococcus faecalis was conducted and for 60 days the media was checked daily for possible change in its clear aspect, which would than, characterize the contamination by the bacteria through the root canal. All the sample which were infiltrated, totally or not, were processed and colored by the Brown and Brenn technique for observation of presence and location of Enterococcus faecalis in the root canal or dentinal tubules. With the methodology for bacterial leakage considered, the results obtained showed that none of the sealer neither the techniques employed were able to avoid leakages. Nevertheless, leakage happened in a small number of samples, where no statistical difference could be found between sealers and techniques. In regards to the microscopy analysis, presence of microorganisms was observed in practically all the samples. Such an observation, suggests that bacterial leakage is not a trustworthy indicator for qualifying sealing obtained by sealers in root canals.
42

Análise da interface de adaptação de diferentes materias obturadores resinosos / Analysis of adaptation interface from different resin filling materials

Vitoriano, Marcelo de Morais 25 June 2013 (has links)
Neste trabalho foi avaliado microscopicamente a interface de adaptação entre diferentes cimentos obturadores resinosos e dentina no interior do canal radicular de pré-molares humanos, identificando microscopicamente o nível de adaptação. Foram selecionadas 60 raízes de dentes uniradiculados, raízes retilíneas, com anatomia circular ou ovalada, ápices completos, obtidos por meio de doação feita por Cirurgião Dentistas e, consentidos seu emprego em pesquisas pelo paciente. Posteriormente as raízes foram divididas randomicamente em três grupos de acordo com o sistema de obturação empregado: Grupo 1 Guta-percha + cimento AHPlus; Grupo 2 Real Seal; Grupo 3 Sistema obturador smart-seal. Em seguida cada espécime recebeu cortes transversais em diferentes níveis, com 2mm de espessura, com disco diamantado, em máquina de corte de tecido duro (Isomet®) sob abundante irrigação. Após a realização dos cortes, as fatias a 2mm, 4mm, 6mm e 8mm foram analisadas em esteriomicroscópio, observando-se a área de adaptação cimento-dentina e em microscópio confocal para analisar a penetração do cimento em túbulos dentinários e a presença de fendas. As imagens obtidas foram analisadas pelo software de medida de área Image J®, em que as imagens foram devidamente calibradas. Os resultados apontaram uma superioridade do sistema Smart-seal na área de cimento no corte de 6mm (p<0,05), contudo uma inferioridade no que se tratou da penetração do cimento em túbulos dentinários nos cortes de 2mm, 6mm e 8mm (p<0,05). Em relação as fendas o smart-seal apresentou uma menor quantidade de fendas (p<0,05) apenas na medida de 8mm. Concluiu-se que apesar de sofrer expansão na tomada de presa, e melhor adaptação nas paredes do canal o sistema Smart Seal não apresentou penetrabilidade tubular satisfatória. / This study evaluated microscopically the interface adaptation between sealer and dentin within the root canal, identifying the level of sealing provided by different resin filling materials. 60 single rooted teeth were selected, roots straight with circular or oval anatomy, complete apexes, obtained through donation made by Surgeon Dentists and consented to its use in research by the patient. Subsequently the roots were randomly divided into three groups according to the system obturation: group 1 - Gutta-percha + cement AHPlus, Group 2 - Epiphany + Resilon, Group 3 - Smart Seal obturation system. Then each specimen received a transverse cut with 2 mm thick, with a diamond disc, cutting machine for hard tissue (Isomet ®) under abundant irrigation. After the cuts, slices to 2mm, 4mm, 6mm and 8mm were analyzed by esteriomicroscopy, observing the adaptation area between dentin and sealer, confocal microscopy was utilized to examine the penetration of cement into the dentinal tubules and the presence of gaps. The images were analyzed by software measurement area Image J ®, where the images have been properly calibrated. The results showed a superiority of Smart-seal in the area of cement in cutting 6mm (p <0.05), however inferiority in the penetration of the sealer into the dentinal tubules in sections of 2mm, 6mm and 8mm (p <0.05). Regarding the cracks Smart Seal had a smaller amount of cracks (p <0.05) only the extent of 8mm. It was concluded that although the Smart Seal system presentes expansion and better fit into the dentin walls of the canal, the system showed no satisfactory tubular penetration.
43

Avaliação in vitro do selamento apical produzido a partir de duas técnicas de aplicação de trióxido mineral agregado (MTA), em retro-preparos de raízes apicectomizadas. / In vitro evaluation of apical sealing ability produced from two mineral trioxide aggregate (MTA) placement techniques, in resected apical roots preparations.

