• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 7
  • 5
  • Tagged with
  • 24
  • 24
  • 24
  • 15
  • 12
  • 11
  • 10
  • 10
  • 9
  • 8
  • 8
  • 8
  • 8
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Aplicação do algoritmo genético de Chu-Beasley especializado no ajuste dos parâmetros dos controladores suplementares e dispositivo FACTS IPFC /

Fortes, Elenilson de Vargas January 2016 (has links)
Orientador: Percival Bueno de Araujo / Resumo: Este trabalho apresenta o Algoritmo Genético de Chu-Beasley Especializado para realizar o ajuste coordenado dos parâmetros de controladores Proporcional-Integral e suplementares de amortecimento (Estabilizadores de Sistemas de Potência e Interline Power Flow Controller - Power Oscillation Damping) em sistemas elétricos de potência multimáquinas. O objetivo principal deste trabalho é inserir amortecimento adicional às oscilações eletromecânicas de baixa frequência classificadas como local e interárea. Para representar o sistema, é utilizado o Modelo de Sensibilidade de Corrente. Desse modo, todos os seus dispositivos e componentes foram modelados por injeção de corrente e, portanto, um novo modelo de injeção de corrente para o Interline Power Flow Controller é apresentado. Três sistemas teste foram utilizados nas simulações realizadas neste trabalho, sendo: Simétrico de Duas Áreas, New England e o Sul Brasileiro Reduzido. O desempenho da metodologia proposta (Algoritmo Genético de Chu-Beasley Especializado), no que concerne ao ajuste dos parâmetros dos controladores, foi comparado a outros dois algoritmos bastantes difundidos na literatura: Particle Swarm Optimization e o Algoritmo Genético com Elitismo. Os resultados demonstraram que o algoritmo Genético de Chu-Beasley Especializado foi mais eficiente que as demais técnicas apresentadas, obtendo soluções robustas quando variações de cargas foram consideradas, sendo, portanto, credenciado como ferramenta no estudo da análise d... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
12

Analysis Of SubSynchronous Resonance With Voltage Source Converter Based FACTS And HVDC Controllers

Nagesh Prabhu, * 09 1900 (has links) (PDF)
No description available.
13

Investigation of the application of UPFC controllers for weak bus systems subjected to fault conditions : an investigation of the behaviour of a UPFC controller : the voltage stability and power transfer capability of the network and the effect of the position of unsymmetrical fault conditions

Jalboub, Mohamed January 2012 (has links)
In order to identify the weakest bus in a power system so that the Unified Power Flow Controller could be connected, an investigation of static and dynamic voltage stability is presented. Two stability indices, static and dynamic, have been proposed in the thesis. Multi-Input Multi-Output (MIMO) analysis has been used for the dynamic stability analysis. Results based on the Western System Coordinate Council (WSCC) 3-machine, 9-bus test system and IEEE 14 bus Reliability Test System (RTS) shows that these indices detect with the degree of accuracy the weakest bus, the weakest line and the voltage stability margin in the test system before suffering from voltage collapse. Recently, Flexible Alternating Current Transmission systems (FACTs) have become significant due to the need to strengthen existing power systems. The UPFC has been identified in literature as the most comprehensive and complex FACTs equipment that has emerged for the control and optimization of power flow in AC transmission systems. Significant research has been done on the UPFC. However, the extent of UPFC capability, connected to the weakest bus in maintaining the power flows under fault conditions, not only in the line where it is installed, but also in adjacent parallel lines, remains to be studied. In the literature, it has normally been assumed the UPFC is disconnected during a fault period. In this investigation it has been shown that fault conditions can affect the UPFC significantly, even if it occurred on far buses of the power system. This forms the main contribution presented in this thesis. The impact of UPFC in minimizing the disturbances in voltages, currents and power flows under fault conditions are investigated. The WSCC 3-machine, 9-bus test system is used to investigate the effect of an unsymmetrical fault type and position on the operation of UPFC controller in accordance to the G59 protection, stability and regulation. Results show that it is necessary to disconnect the UPFC controller from the power system during unsymmetrical fault conditions.
14

