• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 453
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 465
  • 465
  • 372
  • 367
  • 156
  • 87
  • 86
  • 80
  • 79
  • 76
  • 71
  • 69
  • 68
  • 65
  • 62
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
431

Avaliação do trauma intracoclear causado pela inserção do feixe de eletrodos do implante coclear via fossa média em ossos temporais / Evaluation of intra cochlear trauma after cochlear implant electrode insertion through a middle fossa approach in temporal bones

Juan Carlos Cisneros Lesser 01 February 2017 (has links)
Introdução: O acesso pela via da fossa craniana média para colocação do implante coclear provou ser uma alternativa valiosa em pacientes com otite média crônica e cavidades de mastoidectomia instáveis, cócleas parcialmente ossificadas e em alguns casos de displasia do ouvido interno. Até hoje não existem pesquisas que descrevam se a inserção do feixe de eletrodos pela via da fossa média pode ser feita com um mínimo de traumatismo intracoclear, comparável ao observado nas inserções pela janela redonda. Objetivo: Avaliar o trauma intracoclear com dois modelos distintos de implante quando o feixe de eletrodos é inserido por cocleostomia na fossa craniana média em ossos temporais. Método: 20 ossos temporais retirados antes de 24 horas pós-óbito, foram implantados através do local da cocleostomia no giro basal da cóclea identificado no assoalho da fossa cerebral média. Dez peças receberam um implante reto e dez um pré-curvado, e foram fixadas em resina epóxi. Foi realizada tomografia computadorizada para determinar a colocação adequada do feixe eletrodos, profundidade de inserção e a distância entre a janela redonda e a cocleostomia. Por último, as peças foram polidas em série, tingidas e visualizadas por estereomicroscópio para avaliar a posição do feixe e trauma intracoclear. Resultados: A tomografia mostrou um posicionamento intracoclear do feixe de eletrodos nas 20 peças. No grupo dos implantes retos a média de eletrodos inserido foi 12,3 (10 a 14) e dos pré-curvados 15,1 (14 a 16) com uma diferença significativa (U=78, p=0,0001). A mediana de profundidade de inserção foi maior para o eletrodo pré-curvado (14,5mm) que para o reto (12,5mm) com diferenças estatisticamente significativas (U = 66, p = 0,021). Só uma das 20 inserções foi atraumática e 70% tiveram graus de trauma altos (grau 3 ou 4). Não foram observadas diferenças significativas do grau de trauma entre os dois tipos de feixes nem quando as inserções foram no sentido da janela redonda, comparado com o sentido do giro médio. Conclusões: A técnica cirúrgica utilizada permitiu a inserção do feixe de eletrodos na cóclea em todas as peças, porém sem garantir uma inserção na escala timpânica e com alto risco de trauma nas microestruturas da cóclea / Introduction: In recent years, a middle fossa approach has been described for the insertion of cochlear implants, and it proved to be a reliable alternative for implantation in patients with chronic supurative otitis media, unstable mastoid cavities with recurrent otorrhea, partially ossified cochlea and in some cases of inner ear dysplasia. Until now, no research has been done to describe if this approach allows for anatomic preservation and non-traumatic insertions comparable to those through the round window. Objective: To evaluate cochlear trauma when the cochlear implant electrode is inserted through a middle fossa approach by means of histologic and imaging studies in temporal bones. Methods: 20 temporal bones retrieved before 24 hours after death were implanted through a middle cranial fossa cochleostomy in the basal turn of the cochlea. Ten received a straight electrode and 10 a perimodiolar electrode. After reducing the bone size with preservation of the inner ear structures, the temporal bones were fixed, dehydrated and embedded in an epoxy resin. CT scans were performed to determine if an adequate direction of insertion was attained, the depth of insertion and the distance between the cochleostomy and the round window. At last, the samples were polished by micro-grinding technique and microscopically visualized to evaluate intracochlear trauma. Results: The CT-scan showed an adequate intracoclear position of the electrode in all the samples. In the straight electrode group the average number of inserted electrodes was 12.3 (10 to 14) against 15.1 (14- 16) for the perimodiolar (U=78, p=0.0001). The median depth of insertion was significantly larger for the perimodiolar electrode group (14.4mm vs. 12.5mm U=66, p = 0.021). Only one atraumatic insertion was achieved and 70% of the samples had important trauma (grades 3 and 4). No differences were identified for the trauma grades between the two groups of electrodes. Also, there were no differences in trauma if the cochlear implants were inserted in the direction of the basal turn of the cochlea or in the direction of the middle and apical turns. Conclusions: The surgical technique that was used allowed for a proper intracochlear insertion of the electrodes in all 20 temporal bones but it does not guarantee a correct scala tympani position and carries high trauma risk for the intracochlear microstructures
432

Implante auditivo de tronco encefálico em pacientes com perda auditiva neurossensorial profunda por meningite e ossificação coclear total bilateral / Auditory brainstem implant in patients with post-meningitis profound sensorineural hearing loss and totally ossified cochleae