Manicardi, Cid Alonso 11 May 2005 (has links)
O propósito deste estudo foi avaliar se o selamento promovido pelo MTA quando utilizado como material retrobturador seria diferente se inserido por duas diferentes técnicas de aplicação e condensação. 45 incisivos superiores humanos foram divididos em 3 grupos de 15 espécimes cada. Após apicectomia e preparo apical com ultra-som, as cavidades foram preenchidas com MTA, aplicado e condensado manualmente (G I) ou por vibração ultra-sônica (G II e G III). O grupo G II recebeu o MTA com o ápice posicionado para cima e o grupo G III com o ápice para baixo a fim de verificar possíveis interferências gravitacionais. Após a obturação retrógrada, os espécimes foram avaliados por infiltração linear e por área, valendo-se do corante Rodamina B a 1%. A utilização da vibração ultra-sônica para aplicação do MTA no grupo G II resultou em infiltração significativamente menor do que a ocorrida do grupo G I. Houve também diferença estatística entre os grupos da técnica ultra-sônica, com ápice voltado para cima (G II) e para baixo (G III), o que demonstra haver influência gravitacional (p < 0,05). Tal diferença não foi detectada entre os grupos G I e G III. Diante dos resultados, o ultra-som pode ser considerado como um método alternativo de aplicação do MTA. / The purpose of this study was to evaluate if the sealing ability produced by MTA, when used as a root-end filling material, would differ when used by two different placement and condensation methods. 45 human superior incisors were divided into 3 groups of 15 specimens each. After root-end resection, they were prepared with ultrasonic instrumentation and preparations were filled with MTA, placed and condensed by hand (G I) or ultrasonic methods (G II and G III). The G III group had the apical portion upside down, to verify if gravity forces could interfere in the results.After retrograde obturation the specimens were evaluated by Rhodamine B 1% for linear and area dye leakage. The MTA ultrasonic vibration in the G II group resulted in a less dye leakage than in the G I group. There was statistical difference between ultrasonic methods with the apex upside up (G II) and upside down (G III) which demonstrate a gravitational influence in sealing ability (p < 0,05). This difference wasn’t detected between G I and G III groups. At this time ultrasonic condensation should be considered as an alternative method for MTA placement.
44

Avaliação quantitativa e qualitativa da extrusão apical em técnicas de obturação termoplastificada. / Quantitative and qualitative evaluation of the apical extrusion in techniques of thermoplasticized obturation.

Strefezza, Fábio 29 March 2004 (has links)
Atualmente, as técnicas de obturação com guta-percha termoplastificada têm mostrado eficiência na adaptação dos materiais obturadores às paredes do sistema de canais radiculares, promovendo um selamento tridimensional. Porém, com a utilização destas técnicas, há dificuldade no controle longitudinal durante a obturação, que poderia acarretar em extrusão do material obturador em direção aos tecidos perirradiculares, influenciando na reparação pós tratamento endodôntico. Assim, o propósito deste estudo foi avaliar in vitro a extrusão apical de quatro técnicas de obturação termoplastificada, Thermafil, Obtura II, Ultrafil 3D e Fusionada, através de uma nova metodologia de mensuração de volume do material obturador extruído, relacionando com a freqüência da extrusão visual de guta-percha e/ou cimento e a qualidade radiográfica final da obturação. Os resultados demonstraram que a metodologia do sistema de mensuração foi efetiva para quantificar o volume de material obturador extruído, constatando extrusão em todas as técnicas termoplastificadas empregadas neste estudo, porém, quantitativamente, os grupos experimentais não apresentaram diferenças estatisticamente significantes entre as médias de volumes. Na avaliação radiográfica da qualidade final das obturações termoplastificadas, há evidências de que a técnica Obtura II produziu obturações endodônticas com qualidades estatisticamente inferiores às demais técnicas. De modo geral, podemos considerar que as técnicas Thermafil, Ultrafil 3D e Fusionada apresentaram resultados semelhantes em relação ao volume do material obturador extruído e qualidade radiográfica final da obturação, enquanto que as técnicas Thermafil e Fusionada exibiram resultados mais favoráveis em relação à freqüência da extrusão visual de guta-percha e/ou cimento. / In the present, the obturation techniques with termoplasticized gutta-percha have been proving efficiency in adaptation of the filling material to the walls of the root canal system, promoting a three-dimensional sealing. Even so, with the use of these techniques, there is difficulty in the longitudinal control during the obturation, that could cause the extrusion of the filling material in direction to the perirradicular tissues, influencing the healing after endodontic treatment. Thus, the purpose of this study was to evaluate in vitro the apical extrusion of four thermoplasticized obturation techniques, Thermafil, Obtura II, Ultrafil 3D and Fused, with a new methodology of volume?s measurement of the extruded filling material, relating with the frequency of the visual extrusion of gutta-percha and/or sealer and the final radiographic\'s quality of obturation. The results demonstrated that the methodology of the measurement system was effective to quantify the volume of the extruded filling material, verifying extrusion in all the thermoplasticized techniques studied, even so, quantitatively, the experimental groups didn\'t present statistically significant differences among the averages of volumes. In the radiographic evaluation of the final quality of thermoplasticized obturation, there are evidences that Obtura II technique produced endodontic obturation with qualities statistically inferior of the other techniques. In general, we can consider that Thermafil, Ultrafil 3D and Fused techniques presented similar results in relation to the volume of the extruded filling material and the final radiographic\'s quality of obturation, while Thermafil and Fused techniques exhibited more favorable results in relation to frequency of visual extrusion of gutta-percha and/or sealer.
45

