• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 178
  • 5
  • Tagged with
  • 183
  • 175
  • 67
  • 42
  • 39
  • 25
  • 24
  • 23
  • 23
  • 23
  • 22
  • 19
  • 19
  • 17
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Avaliação do reparo ósseo em cavidades cirurgicamente criadas em fêmur de rato preenchidas com dois biovidros com diferentes taxas de pentóxido de nóbio / Evaluation of bone cavities surgically created in rat femur filled by two bioglasses with different rates of niobium pentoxide

Junges, Alessandra Cláudia January 2015 (has links)
Substitutos ósseos são estudados com a finalidade de encontrar biomateriais que apresentem características semelhantes ao enxerto ósseo autógeno e que tenham facilidade para o seu uso. Em busca desses biomateriais, os vidros bioativos têm sido pesquisados demonstrando propriedades de osteoindução e osteocondução. Este estudo avalia o reparo ósseo associado ao emprego de vidros bioativos diferentes taxas de pentóxido de nióbio 3mol% e 10mol%, comparados ao enxerto ósseo autógeno. A amostra foi composta por 52 ratos aleatoriamente agrupados em quatro tempos experimentais (15, 30, 60, 90 dias pós-operatórios). Três cavidades cirúrgicas foram confeccionadas na diáfise femural direita, preenchidas randomicamente com o enxerto ósseo autógeno e as duas composições de vidros bioativos contendo pentóxido de nióbio. Avaliou-se através de análise histológica, microscopia eletrônica de varredura, microtomografia computadorizada e espectroscopia de micro-Raman. Os resultados mostraram reparo ósseo em estágio avançado pela análise histológica e diferenças significativas (P=0.0017) entre o volume ósseo para o grupo de vidro bioativo composto por 3mol% de nióbio, evidência de incorporação dos biomateriais ao tecido ósseo neoformado pela análise de superfície e alta concentração de fosfato verificada em período precoce nos grupos de vidros bioativos. Tais achados mostraram que os vidros bioativos avaliados apresentaram propriedades de osteocondução e osteoindução. / Bone substitutes are studied in order to find biomaterials that exhibit characteristics similar to autogenous bone graft and have easy to use. In pursuit of these biomaterials, bioactive glasses have been researched demonstrating osteoinductive and osteoconductive properties. This study evaluates bone healing associated with the use of bioactive glasses containing different rates of niobium pentoxide 3mol% and 10mol%, compared to autogenous bone graft. The sample consisted of 52 rats randomly grouped into four times (15, 30, 60, 90 postoperative days). Three surgical cavities were prepared in the right femoral shaft, randomly filled with autogenous bone graft and two compositions of bioactive glasses containing niobium pentoxide. It was evaluated by histological analysis, scanning electron microscopy, computed microtomography and micro-Raman spectroscopy. The results showed bone healing at an advanced stage by histological analysis and significant differences (P = 0.0017) between bone volume to the bioactive glass group of 3mol% niobium, evidence of incorporation of biomaterials to the newly formed bone tissue for surface analysis and High concentration checked phosphate at an earlier period in the groups of bioactive glasses. These findings showed that the evaluated bioactive glasses showed osteoconductive and osteoinductive property.
102

Contribuição da ergonomia para concepção de centrais de esterilização de instrumentos odontológicos

