• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 26
  • 1
  • Tagged with
  • 28
  • 28
  • 11
  • 10
  • 9
  • 7
  • 7
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Desenvolvimento de um sistema embarcado para medição de corrente

Santos, Túlio Luiz dos 16 July 2013 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-graduação em Engenharia Elétrica, Florianópolis, 2010 / Made available in DSpace on 2013-07-16T04:04:21Z (GMT). No. of bitstreams: 1 281833.pdf: 1713087 bytes, checksum: d911ca2f405905bbcc6b400d8996d5ee (MD5) / Esta dissertação aborda o desenvolvimento de um sistema embarcado próprio para ser aplicado na medição de correntes elétricas utilizando bobina de Rogowski como transdutor. Em específico, trata da parte da eletrônica embarcada de um sistema desenvolvido que pode ser aplicado no monitoramento de corrente de fuga de para-raios de alta tensão a fim de auxiliar a avaliação das condições operacionais. Assim, o trabalho se restringe a uma parcela do desenvolvimento do sistema de medição de corrente. Sob o aspecto dos dados mensurados, implementou-se rotinas para a obtenção de valores de corrente de pico, de corrente eficaz (RMS), da taxa total de distorção harmônica (THD), bem como fornece uma análise harmônica da forma de onda mensurada. O sistema embarcado é alimentado por baterias e conta com circuitos para tratamento e condicionamento de sinal, um microcontrolador do tipo ARM (Advanced Risc Machines), mostrador gráfico e sistema de monitoramento remoto através de um módulo de rádio. Apresentam-se algumas formas de onda medida e são realizadas comparações dos valores medidos para validar o sistema desenvolvido.
12

Sistema de aterramento com cabo contrapeso representado por linhas de transmissão implementado em Matlab com circuitos em cascatas de PÍ

Spozito Junior, José Saverio [UNESP] 24 May 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-05-24Bitstream added on 2014-06-13T20:09:46Z : No. of bitstreams: 1 spozitojunior_js_me_ilha.pdf: 739577 bytes, checksum: 774270e35ff8542bb48191719879dc4a (MD5) / Este estudo é um levantamento de artigos e publicações sobre os diversos sistemas de aterramento existentes. Os sistemas de aterramento estão diretamente ligados à proteção das instalações de subestações e equipamentos empregados na geração, transmissão e distribuição de energia elétrica que por ocasião das descargas atmosféricas diretas ou por tensões induzidas por campos eletromagnéticos decorrentes, possam ser prejudicados. O Método propõe o estudo de um sistema de aterramento, com cabo contrapeso, utilizando abordagem por linhas de transmissão representada por uma cascata de circuitos π, analisado e simulado pelo “Software Matlab”. Utilizou-se a simulação com o emprego de programa no Matlab para linhas de transmissão de energia elétrica, a primeira com comprimento de dez mil metros e outra com oitenta metros, utilizada como referencial na comparação das respostas aos sinais de entrada aplicados nos circuitos π simulando o cabo contrapeso com seus componentes representado pelos parâmetros elétricos. Através de variação no parâmetro resistividade do solo comparou-se os resultados mostrados nos gráficos da tensão elétrica na terminação do cabo contrapeso, simulado como uma linha de transmissão com terminação em aberto. Como analise adicional em termos de segurança foi implementado no programa a analise das tensões elétricas ao longo do cabo contrapeso, excitado por aplicação de sinais de tensão elétrica e de corrente elétrica estabelecendo a comparação entre os potenciais elétricos sobre o solo em valores máximos que podem afetar seres vivos / This study is a survey of articles and publications on the various existing grounding systems. The grounding systems are directly linked to the protection of substation facilities and equipment used in the generation, transmission and distribution of electric power, due to induced voltages by lightning’s generating electromagnetic fields . The method proposed in this study, about a grounding system made with a buried cable using the approach by transmission lines method, represented by a cascade of π circuits analyzed and simulated by Matlab Software. The simulation with the Matlab program on transmission lines of electricity, one ten thousand meters in length and another eighty meters respectively, to serve as a reference in comparison between responses to input signals applied to the cable simulated by π circuit employing the parameters involved. Through variation in the soil resistivity parameter, the results are shown in the graphs of voltage in the termination of the grounding cable, simulated as an open line at end. As further analysis in terms of safety, was implemented the analysis of the voltages along the cable, by applying voltage signals and current to check the electrical potentials on the ground, the maximum values that affect persons
13

