• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 139
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 145
  • 60
  • 36
  • 35
  • 31
  • 30
  • 27
  • 24
  • 23
  • 21
  • 19
  • 19
  • 16
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Avaliação da adesão de Staphylococcus spp. em resina acrílica específica para prótese ocular e alteração de cor de botões de íris artificiais, variando a cor e as técnicas de obtenção, ambos após desinfecção química

Moreno, Amália [UNESP] 13 June 2014 (has links) (PDF)
Made available in DSpace on 2015-05-14T16:53:34Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-06-13Bitstream added on 2015-05-14T16:58:38Z : No. of bitstreams: 1 000821328.pdf: 1693611 bytes, checksum: 2f11602ee222c6ad0cb896f0664f78e8 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / As próteses oculares são responsáveis pela recuperação da estética e auto-estima do usuário. Assim, os materiais utilizados na confecção de prótese ocular devem possuir propriedades específicas para sua indicação e durabilidade principalmente aos procedimentos de desinfecção pelo paciente. Desse modo, este estudo teve como objetivo verificar a efetividade de diferentes soluções desinfetantes na remoção de biofilme de duas espécies de Staphylococcus spp., desenvolvidas na superfície de resina acrílica específica para prótese ocular e avaliar a alteração de cor de botões de íris artificiais confeccionadas por diferentes técnicas antes e após a polimerização e quando influenciadas pela desinfecção química. Para o teste de microbiologia, 396 amostras em resina acrílica para prótese ocular N1 foram confeccionadas (1,0 cm em diâmetro e 0,3 cm em espessura), sendo metade dessas amostras para formação de biofilme de S. epidermidis e a outra metade para formação de biofilme de S. aureus, ambos na superfície da amostra. Para cada cepa bacterina, 66 amostras foram submetidas a formação de biofilme em sua superfície durante três diferentes tempos: inicial (24h), intermediário (48h) e maduro (72h). Em seguida as amostras foram distribuídas aleatoriamente (unidade amostral n=6) para um dos tratamentos desinfetantes: água destilada durante 10, 15, 30 min e 6 h (controle-CTL); sabão neutro (NES) durante 30 min; Opti-Free durante 30 min e 6 h; Efferdent (EFF) durante 15 min; e gluconato de clorexidina (0,5%; 2% e 4%) (CHX) durante 10 min. Após o tratamento desinfetante, as amostras acrílicas foram imediatamente agitadas para desprendimento do biofilme. A contagem de colônias foi verificada por análise do número de UFC/mL. Para a análise de alteração de cor 300 amostras simulando próteses oculares foram confeccionadas, sendo metade... / Considering that ocular prostheses restore esthetics and patient’s self-esteem, the materials used for prosthesis fabrication should present appropriate properties regarding indication and reliability after the disinfection procedures. So, the aim of this study was to assess the effectiveness of different disinfectant solutions against two species of Staphylococcus spp. cultured on ocular prosthesis acrylic resin. In addition, the chromatic change of artificial iris buttons fabricated with different techniques was also evaluated before and after polymerization and disinfection. For the microbiology tests 396 acrylic specimens were fabricated (1.0 cm in diameter and 0.3 cm in thickness). Half of the samples were made for biofilm formation of S. epidermidis and half were made for biofilm formation of S. aureus, both on the sample surface. For each strain, 66 samples were underwent to biofilm formation on the liner surface for three different points: initial (24h), intermediate (48h) and mature (72h). Afterwards the specimens were randomly assigned (unit sample n = 6) to one of disinfectant treatments: distilled water for 10, 15, 30 min and 6 h (control-CTL); treated with neutral soap (NES) for 30 min; treated with Opti-Free (OPT) for 30 min and 6 h; treated with Efferdent (EFF) for 15 min; and treated with (0.5%, 2% and 4%) chlorhexidine gluconate (CHX) for 10 min. After the treatments, the specimens were vortexed to disrupt the biofilm, and residual cells were counted (cell/mL). For the color meansurations a total of 300 samples simulating ocular prosthesis were fabricated. Half of the samples were made with blue artificial irises, and half were made with brown artificial irises. For each color, 50 samples were fabricated according to one of the following techniques: PE - conventional technique, CA - prefabricated... / FAPESP: 11/05864-8
102

Influência da pigmentação, técnica de união e envelhecimento acelerado sobre a resistência de união entre resina acrílica e silicone facial

Haddad, Marcela Filié [UNESP] 28 June 2013 (has links) (PDF)
Made available in DSpace on 2014-08-13T14:50:52Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-06-28Bitstream added on 2014-08-13T18:00:07Z : No. of bitstreams: 1 000764939.pdf: 4285251 bytes, checksum: 9da5ef190038848837a8d33e81f903b8 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Próteses maxilofaciais retidas por implantes necessitam de uma infraestrutura acrílica, na qual ficam contidos os sistemas de retenção; contudo, a união resina acrílica-silicone facial não é estável. Assim, este estudo teve como objetivo avaliar a influência da pigmentação com nanopartículas, técnica de união e envelhecimento acelerado sobre a resistência de união entre resina acrílica e silicone facial. Para tal, foram confeccionadas 960 amostras que consistiam em uma barra de resina acrílica de ativação química aderida ao silicone facial Silastic MDX 4-4210 incolor ou pigmentado com nanopartículas (tinta a óleo e/ou opacificador a base de sulfato de bário). A adesão entre os dois materiais foi feita pela simples deposição do silicone sobre a resina acrílica (N); por retenções mecânicas, representadas por ranhuras (R); aplicação do primer de uso médico (DC 1205 Prime - DC); primer para material reembasador (Sofreliner Primer MS- SF) ou adesivo de uso médico (Silatic Medical Adhesive Type A - A) isolados ou associados. Desta maneira, as amostras foram divididas em 4 grupos (n=240), de acordo com a nanopartícula adicionada ou não, sendo Grupo 1: Incolor; Grupo 2: Tinta a óleo; Grupo 3: Opacificador; e Grupo 4: Tinta a óleo e opacificador. Estes grupos foram divididos em 12 subgrupos (n=20), de acordo com o meio utilizado para unir a resina acrílica ao silicone, sendo: Subgrupo I: N; Subgrupo II: A; Subgrupo III: DC; Subgrupo IV: DC+A; Subgrupo V: SF; Subgrupo VI: SF+A; Subgrupo VII: R; Subgrupo VIII: R+A; Subgrupo IX: R+DC; Subgrupo X: R+DC+A; Subgrupo XI: R+SF; Subgrupo XII: R+SF+A. Metade das amostras de... / Maxillofacial prosthesis retained by implants use an acrylic framework to fit the attachment systems. However, the bond between acrylic resin and facial silicone is instable. Therefore, this study investigated the influence of nanoparticles pigments, adhesive system and accelerated aging on the bond strength between the acrylic resin and facial silicone. A total of 960 specimens made of selfpolymerized acrylic resin bar adhered to Silastic MDX 4-4210 facial silicone either colorless or pigmented with nanoparticles (oil tint and/or barium sulfate opacifier) were fabricated. The union between the two materials was performed in different ways: no treatment on the acrylic bar (N), mechanical retentions represented by scratches (R), application of prime for medical use (DC 1205 Prime - DC), primer for soft liner material (Sofreliner Primer MS - SF), and adhesive for medical use (Silastic Medical Adhesive Type A - A) alone or in combinations. The specimens were divided into 4 groups (n=240) according to the nanoparticle presence: Group 1: colorless; Group 2: oil tint; Group 3: opacifier; and Group 4: oil tint and opacifier. These groups were divided into 12 subgroups (n=20) according to the surface treatment used to bond the facial silicone to the acrylic resin: Subgroup I: N; Subgroup II: A; Subgroup III: DC; Subgroup IV: DC+A; Subgroup V: SF; Subgroup VI: SF+A; Subgroup VII: R; Subgroup VIII: R+A; Subgroup IX: R+DC; Subgroup X: R+DC+A; Subgroup XI: R+SF; Subgroup XII: R+SF+A. Half of the specimens of each subgroup (n=10) were subjected to bond strength test at the baseline period in a universal testing machine at a crosshead speed of 10 mm/min until failure. The other specimens were exposed to the accelerated... / FAPESP: 10/02937-1
103