Malerbi, Andréa Felice dos Santos 01 June 2017 (has links)
Introdução: O implante auditivo de tronco encefálico (ABI) é indicado para pacientes com perda auditiva neurossensorial severa a profunda quando há impossibilidade de realização do implante coclear. Em pacientes com surdez por meningite e ossificação coclear total bilateral, o ABI é a opção para a reabilitação auditiva. Objetivos: O estudo tem por objetivo avaliar a contribuição do ABI para os limiares audiométricos e para a percepção de fala após no mínimo 12 meses de uso em pacientes com ossificação coclear total por surdez pós-meningite, bem como descrever as complicações do procedimento. Material e métodos: Dez pacientes com surdez pósmeningite foram submetidos ao ABI por via retrolabiríntica ampliada em um centro terciário de assistência e ensino. Todos os pacientes foram operados pela mesma equipe cirúrgica e a avaliação audiológica foi realizada pelo mesmo fonoaudiólogo. Foram realizados audiometria tonal e testes de percepção de fala no pré-operatório e no mínimo 12 meses após a ativação do implante. Foram descritas as complicações associadas ao procedimento. Resultados: Oito de dez pacientes implantados permaneceram usuários. Dois pacientes não apresentaram respostas auditivas e abandonaram o seguimento. Os oito pacientes apresentaram melhora estatisticamente significativa nos limiares audiométricos, bem como nos testes de discriminação de palavras e vogais comparando pré e pós-operatório com média de seguimento de 3,3 anos. Em dois pacientes, a discriminação de sentenças em formato fechado somente no modo auditivo foi de 30% e 40%. Todos os oito usuários referiram benefício com o uso do ABI. Não houve complicações relacionadas ao procedimento. Conclusão: O ABI via retrolabiríntica ampliada é uma opção terapêutica segura para pacientes com surdez pós-meningite e com presença de ossificação coclear total bilateral, contribuindo para melhora nos limiares audiométricos e nos testes de percepção de fala. Embora a melhora nos testes audiológicos seja inferior à do implante coclear, a maioria dos pacientes do estudo usa o ABI diariamente por um período superior a 8 horas e refere benefício em seu cotidiano / Introduction: The Auditory Brainstem Implant (ABI) is an option to auditory restoration in patients with severe to profound sensorineural hearing loss who cannot be fitted with a cochlear implant. This is the only option in patients with post meningitis hearing loss presenting with bilateral total cochlear ossification. Objectives: The main objective of the study is to evaluate the hearing contribution in audiometry and speech perception tests at least 12 months after ABI implantation in patients with post-meningitis profound hearing loss. The complications of the procedure were also described. Materials and Methods: Ten patients with post-meningitis hearing loss went an ABI through extended retrolabyrinthine approach in a tertiary center by the same surgeons. The same audiologist was responsible for audiological follow-up. Tonal audiometry and speech perception tests were made before and at least 12 months after the ABI activation. The procedure complications were described for all patients. Results: Eight of ten patients became ABI users. Two patients had no auditory response and abandoned the treatment. Eight users showed benefit in tonal audiometry, word and vowels perception tests after an average follow up of 3.3 years. Two patients were able to recognize 30 and 40% of closed sentences without lip reading. There were no complications due to the ABI procedure. Conclusion: The extended retrolabyrinthine approach for the ABI is a safe surgical option for patients with post-meningitis hearing loss and totally ossified cochleae. It contributes to hearing performance in audiometry and speech perception tests. Even though the ABI results are poorer than the cochlear implants, in this study the majority of patients use their ABI more than eight hours a day and report benefits in daily activities
433

Efeito do silenciamento gênico do Tnfa na preservação auditiva em ratos Wistar expostos ao ruído e análise da expressão gênica dessa via metabólica / Effect of Tnfa gene silencing on auditory preservation in Wistar rats exposed to noise and analysis of gene expression of this metabolic pathway