Resistência à infiltração de glicose de quatro cimentos reparadores / Glucose leakage resistance of four repair cements

Fernanda de Souza Leal Fonseca 26 January 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O presente estudo teve como objetivo comparar a qualidade do selamento promovido por 3 cimentos reparadores endodônticos: Ceramicrete, iRoot-BP Plus e BioAggregate, com o ProRoot MTA branco, utilizando o modelo de infiltração de glicose sob pressão. 64 incisivos centrais superiores, recém-extraídos e sem tratamento endodôntico foram selecionados. A instrumentação do canal radicular foi realizada em todos os dentes com brocas Gates-Glidden e limas K-Flexofile (Dentsply Maillefer, Ballaigues Suíça), 1mm aquém do ápice. A patência foraminal foi confirmada a cada instrumento usado. Os dentes tiveram suas coroas removidas padronizando-os em 15mm de comprimento. Foi realizada apicetomia a 3mm do ápice e o preparo da cavidade retrógrada com o auxílio do ultrassom Various 350 (NSKNakanishi Inc., Tóquio, Japão) e da ponta E32D (NSKNakanishi Inc., Tóquio, Japão). As raízes foram distribuídas, randomicamente, em quatro grupos experimentais (n=15): G1Ceramicrete, G2iRoot BP Plus, G3BioAggregate e G4ProRoot MTA branco. Como controle negativo (n=2) foram utilizados dentes hígidos, e como controle positivo (n=2), dentes acessados e com patência confirmada. Os cimentos reparadores foram manipulados seguindo as recomendações do fabricante e inseridos na cavidade retrógrada utilizando a mesma ponta ultrassônica usada no preparo. As amostras foram mantidas na presença de umidade por 72h para o completo endurecimento dos materiais. As raízes foram montadas em um dispositivo de dupla-câmara selada para a infiltração da glicose. Foram utilizados 0,75ml de solução de glicose a 1Mol/L na câmara superior e 0,75ml de água destilada na câmara inferior. Os dispositivos foram conectados a um sistema de distribuição de pressão, que permitiu a infiltração de 32 amostras em uma mesma etapa. A solução de glicose foi forçada apicalmente sob uma pressão de 15psi durante 1 hora. Uma alíquota de 10l foi coletada da câmara inferior para quantificar a glicose infiltrada. A concentração de glicose foi determinada com o auxílio do Kit GlucoseHK (Megazyme, Wicklow, Irlanda) e de um espectrofotômetro de luz visível (Campsec M330, Cambridge, Reino Unido) em um comprimento de onda de 340nm. O teste não-paramétrico Kruskal-Wallis e o teste Dunns foram utilizados na análise estatística. Os resultados encontrados demonstraram que houve diferença significativa entre os grupos experimentais (p=0,0036). O BioAggregate apresentou a maior concentração de glicose-1,85(g/L), seguido do ProRoot MTA-1,2; IRoot BP-0,85 e Ceramicrete-0,75. Não houve diferença entre os três novos cimentos reparadores e o material padrão-ouro (p>0,05). Não houve diferença entre Ceramicrete e iRoot BP Plus (p>0,05), porém estes foram estatisticamente diferentes do BioAggregate (p<0,05). Diante dos resultados obtidos, pode-se concluir que: nenhum dos cimentos testados foi capaz de promover selamento hermético; os três novos cimentos testados não revelaram o mesmo padrão de selamento; os três novos cimentos testados revelaram um padrão de selamento semelhante a do ProRoot MTA branco; e o Ceramicrete e o iRoot BP Plus apresentaram padrão de