Análise da penetração de umidade em para-raios poliméricos de distribuição / Analysis of moisture ingress into polymeric surge arresters used in distribution energy systems

Silva, Daiana Antonio da, 1987- 20 August 2018 (has links)
Orientador: José Pissolato Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-20T15:35:10Z (GMT). No. of bitstreams: 1 Silva_DaianaAntonioda_M.pdf: 4722111 bytes, checksum: 375d62ec89d5043ee6edb2f08c980d9d (MD5) Previous issue date: 2012 / Resumo: Sistemas de energia elétrica estão constantemente sujeitos à sobretensões classificadas como internas, decorrentes de operações de manobras e chaveamento no próprio sistema; ou sobretensões decorrentes de agentes externos, por exemplo, descargas atmosféricas. Em ambas as situações, para-raios de óxido de zinco (ZnO) tem sido uma solução eficaz, tanto para os transitórios lentos e oscilatórios quanto para os transitórios rápidos e impulsivos. A utilização de para-raios de óxido de zinco com invólucro polimérico nesses casos é relativamente recente, recorrendo a meados dos anos 80. As informações sobre o desempenho elétrico desses dispositivos ao longo de anos de uso ou quando submetidos a condições críticas de operação são escassas e pouco difundidas na literatura técnica disponível. Dessa forma, uma análise criteriosa é proposta para avaliar o desempenho elétrico de para-raios com invólucro de silicone utilizados nos sistemas de distribuição de energia elétrica, em função da degradação físico-química dos mesmos. São realizados, então, 3 meses de ensaio de imersão/envelhecimento das amostras em água com cloreto de sódio à temperatura de 90 °C, visando representar 20 anos de aplicação do dispositivo em campo. A avaliação do desempenho elétrico é realizada através de medições periódicas da corrente de fuga e da tensão residual, enquanto a avaliação físico-química é obtida através da qualificação do invólucro de silicone utilizado nos para-raios por meio da classificação do grau de hidrofobicidade / Abstract: Electric power systems are constantly subjected to internal overvoltages, i.e. resulting from switching and mechanical operations in the system, or then overvoltages resulting from external causes, e.g. atmospheric surges. In both situations, metal-oxide surge arresters have been an efficacious solution for fast and impulsive electromagnetic transients as well as for slow and oscillatory transients. The use of polymeric metal oxide surge arresters, against atmospheric surges as well as for switching operations, is a relatively recent, dating back to the 1980s. However, the information on the electrical performance of these devices throughout the years of use, or when submitted to critical conditions of operation, is scarce and poorly discussed in the available technical literature. Thus, a thorough analysis is proposed to evaluate the electrical performance of surge arresters with silicone housing, commonly applied in the distribution network, as a function of their physical-chemical degradation. In order to represent 20 years of the field device, 3 months of immersion test/aging in water with sodium chloride at a temperature of 90 degrees will be performed. The evaluation will be through periodic measurements of the leakage current and residual voltage. Another objective is to describe the silicone housing used in surge arresters for classifying the degree of hydrophobicity / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
14

Avaliação do tempo de secagem e da qualidade da imagem de radiografias submetidas a banho em alcool etilico em diferentes concentraçãoes / Evaluation of drying period and quality of image of radiographs submitted to immersion in ethyl alcohol at different concentrations

