• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 139
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 145
  • 60
  • 36
  • 35
  • 31
  • 30
  • 27
  • 24
  • 23
  • 21
  • 19
  • 19
  • 16
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Desajuste marginal e influencia na pre-carga de parafusos e nas tensões induzidas as fixações de pilares metaloplasticos sobre-fundidos / Marginal misfit and influence in the pre-load and the stress-induced setting of the metaloplastic abutments

Luthi, Leonardo Flores, 1984- 15 August 2018 (has links)
Orientador: Guilherme Elias Pessanha Henriques / Dissertação (mestrado) - Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-15T12:37:57Z (GMT). No. of bitstreams: 1 Luthi_LeonardoFlores_M.pdf: 40460066 bytes, checksum: 7100a1650e58ebfc4a879fff3da50814 (MD5) Previous issue date: 2010 / Resumo: Pilares tipo UCLA calcináveis são de ampla aplicabilidade na Implantodontia, pois permitem a manipulação em laboratório a custo reduzido e a individualização das próteses em função de cada paciente. Entretanto, apresentam piores resultados de adaptação marginal que os pilares pré-fabricados, embora estes agreguem custos significativamente superiores. Pilares UCLA metaloplásticos para sobre-fundição surgiram neste interstício, com prerrogativas de menores custos que os pré-fabricados e melhor adaptação que os calcináveis. Atualmente encontram-se, predominantemente, com base em liga de Ni-Cr-Ti ou Co-Cr. Todavia, não há dados relativos ao seu desempenho após a sobre-fundição, tão pouco, diante das ofertas, qual seria a melhor escolha. O objetivo neste estudo foi avaliar os desajustes marginais e a influência na indução de tensão e no destorque de parafusos protéticos de próteses confeccionadas com pilares UCLA metaloplásticos confrontando seus resultados com pilares UCLA calcináveis. Foram confeccionadas quarenta infraestruturas metálicas simulando próteses parciais fixas de três elementos retidas por dois implantes osseointegrados, obtidas por fundição a partir de transferências realizadas no modelo mestre. As estruturas foram separadas em quatro grupos (n=10) : G1, cilíndros protéticos tipo UCLA metaloplásticos com base em Co-Cr; G2, cilíndros protéticos tipo do UCLA calcináveis e fundidos em liga de Co-Cr; G3, por cilíndros protéticos tipo UCLA metaloplásticos com base em Ni-Cr-Ti; e G4, por cilíndros protéticos tipo do UCLA calcináveis e fundidos em liga de Ni-Cr-Ti. Para mensuração dos valores de desajuste marginal foi utilizada a técnica do parafuso único, o método de extensometria foi usado para análise das tensões, e os valores de pré-carga dos parafusos, após a ciclagem mecânica, foram obtidos por meio de torquímetro eletrônico digital. Os dados de desajuste marginal e tensão foram verificados antes e após a ciclagem mecânica, já os valores de pré-carga foram obtidos em intervalos de 100 mil ciclos. Os dados foram submetidos à análise variância (Três Fatores), seguidos de teste de Tukey (p=0,05) e a presença de correlação foi verificada por meio do teste de Pearson. Não foi encontrada diferença significativa entre os tipos de pilares para o desajuste, tensão e pré-carga. Os valores médios para desajuste (µm) foram G1 (3608,7 ± 1429,6) G2 (7918,3 ± 5055,9) G3 (4577,3 4017,2) G4 (9824,2 ± 1100,6). Os valores médios para tensão (gf) foram G1 (7918,3 ± 5208,8) G2 (3608,8 ± 2335,9) G3 (9824,3 ± 4125,5) G4 (4577,3 ± 15510,3). Os valores médios de pré-carga (Ncm) dentre os ciclos 0 (11,7 ± 3,8), 100 mil (9,7 ± 3,4), 200 mil (8,9 ± 3,7), 300 mil (9,3 ± 3,2), 400 mil (9,7 ± 3,4), 500 mil (10,6 ± 4). O uso de pilares metáloplasticos não reduziu os valores de desajuste marginal e tensão quando comparados aos calcináveis. A liga de Co-Cr apresentou os menores valores de desajuste marginal. O tipo de pilar e a liga utilizada influenciaram negativamente na perda de pré-carga. Não existe correlação entre tensão, desajuste marginal e pré-carga. / Abstract: Castable UCLA abutments are of wide applicability in dental implants, because they allow the manipulation in the laboratory at low cost and individualization of abutments for each patient. However, they show the worse results of marginal adaptation then the fabricated, although these aggregate costs significantly higher. UCLA premachined abutments for casting came in this interstice, with those of a lower cost than pre-made and better adaptation of the abutment. Nowadays, they are manufactured predominantly based on Ni-Cr-Ti or Co-Cr alloys. However, there is no data on its performance after the overcasting, and little is known about which one would be the best choice. Thus, the aim of this study was to analyze the marginal misfit and its influence on tension induction and in preload values of prosthetic screws in prostheses made with premachined UCLA abutmens. Forty frameworks were prepared simulating three-element metal fixed partial dentures retained by two osseointegrated implants, which were obtained through casting of acrylic resin frameworks waxed in a master model. The structures were distributed into four groups (n = 10): Group 1- premachined Co-Cr UCLA abutment; Group 2- casted Co-Cr UCLA abtument (control group 1); Group 3- premachined Ni-Cr-Ti UCLA abutment and Group 4- casted Ni-Cr-Ti UCLA abutment (control group 2). To measure the values of marginal misfit the single screw technique was used. The method of strain gage was used to analyze the stresses; and the values of preload of the bolts after cycling mechanics, were obtained by means of digital electronic torque meter. The data of marginal misfit and strain were obtained before and after of the mechanical cycling, but the values of pre-load were obtained at intervals of 100 thousand cycles. The data were submitted to variance analysis (Three-Way), followed by Tukey test (p=0.05) and the presence of correlation was verified by means of the Pearson correlation. The average values for marginal misfit (µm) were, G1 (3608.7 ± 1429.6), G2 (7918.3 ± 5055.9), G3( 4577.3 ± 4017.2), G4 (9824,2 ± 1100.6). The average values for tension (gf) were: G1 (7918,3 ± 5208.8), G2 (3608.8 ± 2335.9), G3 (9824.3 ± 4125.5) and G4 (4577.3 ± 15510.3). The averages values of preload (Ncm) among the phases: 0 (11.7 ± 3.8), 100 thousand (9.7 ± 3.4), 200 thousand (8.9 ± 3.7) 300 thousand (9.3 ± 3.2), 400 thousand (9.7 ± 3.4), 500 thousand (10.6 ± 4). The use of premachined UCLA abutment did not reduce the values of marginal misfit and strain when compared with the plastic UCLA abutments. The alloy of Co-Cr showed the lowest values of marginal misfit. The kind of abutmetns and alloy used influenced the values of preload. There was no correlation between strain, marginal misfit and preload. / Mestrado / Protese Dental / Mestre em Clínica Odontológica
112