selamento superior em comparação com o BioAggregate. / The present study sought to compare the sealing ability of three new reparative endodontic cements Ceramicrete, iRoot-BP Plus, BioAggregate and compared to white ProRoot MTA, using the glucose leakage model under pressure. Sixty-four recently extracted maxillary incisors, without previous endodontic treatment, were selected. A crown-down root canal instrumentation was performed using Gates-Glidden burns and Kerr Flexofile (Dentsply Maillefer, Ballaigues Switzerland), 1mm short of the apical foramen (working length). The apical patency was confirmed after the use of each instrument, with a Kerr file #10, 1mm beyond the foramen. The teeth had their crowns removed, leaving roots 15mm in length. After that, apicetomy was carried out at 3mm from the apex. The retrograde preparation was performed using the E32D ultrasonic tip (NSK Nakanishi Inc., Tokyo, Japan). Roots were randomly distributed in four experimental groups (n=15): G1 - Ceramicrete, G2 - iRoot BP Plus, G3 - BioAggregate and G4 - white ProRoot MTA as gold-standard for comparisons. For the negative control group (n=2) teeth with intact crowns were used, and for the positive control (n=2), teeth with access and apical patency. The root-end filling material was manipulated as recommended by the manufacturer and inserted into the retrograde cavity using the same ultrasonic tip. The samples were stored at 100% humidity for three days to allow setting of the material. After that, the roots were mounted in a double-chamber apparatus where 0,75ml of 1Mol/L glucose solution was placed into the superior chamber and 0,75ml of distilled water was placed into the inferior chamber. The devices were connected to a pressure distribution system that was developed to allow the leakage of 32 samples at a single stage. The glucose solution was forced apically under a pressure of 15psi during 1 hour. A sample of 10l was taken from the inferior chamber and the glucose concentration was measured following an enzymatic reaction using the Glucose HK Kit (Megazyme, Wicklow, Ireland) and a spectrophotometer (Campsec M 330, Cambridge, UK) at a wave-length of 340nm. The Kruskal-Wallis and the Dunns test were used for statistical analyses. The results demonstrated that there was significant difference between experimental groups (p=0,0036). BioAggregate displayed the highest glucose concentration - 1.85(g/L), followed by ProRoot MTA - 1.2; iRoot BP Plus - 0.85; Ceramicrete - 0.75. No significant difference was observed between the three new reparative cements and the gold-standard (p>0.05). There was no difference between Ceramicrete and iRoot BP Plus (p>0.05), however both materials were significantly different fromBioAggregate (p<0.05). Considering the results, it can be concluded that none of the tested cements was able to prevent glucose leakage, the 3 new tested cements do not presented a similar quality of sealing, and the three new tested cements presented a similar sealing pattern of ProRoot MTA and both Ceramicrete and iRoot BP Plus presented better quality of sealing than BioAggregate.
46

Produção de CXCL8 e óxido nítrico por neutrófilos humanos estimulados com 4 cimentos endodônticos / Production of CXCL8 and nitric oxide by human neutrophils stimulated with 4 root canal sealers

