Spelling suggestions: "subject:"ortodônticos""
71 |
Efeitos do etanol e nicotina sobre a resistencia mecanica do osso e osteogenese ao redor de implantes de hidroxiapatita / Effects of ethanol and nicotine on the mechanical resistance of the bone and osteogenesis around hydroxypatite osteogenesisSoares, Evelise Aline, 1978- 25 June 2007 (has links)
Orientador: Jose Angelo Camilli / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Biologia / Made available in DSpace on 2018-08-09T00:19:55Z (GMT). No. of bitstreams: 1
Soares_EveliseAline_M.pdf: 1118469 bytes, checksum: 6b9e5d9f187903596cc09bef1862eaa1 (MD5)
Previous issue date: 2007 / Resumo: O consumo de álcool ou nicotina é prejudicial à integridade do tecido ósseo, conseqüentemente, pode dificultar ou até mesmo impedir a fixação e manutenção dos implantes osseointegráveis. O objetivo do presente trabalho foi avaliar os efeitos do etanol e nicotina sobre a resistência mecânica do osso e a neoformação óssea ao redor de implantes de hidroxiapatita, quando consumidos isoladamente e simultaneamente. Foram utilizados 20 ratos divididos em quatro grupos de 05, sendo controle (CT), álcool (A), nicotina (N) e nicotina+álcool (N+A). Após quatro semanas de consumo de álcool e/ou nicotina, corpos cerâmicos densos (HAD) e porosos (HAP) de hidroxiapatita foram implantados em cavidades produzidas cirurgicamente nas tíbias. Após as cirurgias os animais continuaram a consumir álcool e/ou nicotina. Completado noventa dias, os animais foram sacrificados e as tíbias e fêmures isolados para o processamento histológico e ensaio mecânico. Em todos os animais foi encontrado tecido ósseo junto aos corpos cerâmicos de HAD e HAP. O volume de osso formado ao redor dos corpos cerâmicos foi maior no grupo CT em relação aos demais grupos. Os animais do grupo N+A foram aqueles que apresentaram menor volume de osso neoformado. Nos animais do grupo A ocorreu formação de menor volume de osso ao redor dos implantes em relação aos animais do grupo Nicotina. A menor resistência do osso a cargas mecânicas foi encontrada nos animais do grupo N, A e N+A, respectivamente. De acordo com os resultados podemos concluir que o consumo de nicotina ou álcool produziu efeito negativo sobre a resistência mecânica do osso e osteogênese ao redor dos implantes de HAD e HAP. Em adição, o consumo simultâneo das duas substâncias intensificou os efeitos deletérios / Abstract: The consumption of alcohol or nicotine is harmful to the integrity and mechanical resistance of the bone. Consequently, it can difficult or even prevent the osseintegration and maintenance of bone implants. The objective of the present work was to evaluate the effects of the ethanol and nicotine on the mechanical resistance of the bone and newly formed bone around hydroxyapatite implants, when consumed separated and simultaneously. A total of 20 adults rats were divided into 4 groups of 5 rats each, being control (CT), alcohol (A), nicotine (N) and nicotine+alcohol (N+A). After four weeks of consumption of alcohol and nicotine, dense (HAD) and porous (HAP) ceramic bodies of hydroxyapatite were implanted in cavities produced surgically in the tibiae. After the implantation the animals continued to consume alcohol and nicotine. Completed ninety days, the animals were sacrificed and the tibiae and femurs were isolated to histological and mechanical studies. In all animals was founded newly formed bone around the ceramic bodies of HAD and HAP. The bone volume formed around of the ceramic bodies was larger in the group CT than that founded in the other groups. The animals of the group N+A presented smaller volume of newly formed bone. In the animals of the group A was founded smaller volume o bone than in the animals of the group N. The resistance of the femur to mechanical loads was smaller in the animals that consumed N+A, A e N respectively. In agreement with the results we can conclude that the nicotine or alcohol consumption produced negative effect on the mechanical resistance of the bone and osteogenesis around the HAD and HAP implants. In addition, the simultaneous consumption of the two substances intensified the harmful effects / Mestrado / Anatomia / Mestre em Biologia Celular e Estrutural
|
72 |
Avaliação do desempenho de implantes de polietileno e de fosfato tricalcio, recobertos por hidrogel, em defeitos osteocondrais no joelho de cães / Performance evaluation in implants of polyethylene and tricalcium phosphate, covered by hydrogels, in osteochondral defects in dogs'kneesGarrido, Luiz Fernando 27 February 2007 (has links)