Influência da adição de nanopartículas sobre a dureza, resistência à ruptura e deformação permanente de silicone facial submetido ao envelhecimento acelerado

Nobrega, Adhara Smith [UNESP] 20 February 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:30Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-20Bitstream added on 2015-03-03T12:06:36Z : No. of bitstreams: 1 000795003.pdf: 1118199 bytes, checksum: 98a54dea093e378451b9a2f7d2e032e2 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Apesar de satisfatórias, as próteses maxilofaciais apresentam limitações quanto à estética, conforto e durabilidade. Por isso estudos com o objetivo de melhorar as propriedades desses materiais são incessantes. É comprovada a eficiência da adição de nanopartículas na proteção de silicones, evitando a degradação da sua cor, no entanto a literatura é escassa quando se refere a outras alterações das propriedades físicas causadas no silicone facial. Assim, o objetivo deste estudo é avaliar a influência da adição de nanopartículas na ruptura, deformação permanente e dureza do Silicone Facial Silastic MDX4-4210. Foram confeccionadas 560 amostras em silicone facial, sendo 280 dessas amostras para o teste de ruptura, 140 para o teste de dureza e 140 para o teste de deformação permanente. As nanopartículas adicionadas na confecção das amostras de silicone foram: óxido de zinco (ZnO); sulfato de bário (BaSO4) e dióxido de titânio (TiO2). Para cada teste (exceção do teste de ruptura, no qual a quantidade de amostras será confeccionada em duplicata), 40 amostras de silicone serão confeccionadas com adição de cada um dos tipos de nanopartículas, totalizando 120 amostras; 10 amostras de silicone com tinta a óleo, sem nanopartículas, e 10 amostras somente de silicone .Para cada tipo de nanopartícula adicionada ao silicone facial, 20 amostras foram confeccionadas na concentração de 1% e 20 na concentração de 2%. Para cada concentração de nanopartículas, metade (10 amostras) foi com adição de tinta a óleo e a outra metade sem tinta a óleo. As amostras foram submetidas aos ensaios de dureza, resistência à ruptura e deformação permanente, e 1008 horas de envelhecimento acelerado. Os dados obtidos foram submetidos à análise estatística, utilizando-se os testes de nested ANOVA e teste de Tukey. Pode-se... / Although satisfactory, the maxillofacial prostheses present aesthetics, comfort and durability limitations. Therefore, studies with the purpose to obtain better properties of these materials are unceasing. The efficiency of adding nanoparticles to silicon protection is well proven in preventing its color degradation, however the literature is scarce when it comes to other physical property changes with infacial silicon.The aim of this study is to evaluate the influence of nanoparticles addition to hardness, rupture resistance and permanent deformation of Facial Silicone Silastic MDX4-4210. 560 samples of facial silicone were made, 280 for rupture resistance test, 140 for hardness test and 140 for permanent deformation test. Nanoparticles added in the preparation of silicone samples were zinc oxide (ZnO), barium sulfate (BaSO4) and titanium dioxide (TiO2). For each test (except the rupture test, in which the samples are duplicated), 40 samples will be made of silicon added to each type of nanoparticles, totaling 120 samples, 10 samples of silicone with oil paint without nanoparticles, and 10 samples only of silicone (control group). For each type of nanoparticle added to the facial silicone, 20 samples were prepared at a concentration of 1% and 20 at a concentration of 2%. For every concentration of nanoparticles, half (10 samples) were added oil paint and the other half without oil paint. Samples were submitted to testing hardness, rupture resistance and permanent deformation, and 1008 hours of accelerated aging. The data were subjected to statistical analysis using nested ANOVA and Tukey tests. It can be verified through the results that the presence of nanoparticles influenced the hardness, tear strength and permanent deformation of the assessed groups. We conclude that all evaluated nanoparticles influenced the hardness, tear strength and permanent... / FAPESP: 12/05270-3
104

Desenvolvimento de um programa de análise de imagens radiológicas de membros inferiores com osteoartrite de joelho a partir de parâmetros biomecânicos funcionais

