• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 139
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 145
  • 60
  • 36
  • 35
  • 31
  • 30
  • 27
  • 24
  • 23
  • 21
  • 19
  • 19
  • 16
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Resistência de união e limite de fadiga de nichos confeccionados em resina composta e cimentos à base de ionômero de vidro

Lopes, José Fernando Scarelli [UNESP] 17 February 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-02-17Bitstream added on 2014-06-13T18:58:07Z : No. of bitstreams: 1 lopes_jfs_me_arafo.pdf: 1497511 bytes, checksum: 5cff0da20eacc454b65a7066c2aba9f6 (MD5) / O objetivo desta investigação foi determinar a resistência de união e limite de fadiga de nichos confeccionados em resina composta e ionômeros de vidro. Setenta e cinco corpos-de-prova (incisivos mandibulares humanos hígidos) com etiquetas adesivas com perfurações de 3,5mm de diâmetro foram adaptadas sobre a superfície lingual de cada dente. Esta delimitação tinha como objetivo padronizar a área da superfície de esmalte a ser condicionada e, posteriormente, mantida em contato com os materiais restauradores. Para realização dos nichos, matrizes foram realizadas para cada corpo-de-prova onde o material restaurador foi inserido. Os corpos-de-prova foram imersos em água destilada a 37ºC por um período de 30 dias. Para os ensaios de resistência à união, a máquina de testes mecânicos MTS modelo 810 foi calibrada utilizando uma velocidade de deslocamento de 0,5mm/min. Para os testes de limite de fadiga a máquina de testes foi calibrada para submeter cada corpo-de-prova a 10.000 ciclos constantes, com uma freqüência de 5 Hz, amplitude inicial de 0,5 mm e velocidade de rampa inicial de 100N/s. Os valores originais do experimento foram convertidos de N para MPa em função da área da base do nicho (circular) previamente calculada. Os corpos-de-prova após a fratura foram avaliados através de microscopia eletrônica de varredura com aumento de 500 vezes. A médias de resistência à união e limite de fadiga foram comparadas estatisticamente usando o teste de Análise de Variância a um Critério. Nos teste de cisalhamento, a resina composta Z-100 produziu maior valor de resistência de união (12,25 MPa) ao esmalte dentário que o ionômero de vidro convencional Fuji IX (7,21MPa). Não foram observadas diferenças entre os valores do material Fuji II LC (10,29MPa) e os demais materiais. Para todos os materiais, os corpos-de-prova testados por meio de ensaio dinâmico de... / The aim of this study was to determine the bond strength and fatigue limit of rest seats prepared with composite resin and glass ionomer cements. The lingual aspect of seventy-five specimens (intact human mandibular incisors) was delimited by adhesive tags with 3.5-mm diameter perforations. This delimitation aimed at standardizing the area of enamel surface to be etched and later kept in contact with the restorative materials. For preparation of the rest seats, matrixes were obtained for each specimen on which the restorative material was placed. The specimens were immersed in distilled water at 37ºC for a period of 30 days. For the bond strength assays, the mechanical assay machine MTS model 810 was calibrated at a displacement speed of 0.5mm/min. For the fatigue limit tests, the assay machine was calibrated so as to submit each specimen to 10,000 constant cycles, at a 5-Hz frequency with an initial range of 0.5mm and initial sloping speed of 100N/s. The original values of the experiment were converted from N to MPa according to the previously calculated circular area of the base of the rest seat. After fracture, the specimens were evaluated by means of scanning electron microscopy with magnification of 500x. The means of bond strength and fatigue limits were statistically compared through the one-way variance analysis. For the shear resistance test, the composite resin Z-100 yielded a higher value of bond strength (12.25 MPa) to the dental enamel than the conventional glass ionomer cement Fuji IX (7.21MPa). No differences could be found between Fuji II LC (10.29MPa) and the further materials. For all materials, the specimens submitted to dynamic fatigue assay tests yielded lower mean values than those achieved through static shear assays. Regarding the fatigue limit values, all materials presented different behaviors, being that Fuji II LC obtained the higher mean value (6.4MPa), ...(Complete abstract, click electronic access below)
82

Influência da desinfecção química e do tempo de armazenagem sobre as propriedades físicas das próteses oculares