Orientador: William Dias Belangero / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-09T02:25:23Z (GMT). No. of bitstreams: 1
Garrido_LuizFernando_M.pdf: 3331524 bytes, checksum: 50f44c5fff048c0f9e4c220b4f7e52f4 (MD5)
Previous issue date: 2007 / Resumo: Este estudo teve como objetivo avaliar o desempenho in vivo, de implantes cilíndricos com altura e diâmetro de 5mm formados por cerâmica ß-tricálcio fosfato (ß-TCP) ou polietileno de ultra-alto peso molecular (PEUAPM) todos recobertos com hidrogel de poli (2-hidroxi etil metacrilato) - poli(metacrilato de metila-co-ácido acrílico) (75:25) (pHEMA/poli (MMA-co-AA)) para preencher defeitos osteocondrais nos joelhos direito e esquerdo de cães. Foram operados treze cães machos com peso entre 15 e 25 kg fornecidos pelo Canil do Centro Multi Institucional de Bioterismo da Unicamp, sem raça definida, em bom estado de nutrição, vacinados após período prévio de quarentena. Cinco cães foram utilizados como controle e oito foram seguidos por nove meses após a colocação dos implantes. Os implantes de cerâmica foram colocados no sulco troclear do joelho direito e os de polietileno no joelho esquerdo. Foram realizadas análises da superfície do implante macroscópica (in vivo e in vitro), mecânica e microscópica, com a finalidade de avaliar a formação de tecido sobre o implante, o seu desgaste, o se desempenho viscoelástico e a interface formada entre o implante e o tecido ósseo. Os implantes de cerâmica apresentaram desempenho inferior ao polimérico, em todos os critérios avaliados. Embora não tenha havido desgaste significativo na superfície do hidrogel os dois implantes estudados produziram abrasão na superfície da patela / Abstract: This study had the purpose of evaluating ¿in vivo¿ the performance of ß-TCP ceramic or extreme high molecular weight polyethylene cylindrical implants, with height and diameter of 5mm, all covered with poly(2-HEMA) ¿ poly(methyl methacrilate-co-acrilic acid) hydro gel (polyHEMA/poly(MMA-co-AA) (75:25) in order to fill in bone defects in both the right and left knees of dogs. Thirteen male dogs weighting between 15 and 25kg, supplied by UNICAMP¿s Centro Multi Institucional de Bioterismo, were operated. All the dogs were well nourished, vaccinated and the operation took place after a previous quarantine period. Five dogs were used as control and eight were followed for nine months after putting the implants. The ceramic implants were placed in the right knees and the polyethylene ones in the left knees. Macroscopic, mechanic and microscopic analyses of the implant surface, (both in vivo and in vitro) were performed, in order to evaluate the tissue formation on the implant, the wearing off of the implant, the viscoelastic performance and the interface between the implant and the bone tissue. The ceramic implants presented an inferior performance when compared to the polymeric ones, in all of the evaluated aspects. Although there was no significant degradation on the hydro gel surface, both studied implants produced erosion on the kneecap surface / Mestrado / Cirurgia / Mestre em Cirurgia
|
73 |
Avaliação da biocompatibilidade de diamantes microestruturados e nanoestruturados : ensaios " in vitro" e "in vivo" / Evaluation the biocompatibility of microcrystalline and nanocrystallime diamond: "in vitro" and "in vivo" assaysRodrigues, Ana Amélia 30 August 2006 (has links)
Orientador: Vitor Baranauskas / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-08-09T14:59:50Z (GMT). No. of bitstreams: 1
Rodrigues_AnaAmelia_M.pdf: 19209454 bytes, checksum: 1a2efefc090d27e2715b48aad097989d (MD5)
Previous issue date: 2006 / Resumo: O desenvolvimento de novos materiais para a produção de implantes ortopédicos tem sido uma busca constante, devido principalmente ao aumento das aplicações clínicas e à necessidade de se alcançar maior durabilidade, diminuindo assim as cirurgias de revisão. O diamante CVD obtido por deposição química da fase vapor é um novo material com grande potencial de uso devido às suas excelentes propriedades físico-químicas. Dentre elas pode-se destacar a inércia química, extrema dureza e baixo coeficiente de atrito, características importantes para materiais que necessitam resistir ao desgaste e à corrosão