Control of Dynamically Assisted Phase-shifting Transformers

Johansson, Nicklas January 2008 (has links)
<p>In this thesis, controllers for power oscillation damping, transient stability improvement and power flow control by means of a Controlled Series Compensator (CSC) and and a Dynamic Power Flow Controller (DPFC) are proposed. These devices belong to the group of power system components referred to as Flexible AC Transmission System (FACTS) devices. The developed controllers use only quantities measured locally at the FACTS device as inputs, thereby avoiding the risk of interrupted communications associated with the use of remote signals for control.</p><p>For power systems with one dominating, poorly damped inter-area power oscillation mode, it is shown that a simple generic system model can be used as a basis for damping- and power flow control design. The model for control of CSC includes two synchronous machine models representing the two grid areas participating in the oscillation and three reactance variables, representing the interconnecting transmission lines and the FACTS device. The model for control of DPFC is of the same type but it also includes the phase shift of the internal phase-shifting transformer of the DPFC.</p><p>The key parameters of the generic grid models are adaptively set during the controller operation by estimation from the step responses in the FACTS line power to the changes in the line series reactance inserted by the FACTS device. The power oscillation damping controller is based on a time-discrete, non-linear approach which aims to damp the power oscillations and set the desired power flow on the FACTS line by means of two step changes in the line reactance separated in time by half an oscillation cycle.</p><p>A verification of the proposed controllers was done by means of digital simulations using power system models of different complexities. The CSC and DPFC controllers were shown to significantly improve the small-signal- and transient stability in one four-machine system of a type commonly used to study inter-area oscillations. The CSC controller was also tested for 18 different contingencies in a 23-machine system, resulting in an improvement in both the system transient stability and the damping of the critical oscillation mode. </p>
15

Aspects on Dynamic Power Flow Controllers and Related Devices for Increased Flexibility in Electric Power Systems

Johansson, Nicklas January 2011 (has links)
This thesis studies different aspects of Flexible AC Transmission System (FACTS) devices which are used to improve the power transfer capability and increase the controllability in electric power systems. In the thesis, different aspects on the usage and control of Dynamic Power Flow Controllers (DPFC) and related FACTS devices are studied. The DPFC is a combination of a Phase Shifting Transformer (PST) and a Thyristor Switched Series Capacitor (TSSC)/Thyristor Switched Series Reactor (TSSR). The thesis proposes and studies a new method, the Ideal Phase-Shifter (IPS) method, for selection and rating of Power Flow Controllers (PFC) in a power grid. The IPS method, which is based on steady-state calculations, is proposed as a first step in the design process for a PFC. The method uses the Power controller plane, introduced by Brochu et al in 1999. The IPS method extends the usage of decoupling methods in the Power controller plane to a power system of arbitrary size. The IPS method was in the thesis used to compare the ratings of different PFC:s required to improve the power transfer capability in two test systems. The studied devices were here the PST, the TSSC/TSSR and the DPFC. The thesis treats control of ideal Controlled Series Capacitors (CSC), TCSC, TSSC/TSSR, and DPFC. The goals of the FACTS controllers which are developed are Power Oscillation Damping (POD), fast power flow control, and transient stability improvement in the power system. New adaptive control strategies for POD and power flow control are proposed and studied in different models of power systems by time-domain simulations. A strategy for transient stability improvement is also proposed and studied. Additionally, different methods for study of Subsynchronous Resonance (SSR), which is associated with series compensation in power systems, are investigated. Here, four of the most common methods for frequency scanning to determine the electrical damping of subsynchronous oscillations in a power grid are studied. The study reveals significant differences of the electrical damping estimates of the studied standard methods when applied to a four-machine test system. / QC 20110819
16

Aplicação do algoritmo bioinspirado Novel Bat Algorithm na parametrização dos controladores suplementares de amortecimento e dispositivo FACTS GUPFC /

Miotto, Ednei Luiz January 2018 (has links)
Orientador: Percival Bueno de Araujo / Resumo: Este trabalho apresenta o Novel Bat Algorithm com uma nova técnica para realizar o ajuste coordenado dos parâmetros de controladores suplementares de amortecimento (Estabilizadores de Sistemas de Potência e do conjunto Generalized Unified Power Flow Controller – Power Oscillation Damping) em sistemas elétricos de potência multimáquinas. O objetivo principal é inserir amortecimento adicional aos modos oscilatórios de baixa frequência e, consequentemente, garantir a estabilidade do sistema elétrico frente a pequenas perturbações. Para representar o sistema elétrico de potência será utilizado o Modelo de Sensibilidade de Potência. Desse modo, todos os seus dispositivos e componentes foram modelados por injeções de potência. Análises estáticas e dinâmicas foram realizadas em dois sistemas teste, sendo: o Sistema Simétrico de Duas Áreas e o Sistema New England. A eficiência do dispositivo FACTS Generalized Unified Power Flow Controller atuando em conjunto com uma estrutura de controle baseada em controladores Proporcional – Integral foi criteriosamente avaliada para o controle de fluxos de potências ativa e reativa, para a melhoria do perfil de tensão do sistema elétrico e na redução das perdas no sistema de transmissão. O desempenho do Novel Bat Algorithm, no que concerne ao ajuste dos parâmetros dos controladores, foi comparado a outros quatro algoritmos bio-inspirados bastante difundidos na literatura: Particle Swarm Optimization, Bacterial Foragim Optimization, Bat Algorithm e... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This work presents the Novel Bat Algorithm as a new technique for the to perform the coordinated tuning of the parameters of the supplementary damping controllers (Power Systems Stabilizers and Generalized Unified Power Flow Controller - Power Oscillation Damping) in multi-machine electric power systems. The main objective is to insert damping to low-frequency oscillations and thus ensure the stability of the electrical system against minor disturbances. The Power Sensitivity Model is used to represent the system. Thus, all devices and their components are modeled by power injection. Static and dynamic analyzes were performed in the two systems: the two-areas symmetric, and the New England. The performance of the proposed methodology (Novel Bat Algorithm), for tuning of the parameters of the controllers was compared to four other algorithms, presented in the literature: The Particle Swarm Optimization method, Bacterial Foraging Optimization method, Bat Algorithm method and a Genetic Algorithm with elitism. The results demonstrated that the Novel Bat Algorithm was more effective than the other techniques presented, generating robust solutions when variations on the scenarios of loads were considered, and therefore accredited it as a tool in the analysis of the study of small-signal stability. / Doutor
17

