• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 732
  • 339
  • 175
  • 132
  • 31
  • 20
  • 20
  • 20
  • 20
  • 20
  • 19
  • 14
  • 10
  • 9
  • 9
  • Tagged with
  • 1768
  • 297
  • 216
  • 172
  • 148
  • 144
  • 125
  • 114
  • 102
  • 93
  • 93
  • 93
  • 91
  • 87
  • 82
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
811

Efeito do estresse agudo, crônico e ambos combinados na permeabilidade intestinal de ratos

Lauffer, Adriana January 2015 (has links)
Introdução: o estresse psicológico aumenta a permeabilidade intestinal em roedores e humanos, potencialmente levando a inflamação de baixo grau e aos sintomas em distúrbios gastrintestinais funcionais. No entanto, o efeito do estresse agudo combinado ao estresse da vida crônica, que mimetiza potencialmente melhor a situação humana, é desconhecido. Além disso, há poucos dados disponíveis sobre os efeitos do estresse em intestino delgado versus cólon. Métodos: ratos Wistar foram alocados em quatro protocolos de estresse: 1/ controles; 2/ estresse agudo (isolamento e movimentos limitados); 3/ Crowding stress:crônico e 4/ estresse agudo + estresse crônico. Amostras de jejuno e cólon foram colhidas para estudar a permeabilidade em câmaras deUssing, a expressão gênica de moléculas de junção firmes e a densidade de mastócitos. Níveis de corticosterona no plasma foram medidos. Principais resultados:corticosterona plasmática foi avaliada nas três condições de estresse, teve níveis mais altos na condição de estresse combinado. Permeabilidade do jejuno foi aumentada em todas as condições de estresse e correlacionada com os níveis de corticosterona. O aumento da expressão das claudinas 1, 5 e 8, daocludina e da ZO-1 foi detectado no estado de estresse agudo no jejuno. Em contraste, a permeabilidade do cólon foi aumentada no protocolo de estresse combinado, e a expressão de moléculas das junção firmes permaneceu inalterada. O aumento da densidade de mastócitos foi observado no cólon nos ratos submetidos aos estresses crônico e combinado. Conclusão e inferências:os estresses agudo, crônico e combinado influenciam diferentemente a permeabilidade intestinal, a expressão de moléculas de junção firmes e a atividade dos mastócitos, no jejuno e no cólon. Estes resultados fornecem uma visão mais aprofundada dos mecanismos de hiperpermeabilidade intestinal relacionadas ao estresse. / Background: Psychological stress increases intestinal permeability in rodents and humans, potentially leading to low-grade inflammation and symptoms in functional gastrointestinal disorders through disturbances in brain-gut axis. However, the effect of acute stress on the background of Crhonic life stress, potentially better approaching the human situation, is unknown. Moreover, only limited information is available on the effects in small intestine versus colon in animal model. Methods: Wistar rats were allocated to 4 stress protocols: 1/ sham; 2/ acute stress (isolation and limited movement); 3/ Crhonic crowding stress and 4/ acute + Crhonic stress (n = 8 per group). Jejunum and colon were harvested to study permeability in Ussing chambers, gene expression of tight junction molecules and mast cell density. Plasma corticosterone levels were measured. Key Results: Plasma corticosterone was elevated in all three stress conditions, with the highest levels in the combined stress condition. Permeability of the jejunum was increased in all stress conditions and correlated with corticosterone levels. Increased expression of claudin 1, 5 and 8, occludin and ZO-1 was detected in the acute stress condition in the jejunum. In contrast, colonic permeability was increased in the acute on Crhonic stress protocol only and the expression of tight junction molecules was unaltered. Increased mast cell density was observed in the Crhonic and acute on Crhonic stress condition in the colon only. Conclusion and Inferences: Acute, Crhonic and combined stress differentially affect intestinal permeability, expression of tight junction molecules and mast cells in the jejunum and the colon. These findings provide further insight in the mechanisms of stress-related intestinal hyperpermeability and barrier.
812

Potencialização da ação de produtos lipofílicos provenientes de espécies de Hypericum nativas do sul do Brasil / Potentiation of action of lipophilic products from Hypericum species native to south Brazil

