• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 139
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 145
  • 60
  • 36
  • 35
  • 31
  • 30
  • 27
  • 24
  • 23
  • 21
  • 19
  • 19
  • 16
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Alterações do tecido mole, espaço faríngeo e estabilidade após avanço maxilo-mandibular xom rotação anti-horária e prótese total de ATM

Pizzol, Karina Eiras Dela Coleta [UNESP] 23 September 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-09-23Bitstream added on 2014-06-13T19:23:12Z : No. of bitstreams: 1 pizzol_kec_dr_arafo.pdf: 688008 bytes, checksum: 35e9164526c1e0e9be53fc6134f7ea9a (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo avaliou a resposta do tecido mole, do espaço faríngeo e a estabilidade após avanço maxilo-mandibular com rotação anti-horária e reconstrução da ATM com próteses totais articulares do tipo TMJ Concepts system®. As mudanças cirúrgicas e pós-cirúrgicas foram analisadas utilizando-se telerradiografias laterais. Com o movimento cirúrgico, houve redução do ângulo do plano oclusal (14,9 ± 8,0°) e aumento do espaço aéreo faríngeo - PASnar (4,9mm). A região anterior da maxila moveu-se para a frente e para cima enquanto a porção posterior, para a frente e para baixo. A mandíbula avançou, e sofreu rotação no sentido anti-horário. No período pós-cirúrgico, a maxila apresentou alterações mínimas no plano horizontal, enquanto todas as medidas mandibulares permaneceram estáveis. A postura da cabeça (OPT/NS) mostrou flexão imediatamente após a cirurgia e extensão em longo prazo, enquanto a curvatura cervical (OPT/CVT) não apresentou mudanças. Os resultados cirúrgicos mostraram ainda aumento das distâncias entre a terceira vértebra cervical (C3) e o mento e desta com o hióide, permanecendo estáveis durante o período de observação. A distância entre o osso hióide e o plano mandibular reduziu durante e após a cirurgia. Já a resposta do tecido mole evidenciou diferentes razões entre tecido duro/mole nos pacientes com e sem genioplastia. As mudanças horizontais na morfologia do lábio superior após avanço, impacção da maxila, sutura em VY e sutura da base alar mostraram maior movimento do que as mudanças observadas em tecido duro. O avanço maxilo-mandibular com rotação anti-horária do plano oclusal associado a próteses totais de ATM (TMJ Concepts system®) mostrou-se estável durante o período de observação. O espaço aéreo faríngeo aumentou... / This study evaluated stability, soft tissue response and oropharyngeal airway space changes after maxillo-mandibular advancement and counter-clockwise rotation with TMJ reconstruction using TMJ Concepts system® total joint prostheses. Lateral cephalograms were analyzed to estimate surgical and post surgical changes. During surgery, the occlusal plane angle decreased 14.9 ± 8.0° and the retroglossal airway space (PASnar) increased 4.9mm. The anterior region of maxilla moved forward and upward while the posterior nasal spine moved downward and forward. The mandible changed forward and rotated in a counter-clockwise direction. At long-term follow-up evaluation the maxilla showed minor horizontal changes, while all mandibular measurements remained stable. Head posture (OPT/NS) showed flexure immediately after surgery and extension long-term post surgery, while cervical curvature (OPT/CVT) had no significant changes. Surgery increased the distances between the third cervical vertebrae (C3) and menton, and C3 and hyoid, remaining stable afterwards. The distance from the hyoid to the mandibular plane decreased during surgery and in the longest follow-up. Soft tissue response indicated different hard/soft tissue ratios between patients with or without genioplasties. Horizontal changes in upper lip morphology after maxillary advancement/impaction, VY closure, and alar base cinch sutures showed greater movement, than observed in hard tissue. TMJ Concepts total joint prostheses associated with maxillo-mandibular advancement and counter-clockwise rotation showed to be stable during the follow-up observation period. Immediate increase in oropharyngeal airway dimension, was influenced by post-surgical changes in head posture but remained stable over the follow-up period. Soft tissue changes showed a known predictable response.
62