Milena da Silva 30 October 2013 (has links)
Um material obturador deve apresentar boas propriedades biológicas e físico-químicas, uma vez que ficará em íntimo contato com os tecidos periapicais. Sendo assim, não deve ser irritante aos tecidos adjacentes, possibilitando, ou mesmo favorecendo, o reparo da região periapical, para isso não devem alterar o processo inflamatório. O presente estudo avaliou a citotoxicidade dos cimentos AH Plus, Sealapex, MTA Fillapex e Sealepox em neutrófilos humanos. Neutrófilos humanos cultivados na presença ou ausência de LPS foram tratados com os cimentos em diferentes diluições (1:1, 1:4, 1:8, 1:16 e 1:32) e tempo de presa (24 e 48 horas) durante 24 horas. A viabilidade celular foi analisada por citometria de fluxo, a dosagem de CXCL8 pelo método de ELISA, e Óxido Nítrico na absorvância de 540nm. Os dados foram analisados com o auxílio do programa GraphPad Prism5 por ANOVA a 1 critério seguido pelo teste de Tukey, e os valores considerados significantes quando p<0,05. O cimento AH Plus interferiu apenas na síntese de NO, estimulando-a, tendo a diluição 1:16 melhor comportamento biológico, em ambos períodos experimentais. O Sealapex diminuiu a produção de NO, sendo significante para 1:32 em 48 horas. O MTA Fillapex induziu apoptose, a produção de CXCL8 (1:4 e 1:8 em 48 horas) e diminuiu a síntese de NO (1:32 em 48 horas). Sealepox diminuiu a apoptose (1:16 e 1:32 em 24 horas) e interferiu na produção de CXCL8, diminuindo-a (1:8 em 48 horas, e 1:16 em ambos os períodos). A citotoxicidade em ordem crescente dos cimentos foram: AH Plus, Sealapex, MTA Fillapex e Sealepox. Nosso estudo concluiu que os cimentos AH Plus e Sealapex foram os menos citotóxicos, que menos interferiram na viabilidade celular e na sua função (não indução de CXCL8 e na produção de NO), tanto em 24 horas como em 48 horas. MTA Fillapex e o Sealepox, apesar de causarem mais morte celular e interferirem na produção de NO e CXCL8, seus efeitos podem ser aceitáveis, uma vez que os níveis dessas alterações são, de tal maneira discretos, não agressivos. / A filling material must have good biological and physicochemical, since you\'ll be in close contact with the periapical tissues. Thus it should not be irritating to the surrounding tissues, allowing, or even encouraging, the repair of the periapical region, for it must not alter the inflammatory process. The present study evaluated the cytotoxicity of AH Plus, Sealapex, MTA and Fillapex Sealepox in human neutrophils. Human neutrophils cultured in the presence or absence of LPS cements were treated with different dilutions (1:1, 1:4, 1:8 , 1:16, 1:32) and setting time (24 and 48 hours) for 24 hours. Cell viability was analyzed by flow cytometry, the dosage of CXCL8 by ELISA and nitric oxide in absorbance at 540 nm. Data were analyzed with the aid of GraphPad Prism5 ANOVA for the first criterion followed by Tukey test, and values considered significant when p < 0.05. The AH Plus sealer interfered only in NO synthesis , stimulating it , having a 1:16 dilution better biological behavior , in both experimental periods . The Sealapex decreased production of NO, with 1:32 significant to within 48 hours. The MTA Fillapex induced apoptosis, production of CXCL8 (1:4 to 1:8 within 48 hours) and reduced NO synthesis (1:32 in 48 hours). Sealepox decreased apoptosis (1:16 and 1:32 in 24 hours) and interfere with the production of CXCL8, reducing it (1:8 in 48 hours, and 1:16 in both periods). The cytotoxicity of the cements in ascending order were: AH Plus, Sealapex, MTA and Fillapex Sealepox. We conclude that AH Plus and Sealapex cements were less cytotoxic than less interfered with cell viability and function ( CXCL8 and noninduced NO production ) both in 24 hours and in 48 hours. MTA and Fillapex Sealepox, although most causing cell death and interferes the production of NO and CXCL8, their effects may be acceptable, since the levels of these changes are so mild, non-aggressive.
47

Determinação do pH e da liberação de íons cálcio de três cimentos endodônticos quando utilizados em obturações, em conjunto com guta-percha, e da qualidade das mesmas. Avaliação realizada em longo prazo / Determination of pH, calcium ion release, and overall quality of three endodontic cements used in obturations with guta-percha. A long term evaluation