Meirelles, Gabriela de Carvalho January 2016 (has links)
Plantas do gênero Hypericum (Hypericaceae) são reconhecidas fontes de moléculas com fins terapêuticos. Para espécies nativas do sul do Brasil, atividades como antifúngica e antinociceptiva já foram relatadas, atribuídas principalmente a compostos extraídos em suas frações lipofílicas como derivados de floroglucinol, benzopiranos e benzofenonas. Neste estudo, o potencial sinérgico entre frações lipofílicas de H. carinatum e o fármaco fluconazol, frente a fungos leveduriformes emergentes, foi avaliado por duas metodologias distintas: checkerboard e isobolograma. Para isolados de Candida krusei e C. famata o efeito da associação foi superior ao do fármaco isolado. Dessa forma, o perfil de suscetibilidade observado sugere que a fração esteja auxiliando a ação do fármaco. Ainda abordando o potencial terapêutico de espécies de Hypericum, a investigação da atividade antinociceptiva (via oral) do benzopirano HP1 de H. polyanthemum, quando incorporado em nanoemulsões, foi avaliada. Os resultados demonstraram que HP1 pode ser adequadamente incorporado em nanoemulsões, dada sua solubilidade no núcleo oleoso. Em relação ao efeito antinociceptivo, nanoemulsões contendo HP1 demonstraram o mesmo efeito do composto livre, em magnitude, porém em dose inferior. A redução da dose ativa sugere que uma melhor solubilização do composto possa ter ocorrido quando o mesmo está inserido em nanoemulsões. Nesse contexto, estudos de permeabilidade intestinal ex vivo (Ussing chambers) de HP1, na sua forma livre e incorporado em nanoemulsões, foram realizados. Os resultados demonstraram que a permeabilidade intestinal do benzopirano HP1, quando incorporado em nanoemulsões, foi cerca de 4 vezes maior em relação a forma livre. Além disso, experimentos de lipólise in vitro mostraram que enzimas presentes no trato gastrointestinal são hábeis em hidrolisar nanoemulsões a espécies coloidais, mais solúveis e facilmente absorvíveis pelas células intestinais. Ainda, a permeabilidade intestinal do benzopirano HP1, na sua forma livre, no sentido absortivo foi maior que no sentido secretório indicando que transportadores ativos estão, ao menos em parte, auxiliando a absorção deste composto pelas células intestinais. Dessa forma, com vistas a elucidar o provável transportador ativo de HP1, dada a semelhança estrutural deste benzopirano com moléculas canabinoides e a relação existente entre os sistemas opioide e canabinoide, a influência deste último na absorção de HP1 foi investigada. Os resultados demonstraram que o benzopirano HP1 pode estar relacionado ao sistema canabinoide, mas a natureza dessa ligação, seja de transporte, agonismo/antagonismo ou físico-química, não foi possível de ser elucidada. Os resultados obtidos nesta tese são relevantes à medida que espécies de fungos leveduriformes emergentes se mostram cada vez mais resistentes aos fármacos comumente utilizados. Além disso, a importância destes resultados se dá pela viabilidade de incorporação do benzopirano HP1 em nanoemulsões e a capacidade desses sistemas em reduzir a dose ativa no benzopirano HP1 por uma maior solubilização do composto e assim, melhor absorção. Dessa maneira, os resultados deste trabalho representam o alto potencial biológico de espécies de Hypericum e abrem possibilidade para mais estudos utilizando estas plantas. / Plants from genus Hypericum (Hypericaceae) are recognized as a source of therapeutical agents. To south Brazil species, acitivities like antifungal and antinociceptive had already been demonstrated, attributed mainly to compounds from lipophilic fractions as phloroglucinol derivatives, benzophenones and benzopyrans. In this study, antifungal potential of lipophilic fractions of H. carinatum and fluconazole against emerging yeasts was evaluated by two methodologies for multiple dose-response analyzes: checkerboard and isobologram. To Candida krusei and C. famata isolates the effect of association was higher than the effect of fluconazole alone. Thus, the susceptibility profile observed for these species suggests that, somehow, the fractions are facilitating the action of drug. Still on therapeutical potential of Hypericum species, the antinociceptive study of a benzopyran (HP1) isolated from H. polyanthemum, incorporate in nanoemulsions, was evaluated. The results demonstrated that HP1 could be incorporated in a nanoemulsion system, given the high solubility in the oil core. Regarding the antinociceptive effect, HP1 loaded in nanoemulsions showed the same effect of free form, in magnitude, at lower doses. These results suggest a better solubilization of HP1 when loaded in nanoemulsions, and, thus, better absorption by organism. In this context, ex vivo intestinal permeability studies (Ussing chambers) of HP1 free form and loaded in nanoemulsions were performed. The results showed that the intestinal permeability of HP1 loaded in nanoemulsions were about 4 times higher than HP1 free form. Besides, the intestinal permeability of HP1 free form in absorptive direction was higher than secretory direction indicating that active transporters are, at least in part, involved in HP1 intestinal absorption. Thus, in order to elucidate the probable active transporter of HP1 and since its structure looks like a cannabinoid molecule and there is a relation between the opioid and cannabinoid pathways, the influence of intestinal cannabinoid system in HP1 absorption was investigated. The results indicated that the benzopyran HP1 may be related to cannabinoid system, but the nature of this interaction: transport, agonism/antagonism or physico-chemical is still unknown. The outcomes obtained are relevant since the resistance of emerging yeast species to available drugs, used for a variety of fungal infections, is increasing. The importance of these findings lies also in the feasibility of incorporating HP1 into nanoemulsions, and the capacity of these systems in reduce the antinociceptive active doses, by higher solubilization, and thus, absorption. Then, together the results represent the high biological potential of Hypericum species and open new possibilities to further studies with these plants.
813

