• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 139
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 145
  • 60
  • 36
  • 35
  • 31
  • 30
  • 27
  • 24
  • 23
  • 21
  • 19
  • 19
  • 16
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Efeito do envelhecimento acelerado sobre a microdureza superficial, rugosidade e opacidade de resinas acrílicas incolores termopolimerizáveis e calotas oculares empregadas em prótese ocular, em função da espessura

Fernandes, Aline Úrsula Rocha [UNESP] 12 December 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-12-12Bitstream added on 2014-06-13T20:25:52Z : No. of bitstreams: 1 fernandes_aur_dr_araca.pdf: 3876257 bytes, checksum: 0b3f599e97b9e9ee18afc401d2068c8c (MD5) / As próteses oculares são responsáveis pelo restabelecimento da estética, harmonia facial e auto-estima do paciente anoftálmico. Confeccionados em resina acrílica, os olhos artificiais devem ser estéticos, perfeitamente polidos e resistentes a riscos, características que, quando não satisfeitas, podem gerar transtornos psicológicos, possíveis infecções ou inflamações originárias de substâncias e organismos depositados nas irregularidades superficiais da prótese. O propósito do estudo foi avaliar a microdureza e rugosidade superficiais e opacidade de calotas incolores próprias para prótese ocular e de três marcas de resina acrílica incolor termopolimerizável por banho de água quente de curta e média duração e duas por energia de microondas, em função do envelhecimento acelerado (1008 horas) e espessura (1 e 3,5 mm). Para o estudo, foram obtidas 120 amostras, distribuídas em 12 grupos (n= 10). A análise foi realizada por meio de microdurômetro (Shimadzu Corp., Kyoto, Japão), rugosímetro (TONKA Sul Americana Ltda., SP, Brasil) e espectrofotômetro de reflexão (Shimadzu Corp., Kyoto, Japão). Os valores obtidos antes e após envelhecimento acelerado foram analisados estatisticamente pela Análise de Variância de três fatores e pelo teste de Tukey a 1% de significância. Para o teste de microdureza, as calotas oculares e a resina QC 20 apresentaram, respectivamente, os maiores e menores valores de microdureza superficial, independente da variável avaliada; a espessura não influenciou a propriedade estudada e as amostras apresentaram valores médios de microdureza superficial maiores após o envelhecimento acelerado. / Artificial eyes are responsible for reestablishing the facial esthetics, harmony and self esteem of the anophthalmic patient. Made of acrylic resin, artificial eyes must be esthetic, perfectly polished and scratchresistant characteristics which, when not satisfied, may cause psychological disturbances, possible infections or inflammations originating from substances and organisms deposited on the surface irregularities of the prosthesis. The aim of this study was to assess the microhardness, surface roughness and opacity of colorless ocular button for the purpose of use in artificial eyes, and three brands of colorless acrylic resin heat-polymerizable by hot water bath of short and medium duration and two by microwave energy, as a function of accelerated aging (1008 hours) and thickness (1 and 3.5 mm). For this study, 120 samples were obtained, distributed into 12 groups (n=10). Analysis was performed by means of microhardness meter (Shimadzu Corp., Kyoto, Japan), rugosity meter (TONKA Sul Americana Ltda., SP, Brazil) and reflection spectrophotometer (Shimadzu Corp., Kyoto, Japan). The values obtained before and after accelerated aging were statistically analyzed by Analysis of Variance for 3 factors and the Tukey test at 1% significance. For the microhardness test, the ocular buttons and QC 20 resin respectively presented the highest and lowest surface microhardness values, irrespective of the variable assessed; the thickness had no influence on the studied property, and the samples presented higher mean surface microhardness values after accelerated aging. For the roughness test, there was no statistically significant difference with regard to accelerated aging; the resin Vipi Cril, at the thickness of 3.5 mm and ocular button at the thickness of 1 mm presented the lowest roughness value.
122

Análise da variação da posição dos dentes artificiais durante as fases específicas do processamento de próteses totais superiores mensurada por computação gráfica