Lemos, Fernando de Aguiar January 2010 (has links)
A osteoartrite (OA) de joelho é uma doença multifatorial que acomete pessoas a partir da terceira década de vida, mas com maior incidência em idosos. Sua classificação é feita baseado em parâmetros clínicos e qualitativos durante uma intervenção médica. Nos casos mais avançados, a cirurgia de artroplastia de joelho envolve não apenas a substituição da articulação por uma prótese, mas também o realinhamento dos segmentos do membro inferior. Nesse caso há a necessidade de uma abordagem mais quantitativa na busca do reposicionamento desta articulação em relação ao eixo de suporte da carga corporal (ESCC). O objetivo deste estudo foi desenvolver uma metodologia de análise que possibilitasse quantificar uma série de parâmetros estruturais e funcionais a partir de imagens da raios-X em sujeitos saudáveis, assintomáticos para OA e em sujeitos com diagnóstico de OA de joelho. Este estudo utilizou-se da classificação adotada por Dejour (1991) para a classificação dos sujeitos em grupos com diferentes graus de OA. A amostra foi constituída de sujeitos de 25 a 80 anos com níveis de grau 1, grau 2 e grau 3 de OA. Além da classificação nos graus, os sujeitos foram separados pela presença ou não de dor em assintomáticos (OA sem dor) e sintomáticos (OA com dor). Imagens de raios-X foram obtidas do membro inferior dos sujeitos. Previamente à obtenção das imagens, um sistema de calibração foi construído com o objetivo de identificar possíveis erros de medidas e corrigi-los. Além disso, o sistema de calibração também foi utilizado na definição exata da metodologia a ser utilizada na obtenção dos exames radiográficos a fim de que a quantificação dos parâmetros estruturais e funcionais de cada membro inferior não apresentasse fatores intervenientes que pudessem mascarar os resultados obtidos de cada imagem digital, possibilitando também a comparação entre os indivíduos. Após a identificação dos fatores de correção das imagens digitais, um programa foi desenvolvido na plataforma Matlab para a identificação das variáveis geométricas dos membros inferiores. Além disso, também foi desenvolvida uma rotina matemática que permitiu calcular, por meio da de decomposição de vetores de força, as cargas que atravessavam cada articulação do joelho. Com estas informações foi possível comparar as variáveis geométricas dos membros inferiores entre os diferentes níveis de OA e também observar por meio de três modelos matemáticos qual a influência destas variáveis no mínimo espaço intra-articular medial (MEIAM), na força no compartimento medial (FCM) e nas estruturas contra-laterais a este compartimento, como o ligamento colateral lateral e trato iliotibial, neste trabalho denominados de força P. Os principais resultados obtidos no presente estudo foram: (1) o desenvolvimento de uma metodologia de calibração de imagens digitais capaz de reduzir os efeitos da ampliação da imagem, corrigindo os valores ampliados aproximando-os dos valores reais; (2) Foi observado que o desalinhamento dos membros inferiores avaliado pelo ângulo que representa a relação entre o quadril, joelho e tornozelo (QJT) tem influência na OA de joelho, assim como o ângulo entre os platôs condilares do fêmur e da tíbia (PC). Visto que quanto maior estes ângulos, menor o mínimo espaço intra - articular medial (MEIAM) e maior os graus de OA. 3) Quando avaliado as variáveis geométricas dos membros inferiores em um teste de regressão linear múltipla, para saber a influência na força do compartimento medial (FCM), na força do ligamento colateral lateral e tracto iliotibial (força P) e no MEIAM, o QJT teve maior poder explicativo tanto para as cargas como o MEIA, confirmando a teoria mecânica. Entretanto o ângulo do colo do fêmur (ACF), apesar de uma baixa participação (6%) que mostrou um grau de importância significativo nos modelos de carga do compartimento e do MEIAM. Assim, embora nós saibamos que os segmentos inferiors ajustam-se mecanicamente em relação a carga, foi observado que o desalinhamento dos membros inferiores é um fator de risco mais importante entre todas as variáveis para o desenvolvimento da OA. / Knee osteoarthritis (OA) is a multifactorial disease that affects people from the third decade of life, but with higher incidence in the elderly. Its classification is based on clinical and qualitative parameters during a medical intervention. In more advanced cases of OA, knee arthroplasty involves not only joint replacement with prosthesis, but also the realignment of the lower limb segments. In this case, there is a need for a more quantitative approach in the pursuit of the joint repositioning in relation to the load bearing axis (LBA). The aim of this study was to develop a methodology that would enable the quantification of a number of structural and functional parameters, using X-ray images, in healthy subjects, asymptomatic for OA and subjects diagnosed with knee OA. This study used the classification adopted by Dejour (1991) to classify the subjects into groups with different degrees of OA. The sample consisted of subjects between 25 and 80 years old, classified with levels 1, 2 and 3 of OA. Besides this classification, subjects were separated by the presence or absence of pain into asymptomatic (OA without pain) and symptomatic (OA with pain). Radiographic images of the lower limb were obtained of the subjects. Prior to obtaining the images, a calibration system was built to identify possible measurement errors and correct them. In addition, the calibration system was also used to define the exact methodology to be used to obtain the images, so that the quantification of structural and functional parameters of each lower limb did not present intervening factors that might mask the results, allowing also the comparison between individuals. After identifying the correction factors of the digital images, a Matlab routine was developed to identify the geometric variables of the lower limbs. In addition, this routine also allowed the calculation, through the decomposition of force vectors, of the loads that cross each knee joint. With this information, it was possible to compare the geometric variables of the lower limbs between different levels of OA and also observe, by means of three mathematical models, the influence of these variables on the medial intra-articular minimum space, on the force in the medial compartment (FMC) and on the contra-lateral structures in this compartment, such as the lateral collateral ligament and the iliotibial tract, called, in this work, P force. The main results of this study were: (1) the development of a calibration methodology for digital images capable of reducing the effects of image magnification, adjusting the values closer to real values; (2) the observation that the misalignment of the lower extremities, evaluated by the angle that represents the relationship between hip, knee and ankle (HKA), has an influence on knee OA, as well as the angle between the condyle plateaus of the femur and the tibia. The larger this angle is, smaller is the medial intra-articular minimum space, and higher are the levels of OA; (3) when evaluating the geometric variables of the lower limbs in a multiple linear regression test, to identify the influence of these variables on the force of the medial compartment (FMC), on the force of the lateral collateral ligament and the iliotibial tract (indicated here as P force) and on the MIAMS it was possible to observe that the HKA showed larger explanatory power for the loads as the MIAMS, confirming the mechanical theory. However, for the angle of the femoral neck (AFN), despite a lower power to explain the dependant variables (only 6%), it still showed a significant importance in the load compartment models and MIAMS. Thus, although we know that the segments adapt or mechanically adjust in response to load, it seems that the lower limb segments alignment is the most important factor amongst all variables as a risk factor for the development of knee OA.
105

Efeito do filme de carbono DLC aplicado por plasma como recobrimento em Polietileno de Ultra Densidade e Alto Peso Molecular (UHWPE) e planejamento virtual utilizando a técnica de elementos finitos em cirúrgias de próteses totais da ATM / The effect of DLC film applied by plasma coating deposition of Ultra High Molecular Weight Polyethylene (UHWPE) in total ATM prosthesis and it virtual planning using the FEA technique