Rodrigues, Janaina Candida 23 May 2018 (has links)
INTRODUÇÃO: A exposição a níveis elevados de pressão sonora é a segunda causa mais comum de perda auditiva sensorioneural adquirida. Está relacionada à morte celular por apoptose, necrose e/ou necrose programada (necroptose) devido ao dano mecânico e/ou metabólico, ocasionando a degeneração de estruturas cocleares como células ciliadas, sobretudo externas, células de suporte e de fibras aferentes do nervo coclear. Estudos têm demostrado um aumento na citocina inflamatória TNFa após a exposição ao ruído, bem como a melhoria auditiva relacionada ao uso de etanercepte, que é um bloqueador destacitocina. Neste contexto, este estudo teve por objetivo avaliar o efeito do silenciamento gênico do Tnfa na audição de ratos Wistar, expostos ao ruído branco, e identificar o perfil de expressão gênica na via metabólica desse gene. METODOLOGIA: Foram incluídos ratos Wistar do sexo masculino, jovens com limiar auditivo no Peate clique de 50 dBSPL. Os animais foram submetidos à introdução do siRNA Tnfa em uma orelha, e siRNA scramble na orelha contralateral por via trans-timpânica com posterior exposição à 120 dBSPL de ruído branco por 3h. Foi realizado Peate clique e remoção das cócleas para obtenção do cDNA e avaliação da expressão gênica da via metabólica do Tnfa por meio de qRT-PCR. Um grupo de animais, não submetidos ao silenciamento, foi exposto ao ruído para análise dessa via metabólica. Para o cálculo da expressão gênica relativa (Rq) utilizamos o método do deltaCT comparativo e o teste t-Student pareado para avaliar os parâmetros no Peate clique. RESULTADOS: A taxa de silenciamento observada foi de 74,1%. A média do limiar eletrofisiológico nas orelhas silenciadas foi estaticamente melhor que a orelha scramble (p < 0,001) com valores médios de 49,5 +- 10.5. A amplitude média da onda I em 80 dBSPL e das ondas II e IV em 90 dBSPL foi estatisticamente maior na orelha siRNA Tnfa, sem alteração na latência nas intensidades audíveis,para ambos os lados. A exposição ao ruído promoveu aumento da expressão do gene Tnfa e de seu receptor Tnfrsf1A, 24h após à exposição, associado ao aumento da expressão de genes relacionados à apoptose e diminuição de genes relacionados à sobrevida celular. CONCLUSÃO: O ruído promoveu aumento de expressão do gene Tnfa e de genes envolvidos na apoptose, associado à perda auditiva em modelo experimental. A administração trans-timpânica do siRNA Tnfa promoveu preservação do limiar eletrofisiológico e da amplitude da onda I, II e IV no Peate clique, após exposição ao ruído intenso, sugerindo que a inibição deste pode ser uma estratégia de preservação auditiva promissora. O silenciamento do Tnfa inibiu a disfunção coclear após estímulo acústico, sugerindo que esta proteína é um dos principais agentes envolvidos na perda auditiva induzida pelo ruído, devendo ser considerada como alvo terapêutico na estratégia de preservação auditiva / INTRODUCTION: Exposure to high levels of sound pressure is the second most common cause of acquired sensorineural hearing loss. It is related to cell death through apoptosis, necrosis and/or programmed necrosis (necroptosis) due to mechanical and/or metabolic damage, causing the degeneration of cochlear structures, such as cilliary cells, mainly external, as well as support cells and afferent fibers of the cochlear nerve. Studies have demonstrated an increase in the inflammatory cytokine TNFalfa after exposure to noise, as well as auditory improvement related to the use of etanercept, a cytokine blocker. In this context, this study aimed to evaluate the effect of Tnfa gene silencing on the hearing of Wistar rats exposed to white noise and to identify the expression profile in the metabolic pathway of this gene. METHODOLOGY: Young male Wistar rats with 50 dBSPL threshold in auditory brainstem responses click (ABR) were included in this study and submitted to the introduction of the TnfasiRNA in one ear and the scramble siRNA in the contralateral ear by trans-tympanic route, with subsequent exposure to 120 dB SPL of white noise for 3h. ABR was measured and the cochleae were dissected and used for the extraction of total RNA to obtain cDNA and conduct evaluations of the Tnfa metabolic pathway gene expression by qRT-PCR. A group of animals, not submitted to silencing, was exposed to noise to analyze this metabolic pathway. The relative gene expression (Rq) was calculated by the comparative deltaCT method and the paired Student t-test were applied to evaluate the parameters of the ABR click. RESULTS: The silencing rate was 74.1%. The mean electrophysiological threshold in the silenced ears was statistically higher than the scrambled ear (p < 0.001) with mean values of 49.5 +- 10.5. The mean amplitudes of wave I at 80 dBSPL and waves II and IV at 90dBSPL were statistically higher in the TnfasiRNA ear, with no change in latency at audible intensities for both sides. Noise exposure promoted increased expression of the Tnfa gene and its receptor, Tnfrsf1A, 24h after exposure, associated with increased expression of genes related to apoptosis and decreased expression of genes related to cell survival. CONCLUSIONS: Noise exposure promoted increased in Tnfa gene expression as well as in genes involved in apoptosis, associated with hearing loss in an experimental model. The trans-tympanic administration of TnfasiRNA promotes the preservation of the electrophysiological threshold and the amplitude of wave I, II and IV in the ABR click, after exposure to intense noise, suggesting that this inhibition may be a promising auditory preservation strategy. The Tnfa knockdown inhibited cochlear dysfunction after acoustic injury, suggesting that this protein plays an important role in noise induced hearing loss and should be considered a therapeutic target in auditory preservation strategies
434

Comparação entre respostas auditivas de estado estável e avaliação comportamental em crianças candidatas ao implante coclear / Comparison between Auditory Steady-State Responses and behavioral audiometry in pediatric cochlear implant candidates