Influência do material de infraestrutura e do desajuste vertical de próteses parciais fixas implantossuportadas nas tensões transmitidas às estruturas protéticas e ao tecido ósseo peri-implantar / Influence of framework material and vertical misfit of implant-suported partial prostheses on the stresses in prosthetic structures and peri-implant bone tissue

Bacchi, Ataís, 1986- 19 August 2018 (has links)
Orientador: Rafael Leonardo Xediek Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-19T19:18:16Z (GMT). No. of bitstreams: 1 Bacchi_Atais_M.pdf: 865962 bytes, checksum: 55e25bc8a48c9b1870a41c704082365a (MD5) Previous issue date: 2012 / Resumo: O objetivo neste estudo foi avaliar a influência do material de infraestrutura e diferentes níves de desajuste vertical na concentração de tensões em prótese parcial fixa implantossuportada (infraestrutura e porcelana de cobertura), parafuso de retenção e tecido ósseo peri-implantar durante o assentamento protético e frente à aplicação de carga oclusal. Um modelo tridimensional de elementos finitos de uma porção posterior de mandíbula contendo dois implantes osseointegrados nas posições de segundo pré-molar e segundo molar, suportando uma prótese parcial fixa foi construído utilizando software específico de modelagem (SolidWorks 2010). Modelos de elementos finitos foram obtidos pela importação do modelo sólido ao software de simulação mecânica (ANSYS Workbench 11). Os modelos foram separados em grupos de acordo com o material de infraestrutura (liga de ouro tipo IV, liga de prata-paládio, titânio comercialmente puro, liga de cobalto-cromo ou zircônia) e o nível de desajuste vertical (10 ?m, 50 ?m e 100 ?m) criado na interface prótese-implante do segundo pré-molar. A concentração de tensões foi avaliada nas seguintes condições: (1) assentamento protético; e (2) cargas oclusais simultâneas de 110 N vertical e 15 N horizontal em cada dente. Os resultados obtidos mostraram que as infraestruturas mais rígidas apresentam maior concentração de tensões internas; entretanto, promoveram menores concentrações de tensão sobre a porcelana de recobrimento, em ambas condições avaliadas. Na análise do assentamento protético, materiais mais rígidos para infraestruturas aumentaram os valores de tensão no parafuso de retenção e não causaram diferença relevante nas tensões no tecido ósseo peri-implantar. Quando a carga foi aplicada, o uso de infraestruturas mais rígidas promoveu redução de tensões no parafuso de retenção e no tecido ósseo peri-implantar. Em ambas condições avaliadas um considerável aumento na concentração de tensões foi obsevado em todas as estruturas com a amplificação do desajuste. Nas diferentes simulações, o material de infraestrutura exerceu considerável influência nas tensões transmitidas às estruturas avaliadas, exceto ao tecido ósseo peri-implantar em condições de assentamento. Aumento de tensões em todas as estruturas pode ser observado com o aumento do desajuste / Abstract: The aim in this study was to evaluate the influence of the framework material and vertical misfit on the stresses created in an implant-supported partial prosthesis (framework and porcelain veneer), retention screw and peri-implant bone tissue during the settlement of the prosthesis and under load conditions. A 3-D Finite Element model of a posterior part of a jaw with two osseointegrated implants at the place of the right second pre-molar and second molar supporting an implant-supported fixed partial prosthesis was constructed using specific modeling software (SolidWorks 2010). Finite element models were obtained by importing the solid model into mechanical simulation software (ANSYS Workbench 11). The models were divided into groups according to the framework material (type IV gold alloy, silver-palladium alloy, commercially pure titanium, cobalt-chromium alloy or zirconia) and vertical misfit level (10 ?m, 50 ?m and 100 ?m) created at the second pre-molar implant-prosthesis interface. The stress concentration was evaluated in the following conditions: (1) settlement of the prosthesis; and (2) simultaneous loads of 110 N vertical and 15 N horizontal in each tooth. The obtained results showed that stiffer frameworks presented higher stress concentrations in it and led to lower stresses in the porcelain veneer, in both conditions. In the analysis of settlement of the prosthesis, stiffer framework materials increased the stress values in the retention screw and did not cause a relevant difference in the stresses values in peri-implant bone tissue. When the load was applied, the use of more stiffness frameworks led to lower stresses in the retention screw, and peri-implant bone tissue. In both conditions evaluated, considerable raise of stress concentration was observed in all the structures within misfit amplification. Comparing the results of the different simulations, the framework materials presented a considerable influence on the stress concentration in the structures evaluated, except on the peri-implant bone tissue during the settlement of the prosthesis, while a considerable increase of the stress in all the structures was observed with the increase of the misfit / Mestrado / Protese Dental / Mestre em Clínica Odontológica
113

Avaliação da precisão de diferentes técnicas para obtenção de modelos de trabalho de próteses implantorretidas / Evaluation of different cast techniques accuracy for implant-retained prosthesis