Moreno, Amália [UNESP] 04 February 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-02-04Bitstream added on 2014-06-13T20:58:50Z : No. of bitstreams: 1 moreno_a_me_araca.pdf: 1094331 bytes, checksum: 23ef0f4dabc4bc9f560778bae7c35338 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / As próteses oculares são responsáveis pela recuperação da estética e auto-estima do usuário. Assim, os materiais utilizados na confecção de prótese ocular devem possuir propriedades específicas para sua indicação e durabilidade. Desse modo, é importante avaliar o comportamento destes materiais quando influenciados por diversas soluções desinfetantes. Este estudo teve como objetivo avaliar a microdureza, rugosidade superficial e alteração de cor de próteses oculares sobre a influência da desinfecção química e armazenagem. Foram confeccionadas 50 amostras simulando próteses oculares contendo duas resinas acrílicas (N1 e incolor), distribuídas em cinco grupos de acordo com o desinfetante utilizado: sabão neutro (I), opti-free (II), efferdent (III), hipoclorito a 1% (IV) e clorexidina a 4% (V). As amostras foram armazenadas por 120 dias, sendo desinfetadas durante este período. As leituras de microdureza, rugosidade e cor das amostras foram realizadas em um período inicial (B) e após 60 (T1) e 120 (T2) dias de armazenagem com desinfecção. A microdureza foi mensurada por meio de um microdurômetro, e a rugosidade determinada por um rugosímetro. A leitura de cor foi realizada por meio da espectrofotometria de reflexão, usando o sistema CIE L*a*b*. A alteração de cor (ΔE) foi calculada para os períodos entre T1 e B (T1B), e T2 e B (T2B). Pelos resultados obtidos a resina N1 para esclera apresentou menor microdureza estatisticamente significante, comparada a resina incolor (P<0,05). A maior alteração dos valores de microdureza e rugosidade foi obtida para os grupos IV e V. Ambos os períodos de desinfecção e armazenagem produziram alterações significativas (P<0,05) nas amostras com diminuição dos valores de... / Ocular prostheses are responsible to restore not only patient’s aesthetic but also its self-esteem. The materials used to fabricate the ocular prostheses should present specific properties regarding its indication and durability. Therefore, it is important to investigate the physical behavior of such materials when subjected to different disinfectant solutions. This study evaluated the microhardness, surface roughness and color stability of ocular prostheses under the influence of different chemical disinfectant solutions and storage. A total of 50 samples simulating an ocular prosthesis containing two acrylic resins (N1 and colorless) were fabricated. They were divided into five groups as a function of disinfectant solution: neutral soap (I), opti-free (II), efferdent (III), 1% hypochlorite (IV) and 4% chlorhexidine (V). Samples were storage during 120 days, and they were disinfected throughout the period. Microhardness, roughness and color measurements were performed at baseline (B), after 60 (T1) and 120 (T2) days of storage with disinfection. The microharness and the roughness measurements were evaluated using a microdurometer and a roughness meter, respectively. Samples colors were measured with spectrophotometer using CIE L*a*b* system. Color differences (ΔE*) were calculated for periods between T1 and B (T1B), and T2 and B (T2B). The N1 acrylic resin exhibited statistically lower microhardness when compared to the colorless acrylic resin (P<0.05). The highest microhardness and roughness alterations were observed for groups IV and V. Both disinfection and storage periods statistically reduced the microhadness values and increased the roughness values of the samples (P<0.05). Color alteration was... (Complete abstract click electronic access below)
83

Efeito da desinfecção química e do envelhecimento acelerado sobre a estabilidade dimensional, reprodução e manutenção de detalhes e estabilidade de cor do silicone facial Silastic MDX 4-4210 com opacificador