Silva, Alecsandro de Moura [UNESP] 14 January 2016 (has links)
Submitted by ALECSANDRO DE MOURA SILVA null (alecsms@yahoo.com.br) on 2016-06-07T17:44:58Z No. of bitstreams: 1 Alecsandro final com ficha 02062016.pdf: 1266134 bytes, checksum: 8fb4b0e5bdde927d35075c9cf2dcb764 (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-06-08T20:16:23Z (GMT) No. of bitstreams: 1 silva_am_dr_sjrp.pdf: 1266134 bytes, checksum: 8fb4b0e5bdde927d35075c9cf2dcb764 (MD5) / Made available in DSpace on 2016-06-08T20:16:23Z (GMT). No. of bitstreams: 1 silva_am_dr_sjrp.pdf: 1266134 bytes, checksum: 8fb4b0e5bdde927d35075c9cf2dcb764 (MD5) Previous issue date: 2016-01-14 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho teve por objetivo avaliar o efeito do filme de carbono (DLC) aplicado por plasma como recobrimento da liga de Ti -6Al-4V e do polietileno de alto peso molecular (UHMWPE) em prótese totais de ATM, com a finalidade de melhorar suas propriedades bio-tribológicas. Outro aspecto abordado neste trabalho a aplicação do planejamento virtual utilizando a técnica de elementos finitos (FEA), na apresentação de um caso clínico, colocando a importância do cirurgião de conhecer a fundo tanto o planejamento cirúrgico quanto o desenvolvimento da prótese customizadas (TMJ), e assim evitar possíveis falhas biomecânicas. Material: Para o desenvolvimento deste trabalho primeiramente foram utilizados 40 corpos de prova de Ti-6Al-V, dos quais 15 foram recobertas com um DLC e 15 por DLC-Ag pelo método de deposição químico (PECVD), e 10 foram mantidos sem recobrimento como controle. Além disso, foram confeccionados 30 corpos de prova de UHMWPE, dos quais, 15 foram recobertas por DLC pelo sistema de deposição físico (CVD) e 15 foram mantidas sem recobrimento como controle. Métodos: Foram avaliadas as características superfíciais das amostras, adesão em simulador de fadiga deslizante reproduzindo o trabalho condili fossapo 2000,000 de ciclos em banhocom ringuer lactato a 36 graus, a uma carga 200 N. As amostras com filmes foram submetidas a teste de citotoxicidade com células osteoblásticas. Resultados: As células se mostraram uma biocompatibilidade significativa com as amostras portando filme de DLC em substrato Ti6Al4v, se mostrando inerte ao polietileno. Neste estudo também foi apresentado um caso clinico, paciente com 12 anos de idade genero feminino, portadora de anquilose bilateral da ATM relatou já ter sido submetida a cirurgias repetidas sem sucesso, apresentando deformidade esqueletal classe II, em consequência da anquilose temporomandibular, abertura bucal limitada inicial (4,9 mm) e pos cirurgico reconstrução bilateral com prótese total de ATM customizada após o ato cirúrgico, mostrou se com uma abertura de (23 mm) após um ano, com melhora significativa para alimentação e apneia severa do sono. Conclusão: O Dlc em titânio dentro dos parâmetros que conseguimos de deposição, se apresenta como promissor para cobertura de peças protéticas a serem colocadas em seres humanos por sua baixa condutividade elétrica, ótima resposta biológica. / This study aimed to evaluate the effect of carbon film (DLC) applied by plasma as coating the Ti-6Al-4V alloy and ultra high molecular weight polyethylene (UHMWPE) in total TMJ prosthesis, in order to improve their bio-tribological properties. Another aspects addressed in this work are the application of virtual planning using the technique of finite element (FEA) and the presentation of a case, placing the importance of the surgeon to know the background both surgical planning and the development of customized prosthesis (TMJ) and thus avoid possible biomechanical faults. Material: For the development of this work were first used 40 specimens of Ti-6Al-V, of which 15 were coated with a DLC and 15 DLC-Ag by chemical deposition method (PECVD), and 10 were kept without coating as control. In addition, they made 30 UHMWPE specimens, of which 15 were coated with DLC by physical deposition system (CVD) and 15 were maintained without coating as a control. Methods: The surface characteristics of the samples were evaluated for adhesion sliding fatigue tester reproducing the work condili fossapo 2000.000 cycles in banhocom ringuer lactate at 36 degrees, to a load 200 N. The film samples were subjected to cytotoxicity testing in osteoblastic cells. Results: The cells showed a significant biocompatibility with samples carrying DLC film on Ti6Al4V substrate, showing inert to the polyethylene. This study also presented a clinical case patient with 12 years of female gender age, bearer of bilateral ankylosis of the TMJ reported having been subjected to repeated unsuccessful attempts, with deformity skeletal class II, as a result of temporomandibular ankylosis, limited mouth opening initial (4.9 mm) and post surgical bilateral reconstruction with customized ATM denture after surgery, showed up with an opening (23 mm) after one year, with a significant improvement for food and severe sleep apnea. Conclusion: Dlc titanium within the parameters we can deposition, is presented as promising to cover prosthetic pieces to be placed on humans for its low electrical conductivity, good biological response.
106

Enzimas exógenas em dietas para frangos de corte /

Dourado, Leilane Rocha Barros. January 2008 (has links)
Orientador: Nilva Kazue Sakomura / Banca: Alice Eiko Murakami / Banca: Nilce Maria Soares Queiroz Gama / Banca: Euclides Braga Malheiros / Banca: Aulus cavalieri Carciofi / Resumo: Foram conduzidos quatro ensaios para avaliar o uso de enzimas exógenas para frangos de corte. No primeiro ensaio foi avaliada a energia metabolizável verdadeira (EMV) do milho e do farelo de soja com a adição ou não de complexo enzimático xilanase, amilase, protease (XAP), de xilanase e de fitase, utilizando o método de alimentação precisa com galos. Foi verificada melhoria de 2,3% na EMV do milho com adição de fitase. No segundo ensaio foi avaliada a energia metabolizável aparente (EMA) do milho com a adição ou não de amilase, xilanase, fitase, complexo XAP, combinação de XAP e fitase e com adição de complexo xilanase/pectinase/ßglucanase (XPBG), utilizando o método de coleta total (pintos). O milho foi suplementado com macro e microminerais. A adição das enzimas promoveu melhoria na EMA do milho entre 1,26 a 2,11%, exceto com o complexo XPBG. No terceiro ensaio foi avaliado o efeito do tipo de milho (seco no campo e artificialmente) e a eficiência de utilização de XAP em dietas com redução de 125kcal na EMA, comparada a dietas formuladas para atender as exigências das aves, sobre a digestibilidade ileal e desempenho de frangos. A adição de enzimas não promoveu respostas sobre o desempenho, entretanto, melhorou a digestibilidade de alguns nutrientes e a energia digestível das dietas...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Four trials were conduced to evaluate enzymes use for broilers. In the first trial the true metabolizable energy (TME) of corn and soybean meal was evaluated with or without addition of enzymatic blend (xylanase, amylase, protease - XAP), of xilanase and of fitase, using the forced feeding method with roosters. The improvement of 2.3% was observed in corn TME with fitase addition. In the second trial the apparent metabolizable energy (AME) of corn (supplied with macro and micro minerals) with or without enzyme addition using total collection technique. The enzymes were: amylase; xylanase; phytase; XAP; XAP and phytase combination; xylanase/pectinase/ßglucanase (XPBG) blend. The enzymes addition provided increase on corn AME between 1.26% to 1.66%, except with XPBG addition. In the third trial, was evaluated the effect of the corn type (field dried and oven dried) and the efficiency of use of XAP in diets with reduction of 125kcal in EMA (NC), compared to diets formulated to assist the birds requirements (PC), under nutrient digestibility and performance of broilers. The effect of enzyme addition and corn type in digestibility coefficient of minerals was observed. The birds fed oven dried corn showed better digestibility results in all evaluated variables. In conclusion, the nutrients digestibility showed the positive effect with enzyme addition on NC...(Complete abstract click electronic access below) / Doutor
107

