• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Novel Birefringent Frequency Discriminator for Microwave Photonic Links

Kim, Jae Hyun 03 October 2013 (has links)
A novel photonic frequency discriminator has been developed. The discriminator utilizes a Mach Zehnder interferometer-assisted ring resonator to achieve enhanced linearity. A numerical frequency-domain two-tone test is performed to evaluate the unique design of the discriminator, particularly for suppression of the third order intermodulation distortion. The discriminator is switchable between linear-intensity and linear-field regimes by adjusting a phase delay on one arm of the Mach Zehnder interferometer. Through the simulation, the linear<intensity discriminator is shown to be advantageous. The discriminator is an optical ring resonator-Mach Zehnder interferometer synthesized passive filter. The ring resonator is made of Arsenic trisulfide (As2S3) and the bus waveguide is a Titanium<diffused Lithium niobate (LiNbO3) waveguide. This As2S3 ring-on-Ti:LiNbO3 hybrid structure offers electro-optic tunability of the device owing to a strong electro-optic effect of the substrate material. A large optical confinement factor achieved by vertical integration of the As2S3 strip waveguide on a LiNbO3 substrate enables a low loss ring resonator. The Mach Zehnder interferometer is formed by the optical path length difference of the birefringent LiNbO3 substrate instead of a physical Y-branch structure, which makes the fabrication tolerances relaxed. In order for this highly birefringent device to be characterized, each polarization mode must be measured separately. A novel algorithm which can measure the wavelength-swept Jones matrix including its phase response is devised. The efficacy of the algorithm is demonstrated by characterizing a ring resonator. Finally, the fabricated discriminator is fully characterized using the algorithm.
2

Rolled-up microtubes as components for Lab-on-a-Chip devices

Harazim, Stefan M. 29 November 2012 (has links) (PDF)
Rolled-up nanotechnology based on strain-engineering is a powerful tool to manufacture three-dimensional hollow structures made of virtually any kind of material on a large variety of substrates. The aim of this thesis is to address the key features of different on- and off-chip applications of rolled-up microtubes through modification of their basic framework. The modification of the framework pertains to the tubular structure, in particular the diameter of the microtube, and the material which it is made of, hence achieving different functionalities of the final rolled-up structure. The tuning of the microtube diameter which is adjusted to the individual size of an object allows on-chip studies of single cells in artificial narrow cavities, for example. Another modification of the framework is the addition of a catalytic layer which turns the microtube into a self-propelled catalytic micro-engine. Furthermore, the tuneability of the diameter can have applications ranging from nanotools for drilling into cells, to cargo transporters in microfluidic channels. Especially rolled-up microtubes based on low-cost and easy to deposit materials, such as silicon oxides, can enable the exploration of novel systems for several scientific topics. The main objective of this thesis is to combine microfluidic features of rolled-up structures with optical sensor capabilities of silicon oxide microtubes acting as optical ring resonators, and to integrate these into a Lab-on-a-Chip system. Therefore, a new concept of microfluidic integration is developed in order to establish an inexpensive, reliable and reproducible fabrication process which also sustains the optical capabilities of the microtubes. These integrated microtubes act as optofluidic refractrometric sensors which detect changes in the refractive index of analytes using photoluminescence spectroscopy. The thesis concludes with a demonstration of a functional portable sensor device with several integrated optofluidic sensors. / Die auf verspannten Dünnschichten basierende „rolled-up nanotechnologie“ ist eine leistungsfähige Methode um dreidimensionale hohle Strukturen (Mikroröhrchen) aus nahezu jeder Art von Material auf einer großen Vielfalt von Substraten herzustellen. Ausgehend von der Möglichkeit der Skalierung des Röhrchendurchmessers und der Modifikation der Funktionalität des Röhrchens durch Einsatz verschiedener Materialien und Oberflächenfunktionalisierungen kann eine große Anzahl an verschiedenen Anwendungen ermöglicht werden. Eine Anwendung behandelt unter anderem on-chip Studien einzelner Zellen wobei die Mikroröhrchen, an die Größe der Zelle angepasste, Reaktionscontainer darstellen. Eine weitere Modifikation der Funktionalität der Mikroröhrchen kann durch das Aufbringen einer katalytischen Schicht realisiert werden, wodurch das Mikroröhrchen zu einem selbstangetriebenen katalytischen Mikro-Motor wird. Hauptziel dieser Arbeit ist es Mikrometer große optisch aktive Glasröhrchen herzustellen, diese mikrofluidisch zu kontaktieren und als Sensoren in Lab-on-a-Chip Systeme zu integrieren. Die integrierten Glasröhrchen arbeiten als optofluidische Ringresonatoren, welche die Veränderungen des Brechungsindex von Fluiden im inneren des Röhrchens durch Änderungen im Evaneszenzfeld detektieren können. Die Funktionsfähigkeit eines Demonstrators wird mit verschiedenen Flüssigkeiten gezeigt, dabei kommt ein Fotolumineszenz Spektrometer zum Anregen des Evaneszenzfeldes und Auslesen des Signals zum Einsatz. Die entwickelte Integrationsmethode ist eine Basis für ein kostengünstiges, zuverlässiges und reproduzierbares Herstellungsverfahren von optofluidischen Mikrochips basierend auf optisch aktiven Mikroröhrchen.
3