Beck, Roberto Miquelino de Oliveira 26 May 2015 (has links)
INTRODUÇÃO: As Respostas Auditivas de Estado Estável permitem avaliação frequência específica em intensidades de até 120 dB NA e a detecção de audição residual em pacientes com perda auditiva severo-profunda. O objetivo deste estudo é comparar os limiares à RAEE e os resultados da avaliação comportamental em crianças com suspeita de surdez severo-profunda. MÉTODO: Estudo transversal para comparar respostas à RAEE e por audiometria com reforço visual (VRA) em 63 crianças candidatas ao implante coclear (126 orelhas) com idade entre 6 e 72 meses. Foram incluídas crianças com otomicroscopia normal, ausência de respostas ao PEATE clique a 90 dB NA e às emissões otoacústicas. Foram excluídas crianças com malformações de orelha interna, doenças do espectro da neuropatia auditiva, ou que não completaram a avaliação comportamental ou não atingiram ruído eletroencefalográfico < 30 nV durante a RAEE. Foram utilizados estímulos com tons contínuos sinusoidais (100% AM e 20% FM) nas frequências de 500, 1000, 2000 e 4000 Hz em intensidade máxima de 110 dB NA. Os limiares à VRA foram obtidos por tom warble nas frequências de 500, 1000, 2000 e 4000 Hz em cada orelha através de fones de inserção (ER-5A) ou tipo casco (TDH-39). A intensidade máxima de estimulação foi de 120 dB NA em cada frequência. RESULTADOS: Limiares comportamentais foram obtidos em 36,7% (185/504) de todas as frequências em todas as crianças, 9% em intensidade maior que 110 dB NA. Entre as 504 medidas da RAEE em 63 indivíduos, 53 limiares foram obtidos (10,5%). Ao todo, 89,5% das frequências testadas não apresentaram nenhuma resposta em 110 dB NA. A distribuição dos limiares à RAEE foi semelhante à da avaliação comportamental. A maioria das respostas foram em 500 Hz, diminuindo nas frequências agudas. A diferença média entre os limiares à VRA e à RAEE variou entre 0,09 e 8,94 dB. Foram realizadas 27 comparações entre RAEE e VRA: 12 em 500 Hz, 9 em 1000 Hz, 5 em 2000 Hz e 1 em 4000 Hz. Respostas ausentes foram observadas em ambos os testes em 38,1% em 0,5 KHz, 52,45% em 1 KHz, 74,6% em 2 KHz e 81,0% em 4 KHZ. A especificidade foi > 90% em 1, 2 e 4 KHz. Nas orelhas sem resposta comportamental em 120 dB NA, todos os limiares à RAEE estavam na faixa de perda profunda, 90% deles > 110 dB NA. CONCLUSÃO: A ausência de respostas nas altas intensidades na RAEE foi o principal achado (especificidade > 90%) o que prediz limiares comportamentais na faixa de surdez profunda / Introduction and Objective: ASSR allows frequency-specific evaluation in intensities up to 120 dB HL and detection of residual hearing in patients with severe-toprofound hearing loss. The aim of this study was to compare ASSR thresholds and behavioral test results in children with suspected severe-to-profound hearing loss. Methods: A cross sectional study was carried out to compare ASSR and Visual Reinforcement Audiometry (VRA) responses in 63 pediatric cochlear implant candidates (126 ears) aged between 6 to 72 months. We included children with normal otomicroscopy findings, absent responses to click-ABR at 90 dB HL and otoaccoustic emissions. We excluded children with inner ear malformations, auditory neuropathy spectrum disorder or who did not complete VRA or achieve EEG noise < 30 nV during the ASSR test. Air-conduction ASSR stimuli were continuous sinusoidal tones (100% AM and 20% FM) presented at 0.5, 1, 2 and 4 kHz starting at the maximum presentation level of 110 dB HL. VRA thresholds were acquired with warble tones presented at 0.5, 1, 2 and 4 KHz in each ear through ER-tone 5A or TDH-39 phones. Maximum presentation level was 120 dB HL for each frequency. Results: Behavioral thresholds were obtained in 36.7% (185/504) of all frequencies in all subjects, 9% were in intensities > 110 dB HL. Among 504 ASSR measurements from 63 subjects, 53 thresholds were obtained (10.5%). Overall 89.5% of the tested frequencies did not show any response at 110 dB HL. The distribution of ASSR responses was similar to the behavioral test results. Most responses were at 500 Hz, decreasing among the higher frequencies. Mean differences between behavioral and ASSR thresholds varied from 0.09 to 8.94 dB. Overall, 27 comparisons of behavioral and ASSR thresholds were obtained: 12 at 0.5 KHz, 9 at 1 KHz, 5 at 2 KHz and 1 at 4 KHz. Absent responses were observed in both tests in 38.1% at 0.5 KHz, 52.4% at 1 KHz, 74.6% at 2 KHz and 81.0% at 4 KHz. The specificity was > 90% at 1, 2 and 4 KHz. In ears with no behavioral response at 120 dB HL all ASSR thresholds were in the profound hearing loss range, 90% of them were equal or > than 110 dB HL. Conclusion: Among 63 pediatric CI candidates, absent responses to high-intensity ASSR was the major finding (specificity > 90%) predicting behavioral thresholds in the profound hearing loss range. These findings can be helpful to confirm the decision for cochlear implantation
435

Análise molecular dos genes NEUROD4, FGFR1 e PROKR2 em pacientes com hipopituitarismo congênito / Comparison between Auditory Steady-State Responses and behavioral audiometry in pediatric cochlear implant candidates

Correa, Fernanda de Azevedo 28 May 2015 (has links)
INTRODUÇÃO: As Respostas Auditivas de Estado Estável permitem avaliação frequência específica em intensidades de até 120 dB NA e a detecção de audição residual em pacientes com perda auditiva severo-profunda. O objetivo deste estudo é comparar os limiares à RAEE e os resultados da avaliação comportamental em crianças com suspeita de surdez severo-profunda. MÉTODO: Estudo transversal para comparar respostas à RAEE e por audiometria com reforço visual (VRA) em 63 crianças candidatas ao implante coclear (126 orelhas) com idade entre 6 e 72 meses. Foram incluídas crianças com otomicroscopia normal, ausência de respostas ao PEATE clique a 90 dB NA e às emissões otoacústicas. Foram excluídas crianças com malformações de orelha interna, doenças do espectro da neuropatia auditiva, ou que não completaram a avaliação comportamental ou não atingiram ruído eletroencefalográfico < 30 nV durante a RAEE. Foram utilizados estímulos com tons contínuos sinusoidais (100% AM e 20% FM) nas frequências de 500, 1000, 2000 e 4000 Hz em intensidade máxima de 110 dB NA. Os limiares à VRA foram obtidos por tom warble nas frequências de 500, 1000, 2000 e 4000 Hz em cada orelha através de fones de inserção (ER-5A) ou tipo casco (TDH-39). A intensidade máxima de estimulação foi de 120 dB NA em cada frequência. RESULTADOS: Limiares comportamentais foram obtidos em 36,7% (185/504) de todas as frequências em todas as crianças, 9% em intensidade maior que 110 dB NA. Entre as 504 medidas da RAEE em 63 indivíduos, 53 limiares foram obtidos (10,5%). Ao todo, 89,5% das frequências testadas não apresentaram nenhuma resposta em 110 dB NA. A distribuição dos limiares à RAEE foi semelhante à da avaliação comportamental. A maioria das respostas foram em 500 Hz, diminuindo nas frequências agudas. A diferença média entre os limiares à VRA e à RAEE variou entre 0,09 e 8,94 dB. Foram realizadas 27 comparações entre RAEE e VRA: 12 em 500 Hz, 9 em 1000 Hz, 5 em 2000 Hz e 1 em 4000 Hz. Respostas ausentes foram observadas em ambos os testes em 38,1% em 0,5 KHz, 52,45% em 1 KHz, 74,6% em 2 KHz e 81,0% em 4 KHZ. A especificidade foi > 90% em 1, 2 e 4 KHz. Nas orelhas sem resposta comportamental em 120 dB NA, todos os limiares à RAEE estavam na faixa de perda profunda, 90% deles > 110 dB NA. CONCLUSÃO: A ausência de respostas nas altas intensidades na RAEE foi o principal achado (especificidade > 90%) o que prediz limiares comportamentais na faixa de surdez profunda / Introduction and Objective: ASSR allows frequency-specific evaluation in intensities up to 120 dB HL and detection of residual hearing in patients with severe-toprofound hearing loss. The aim of this study was to compare ASSR thresholds and behavioral test results in children with suspected severe-to-profound hearing loss. Methods: A cross sectional study was carried out to compare ASSR and Visual Reinforcement Audiometry (VRA) responses in 63 pediatric cochlear implant candidates (126 ears) aged between 6 to 72 months. We included children with normal otomicroscopy findings, absent responses to click-ABR at 90 dB HL and otoaccoustic emissions. We excluded children with inner ear malformations, auditory neuropathy spectrum disorder or who did not complete VRA or achieve EEG noise < 30 nV during the ASSR test. Air-conduction ASSR stimuli were continuous sinusoidal tones (100% AM and 20% FM) presented at 0.5, 1, 2 and 4 kHz starting at the maximum presentation level of 110 dB HL. VRA thresholds were acquired with warble tones presented at 0.5, 1, 2 and 4 KHz in each ear through ER-tone 5A or TDH-39 phones. Maximum presentation level was 120 dB HL for each frequency. Results: Behavioral thresholds were obtained in 36.7% (185/504) of all frequencies in all subjects, 9% were in intensities > 110 dB HL. Among 504 ASSR measurements from 63 subjects, 53 thresholds were obtained (10.5%). Overall 89.5% of the tested frequencies did not show any response at 110 dB HL. The distribution of ASSR responses was similar to the behavioral test results. Most responses were at 500 Hz, decreasing among the higher frequencies. Mean differences between behavioral and ASSR thresholds varied from 0.09 to 8.94 dB. Overall, 27 comparisons of behavioral and ASSR thresholds were obtained: 12 at 0.5 KHz, 9 at 1 KHz, 5 at 2 KHz and 1 at 4 KHz. Absent responses were observed in both tests in 38.1% at 0.5 KHz, 52.4% at 1 KHz, 74.6% at 2 KHz and 81.0% at 4 KHz. The specificity was > 90% at 1, 2 and 4 KHz. In ears with no behavioral response at 120 dB HL all ASSR thresholds were in the profound hearing loss range, 90% of them were equal or > than 110 dB HL. Conclusion: Among 63 pediatric CI candidates, absent responses to high-intensity ASSR was the major finding (specificity > 90%) predicting behavioral thresholds in the profound hearing loss range. These findings can be helpful to confirm the decision for cochlear implantation
436