Para um estudo da estruturação ritmica na fala disartrica / Towards a study of the rhythmic structural in dysarthric speech

Vieira, Jussara Melo 23 February 2007 (has links)
Orientador: Plinio Almeida Barbosa / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Estudos da Linguagem / Made available in DSpace on 2018-08-10T11:46:05Z (GMT). No. of bitstreams: 1 Vieira_JussaraMelo_D.pdf: 3447938 bytes, checksum: baa53bcff3e3572313562da26d96e687 (MD5) Previous issue date: 2007 / Resumo: A disartria é uma desordem da fala decorrente de comprometimentos neuromusculares. Tais comprometimentos podem causar alterações na respiração, na fonação, na ressonância e na articulação da fala. Estes comprometimentos podem ser decorrentes de traumatismo craniano (TC). O TC é uma agressão cerebral resultante de uma pancada na cabeça e/ou uma queda com fratura craniana. Na fala disártrica pode haver, também, falha no mecanismo velofaríngeo devido à paralisia/paresia do palato mole. Neste caso, o resultado acústico para a fala é a hipernasalidade e a emissão de ar nasal, que podem ser tratadas através do uso de uma prótese de palato elevadora (PPE). Na disartria, o ritmo da fala também pode estar alterado, implicando alterações nos locais de acento frasal (AF), na inserção e na duração das pausas silenciosas (PS). Sendo assim, interessou-nos investigar a estruturação rítmica da fala disártrica decorrente de TC. Para tanto, obtivemos a colaboração de uma falante disártrica, usuária de PPE, falante nativa do português brasileiro (PB) acometida por TC. O estudo desta fala isártrica teve como objetivos: comparar as condições de uso e não uso da PPE; comparar a estruturação rítmica da fala disártrica brasileira (FDB) com uma fala sem comprometimentos (FSC); comparar a estruturação rítmica da FDB com uma fala isártrica francesa (FDF); estudar a relação sintaxeprosódia na estruturação rítmica da fala tanto na comparação com a FSC quanto na comparação com a FDF; adquirir melhor entendimento da fala disártrica pós TC, considerando o modelo de ritmo da fala para o PB de Barbosa (2006). Para cumprir estes objetivos, acompanhamos o tratamento com PPE da falante disártrica de 1995 a 2005. Neste período coletamos e analisamos oito leituras de um mesmo texto realizadas por ela usando a PPE e duas leituras sem esta prótese: uma em 1995 e outra em 2005. A FSC correspondeu à leitura do mesmo texto da FDB. A FDF correspondeu à leitura de outro texto francês. Nestas leituras realizamos análises acústicas e de sua organização rítmica em unidades vogal-vogal (VV), grupos acentuais (GA), AF e PS. Nas análises das oito leituras da FDB houve redução no número de PS, redução da participação das PS na duração do texto lido e aumento da taxa de elocução (TE). A estruturação rítmica da FDB com e sem a prótese foi a mesma. Houve diferença significante entre a FDB e a FSC para a TE e para a duração das PS, mas não para a duração dos GA nem para o número de unidades VV. Na comparação entre a FDB e a FDF não houve diferenças significativas quanto à TE, taxa de articulação e número de unidades VV por GA. Na relação sintaxe-prosódia, as marcas sintáticas IDF (independência forte) e COORD (independência de uma conjunção coordenada) foram significativas tanto para a FDB quanto para a FSC. Mas não para a FDF. Nosso trabalho contribuiu para destacar a pertinência de estudos que considerem a relação dinâmica entre fatores biomecânicos e lingüísticos da fala, notadamente para a fala comprometida e, em especial, para a fala disártrica pós TC / Abstract: Dysarthria is a speech disorder caused by neuromotors problems. These neuromotors problems may cause breath, phonation, resonance and speech articulation disturbance. The cause of these neuromotors problems can be the traumatic brain injury (TBI). TBI is a lesion that result of cerebral aggression, a collision in the head/or a fall happening cranial breaking. Dysarthric speech can have too velopharyngeal dysfunction by total/partial paralysis soft palate. In case of soft palate palsy the hypernasality may be present, with emission of nasal air during oral sounds. In order to deal with hypernasality and nasal air emission a palatal lift (PL) is indicated. The use of PL stimulates the correct movement of the soft palate, which produces the appropriate closure of the velopharyngeal port. Rhythm speech can be altered in dysarthric speech. We realize then a study of the rhythmic structure of the dysarthric speech by TBI. For doing so, eight dysarthric speaker?s readings during prosthesis treatment with the palatal lift, are compared with readings without prosthesis, with a reference speaker and a French dysarthric speaker. These comparisons are done by analyzing vowel-to-vowel units (VV), stress groups, phrase stress and silent pauses under the theoretical framework of Barbosa (2006)?s speech rhythm model applied to Brazilian Portuguese. In the eight readings of the Brazilian dysarthric speaker, there were reductions on the number of silent pauses and pause occurrence. An increase of speech rate was also observed. The results showed that there is no distinction in rhythmic structure with and without prosthesis. The comparative analysis between the Brazilian dysarthric speaker and the reference speaker showed significant differences in speech rate and silent pause duration, but no significant difference in the duration of stress groups or in the number of VV units. The comparative analysis between the Brazilian dysarthric speaker and the French dysarthric speaker showed no significant differences in speech rate, articulation rate and number of VV units inside stress groups. As regards the syntax-prosody interface, the syntactic markers IDF (strong independency) and COORD (coordinated conjunction independency) were significant for both the Brazilian dysarthric and the reference speaker. However, these markers were not significant for the French dysarthric speaker. This work reinforces the importance of considering both linguistics and biomechanics aspects on the analysis of dysarthric speech / Doutorado / Doutor em Linguística
108

Proteses fixas implanto-retidas : influencia do pilar intermediario e dos ciclos de cocção da ceramica nos desajustes e nas tensões induzidas as fixações / Implant supported prosthesis : influence of abutment and porcelain firing cycles on misfit and stress around implants