Damian, Melissa Feres 28 February 2005 (has links)
Orientador: Francisco Haiter Neto / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T04:03:37Z (GMT). No. of bitstreams: 1 Damian_MelissaFeres_D.pdf: 735238 bytes, checksum: 0d3e3519a1b631b044005442d3fbbf3e (MD5) Previous issue date: 2005 / Resumo: Com este estudo, teve-se a proposta de avaliar a ação do álcool etílico, nas concentrações de 46ºGL, 70ºGL e 92ºGL, como agente acelerador da secagem de radiografias dentárias, a fim de abreviar o tempo de processamento. Adicionalmente, foi verificado se esse produto poderia causar alterações na dens idade, nas propriedades sensitométricas e na qualidade destas radiografias após um curto período de arquivamento. Para tanto, foram utilizados os filmes radiográficos intra-orais de sensibilidade D (Dspeed), E (E-speed) e E/F (Insight) da Kodak, divididos em grupos de acordo com o uso e a concentração da substância alcoólica. Todos os filmes foram processados manualmente pelo método temperatura/tempo em câmara escura portátil para simular condições clínicas. As radiografias foram submetidas às analises densitométrica e clínica subjetiva, além da construção de curvas características para a obtenção do contraste e da sensibilidade, nos períodos correspondentes a um e seis meses após a realização do experimento, simulando condições de arquivo. Pôde-se observar que o uso do álcool etílico acelerou a secagem das radiografias independentemente do tipo de filme, sendo que o menor tempo foi obtido com a utilização da substância alcoólica de maior concentração. Contudo, os valores de densidade, contraste e sensibilidade foram alterados quando foi utilizado o álcool 70ºGL e o álcool 92ºGL, sendo que este último também foi capaz de alterar a qualidade visual das imagens. Tais alterações puderam ser visualizadas nos dois períodos de avaliação de estudo. Assim, concluiu -se que mesmo que o álcool etílico acelere a secagem das radiografias, sua utilização causou alterações capazes de prejudicar a qualidade da imagem, inclusive após um curto período de arquivamento / Abstract: This study evaluated the action of ethyl alcohol at concentrations of 46ºGL, 70ºGL and 92ºGL as an accelerator of drying of dental radiographs, with a view to reduce the time required for processing. Also, it was observed whether this product might cause alterations in the density, sensitometric properties and quality of these radiographs after a 6- month storage period. For that purpose, intraoral radiographic films D-speed, E-speed and E/F (Insight) of Kodak were employed, which were divided into groups according to the utilization and concentration of the alcoholic substance. All films were developed manually by the time-temperature method in a portable dark room, to simulate the clinical conditions. The radiographs were submitted to densitometric and clinical analyses, besides construction of characteristic curves for achievement of contrast and sensitivity, at periods corresponding to one and six months after accomplishment of the study, simulating conditions of storage. It was observed that the utilization of ethyl alcohol accelerated the drying of radiographs, regardless of the type of film; the shortest time was achieved with utilization of the alcoholic substance of highest concentration. However, the density, contrast and speed of radiographs were altered when concentrations of 70ºGL and 92ºGL were used; being that the latter also altered the visual quality of images. Such alterations could be observed at the two evaluations and study periods. Thus, it was concluded that, even though the ethyl alcohol may accelerate the drying of radiographs, its utilization caused alterations able to impair the quality of image, even after a short period of storage / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica
15

Monitoramento de Para-raios de Óxido de Zinco em campo. / Monitoring of Zinc Oxide surge arresters in the field.