Implante auditivo de tronco encefálico em pacientes com perda auditiva neurossensorial profunda por meningite e ossificação coclear total bilateral / Auditory brainstem implant in patients with post-meningitis profound sensorineural hearing loss and totally ossified cochleae

Andréa Felice dos Santos Malerbi 01 June 2017 (has links)
Introdução: O implante auditivo de tronco encefálico (ABI) é indicado para pacientes com perda auditiva neurossensorial severa a profunda quando há impossibilidade de realização do implante coclear. Em pacientes com surdez por meningite e ossificação coclear total bilateral, o ABI é a opção para a reabilitação auditiva. Objetivos: O estudo tem por objetivo avaliar a contribuição do ABI para os limiares audiométricos e para a percepção de fala após no mínimo 12 meses de uso em pacientes com ossificação coclear total por surdez pós-meningite, bem como descrever as complicações do procedimento. Material e métodos: Dez pacientes com surdez pósmeningite foram submetidos ao ABI por via retrolabiríntica ampliada em um centro terciário de assistência e ensino. Todos os pacientes foram operados pela mesma equipe cirúrgica e a avaliação audiológica foi realizada pelo mesmo fonoaudiólogo. Foram realizados audiometria tonal e testes de percepção de fala no pré-operatório e no mínimo 12 meses após a ativação do implante. Foram descritas as complicações associadas ao procedimento. Resultados: Oito de dez pacientes implantados permaneceram usuários. Dois pacientes não apresentaram respostas auditivas e abandonaram o seguimento. Os oito pacientes apresentaram melhora estatisticamente significativa nos limiares audiométricos, bem como nos testes de discriminação de palavras e vogais comparando pré e pós-operatório com média de seguimento de 3,3 anos. Em dois pacientes, a discriminação de sentenças em formato fechado somente no modo auditivo foi de 30% e 40%. Todos os oito usuários referiram benefício com o uso do ABI. Não houve complicações relacionadas ao procedimento. Conclusão: O ABI via retrolabiríntica ampliada é uma opção terapêutica segura para pacientes com surdez pós-meningite e com presença de ossificação coclear total bilateral, contribuindo para melhora nos limiares audiométricos e nos testes de percepção de fala. Embora a melhora nos testes audiológicos seja inferior à do implante coclear, a maioria dos pacientes do estudo usa o ABI diariamente por um período superior a 8 horas e refere benefício em seu cotidiano / Introduction: The Auditory Brainstem Implant (ABI) is an option to auditory restoration in patients with severe to profound sensorineural hearing loss who cannot be fitted with a cochlear implant. This is the only option in patients with post meningitis hearing loss presenting with bilateral total cochlear ossification. Objectives: The main objective of the study is to evaluate the hearing contribution in audiometry and speech perception tests at least 12 months after ABI implantation in patients with post-meningitis profound hearing loss. The complications of the procedure were also described. Materials and Methods: Ten patients with post-meningitis hearing loss went an ABI through extended retrolabyrinthine approach in a tertiary center by the same surgeons. The same audiologist was responsible for audiological follow-up. Tonal audiometry and speech perception tests were made before and at least 12 months after the ABI activation. The procedure complications were described for all patients. Results: Eight of ten patients became ABI users. Two patients had no auditory response and abandoned the treatment. Eight users showed benefit in tonal audiometry, word and vowels perception tests after an average follow up of 3.3 years. Two patients were able to recognize 30 and 40% of closed sentences without lip reading. There were no complications due to the ABI procedure. Conclusion: The extended retrolabyrinthine approach for the ABI is a safe surgical option for patients with post-meningitis hearing loss and totally ossified cochleae. It contributes to hearing performance in audiometry and speech perception tests. Even though the ABI results are poorer than the cochlear implants, in this study the majority of patients use their ABI more than eight hours a day and report benefits in daily activities
437