Tramontino-Mesquita, Vanessa Silva, 1982- 27 February 2008 (has links)
Orientador: Guilherme Elias Pessanha Henriques / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-10T13:58:31Z (GMT). No. of bitstreams: 1 Tramontino-Mesquita_VanessaSilva_M.pdf: 2155429 bytes, checksum: 5050e6eb80efb708a774530922aee871 (MD5) Previous issue date: 2008 / Resumo: Especula-se que ciclos de cocção da cerâmica geram aumento nos desajustes marginais. Em próteses sobre implantes se imagina que possam motivar aumento das tensões induzidas às fixações, tensões estas, que podem variar em função do tipo de pilar protético intermediário entre a prótese e os implantes. Assim, o propósito deste estudo foi avaliar a influência do ciclo de cocção da cerâmica e uso de pilar intermediário no desajuste marginal e nas tensões induzidas aos implantes, produzidas por próteses parciais fixas de 3 elementos parafusadas sobre 2 implantes. Foram confeccionadas 20 infraestruturas metálicas simulando próteses parciais fixas de 3 elementos retidas por 2 implantes osseointegrados e fundidas em titânio comercialmente puro (Ti c.p.), obtidas partir de um modelo mestre. As estruturas foram dividas em 2 grupos, sendo o grupo pilar cônico composto por 10 estruturas retidas por parafusos a pilares intermediários cônicos padrão Branemark com cintas cervicais de 1 mm para peças múltiplas e o grupo UCLA composto por 10 estruturas retidas por parafusos diretamente sobre as fixações utilizando cilindros protéticos tipo UCLA com cintas cervicais de 1 mm sem contra-hexágono de travamento para peças múltiplas. As infra-estruturas de ambos os grupos sofreram simulação dos diversos ciclos de cocção da cerâmica, objetivando a avaliação dos desajustes marginais e das tensões induzidas às fixações. As tensões foram avaliadas por extensiometria e os desajustes por microscopia óptica, sendo aferidos após cada ciclo de cocção, sendo os resultados confrontados com a situação imediatamente pós-fundição (controle). Os valores das tensões foram correlacionados com os valores de desajuste marginal medidos nas interfaces entre pilares e/ou fixações e cilindros protéticos, com aumento de 120 x, obedecendo ao protocolo de aperto do parafuso único, sendo realizados na situação pós-fundição (controle) e após cada ciclo de cocção da cerâmica. Foi realizada a análise de variância em esquema de parcela subdividida, sendo a parcela os grupos de tratamento e os ciclos de cocção da cerâmica, a subparcela. O teste de Tukey foi utilizado para comparação múltipla, com nível de significância de 5%. Não houve diferença significativa (p=0,601) na indução de tensões aos implantes devido ao uso de pilar intermediário (pilar cônico: 580,06 ± 253,93gf; UCLA: 665,35 ± 173,99gf). Porém, notou-se decréscimo nos valores de tensão devido às etapas do ciclo de cocção da cerâmica. A análise do desajuste marginal revelou haver interação entre o grupo de tratamento e o ciclo de cocção da cerâmica (p=0,002), sendo que as menores médias de desajuste ocorreram antes da exposição das infraestruturas aos ciclos de cocção (pilar cônico: 118,07 ± 58,61µm; UCLA: 83,93 ± 25,63 µm). Concluiu-se que a presença de um pilar intermediário cônico em infraestruturas de 3 elementos fundidas em Ti c.p. não reduziu as tensões induzidas às fixações e que os ciclos de cocção da cerâmica causaram aumento no desajuste marginal e redução nas tensões induzidas às fixações. / Abstract: It is speculated that porcelain firing cycles cause an increase on marginal misfit. This effect is imagined to origin an increase on strains around implants, when screwing the metallic frameworks, and it is supposed to be decreased by the use of an abutment between the framework and the implant. Thus, the aim of this study was to evaluate the influence of the porcelain firing cycle and of the use of conic abutments on marginal misfit and on strains around implants originated by screwing 3-element fixed partial dentures over 2 implants. Twenty metallic frameworks were fabricated, casting commercially pure titanium, obtained from a master cast, simulating 3-element fixed partial dentures, retained by 2 implants. The structures were divided into two groups, where conic abutment group was composed by 10 structures screwed to Branemark-type conic multi-unit abutments with 1 mm cervical belts and UCLA group composed by 10 structures screwed directly to the implants using non-engaging multi-unit UCLA cylinders with 1 mm cervical belts. All the frameworks were submitted to porcelain firing cycle simulation, aiming the evaluation of marginal misfit and strains around implants. Strains were analyzed by the use of strain gauges and misfit was analyzed by an optical microscope, both after each firing cycle and the results were confronted to the as-cast situation (control). The strains values were correlated with misfit values, which was measured in the interface of the abutment or implant and the prosthetic cylinder, following the one-screw test, being achieved on the as cast situation and after each firing cycle. Multivariate analysis was applied in a sub divided parcel scheme and the treatments were considered as the parcel and the firing cycles as the sub parcel. Tukey¿s test was employed to multiple comparisons, with significance level at 5%. There was no significant difference (p=0.601) on strains around implants due to the use of the abutment (conic abutment: 580.06 ± 253.93gf; UCLA: 665.35 ± 173.99gf). However, a decrease on strains values was observed, due to the porcelain firing cycle. Misfit analysis presented an interaction between the treatment groups and the firing cycles (p=0.002). The lower misfit mean values occurred before the frameworks were exposed to the firing cycles (conic abutment: 118.07 ± 58.61µm; UCLA: 83.93 ± 25.63 µm). It is concluded that the presence of a conic abutment on a 3 elements partial fixed prosthesis cast in commercially pure titanium did not decrease strains around implants and that the porcelain firing cycles caused an increase on marginal misfit and a decrease on strains around implants. / Mestrado / Protese Dental / Mestre em Clínica Odontológica
109

Desenvolvimento de um programa de análise de imagens radiológicas de membros inferiores com osteoartrite de joelho a partir de parâmetros biomecânicos funcionais