Rodrigues, Mariana Agustinho, 1987- 19 August 2018 (has links)
Orientador: Guilherme Elias Pessanha Henriques / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-19T22:04:29Z (GMT). No. of bitstreams: 1 Rodrigues_MarianaAgustinho_M.pdf: 1199483 bytes, checksum: a7e857503f4eeab6a93e110c0445bc98 (MD5) Previous issue date: 2012 / Resumo: O intuito deste trabalho foi comparar diferentes técnicas de preenchimento do molde com gesso e verificar uma metodologia que fosse precisa o bastante para o julgamento das técnicas. Foram obtidos 40 modelos de gesso a partir de uma matriz metálica simulando uma situação clinica de prótese fixa implantorretida de três elementos. Os 40 modelos foram confeccionados segundo quatro técnicas de preenchimento do molde com gesso tipo IV (n=10), sendo assim foram obtidos os seguintes grupos: Grupo 1- 10 modelos de trabalho a partir do preenchimento do molde com gesso em porção única; Grupo 2- 10 modelos de trabalho obtidos a partir do preenchimento do molde com gesso em duas porções; Grupo 3- 10 modelos de trabalho obtidos segundo a técnica do manguito; Grupo 4- 10 modelos de trabalho obtidos a partir do preenchimento do molde com gesso realizando-se a união prévia dos análogos com haste metálica. Foi confeccionada estrutura metálica em titânio utilizada para mensurar os dejasustes marginais e tensão. Os desajustes verticais foram avaliados por meio de observação de desajuste marginal em microscópio com aumento de 120X e 0,1?m de precisão segundo protocolo do parafuso único para teste de passividade em estruturas implantorretidas. A análise de tensão ocorrida sobre a barra metálica foi avaliada por extensometria pela adaptação de dois strain gauges. Os dados foram submetidos à análise variância (ANOVA-1 fator), seguidos de teste de Tukey (?=0,05) para comparação entre os grupos. Foi avaliado presença de correlação entre tensão e desajuste vertical utilizando-se teste de Pearson. Não houve diferença estatística entre as técnicas de preenchimento do molde avaliadas quando comparados os valores de desajuste marginal (p=0,979), entretanto, quando se compara os valores médios de tensão sobre a barra, foi observado diferença estatística significante entre as técnicas do manguito e da união rígida dos análogos de implante (p=0,027). Desta forma, a técnica de união rígida dos análogos previamente a moldagem apresentou resultados similares à técnica convencional e uma técnica adequada para obtenção de modelos de trabalho. A utilização de strain gauges mostrou-se adequada para a avaliação de tensões ocorridas sobre a barra e comparação entre as técnicas de obtenção de modelos de gesso. Não houve correlação entre desajuste marginal e tensão ocorrida na barra / Abstract: The aim of this study was to evaluate the precision of four different mold filling techniques and verify an accurate methodology to evaluate these techniques. It was obtained 40 casts using four from a metallic matrix simulating three unit implant retained prosthesis. The molds were filled using four different techniques (n=10) following the four groups (n=10): Group 1- casts obtained with a single portion filling technique; Group 2- by using a two-step filling technique; Group 3- by using the latex cylinder technique; Group 4- by joining the implant analogues previously to the mold filling. A titanium framework was obtained used as reference to evaluate the marginal misfit and tension forces in each cast. The vertical misfit was measured with an optical microscope with an increase of 120 times following the single screw test protocol. The strain was quantified using strain gauges. Data were analyzed by ANOVA- 1 way and Tukey test (?=0,05). The correlation presence between strain and vertical misfit was evaluated by Pearson test. The misfit values did not present statistic difference (p=0,979). The strain results showed statistic difference between groups 3 and 4 (p=0,027). The splinting technique was considered as efficient as the conventional technique. The strain gauges methodology was accurate on strain measurements and cast distortion evaluation. There was no correlation between strains and marginal misfit / Mestrado / Protese Dental / Mestre em Clínica Odontológica
114

Eficácia do uso do Templating na artroplastia total do quadril.