Avaliação da resistência de união à tração e espessura de camada híbrida : influência de sistemas adesivos e condições de substrato dentinário

Susin, Alexandre Henrique [UNESP] 08 October 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:27Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-10-08Bitstream added on 2014-06-13T19:01:43Z : No. of bitstreams: 1 susin_ah_dr_arafo.pdf: 3155550 bytes, checksum: 3c18f1511d8950d04d4fb3ead12080d0 (MD5) / O objetivo deste trabalho foi realizar, in vitro, avaliação da resistência de união à tração (RUT) e espessura de camada híbrida (ECH), em diferentes condições de substrato dentinário (úmido, S1; desidratado, S2 e reumedecido, S3), proporcionado pelos sistemas adesivos de 4ª geração, Scotchbond Multi Uso (SBMU) - 3M ESPE; Single Bond (SB) - 3M ESPE; Prime & Bond 2.1 (P&B2.1) - Dentsply e One Coat Bond (OCB) - Coltène-Whaledent, e os sistemas adesivos de 5ª geração (autocondicionantes), Clearfil SE Bond (CSEB) - Kuraray e One Up Bond F (OUBF) - Tokuyama. Foram utilizados 180 dentes seccionados na altura do 1/3 médio da coroa, originando duas partes cada um: remanescente dental (utilizado no teste de resistência de união à tração) e fragmento oclusal (utilizado na mensuração de camada híbrida). Para cada um dos 18 grupos foram realizadas 10 repetições em cada um dos dois testes, perfazendo um total de 360 amostras. O teste de RUT, foi realizado na Máquina de Ensaios Mecânicos MTS-810, em velocidade de 2 mm / min., e a ECH, foi mensurada à partir de fotografias obtidas em microscopia eletrônica de varredura (Microscópio Eletrônico JSM 330 A), com o software Image Tool 2.00. No teste de RUT, o desempenho dos sistemas adesivos foi melhor em S1 e, dentre eles, o CSEB foi o que apresentou a maior média, 23,01 MPa, enquanto que a menor, foi apresentada pelo OUBF, 15,69 MPa. Os sistemas adesivos de 4ª geração apresentaram médias intermediárias, às quais não foi possível encontrar diferenças estatisticamente significantes. (SBMU, 18,71 MPa; SB, 19,43 MPa; P&B2.1, 17,45 MPa e OCB, 19,92 MPa). As menores médias de RUT dos sistemas adesivos de 4ª geração, foram constatadas em S2, apresentando a menor média para o SB, 6,64 MPa, enquanto que os sistemas autocondicionantes, apresentaram menores variações de RUT entre os... . / The aim of this work was to perform the evaluation of the tensile bond strength (TBS) and the thickness of the hybrid layer (THL), in different conditions of dentinal substrate (moist, S1; dehydrated, S2 and remoistened, S3), provided by the fourth generation adhesive systems, Scotchbond Multi Uso (SBMU) - 3M ESPE; Single Bond (SB) - 3M ESPE; Prime & Bond 2.1 (P&B2.1) - Dentsply and One Coat Bond (OCB) - Coltène-Whaledent, and the fifth generation adhesive systems (self-etching), Clearfil SE Bond (CSEB) - Kuraray and One Up Bond F - Tokuyama. One hundred and eighty teeth bisected in the 1/3 crown mean level were used, originating two parts each: dental remnant (used in the tensile bond strength testing) and occlusal fragment (used in the hybrid layer measurement). For each of the 18 groups, 10 repetitions were performed for both tests, in a total of 360 samples. The TBS test was performed in a Mechanic Testing Machine MTS-810, in speed 2 mm/ min, and the THL was measured from photographs obtained in scanning electron microscopy (Electron Microscope JSM 330 A), using a software Image Tool 2.00. During the TBS test, the performance of the adhesive systems was better in S1 and, among themselves, CSEB presented the higher average, 23,01 MPa, while the lower average was presented by OUBF, 15,69 MPa. The fourth generation adhesive systems presented intermediate averages, those which did not revealed statistically significant differences. (SBMU, 18,71 MPa; SB, 19,43 MPa; P&B2,1, 17,45 MPa and OCB, 19,92 MPa). The lower averages of the fourth generation adhesive systems in TBS were verified in S2, presenting the lower average for SB, 6,64 MPa, while the self-etching systems presented lower TBS variations among the different substrates. In the THL results, lower variability was verified among the average results obtained, being the higher average presented by SBMU, 4,80 æm... (Complete abstract, click electronic address below).
814