Shibayama, Ricardo [UNESP] 23 March 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-03-23Bitstream added on 2014-06-13T19:24:19Z : No. of bitstreams: 1 shibayama_r_dr_araca.pdf: 1447114 bytes, checksum: 3c09de09a6fe8d140870e923ba0cd69a (MD5) / Foi investigada a alteração da posição dos dentes artificiais durante o processamento de próteses totais desde a fase de enceramento até o polimento, utilizando as resinas de marcas comerciais QC 20 (Dentsply) e Onda Cryl (Clássico - específico para microondas), com inclusão em gesso tipo II e com muralha de silicone, polimerizadas tanto pelo método de banho em água quente, quanto pela polimerização por energia de microondas. Foram utilizadas 40 amostras, obtidas de um modelo padrão e divididas em 4 grupos de 10, que receberam os seguintes tipos de processamento. a) grupo 1: incluídos em muflas metálicas com muralha de gesso pedra e polimerização por banho de água quente. b) grupo 2: incluídos em muflas de fibra de vidro com muralha de gesso pedra e polimerização por microondas. c) grupo 3: incluídos em muflas metálicas com muralha de silicone e polimerização por banho em água quente. d) grupo 4: incluídos em muflas de fibra de vidro com muralha de silicone e polimerização por energia de microondas. Para detecção dos deslocamentos dentais utilizou-se um guia de resina acrílica com 5 pontos pré-determinados nas cúspides dos dentes que proporcionaram pontos de referência nas réplicas permitindo mensurar tais deslocamentos através da digitalização das superfícies oclusais dos dentes e analisados por um programa de computador AutoCad. Baseados nos resultados obtidos, de acordo com os materiais e metodologia empregados, concluimos que: 1. Em todas as técnicas de processamento de prótese total estudadas houve alteração da posição dos dentes após o processamento. 2. A técnica de inclusão com muralha de silicone e polimerização por microondas (grupo 4) apresentou os menores valores de alterações na posição dos dentes durante toda a fase de processamento... / Artificial teeth position changes were investigated during the upper complete denture processing, resins QC 20 (Dentsply) and Onda Cryl (Clássico - specific for microwave energy) were used and flasked in type II gypsum stone mould or silicone mould, polymerized in hot water bath as well in microwave polymerization. Forty specimens were used, which were obtained from one standard cast, and divided into four groups of ten that were processed as the following: a) group I (control): flasked in metallic muffles with gypsum stone barrier and conventional polymerization. b) group II: flasked in glass fiber muffles with gypsum stone barrier and polymerization by microwave energy. c) group III: flasked in metallic muffles with silicone barrier and conventional polymerization. d) group IV: flasked in glass fiber muffles with silicone barrier and microwave polymerization. An acrylic resin guide was used to detect teeth displacements, this guide was marked with 5 predetermined points in teeth cuspids that has proportionate reference points in the replicas. These points were used to measure, by AutoCad software, teeth displacements by digitized occlusal surface of the teeth. Based upon the results, according to the employed material and method, the following can be concluded: 1. It was observed teeth position changes after denture processing in all experimental groups. 2. The technique of flasking with silicone mould and microwave polymerization (group 4) presented minor degree of teeth position changes during all the processing. 3. The segments that constitute the smaller triangle represented by the points of teeth 15, 21 and 25 showed more homogeneity and linearity than the bigger triangle represented by the cuspids of 17, 21 and 27. 4. These dimensional changes of shrinkage and expansion in both triangles followed a uniform sequence for all the segments, that is, as one segment changes, the others follow it, thus, they don t occur randomly.
123

Influência dos ciclos de cocção da porcelana na força de destorque de parafusos de estruturas implanto-retidas / Influence of porcelain fire cycles on detorque resistance of screws from implant-retained structures