Devito, Fábio Stucchi 17 April 2009 (has links)
Made available in DSpace on 2016-01-26T12:51:22Z (GMT). No. of bitstreams: 1 fabiostuchidevito_tese.pdf: 1050230 bytes, checksum: 52d8e95acef4a4ba2f5e60d301266786 (MD5) Previous issue date: 2009-04-17 / Total hip arthroplasty is a surgery with a high success rate, providing pain relief and improvement of the articular mobility. Long-term success is related to the position and orientation of the acetabular and femoral components. Traditional preoperative planning entails radiographic analysis of the pelvis, in which a template is placed on the image, allowing an analysis of the appropriate size of the Exeter cemented prosthesis. Objective: To evaluate the effectiveness of traditional preoperative planning with the use of templating. Patients and Method: Forty-three anteroposterior X-rays were analyzed by three experienced surgeons. The evaluation of each surgeon was compared with the actual prosthesis used in the surgery and also compared with the assessment of the other two surgeons. Cohen's Kappa concordance test and weighted Kappa indexes using quadratic weighting were used for statistical analysis with a confidence interval of 95%. Results: The preoperative evaluations of Surgeons A, B and C were divided into the analysis of the sizes of the acetabular cup, stem and plug of the distal femoral canal. Surgeon A obtained a moderate agreement in relation to the acetabular component and substantial agreements in relation to the stem and plug. Surgeon B had moderate agreement in relation to both the acetabulum and the stem and substantial agreement in relation to the plug. Surgeon C obtained moderate agreement in relation to the analysis of the acetabulum and the plug and substantial agreement for the stem. The intra-observer agreement test demonstrated a prevalence of slight agreement in relation to the acetabulum and substantial agreement in relation to the stem and to the plug. Conclusion: Templating used in preoperative planning proved effective; however, there was a prevalence of slight and moderate agreement in relation to the size of the acetabular component according to the inter- and intra-observer analysis. / A artroplastia total do quadril é uma cirurgia com alto índice de sucesso, atuando no alívio da dor e melhora da mobilidade articular e seu êxito a longo prazo relaciona-se à posição e orientação do componente acetabular e femoral. O planejamento pré-operatório tradicional consiste na análise radiográfica da bacia, na qual será sobreposto um templating , o que permite a análise do tamanho adequado da prótese Exeter cimentada. Objetivo: Avaliar a eficácia do planejamento pré-operatório tradicional pelo uso do templating . Casuística e Método: Quarenta e três radiografias na posição antero-posterior e foram analisadas por três cirurgiões experientes; as avaliações de cada cirurgião foram comparadas com a prótese utilizada na cirurgia e cada resultado comparado com os resultados dos outros dois. Para avaliação, utilizou-se o teste de concordância do Capa de Cohen e do Capa ponderado, com ponderação quadrática e intervalo de confiança de 95%.Resultados: Os resultados pré-operatório encontrados pelo examinadores A, B e C foram divididos como análise do tamanho do acetábulo, haste e plug do canal femoral distal. O cirurgião A obteve em relação ao componente acetabular uma concordância moderada, e em relação à haste e ao plug uma concordância substancial. O cirurgião B apresentou resultado de concordância moderada em relação ao acetábulo e à haste e substancial em relação ao plug. O cirurgião C na análise acetabular e do plug obteve concordância moderada e substancial quanto à haste. O teste de concordância intra-observador apresentou uma prevalência da concordância leve em relação ao acetábulo e substancial em relação à haste e ao plug. Conclusão: O templating utilizado no planejamento pré-operatório mostrou-se eficaz, no entanto, em relação ao tamanho do componente acetabular houve um predomínio de concordância leve e moderada na análise inter e intraobservador.
115

Studies on implantation of anorganic bone in cystic jaw lesions

Hjørting-Hansen, Erik. January 1970 (has links)
Thesis--København Tandlægehøjskole. / Summary in Danish. Bibliography: p. 179-194.
116

Studies on implantation of anorganic bone in cystic jaw lesions

Hjørting-Hansen, Erik. January 1970 (has links)
Thesis--København Tandlægehøjskole. / Summary in Danish. Bibliography: p. 179-194.
117

Avaliação da influência da força de mordida na prótese parcial removível classe I mandibular associada ao implante osseointegrado, pelo método dos elementos finitos