Desenvolvimento de cimento ósseo de fosfato de cálcio como suporte para o crescimento de tecidos

Machado, Jeferson Luis de Moraes January 2007 (has links)
O crescimento de células em arcabouços tridimensionais porosos tem se tornado progressivamente ativo na engenharia de tecidos. Os arcabouços guiam o crescimento celular, sintetizam uma matriz extracelular e outras moléculas biológicas, e facilitam a formação de tecidos e órgãos funcionais. Um cimento deste tipo pode ser preparado misturando um sal de fosfato de cálcio com uma solução aquosa para que se forme uma pasta que possa reagir à temperatura corporal dando lugar a um precipitado que contenha hidroxiapatita (Ca10(PO4)6(OH)2). A similaridade química e morfológica entre este biomaterial e a parte mineral dos tecidos ósseos permite a osteocondução, sendo o cimento substituído por tecido ósseo novo com o tempo e com a vantagem de não desencadear processos inflamatórios e de corpo estranho, com eventual expulsão do material implantado. O objetivo do presente trabalho foi a obtenção e caracterização de suportes tridimensionais para a engenharia de tecido, com o uso de matérias-primas nacionais, por meio da utilização de microesferas de parafina como corpos geradores de poros. As microesferas foram produzidas por suspensão em solução aquosa de poli (álcool vinílico) (PVA) e sulfato de sódio (Na2SO4). Foram analisadas as fases presentes no cimento sintetizado e após a reação de cura do mesmo, a variação do tamanho de partícula e da resistência mecânica com o tempo de moagem. Foi analisada a porosidade dos suportes e a forma de extração da parafina daqueles que a utilizaram na sua formação. O tamanho de poro dos suportes gerados com a variação da quantidade de fase líquida ficou aquém do tamanho considerado ideal para o crescimento de tecido ósseo. A porosidade dos arcabouços fabricados com esferas de parafina foi observada por microscopia eletrônica de varredura (MEV), e seu comportamento foi analisado a partir de ensaios in vitro em solução SBF (simulated body fluid) e em cultura de células. A utilização de esferas de parafina permitiu a formação de poros com tamanho tal que possibilitam potencialmente o crescimento tecidual e celular. / The growth of cells in three-dimensional porous scaffolds has been extensively studied for use in tissue engineering. They guide grow of cells, synthesize extra cellular matrix and other biological molecules, and facilitate the formation of functional tissues and organs. Bone cements has been developed for biomedical applications for a decade approximately. This kind of cement can be prepared mixing a calcium phosphate salt with aqueous solution forming a paste that can react at body temperature generating a hydroxyapatite precipitated (Ca10(PO4)6(OH)2). The chemical and morphological similarity between the cement composition and the mineral part of the bones allows osteoconduction in the tissue with replacement of cement by new bone formed with the advantage to not unchain inflammatory processes and of strange body. The objective of this work was the use of the α-TCP cement for making these scaffolds, through the variation of the amount of liquid phase in the cement and of the use of paraffin spheres as pore source. These spheres were produced by suspension in water solution of poly (vinyl alcohol) and sodium sulphate (Na2SO4). The phases had been analyzed in the synthesized cement and after the reaction of cure of cement, beyond variation of the particle size and the resistance mechanics with the milling time. It was analyzed the porosity of the scaffolds and the extraction of the paraffin in that supports. The pore size of the supports generated with the variation of the amount of liquid phase was on this side of the size considered ideal for the bone tissue growth. The porosity of scaffolds manufactured with paraffin spheres was observed by Scanning Electron Microscopy (SEM), and its behavior was analyzed from test in vitro in SBF solution (simulated body fluid). The use of paraffin spheres allowed the formation of pores size able to permit tissue growth.
815