Comparação da força de ruptura de alimentos teste entre três diferentes esquemas oclusais para próteses totais

Medeiros, Flávia Regina Machado de [UNESP] 26 July 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-07-26Bitstream added on 2014-06-13T20:25:47Z : No. of bitstreams: 1 000734534.pdf: 2423840 bytes, checksum: 27cd192fc2586553711d9f3f2fdaa7e9 (MD5) / Frente ao reconhecimento de que os movimentos mandibulares são influenciados pela oclusão e, que se pode assumir que o mais efetivo padrão de mastigação para um indivíduo específico irá depender da natureza de sua oclusão, observa-se não existir na literatura correlações concretas entre tipos de oclusões no que diz respeito à função mastigatória. Neste contexto, esse trabalho tem o objetivo de realizar um estudo comparativo laboratorial da força necessária para que ocorra a ruptura de alimentos teste entre os três tipos de esquemas oclusais para próteses totais: Oclusão Convencional, Oclusão Lingualizada e Oclusão Monoplano. Para tanto foi utilizada uma máquina de ensaio universal EMIC a qual se realizou força de compressão sobre um verticulador dotado de dispositivos com os esquemas oclusais em estudo, simulando a força de mordida. A amostra foi formada por três grupos, cada um representando um tipo de oclusão a ser estudada e em cada grupo 5 alimentos teste avaliados, sendo 4 alimentos teste naturais: amêndoa, amendoim, cenoura e café e um alimento teste artificial representado pela silicone (optosil). As oclusões formadas por dentes anatômicos (convencional e lingualizada) tiveram maior desempenho, precisando assim de uma força de mordida menor para realizar a ruptura do alimento teste em relação a oclusão com dentes não anatômicos (monoplano). Houve diferença estatística na maioria das comparações entre os esquemas oclusais estudados em relação à força necessária para causar ruptura dos alimentos-teste, mas nenhum esquema em particular foi melhor do que os outros para todos os tipos de alimento teste. / Three popular occlusal schemes for complete dentures are: conventional balanced occlusion; lingualized balanced occlusion and monoplane occlusion. It was observed that there is few scientific data that allow effective correlation related to the masticatory function between the cited occlusion schemes. In this context, the purpose of this study is to describe a laboratory comparative study of the occlusal force necessary to cause rupture in certain test foods between the conventional, lingualized and monoplane occlusal schemes used to construct complete dentures. The occlusal force was generated by an EMIC universal tests machine compressing the upper side of an articulator where occlusal patterns resembles representing the studied occlusal schemes were fixed. Five different test foods were used in this research, four out five were natural foods (almond, peanut, coffee and carrot) and one was artificial (silicone). It was concluded that: 1. In most comparisons, there were significant statistical differences in the forces applied by the studied occlusal schemes to cause rupture of the test foods, but there was no particular scheme better than the others; 2. In most comparisons the monoplane scheme of occlusion required higher forces to cause the rupture of the test foods.
63

Efeito de elementos substitucionais e intersticiais na microestrutura, dureza e módulo de elasticidade de ligas Ti-Nb