Haddad, Marcela Filié [UNESP] 03 March 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-03-03Bitstream added on 2014-06-13T20:37:55Z : No. of bitstreams: 1 haddad_mf_me_araca.pdf: 2948188 bytes, checksum: 2fbab93d0b5d242f0543ea496a3c8a05 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este estudo teve como objetivo avaliar a estabilidade dimensional, reprodução de detalhes e estabilidade de cor de silicone facial, com adição ou não de pigmento e opacificador; sob influência da desinfecção química e do envelhecimento acelerado. Para isso, foram obtidas 120 amostras, utilizando o silicone Silastic MDX 4-4210, divididas em 4 grupos contendo 30 amostras cada, sendo GI - incolor, GII - pigmentado com pó de cerâmica, GIII – com adição de sulfato de bário (opacificador) e GIV- pigmentado com pó de cerâmica e sulfato de bário. Dez amostras de cada grupo foram desinfetadas com uma das três substâncias a seguir: pastilhas efervescentes a base de peróxido alcalino, sabão neutro ou clorexidina. O processo de desinfecção química foi realizado três vezes por semana, durante 60 dias. Após esse período, todas as amostras foram submetidas ao envelhecimento acelerado. Os testes de estabilidade dimensional, reprodução de detalhes e estabilidade de cor foram realizados no período inicial, após 60 dias de desinfecção e, nos intervalos de 252, 504 e 1008 horas de envelhecimento acelerado. As amostras foram analisadas em computador pelo sistema AutoCAD para verificação da alteração dimensional linear; e observadas em lupa estereoscópica para a análise da reprodução de detalhes. A estabilidade de cor foi verificada por meio de espectrofotometria de reflexão. Os valores obtidos nos testes de estabilidade dimensional e estabilidade cromática foram submetidos à análise de variância e teste de Tukey (p<0,05). Para a análise da reprodução e manutenção de detalhes foi utilizado escore de 0 a 2. O fator desinfecção não influenciou estatisticamente nos valores de estabilidade dimensional, reprodução de detalhes e estabilidade de cor do silicone, independente da... / The aim of this study was to evaluate the dimensional stability, reproduction and maintenance of details and color stability of facial silicone, with different pigmentation, on the influence of the disinfection and accelerated aging. 120 samples were obtained, using Silastic MDX 4-4210 elastomer, divided in 4 groups with 30 samples: GI - colorless, GII - pigmented with ceramics, GIII - pigmented with barium sulfate opacifier, and GIV - pigmented with ceramics and barium sulfate opacifier. Ten samples of each group was submitted to the disinfection with effervescent tablets, with neutral soap or 4% chlorhexidine, three times a week during 60 days. After this period all samples were taken to a chamber of accelerated aging for not metallic bodies. The tests of dimensional stability, maintenance of the details, and color stability were realized after the confection, disinfection and in the intervals of each cycle of accelerated aging (252, 504 e 1008 hours). Samples were analyzed, in computer by the AutoCAD system to verification of the linear dimensional alteration and observed, in stereoscopic magnifying glass for analysis of the reproduction of details. The color stability was analyzed by means of spectrophotometer. The dimensional alteration and color stability values had been submitted to the analysis of variance and Tukey test (p<0.05). For the analysis of detail reproduction, the 0 -2 scores were used It can be observed that the factor: chemical disinfection had no influenced statistically on dimensional stability, detail reproduction and color stability values. Accelerated aging had influenced statistically on dimensional stability values after 1008 hours. About detail reproduction, all samples exhibited score 2 for all analyzed periods. Pigment and opacifier association was more stable for chromatic stability test in all analyzed... (Complete abstract, click electronic address below)
84

Influência do intemperismo natural ou induzido sobre a estabilidade cromática de próteses faciais, em função do material de confecção e da pigmentação