Crystalline and amorphous metallic membranes for hydrogen separation

January 2015 (has links)
abstract: In the United States, 95% of the industrially produced hydrogen is from natural gas reforming. Membrane-based techniques offer great potential for energy efficient hydrogen separations. Pd77Ag23 is the bench-mark metallic membrane material for hydrogen separation at high temperatures. However, the high cost of palladium limits widespread application. Amorphous metals with lower cost elements are one alternative to replace palladium-based membranes. The overall aim of this thesis is to investigate the potential of binary and ternary amorphous metallic membranes for hydrogen separation. First, as a benchmark, the influence of surface state of Pd77Ag23 crystalline metallic membranes on the hydrogen permeability was investigated. Second, the hydrogen permeability, thermal stability and mechanical properties of Cu-Zr and Ni60Nb35M5 (M=Sn, Ti and Zr) amorphous metallic membranes was evaluated. Different heat treatments were applied to commercial Pd77Ag23 membranes to promote surface segregation. X-ray photoelectron spectroscopy (XPS) analysis indicates that the membrane surface composition changed after heat treatment. The surface area of all membranes increased after heat treatment. The higher the surface Pd/(Pd+Ag) ratio, the higher the hydrogen permeability. Surface carbon removal and surface area increase cannot explain the observed permeability differences. Previous computational modeling predicted that Cu54Zr46 would have high hydrogen permeability. Amorphous metallic Cu-Zr (Zr=37, 54, 60 at. %) membranes were synthesized and investigated. The surface oxides may result in the lower experimental hydrogen permeability lower than that predicted by the simulations. The permeability decrease indicates that the Cu-Zr alloys crystallized in less than two hours during the test (performed at 300 °C) at temperatures below the glass transition temperature. This original experimental results show that thermal stability of amorphous metallic membranes is critical for hydrogen separation applications. The hydrogen permeability of Ni60Nb35M5 (M=Sn, Ti and Zr) amorphous metallic membranes was investigated. Nanoindentation shows that the Young’s modulus and hardness increased after hydrogen permeability test. The structure is maintained amorphous after 24 hours of hydrogen permeability testing at 400°C. The maximum hydrogen permeability of three alloys is 10-10 mol m-1 s-1 Pa-0.5. Though these alloys exhibited a slight hydrogen permeability decreased during the test, the amorphous metallic membranes were thermally stable and did not crystalize. / Dissertation/Thesis / Doctoral Dissertation Materials Science and Engineering 2015
816

Elaboration et caractérisation de matériaux d'étanchéité à base de vermiculite / Preparation and characterization of sealing materials based on vermiculite

Nguyen, Ngoc An 20 January 2012 (has links)
Les travaux de recherche portent sur un procédé d’élaboration par pressage de joints en vermiculite et sur l’étude de la structure multiéchelle et les propriétés d’étanchéité des joints. La vermiculite a été traitée aux ultrasons pour obtenir des poudres. Des joints ont été élaborés à partir des poudres de vermiculite. Les pores interparticulaires du joint sont connectés et orientés préférentiellement d’après les observations par MEB. Leur dimension mesurée par porosimétrie mercure diminue avec l’augmentation de pression.Les propriétés d’étanchéité ont été étudiées aux températures inférieures à 800°C en mesurant les taux de fuites à l’hélium, ainsi que les taux d’écrasement et de décompression. La fuite comprend deux composantes : la fuite de contact déterminée par l’interface entre les joints et la bride, et la fuite de perméabilité liée à la porosité des joints. / Vermiculite gasket materials were obtained from powders obtained by sonication of vermiculite. The materials were formed of oriented stacked vermiculites platelets. The porous structure characterized by mercury porosimetry, SEM observations, was described. Vermiculite gaskets obtained by pressing powders, were studied for their sealing properties: leak rate and elastic resiliency.
817

Avaliação da resistência de união à tração e espessura de camada híbrida : influência de sistemas adesivos e condições de substrato dentinário /