Reis, Luís Francisco Gomes January 2000 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia de Produção / Made available in DSpace on 2012-10-17T22:08:18Z (GMT). No. of bitstreams: 0Bitstream added on 2013-07-16T18:06:54Z : No. of bitstreams: 1 179124.pdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Partimos do contexto que todo instrumental utilizado em procedimentos clínicos e/ou cirúrgicos, nas várias disciplinas do Curso de Odontologia da Universidade Tuiuti do Paraná, devem ser esterilizados na Central de Esterilização de Instrumentos Odontológicos desta Instituição. Desta forma, as atividades exercidas conotam grande responsabilidade, e os funcionários não podem sofrer interferências físicas, ambientais ou organizacionais negativas. Na literatura, pouco se encontra em relação às normas específicas para Centrais de Esterilização em Odontologia, mas sim para Centrais Hospitalares, e portanto os setores responsáveis pela esterilização em Faculdades ou Clínicas, precisam sofrer adaptações. Este fato torna o estudo, um pioneiro na avaliação de condicionantes deste posto de trabalho. O local idealizado para comportar os equipamentos e mobiliário destinado aos processos de esterilização e armazenagem do instrumental dos alunos do Curso de Odontologia da Universidade Tuiuti do Paraná, foi primeiramente vistoriado e aprovado pela Vigilância Sanitária Municipal. A partir de então, foi reformado para receber os equipamentos necessários, mas não foram obedecidas as dimensões antropométricas de seus funcionários. Assim, através da Análise Ergonômica do Trabalho, procurou-se identificar aspectos das condições de trabalho que poderiam estar repercutindo na saúde e no desempenho dos trabalhadores da Central de Esterilização de Instrumentos Odontológicos da Universidade Tuiuti do Paraná, e recomendar mudanças no arranjo do posto de trabalho, adaptando-o às características de seus funcionários. Constatou-se que o ambiente pode estar agindo negativamente nas atividades, assim como as condições físicas do local não são condizentes
103

Desenvolvimento de tecnologia de fabricação de limas Hedstroem

Barba Junior, Durval João de January 1997 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnologico, Programa de Pós-Graduação em Engenharia Mecânica, Florianópolis, 1997 / Made available in DSpace on 2012-10-17T02:13:28Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-08T22:26:57Z : No. of bitstreams: 1 108717.pdf: 52685115 bytes, checksum: 39ff158858b184f2d3982f2ed9555d54 (MD5)
104

Desinfecção de alginato

Meira, Daniela Martins January 2010 (has links)
A presente dissertação, composta de dois manuscritos, buscou preencher lacunas do conhecimento no que diz respeito à desinfecção de impressões de alginato. O primeiro trabalho foi realizado com o intuito de avaliar a eficácia antimicrobiana da solução de glutaraldeído 2% através do seu comportamento bactericida e bacteriostático quando utilizada para desinfecção de impressões de alginato dos pacientes de uma clínica de ensino odontológico de uma instituição federal, durante 28 dias. Logo após a ativação de 3L da solução desinfetante e sempre após a desinfecção de 10 impressões, foram coletadas amostras de 05 mL da solução para a análise microbiológica. No período avaliado, foram imersas 70 impressões de alginato na solução desinfetante. Nenhuma amostra apresentou bactérias viáveis, caracterizando o perfil bacteriostático da solução. Todas as amostras foram capazes de inibir o crescimento de Escherichia coli, Pseudomonas aeruginosa, e Staphylococcus aureus, confirmando o poder bactericida da solução, mostrando que um volume de 3L de glutaraldeído 2% é eficaz como desinfetante de até 70 impressões de alginato ao longo do período de 28 dias. O segundo estudo preocupou-se em avaliar a eficácia do glutaraldeído 2% e do ácido peracético 0,2% em eliminar o microrganismo Staphylococcus aureus, sabidamente presente nos corpos de prova de alginato. Os corpos de prova de alginato foram contaminados com caldo de cultura contendo S. aureus. Estes foram divididos em seis grupos: controle, lavado em água estéril, imersão em glutaraldeído 2% por 5 ou 10 min e imersão em em ácido peracético 0,2% por 5 ou 10 min. Após o tratamento, cada corpo de prova foi incubado em tubo de ensaio com 20 mL de caldo BHI estéril. Posteriormente, amostras do caldo de todos os grupos foram semeadas para determinar a presença de células viáveis. Os resultados mostraram que os grupos controle e o lavado em água estéril apresentaram crescimento bacteriano e que ambos desinfetantes foram eficazes em eliminar S. aureus do alginato tanto após 10 quanto 5 min, de imersão. Os achados desta dissertação permitem concluir que: 3L de solução de glutaraldeído são eficazes para desinfetar até 70 impressões de alginato e que o glutaraldeído 2% e o ácido peracético 0,2% são eficazes na desinfecção de alginato contaminado com S. aureus. / This research made an effort to amplify the knowledge about disinfection of alginate dental impression. The aim of the first study was to evaluate the efficacy of 2% glutaraldehyde solution after successive immersions of contaminated alginate impressions of dental patients from a Dental School by analyzing its bacteriostatic and bactericidal activity through 28 days. After the disinfection of every 10 alginate impressions a 10mL sample of the disinfectant solution (05mL) was collected to be microbiological analyzed. In this period, 70 alginate impressions were immersed in the solution. No viable bacterial grouth was observed at any of the microbiology analyses. All the samples tested were able to inhibit the bacterial growth of Escherichia coli, Pseudomonas aeruginosa and Staphylococcus aureus. The bacteriostatic and bactericidal activity of 2% glutaraldehyde solution was confirmed and 3L of the solution can be safetely used for the disinfection of at least 70 impression during 28 days. The aim of the second study was to evaluate the efficacy of 2% glutaraldehyde and 0.2% peracetic acid against Staphylococcus aureus. Alginate specimens were contaminated at S. aureus culture media. Specimens were divided into six groups: control, washed in sterile water, immersed in 2% glutaraldehyde for 5 or 10 minutes and immersed in 0,12% peracetic acid for 5 or 10 minutes. The results showed that control and sterile water showed bacterial growth and that both disinfectants (glutaraldehyde and peracetic acid) showed efficacy against S. aureus for both immersion period of time (5 and 10 minutes). The findings of these studies allowed the conclusion that 3L of glutaraldehyde solution showed efficacy to disinfect up to 70 alginate impressions and that, both 2% glutaraldehyde and 0.2% peracetic acid are efficient to disinfect S. aureus contamined alginate impressions.
105