produzida pelos fluídos do corpo humano. O objetivo deste estudo foi avaliar pela análise ¿in vitro¿ e ¿in vivo¿ a biocompatibilidade de tubos de diamante microcristalino e diamante nanocristalino produzidos pela deposição química de vapor em filamento quente
(CVD). Palavras Chave: diamante CVD, biomateriais, implantes, próteses / Abstract: The development of new materials for orthopedic implants has been a quest due to the increasing number of clinical applications and necessity of achieving larger durability for lessening the need for revision surgeries. Diamond CVD (Chemical Vapour Deposition) is a new material with larger potential of future use due its excellent physico-chemical properties like for instance, high chemical inertness, extreme hardness and low friction coefficient. The aim of this study is to evaluate by ¿in vitro¿ and ¿in vivo¿ assays the biocompatibility of microcrystalline and nanocrystalline diamond self-sustaining tubes produced by hot-filament chemical vapor deposition (CVD).
Key Words: chemical-vapor-deposited diamond, biomaterials, implants, prosthesis / Mestrado / Engenharia de Computação / Mestre em Engenharia Elétrica
|
74 |
Tecnica de nanorisco para analise de adesão de revestimento de HA, depositada atraves de aspersão por plasma, sobre liga de titanio / Nanoscratch test applied to adhesion analysis of HA coated by plasma spray process over titanium alloyFernandes, Beatriz Luci 29 July 1999 (has links)
Orientador: Cecilia A. C. Zavaglia / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-25T02:10:22Z (GMT). No. of bitstreams: 1
Fernandes_BeatrizLuci_D.pdf: 8612737 bytes, checksum: 5b82e95884b98b376d5146b5ea2586e9 (MD5)
Previous issue date: 1999 / Resumo: Apesar dos 30 anos de história, engenheiros e pesquisadores continuam procurando soluções para problemas que persistem até os dias de hoje, em relação à resistência ao desgaste de superfícies articuladas e à fixação aos tecidos ósseos de implantes ortopédicos de quadril. Esses problemas estão interligados, desde que a formação de grandes partículas nas articulações é o principal fator responsável pela perda da prótese e a qualidade da fixação do implante determina a produção dessas partículas. O material das amostras, analisadas neste trabalho, foi um dos empregados atualmente em próteses totais de quadril não cimentadas, ou seja, liga Ti6Al-7Nb revestida de hidroxiapatita (HA), aplicada através da técnica de aspersão por plasma. O principal objetivo deste trabalho foi apresentar uma alternativa para a avaliação da resistência da interface, utilizando-se uma nova técnica, rápida e confiável. As informações contidas estão relacionadas à técnica de deposição de materiais em forma de pó através de aspersão por plasma; ao estudo da resistência à adesão da HA sobre a liga de titânio através de ensaio de nanorisco e à caracterização superficial das amostras por determinação da rugosidade superficial, difração de raio-X e imagens do Microscópio Eletrônico de Varredura / Abstract: In spite of 30 years of history, engineers and researchers in general, are still trying to find solutions for the problems related to wear resistance of sliding surfaces and related to biological attachment of hip prostheses. These two questions are connected since the debris released in the joints are the main factor for loosing the prostheses and the fixation quality determines the production of those debris. The samples analyzed on this work were made of materials presently applied on hip prostheses like Ti-6Al-7Nb alloy with hydroxyapatite coating applied by plasma spray method. The main purpose of this work was to present an alternative to analyze the adhesion strength between the HA and the Ti-6Al-7Nb alloy using a new technique, fast and reliable. The information presented are related to the plasma spray' s deposition technique using powdered materials, to the evaluation of the interface between the two materials through the nanoscratch test and to the surface characterization using a mechanical profiler (profilometer), an X-Ray Diffract meter and a Scanning Electron Microscope / Doutorado / Materiais e Processos de Fabricação / Doutor em Engenharia Mecânica
|
75 |
Componentes com gradientes funcionais para aplicação em ortopedia obtidos por manufatura aditiva de ligas de titânio / Functional graded components for application in orthopedics obtained by additive manufacturing of titanium alloysLima, Dalton Daniel de, 1986- 31 July 2015 (has links)