Silva, Luciano Monteiro da [UNESP] 14 April 2014 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:42Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-04-14Bitstream added on 2014-12-02T11:20:59Z : No. of bitstreams: 1 000799348.pdf: 6754619 bytes, checksum: e644afc59cd5041af19277598bbc1e58 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Os recentes avanços científicos resultaram em melhor qualidade de vida e consequente aumento da longevidade. Por conta disso, a população de idosos aumentou e doenças relacionadas à idade como osteoporose levam o governo a ter que gastar consideráveis quantias em próteses ortopédicas. Há também uma grande demanda devido aos acidentes de transito. A liga de Ti mais utilizada para aplicações biológicas é a liga Ti-6Al-4V, porém alguns estudos associam efeitos citotolóxicos e reações adversas em tecidos e desordens neurológicas à presença de Al e V. Para sanar este problema, novas ligas de Ti que apresentam em sua composição elementos como Nb, Ta, Zr, Fe e Mo estão sendo pesquisadas e o desenvolvimento de novas ligas de Ti contendo Nb para aplicação ortopédica é um tema de grande importância social e tecnológica, pois o Nb é um elemento não tóxico e não alergênico, possui elevada biocompatibilidade e tem o Brasil como seu maior produtor, daí a importância de desenvolvimento de ciência e tecnologia utilizando tal maneira. As etapas de processamento, a concentração de soluto substancial e a presença de elementos interticiais (O, C, N e H) alteram significativamente as propriedades mecânicas da liga, principalmente suas propriedades elásticas, causando endurecimento ou enfraquecimento da liga. Este trabalho apresenta os efeitos das etapas de processamento, da concentração de nióbio e de oxigênio intersticial em solução sólida na dureza, módulo de elasticidade e microestrutura de ligas do sistema Ti-Nb, preparadas por fusão a arco e caracterizadas por medidas de densidade, difração de raios X, microscopia eletrônica de varredura, microdureza Vickers, análise química quantitativa, análise do teor de oxigênio e módulo de elasticidade. Observa-se tendência de aumento da dureza e do módulo de elasticidade com o aumento do teor de oxigênio, enquanto o aumento do teor de nióbio tende a diminuir... / Recent scientific advances have led to a significant increase in life's quality and consequantly, longevity. As a result, the elderly population has increased considerably and thus age-related diseases such as osteoporosis lead the government to spend considerable sums of money with orthopedic prostheses. There is also a great demand for orthopedic prostheses due to accidents. The most used Ti-based alloy for biological applications is the Ti-6Al-4V alloy, but some studies associate the V to cytotoxic effects and adverse reactions in tissues , while Al has been associated with neurological disorders. To solve this problem, new Ti-based alloys that have in their composition elements such as Nb, Ta, Zr, Fe and Mo are being researched. The development of new Ti-based alloys containing Nb for orthopedic application is a topic of great social and technological relevance, as this element is a non-toxic, non-allergenic, has high biocompatibility and has Brazil as its biggest producer, hence the importance of development of science and technology using this material. The processing steps, the concentration of substitutional solute and the presence of interstitial elements (O, C, N and H) changes signficantly the mechanical properties of the alloy, particularly its elastic properties, causing hardening or softening of the alloy. This work presents the effects of processing steps, the concentration of interstitial oxygen and niobium in solid solution in some mechanical properties of alloys of Ti-NB system, prepared by arc melting and characterized by density measurements, X-ray diffraction, optical microscopy, Scanning Electron Microscopes, microhardness, quantitative chemical analysis, analysis of the oxygen content and modulus of elasticity. Observed trend of increasing oxygen content, while increasing in the niobium content tends to stabilize the B phase, which presents values lower of elasticity modulus than the presented by the a phase / FAPESP: 09/16731-9
64

Planejamento protético para pacientes adultos portadores de fissura labiopalatal congênita, que não obtiveram oportunidade de um tratamento reabilitador ideal: execução de casos clínicos para pacientes selecionados