Influência do tratamento com EDTA no embricamento de dois cimentos resinosos à parede do canal radicular

Salles, Alexandre Azevedo January 2001 (has links)
Resumo não disponível.
106

Desenvolvimento e caracterização de um cimento endodôntico experimental a base de resina epóxica com adição de sais de bismuto

Schwartzer, Eduardo January 2011 (has links)
O objetivo deste trabalho foi desenvolver e caracterizar um cimento endodôntico experimental a base de resina epóxica com a adição de diferentes proporções de três sais de bismuto, seguindo os requisitos das normas ISO 6876 e ISO 4049 em busca da composição que atendesse estas normas. Para isto, foram formulados dezoito grupos com resina epóxica e adição de 20%; 40%; 60%; 80%; 100% e 120% em massa de três diferentes sais de bismuto. Foram realizados ensaios de escoamento, tempo de trabalho, tempo de presa, espessura de película, alteração dimensional, sorção e solubilidade, radiopacidade e citotoxicidade. Os resultados foram comparados com requisitos das normas ISO 6876 e 4049 e submetidos a ANOVA de duas vias (tipo de carga e concentração) e teste de Tukey com nível de significância de 5%. Os cimentos com subnitrato e subcarbonato de bismuto demonstram-se promissores, com especial destaque às formulações contendo subnitrato de bismuto por apresentarem resultados superiores. A adição de carga a partir de 80% conferiu radiopacidade satisfatória para os cimentos com subnitrato e subcarbonato de bismuto. Para os cimentos com subsalicilato de bismuto a única concentração que atendeu à norma foi de 120%. No ensaio de citotoxicidade nenhuma das formulações apresentou diferença estatística significativa quando comparado ao controle. Conclui-se que o subnitrato de bismuto e subcarbonato de bismuto apresentam características para utilização como carga e radiopacificante em cimentos endodônticos a base de resina epóxica. / The aim of this study was the development and evaluating of an experimental endodontic sealer epoxy based after addition of three different bismuth salts, according to the requirements of ISO 6876 and 4049 searching for the composition with better performance. Eighteen groups were formulated with the inclusion of 20%, 40%, 60%, 80%, 100% and 120% of three different bismuth salts, by weight, on epoxy resin. Then, flow tests, working time, setting time, film thickness, dimensional change, sorption and solubility, radiopacity and cytotoxicity were performed. Data were analyzed by two-way ANOVA (type of filler and concentration) and Tukey at a level of significance of 5%. The formulations with bismuth subsalicylate did not show suitable properties. However, cements with bismuth subnitrate and subcarbonate shown to be promising, particularly with regard to formulations containing bismuth subnitrate, wich presented superior results. The addition of 80% salt generated satisfactory radiopacity to subcarbonate and bismuth subnitrate sealers, bismuth subsalicylate had only reached satisfatory radiopacity at 120%. In the cytotoxicity assay none of the formulations showed statistical significance when compared to control. It is concluded that the formulations containing bismuth subnitrate and bismuth subcarbonate have potential use as filler in endodontic sealers.
107