LIMA JÚNIOR, Geraldo Bezerra. 21 April 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-21T14:21:51Z No. of bitstreams: 1 GERALDO BEZERRA LIMA JÚNIOR - DISSERTAÇÃO PPGEE 2014..pdf: 4130681 bytes, checksum: 7aa2b6dbcd9d18892be46ec5c14536b6 (MD5) / Made available in DSpace on 2018-04-21T14:21:51Z (GMT). No. of bitstreams: 1 GERALDO BEZERRA LIMA JÚNIOR - DISSERTAÇÃO PPGEE 2014..pdf: 4130681 bytes, checksum: 7aa2b6dbcd9d18892be46ec5c14536b6 (MD5) Previous issue date: 2014-09-02 / Nos dias atuais a confiabilidade e a continuidade no fornecimento de energia elétrica são cada vez mais exigidos. Os para-raios tem uma importante função neste processo que é de proteger os demais equipamentos integrantes da rede elétrica de sobretensões atmosféricas e de manobra. Quando falham, normalmente provocam o desligamento de linhas de transmissão ou de transformadores, penalizando severamente a concessionária pela indisponibilidade ou por multas impostas pela agência reguladora. Como todo equipamento importante para o sistema elétrico, os para-raios necessitam de técnicas eficazes de monitoramento. Na literatura e na indústria podem ser encontradas diversas técnicas, procedimentos ou equipamentos destinados ao seu monitoramento. Todos os procedimentos ou equipamentos possuem suas limitações, vantagens e desvantagens, sejam elas técnicas, econômicas ou operacionais. Visando suplantar algumas das limitações existentes nas técnicas e procedimentos normalmente empregados no setor elétrico, encontrase proposto neste trabalho uma metodologia de análise da condição operacional de para-raios em campo, com base em medições da corrente de fuga total. Com esta metodologia pretende-se minimizar as dificuldades operacionais relacionadas às atividades de monitoramento, uma vez que será medida apenas a corrente de fuga total, diferentemente de técnicas e procedimentos usuais que requerem também a medição da tensão aplicada. Um banco de dados de correntes de fuga foi obtido com medições realizadas em 05 (cinco) subestações. As medições foram agrupadas por modelo/fabricante e tempo de operação dos para-raios. O instrumento de medição utilizado é composto de um amperímetro do tipo alicate e um osciloscópio digital portátil. O processo de medição em campo mostrou-se efetivo e prático devido à facilidade de manuseio do instrumento utilizado. Ensaios em laboratório foram realizados para avaliação da metodologia e dos instrumentos de medição. A partir da base de dados produzida, foi possível com emprego de técnicas de processamento de sinais e estatística, observar o comportamento gaussiano dos dados e o crescimento do valor médio da componente de 3ª harmônica da corrente total em função do tempo de operação, evidenciando, assim, a correlação entre a elevação da corrente de fuga e a diminuição da vida útil dos para-raios. / Nowadays the reliability and continuity in the electricity supply are increasingly required. The surge arresters has an important function in this process, which is to protect the other utility equipment against lightning and switching surges. When they fail, usually causing the shutdown of transmission lines or transformers, severely penalizing the power utility for the unavailability or regulator fines. As any important equipment for the electrical system, surge arresters need effective monitoring techniques. In the literature and industry several techniques, procedures or equipment for their monitoring can be found. All procedures or devices have their limitations, advantages and disadvantages, whether technical, economic or operational. Aiming to overcome some of the limitations in existing techniques and procedures commonly employed in the electrical industry, a methodology for analyzing the surge arrester operational condition based on measurements of total leakage current is proposed in this paper. With this methodology is intended to minimize operational difficulties associated with monitoring activities, since it will only measure the total leakage current unlike the usual techniques and procedures, which require the measurement of the applied voltage, too. A database of leakage currents with measurements performed in five (05) power substations was obtained. Measurements were grouped by arresters model/manufacturer and operation time. The measuring instrument used consists of a clamp type ammeter and a portable digital oscilloscope. The process of field measurement was effective and practical due to the ease of handling of the used instrument. Laboratory tests were performed to evaluate the methodology and measuring instruments. From the database produced, it was possible through the use of techniques of signal processing and statistical observe the Gaussian behavior of the data and the average increase of the 3rd harmonic component of the total current as a function of operating time, which highlights thus, the correlation between the increase of the leakage current and the decrease of the lifetime of the surge arrester.
16

Avaliação objetiva da qualidade do filme Contrast® FV-58 em soluções frescas e degradadas