Orientador: Rubens Caram Júnior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-28T12:00:08Z (GMT). No. of bitstreams: 1
Lima_DaltonDanielde_M.pdf: 2611996 bytes, checksum: 6f81a7094a8af1637dc4d3bda71dacd3 (MD5)
Previous issue date: 2015 / Resumo: O uso de ligas do sistema Ti-Nb-Zr como biomaterial é promissor em razão de sua boa biocompatibilidade, alta resistência à corrosão, elevada resistência mecânica e baixo módulo de elasticidade. As propriedades mecânicas de ligas Ti-Nb-Zr podem ser manipuladas variando-se o teor de Nb e Zr no componente, o que é obtido aplicando-se o processo de manufatura aditiva LENS®. Tal processo é uma técnica inovadora e permite produzir componentes tridimensionais com gradientes de composição e consequentemente, com gradientes funcionais. Materiais com gradiente funcionais são exigidos, em alguns casos, no reparo de tecidos duros do corpo humano. Por exemplo, em placas de fixação de fratura óssea é interessante alto módulo de elasticidade em regiões próximas à fratura e baixo módulo de elasticidade em regiões adjacentes à fratura. O objetivo desse trabalho foi estudar, do ponto de vista metalúrgico, a possibilidade de se produzir materiais para aplicação ortopédica fabricados com ligas Ti-Nb-Zr com gradientes de composição aplicando-se o processo LENS®. Para isso foram produzidos lingotes medindo 12 x 12 x 55 mm, com extremidades com composições nominais de Ti-35Nb-10Zr (% em peso) (região de baixo módulo), a região central de Ti CP (região de alto módulo) e as regiões entre o centro e as extremidades, com composições intermediárias. Cada lingote foi cortado simetricamente no sentido longitudinal, resultando em duas amostras (placas). Uma amostra foi caracterizada no estado como solidificada e a outra, após tratamento térmico de solubilização a 1000 °C por 1 h e resfriada em água. A caracterização das amostras envolveu fluorescência de raios-X e análise de teor de O e N para determinação da composição. Microscopia eletrônica de varredura, difração de elétrons retroespalhados e difração de raios-X foram utilizadas para análise microestrutural. Nanoindentação, medida de microdureza Vickers e análise de módulo de elasticidade por ultrassom para análise do comportamento mecânico. Verificou-se que é possível obter materiais com gradientes funcionais pelo processo LENS® dentro do sistema Ti-Nb-Zr. As amostras apresentaram módulo de elasticidade variando entre 65 a 110 GPa ao longo de seu comprimento / Abstract: The use of Ti-Nb-Zr alloys system as biomaterial is promising due to its good biocompatibility, high corrosion resistance, high strength and low modulus of elasticity. The mechanical properties of Ti-Nb-Zr alloys can be manipulated varying the content of Nb and Zr in the component production. This variation is obtained by applying the additive manufacturing process LENS®. This process is a novel technique and allows the production of three-dimensional components with compositional gradients and hence with functional gradients. Functionally graded materials are required in some cases, for repair of hard tissues of human body. In bone fracture fixation plates, for example, is interesting that the closest fracture regions possess high Young's modulus while adjacent fracture regions low Young's modulus. The aim of this work was to study, of metallurgical point of view, the possibility of producing materials, for orthopedic application, manufactured with Ti-Nb-Zr alloys with composition gradients applying the LENS®. To this, ingots measuring 12 x 12 x 55 mm were produced. Its ends were produced with the nominal composition Ti-35Nb-10Zr (wt%) (low modulus region), the central region was produced with CP Ti (high modulus region) and the regions between the extremities and central, with intermediate composition. Each ingot was symmetrical cut in longitudinal way, resulting in two samples (plates). One sample was characterized as the solidified state and the other one, after solubilization heat treatment at 1000 °C for 1 h and cooled in water. The samples were characterized by X-rays fluorescence and analysis of O and N content for compositions determining. Scanning electron microscopy, electron backscattering diffraction and X-ray diffraction were used for microstructural analysis. Nanoindentation technique, Vickers microhardness measure and measurement of Young's modulus by ultrasound were used for mechanical properties analysis. It has been found that it is possible to obtain functional gradients materials by the LENS® process within Ti-Nb-Zr system. The samples had modulus ranging from 65 to 110 GPa along its length / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica
|
76 |
Design colaborativo e o processo de desenvolvimento de dispositivos para reabilitação do membro superior / Collaborative design and the device development process for upper limb rehabilitationCasagranda, Kelin Luana January 2018 (has links)
As órteses de membro superior são dispositivos que auxiliam na reabilitação da mão e que tem como objetivo estabilizar, imobilizar, prevenir e corrigir deformidades, melhorando assim a função. O processo tradicional de confecção de órteses é realizado por meio do uso de termoplásticos de baixa temperatura, material moldado diretamente sobre o membro do usuário, sendo neste processo relatados inúmeros problemas, que envolvem desconforto durante o processo, alto custo e baixa adesão do paciente ao uso. O presente trabalho, portanto, teve por objetivo propor a construção de um framework com abordagem metodológica projetual para a produção de órteses de membro superior baseada no processo de design e design colaborativo, com auxílio de recursos de fabricação digital, como digitalização tridimensional e manufatura aditiva (impressão 3D). Através de uma pesquisa exploratória, foram discutidas questões relativas ao projeto de órteses de membro superior (MMSS) pela forma tradicional, utilizando termoplástico de baixa temperatura, e questões do processo de design no desenvolvimento de novos produtos a serem aplicadas do desenvolvimento de órteses utilizando a manufatura aditiva A coleta de dados contou com a participação dos principais personagens envolvidos no processo, usuários de órteses, Terapeutas Ocupacionais e Designers. Com base na técnica de card sorting e entrevistas, foi elaborado um framework da abordagem projetual para a criação de órteses utilizando processos de fabricação digital, de forma colaborativa. O framework ainda foi aplicado no desenvolvimento de uma órtese a fim de avaliar os resultados e melhorias levantadas durante a fase de entrevistas com profissionais e usuários. Ao final do processo, obteve-se uma órtese funcional em que foram atendidos os requisitos necessários para a produção de uma órtese levantada pelo trabalho, além da criação do framework servindo como um guia para o desenvolvimento de órteses utilizando a manufatura aditiva. / Upper limb orthoses are devices that assist in the rehabilitation of the hand and that aim to stabilize, immobilize, prevent and correct deformities, thus improving the function. The traditional process of making orthotics is accomplished through the use of thermoplastics of low temperature, molded material directly on the member of the user, being in this process reported numerous problems, that involve discomfort during the process, high cost and low adhesion of the patient to the use. The present work, therefore, aimed to propose the construction of a framework with a design methodological approach for the production of upper limb orthosis based on the process of design and collaborative design, with the aid of digital manufacturing resources such as three - dimensional digitization and additive manufacturing (3D printing). Through an exploratory research, questions regarding the design of upper limb orthoses (MMSS) in the traditional way, using low-temperature thermoplastic, and design process issues in the development of new products to be applied in the development of orthoses using the additive manufacture The data collection was attended by the main characters involved in the process, users of orthoses, Occupational Therapists, and Designers. Based on the technique of card sorting and interviews, a framework of the design approach for the creation of orthoses using digital manufacturing processes was developed in a collaborative way. The framework was also applied in the development of a bracing in order to collaborate with the results and improvements raised during the interviews phase with professionals and users. At the end of the process, a functional orthosis was obtained, in which the necessary requirements for the production of an orthosis were obtained by the work, besides the creation of a framework serving as a guide for the development of orthoses using the additive manufacture.