Figueiredo, Aldari Raimundo [UNESP] 24 September 1992 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:24Z (GMT). No. of bitstreams: 0 Previous issue date: 1992-09-24Bitstream added on 2015-01-26T13:30:31Z : No. of bitstreams: 1 000024127.pdf: 3905448 bytes, checksum: 05963652393e1ca7e3f6c0c85b00a99b (MD5) / Embora não se possa prevenir o nascimento de indivíduos fissurados, podemos adotar atitudes e procedimentos vários, plenamente viáveis dentro de um complexo hospitalar-médico-odonto-psico-fono-pedagógico-social para tratamento, reabilitação e recuperação destas pessoas. Visando minorar o sofrimento destes pacientes, é que desenvolvemos este trabalho para provar que, senão de uma maneira “ideal”, mas bastante aceitável, podemos reintegrar estes indivíduos ao convívio de seus familiares e amigos, oferecendo-lhes mais segurança nos seus relacionamentos social, psíquico e humano. Fizemos um levantamento na literatura especializada nas últimas três décadas; encontramos inúmeras possibilidades de recuperação protética, no que concerne à estética, à mastigação e ao relacionamento maxilomandibular, além de permitir a esses pacientes condições de realizarem satisfatoriamente as funções da deglutinação e fala. Selecionamos e executamos cinco casos clínicos em uma mostragem de quinze pacientes previamente triados, procurando uma diversificação nos planejamentos protéticos. Mostramos ainda a enorme contribuição que os implantes osteointegrados podem oferecer na reabilitação e recuperação de pacientes com lesão labiopalatal congênita. Para facilitar o entendimento procuramos discutir os mais variados tipos de próteses em tópicos distintos, abordando cada uma delas isoladamente; mostrando que a especificidade de cada caso condiciona a uma conduta reabilitadora específica e individualizada, embasada em conceitos de estética, oclusão, suporte ósseo, espaço protético, retenção e, acima de tudo, do bom sendo e da honestidade profissional / Although one cannot prevent the birth of human beings with cleft palate lesions one can adopt attitudes and various procedures entirely viable to rehabilitate and recuperate these persons through a team work composed of the facilities of a hospital, physician, dentist, psychotherapist, epeech pathologist, pedagogue and a social worker. In order to reduce the suffering of these patients we took up this work to prove that even if not in an ideal manner nevertheleses in an acceptable one we can reintegrate these persons to their families, friends and social milieu, offering them more security in their social, psychic and human relationships. We have made a review of the literature during the last three decades where we found many possibilities of prosthetic recuperations which concerns esthetics, mastication and maxillomandibular relationships beyond allowing these pacients conditions to perform satisfactory the functions of deglution and speech. We have selected and executed 5 clinical cases out of 15 pacients formely choosen looking to different prosthetic plannings. We have also shown the major contribution that the osseous integrated implants can offer to the rehabilitation and recuperation of pacients whith congenitall labio palatal lesions. To simplify the understanding we tried to discuss the most varied types of prosthesis in well defined subjects having a separate approach for each of them and we still showed that the specificity of each case leads to a specific type of rehabilitation founded om esthetics, occlusion, osseous suport, edentulous space, and above all based in the common sense and Professional integrity
65

Estudo clínico de prevalência de sinais e sintomas de disfunções craniomandibulares e contatos oclusais cêntricos em pacientes portadores de lesão labiopalatal

Silva, Regina Célia Santos Pinto [UNESP] 24 September 1992 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:24Z (GMT). No. of bitstreams: 0 Previous issue date: 1992-09-24Bitstream added on 2015-01-26T13:30:31Z : No. of bitstreams: 1 000024656.pdf: 1495405 bytes, checksum: 564f831ac9396905debbc6230f9e3d95 (MD5) / Foi realizado um estudo em onze pacientes portadores de lesão labiopalatal, quanto a prevalência de sinais e sintomas de disfunções craniomandibulares, associada ao número e distribuição dos contatos oclusais cêntricos, através de questionário, exame clínico e exame dos modelos dos pacientes montados em articulador semi-ajustável, em posição de máxima intercuspidação. Com relação aos sinais e sintomas, os mais frequentes foram ruído articular e sensibilidade à palpação do músculo lateral, seguidos por limitação de abertura e sensação de cansaço. Quanto aos contatos oclusais, o número foi muito reduzido (cerca de 5 contatos por pacientes, em média) e a localização foi considerada atípica pois em 62% dos casos o contato ocorreu em plano inclinado, o que sugere instabilidade oclusal. Foi baixa a frequência dos sinais e sintomas encontrados e todos considerados suaves. Os três sinais mais comuns de disfunções craníomandibulares (ruído articular, sensibilidade muscular à palpação e limitação de abertura) estavam presentes em apenas um dos casos / A clinical investigation was undertaken to find out the prevalence of craniomandibular signs and symptoms in a group of 11 patients with labiopalatal lesions. The number and distribution of occlusal contacts was evaluated through questionnaire, clinical examination and analysis of mounted casts in partially adjustable articulators in the position of maximum inter cuspation. The most frequent signs and symptoms were articular sounds and lateral pterygoid muscle tenderness to palpation followed by restriction of mouth opening and sensation of tiredness. The number of occlusal contacts was small, mean of 5 contacts per patient, and the site was considered as atypical, 62% of them were on inclined plane surfaces , suggesting occlusal instability. The frequency of signs and symptoms was low and they were of a mild character. The most prevailing signs of craniomandibular dysfunction - articular sounds, muscular tenderness to palpation and restriction of mouth opening - was noticed in only one of the patients
66