Carvalho, Fabiano Pachêco de 10 December 2009 (has links)
Made available in DSpace on 2015-05-14T12:56:05Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 1129487 bytes, checksum: 9b4bcacf33a745b3f606911583f777bb (MD5) Previous issue date: 2009-12-10 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The use of intraoral radiographs is quite common in daily practice of dentistry and the radiographic film has been the most used means of capture, disposal and storage of radiographic images. However, X-ray emission can produce deleterious biological effects. One of the easiest ways to reduce the radiation needed to produce radiographs is the use of more sensitive films. The choice of these films is essential, since the radiographic quality is not compromised. The films have different behaviors in the changing of the type of processing, concentration, temperature and state of degradation of processing solutions. This study aimed to evaluate the F-speed film DFL Contrast® FV-58 and compare it with the Kodak Insight® E/F speed film. The parameters studied were the sensitometric properties, the relative contrast and base plus fog density. These parameters were calculated from values of optical density and the sensitometric properties used also measures of radiation dose. In order to observe the behavior of the films in fresh and degraded solutions, a model of degradation was created that lasted four weeks. The quality parameters were measured at five different times and the results showed that the Contrast® film has sensitivity, contrast and base plus fog density significantly higher, whereas the values of latitude are minor. The relative contrast showed no significant difference between the types of film. The degradation time of processing solutions were not significant in the parameters studied. It was concluded that the claims of the manufacturer of the film Contrast® is correct and confirm the characteristics of film, the highest sensitivity and contrast that the Insight® film / A utilização de radiografias intrabucais é bastante comum na prática diária da Odontologia e o filme radiográfico tem sido o meio mais usado de captura, disposição e armazenamento das imagens radiográficas. Entretanto, as radiações X podem produzir efeitos biológicos deletérios. Uma das formas mais simples de reduzir a radiação que chega ao paciente é o uso de filmes mais sensíveis. A escolha desses filmes é essencial, desde que a qualidade radiográfica não seja prejudicada. Os filmes apresentam comportamentos diferentes frente às variações do tipo de processamento, concentração, temperatura e ao estado de degradação de soluções processadoras. O presente estudo teve como objetivo avaliar o filme DFL Contrast® FV-58 de sensibilidade F e compará-lo com o filme Kodak Insight®, de sensibilidade E/F. Os parâmetros estudados foram as propriedades sensitométricas, o contraste relativo e a densidade base e velamento. Esses parâmetros foram calculados a partir de valores de densidade óptica e o cálculo das propriedades sensitométricas também se utilizou de medidas de dose de radiação. Com a finalidade de observar o comportamento dos filmes em soluções frescas e degradadas, foi criado um modelo de degradação que durou quatro semanas. Os parâmetros de qualidade foram medidos em cinco tempos distintos e os resultados mostraram que o filme Contrast® possui valores de sensibilidade, contraste e densidade base e velamento significativamente maiores, enquanto os valores de latitude são menores. O contraste relativo não mostrou diferença significativa entre os tipos de filme. O tempo de degradação das soluções de processamento não mostrou significância nos parâmetros estudados. Concluiu-se que as alegações do fabricante do filme Contrast® estão corretas e confirmam as características desse filme, de maior sensibilidade e contraste que o filme Insight®.
17

Sistemas para detecção e localização de descargas atmosféricas e perdas de cabos para-raios por furto em linhas de transmissão de energia elétrica

SANTOS, Emmanuel Andrade de Barros 29 May 2013 (has links)
Submitted by Amanda Freitas (amanda.freitas@ufpe.br) on 2015-04-17T13:33:05Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) DISSERTAÇÃO Emmanuel Andrade de Barros Santos.pdf: 5505882 bytes, checksum: 3e253365a0c28b99c3572781dd0849cd (MD5) / Made available in DSpace on 2015-04-17T13:33:05Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) DISSERTAÇÃO Emmanuel Andrade de Barros Santos.pdf: 5505882 bytes, checksum: 3e253365a0c28b99c3572781dd0849cd (MD5) Previous issue date: 2013-05-29 / Chesf (Companhia Hidroelétrica do São Francisco); CNPq / A incidência direta ou indireta de descargas atmosférica nas linhas de transmissão e distribuição é um dos grandes problemas que afetam a qualidade do serviço de energia elétrica, gerando danos às linhas de transmissão e distribuição e multas para as companhias elétricas. O evento geralmente causa desligamentos não programados, e a determinação do local na linha de transmissão onde ocorreu tal desligamento não possui atualmente uma precisão satisfatória. Outro problema recorrente são os furtos dos cabos para-raios, que deixam as linhas de transmissão desprotegidas e causam prejuízos financeiros para as companhias. A localização dos pontos onde ocorreram as descargas ou furtos dos cabos é necessária para que as equipes de manutenção possam realizar um serviço mais eficiente e preciso. Esta Dissertação apresenta a concepção, construção e testes de dois sistemas que podem ser implantados nas linhas de transmissão de energia elétrica: um para detecção e localização de descargas atmosféricas, que utiliza sensor de corrente elétrica, circuitos eletrônicos e módulos de comunicação; e outro para detecção e localização de furtos de cabos para-raios, pelo uso de antenas de alta diretividade e módulos de comunicação, cuja metodologia faz uso do espalhamento das ondas eletromagnéticas pelos próprios cabos.
18

Projeto ótico de linha de luz de raios-X duros para cristalografia de proteínas / Optical design of a hard X-ray beamline to protein crystallography