Paloma Gagliardi Minotti 11 May 2015 (has links)
O objetivo deste estudo foi avaliar o pH e a liberação de íons cálcio dos cimentos AH Plus, MTA Fillapex e Sealapex, em diferentes períodos, quando empregados em obturações de canais radiculares, bem como, a qualidade das obturações, após 1 ano de realizadas. O pH e a liberação de íons cálcio foram avaliados por meio de um peagômetro e espectrofotômetro de absorção atômica, respectivamente. A qualidade das obturações foi avaliada por meio de um estereomicroscópio. Cento e vinte e quatro pré-molares inferiores humanos extraídos, unirradiculados, foram divididos em 01 grupo controle e 02 grupos experimentais, de acordo com a padronização do diâmetro do forame apical. Em seguida, os 02 grupos experimentais foram divididos em 4 subgrupos, considerando as técnicas de instrumentação e obturação empregadas. Após o preparo dos canais radiculares cada subgrupo teve o número de dentes divididos por dois, formando novos subgrupos, de acordo com os cimentos obturadores utilizados. Imediatamente após a obturação, a raiz de cada dente foi imersa em 15 mL de água ultrapura para avaliação do pH e liberação de íons cálcio nos seguintes períodos: 1 h, 1, 3, 7, 30, 180 e 365 dias, após a obturação. Após o período de 1 ano, os dentes foram seccionados transversalmente a 2, 4, 6 mm do forame apical para análise da qualidade das obturações, analisando-se a porcentagem de cimento, guta-percha e espaços vazios na massa obturadora. Os cimentos apresentaram pH neutro, porém, aos 180 dias, os valores mostraram um ligeiro aumento quando utilizados em canais com forames de diâmetro 0,25 mm. Quando utilizados em canais com forames de diâmetro 0,45 mm, o pH mostrou-se com valores maiores para todos os períodos sem distinção do cimento. Todos os cimentos liberaram íons cálcio, com menores valores para o AH Plus. Na estereomicroscopia, observaram-se variações nas porcentagens de cimento e guta-percha, considerando-se os diâmetros foraminais e técnicas obturadoras, e porcentagem insignificante de espaços vazios. / The objective of this study was to evaluate the pH and calcium ion release of AH Plus, MTA Fillapex and Sealapex cements at different time periods when used in root canal obturations, as well as the quality of the obturations one year after being performed. The pH and calcium ion release were evaluated by means of a pH meter and an atomic absorption spectrophotometer, respectively. The quality of the obturations was evaluated using a stereomicroscope. One hundred and twenty-four extracted human uniradicular mandibular premolars were divided into 1 control and 2 experimental groups, according to the standardization of the apical foramen diameter. Next, the 2 experimental groups were divided into 4 subgroups, considering the instrumentation techniques and obturations employed. After the preparation of the root canals, each subgroup had the number of teeth divided by two, forming new subgroups, according to the sealers used. Immediately after the obturation, the root of each tooth was immersed in 15 mL of ultrapure water for the evaluation of the pH and calcium ion release in the following time periods: 1 hr, 1, 3, 7, 30, 180 and 365 days after the obturation. After the period of one year, the teeth were transversely sectioned at 2, 4 and 6 mm from the root apex to examine the quality of the obturations, analyzing the percentage of cement, gutta-percha and voids in the obturator mass. The cements presented a neutral pH, which showed slightly increase as of 180 days when used in canals with foramens of 0.25 mm diameters. When used in canals with foramens with diameters of 0.45 mm, the pH presented higher values in all periods for all cements. All cements released calcium ions, with lower values for the AH Plus. In the stereomicroscopy, there were variations in the percentages of cement and gutta-percha, considering the foraminal diameters and obturation techniques and an insignificant percentage of voids.
48

Avaliação do preparo biomecânico e da obturação de canais radiculares ovais promovidos pelos sistemas de instrumento único WaveOne, Reciproc e SAF / Evaluation of biomechanical preparation and obturation of oval canals using WaveOne, Reciproc and SAF single-file systems