Self-assembled rolled-up devices: towards on-chip sensor technologies

Smith, Elliot John 13 September 2011 (has links) (PDF)
By implementing the rolled-up microfabrication method based on strain engineering, several systems are investigated within the contents of this thesis. The structural morphing of planar geometries into three-dimensional structures opens up many doors for the creation of unique material configurations and devices. An exploration into several novel microsystems, encompassing various scientific subjects, is made and methods for on-chip integration of these devices are presented. The roll-up of a metal and oxide allows for a cylindrical hollow-core structure with a cladding layer composed of a multilayer stack, plasmonic metamaterial. This structure can be used as a platform for a number of optical metamaterial devices. By guiding light radially through this structure, a theoretical investigation into the system makeup of a rolled-up hyperlens, is given. Using the same design, but rather propagating light parallel to the cylinder, a novel device known as a metamaterial optical fiber is defined. This fiber allows light to be guided classically and plasmonically within a single device. These fibers are developed experimentally and are integrated into preexisting on-chip structures and characterized. A system known as lab-in-a-tube is introduced. The idea of lab-in-a-tube combines various rolled-up components into a single all-encompassing biosensor that can be used to detect and monitor single bio-organisms. The first device specifically tailored to this system is developed, flexible split-wall microtube resonator sensors. A method for the capturing of embryonic mouse cells into on-chip optical resonators is introduced. The sensor can optically detect, via photoluminescence, living cells confined within the resonator through the compression and expansion of a nanogap built within its walls. The rolled-up fabrication method is not limited to the well-investigated systems based on the roll-up from semiconductor material or from a photoresist layer. A new approach, relying on the delamination of polymers, is presented. This offers never-before-realized microscale structures and configurations. This includes novel magnetic configurations and flexible fluidic sensors which can be designed for on-chip and roving detector applications.
4