Aplicação do algoritmo bioinspirado Novel Bat Algorithm na parametrização dos controladores suplementares de amortecimento e dispositivo FACTS GUPFC / Application of the bio-inspired technique Novel Bat Algorithm in the parameterization of the additional damping controllers and FACTS GUPFC device

Miotto, Ednei Luiz 18 October 2018 (has links)
Submitted by Ednei Luiz Miotto (edneimiotto@utfpr.edu.br) on 2018-11-05T12:58:43Z No. of bitstreams: 1 TESE EDNEI LUIZ MIOTTO.pdf: 5057627 bytes, checksum: 74b7d6f2bd477e7e02941873ca291fa3 (MD5) / Approved for entry into archive by Cristina Alexandra de Godoy null (cristina@adm.feis.unesp.br) on 2018-11-08T19:07:02Z (GMT) No. of bitstreams: 1 miotto_el_dr_ilha.pdf: 5057627 bytes, checksum: 74b7d6f2bd477e7e02941873ca291fa3 (MD5) / Made available in DSpace on 2018-11-08T19:07:02Z (GMT). No. of bitstreams: 1 miotto_el_dr_ilha.pdf: 5057627 bytes, checksum: 74b7d6f2bd477e7e02941873ca291fa3 (MD5) Previous issue date: 2018-10-18 / Este trabalho apresenta o Novel Bat Algorithm com uma nova técnica para realizar o ajuste coordenado dos parâmetros de controladores suplementares de amortecimento (Estabilizadores de Sistemas de Potência e do conjunto Generalized Unified Power Flow Controller – Power Oscillation Damping) em sistemas elétricos de potência multimáquinas. O objetivo principal é inserir amortecimento adicional aos modos oscilatórios de baixa frequência e, consequentemente, garantir a estabilidade do sistema elétrico frente a pequenas perturbações. Para representar o sistema elétrico de potência será utilizado o Modelo de Sensibilidade de Potência. Desse modo, todos os seus dispositivos e componentes foram modelados por injeções de potência. Análises estáticas e dinâmicas foram realizadas em dois sistemas teste, sendo: o Sistema Simétrico de Duas Áreas e o Sistema New England. A eficiência do dispositivo FACTS Generalized Unified Power Flow Controller atuando em conjunto com uma estrutura de controle baseada em controladores Proporcional – Integral foi criteriosamente avaliada para o controle de fluxos de potências ativa e reativa, para a melhoria do perfil de tensão do sistema elétrico e na redução das perdas no sistema de transmissão. O desempenho do Novel Bat Algorithm, no que concerne ao ajuste dos parâmetros dos controladores, foi comparado a outros quatro algoritmos bio-inspirados bastante difundidos na literatura: Particle Swarm Optimization, Bacterial Foragim Optimization, Bat Algorithm e o Algoritmo Genético com Elitismo. Os resultados demonstraram que o Novel Bat Algorithm foi mais eficiente que as demais técnicas avaliadas, obtendo soluções com amortecimento satisfatório, mesmo quando variações nos cenários de carregamento do sistema são consideradas, sendo, portanto, credenciado como ferramenta promissora para a análise da estabilidade a pequenas perturbações em sistemas elétricos de potência multimáquinas. / This work presents the Novel Bat Algorithm as a new technique for the to perform the coordinated tuning of the parameters of the supplementary damping controllers (Power Systems Stabilizers and Generalized Unified Power Flow Controller - Power Oscillation Damping) in multi-machine electric power systems. The main objective is to insert damping to low-frequency oscillations and thus ensure the stability of the electrical system against minor disturbances. The Power Sensitivity Model is used to represent the system. Thus, all devices and their components are modeled by power injection. Static and dynamic analyzes were performed in the two systems: the two-areas symmetric, and the New England. The performance of the proposed methodology (Novel Bat Algorithm), for tuning of the parameters of the controllers was compared to four other algorithms, presented in the literature: The Particle Swarm Optimization method, Bacterial Foraging Optimization method, Bat Algorithm method and a Genetic Algorithm with elitism. The results demonstrated that the Novel Bat Algorithm was more effective than the other techniques presented, generating robust solutions when variations on the scenarios of loads were considered, and therefore accredited it as a tool in the analysis of the study of small-signal stability.
18