Estudo in vitro do comportamento de facetas confeccionadas com artglass e targis quando submetidas à inserção e remoção de grampos circunferenciais em cromo-cobalto

Marchini, Leonardo [UNESP] 15 June 2000 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2000-06-15Bitstream added on 2015-01-26T13:30:29Z : No. of bitstreams: 1 000126044.pdf: 2751052 bytes, checksum: bf32f58800e85b85750a1a62a30b710d (MD5) / Tendo por objetivo investigar in vitro o comportamento das facetas estéticas confeccionadas com as resinas laboratoriais Artglass e Targis, colocadas em coroas veneer, quando submetidas à inserção e remoção de grampos circunferenciais de cromo-cobalto, foram confeccionadas 24 coroas veneer, sendo doze com faceta estética de Artglass (Heraeus Kulzer) e doze de Targis (Ivoclar Vivadent) e os respectivos grampos de cromo-cobalto. As coroas foram então submetidas a cinco mil ciclos de inserção e remoção dos grampos, em dispositivo destinado para tal. Mediante a aferição da força necessária para a remoção dos grampos das coroas durante os ensaios, da variação da massa dos grampos e coroas e da verificação macroscópica das facetas, foi possível concluir que as facetas estéticas não apresentam variação significativa na força necessária para a remoção dos grampos; apresentam pequena abrasão, observável por inspeção visual e apresentam pequena e variável perda de massa, menor para aquelas confeccionada em Artglass (0,002g em média) e maior para aquelas confeccionadas em Targis (0,006g em média) / Aiming to investigate in vitro the behavior of esthetic veneers placed in crows and made of the laboratory resins Artglass and Targis when submitted to insertion and removal of circunferential cobalt-chromium clasps, 24 veneer crowns were made (twelve with Artglass (Heraeus Kulzer) and twelve with Targis (Ivoclar Vivadent)), as well as the respective cobalt-chromium clasps. The crowns were then submitted to five thousand cycles of clasps insertion and removal, using a proper device. Using the verification of the force necessary to remove the clasps over the crowns during the experiment, the clasps and crowns mass variation, and the macroscopic inspection of the veneers, one may conclude that the veneers did not show a significant variation of the force required to remove the clasps over the crowns; they show a little amount of abrasion, possible to detect using a visual inspection and they show a little and variable amount of mass loss, less for that made with Artglass (average of 0,002g) and greater for that made with Targis (average of 0,006g)
67

Análise morfométrica da parede arterial após o implante de stent em aorta abdominal de suínos : estudo comparativo entre stents metálicos não recobertos e recobertos com politetrafluoroetileno / Morphometric analysis of the arterial wall after stent deployment in the pig aorta : comparative study between naked and PTFE covered stainless steel stents