Rolled-up microtubes as components for Lab-on-a-Chip devices

Harazim, Stefan M. 09 November 2012 (has links)
Rolled-up nanotechnology based on strain-engineering is a powerful tool to manufacture three-dimensional hollow structures made of virtually any kind of material on a large variety of substrates. The aim of this thesis is to address the key features of different on- and off-chip applications of rolled-up microtubes through modification of their basic framework. The modification of the framework pertains to the tubular structure, in particular the diameter of the microtube, and the material which it is made of, hence achieving different functionalities of the final rolled-up structure. The tuning of the microtube diameter which is adjusted to the individual size of an object allows on-chip studies of single cells in artificial narrow cavities, for example. Another modification of the framework is the addition of a catalytic layer which turns the microtube into a self-propelled catalytic micro-engine. Furthermore, the tuneability of the diameter can have applications ranging from nanotools for drilling into cells, to cargo transporters in microfluidic channels. Especially rolled-up microtubes based on low-cost and easy to deposit materials, such as silicon oxides, can enable the exploration of novel systems for several scientific topics. The main objective of this thesis is to combine microfluidic features of rolled-up structures with optical sensor capabilities of silicon oxide microtubes acting as optical ring resonators, and to integrate these into a Lab-on-a-Chip system. Therefore, a new concept of microfluidic integration is developed in order to establish an inexpensive, reliable and reproducible fabrication process which also sustains the optical capabilities of the microtubes. These integrated microtubes act as optofluidic refractrometric sensors which detect changes in the refractive index of analytes using photoluminescence spectroscopy. The thesis concludes with a demonstration of a functional portable sensor device with several integrated optofluidic sensors. / Die auf verspannten Dünnschichten basierende „rolled-up nanotechnologie“ ist eine leistungsfähige Methode um dreidimensionale hohle Strukturen (Mikroröhrchen) aus nahezu jeder Art von Material auf einer großen Vielfalt von Substraten herzustellen. Ausgehend von der Möglichkeit der Skalierung des Röhrchendurchmessers und der Modifikation der Funktionalität des Röhrchens durch Einsatz verschiedener Materialien und Oberflächenfunktionalisierungen kann eine große Anzahl an verschiedenen Anwendungen ermöglicht werden. Eine Anwendung behandelt unter anderem on-chip Studien einzelner Zellen wobei die Mikroröhrchen, an die Größe der Zelle angepasste, Reaktionscontainer darstellen. Eine weitere Modifikation der Funktionalität der Mikroröhrchen kann durch das Aufbringen einer katalytischen Schicht realisiert werden, wodurch das Mikroröhrchen zu einem selbstangetriebenen katalytischen Mikro-Motor wird. Hauptziel dieser Arbeit ist es Mikrometer große optisch aktive Glasröhrchen herzustellen, diese mikrofluidisch zu kontaktieren und als Sensoren in Lab-on-a-Chip Systeme zu integrieren. Die integrierten Glasröhrchen arbeiten als optofluidische Ringresonatoren, welche die Veränderungen des Brechungsindex von Fluiden im inneren des Röhrchens durch Änderungen im Evaneszenzfeld detektieren können. Die Funktionsfähigkeit eines Demonstrators wird mit verschiedenen Flüssigkeiten gezeigt, dabei kommt ein Fotolumineszenz Spektrometer zum Anregen des Evaneszenzfeldes und Auslesen des Signals zum Einsatz. Die entwickelte Integrationsmethode ist eine Basis für ein kostengünstiges, zuverlässiges und reproduzierbares Herstellungsverfahren von optofluidischen Mikrochips basierend auf optisch aktiven Mikroröhrchen.
5

Self-assembled rolled-up devices: towards on-chip sensor technologies

Smith, Elliot John 29 August 2011 (has links)
By implementing the rolled-up microfabrication method based on strain engineering, several systems are investigated within the contents of this thesis. The structural morphing of planar geometries into three-dimensional structures opens up many doors for the creation of unique material configurations and devices. An exploration into several novel microsystems, encompassing various scientific subjects, is made and methods for on-chip integration of these devices are presented. The roll-up of a metal and oxide allows for a cylindrical hollow-core structure with a cladding layer composed of a multilayer stack, plasmonic metamaterial. This structure can be used as a platform for a number of optical metamaterial devices. By guiding light radially through this structure, a theoretical investigation into the system makeup of a rolled-up hyperlens, is given. Using the same design, but rather propagating light parallel to the cylinder, a novel device known as a metamaterial optical fiber is defined. This fiber allows light to be guided classically and plasmonically within a single device. These fibers are developed experimentally and are integrated into preexisting on-chip structures and characterized. A system known as lab-in-a-tube is introduced. The idea of lab-in-a-tube combines various rolled-up components into a single all-encompassing biosensor that can be used to detect and monitor single bio-organisms. The first device specifically tailored to this system is developed, flexible split-wall microtube resonator sensors. A method for the capturing of embryonic mouse cells into on-chip optical resonators is introduced. The sensor can optically detect, via photoluminescence, living cells confined within the resonator through the compression and expansion of a nanogap built within its walls. The rolled-up fabrication method is not limited to the well-investigated systems based on the roll-up from semiconductor material or from a photoresist layer. A new approach, relying on the delamination of polymers, is presented. This offers never-before-realized microscale structures and configurations. This includes novel magnetic configurations and flexible fluidic sensors which can be designed for on-chip and roving detector applications.

Page generated in 0.094 seconds