Lucas, Liliana Vicente Melo de [UNESP] January 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2003Bitstream added on 2014-06-13T20:18:39Z : No. of bitstreams: 1 lucas_lvm_me_araca.pdf: 5609405 bytes, checksum: 11adc5666b38e0dfa7a5f25c666fc6f2 (MD5) / A associação entre as próteses parciais removíveis e os implantes osseointegrados é, ainda, uma opção de tratamento muito pouco explorada na Odontologia reabilitadora moderna. Por isso, o objetivo deste estudo é avaliar, utilizando o método dos elementos finitos bidimensional, a distribuição de tensão nas estruturas de suporte da prótese parcial removível de extremidade livre (PPREL) associada a um implante osseointegrado de 10,0 x 3,75 mm (Sistema Branemark), localizado na região posterior do rebordo alveolar desdentado, atuando como suporte para a base da prótese. Para tanto, foram criados três modelos, os quais, em corte sagital, representam: modelo A (MA) – hemiarco contendo o dente natural 33 somente e o A rebordo desdentado distal; modelo B (MB) – semelhante ao MA, com uma PPREL convencional substituindo os dentes ausentes; modelo C (MC) – semelhante ao anterior, com um implante na região posterior do rebordo, sob a base da prótese. Com o auxílio do programa de elementos finitos ANSYS 5.4, os modelos foram carregados com forças verticais e oblíquas de 45º, tanto no sentido de mesial para distal como no sentido inverso, de magnitude de 50 N, em cada ponta de cúspide. A análise dos mapas de tensões permitiu concluir que: 1) a tendência de deslocamento no modelo com a PPR apoiada sobre implante é menor que no modelo com a prótese somente; 2) as forças oblíquas de 45º promovem uma tendência de deslocamento e valores de tensão maiores que a força vertical; 3) a força oblíqua de 45º, no sentido de mesial para distal, gera valores de tensão menores que a de distal para mesial e 4) a presença do implante osseointegrado, sob a base da prótese, promove alívio do dente suporte. / The association among the removable partial dentures and the osseointegrated implants is still a non very explored option of treatment in the modern prosthetic dentistry. Because of this, the objective of this study is to evaluate, using the two-dimensional finite element analysis, the tension distribution in the support structures of the distal extension removable partial denture (RPD) associated with a 10.0 x 3.75 mm osseointegrated implant (Branemark System), located in the posterior area of the toothless alveolar edge, acting as support for the prosthesis base. Then, three plane strain models were created, represented in sagital cut: Model A (MA) - hemiarc containing the natural tooth 33 and the toothless alveolar edge; Model B (MB) - similar to MA, with a conventional RPD substituting the absent teeth; Model C (MC) - similar to the previous, with an implant in the posterior area of the edge, under the denture base. With the aid of the finite element program ANSYS 5.4, the models were loaded with vertical and 45º inclined forces, in both mesial and distal sides, with 50 N, on each peak point. The analysis of the tensions map allowed to conclude that: 1) the displacement tendency in the model with the RPD supported by the implant is smaller than the model with prosthesis only; 2) the oblique forces of 45º promote a displacement tendency and larger tension values than the vertical force; 3) the mesial to distal 45º oblique force generates smaller tension values than the one of distal to mesial and 4) the presence of the osseointegrated implant, under the denture base, promotes relief to the support tooth.
118

Efeito da desinfecção química e do envelhecimento acelerado sobre a, estabilidade dimensional, reprodução e manutenção de detalhes, dureza “Shore A”, deterioração e estabilidade de cor de silicone para próteses faciais com distintas pigmentações