Marco Aurelio Versiani 22 March 2012 (has links)
O objetivo deste estudo ex vivo foi avaliar o preparo biomecânico e a obturação de canais radiculares ovais utilizando os sistemas ProTaper, WaveOne, Reciproc e Self-Adjusting File. Com esta finalidade avaliou-se: 1) área, perímetro, circularidade, diâmetro maior, diâmetro menor, área de superfície, volume e SMI após o preparo biomecânico, por meio de microtomografia computadorizada (&mu;TC); 2) percentual volumétrico de espaços vazios após a obturação do canal, por meio de &mu;TC; 3) resistência de união (RU) e tipo de falha ocorrida após teste de push-out; e 4) a interface dentina/material obturador em microscopia eletrônica de varredura (MEV). Cem caninos inferiores humanos foram escaneados no microtomógrafo SkyScan 1174v.2. Após o preparo do terço cervical dos canais, os dentes foram distribuídos em 4 grupos (n=25), de acordo com o sistema usado no preparo biomecânico: ProTaper; WaveOne; Reciproc; Self-Adjusting File (SAF). Após a segunda &mu;TC, 18 espécimes de cada grupo foram redistribuídos em dois grupos (n=9), de acordo com a técnica de obturação: Técnica Modificada da Onda Contínua de Condensação e técnica recomendada pelo fabricante. Os sete espécimes restantes de cada grupo constituíram os grupos controle negativo e positivo. Após a TC dos espécimes obturados, as raízes foram seccionadas transversalmente em fatias de 1 mm de espessura correspondentes às regiões cervical, média e apical. A RU foi avaliada pelo teste de push-out e as falhas após desunião observadas em microscópio digital. Após preparo para MEV, avaliou-se a interface adesiva de forma qualitativa nominal e ordinal pelo estabelecimento e determinação de escores. No conjunto, a análise dos parâmetros avaliados no preparo biomecânico mostraram que as alterações mais significativas ocorreram nos grupos ProTaper e WaveOne. Os resultados no grupo Reciproc ficaram em um nível intermediário, enquanto as menores alterações foram observadas no grupo SAF (ANOVA, p<0,05). Em relação à obturação, a Técnica Modificada da Onda Contínua de Condensação apresentou menor percentual volumétrico de espaços vazios que a técnica recomendada pelo fabricante apenas no terço cervical (Kruskall-Wallis, p<0,05). Após o teste de push-out, a análise das médias indicou RU (MPa) significativamente maior nos espécimes obturados pela técnica do fabricante em comparação com a Técnica Modificada de Onda Contínua de Condensação (teste t para amostras independentes, p<0,05). Em todos os grupos foi verificado maior percentual de falhas adesivas, com predominância de falhas mistas na técnica do fabricante e de falhas adesiva na dentina na Técnica Modificada de Onda Contínua de Condensação. Em MEV, não houve tags na maioria dos espécimes obturados pela Técnica Modificada da Onda Contínua de Condensação e quando presentes, eram pequenos e irregularmente distribuídos. Nos espécimes obturados pela técnica recomendada pelo fabricante observou-se formação de tags longos e bem distribuídos, principalmente no terço apical (teste de Friedman, p<0,05). Concluiu-se que todos os sistemas resultaram em alterações nos parâmetros bidimensionais e tridimensionais do canal após o preparo biomecânico; a técnica recomendada pelo fabricante resultou em maior volume de espaços vazios no terço cervical e maior RU do material obturador do que a Técnica Modificada de Onda Contínua de Condensação. Obs: tese completa no site: https://rapidshare.com/files/963588082/Tese_Prof._Dr._Marco_Versiani_FORP_USP_2012.pdf (na pagina que abrir, clicar no botao \"download\"). / The purpose of this ex vivo study was to evaluate the biomechanical preparation and obturation of root canals using ProTaper, WaveOne, Reciproc and Self-Adjusting File systems. It was evaluated: 1) area, perimeter, roundness, major diameter, minor diameter, surface area, volume and SMI after biomechanical preparation, using microcomputed tomography (&mu;TC), 2) percentage volume of voids in the obturation material by means of &mu;TC, 3) bond strength (BS) and type of failure after the pushout test, and 4) the analysis of the interface dentin / filling material using scanning electron microscopy (SEM). One-hundred human mandibular canines were scanned in the SkyScan 1174v.2 device. After preparing the coronal third of the canals, the teeth were divided into 4 groups (n=25), according to the biomechanical preparation system used: ProTaper, WaveOne, Reciproc, and Self-Adjusting File (SAF). After the second TC, eigthteen specimens of each group were assigned to two groups (n=9), according to the obturation technique: the Modified Continuous Wave of Condensation Technique and the technique recommended by the manufacturer. The remaining seven specimens of each group were used as negative and positive controls. After scanning, the obturated specimens were sectioned perpendicularly to its long axis into 1-mm slice thickness of the coronal, middle and apical thirds. The bond strength (BS) was performed by the push-out test and, after dislodgments, the failures were observed in a digital microscope. The specimens were processed for SEM analysis to observe bonding interface formation and resin tag density using a four-step scale method. Overall, the analysis of the biomechanical parameters showed that the most significant changes in the root canal occurred in the ProTaper group and WaveOne groups. Reciproc results were in an intermediate level and smaller changes were observed in the SAF group (ANOVA, p<0.05). In the coronal third, the Modified Continuous Wave of Condensation Technique showed a lower percentage volume of voids than the technique recommended by the manufacturer (Kruskal-Wallis test, p<0.05). After the push-out test, the analysis indicated the mean BS (MPa) was significantly higher in specimens filled by the manufacturer\'s technical than the Modified Continuous Wave of Condensation Technique (t test for independent samples, p<0.05). The adhesive failures were frequent in all groups. The Modified Continuous Wave of Condensation Technique showed the highest percentage of adhesive failure in dentin while in the technique recommended by the manufacturer, mixed failure was predominant. Overall, in SEM analysis, no tags were observed in most of the specimens filled by the Modified Continuous Wave of Condensation Technique. When present, they were small and irregularly distributed. The specimens filled by the technique recommended by the manufacturer showed long and well-distributed tags, especially in the apical third (Friedman test, p<0.05). It was concluded that all systems promoted root canal changes after the biomechanical preparation, the obturation technique recommended by the manufacturer resulted in a higher volume of voids in the coronal third and BS of the Modified Continuous Wave of Condensation Technique group.
49