Santos, Daniela Micheline dos [UNESP] 21 January 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-01-21Bitstream added on 2014-06-13T19:58:22Z : No. of bitstreams: 1 santos_dm_me_araca.pdf: 1205156 bytes, checksum: fffe6214d9a798b0c0b924994c235e30 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O maior problema enfrentado pelo protesista bucomaxilofacial é reproduzir a cor exata da pele do paciente, proporcionando uma estética agradável. Para alcançar este objetivo, o profissional deve ter materiais que possibilitem uma fácil caracterização, mantendo por um longo período de tempo a cor obtida. O propósito do presente estudo foi avaliar a estabilidade de cor de resinas acrílicas (Rapidaflex, Lentaflex e Resina Acrílica Termopolimerizável incolor e pigmentada) e de um silicone (Silastic MDX4-4210 incolor e com pigmentação) utilizados na confecção de próteses faciais, submetidos ao intemperismo natural ou artificial. Foram confeccionados 120 corpos-de-prova distribuídos em doze grupos. Metade dos corpos-de-prova foram submetidos ao envelhecimento natural por 180 dias, e a outra metade ao envelhecimento acelerado por 1008 horas. A alteração cromática dos corpos-de-prova foi verificada por meio da análise visual e da espectrofotometria de reflexão (Shimadzu, Kyoto, Japão). Os resultados foram submetidos à análise estatística pelos testes de Variância (ANOVA) de dois fatores e Tukey, com significância de 5%. Pode-se observar pela análise espectrofotométrica e visual que, independente do tipo de envelhecimento, ocorreu alteração de cor, estatisticamente significativa, entre alguns materiais. Os corpos-de-prova submetidos ao envelhecimento natural apresentaram maiores valores de alteração de cor do que aqueles submetidos ao envelhecimento acelerado. Todos os materiais sofreram alteração cromática pela influência da exposição ao meio ambiente ou pela ação do envelhecimento acelerado. / The great problem that confronts the maxillofacial prosthodontist is reproduces the accurate color of the patient’s skin, providing a satisfactory esthetic. Attempt to reach this purpose; the clinician should have materials to make an easy characterization, keeping the color by the time. The aim of this study was to evaluate the color stability of acrylic resins (Rapidaflex, Lentaflex and heat-cured colorless and pigmented acrylic resins) and a silicone (colorless and pigmented Silastic MDX4-4210) used to the confection of facial prostheses, submitted to natural or artificial weathering. 120 samples were made and distributed in twelve groups. 60 samples were submitted to the natural aging by 180 days, and the other half were submitted to the accelerated aging by 1008 hours. The chromatic differences were verified by means of the visual analysis and reflection spectrophotometer (Shimadzu, Kyoto, Japan). The results were analyzed by two-way analysis of variance (ANOVA) and Tukey tests (P<0,05). Color changes, between some materials, were observed by spectrophotometer and visual analysis, independently of the type of aging; it was statistically significant. The samples submitted to the natural aging showed higher values than the samples submitted to the accelerated aging. All materials suffered chromatic differences because to the environment exposure or the accelerated aging.
85

Avaliação da desadaptação e microdureza superficial de quatro resinas acrílicas para base de dentaduras utilizando métodos de polimerização e armazenagem em água

Miessi, Ana Carolina [UNESP] 29 September 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-09-29Bitstream added on 2014-06-13T19:37:36Z : No. of bitstreams: 1 miessi_ac_me_araca.pdf: 741354 bytes, checksum: ba78d27d53c30aac75b9b79cea2cc8e6 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo deste trabalho foi avaliar a desadaptação e a microdureza superficial de quatro tipos de resinas acrílicas para base de dentaduras, em função de período de armazenagem em água de seis meses. Foram confeccionados vinte e cinco conjuntos modelo de gesso-base de resina, utilizando-se quatro resinas acrílicas: QC-20 que foi submetida à polimerização convencional (de acordo com as instruções dos fabricantes) e por energia de microondas (840 W por três minutos), Vipi Cril submetida à polimerização convencional (fabricante), Vipi Wave e Onda Cryl que receberam polimerização por energia de microondas conforme as recomendações dos fabricantes. Após a polimerização, os conjuntos modelo de gesso-base de resina foram seccionados na região posterior correspondente a região de post-dam para a leitura da desadaptação, com auxílio de um microscópio comparador, em três pontos referenciais: crista dos rebordos direito e esquerdo e região mediana do palato. Os conjuntos seccionados foram, então, imersos em água destilada a 35 l 2ºC por período de noventa dias, após o qual uma segunda leitura da desadaptação foi realizada. Imediatamente, os conjuntos modelo-base de resina foram separados e a bases de resina retiradas para a remoção dos excessos grosseiros da borda até o limite estabelecido pelo modelo de gesso. Posteriormente, as bases de resina acrílica foram fixadas nos respectivos modelos com adesivo de presa rápida colocado na região correspondente à crista do rebordo alveolar e uma terceira leitura para analisar a desadaptação, nos pontos referenciais, foi realizada. Após a terceira leitura, os conjuntos ficaram novamente imersos em água destilada a 35 l 2ºC e armazenados em estufa por um período de mais noventa dias, findo o qual uma quarta leitura nos pontos previamente demarcados foi... / The aim of this work was to evaluate the missfitting and the superficial microhardness of four acrylic resins types for dentures base due to storage period in six months water. 25 model sets of resin plaster-base have been confectioned using four acrylic resins: QC-20, which was submitted to the conventional polymerization (in accordance with the manufacturer's instructions) and microwaves energy polymerization (840W for three minutes) and Vipi Wave and Onda Cryl, which have received microwaves energy polymerization also in accordance with the manufacturer's recommendations. After the polymerization process, the model sets of resin plaster-base were parted in the corresponding posterior region, the post-dam region, for the missfitting analysis. This was supported by a comparing microscope in three reference points: right and left crest of ridges and palate's middle region. The parted sets have been, then, immersed in distilled water about 35 to 2°C, for a 90-day period which was followed by a second missfitting analysis. The resin base-model sets were immediately separated and the resin bases were immediately removed to promote the edge coarse excesses' removal until the limit established by the plaster model. Later, the acrylic resin bases were fixed in the respective models with fast stick adhesive, which was placed in the corresponding region to the alveolar crest of ridges. A third analysis to study the missfitting in the reference points was carried through. After the third analysis the sets were immersed again in distilled water about 35 to 2ºC and stored in a stove for a certain period, which exceeded 90 days. As soon as this period was finished, a fourth analysis was carried through in the points previously outlined (180 days total analysis period...(Complete abstract, click electronic address below)
86