|
77 |
Resistencia mecánica del fijador externo descartable y del fijador externo reusable. Hospital Nacional Dos de MayoQuispe Juárez, José Groverli January 2014 (has links)
Determina la resistencia mecánica del fijador externo descartable (FED) y del fijador externo reusable (FER) a la compresión axial y flexión. Se determinó la resistencia a la compresión axial y a la fuerza de flexión del fijador externo descartable en configuración transfixiante y en configuración no transfixiante, y del fijador externo reusable en configuración no transfixiante. Se realizó la prueba en una máquina de ensayos universal en el laboratorio de estructuras antisísmicas de la PUCP, a una velocidad de 2,5 mm/ min hasta lograr un desplazamiento a nivel del foco de fractura de 10 mm. Se retiró la fuerza deformante y se evaluó la deformación residual. Finalmente se procedió a una carga de compresión axial en ambos modelos de fijador externo hasta determinar su límite de falla. Para 10 mm de desplazamiento axial fueron necesarios 213.49 kg en el fijador externo descartable transfixiante y de 238.12 kg para el fijador externo descartable no transfixiante. El modelo de fijador externo reusable resistió 94.67 kg. La deformación residual fue de 2.95 mm en promedio para el FED transfixiante, 4 mm para el FED no transfixiante y 7.75 mm para el FER. Bajo cargas deflexivas hasta 10 mm de desplazamiento el FED transfixiante resistió 46.69 kg y el FER 152.40 kg. Se concluye que el FED y FER, en modelos de construcción habitual tienen una resistencia mecánica a las cargas axial y deflexivas similares a otros modelos mundialmente usados, siendo el FED el que mejor resiste la carga axial y el FER la carga en flexión. La estructura que falla en carga máxima en el FED es el cemento y en el FER son los tubos de aluminio. / Trabajo de investigación
|
78 |
Diseño de una ortesis para miembro superior con estimulación eléctrica funcional para mejorar el movimiento en pacientes con lesiones prolongadasChuquimbalqui Sanchez, Victiliano Saul January 2022 (has links)
Los traumatismos y lesiones prolongadas causadas por accidentes o enfermedad neuronal es un problema que va en aumento de salud pública que afecta de forma directa a las personas que lo padecen, e indirectamente a los familiares y al entorno de estas. El paciente sufre mental y físicamente por la discapacidad asociada, es un impacto negativo a su entorno socioeconómico, además si el paciente es de limitados recursos no podrá acceder a órtesis comerciales por su alto costo en el mercado.
La presente tesis se diseña una órtesis de miembro superior donde se implementó la combinación de dos técnicas totalmente diferentes, diseñar una órtesis en el software CAD CAE SolidWorks, esta órtesis que es un dispositivo externo para mantener la postura o estructura del sistema muscular y esquelético, se utilizara un microcontrolador Arduino UNO para captar las ondas musculares también conocida como EMG (electromiografía), con el lenguaje programación C++, realizamos el código en el software libre ARDUINO UNO, esto es uno de los métodos más importantes para mejorar el movimiento de músculos lesionados.