Torres, José Walter Murta, 1958- 21 August 2018 (has links)
Orientador: Guilherme Elias Pessanha Henriques / Tese (Doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T23:50:10Z (GMT). No. of bitstreams: 1 Torres_JoseWalterMurta_D.pdf: 1581851 bytes, checksum: 0bbcce2409164d19a4e51f955b38d595 (MD5) Previous issue date: 2013 / Resumo: Este trabalho avaliou a resistência ao destorque em parafusos de estruturas metálicas implanto-retidas fundidas em níquel-cromo (Ni-Cr) após fundição e simulação dos ciclos de cocção da porcelana. Dois implantes hexágono externo - com 3,75 mm de diâmetro - foram posicionados, com o auxílio de um paralelômetro fresador (1000N; Bio-art), na posição de segundo pré-molar e segundo molar num troquel de resina acrílica, de maneira a ficarem parcialmente submersos na resina expondo apenas suas plataformas de adaptação. Foram confeccionados 10 troqueis de resina acrílica (n=10). A partir de cada troquel foi obtida, pelo método de fundição da cera perdida, uma infraestrutura implanto-retida utilizando-se dois cilindros calcináveis tipo UCLA. A amostra foi submetida à força de torque de seus parafusos de fixação a 20 Ncm, registrada por meio de um torquímetro digital de precisão (Torque Meter TQ-8800; Lutron), e reapertados após 10 minutos. A força de destorque foi registrada após 24 horas do torque inicial. A resistência ao destorque foi analisada após fundição da estrutura protética e simulação dos três ciclos de cocção da porcelana (opaco dentina e glaze). Foram obtidas médias de destorque para cada estrutura nas distintas etapas de avaliação no estudo. Os dados foram analisados estatisticamente pelos testes ANOVA one-way e Bonferroni, com nível de significância de 5% (p<0,05). Os valores das médias da força de destorque dos parafusos por fase foram 13,95 ± 1,12 Ncm para pós-fundição, 15,20 ± 1,18 Ncm para ciclo Opaco, 15,85 ± 1,13 Ncm para ciclo Dentina e 16,80 ± 1,03 Ncm para o glaze. A força de destorque dos parafusos após a fundição foi significativamente menor do que a obtida para os grupos que simularam o ciclo de cocção da porcelana (p<0,05). Entre as fases de simulação dos ciclos cerâmicos, observou-se maior valor da força de destorque para o glaze (p<0,05), não sendo observadas diferenças estatisticamente significantes entre as fases opaco e dentina (p>0,05). Foi possível verificar que os ciclos de cocção da porcelana influenciam a resistência ao destorque em parafusos de estruturas metálicas implanto-retidas fundidas em níquel-cromo (Ni-Cr). Observou-se que os valores de destorque aumentaram gradativamente com cada ciclo de cocção da porcelana / Abstract: This study evaluated the resistance to detorque of screws from implant-retained metal structures cast in nickel-chromium (Ni-Cr) after metal casting and simulation of porcelain firing cycle. Two external hex implants - with 3.75 mm diameters - were placed with the help of a parallelometer cutter (1000N; Bio-art), in the position of second premolar and second molar in acrylic resin die, so as to be partially submerged in the resin exposing only their platforms for adaptation. Thereupon, 10 dies were made with acrylic resin (n= 10). An implant-retained infrastructure from each die was obtained by the method of lost wax casting, using two UCLA cylinders. The sample of acrylic structures were subjected to 20 Ncm of torque to its fixing screws registered by means of a precision digital torque wrench (Torque Meter TQ-8800; Lutron) and retightened after 10 minutes. The measure of detorque was recorded 24 hours after the initial torque. The detorque resistance was analyzed after denture casting, followed by the simulation of porcelain firing cycles (opaque, dentin and glaze). Detorque averages were obtained for each structure at different stages of evaluation in this study. Data was statistically analyzed by one-way ANOVA and Bonferroni tests, at 5% significance level (p>0.05). We performed necessary statistical tests. The mean detorque force of the screws per phase were 13.95 ± 1.12 Ncm for post-casting; 15.20 ± 1.18 Ncm for cycle opaque; 15.85 ± 1.13 Ncm for cycle dentin; and 16.80 ± 1.03 Ncm for glazing. The screw's post-casting detorque resistance was significantly lower than that observed for the groups simulating porcelain firing cycles (p<0.05). Among groups simulating ceramic's cycles, the highest detorque resistance was observed for glaze group (p<0.05), with no significant statistical differences among opaque and dentin groups (p>0.05). It was possible that the porcelain firing cycle influenced detorque resistance of screws in implant-retained metal structures cast in nickel-chromium (Ni-Cr). It was observed that detorque values gradually increased after each porcelain firing cycle / Doutorado / Protese Dental / Doutor em Clínica Odontológica
124