Avaliação do desgaste dentinário promovido pelas técnicas de instrumentação manual e rotatória em dentes decíduos de humanos

Kummer, Thais Regina January 2006 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-22T12:26:08Z (GMT). No. of bitstreams: 1 226907.pdf: 1717513 bytes, checksum: 5a2ef9a376a5bb40b30da567ccaedc27 (MD5) / O objetivo desta pesquisa foi avaliar in vitro o tempo de instrumentação e o desgaste dentinário promovido pela instrumentação manual e rotatória em dentes decíduos de humanos. A amostra foi constituída por 80 dentes divididos em dois grupos (n=40) e subdivididos de acordo com os grupos dentais. Para instrumentação manual, foi utilizada a técnica convencional com limas tipo K. Para a instrumentação rotatória, foi utilizado o preparo coroa-ápice com o sistema Hero 642. Todos os canais foram preparados até o instrumento de n° 40 e o tempo foi registrado por um cronômetro. Os dados foram analisados estatisticamente usando o teste de Mann-Whitney e Teste t. A instrumentação manual apresentou maior desgaste no terço coronário e médio de todas as raízes e grupos dentais quando comparada à instrumentação rotatória (p<0,05), exceto no terço coronário dos dentes anteriores. O tempo médio da instrumentação rotatória foi menor para todos os grupos dentais (p<0,05). Os dentes decíduos possuem estrutura radicular suficiente para serem instrumentados até o n°.40, pelas técnicas manual e rotatória. A técnica rotatória promoveu menor desgaste e preparos mais uniformes, bem como, resultou no menor tempo de instrumentação dos canais.
108

Desenvolvimento e caracterização de adesivo ortodôntico contendo triazina e vidro bioativo nióbio-fosfato