Pesqueira, Aldieris Alves [UNESP] 13 April 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-04-13Bitstream added on 2014-06-13T20:58:51Z : No. of bitstreams: 1 pesqueira_aa_me_araca.pdf: 540641 bytes, checksum: 5dfe2f80d73fb4a9cb52016d432619cf (MD5) / Este estudo teve como objetivo avaliar a estabilidade dimensional, reprodução e manutenção de detalhes, dureza “Shore A”, deterioração e estabilidade de cor, de um silicone facial, com distintas pigmentações, sob a influência da desinfecção e do envelhecimento acelerado. Para isso foram obtidos 60 corpos-de-prova, utilizando o silicone Silastic MDX 4- 4210, divididos em 3 grupos: sem pigmentação, pigmentado com pó de maquiagem e pigmentado com cerâmica. Metade dos corpos-de-prova de cada grupo foram submetidas à desinfecção com Efferdent e a outra metade com sabão neutro por 60 dias. Após esse período todos os corpos-de-prova (n=10) foram levados a uma câmara de envelhecimento acelerado para corpos não metálicos. Os ensaios de deterioração, estabilidade dimensional, reprodução e manutenção de detalhes, dureza Shore A e estabilidade de cor foram realizados após sua confecção, desinfecção e nos intervalos de cada ciclo de envelhecimento acelerado (252, 504 e 1008 horas). Os corpos-de-prova foram analisados, em computador pelo sistema AutoCAD para verificação da alteração dimensional linear e observados, em lupa estereoscópica para a análise da reprodução de detalhes. A dureza dos materiais foi analisada em durômetro Shore A e pesados em balança digital de precisão para análise da deterioração. A estabilidade de cor foi analisada por meio de espectrofotometria. Os valores encontrados dos testes de estabilidade dimensional, reprodução e manutenção de detalhes, dureza “Shore a“ e estabilidade de cor foram submetidos à análise de variância e teste de Tukey em nível de 1% de probabilidade. Para a análise da reprodução e manutenção de detalhes foi utilizado escore. Pôde-se observar que os fatores desinfecção química e o envelhecimento acelerado influenciaram estatisticamente na deterioração, estabilidade dimensional, dureza... / The aim of this study was to evaluate the dimensional stability, reproduction and maintenance of details, Shore A hardness, deterioration and color stability of facial silicone, with different pigmentation, on the influence of the disinfection and accelerated wheatering. 60 samples were obtained, using silicone Silastic MDX 4-4210, divided in 3 groups: nonpigmented, pigmented with make-up powder and pigmented with ceramics. The half of the samples of each group was submitted to the disinfection with Efferdent and another one with neutral soap per 60 days. After this period all the samples were taken to a chamber of accelerated wheatering for not metallic bodies (n=10). The tests of deterioration, dimensional stability, maintenance of the details, Shore A hardness and color stability were realized after the confection, disinfection and in the intervals of each cycle of accelerated wheatering (252, 504 e 1008 horas). Samples were weighty in digital balance for analysis of deterioration. Analyzed, in computer by the AutoCAD system to verification of the linear dimensional alteration and observed, in stereoscopic magnifying glass for analysis of the reproduction of details. Materials hardness was analyzed in Shore A durometer and the color stability by means of spectrophotometer. The values had been submitted to the analysis of variance and Tukey test (1%). It can be observed that the factors: chemical disinfection and the accelerated wheatering had influenced statistically in deterioration, dimensional stability, Shore A hardness and color stability of the materials independently of the pigmented. With relation to the reproduction and maintenance of details, the values did not change independently of the pigmented, disinfection and accelerated wheatering.
119