Se recopilo información de personas que han sufrido lesiones prolongadas en el brazo, para saber el grado de la lesión que ha sufrido, se evaluó a los pacientes con el fin de implementar, finalmente se realizó el modelo con la información obtenida de las fases anteriores, se realizó simulaciones en software especializado ya mencionados. Al finalizar la investigación se obtuvo un diseño de órtesis de codo articulado de brazo y antebrazo con EMG (electromiografía) funcional en beneficio de personas que sufren y se encuentran limitados de recursos económicos, incentivando a futuros investigadores a seguir abordando este tema.
|
79 |
Diseño de una ortesis de rodilla con sistema de actuadores para asistir la articulación en pacientes con artrosisChaname Leon, Fabrizio Adrian January 2022 (has links)
En la actualidad las personas con problemas de artrosis no solo afectan a las personas mayores de edad sino también a deportistas jóvenes, los casos más frecuentes son aquellas que afectan a la rodilla lo que les provoca una dificultad caminar debido a que no cuenta con la suficiente fuerza para utilizar su pierna como apoyo.
Existen modelos de soportes de rodillas que ayudan a tener un mayor soporte al usuario al caminar reduciendo el dolor, funcionan a través de presión, pero el modelo de estas tiene movilidad limitada.
En la presente tesis se diseñará una ortesis que les dé a los usuarios una mejor movilidad. Esta contará con una estructura materiales compuestos que sea resistente y ergonómica, Además el actuador brindará todo el soporte necesario para realizar movimientos de rodilla sin un mayor esfuerzo, podrá ser adquirido con facilidad para todos los usuarios con los casos de artrosis en la rodilla.
Se utilizará para el diseño y el análisis dinámico el programa SOLIDWORKS, también se tendrá en cuenta estudios médicos sobre los problemas que causa la artrosis en la zona de la rodilla y sus métodos de
tratamiento.
|
80 |
Avaliação de endoprótese nacional em traquéia de coelhos. / Auto-expansible endoprosthesis. Biocompatibility in rabbits trachea.Faria, Celso Murilo Nálio Matias de 22 November 2011 (has links)
Made available in DSpace on 2016-01-26T12:51:38Z (GMT). No. of bitstreams: 1
celsomurilonmdefaria_dissert.pdf: 1426679 bytes, checksum: 62fc4b90d691c716aef67c9e6590368e (MD5)
Previous issue date: 2011-11-22 / Introduction: the utilization of endoprosthesis has its main indication in the neoplasic obstructions do not surgically treatable. The foreign industry dependence is one of the barriers we found for the broad utilization of such devices. The relevance of this research is the development of a national prosthesis from easy access and low cost. Objective: to assess the biocompatibility of nitinol endoprosthesis with polyurethane in the rabbits trachea. Material and Method: Seventeen rabbits were studied from the New Zealand breed (Oryctolagus Sylvilagus), eight male and five female, with an average weight of 3255g (from 2570 to 4270g). The endoprosthesis were applied orally through laringoscopy, under general anesthesia and released in the middle third of the trachea. Radiological study was made to assure the placement of the endoprosthesis that allowed to compare the index of migration of the endoprosthesis in millimeters. The proposed time segment was 30 days. The microscopic variables study was proceeded: dilatation, incorporation and granolomatous tissue and histological cuts from the tracheal and lungs segments for microscopic study. The histological study measured the inflammatory process, the parietal alterations and the kind of epithelium observed in the tracheal bed. Results: Thirteen animals were included in the final study. The average segment time was 26 days (15 to 35 days in observation). Six animals underwent a radiological study during euthanasia and it was demonstrated displacement with migration of the prosthesis for the distal trachea in five animals. There was absence in one. It was shown the prosthesis had a complete expansion in seven animals and partial expansion in six. The incorporation of prosthesis in the tracheal lumen was observed in two animals and adhered in eleven. Granulomatous tissue was present in ten animals and absent in three. The histological study of the mucosa and submucosa showed inflammatory process predominantly of Polymorphonuclear