Distúrbios de audição e a classificação internacional de funcionalidade, incapacidade e saúde / Hearing disorders and the international classification of functioning, disability and health

Costa, Thelma Regina da Silva 27 May 2013 (has links)
Made available in DSpace on 2016-04-27T18:12:01Z (GMT). No. of bitstreams: 1 Final para biblioteca.pdf: 517561 bytes, checksum: 8ada3b8358b7ff570de6993d1d52b7c9 (MD5) Previous issue date: 2013-05-27 / Introduction: the International Classification of Functioning, Disability and Health offers a positive outlook of categorization to the individual that presents changes on function and/or of the structure of the body. Aims to describe the nature and severity of the limitations of functionality (OMS 2011). It is used as a statistical tool, clinical, educational, research and social policy. This classification has been incorporated and used in the sectors of health and multidisciplinary teams. Objective: to verify the applicability of the Hearing Handicap Inventory for the Elderly, to classify individuals according to the categories of the International Classification of Functioning, Disability and Health; establish the categories of the International Classification of Functioning, Disability and Health to individuals who have hearing loss and investigate the prevalence of changes to functionality in individuals with hearing loss. Method: it was applied the Hearing Handicap Inventory for the Elderly and then select the categories of the International Classification of Functioning, Disability and Health. Results: 44.83% showed severe perception of its inability. 62.1% presented: moderate hearing loss that affects the body's functions, the mental functions, perception and hearing (cod b1560.1), moderate hearing loss that affects the body's functions, sensory functions, the auditory functions and the detection of sound (cod b2300.1), qualitative change in the structure of the inner ear, in this case being characterized as sensorioneural bilateral moderate hearing loss (cod s2609.173); 62.1% does not present difficulty for situations involving conversation activities with the family (cod d 3508.0_); 58.6% does not present difficulty in hearing functions of auditory discrimination (cod b2308.0); 69.0% presents much difficulty to hear in their participation activities (cod d115.4 _), does not present difficulty in controlling emotions and impulses in complex personal interactions (cod d7202.0_), does not present difficulty to attend religious services (cod d 9309.0_); 51.7% presents great difficulties to participate in community life when it comes to ceremonies (cod d 9102.4_). Conclusion: the ICF offers important applicability to categorize individuals with hearing loss; the questionnaire used is partially applicable to classify on a complete form, the disabilities of the subjects with hearing loss / a Classificação Internacional de Funcionalidade, Incapacidade e Saúde propõe uma perspectiva positiva de categorização para o indivíduo que apresenta alterações de função e/ou da estrutura do corpo. Tem como objetivo descrever a natureza e a gravidade das limitações de funcionalidade (OMS 2011). Ë utilizada como uma ferramenta estatística, de pesquisa, clínica, pedagógica e de política social. Esta classificação vem sendo incorporada e utilizada nos setores da saúde e equipes multidisciplinares. Objetivo: verificar a aplicabilidade do Questionário de Auto-avaliação do Handicap Auditivo para Idosos, para classificar indivíduos segundo as categorias da Classificação Internacional de Funcionalidade, Incapacidade e Saúde; estabelecer as categorias da Classificação Internacional de Funcionalidade, Incapacidade e Saúde, para indivíduos que apresentem perda auditiva e investigar a prevalência de alterações na funcionalidade em indivíduos com perda auditiva. Método: foi realizado o Hearing Handicap Inventory for the Elderly e posteriormente selecionadas as categorias da Classificação Internacional de Funcionalidade, Incapacidade e Saúde. Resultados: 44,83% apresentaram percepção severa de sua incapacidade. 62,1% apresentaram: perda auditiva moderada que afeta as funções do corpo, as funções mentais, de percepção e auditiva (cod b1560.1), perda auditiva moderada que afeta as funções do corpo, as funções sensoriais, as funções auditivas e a detecção do som (cod b2300.1), alteração qualitativa na estrutura do ouvido interno, neste caso sendo caracterizada como perda auditiva sensorioneural moderada bilateral (cod s2609.173); 62,1% não apresenta dificuldade para situações que envolvam atividades de conversação com a família (cod d3508.0_); 58,6% não apresenta dificuldade nas funções auditivas de discriminação auditiva (cod b2308.0); 69,0% apresenta muita dificuldade para ouvir nas suas atividades de participação (cod d115.4_), não apresenta dificuldade em controlar emoções e impulsos nas interações pessoais complexas (cod d7202.0_), não apresenta dificuldade para frequentar serviços religiosos (cod d9309.0_); 51,7% apresenta grande dificuldade para participar na vida comunitária quando se trata de cerimônias (cod d9102.4_). Conclusão: a CIF apresenta importante aplicabilidade para categorizar indivíduos com perda auditiva; o questionário utilizado é parcialmente aplicável para classificar de forma completa as incapacidades dos sujeitos com perda auditiva
438

Potencial Evocado Auditivo de Longa Latência em crianças usuárias de implante coclear / Long Latency Auditory Evoked Potential in children users of cochlear implants