Grizolli, Walan Cesar 16 August 2018 (has links)
Orientador: Antônio Rubens Britto de Castro / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-08-16T08:21:17Z (GMT). No. of bitstreams: 1 Grizolli_WalanCesar_M.pdf: 22164883 bytes, checksum: 87cb39dcd42129ec1d9a3f9ec6fcba09 (MD5) Previous issue date: 2010 / Resumo: Diversas áreas da ciência moderna têm sido beneficiadas pelo uso da radiação síncrotron. As técnicas disponveis em laboratórios deste tipo abrangem pesquisas em ciências básicas como Física, Química e Biologia bem como em áreas como engenharia de materiais e farmacologia. Em particular, o uso do espectro de raios-x duros (8-20keV) das fontes síncrotron atuais e crucial para técnicas estruturais como difração e cristalografia. Estas técnicas estão disponíveis para a comunidade científica brasileira no Laboratório Nacional de Luz Síncrotron (LNLS), cujas linhas de luz estão abertas a usuários externos desde 1997. As instalações do LNLS vem sendo constantemente aperfeiçoadas, permitindo o estudo de novos casos científicos como consequência destas melhorias. Neste trabalho estudamos as propriedades da fonte de radiação síncrotron do LNLS e realizamos um projeto óptico para uma linha de luz direcionada a cristalografia de proteínas. Com uso de simulações computacionais propomos opções para melhoria do fluxo de flotons nas linhas de cristalografia de proteínas já existentes. Nossos estudos apontam para a viabilidade de construção de uma linha lateral a linha de luz MX2, utilizando a mesma fonte Wiggler já instalada, com fluxo proporcional à linha central. / Abstract: Distinct research fields in modern science have taken advantage of synchrotron radiation. The techniques that are available in such laboratories have a very broad scope, ranging from basic sciences such as Physics, Chemistry and Biology, to applied fields as engineering and pharmacology. In particular, the use of hard x-ray spectrum (8-20keV) from modern synchrotron sources is crucial for structural techniques such as diffraction and crystallography. These techniques have been available to the Brazilian scientific community since 1997, when the Brazilian Synchrotron Light Laboratory (LNLS) facilities were opened to external users. The LNLS beamlines have constantly evolved , allowing the users to perform novel experiments as a consequence of instrumental improvements. In this work we study the properties of the LNLS sources and propose solutions for the optics of a beamline dedicated to protein crystallography. By using computer simulations we propose options to enhance the photon flux in the pre-existing protein crystallography beamlines. Our results point out to the feasibility of a lateral beamline using the MX2 wiggler source, with similar flux to the central beamline. / Mestrado / Física / Mestre em Física
19

Estudo de metodologia para modelagem e simulação de tensões induzidas de origem atmosférica em linhas de distribuição protegidas por para-raios de \'ZN\'O\' / Study of methodology for modeling and simulation of induced voltages of atmospheric origin in distribution lines protected by \'ZN\'O\' surge arresters

Araújo, Marcel Ayres de 18 July 2013 (has links)
As tensões induzidas e sobretensões geradas por descarga atmosféricas diretas e indiretas são um dos principais causadores de desligamentos não programados em redes de transmissão e distribuição. Estes desligamentos comprometem o fornecimento de energia a milhares de consumidores, sobretudo em regiões com constantes variações climáticas e com características orográficas bastante diversificadas, como apresentado no território brasileiro. Desse modo, cada vez mais esses fenômenos são estudados a fim de desenvolverem-se procedimentos para proteção contra distúrbios causados por descargas atmosféricas. Neste contexto, esta pesquisa contempla o estudo do estabelecimento das descargas atmosféricas indiretas e das tensões por elas induzidas em linhas de distribuição, assim como o assentamento das mesmas nestas redes de energia. Não obstante, utilizando-se um software capaz de representar transitórios eletromagnéticos são modelados e implementados um alimentador teste de distribuição e um sistema para estimação de tensões induzidas no domínio do tempo baseado no modelo de Sune Rusck. Também são modelados e implementados para-raios de óxido de zinco, de forma a representar suas características dinâmicas, para proteger a linha sob apreciação dos distúrbios provocados pelas tensões induzidas. A partir de uma análise comparativa entre a operação do sistema de distribuição em regime permanente e frente aos desdobramentos promovidos pelas tensões induzidas, é determinada a melhor configuração, localização e quantificação dos para-raios a serem instalados para proteção do sistema teste. Por meio da avaliação dos resultados das simulações computacionais observa-se a robustez da subestação e quais os ramos e cargas mais suscetíveis a perturbações frente às tensões induzidas, bem como a maior proteção oferecida pelos para-raios aos elementos conectados próximos aos seus nós de alocação. / The induced voltages and overvoltages generated by direct and indirect lightning are a major cause of not programmed shutdowns in transmission and distribution networks. These shutdowns compromise the power supply of thousands of consumers, especially in regions with frequent climatic variations and quite diverse orographic characteristics, as occurred on Brazilian soil. Thus, these phenomena are more and more studied in order to develop procedures for protection against disturbances caused by lightning. In this context, this research focuses on the study of the establishment of indirect lightning and the voltage induced by them on distribution lines, as well as their settlement on energy networks. However, using a software able to represent electromagnetic transients, a distribution test feeder and a system for estimating induced voltages in the time domain based on the Sune Rusck model are modeled and implemented. In addition, metal oxide surge arresters are modeled and implemented to represent its dynamic characteristics, in order to protect the line under consideration of disturbances caused by induced voltages. From a comparative analysis between the operation of the distribution system in steady state and facing the developments promoted by induced voltages, it is determined the best configuration, as well as the location and quantification of the surge arrester to be installed to protect the test system. Through evaluation of the results of computer simulations, it is observed the robustness of the substation and which branches and loads are more susceptible to the disturbances facing the induced voltages, and the greater protection offered by the surge arresters elements connected near to its nodes allocation.
20