Grudtner, Marco Aurelio January 2001 (has links)
O espessamento intimal e a reestenose que ocorrem após os procedimentos de angioplastia transluminal percutânea e/ou o implante de stents representam uma causa freqüente de falência destes procedimentos. O principal achado patológico responsável pela reestenose parece ser a hiperplasia intimal, já que o dispositivo intravascular é resistente ao remodelamento arterial geométrico. O propósito deste estudo é avaliar, através da morfometria digital, o espessamento intimal presente nas regiões da parede arterial imediatamente proximal e distal ao implante de um stent metálico em configuração em “Z “ não recoberto ou recoberto com PTFE. Vinte e cinco suínos de raça mista, com seis a dez semanas de idade, pesando em média 20 kg foram divididos em três grupos. No grupo I, cinco animais foram submetidos à exposição cirúrgica retroperitoneal da aorta abdominal, aortotomia e manipulação com uma bainha introdutora de 12 F. O grupo II incluiu dez animais que foram submetidos ao implante de um stent metálico auto-expansível não recoberto. No grupo III, incluindo também dez animais, foram implantados stents recobertos com PTFE. Após quatro semanas, todos os animais foram sacrificados e o segmento aorto-ilíaco foi removido. Quatro animais foram excluídos do estudo por trombose da aorta (um animal do grupo II e três animais do grupo III). Para a análise morfométrica foram utilizados os testes não paramétricos de Wilcoxon e de Kruskal-Wallis, para as comparações, respectivamente, no mesmo grupo e entre os grupos. Foi adotado o nível de significância de 5% ( p< 0,05). Quando os espécimes da parede arterial, imediatamente proximal e distal aos stents foram comparados, nenhuma diferença estatisticamente significativa foi encontrada entre as áreas luminal, intimal, média ou índice intimal em cada grupo. Na comparação entre os grupos, as áreas intimal, média e o índice intimal não demonstraram variação estatisticamente significativa. Foram identificadas diferenças entre os grupos quanto às áreas luminais proximais (p = 0,036) e distais (p=0,044). Pelo teste de comparações múltiplas para Kruskal-Wallis (Teste de Dunn) identificou-se diferença significativa entre os grupos I e II. Entretanto, quando estas variáveis foram controladas pelo fator peso (relação área luminal/peso) a diferença não foi mais observada. Concluímos que, após quatro semanas, stents recobertos com PTFE induzem um espessamento intimal justa-stent similar ao observado com stents não recobertos ou com a simples manipulação arterial com uma bainha introdutora. Neste modelo experimental suíno, de curto seguimento, o revestimento com PTFE não foi responsável por adicional espessamento intimal. / Intimal thickening and restenosis occurring after angioplasty and/or stent deployment constitutes a frequent determinant of failure of these procedures. The main pathologic finding responsible for restenosis seems to be intimal hyperplasia, since the intravascular device is resistant to geometric arterial wall remodeling. The purpose of this study is to evaluate, by means of digital morphometry, the intimal thickening present in the regions of the arterial wall proximal and distal to the implant of a naked or PTFE covered stainless steel Z stent. Twenty five crossbred pigs, 6 to 10 weeks old, weighing between 14 and 32 kg (average= 20 kg) kg were divided in three groups. Group I included five animals that were submitted to retroperitoneal exposure of the aorta, aortotomy and simple insertion of a 12 F sheath. Group II included those animals in which a naked stent was deployed. Finally, in group III included the use of a PTFE covered stent. After four weeks, all animals were submitted to euthanasia and the aorto-iliac segment was removed. Four animals were excluded from the study due to aortic thrombosis (one from group II and three from group III). Morphometric analysis was performed using the non-parametric Wilcoxon and Kruskal-Wallis tests to compare data within the group, and across groups, respectively. When specimens of the arterial wall immediately proximal and distal to the stents were compared, no statistically significant difference could be established regarding luminal, intimal and media areas or intimal index. It was not possible to find significant differences between the intimal and medial areas or the intimal index. According to the Kruskal-Wallis test, a significant difference between proximal (p=0,036) and distal (p=0,044) luminal areas was observed between groups. The Dunn test identified differences between groups I and II. However, when these variables were corrected regarding the weight factor (luminal area/ weight index) this difference was no longer seen. We conclude that, after four weeks, covered PTFE stents generate an intimal thickening similar to uncovered stents or simple catheter manipulation. In this experimental model, the PTFE material was not responsible for additional intimal thickening during this limited period of time.
68

Implante de cimento de alfa-fosfato tricálcico de dupla pega munido de canais de interconexão em órbita de coelhos