Avaliação da estabilidade cromática da pintura de íris em próteses oculares polimerizadas por energia de microondas, variando a cor, a tinta e o método de secagem

Fernandes, Aline Úrsula Rocha [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2004Bitstream added on 2014-06-13T19:16:54Z : No. of bitstreams: 1 fernandes_aur_me_araca.pdf: 952229 bytes, checksum: 8e65200d34f1586880d463d53baa7659 (MD5) / Universidade Estadual Paulista (UNESP) / A íris artificial é a estrutura da prótese ocular responsável pela sua dissimulação e estética. O propósito do presente trabalho foi avaliar a alteração de cor de tintas utilizadas na pintura de íris em próteses oculares polimerizadas por energia de microondas, variando-se tinta, cor e método de secagem. Para o estudo, foram confeccionados cinco discos em resina termopolimerizável por microondas para cada tinta analisada: acrílica hidrossolúvel, automotiva à base de nitrocelulose, guache hidrossolúvel e a óleo, nas cores marrom e azul, para os métodos de secagem natural e por radiação infravermelha, perfazendo um total de 80 corpos-de-prova. Cada corpo-de-prova foi constituído por um disco de resina acrílica incolor e outro, de igual dimensão, de resina acrílica de coloração branca de esclera e, entre os dois discos, a pintura. Os corposde- prova foram submetidos a uma câmara de envelhecimento acelerado sob radiação ultravioleta, por 1008 horas. Para avaliar as variações de cor foi usado um espectrofotômetro de reflexão. Os resultados foram analisados estatisticamente por Análise de Variância e teste de Tukey a 5% de significância. Todas as tintas sofreram alteração cromática. A tinta a óleo apresentou a maior resistência frente ao envelhecimento acelerado, independente da cor e do método de secagem. / The artificial iris is the structure of the ocular prosthesis responsible for its dissimulation and aesthetics. The objective of the present study was to evaluate the color stability of paint used for iris painting for ocular prosthesis polymerized with microwaves, varying painting, color and drying method. For the study, 80 discs in heat-curing for microwaves acrylic resin were made, five discs for each paint analyzed: acrylic water-soluble paints, automotive nitrocellulose paints, watercolor paints and oil paints, for the colors brown and blue, for both natural and infrared drying methods. Each specimen was constituted of one disc in colorless acrylic resin and another colored with a basic sclera pigment. The painting was accomplished in one of the surfaces of one of the discs. The specimens were submitted to an artificial aging chamber under ultraviolet light, during 1008 hours. To evaluate color changes a reflective spectrophotometer was used. The data were statistically analyzed by Variance Analysis and Tukey’s test. All paints suffered color alteration. The oil paints presented the highest resistance to artificial aging regardless the pigment and the drying method.
87

Prótese parcial removível de extremidade livre associada a um implante osseointegrado: influência do ligamento periodontal na distribuição interna das tensões