Análise por computação gráfica da variação da posição relativa dos dentes artificiais antes e após o processamento de próteses totais superiores

Shibayama, Ricardo [UNESP] 19 September 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-09-19Bitstream added on 2014-06-13T19:37:38Z : No. of bitstreams: 1 shibayama_r_me_araca.pdf: 3106543 bytes, checksum: c84fd00a6f34341aaf54e2572db11b66 (MD5) / Investigamos a alteração da posição dos dentes artificiais durante o processamento de próteses totais, utilizando as resinas de marcas comerciais QC 20 (Dentsply) e Onda Cryl (Clássico - específico de microondas), com inclusão em gesso e com muralha de silicone, polimerizadas tanto pelo método de banho por água quente, quanto pela polimerização por energia de microondas. Foram utilizadas 40 amostras, divididas em 4 grupos de 10, que receberam os seguintes tipos de processamento. a) grupo 1: incluídos em muflas metálicas com muralha de gesso pedra e polimerização convencional. b) grupo 2: incluídos em muflas de fibra de vidro com muralha de gesso pedra e polimerização com microondas. c) grupo 3: incluídos em muflas metálicas com muralha de silicone e polimerização convencional. d) grupo 4: incluídos em muflas de fibra de vidro com muralha de silicone e polimerização por energia de microondas. Para detecção dos deslocamentos dentais utilizamos um guia de resina acrílica com 5 pontos pré-determinados que proporcionou pontos de referência nas réplicas que permitiram mensurar tais deslocamentos através da utilização do programa de computador AutoCad. Com os resultados obtidos podemos concluir que: a) todas as amostras sofreram alteração da posição dos dentes após o processamento, b) a técnica com a menor movimentação dos dentes artificiais foi a técnica 4. / This study investigated artificial tooth movement during the procedures of complete dentures base, using two different types of resins: QC 20 (Dentsply) and OndaCryl (Clássico specify for microwave energy), with gypsum stone mould and silicone mould. We used thermopolymerization in water bath and microwave polymerization. The forty samples utilized were divided into four groups of ten, which received the following type of inclusion and processing. Group 1: included in metallic flasks with gypsum stone mould and thermopolymerization in water bath and microwave polymerization; Group 2: included in resin-fiber glass flasks with gypsum stone mold and microwave polymerization; Group 3: included in metallic flasks with silicone mold and thermopolymerization in water bath; Group 4: included in resin-fiber glass flasks with silicone mould and microwave polymerization. For the measurement of artificial tooth movement, we used a resin acrylic guide with five daily determined points which provide references points. The AutoCad R 14 computer program was utilized for the measurements. All data were submitted to ANOVA and Tukey test. With the results we can conclude that: a) all the samples suffer artificial tooth movement, b) the smaller artificial tooth movement happen in group four.
120