[en] THE FIRST SILICONE WE NEVER FORGET: OF BREAST IMPLANTS IN ADOLESCENT GIRLS / [pt] O PRIMEIRO SILICONE A GENTE NUNCA ESQUECE: DO IMPLANTE DE PRÓTESE MAMÁRIA EM MENINAS ADOLESCENTES

FÁBIO LUIZ RODRIGUES 08 February 2017 (has links)
[pt] O implante de prótese mamária de silicone a que meninas adolescentes se submetem na atualidade se tornou um fenômeno cultural sem precedentes. Baseado em tal fenômeno, este trabalho pretende investigar o que move meninas adolescentes a se submeterem ao referido procedimento cirúrgico, a partir da noção de corpo representado para a psicanálise em articulação com o campo da cultura. O campo de pesquisa foi estabelecido a partir de declarações de meninas adolescentes que se submeteram ou iriam se submeter ao implante de prótese mamária de silicone, coletadas na mídia, através da internet com seus blogs, redes sociais e artigos jornalísticos. As considerações finais deste trabalho ressaltam que, diante da chamada crise da adolescência, o implante de prótese mamária de silicone a que meninas adolescentes se submetem remete ao projeto de alcançar um padrão de beleza imaginário que funcionaria como suporte subjetivo para tal crise. / [en] The silicone breast implants that adolescent girls undergo nowadays have become an unprecedented cultural phenomenon. Based on this phenomenon, it is intended to investigate what makes adolescent girls undergo such procedure from the idea of body representation for psychoanalysis interrelated with the idea of body for medicine and the field of culture. The research field was based on statements of adolescent girls who had or would have the silicone breast implants surgery, as well as media search, through the internet, with its blogs, social networks and journalistic articles. Results highlight that, facing with the so called adolescent crisis, the silicone breast implants which adolescent girls undergo take them to the project of reaching an imaginary standard of beauty that would work as a subjective support for such crisis.
125

Efeito de pastilhas higienizadoras efervescentes nos componentes da prótese parcial removível / Effect of effervescent denture tablets on the components of partial removable denture