Altmann, Aline Segatto Pires January 2015 (has links)
Pacientes ortodônticos apresentam grande prevalência de lesões de mancha branca devido ao maior acúmulo de biofilme em torno dos brackets. O objetivo deste estudo foi desenvolver um adesivo ortodôntico que apresentasse atividade antibacteriana e que estimulasse a deposição mineral para evitar o aparecimento e/ou a evolução destas lesões. Adesivos experimentais foram formulados contendo 75% de BisGMA e 25% de TEGDMA por peso; sistema fotoiniciador a base de canforoquinona e 5% de sílica coloidal. Os compostos 1,3,5-triacriloilhexahidro-1,3,5-triazina (TAT) e vidro fosfato invertido contendo pentóxido de nióbio (PIG-Nb) foram adicionados ao adesivo base, como agente antibacteriano e remineralizante, respectivamente. Foram analisados grupos contendo somente TAT nas concentrações de 10, 15 e 20% por peso; grupos contendo somente PIG-Nb nas concentrações de 1, 2,5 e 5% por peso e um grupo contendo 20% TAT e 5% PIG-Nb, por peso. Utilizou-se um grupo sem a adição de TAT e PIG-Nb como Grupo Controle, dentre os experimentais. O adesivo ortodôntico comercial Transbond XT foi utilizado para comparação. Avaliou-se a atividade antibacteriana, capacidade de deposição mineral, variação de pH, grau de conversão, amolecimento em solvente e resistência de união dos adesivos ortodônticos. Os adesivos desenvolvidos apresentaram atividade antibacteriana e capacidade de estimular deposição mineral sem prejudicar as propriedades dos adesivos. Os resultados obtidos a partir dos ensaios realizados neste trabalho permitem concluir que se trata de material com propriedades favoráveis e potencialidade de, após ajustes necessários, tornar-se viável para uso na prática odontológica. / White spot lesions are a concern for orthodontic patients due to biofilm accumulation around brackets. The aim of this study was to develop an antibacterial and remineralizing orthodontic adhesive to overcome these lesions. Experimental orthodontic adhesives were formulated containing 75wt% BisGMA and 25wt% TEGDMA; camphorquinone-based photoinitiator system and 5wt%fummed silica. The compounds 1,3,5-tryacryloylhexahydro-1,3,5-triazine (TAT) and phosphate invert glass containing niobium pentoxide (PIG-Nb) were added to the adhesive as antibacterial and remineralizing agents, respectively. Experimental groups obtained containing only TAT at 10, 15 and 20wt% concentration; groups containing only PIG-Nb at 1, 2.5 and 5wt%, and one group containing 20wt% TAT and 5wt% PIG-Nb. A groups without TAT and PIG-Nb was used as Control and Transbond XT was used as a commercial control. Antibacterial activity, mineral deposition, changes in pH, degree of conversion, softening in solvent and shear bond strength of orthodontic adhesives was assessed. The experimental adhesives presented antibacterial activity and were capable to induce mineral deposition with no negative effect on adhesive's properties. The results of this study allow the conclusion that this material has favorable properties and potential, after necessary adjustments become viable for use in dental practice.
109

Avaliação do reparo ósseo de defeitos criados em maxila e preenchidos com hidroxiapatita com taxa Ca/P modificada : estudo experimental em ratos

Daudt, Eduardo Boero January 2015 (has links)
Estudos prévios sugerem que a modificação da superfície de uma hidroxiapatita sinterizada, através do condicionamento ácido, favorece a interação deste biomaterial com o organismo. Este estudo avaliou o reparo de defeitos ósseos preenchidos por hidroxiapatita sinterizada modificada (HAM), taxa Ca/P = 1.5 e hidroxiapatita sinterizada pura (HA), taxa Ca/P = 1.67, em um modelo experimental in vivo. Foram utilizados 52 ratos, submetidos à confecção de defeitos ósseos que promoveram as exposições das raízes mesiais dos primeiros molares superiores, sendo utilizado implante de HAM no lado direito e, como controle, HA no lado esquerdo. Os animais foram distribuídos randomicamente em quatro tempos pós-operatórios (15, 30, 60 e 90 dias). Após a morte dos animais, as peças foram preparadas e avaliadas através de análise histológica, microscopia eletrônica de varredura (MEV) e microtomografia computadorizada (MicroCT). Os resultados mostraram maior neoformação óssea associada à HAM (p=0.009). Na análise longitudinal a HAM apresentou neoformação óssea superior no tempo experimental de 90 dias pós-operatório comparado aos tempos de 15 e 30 dias pós-operatórios (p=0.014 e p=0.018 respectivamente). Para os parâmetros atividade osteoclástica e processo inflamatório não foram observadas diferenças estatisticamente significativas entre HAM e HA (p=0.446 e p=0.411, respectivamente). As avaliações através da MicroCT demonstraram aumento da densidade óssea ao longo dos tempos experimentais para a HAM (p=0.0042), mas não para HA (p=0.356). A microscopia eletrônica de varredura permitiu a observação das microporosidades associadas à HAM e a incorporação dos biomateriais ao tecido ósseo. Nas condições experimentais desse estudo, a aplicação de HAM resulta em melhor reparo ósseo, quando comparada a HA. / Previous studies suggest that modifying the surface of a sintered hydroxyapatite (HA) through acid-etching favors the interaction between the biomaterial and organism. This study evaluated bone repair of defects filled with a modified sintered hydroxyapatite (HAM; Ca/P ratio = 1.5), and sintered hydroxyapatite (HA; Ca/P ratio = 1.67), in an experimental model in vivo. Bone defects were created to promote mesial roots exposure of superior first molars in 52 rats. HAM implant was put into the right side bone defect and HA was used on the left side, as control. Animals were randomized into four postoperative groups (15, 30, 60 and 90 days) and killed, respectively, in each time. Surgical pieces were prepared and essessed by histological analysis, scanning electron microscopy (SEM) and computed microtomography (MicroCT). The results showed increased bone formation associated with HAM (p = 0.009). Higher bone formation was related to HAM at 90 days postoperative compared to 15 and 30 days after surgery (p = 0.014 and p = 0.018, respectively). No statistically significant differences were found between HAM and HA for osteoclastic activity and inflammation (p = 0.446 and p = 0.411, respectively). MicroCT showed increased bone density throughout the experimental periods for the HAM (p = 0.0042), but not for HA (p = 0 356). Scanning electron microscopy allowed the observation of microporosities associated with HAM and the incorporation of biomaterials in bone tissue. Under the experimental conditions of this study, the application of HAM results in better bone healing compared to HA.
110