Archangelo, Carlos Marcelo [UNESP] 06 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-06Bitstream added on 2014-06-13T20:58:51Z : No. of bitstreams: 1 archangelo_cm_me_araca.pdf: 2727002 bytes, checksum: 70ce356e1f90c64c2cd8afe4655ae354 (MD5) / Universidade Estadual Paulista (UNESP) / Em função da adoção de hipóteses simplificadoras nos estudos através do método dos elementos finitos (MEF), os dados sobre a menor solicitação das estruturas de suporte na associação da prótese parcial removível de extremidade livre (PPREL) com um implante osseointegrado são inconclusivos. Assim, foi objetivo do presente estudo avaliar, através do MEF bidimensional, a distribuição interna das tensões nas estruturas de suporte da PPREL associada a um implante osseointegrado, em função da reprodução homogênea e não-homogênea do ligamento periodontal (LP). Para isso, 6 modelos (M) foram criados no programa AutoCAD 2005 (Autodesk Inc.; USA), representando: MA - hemiarco contendo somente o dente 33 e o rebordo desdentado para distal; MB - semelhante ao A, com uma PPREL substituindo os dentes ausentes; MC - semelhante ao B, com um implante (Sistema Bränemark - 3,75 mm x 10,0 mm) na região retromolar suportando a base da prótese; MD, ME e MF semelhantes aos modelos A, B e C, respectivamente, com exceção do LP, que foi modelado de forma não-homogênea, com a representação de 4 conjuntos de fibras: fibras da crista, horizontais, oblíquas e apicais. Após isso, os modelos foram exportados para o programa de elementos finitos ANSYS 8.0, e carregados com forças estritamente verticais de 50N em cada ponta de cúspide, fracionadas em 5 pontos de 10N. Os mapas gerais de tensões evidenciaram máxima e mínima concentração de tensões de (em MPa): MA (58,976 e 0,0045); MB (77,863 e 0,0551); MC (207,195 e 0,0057); MD (110,33 e 0,0137); ME (191,36 e 0,0044) e MF (326,60 e 0,0076), com deslocamento máximo de (mm): MA (0,0631); MB (0,1263); MC (0,1142); MD (0,2709); ME (0,1960) e MF (0,2019). / The application of many hypotheses in a finite element analysis (FEA) has been critical to obtain precise results in the removable partial denture treatment associated with an osseointegrated implant. In view of that, the purpose of the present study was to evaluated, through 2-D finite element analysis, the stress distribution in the support structures of a free-end saddle removable partial denture (RPD) associated with an osseointegrated implant, in function of the homogenous and non-homogenous condition for the periodontal ligament. For this, 6 models (M) were created in the AutoCAD software (Autodesk Inc.; USA), representing: MA - hemiarch contain only the natural tooth (33) and edentulous space in the posterior region; MB - similar to MA, with an RPD replacing the absent teeth; MC - similar to MB, with an osseointegrated implant (Branemark System - 3.75 x 10.00 mm) positioned in a posterior region in order to support the RPD base; MD, ME and MF - identical to MA, MB and MC, respectively; however, in these models, the periodontal ligament was considered an non-homogenous structure by the incorporation of four fibers groups in a sagital plane: alveolar crest fibers, horizontals, oblique, and apical fibers. After this, the models were exported to the finite element program (ANSYS 8.0) and loaded with verticals forces (50N) in each cusp. The results showed maximum and minimum stress (MPa): MA (58.976 and 0.0045); MB (77.863 and 0.0551); MC (207.195 and 0.0057); MD (110.33 and 0.0137); ME (191.36 and 0.0044) and MF (326.60 and 0.0076). The maximum displacement (mm) was: MA (0.0631); MB (0.1263); MC (0.1142); MD (0.2709); ME (0.2019) and MF (0.2019). (Complete abstract click eletronic address below)
88

Influência do processamento de próteses totais superiores em função da profundidade do palato: análise da movimentação dos dentes artificiais por computação gráfica