Vasconcelos, Glenda Lara Lopes 09 February 2018 (has links)
Este estudo avaliou os efeitos de pastilhas efervescentes na superfície de liga de cobalto cromo (Co-Cr) e resina termopolimerizável, simulando um período de até 5 anos de imersão, como também analisar sua ação antimicrobiana. A partir de uma matriz metálica, padrões de cera circulares (12 x 3 mm) foram obtidos e fundidos em liga de Co-Cr (DeguDent®). As amostras foram imersas em: Polident 3 minutes® (P3M), Steradent® (St), Polident for Partials® (PP), Efferdent® (Ef), Corega Tabs® (CT), Nitradine® (Ni), Fixodent® (Fi) e Kukident® (K). Foi avaliada a resistência à corrosão (Ecorr, Ipass) (n=5) por meio do Potenciostato/Galvanostato. Foram realizadas análises qualitativas complementares com Microscópio Eletrônico de Varredura (MEV) e Espectrometria de Energia Dispersiva de Raios-X (EDS). Após o ensaio de corrosão, cada disco metálico foi incluído em mufla preparada por matrizes circulares de cera (20 x 5 mm), incorporando-o à resina acrílica termopolimerizável (Clássico Ltda®). Os grupos das 4 pastilhas que apresentaram a menor taxa de corrosão e da água destilada (controle) (n=9) foram analisados quanto à rugosidade da superfície metálica e da resina acrílica (Sa, &micro;m) por meio de microscopia confocal a laser. Foram avaliadas a alteração de cor (&Delta;E) da resina por meio de espectrocolorímetro no início e após a simulação de ½, 1, 2, 3, 4 e 5 anos e alteração de massa (g), no início e final, em balança de alta precisão. Para avaliação antimicrobiana, por meio da contagem de Unidades Formadoras de Colônia (UFC/mL), os espécimes mistos foram contaminados com biofilme misto composto por: S. mutans (Sm), S. aureus (Sa), C. albicans (Ca) e C. glabrata (Cg) e, posteriormente, imersos nas soluções higienizadoras, onde foram semeados em meios específicos para contagem das UFC. De acordo com os resultados obtidos (&alpha;=0,05), P3M causou a menor taxa de corrosão e Ni, o menor potencial de corrosão. Com o MEV, verificou-se evidenciação da microestrutura da liga metálica. Quanto à rugosidade superficial do metal, CT (p=0,009) e Ni (p=0,036) causaram aumento na rugosidade em relação ao tempo (Friedman). Na resina, houve aumento da rugosidade após 5 anos (p<0,01). Entre as soluções (Kruskal-Wallis), não houve diferença para ambos os materiais. Não houve diferença na cor da resina acrílica, tanto em relação às soluções (Kruskal Wallis) quanto aos tempos (Friedman). Não foram observadas alterações de massa (Kruskal-Wallis). Quanto à ação antimicrobiana (Kruskal-Wallis), Ni propiciou redução de UFC de Sm (p=0,001). Conclui-se que, embora todas as pastilhas efervescentes não tenham alterado a superfície do metal e da resina acrílica de maneira significativa, nenhuma apresentou ação antimicrobiana contra os microrganismos avaliados do biofilme misto; somente Ni reduziu a quantidade de S. mutans / The aim of this study were: to evaluate the effects of denture cleansers on the surface of cobalt chromium (Co-Cr) and heat-polymerized acrylic resin, simulating a period until 5 years of immersion, as well as to analyze its antimicrobial action. From a metal matrix, disc-shaped wax patterns (12 x 3 mm) were made and later were casting in Co-Cr alloy (DeguDent&trade;). The specimes were immersed in: Polident 3 minutes&trade; (P3M), Steradent&trade; (St), Polident for Partials&trade; (PP), Efferdent&trade; (Ef), Corega Tabs&trade; (CT), Nitradine&trade; (Ni), Fixodent&trade; (Fi) and Kukident&trade; (K). The corrosion resistance (Ecorr, Ipass) (n = 5) was evaluated by Potentiostat / Galvanostat. Further qualitative analyzes were performed with scanning electronic microscopy (SEM) and energy dispersive x-ray spectrometry (EDS). After the corrosion test, each metal disk was included in heat-cured acrylic resin (Clássico Ltda&trade;) using moulds previously prepared from circular wax matrices (20 x 5 mm). The four dentures cleansers with the lowest corrosive potential were analyzed for surface roughness of the metal and acrylic resin (Sa, &micro;m) by laser confocal microscopy. The color change (&Delta;E) of the resin was evaluated by means of a spectrocolorimeter at the beginning and after the simulation of ½, 1, 2, 3, 4 and 5 years and mass change (g), at the beginning and end, in high-precision balance. For antimicrobial evaluation, the mixed specimens (n = 9) were contaminated with multispecies biofilm [S. mutans (Sm), S. aureus (Sa), C. albicans (Ca) and C. glabrata (Cg)] and subsquently immersed in denture cleansers, where they were seeded in specific CFU / mL media. According to the results obtained (&alpha;=0.05), there was a significant difference: P3M presented the lowest corrosion rate and Ni, the lowest corrosion potential. According to SEM, the tablets effervescent provided evidence of the microstructure of the alloy. As for the surface roughness in the metal surface, CT (p = 0.009) and Ni (p = 0.036) showed increase in roughness in relation to time (Friedman). At the resin surface, the roughness growed after 5 years. Among the solutions (Kruskal-Wallis), there was no difference for both materials. There was no difference in the color of the acrylic resin (&delta;E), both for solution (Kruskal-Wallis), and for time (Friedman). Differences in weight weren\'t observed (Kruskal-Wallis). In antimicrobial action (Kruskal-Wallis), Ni group showed significant reduction for Sm (p=0.001). It\'s concluded that, although all the denture cleansers didn\'t significantly changed the surface of the metal and acrylic resin, none showed antimicrobial action against the evaluated microorganisms of the mixed biofilm; only Ni reduced the amount of S. mutans
126

[en] RESISTANCE ANALYSIS OF FIXED ZIRCONIA BRIDGES APPLIED IN SCREWED DENTAL PROSTHESIS / [pt] ANÁLISE DA RESISTÊNCIA DE PONTES FIXAS EM ZIRCÔNIA APLICADAS EM PRÓTESES DENTÁRIAS APARAFUSADAS