Metodologia para o diagnóstico em tempo real de para-raios em sistemas de distribuição e transmissão de energia elétrica / Methodology for Real Time Diagnostic of Surge Arresters in Electric Energy Distribution and Transmission Systems

Alves, Marcos Eduardo Guerra 08 November 2013 (has links)
Dada a importância dos para-raios para a proteção dos diversos equipamentos e instalações nos sistemas de distribuição e transmissão de energia elétrica contra danos provocados por sobretensões transitórias, quer sejam originadas por descargas atmosféricas, quer por estabelecimento e interrupção de cargas reativas (sobretensões de manobra), é apresentada uma nova metodologia de diagnóstico de seu estado. São apresentadas também as formas construtivas dos para-raios com tecnologias de carboneto de silício (SiC) e óxido de zinco (ZnO), as quais são associadas a modelos elétricos de representação completos e simplificados, de forma a facilitar a análise dos métodos de diagnóstico. Os métodos atualmente empregados para o diagnóstico dos para-raios, tanto fora de serviço quanto durante a operação, bem como suas potencialidades e pontos falhos são explanados, para os equipamentos de SiC e de ZnO. O novo método de diagnóstico proposto nesse trabalho é introduzido a seguir, baseado na monitoração da capacitância equivalente e resistência equivalente do para-raio, juntamente com simulações dos diversos tipos de defeitos passíveis de ocorrência em equipamentos de SiC e ZnO, verificando-se os parâmetros de medição afetados por cada um deles, de forma a estabelecer a efetividade do novo método de monitoração para a detecção dos defeitos. Também é apresentado um método para viabilização da monitoração em tempo real de capacitância e de resistência equivalentes, através da técnica de soma vetorial das correntes de fuga, atualmente já empregada para monitoração de buchas capacitivas de transformadores e outros equipamentos. Por fim, são apresentados os resultados esperados com o novo método de monitoração e as sugestões de novas etapas para trabalhos futuros. / Given the importance of surge arresters for the protection of several devices and installations in electric energy distribution and transmission systems from damages caused by transitory overvoltages, either originated from atmospheric discharges or by closing or opening of reactive loads (switching overvoltages), a new methodology for diagnosing their condition is presented. The constructive forms of surge arresters with silicon carbide (SiC) and zinc oxide (ZnO) technologies are presented, as well as their associated electric representation models, complete and simplified, so as to facilitate the analysis of diagnostic methods. Surge arrester diagnostic methods are presented, both off-line and on-line, together with their potentialities and weak points, for SiC and ZnO arresters. The new diagnostic method proposed in this work is introduced next, based on monitoring of the arrester equivalent capacitance and equivalent resistance, followed by simulations of the several possible defect types in SiC and ZnO devices. The measured parameters affected by each defect type are checked in order to establish the effectiveness of the new monitoring method for the detection of arrester problems. A method for making the monitoring of equivalent capacitance and resistance is also presented, by using the vector sum of leakage currents technique, largely used for monitoring of capacitive bushings in power transformers and other equipment. Finally, the results expected with the new monitoring method and suggestions for future work are presented.