Investigations On Small Signal Stability Of Power Systems Affected By FACTS Supplementary Modulation Controllers

Saikumar, H V 09 1900 (has links) (PDF)
No description available.
19

Performance Evaluation Of Distance Relays For FACTS Compensated Transmission Lines

Maturu, Suresh 03 1900 (has links) (PDF)
With limited enhancement or expansion of the transmission infrastructure, the contemporary power systems are operating under more stressed conditions. It becomes important to fully utilize the existing transmission system to supply load demand as much as possible, thus eliminating or reducing the need for new transmission investment. Flexible AC Transmission System (FACTS) technology provides an alternative to fully utilize the existing transmission lines as well as new and upgraded lines, by controlling power and also enhancing the power transfer capability of transmission lines. However, the implementation of FACTS controllers in the transmission system has introduced new power system dynamics that must be addressed in the area of power system protection, such as rapid changes in line impedance, power angle, line currents, transients introduced by the occurrence of fault and associated control action of the FACTS controller. Therefore, the performance of the protection system must be carefully analyzed in the presence of FACTS controllers. The thesis aims at evaluating the performance of distance relays when different types of FACTS controllers, in particular Voltage Source Converter (VSC) based FACTS controllers, are incorporated at the midpoint of the transmission system to achieve voltage profile improvement and power transfer capability. The detailed models of these controllers and their control strategies are described. The presence of FACTS controllers in the loop affects both steady state and transient components of voltage and current signals. The rapid response of FACTS controllers to different power system configurations significantly affects the apparent impedance seen by distance relays. The apparent impedance seen by distance relays would be different from that of the system without FACTS controller. Due to this, the distance relay may malfunction, resulting in unreliable operation of the power system during faults. Furthermore, the effect of FACTS controllers on distance relay operation depends on the type of FACTS controller used, the application for which it has been installed and its location in the power system. The distance relay is evaluated for different loading conditions and for various fault conditions. Simulation studies are carried out using PSCAD/EMTDC based transient simulation package.
20

Investigation of the application of UPFC controllers for weak bus systems subjected to fault conditions. An investigation of the behaviour of a UPFC controller: the voltage stability and power transfer capability of the network and the effect of the position of unsymmetrical fault conditions.

Jalboub, Mohamed K. January 2012 (has links)
In order to identify the weakest bus in a power system so that the Unified Power Flow Controller could be connected, an investigation of static and dynamic voltage stability is presented. Two stability indices, static and dynamic, have been proposed in the thesis. Multi-Input Multi-Output (MIMO) analysis has been used for the dynamic stability analysis. Results based on the Western System Coordinate Council (WSCC) 3-machine, 9-bus test system and IEEE 14 bus Reliability Test System (RTS) shows that these indices detect with the degree of accuracy the weakest bus, the weakest line and the voltage stability margin in the test system before suffering from voltage collapse. Recently, Flexible Alternating Current Transmission systems (FACTs) have become significant due to the need to strengthen existing power systems. The UPFC has been identified in literature as the most comprehensive and complex FACTs equipment that has emerged for the control and optimization of power flow in AC transmission systems. Significant research has been done on the UPFC. However, the extent of UPFC capability, connected to the weakest bus in maintaining the power flows under fault conditions, not only in the line where it is installed, but also in adjacent parallel lines, remains to be studied. In the literature, it has normally been assumed the UPFC is disconnected during a fault period. In this investigation it has been shown that fault conditions can affect the UPFC significantly, even if it occurred on far buses of the power system. This forms the main contribution presented in this thesis. The impact of UPFC in minimizing the disturbances in voltages, currents and power flows under fault conditions are investigated. The WSCC 3-machine, 9-bus test system is used to investigate the effect of an unsymmetrical fault type and position on the operation of UPFC controller in accordance to the G59 protection, stability and regulation. Results show that it is necessary to disconnect the UPFC controller from the power system during unsymmetrical fault conditions. / Libyan Government

Page generated in 0.0621 seconds