Comparison of the sealing ability of two different types of root canal obturation cold lateral compaction and the continuous wave compaction technique /

Hughart, Donald Wayne. January 2004 (has links)
Thesis (M.S.)--West Virginia University, 2004. / Title from document title page. Document formatted into pages; contains xi, 56 p. : ill. Vita. Includes abstract. Includes bibliographical references (p. 41-44).
50

Infiltração microbiana por Enterococcus faecalis em canais retrobturados com MTA, iRoot SP e Endo CPM Sealer / Microbial leakage by Enterococcus faecalis in root retrofilling with MTA, iRoot SP and Endo COM Sealer

Viviane Dias Martini Alves Nascimento 16 December 2011 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / O objetivo deste trabalho consistiu na análise da infiltração apical em dentes retrobturados por três materiais: MTA, iROOT SP e Endo CPM Sealer. Para tal, foram utilizados 51 dentes humanos extraídos, incisivos centrais superiores, que foram instrumentados manualmente com limas tipo K, pela técnica Crown-down, obturados com compactação lateral e, após serem apicectomizados a 3mm aquém do ápice foram submetidos à retrobturação, com os três materiais propostos. As amostras foram divididas, randomicamente, em três grupos: GI MTA, GII iROOT SP e GIII Endo CPM Sealer, cada grupo com 15 amostras. Os dentes foram inseridos em tubos de eppendorfs, e feitos a impermeabilização do remanescente radicular utilizando duas camadas de cianocrilato, epóxi, e outra camada de esmalte. Em cada eppendorf foi adicionado caldo TSB estéril e uma suspensão de Enterococcos faecalis e adaptado ao frasco de vidro com meio de cultura enterococcosel. A infiltração bacteriana foi verificada pela turvação do meio de cultura. Após a análise no período de 60 dias, podemos concluir que durante esse tempo ocorreram infiltrações no Grupo I, 43,75 % das amostras apresentaram turvamento do meio de cultura demonstrando persistência da infecção. Já no Grupo II, 31,25 % das amostras tiveram crescimento bacteriano. Por fim no Grupo III, 25,00 % houve a infiltração. Grupos controle positivo e negativo para crescimento bacteriano foram realizados (n=3, cada). Os cimentos testados comportaram-se de maneira semelhante frente à infiltração bacteriana durante o período testado. / The objective of this study consisted in the analysis of apical leakage in retrofilled teeth by three materials: MTA, iROOT SP and Endo CPM Sealer. 51 extracted human central incisors were instrumented manually with K-type files by Crown-down technique, filled by lateral compactation and apicectomyzed to 3mm below the apex. Then, teeth were retrofilling with the three proposed materials. The samples were divided, randomly, in three groups: GI - MTA, GII - iROOT SP and GIII - Endo CPM Sealer, each group with 15 samples. Teeth were inserted into eppendorf tubes, and the remaining root were sealed using two layers of cyanoacrylate, epoxy, and another layer of nail varnish. In each eppendorf tube were added sterile TSB broth and a suspension of Enterococcos faecalis. The body proof was adapted to a glass bottle with culture medium Enterococcosel. The bacterial leakage was checked by turbidity of the culture medium. After analysis within 60 days the bacterial leakage was recorded: the Group I showed infiltration in 43.75% of body proof, the Group II in 31.25% and Group III 25%. Positive and negative control groups for bacterial growth were performed (n = 3, each). We can conclude that the tested cements behave similarly to bacterial infiltration front during the period tested.

Page generated in 0.2877 seconds