Susin, Alexandre Henrique January 2002 (has links)
Orientador : Osmir Batista de Oliveira Júnior / Banca: José Roberto Cury Saad / Banca: Maria Salete Machado Cândido / Banca: Edson Alves de Campos / Banca: Denise Pedrini / Resumo: O objetivo deste trabalho foi realizar, in vitro, avaliação da resistência de união à tração (RUT) e espessura de camada híbrida (ECH), em diferentes condições de substrato dentinário (úmido, S1; desidratado, S2 e reumedecido, S3), proporcionado pelos sistemas adesivos de 4ª geração, Scotchbond Multi Uso (SBMU) - 3M ESPE; Single Bond (SB) - 3M ESPE; Prime & Bond 2.1 (P&B2.1) - Dentsply e One Coat Bond (OCB) - Coltène-Whaledent, e os sistemas adesivos de 5ª geração (autocondicionantes), Clearfil SE Bond (CSEB) - Kuraray e One Up Bond F (OUBF) - Tokuyama. Foram utilizados 180 dentes seccionados na altura do 1/3 médio da coroa, originando duas partes cada um: remanescente dental (utilizado no teste de resistência de união à tração) e fragmento oclusal (utilizado na mensuração de camada híbrida). Para cada um dos 18 grupos foram realizadas 10 repetições em cada um dos dois testes, perfazendo um total de 360 amostras. O teste de RUT, foi realizado na Máquina de Ensaios Mecânicos MTS-810, em velocidade de 2 mm / min., e a ECH, foi mensurada à partir de fotografias obtidas em microscopia eletrônica de varredura (Microscópio Eletrônico JSM 330 A), com o software Image Tool 2.00. No teste de RUT, o desempenho dos sistemas adesivos foi melhor em S1 e, dentre eles, o CSEB foi o que apresentou a maior média, 23,01 MPa, enquanto que a menor, foi apresentada pelo OUBF, 15,69 MPa. Os sistemas adesivos de 4ª geração apresentaram médias intermediárias, às quais não foi possível encontrar diferenças estatisticamente significantes. (SBMU, 18,71 MPa; SB, 19,43 MPa; P&B2.1, 17,45 MPa e OCB, 19,92 MPa). As menores médias de RUT dos sistemas adesivos de 4ª geração, foram constatadas em S2, apresentando a menor média para o SB, 6,64 MPa, enquanto que os sistemas autocondicionantes, apresentaram menores variações de RUT entre os... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The aim of this work was to perform the evaluation of the tensile bond strength (TBS) and the thickness of the hybrid layer (THL), in different conditions of dentinal substrate (moist, S1; dehydrated, S2 and remoistened, S3), provided by the fourth generation adhesive systems, Scotchbond Multi Uso (SBMU) - 3M ESPE; Single Bond (SB) - 3M ESPE; Prime & Bond 2.1 (P&B2.1) - Dentsply and One Coat Bond (OCB) - Coltène-Whaledent, and the fifth generation adhesive systems (self-etching), Clearfil SE Bond (CSEB) - Kuraray and One Up Bond F - Tokuyama. One hundred and eighty teeth bisected in the 1/3 crown mean level were used, originating two parts each: dental remnant (used in the tensile bond strength testing) and occlusal fragment (used in the hybrid layer measurement). For each of the 18 groups, 10 repetitions were performed for both tests, in a total of 360 samples. The TBS test was performed in a Mechanic Testing Machine MTS-810, in speed 2 mm/ min, and the THL was measured from photographs obtained in scanning electron microscopy (Electron Microscope JSM 330 A), using a software Image Tool 2.00. During the TBS test, the performance of the adhesive systems was better in S1 and, among themselves, CSEB presented the higher average, 23,01 MPa, while the lower average was presented by OUBF, 15,69 MPa. The fourth generation adhesive systems presented intermediate averages, those which did not revealed statistically significant differences. (SBMU, 18,71 MPa; SB, 19,43 MPa; P&B2,1, 17,45 MPa and OCB, 19,92 MPa). The lower averages of the fourth generation adhesive systems in TBS were verified in S2, presenting the lower average for SB, 6,64 MPa, while the self-etching systems presented lower TBS variations among the different substrates. In the THL results, lower variability was verified among the average results obtained, being the higher average presented by SBMU, 4,80 æm... (Complete abstract, click electronic address below). / Doutor
818

Estudo preliminar de concretos permeáveis como revestimento de pavimentos para áreas de veículos leves. / Preliminary study on pervious concrete as the surface layer for light traffic areas.

Rafael Batezini 23 November 2012 (has links)
Esta pesquisa teve por finalidade estudar concretos permeáveis para uso como camada de revestimento de pavimentos em áreas de veículos leves, por meio da realização de ensaios laboratoriais de caracterização mecânica e hidráulica para três diferentes misturas com variação do diâmetro máximo de agregados graúdos. Além disso, o estudo procurou interpretar o comportamento desse material quando solicitado por cargas de veículos, a partir de análises numéricas utilizando o software EverFE para análise de placas de concreto por elementos finitos. A caracterização mecânica foi realizada com base em ensaios de resistência à tração na flexão, tração indireta por compressão diametral, compressão, módulo de elasticidade estático e módulo de elasticidade dinâmico por equipamento ultrassônico. Para determinação da condutividade hidráulica foi utilizado um permeâmetro de carga constante. As análises mecanicistas envolveram estudos de placas de concreto permeável solicitadas por um eixo simples de rodas duplas com carga de 80 kN e por um eixo simples de roda simples com carga de 22 kN, simulando, nesse caso, um veículo utilitário leve. O material estudado apresentou para um índice de vazios de aproximadamente 0,25, valores de condutividade hidráulica na ordem de 0,14 cm/s, aproximadamente, caracterizando um material com boa drenabilidade. Com relação às características mecânicas, apresentou resistência à tração na flexão de aproximadamente 2,1 MPa e módulo de elasticidade estático na ordem de 15.000 MPa, se aproximando da metade dos valores normalmente observados em concretos convencionais de uso corrente na pavimentação. Por meio da realização das análises mecanicistas, foi possível avaliar que o material estudado apresenta resistência suficiente para ser utilizado como revestimento de pavimentos para áreas de veículos leves. / The main goal of this research was to study the pervious concrete material as the surface layer for light traffic pavement by carrying out a laboratorial analysis in order to better understand the mechanical and hydraulic behavior of three different coarse aggregate gradation mixtures. Besides that, it was applied a Finite Element Analysis in order to identify the pervious concrete behavior when loaded by different vehicle loads by using the EverFE Software The mechanical characterization was developed by evaluating the tests results of flexural strength, split tensile strength, compressive strength, Youngs Modulus and the non-destructive ultrasonic test. The hydraulic conductivity was measured using a constant head permeameter. In order to carry out the mechanistic analysis, it was considered a pervious concrete slab loaded by both an 80 kN dual wheel axle, and, to simulate a light vehicle, a 22 kN single wheel axle. The studied material has shown, considering the void ratio of 0,25, values of hydraulic conductivity around 0,14 cm/s, characterizing a material with good drenability characteristics. Besides that, it presented a flexural strength of 2,1 MPa and Youngs Modulus of 15.000 MPa, reaching the half of the values commonly used in regular concretes for pavements. By using the mechanistic analysis, it was possible to assess that this specific studied pervious concrete has enough strength to be used as the surface layer of pavements loaded by lightweight vehicles.
819