Aplicação do processo sol-gel na produção de recobrimentos de hidroxiapatita sobre ligas a base de Ti empregadas em implantes odontológicos

Santos, Márcio Luiz dos [UNESP] January 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:11Z (GMT). No. of bitstreams: 0 Previous issue date: 2005Bitstream added on 2014-06-13T20:23:09Z : No. of bitstreams: 1 santos_ml_dr_araiq.pdf: 3271586 bytes, checksum: 67395fcc4c57825507f1303f136c6b25 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Nos últimos anos a área de biomateriais tem direcionado estudos para o desenvolvimento de um material sintético ou artificial que tenha propriedades físico-químicas, biológicas e mecânicas semelhantes ao do tecido ósseo. Dentre as diversas alternativas, uma das mais estudadas é o biocompósito metal-cerâmica, em que se utilizando técnicas de recobrimentos, consegue-se combinar boa biocompatibilidade, propriedades mecânicas e resistência à corrosão do titânio e suas ligas, com a excelente bioatividade das biocerâmicas de fosfato de cálcio, especificamente a hidroxiapatita. Para tanto, o processo sol-gel é uma das técnicas mais flexíveis e promissoras. O objetivo do presente trabalho foi estudar as características físico-químicas e as propriedades mecânicas do recobrimento de hidroxiapatita, obtido pelo processo sol-gel, com e sem pré-modificação de superfície dos substratos Ti-6Al-4V e Ti-6Al-7Nb com depósito de dióxido de titânio via plasma-spray. Os resultados mostraram a formação de uma camada rugosa e porosa de dióxido de titânio com forte interação com o substrato metálico devido à similaridade dos dois materiais. Investigou-se quatro diferentes procedimentos de deposição; onde se variou o número de camadas, temperaturas de calcinações, objetivando-se atingir morfologias e fases similares. Pelas técnicas de caracterização utilizadas (MEV, FTIR e DRX), os recobrimentos obtidos pelo processo sol-gel apresentaram uma mistura de fases, hidroxiapatita e ß-TCP (fosfato tricálcio). As medidas de espessura, realizadas por MEV, para os quatro procedimentos demonstraram que o recobrimento com dez camadas apresentou-se intacto e uniforme, não sendo encontrados falhas ou trincas entre as camadas e o substrato, demonstrando ser um bom indicador de ligação interfacial, mesmo apresentando uma espessura de aproximadamente 20æm. / In recent years biomaterials area has addressed studies for the development of synthetic or artificial material that has chemical-physical, biological and mechanical properties similar to the bone tissue. Among several alternatives, one of the most studied is the metal-ceramic biocomposite, where using the technique coatings, had gotten to combine good biocompatibility, mechanical properties and corrosion resistance of the titanium and their alloys, with the excellent bioactivity of the calcium phosphate bioceramics, specifically the hydroxyapatite. For so much, the sol-gel process is one of the most flexible and promising techniques. The aim of the present work was to study the chemical-physical characteristics and mechanical properties of the hydroxyapatite coating obtained by the sol-gel process, with and without pre-modification of Ti-6Al-4V and Ti-6Al-7Nb substrate surface with titanium dioxide deposit by plasma-spray method. The results showed the formation of a rough and porous layer of titanium dioxide and with a strong interaction with the metallic substrate due to the similarity of the two materials. It was investigated four different deposition procedures, where the layer numbers and calcination temperatures was varied, being aimed at to reach morphology and phase similars. For the characterization techniques (SEM, FTIR and XRD) used, for it, the coatings obtained by the process sol-gel showed a mixture of phases, hydroxyapatite and ß-TCP (tricalcium phosphate). The thickness measurement, carried out by SEM, for the four procedures, demonstrated that coating with ten layers showed intact and uniform, not being found flaws or cracks between the layers and substrate, demonstrating so as being a good interfacial connection indicator, even presenting a thickness of approximately 20æm. The results of the microhardness Vickers tests has presented similar values for the different depositions number and heat treatment temperatures.

Page generated in 0.0362 seconds