Lemos, Fernando de Aguiar January 2010 (has links)
A osteoartrite (OA) de joelho é uma doença multifatorial que acomete pessoas a partir da terceira década de vida, mas com maior incidência em idosos. Sua classificação é feita baseado em parâmetros clínicos e qualitativos durante uma intervenção médica. Nos casos mais avançados, a cirurgia de artroplastia de joelho envolve não apenas a substituição da articulação por uma prótese, mas também o realinhamento dos segmentos do membro inferior. Nesse caso há a necessidade de uma abordagem mais quantitativa na busca do reposicionamento desta articulação em relação ao eixo de suporte da carga corporal (ESCC). O objetivo deste estudo foi desenvolver uma metodologia de análise que possibilitasse quantificar uma série de parâmetros estruturais e funcionais a partir de imagens da raios-X em sujeitos saudáveis, assintomáticos para OA e em sujeitos com diagnóstico de OA de joelho. Este estudo utilizou-se da classificação adotada por Dejour (1991) para a classificação dos sujeitos em grupos com diferentes graus de OA. A amostra foi constituída de sujeitos de 25 a 80 anos com níveis de grau 1, grau 2 e grau 3 de OA. Além da classificação nos graus, os sujeitos foram separados pela presença ou não de dor em assintomáticos (OA sem dor) e sintomáticos (OA com dor). Imagens de raios-X foram obtidas do membro inferior dos sujeitos. Previamente à obtenção das imagens, um sistema de calibração foi construído com o objetivo de identificar possíveis erros de medidas e corrigi-los. Além disso, o sistema de calibração também foi utilizado na definição exata da metodologia a ser utilizada na obtenção dos exames radiográficos a fim de que a quantificação dos parâmetros estruturais e funcionais de cada membro inferior não apresentasse fatores intervenientes que pudessem mascarar os resultados obtidos de cada imagem digital, possibilitando também a comparação entre os indivíduos. Após a identificação dos fatores de correção das imagens digitais, um programa foi desenvolvido na plataforma Matlab para a identificação das variáveis geométricas dos membros inferiores. Além disso, também foi desenvolvida uma rotina matemática que permitiu calcular, por meio da de decomposição de vetores de força, as cargas que atravessavam cada articulação do joelho. Com estas informações foi possível comparar as variáveis geométricas dos membros inferiores entre os diferentes níveis de OA e também observar por meio de três modelos matemáticos qual a influência destas variáveis no mínimo espaço intra-articular medial (MEIAM), na força no compartimento medial (FCM) e nas estruturas contra-laterais a este compartimento, como o ligamento colateral lateral e trato iliotibial, neste trabalho denominados de força P. Os principais resultados obtidos no presente estudo foram: (1) o desenvolvimento de uma metodologia de calibração de imagens digitais capaz de reduzir os efeitos da ampliação da imagem, corrigindo os valores ampliados aproximando-os dos valores reais; (2) Foi observado que o desalinhamento dos membros inferiores avaliado pelo ângulo que representa a relação entre o quadril, joelho e tornozelo (QJT) tem influência na OA de joelho, assim como o ângulo entre os platôs condilares do fêmur e da tíbia (PC). Visto que quanto maior estes ângulos, menor o mínimo espaço intra - articular medial (MEIAM) e maior os graus de OA. 3) Quando avaliado as variáveis geométricas dos membros inferiores em um teste de regressão linear múltipla, para saber a influência na força do compartimento medial (FCM), na força do ligamento colateral lateral e tracto iliotibial (força P) e no MEIAM, o QJT teve maior poder explicativo tanto para as cargas como o MEIA, confirmando a teoria mecânica. Entretanto o ângulo do colo do fêmur (ACF), apesar de uma baixa participação (6%) que mostrou um grau de importância significativo nos modelos de carga do compartimento e do MEIAM. Assim, embora nós saibamos que os segmentos inferiors ajustam-se mecanicamente em relação a carga, foi observado que o desalinhamento dos membros inferiores é um fator de risco mais importante entre todas as variáveis para o desenvolvimento da OA. / Knee osteoarthritis (OA) is a multifactorial disease that affects people from the third decade of life, but with higher incidence in the elderly. Its classification is based on clinical and qualitative parameters during a medical intervention. In more advanced cases of OA, knee arthroplasty involves not only joint replacement with prosthesis, but also the realignment of the lower limb segments. In this case, there is a need for a more quantitative approach in the pursuit of the joint repositioning in relation to the load bearing axis (LBA). The aim of this study was to develop a methodology that would enable the quantification of a number of structural and functional parameters, using X-ray images, in healthy subjects, asymptomatic for OA and subjects diagnosed with knee OA. This study used the classification adopted by Dejour (1991) to classify the subjects into groups with different degrees of OA. The sample consisted of subjects between 25 and 80 years old, classified with levels 1, 2 and 3 of OA. Besides this classification, subjects were separated by the presence or absence of pain into asymptomatic (OA without pain) and symptomatic (OA with pain). Radiographic images of the lower limb were obtained of the subjects. Prior to obtaining the images, a calibration system was built to identify possible measurement errors and correct them. In addition, the calibration system was also used to define the exact methodology to be used to obtain the images, so that the quantification of structural and functional parameters of each lower limb did not present intervening factors that might mask the results, allowing also the comparison between individuals. After identifying the correction factors of the digital images, a Matlab routine was developed to identify the geometric variables of the lower limbs. In addition, this routine also allowed the calculation, through the decomposition of force vectors, of the loads that cross each knee joint. With this information, it was possible to compare the geometric variables of the lower limbs between different levels of OA and also observe, by means of three mathematical models, the influence of these variables on the medial intra-articular minimum space, on the force in the medial compartment (FMC) and on the contra-lateral structures in this compartment, such as the lateral collateral ligament and the iliotibial tract, called, in this work, P force. The main results of this study were: (1) the development of a calibration methodology for digital images capable of reducing the effects of image magnification, adjusting the values closer to real values; (2) the observation that the misalignment of the lower extremities, evaluated by the angle that represents the relationship between hip, knee and ankle (HKA), has an influence on knee OA, as well as the angle between the condyle plateaus of the femur and the tibia. The larger this angle is, smaller is the medial intra-articular minimum space, and higher are the levels of OA; (3) when evaluating the geometric variables of the lower limbs in a multiple linear regression test, to identify the influence of these variables on the force of the medial compartment (FMC), on the force of the lateral collateral ligament and the iliotibial tract (indicated here as P force) and on the MIAMS it was possible to observe that the HKA showed larger explanatory power for the loads as the MIAMS, confirming the mechanical theory. However, for the angle of the femoral neck (AFN), despite a lower power to explain the dependant variables (only 6%), it still showed a significant importance in the load compartment models and MIAMS. Thus, although we know that the segments adapt or mechanically adjust in response to load, it seems that the lower limb segments alignment is the most important factor amongst all variables as a risk factor for the development of knee OA.
110

Efeito do tipo de revestimento estetico e da eletroerosão sobre a desadaptação de infra-estruturas implanto-suportadas fundidas em titanio c.p. / The influence of the veneering application and Spark erosion on the misfit level of implant-supported frameworks