Gomes Junior, Deusdete Conceição [UNESP] 18 December 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:41Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-12-18Bitstream added on 2014-06-13T19:30:07Z : No. of bitstreams: 1 gomesjunior_dc_me_jabo.pdf: 624070 bytes, checksum: a517292c6e1d8ca2eedd629c534840fb (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Os implantes oculares são empregados após a remoção do bulbo do olho ou seu conteúdo, visando a manutenção do volume orbitário e a posterior colocação de prótese ocular. Estes são classificados como integráveis ou não integráveis, quando permitem ou não a infiltração de tecido fibrovascular do hospedeiro, respectivamente. Considerando a cirurgia protética como procedimento de relevância na oftalmologia veterinária e humana, buscou-se com a pesquisa avaliar macroscopicamente e por microscopia eletrônica de varredura as esferas do cimento de -fosfato tricálcico de dupla pega munido de canais de interconexão, assim como a integração do implante com o tecido orbital de coelhos, por meio de análise macroscópica e histopatológica. Doze animais compuseram o grupo experimental, sendo submetidos a enucleação do olho esquerdo e inserção do implante. Os períodos de avaliação foram 15, 45, 90 e 180 dias de pós-operatório, com exenteração da órbita de três animais, por período, para análise histopatológica. A microarquitetura das esferas caracterizou-se pela formação de colunas de cristais hexagonais e microporos medindo de 1,3-5,5 m e 0,5-5,6 m, respectivamente. Na avaliação histopatológica observou-se presença de fina cápsula ao redor do implante, de onde surgiram projeções fibrovasculares que o penetraram através dos canais de interconexão. Inicialmente foi constatada intensa reação inflamatória, com predomínio linfo-histiocitário, que diminuiu gradativamente ao longo do período de avaliação e foi ausente aos 180 dias. O implante mostrou-se biocompatível e integrável uma vez que os orifícios permitiram a penetração de tecido fibrovascular / Ocular implants are employed after the removal of the eye or its internal content, aiming at maintaining the volume of orbit and the subsequent placing of ocular prosthesis. These are classified as integrable or not integrable, when enable or not the tissue infiltration fibrovascular stroma of the host, respectively. Considering the prosthetic surgery procedure of veterinary and human relevance in ophthalmology, sought with the research evaluate macroscopically and by scanning electron microscopy spheres of double-setting -tricalcium phosphate cement provided with interconnection channels, as well as the integration of the implant to the tissue orbital of rabbits, through macroscopic and histopathological analysis. Twelve animals composed the experimental group, being subjected to enucleation of the left eye and implant insertion. The evaluation periods are 15, 45, 90 and 180 days postoperatively, orbital exenteration with three animals, per period, for histopathological analysis. The microarchitecture of the spheres characterized by the formation of columns of hexagonal crystals and micropores measuring 1,3-5,5 m and 0,5-5,6 m, respectively. The histopathological evaluation revealed the presence of thin capsule around the implant, where arose the beams penetrated through the channels of interconnection. Intense inflammatory reaction initially was established, with a predominance lymphohistiocytic which decreased gradually over the period of evaluation and was out to 180 days. The implant proved to be biocompatible and integrable since the holes allowed the tissue penetration fibrovascular stroma
69

Avaliação da proporção áurea em radiografias cefalométricas laterais de indivíduos edêntulos antes e depois do tratamento por próteses totais