Figueiredo, Sabrina Suellen Rolim 10 March 2015 (has links)
Made available in DSpace on 2016-04-27T18:12:08Z (GMT). No. of bitstreams: 1 Sabrina Suellen Rolim Figueiredo.pdf: 2435322 bytes, checksum: 78add1dbad501718c6c691e2e9c8845c (MD5) Previous issue date: 2015-03-10 / The use of amplification and implantable devices is an alternative to minimize the effects of sensory deprivation, imposed by hearing loss. The effects of sensory deprivation in the central auditory system have been studied by recording the latencies of Long Latency Auditory Evoked Potential (LLAEP) as a cortical maturation indicator. The assessment of auditory cortical development of the child user of cochlear implant (CI) can provide important data on the conditions of the upper ways, and the effectiveness of the strategy used after the intervention, through the use of hearing aids or CI. OBJECTIVE: To study the LLAEP in children with bilateral sensorineural hearing loss, severe and/or profound cochlear implant users. METHOD: This study is qualitative/quantitative, descriptive, using the LLAEP in children with sensorineural severe and/or profound hearing with cochlear implant. The participants were 8 children using unilateral cochlear implant, age ranging between 3 and 5 years old. Data were collected regarding the etiology, hearing age, chronological age at implantation, mean values of free field audiometry with CI, and the record of LLAEP in the free field as a transducer with the speech stimulus /ba/, in the intensity of 75 dBSPL, with the use of CI. The eye movement was recorded to control the generated artifact. RESULTS: The values of LLAEP latency were statistically analyzed and described according to the study variables. It was possible to identify the component P1 in all volunteers in the study. Regarding the N1 component, 50% of the patients showed responses allowing the registry. None of the participants presented the P2 component. There is a statistically significant correlation founded between the latency value of the N1 component and the time in which the participant had no use of hearing aids, waiting for the diagnosis. CONCLUSION: LLEAP may be useful in routine clinical audiology to monitor the central auditory development in children with cochlear implants. The effects of central auditory deprivation and changes in central auditory processing can be monitored by recording LLAEP and monitoring of other factors that influence the user's IC auditory performance / O uso de dispositivos de amplificação e dispositivos implantáveis é uma alternativa para minimizar os efeitos da privação sensorial, imposta pela deficiência auditiva. Os efeitos da privação sensorial no sistema auditivo central têm sido estudados por meio do registro das latências do Potencial Evocado Auditivo de Longa Latência (PEALL) como um indicador de maturação cortical. A avaliação do desenvolvimento cortical auditivo da criança usuária de Implante Coclear (IC) pode fornecer dados importantes sobre as condições das vias superiores, e a efetividade da estratégia utilizada, após a intervenção, por meio da adaptação de AASI ou de IC. OBJETIVO: Estudar o PEALL em crianças usuárias de Implante Coclear. MÉTODO: O estudo é do tipo quali/quantitativo, descritivo, por meio da realização do PEALL em crianças com deficiência auditiva sensorioneural de grau severo e/ou profundo adaptadas ao Implante Coclear. Participaram da pesquisa 8 crianças usuárias de Implante Coclear unilateral, com idades entre 3 a 5 anos. Foram coletados dados referentes à etiologia, idade auditiva, idade cronológica na ativação, valores médios da audiometria em campo livre com IC, e o registro dos PEALL, com o estímulo de fala /ba/ na intensidade de 75 dBNPS. O registro do movimento ocular foi realizado para melhor controle do artefato gerado. RESULTADOS: Os valores de latência dos PEALL foram analisados estatisticamente e descritos de acordo com as variáveis do estudo. Foi possível identificar o componente P1 em todos os voluntários do estudo. Com relação ao componente N1, metade da amostra apresentou respostas possibilitando o registro. Nenhum dos participantes apresentou o componente P2. Foi encontrada correlação estatisticamente significante entre o valor de latência do componente N1 e o tempo em que o participante ficou sem uso de AASI, aguardando o diagnóstico. CONCLUSÃO: O registro dos PEALL é viável e útil na rotina da clínica fonoaudiológica para o acompanhamento do desenvolvimento auditivo central em crianças com implantes cocleares. Os efeitos da privação auditiva central e as mudanças no processamento auditivo central podem ser monitoradas pelo registro dos PEALL e pelo acompanhamento dos demais fatores que influenciam a performance do usuário de IC
439

Avaliação do handicap em trabalhadores com perda auditiva induzida por ruído / Handicap´s avaliation in workers witn noise-induced hearing loss