Nakaoka, Marcia Mika 22 June 2007 (has links)
Orientador: Marcelo Ferraz Mesquita / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T19:46:50Z (GMT). No. of bitstreams: 1 Nakaoka_MarciaMika_D.pdf: 1091285 bytes, checksum: 76d1bd5bef1fb0bee757a9f929be3f3a (MD5) Previous issue date: 2007 / Resumo: As distorções oriundas das técnicas de aplicação de revestimentos estéticos sobre infra-estruturas metálicas de próteses fixas podem resultar em margens cervicais desadaptadas. Dessa forma, este trabalho propôs-se a avaliar o efeito do tipo de revestimento estético, da simulação dos ciclos de cocção da cerâmica, e da aplicação da eletroerosão, sobre o desajuste de infra-estruturas implanto-suportadas fundidas em titânio comercialmente puro (Ti c.p.). Foi utilizada uma matriz metálica contendo 5 pilares intermediários do tipo Microunit. Sobre ela, foram enceradas 40 infra-estruturas, posteriormente fundidas em Ti c.p. (Tritan, Dentaurum, Alemanha). Para cada infraestrutura foi confeccionado um index, com 5 análogos parafusados em cada infra-estrutura. Esse conjunto foi posicionado em microscópio para a mensuração dos desajustes antes da aplicação dos revestimentos estéticos, com a finalidade de avaliar apenas desajuste provocado pela aplicação dos revestimentos estéticos e pelo ciclo de cocção da cerâmica. As infra-estruturas foram separadas, aleatoriamente: G1: resina acrílica ativada termicamente (Clássico, Clássico Artigos Odontológicos Ltda., São Paulo, Brasil); G2: resina fotopolimerizável (Versyo.com, Heraeus Kulzer, Brasil); G3: cerâmica (Triceram, Dentaurum J. P. Winkelstroeter KG ¿ Pforzheim - Alemanha); G4: simulação dos ciclos de cocção da cerâmica. Novamente, após a aplicação dos revestimentos estéticos, foi realizada a avaliação do desajuste marginal sobre o index. Procedeu-se o processo de eletroerosão (Tel Med Technologies, Port Huron, Michigan, EUA). As leituras de desajuste foram realizadas após o aperto com 10 Ncm em um único parafuso, correspondente ao implante A. Através desse procedimento, verificou-se a adaptação dos componentes C e E. O procedimento foi repetido com o outro implante mais distal (E), para mensuração nos implantes A e C. As leituras foram realizadas utilizando microscópio mensurador, com aumento de 120X e precisão de 0,5µm (Micro Vision ¿ Leika, Wetzlar, Alemanha), antes e após aplicação dos revestimentos estéticos, e após o processo de eletroerosão. Os resultados obtidos foram submetidos à Análise de Variância e ao teste de Tukey (p<0,05). Os valores de desajuste marginal das infra-estruturas antes da aplicação dos revestimentos estéticos não apresentaram diferença estatística significante entre si: G1: 29,81 'mu' (+ 10,66); G2: 35,30 'mu' (+ 12,15); G3: 44,75 'mu'(+ 13,73); G4: 38,57 'mu' (+ 16,94). A aplicação dos revestimentos estéticos e a simulação dos ciclos de cocção da cerâmica aumentaram significantemente os valores médios de desajuste marginal para todos os grupos: G1: 221,70 'mu' (+14,11); G2: 81,91 'mu' (+15,71); G3: 233,99 'mu' (+39,18); e G4: 119,75 'mu' (+38,08). Os grupos G1 e G3 não apresentaram diferença estatisticamente significante entre si, mas apresentaram diferença quando comparados aos G2 e G4. Após o processo de eletroerosão, apenas para o grupo G3: 161,16 µm (+36,59 ) a média de desajuste marginal apresentou-se com valor significamente menor. As médias de desajuste marginal para os grupos G1: 198,68 mu' (+34,19); G2: 62,03 'mu' (+17,73) e G4: 87,98 'mu' (+39,32) foram numericamente menores, porém, sem diferença estatística. Como ocorrido anteriormente, os grupos G1 e G3 não apresentaram diferença estatística significante, mas ambos apresentaram diferença quando comparados aos grupos G2 e G4. A partir dos resultados obtidos no presente estudo, conclui-se que os revestimentos estéticos em resina acrílica ativada termicamente e em cerâmica produziram os maiores valores de desajuste marginal para próteses implanto-retidas, enquanto a resina fotopolimerizável, os menores. A aplicação de cerâmica nas infra-estruturas produziu maiores valores de desajuste marginal quando comparado à simples simulação dos ciclos de cocção. O processo de eletroerosão mostrou-se eficaz na redução dos desajustes marginais apenas para o grupo com aplicação da cerâmica / Abstract: The demand for a passive fit of frameworks for osseointegrated endousseous implants abutments is well known, because the tightening of an inaccurate framework to the abutments can transmit stress to the bone-metal interface. The purpose of the present study was to evaluate the influence of the veneering application and porcelain firing cycle on the misfit level of implant-supported frameworks. Forty Ti c.p. (Tritan, Dentaurum, Germany) alloy frameworks were fabricated from a metallic index containing 5 Branemark type multi unit abutments. Analogs of the abutments were positioned to the framework, to construct an index for each framework. This index allowed the observation of the marginal gaps caused by the application of the veneering material. The frameworks were grouped (n=10): 1) heat acrylic resin (Clássico, Clássico, São Paulo, Brazil); 2) light polymerized resin (Versyo.com, Heraeus Kulzer, Brazil); 3) porcelain application (Triceram, Dentaurum - Germany); 4) simulation of porcelain firing cycle. Marginal refinement with spark erosion was conducted on specific equipment (Tel Med Technologies, U.S.A.). The marginal gap was obtained before and after the veneering materials and the spark erosion procedure, following the single screw test protocol (using a tightening force of 10 Ncm). A traveling microscope (STN ¿ Olympus Optical Co. Ltd Japan (120X) was used, tightening 10N in the titanium screw of the extremity distal implant, measuring the gaps at the central and distal implants. Data were subject Analysis of Variance followed by Tukey test (5%). Marginal gap mean values of the frameworks before the veneering application were not significantly different: G1: 29.81 'mu' (+ 10.66); G2: 35.30 'mu' (+ 12.15); G3: 44.75 'mu' (+13.73); G4: 38.57 'mu' (+ 16.94). The application veneering materials and the simulation of porcelain firing cycle increased significantly the misfit mean values of all groups: G1: 221.70 'mu' (+14.11); G2: 81.91 'mu' (+15.71); G3: 233.99 'mu' (+39.18); e G4: 119.75 'mu' (+38.08). There were no significant differences between G1 and G3, but they were significantly different from both G2 and G3. After the spark erosion process, marginal gap mean value decreased significantly only G3 group: 161.16 µm (+36.59). G1: 198.68 'mu' (+34.19); G2: 62.03 'mu' (+17.73) and G4: 87.98 'mu' (+39.32) groups decreased the marginal gap mean values, but not significantly after the spark erosion procedure. As occurred after the application of veneering materials, G1 and G3 groups did not show significant difference, but they both were significantly different from G2 and G4 groups. It can be concluded that heat cured acrylic resin and porcelain produced the highest mean values of marginal gaps, while light cured acrylic resin, the lowest. The application of porcelain produced higher misfit values than the simulation of porcelain firing cycles. After the spark erosion process, marginal gap mean value decreased significantly only porcelain application grou / Doutorado / Protese Dental / Mestre em Clínica Odontológica

Page generated in 0.0852 seconds