Vedovatto, Eduardo [UNESP] 09 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-09Bitstream added on 2014-06-13T19:37:37Z : No. of bitstreams: 1 vedovatto_e_me_araca.pdf: 3678407 bytes, checksum: 61a0add7350fb3375bfca3d4c3dcaff0 (MD5) / Universidade Estadual Paulista (UNESP) / Em função do relacionamento existente entre a profundidade do palato e as alterações das bases de resina acrílica, esse trabalho investigou a movimentação dos dentes que ocorrem quando próteses totais são processadas com diferentes materiais e técnicas e a relação com o formato do palato. Foram confeccionadas vinte e oito réplicas de próteses totais sobre modelos maxilares com palato raso e vinte e oito réplicas para o palato profundo, idênticas quanto ao enceramento e posicionamento dos dentes. As próteses foram divididas em oito grupos com sete espécimes cada, de acordo com o tipo de resina utilizada, o material utilizado para inclusão em mufla e o tipo de palato. Foram demarcados pontos sobre os dentes que serviram de referência para as mensurações através do software AutoCAD 2005. As mensurações foram realizadas em dois estágios: após o enceramento das próteses e após a demuflagem (não separadas do modelo). Os resultados foram submetidos à análise de variância e as comparações ao teste de Tukey com probabilidade de 5%. Os resultados mostraram que não houve diferença estatisticamente significante entre os grupos estudados, porém quando a análise ocorreu num contexto geral, diferença estatisticamente significativa foi observada para as variáveis, formato de palato e material de inclusão. Baseado nos resultados pode-se concluir que: o formato do palato influencia nas alterações dos dentes artificiais; o palato profundo sofreu alterações dentais significantemente inferiores que o palato raso; as próteses incluídas com silicone apresentaram alterações significantemente superiores às incluídas com gesso; o tipo de resina utilizada não acarretou em alterações estatísticamente significantes entre si; a região posterior das próteses apresentou maiores alterações em relação à região anterior. / About the relationship between the palate depth and the changes in acrylic resins base-plate, this work investigate the teeth movement that occurs when the complete dentures were processed by different materials, techniques and its relation to the palatal form. Twenty eight samples of complete dentures in maxillary cast with shallow palate form and twenty eight with deep palate form were constructed for the study. The samples presented similarities in the artificial teeth position. This prosthesis were divided in eight groups with seven specimens each, in agreement with the resin type for inclusion, the type of material used in the covering and the type of the palate depth. Points were demarcated on the teeth, which served as reference for the measurements of the segments (among the teeth), through software AutoCAD 2005. The measurements are accomplished in two moments: after the waxed and after the desflasking (not descasting). The results were submitted to the analysis of variance and comparisons to the Tukeyþs test with probability of 5%. The results showed no statistical significantly differences between the groups, but when the variables were study in global context difference were observed for the palatal form and covering materials. Based on the results conclude that: the palatal form influence on the changes of teeth position. The deep palate showed alterations significantly inferior that presented for the shallow palate. The silicon used for the covering results in greater alterations in relation to the stone mold. The type of resin not differs in the alterations of teeth position (not significantly). The change of teeth position was greater in the posterior region compares to the anterior region of the prosthesis.
89

Avaliação da estabilidade de cor após o envelhecimento acelerado de dois silicones pigmentados ou não para uso em próteses faciais

Mancuso, Daniela Nardi [UNESP] 03 October 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-10-03Bitstream added on 2014-06-13T20:37:56Z : No. of bitstreams: 1 mancuso_dn_me_araca.pdf: 2113835 bytes, checksum: 27a105a29a2894608038cc448f18dd65 (MD5) / Universidade Estadual Paulista (UNESP) / O objetivo desta pesquisa foi o de avaliar a estabilidade de cor dos silicones faciais pigmentados e não pigmentados após o envelhecimento acelerado. Foram utilizados dois silicones, sendo um de fabricação estrangeira, próprio para próteses faciais, e um silicone acético de fabricação nacional, de uso industrial. Foram confeccionados 24 corpos-de-prova para cada silicone, divididos em grupos incolor e pigmentados intrinsecamente com: cerâmica; maquiagem; óxido de ferro. Os grupos foram submetidos ao sistema acelerado de envelhecimento para não-metálicos - ultravioleta B / condensação (Comexim, Brasil). Foi feita leitura inicial e após períodos correspondentes a 163, 351, 692 e 1000 horas de envelhecimento, através do método visual de comparação e da análise por espectrofotômetro de reflexão Color-Eye (MacBeth, USA), utilizando o Sistema CIE L*a*b*. Os valores foram submetidos à análise de variância e teste de Tukey em nível de 5% de probabilidade. Todos os grupos apresentaram estabilidade de cor no método visual de comparação. Mas, com relação à espectrofotometria de reflexão, após as 1000 horas de envelhecimento acelerado, tanto o 732 RTV, quanto o MDX, pigmentados com maquiagem, apresentaram alteração de cor. Para o grupo incolor, em 351 horas de envelhecimento, tanto o 732 RTV, quanto o MDX, apresentaram alteração. Conclui-se então que os dois silicones possuem boa estabilidade de cor em todos os grupos estudados, com exceção da maquiagem que foi considerada a mais instável dentre os pigmentos para os dois silicones. / The objective of this research was evaluating the color stability of the facial silicones pigmented and without pigmentation after the accelerated aging. A foreign silicone created specifically for facial prostheses and a national acetic silicon for industrial use were used in research. 20 bodies-of-proof were made for each silicone, divided in colorless and intrinsically pigmented groups with: ceramic; make-up; oxide of iron. The groups were submitted to the accelerated System of aging for no-metallic - Ultraviolet B / condensation (Comexim, Brazil). An initial evaluation and evaluations after 163, 351, 692 and 1000 hours of aging were made. The visual method of comparison and the analysis for reflection spectrophotometer Color-Eye (MacBeth, USES) were used with the CIE L*a*b * System. The values were submitted to the variance analysis and Tukeyþs test in level of 5% of probability. All groups presented color stability in visual method. After 1000 hours of accelerated aging, Silastic 732 RTV and MDX, both pigmented with make-up presented color change in spectrophotometer analysis. The Silastic 732 RTV and MDX colorless groups presented color change in 351 hours of aging. It was concluded that all groups of both silicones had good color stability, except make-up group that was considered the most unstable pigment for both silicones.
90