Influência dos tratamentos dessensibilizantes associados ao laser de diodo na permeabilidade dentinária / Influence of desensitizing treatments associated with diode laser on dentin permeability.

Júlia Olien Sanches 10 January 2013 (has links)
Objetivo: Este estudo avaliou o efeito dos agentes dessensibilizantes associados ou não ao laser de diodo na permeabilidade dentinária e na morfologia da superfície. Materiais e Métodos: Para este estudo, 104 espécimes de dentina radicular bovina foram divididos aleatoriamente em 4 grupos e 2 subgrupos (n=13): G1A= nenhum tratamento (controle), G1B= laser de diodo, G2A= Oxagel, G2B= laser de diodo + Oxagel, G3A= Mi Paste, G3B= laser de diodo + Mi Paste, G4A= Sensitive Pró-Alívio dessensibilizante, G4B= laser de diodo + Sensitive Pró-Alívio dessensibilizante. Para análise da permeabilidade, 10 espécimes de cada grupo foram imersos em ácido clorídrico a 1% durante 20 segundos, 3 vezes, com intervalo de 2 horas entre as imersões, para exposição dos túbulos dentinários. A aplicação dos agentes dessensibilizantes foi feita de acordo com as instruções do fabricante e a irradiação com o laser de diodo foi feita no modo contato, comprimento de onda de 970 nm +/- 10 nm, potência máxima de 7 W CW, frequência de 10 Hz, durante 25 segundos. Em seguida, os espécimes foram submetidos à coloração histoquímica e seccionados para serem analisados quanto à permeabilidade por meio de microscopia óptica (MO). A permeabilidade dentinária foi dada pela porcentagem de penetração do corante em relação à área total do espécime seccionado. Os espécimes remanescentes (n = 3) foram utilizados para análise microscópica da superfície que foi dividida em duas áreas (controle e tratada). A exposição dos túbulos dentinários e a aplicação dos tratamentos foram realizadas da forma já descrita e, na sequência, os espécimes foram avaliados em microscopia eletrônica de varredura (MEV). Os valores obtidos de permeabilidade foram analisados através da ANOVA. Resultados: Nenhuma diferença estatística significante foi observada entre os tratamentos. Na microscopia eletrônica de varredura, foi observada uma ligeira diferença entre a área tratada e a área controle, exceto no grupo 4B. Comparando os grupos A e B (sem e associado ao laser, respectivamente), nenhuma mudança significativa foi notada na superfície dentinária. Conclusão: A aplicação dos agentes dessensibilizantes associados ou não ao laser diodo não influenciou na permeabilidade dentinária radicular e na morfologia da superfície dentinária. / Objective: This study evaluated the effect of desensitizing agents associated or not with laser diode on dentin permeability and surface morphology. Materials and Methods: For this study, 104 bovine root dentin specimens were randomly divided into 4 groups and 2 subgroups (n = 13): G1A = no treatment (control), G1B= diode laser, G2A= Oxagel, G2B= diode laser + Oxagel, G3A= Mi Paste, G3B= diode laser + Mi Paste, G4A= Sensitive Pro-Relief desensitizing, G4B= diode laser + Sensitive Pro-Relief desensitizing. For permeability analysis , 10 specimens were immersed in 1% hydrochloric acid for 20 seconds, three times, with an interval of 2 hours between them, to expose the dentinal tubules. The application of desensitizing agents was performed according to the manufacturers instructions and the irradiation with the laser diode was made on contact mode, wavelength of 970 nm +/- 10 nm, maximum output 7 W CW, 10 Hz, for 25 seconds. After that, the specimens were imaged in an optical microscope (OM) and permeability was measured in the digitized images as the percentage of cooper ions penetration over the total area. The remaining specimens (n = 3) were used for surface microscopic analysis and they were divided in two areas (control and treated). The dentinal tubules exposure and the treatments application were performed as previously described and then analysed in scanning electron microscopy (SEM). The permeability values were analyzed using ANOVA. Results: No statistical significant difference among the treatments was observed. For scanning electron microscopy, there was a slight difference between the treated and control area, except for group 4B. Comparing groups A and B (without and associated with laser, respectively), no significant change was verified on the dentin surface. Conclusion: The application of desensitizing agents associated or not with diode laser did not affect the root dentin permeability and the dentin surface morphology.
820