Avaliação do reparo ósseo em cavidades cirurgicamente criadas em fêmur de rato preenchidas com dois biovidros com diferentes taxas de pentóxido de nóbio / Evaluation of bone cavities surgically created in rat femur filled by two bioglasses with different rates of niobium pentoxide

Junges, Alessandra Cláudia January 2015 (has links)
Substitutos ósseos são estudados com a finalidade de encontrar biomateriais que apresentem características semelhantes ao enxerto ósseo autógeno e que tenham facilidade para o seu uso. Em busca desses biomateriais, os vidros bioativos têm sido pesquisados demonstrando propriedades de osteoindução e osteocondução. Este estudo avalia o reparo ósseo associado ao emprego de vidros bioativos diferentes taxas de pentóxido de nióbio 3mol% e 10mol%, comparados ao enxerto ósseo autógeno. A amostra foi composta por 52 ratos aleatoriamente agrupados em quatro tempos experimentais (15, 30, 60, 90 dias pós-operatórios). Três cavidades cirúrgicas foram confeccionadas na diáfise femural direita, preenchidas randomicamente com o enxerto ósseo autógeno e as duas composições de vidros bioativos contendo pentóxido de nióbio. Avaliou-se através de análise histológica, microscopia eletrônica de varredura, microtomografia computadorizada e espectroscopia de micro-Raman. Os resultados mostraram reparo ósseo em estágio avançado pela análise histológica e diferenças significativas (P=0.0017) entre o volume ósseo para o grupo de vidro bioativo composto por 3mol% de nióbio, evidência de incorporação dos biomateriais ao tecido ósseo neoformado pela análise de superfície e alta concentração de fosfato verificada em período precoce nos grupos de vidros bioativos. Tais achados mostraram que os vidros bioativos avaliados apresentaram propriedades de osteocondução e osteoindução. / Bone substitutes are studied in order to find biomaterials that exhibit characteristics similar to autogenous bone graft and have easy to use. In pursuit of these biomaterials, bioactive glasses have been researched demonstrating osteoinductive and osteoconductive properties. This study evaluates bone healing associated with the use of bioactive glasses containing different rates of niobium pentoxide 3mol% and 10mol%, compared to autogenous bone graft. The sample consisted of 52 rats randomly grouped into four times (15, 30, 60, 90 postoperative days). Three surgical cavities were prepared in the right femoral shaft, randomly filled with autogenous bone graft and two compositions of bioactive glasses containing niobium pentoxide. It was evaluated by histological analysis, scanning electron microscopy, computed microtomography and micro-Raman spectroscopy. The results showed bone healing at an advanced stage by histological analysis and significant differences (P = 0.0017) between bone volume to the bioactive glass group of 3mol% niobium, evidence of incorporation of biomaterials to the newly formed bone tissue for surface analysis and High concentration checked phosphate at an earlier period in the groups of bioactive glasses. These findings showed that the evaluated bioactive glasses showed osteoconductive and osteoinductive property.

Page generated in 0.1331 seconds