Oliveira, Priscila Feliciano de 10 October 2007 (has links)
Made available in DSpace on 2016-04-27T18:12:25Z (GMT). No. of bitstreams: 1 Priscila Feliciano de Oliveira.pdf: 298919 bytes, checksum: d19d00fc10c4a2440c760088e47f3528 (MD5) Previous issue date: 2007-10-10 / Introduction: Continuous exposure to loud sound pressure levels can cause noise-induced hearing loss (NHIL) and consequently affect the quality of life for these subjects. The handicap of hearing loss has a psychological effect characterized by isolation, stress, difficulties with family relationships, anxiety, sleep difficulties, less confidence and depression. Objective: This research shows the handicap of nourishing branch workers, intent juice workers and cement workers with noise induced hearing loss. Methods: An anamnese and a questionnaire of the handicap scale named Hearing Handicap Inventory for Adults (HHIA) were administered to 72 workers. The subjects were 23 to 58 years old and the mean age at which exposed to occupational noise was 14,5 years. Results: In 72 workers, 21 (29,2%) had handicap presence. The led/moderate auto-perception was shown in 10 (13,9%) workers and severe/significant was shown in 11 people (15,3%). In social/situational scale, the main complaints were using less telephone (38,9%), difficulties to hearing/understanding business colleagues (34,7%) and watching TV and listening to the radio (33,3%). In emotional scale 33,3% were irritated, 30,6% were bored of having difficulties in hearing and 27,8% were constrained or felt sad when they were presented to someone new. In audiograms analysis, the most affected frequency was in the range of 3 to 8 kHz, with worse thresholds in 4 kHz. The relationship between hearing loss and handicap presence was not shown. Conclusion: The handicap presence was observed in 29,2% and there did not appear to be a significant statistical difference between handicap and age, time of noise exposure, tinnitus, and hearing loss / Introdução: A exposição continuada a elevados níveis de pressão sonora podem ocasionar uma perda auditiva induzida por ruído (PAIR) e conseqüentemente provocar efeitos na qualidade de vida do indivíduo. O handicap decorrente de uma perda auditiva é uma alteração psicossocial caracterizada por isolamento, estresse, dificuldades nas relações familiares, ansiedade, dificuldade de sono, diminuição da auto-estima e depressão. Objetivo: Este estudo avaliou a auto-percepção do handicap auditivo decorrente de PAIR em trabalhadores do segmento alimentício e da produção de cimento no Estado de Sergipe. Método: A amostra foi composta por 72 trabalhadores na faixa etária de 23 a 58 anos e com tempo médio de exposição a ruído de 14,5 anos. Foram utilizados um protocolo de anamnese e o questionário de auto-percepção de handicap auditivo- Hearing Handicap Inventory for Adults (HHIA). Resultados: Dos 72 trabalhadores, 21 (29,2%) apresentaram presença handicap auditivo. A auto-percepção de grau leve/moderado foi encontrada em 10 (13,9%) sujeitos e de grau severo/significativo em 11 sujeitos (15,3%).Na escala social/situacional, as principais queixas foram utilizar menos o telefone (38,9%), dificuldades para ouvir/entender os colegas de trabalho (34,7%) e para assistir TV e ouvir rádio (33,3%). Na escala emocional 33,3 % ficam irritados, 30,6% ficam chateados por apresentar dificuldades em ouvir e 27,8% ficam constrangidos ou sem jeito quando são apresentados a pessoas estranhas. Na análise dos audiogramas, o maior comprometimento foi na faixa de freqüência de 3 a 8kHz com piores limiares em 4 kHz. Não foi observada relação da perda auditiva com a presença de handicap. Conclusões: A presença de auto-percepção de handicap auditivo foi de 29,2% e não houve diferença estatisticamente significante entre o handicap a as variáveis idade, tempo de exposição ao ruído, zumbido e grau de perda auditiva
440

A exposição a ruído e o handicap auditivo em trabalhadores de uma indústria textil / The noise exposure and the hearing handicap on textile industry employees

Alves, Adriana Soares 11 February 2010 (has links)
Made available in DSpace on 2016-04-27T18:12:43Z (GMT). No. of bitstreams: 1 ADRIANA SOARES ALVES.pdf: 924579 bytes, checksum: 2f204404494bf32fb7678a29fc64cb3e (MD5) Previous issue date: 2010-02-11 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Introduction: Continuous exposition to high levels of sonorant pressure can cause a noise induced hearing loss (NIAL) and consequently provoque negative effects on the individual quality of life. Objective: Analysing the hearing handicap auto-perception on textile industry employees with and without noise induced hearing loss. Method: The transversal type of the epidemiological study sample was constituted by 83 employees, being 54 from the Normal Group and 29 from the NIAL group. The age group varyed from 23 to 62 years old. All the employees had been exposed to an occupational noise above 85dB(A) at least for two years. A brief question protocol and the questionnaire about hearing handicap auto-perception named Hearing Handicap Inventory for Adults (HHIA) have been used. Results: 27.8% of the Normal Group employees presented an audiometric notch in one ear at least. The highest frequency was 6kHz. In the NIAL Group the hearing losses were from 3kHz to 8kHz in the right ear, and from 2kHz to 8kHz in the left ear. 24.1% of the NIAL group presented a light / moderate handicap. The Normal Group employees did not present hearing handicap. There was a statiscally significant association between an auto-reporting hearing loss and being part of the NIAL group.Conclusion: Despite the low rate of handicap in the HHIA, the high occurrence of hearing complaints indicates the importance of the studies about noise effects, independently of the hearing loss presence / Introdução: A exposição continuada a elevados níveis de pressão sonora pode ocasionar uma perda auditiva induzida por ruído (PAIR) e, conseqüentemente, provocar efeitos na qualidade de vida do indivíduo. Objetivo: analisar a auto-percepção do handicap auditivo em trabalhadores de uma indústria têxtil com e sem a presença de perda auditiva induzida por ruído. Método: A amostra do estudo epidemiológico do tipo transversal foi composta por 83 funcionários, sendo 54 do grupo Normal e 29 do grupo PAIR. A faixa etária variou de 23 a 62 anos. Todos os trabalhadores estavam expostos a ruído ocupacional acima de 85 dB(A) há, no mínimo, dois anos. Foram utilizados um breve protocolo de anamnese e o questionário de auto-percepção de handicap auditivo denominado Hearing Handicap Inventory for Adults ( HHIA). Resultados: No Grupo Normal, 27,8% apresentaram entalhe audiométrico em pelo menos uma orelha. A freqüência mais acometido foi 6 kHz. No Grupo PAIR, as perdas auditivas foram entre 3 kHz a 8 kHz na orelha direita e entre 2 kHz e 8 kHz na orelha esquerda. Foi identificado handicap de grau leve/moderado em 24,1% do Grupo PAIR. Os trabalhadores do Grupo Normal não apresentaram handicap auditivo. Houve associação estatisticamente significante entre auto-referir perda auditiva e pertencer ao Grupo PAIR. Conclusão: Apesar do baixo índice de handicap no HHIA, a alta ocorrência de queixas auditivas indica a importância de estudos sobre os efeitos do ruído, independente da presença de perda auditiva

Page generated in 0.0842 seconds