cells as in the contact region with the prosthesis as in the proximal. The depth of the inflammatory process in the tracheal wall was larger in the tracheal area in contact with the prosthesis. The alterations of the respiratory epithelium: the metaplasia parameter was the most frequent in the area without contact with the prosthesis. Corrosion and ulceration were predominant in the area in contact with the prosthesis. The metaplasia parameter was the most frequent in the area in contact with the prosthesis. Conclusion: the nitinol endoprosthesis auto-expandable covered with polyurethane, produced by Braile Biomédica and implanted in the trachea of rabbits was easy to apply and liberation in the tracheal lumen. The endoprosthesis recovered with polyurethane showed in radiographic assessment distal migration, good radial expandability and formation of granuloma tissue. It was also observed an inflammatory process predominantly acute and restricted to the superficial portions of the trachea. The most frequent epithelium alterations in contact with the prosthesis were ulceration and regenerative hyperplasia. / Introdução: a utilização de endoprótese tem a principal indicação nas obstruções neoplásicas e nas obstruções não tratáveis cirurgicamente. A dependência da indústria estrangeira é uma das barreiras para utilização ampla destes dispositivos. A relevância deste trabalho é o desenvolvimento de uma prótese nacional de fácil acesso e baixo custo. Objetivo: avaliar endoprótese de nitinol revestida com poliuretano, na traqueia de coelhos. Material e Método: foram estudados 17 coelhos, da raça Nova Zelândia (Oryctolagus Cuniculus). Oito machos e nove fêmeas, com peso médio de 3522g (de 2570 a 4270g). As endopróteses foram aplicadas via oral, por meio de laringoscopia, sob anestesia geral, e liberadas no terço médio das traqueias. Realizou-se estudo radiológico para assegurar a posição da endoprótese que permitiu comparar o índice de migração da endoprótese em milímetros. O tempo proposto de seguimento foi de 30 dias. Procedeu-se ao estudo das variáveis macroscópicas: dilatação, incorporação e tecido de granulação e cortes histológicos dos segmentos traqueais e pulmonares para estudo microscópico. O estudo histológico mensurou o processo inflamatório, as alterações parietais e o tipo de epitélio observado no leito traqueal. Resultados: 13 animais foram incluídos no estudo definitivo. O tempo médio de seguimento foi 26 (15 a 35) dias em observação. Em seis animais submetidos a estudo radiológico por ocasião da eutanásia, demonstrou-se deslocamento com migração da prótese para traqueia distal, em cinco; ausência de migração em um. Demonstrou-se que a prótese tinha expansão completa em sete animais e parcial em seis. A incorporação da prótese na luz traqueal foi observada em dois animais, e aderido em 11. Tecido de granulação esteve presente em dez animais e ausente em três. O estudo histológico da mucosa e submucosa demonstrou processo inflamatório com predomínio de polimorfonucleares tanto na região em contato com a prótese quanto na proximal. A profundidade do processo inflamatório na parede traqueal foi maior na área traqueal em contato com a prótese. Das alterações do eptélio respiratório, o parâmetro metaplasia foi o mais frequente na área sem contato com a prótese. Corrosão e ulceração predominaram na área em contato com a prótese. Conclusões: A escolha do coelho no desenho do presente estudo prejudicou o resultado. Trata-se de estudo pioneiro tanto na utilização de coelho para estudo de endoprótese, quanto no desenvolvimento de endoprótese metálica autoexpansível nacional. As dificuldades foram naturais deste pioneirismo, mas prejudicaram o resultado final. A endoprótese autoexpansível de nitinol recoberta de poliuretano, produzida pela Braile Biomédica Ltda, (Brasil) e implantada na traqueia de coelhos, demonstrou-se de fácil aplicação e liberação na luz traqueal. Apresentou elevada taxa de migração, boa expansibilidade radial. Verificou-se alta frequência na formação de tecido de granulação e baixa permeabilidade. Observou-se ainda processo inflamatório predominantemente agudo e restrito ás porções superficiais da traquéia. As alterações epiteliais mais freqüentes em contato com a prótese foram ulceração e hiperplasia regenerativa.
|
Page generated in 0.083 seconds