Costa, Carolina Bacci [UNESP] 07 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-07Bitstream added on 2014-06-13T19:58:59Z : No. of bitstreams: 1 costa_cb_me_sjc.pdf: 9115863 bytes, checksum: b55692040c6c0db904941ff84b33fc33 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O propósito neste estudo foi avaliar razões para verificação da proporção áurea entre estruturas ósseas do crânio e face de indivíduos edêntulos, antes e depois do tratamento por próteses totais. Foram utilizadas 60 radiografias cefalométricas laterais de 30 indivíduos desdentados totais bimaxilares, tratados na Disciplina de Prótese Total da Faculdade de Odontologia de São José dos Campos - UNESP. A técnica radiográfica foi realizada em um único aparelho, pelo mesmo operador, sendo: a primeira radiografia sem as próteses em posição de repouso fisiológico e a segunda com as próteses totais em oclusão cêntrica. As radiografias foram digitalizadas e com o auxílio do programa de computador Radiocef Studio 2 (Radiomemory, Belo Horizonte, Brasil), foi possível criar uma nova análise cefalométrica para a marcação dos pontos cefalométricos e obtenção dos fatores envolvidos nas razões avaliadas. A marcação dos pontos foi realizada em dois tempos, num intervalo de 30 dias, a fim de avaliar o erro intra-examinador. Após análise estatística por meio do teste t de Student e t pareado, comparando-as ao número áureo 1,618, as razões Or-Me/Co-Go, Pog- Op/Or-Me e Pog-Op/Enp-Op não diferiram estatisticamente antes e depois do tratamento protético. As razões Or-Me/Ena-Enp, Or-Me/N-Ena, Or-Me/Op-N e NMe/ Ena-Me diferiram estatisticamente, sendo a última de forma favorável, ou seja, aproximou-se ao número áureo após o tratamento por próteses totais. / The aim of this study was to evaluate ratios in edentulous subjects, between bone structures of the skull and face, before and after prosthetic treatment with complete dentures. Sixty cefalometric x-rays from 30 edentulous subjects were used and all the complete dentures were made by School of Dentistry`s students, from São Paulo State University. The radiographs were taken by only one examiner, in the same x-ray unit. The radiographs were: the first without the complete dentures, in mandibular rest position, and the second, in centric occlusion. The analysis cephalometrics were performed using the software Radiocef Studio 2 (Radiomemory, Brazil). In order to evaluate error intraexaminer, the cephalometric points were marked in two times in each radiograph. The means of each ratio were statistically analysed by paired t-test and Student`s t-test, and compared with the golden number 1,618. There were no statistically significant in ratios Or-Me/Co-Go, Pog-Op/Or-Me and Pog- Op/Enp-Op, before and after prosthetic treatment. The ratios Or-Me/Ena- Enp, Or-Me/N-Ena, Or-Me/Op-N and N-Me/Ena-Me were different statistically. The ratio N-Me/Ena-Me was closer than the golden number, after prosthetic treatment with complete dentures.
70

Estudo "in vitro" do comportamento de facetas confeccionadas com artglass e targis quando submetidas à inserção e remoção de grampos circunferenciais em cromo-cobalto /

Marchini, Leonardo. January 2000 (has links)
Orientador: José Eduardo Junho de Araújo / Banca: Cícero Eleutério da Silva Filho / Banca: Maria Amélia Maximo de Araujo / Resumo: Tendo por objetivo investigar in vitro o comportamento das facetas estéticas confeccionadas com as resinas laboratoriais Artglass e Targis, colocadas em coroas veneer, quando submetidas à inserção e remoção de grampos circunferenciais de cromo-cobalto, foram confeccionadas 24 coroas veneer, sendo doze com faceta estética de Artglass (Heraeus Kulzer) e doze de Targis (Ivoclar Vivadent) e os respectivos grampos de cromo-cobalto. As coroas foram então submetidas a cinco mil ciclos de inserção e remoção dos grampos, em dispositivo destinado para tal. Mediante a aferição da força necessária para a remoção dos grampos das coroas durante os ensaios, da variação da massa dos grampos e coroas e da verificação macroscópica das facetas, foi possível concluir que as facetas estéticas não apresentam variação significativa na força necessária para a remoção dos grampos; apresentam pequena abrasão, observável por inspeção visual e apresentam pequena e variável perda de massa, menor para aquelas confeccionada em Artglass (0,002g em média) e maior para aquelas confeccionadas em Targis (0,006g em média) / Abstract: Aiming to investigate in vitro the behavior of esthetic veneers placed in crows and made of the laboratory resins Artglass and Targis when submitted to insertion and removal of circunferential cobalt-chromium clasps, 24 veneer crowns were made (twelve with Artglass (Heraeus Kulzer) and twelve with Targis (Ivoclar Vivadent)), as well as the respective cobalt-chromium clasps. The crowns were then submitted to five thousand cycles of clasps insertion and removal, using a proper device. Using the verification of the force necessary to remove the clasps over the crowns during the experiment, the clasps and crowns mass variation, and the macroscopic inspection of the veneers, one may conclude that the veneers did not show a significant variation of the force required to remove the clasps over the crowns; they show a little amount of abrasion, possible to detect using a visual inspection and they show a little and variable amount of mass loss, less for that made with Artglass (average of 0,002g) and greater for that made with Targis (average of 0,006g) / Mestre

Page generated in 0.0543 seconds