Estudo comparativo in vitro do efeito da ciclagem térmica sobre a resistência à tração de copings metálicos cimentados sobre dentes naturais, utilizando se de dois agentes cimentantes /

Silva, Eduardo Galera da. January 1997 (has links)
Orientador: João Vieira de Moraes / Banca: Celso -Ite Tanaka / Banca: Maria Amélia Maximo de Araújo / Resumo: O estudo avaliou a resistência ao teste de arrancamento de coroas totais metálicas (NiCrBe), cimentadas em dentes humanos naturais extraídos (terceiros molares), com preparos padronizados realizado num aparelho especialmente idealizado para tal, baseado no princípio do funcionamento do torno mecânico. As coroas foram cimentadas com cimento de fosfato de zinco e cimento adesivo de resina. O total da amostra foi de sessenta dentes e as respectivas coroas, divididas em trinta para o grupo controle e trinta para o grupo experimental. Para o grupo controle, imediatamente após as cimentações, os corpos de prova foram armazenados em água a 37ºC por 48h antes de serem submetidos ao teste de tração. Para o grupo experimental, anteriormente ao teste de arrancamento, os trinta corpos de prova foram submetidos à ciclagem térmica com variações de 6, 61 e 37ºC, num total de 8 mil ciclos. Os resultados mostraram para o grupo controle, coroas cimentadas com cimento de fosfato de zinco, uma resistência média de 32,33Kgf. Nas amostras cimentadas com Panavía 21 os dentes não resistiram à remoção das coroas dos respectivos preparos, ocorrendo fratura em 100% dos dentes. Para o grupo experimental, a resistência média oferecida ao teste de arrancamento pelas coroas cimentadas com cimento de fosfato de zinco foi de 27,63Kgf e para as cimentadas com Panavia Ex de 35,00Kgf. Em geral, os resultados mostraram uma diminuição da resistência à tração oferecida pelos agentes cimentantes, quando os corpos de prova foram submetidos previamente à cíclagem térmica. Surpreendentemente, houve uma grande variação em relação aos dados encontrados nos testes de tração, tanto para o cimento de fosfato de zinco como para o cimento de resina, sob as duas condições analisadas, sem e com ciclagem térmica / Abstract: This study evaluated the tensile bond strenght of complete metal crowns (Ni Cr Be) bonded to sound natural extracted teeth on which standardized preparations were carried out with a special designed device based on the lathe principie. Crowns were luted with zinc phosphate cement and a resin adhesive cement (Panavia 21 ). 60 extracted third molars were separated in two groups of 30, the first was used as a control group and the second as a test group. For the control group, after luting the crowns to the prepared teeth the specimens were immersed in water at 37ºC and stored for 48h before being submitted to the tensile bond strenght test. For the test group, after luting the crowns to the prepared teeth, specimens were thermocycled with temperatura changes of 6, 61 and 37ºC to 8.000 cycles. Results for the control groups showed that crowns luted with ZPC presented a mean tensile strenght of 32,33kgf. Teeth with crowns luted with the resin adhesive cement showed fractures for all the specimens. Results for the test groups showed that specimens luted with ZPC presented a mean tensile strenght of 27,63kgf and those with Panavia Ex, 35,00kgf. Overall results showed reduced strenght when specimens were thermocycled prior to the tests. Unexpected results were found for both cements under thermocycling or not. Several teeth fractures ocurred during the tests, for both groups luted with both cements / Mestre

Page generated in 0.0626 seconds