Atividade antibacteriana de sistemas adesivos dentinários autocondicionantes sobre bactérias cariogênicas

Gondim, Juliana Oliveira [UNESP] 30 November 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:47Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-11-30Bitstream added on 2014-06-13T19:56:38Z : No. of bitstreams: 1 gondim_jo_me_arafo.pdf: 487270 bytes, checksum: 789b8f434824d723680740b007e8975b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A incorporação de agentes antibacterianos aos sistemas adesivos dentinários autocondicionantes tem sido proposta com o intuito de eliminar bactérias residuais presentes na dentina, prevenindo, assim, a recorrência de cárie. O presente trabalho teve como objetivo avaliar a atividade antibacteriana dos sistemas adesivos dentinários autocondicionantes: Clearfil Protect Bond (CPB), Clearfil SE Bond (CSEB), Xeno III (XIII) e Clearfil Tri-S Bond (C3SB), com e sem fotoativação, sobre bactérias cariogênicas, bem como a influência da dentina humana na atividade antibacteriana destes sistemas adesivos, utilizando o método de difusão em ágar. A solução de digluconato de clorexidina a 0,2% foi utilizada como controle positivo. O componente adesivo do CPB e do CSEB, o líquido A do XIII e o C3SB não apresentaram atividade antibacteriana quando aplicados sobre discos de papel. O conjunto primer e adesivo do CPB não fotoativado promoveu a maior inibição contra S. mutans (p<0,05), enquanto que com a fotoativação, não houve diferença entre esses componentes juntos e o primer isoladamente. Para o L. acidophillus, o primer do CPB apresentou a maior atividade antibacteriana nas duas condições de fotoativação (p<0,05). Quando os materiais foram aplicados sobre discos de dentina, somente a CHX promoveu efeito inibitório, o qual foi de menor intensidade do que quando aplicada sobre discos de papel (p<0,05). A CHX apresentou maior atividade antibacteriana sobre S. mutans quando comparado com L. acidophillus (p<0,05). Pode-se observar que a fotoativação reduziu significantemente a 18 atividade antibacteriana dos sistemas adesivos autocondicionantes, que a presença do MDPB no sistema adesivo dentinário é importante para a atividade antibacteriana sobre bactérias cariogênicas, e que a dentina atua como barreira de proteção eliminando ou reduzindo a ação antibacteriana de materiais odontológicos. / The incorporation of antibacterial agents in self-etching dentin bonding systems has been introduced in attempts to eliminate dentin residual bacteria, preventing secondary caries. Therefore, the aim of this study was to evaluate the antibacterial activity of cured and uncured self-etching dentin bonding systems Clearfil Protect Bond (CPB), Clearfil SE Bond (CSEB), Xeno III (XIII) and Clearfil Tri-S Bond (C3SB), against S. mutans and L. acidophillus, by the agar disc-diffusion test, as well as to evaluate the influence of human dentin on their antibacterial activity. A 0.2% aqueous solution of chlorhexidine (CHX) was used as a positive control. CPB and CSEB bond component, liquid A of Xeno III and C3SB did not show any antibacterial activity when applied onto paper discs. The primer and bond set of uncured CPB presented the strongest inhibitory activity against S. mutans (p<0.05), however after light-activation, no difference was observed between these components together and when primer was applied individually. Independently of light-activation conditions, CPB primer showed the strongest antibacterial activity against L. acidophillus (p>0.05). When the materials were applied onto dentin discs, only CHX presented inhibitory activity, which was less intense than when it was applied onto paper discs (p<0.05). CHX showed stronger antibacterial activity against S. mutans than against L. acidophillus (p<0.05). In conclusion, light-activation significantly reduced the antibacterial activity, the presence of MDPB in adhesive systems is important to the inhibitory effect against cariogênico 20 bacteria, and the dentin acted as a protection barrier reducing or inhibiting the antibacterial activity of dental materials.

Page generated in 0.1069 seconds