JOSE ALEX GONCALVES DE GALIZA 10 March 2015 (has links)
[pt] Esse trabalho teve como objetivo principal avaliar a resistência à falha da infraestrutura de uma prótese parcial fixa em zircônia de três elementos e aparafusada sobre implantes, através de análise de tensões por elementos finitos e determinação da resistência à fadiga da estrutura. Como objetivo secundário, foram avaliadas as distribuições das tensões nos demais componentes da prótese. Na análise de tensões, dois modelos distintos foram gerados, sendo o primeiro com prótese, implantes e parafusos similares àqueles adotados na clínica odontológica. Um segundo modelo, usado como controle, adotou uma geometria simplificada. As cargas mastigatórias foram aquelas usuais da literatura especializada e a análise por elementos finitos foi realizada através do programa Ansys Workbench 14.5. Os resultados das distribuições de tensões mostraram semelhanças entre os dois modelos, com pequenas variações relacionadas às geometrias empregadas. As tensões calculadas ficaram abaixo dos limites de resistência mecânica da zircônia e das ligas de titânio. No cálculo da vida em fadiga da prótese de zircônia um modelo analítico foi adotado prevendo uma vida infinita para o componente. / [en] The main goal of this work was to evaluate the failure resistance of a zirconia fixed partial denture of three elements screwed on implants by means of a finite element stress analysis and the determination of the fatigue strength of the structure. As a secondary objective, the stress distributions in the other components of the prosthesis were evaluated. In order to promote the stress analysis, two different models were generated, the first making use of prosthesis, implants and screws similar to those adopted in the dental clinic. A second model, used as control, adopted a simplified geometry. The masticatory loads were those presented usually in the literature and finite element analysis was performed making use of Ansys Workbench 14.5 program. The stress distribution results showed similarity in both models, with small variations related to the adopted geometries. The calculated stresses were smaller than the ultimate strength of the zirconia and titanium alloys. Concerning the fatigue life of the zirconia prosthesis an analytical model was adopted and estimated an infinite life for the component.
127

Influência do processamento de próteses totais maxilares com diferentes espessuras da base: análise gráfica da movimentação dos dentes artificiais

Mazaro, José Vitor Quinelli [UNESP] 15 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-15Bitstream added on 2014-06-13T20:18:38Z : No. of bitstreams: 1 mazaro_jvq_me_araca.pdf: 2035782 bytes, checksum: e67d1a0017e9c678266d158062acc962 (MD5) / Universidade Estadual Paulista (UNESP) / A relação existente entre os métodos de processamento das resinas acrílicas e a espessura de resina das bases de dentaduras, bem como a associação com o tamanho e forma do arco maxilar, tem sido um assunto bastante discutido no que diz respeito à possíveis alterações no posicionamento dos dentes e selamento posterior de próteses totais maxilares. Sendo assim, o propósito desse trabalho foi avaliar a movimentação dentária que ocorre durante o processamento de próteses totais maxilares com três diferentes espessuras de base, frente a dois métodos de inclusão e submetidas à polimerização por microondas. Quarenta e duas (42) amostras foram aleatoriamente divididas em 6 grupos de 7 amostras cada, respeitando, evidentemente, a espessura da base (1,25 mm - 2,50 mm - 3,75 mm) e o tipo de revestimento em mufla (silicone e gesso pedra). Pontos foram demarcados sobre os dentes artificiais para permitir a mensuração das R ee ssum o amostras através do software AutoCad. A diferença das médias dos segmentos entre o modelo encerado e demuflado de cada grupo foi submetida à analise de variância (ANOVA) e teste de Tukey. De acordo com os resultados obtidos pode-se concluir que: todas as técnicas de processamento juntamente com as diferentes espessuras de base de prótese total avaliadas apresentaram alteração na posição dos dentes artificiais após o processamento. A técnica de inclusão com barreira de silicone foi a que apresentou as maiores alterações dimensionais, independentemente da espessura. Na análise dos segmentos, houve uma maior alteração dos segmentos A/B/C (Triângulo maior) com relação aos segmentos D/E/F (Triângulo menor). Independente do tipo de inclusão, não houve diferença estatística entre as espessuras das bases (p<0,059), entretanto, analisando o comportamento de alteração, as prótese totais com bases mais finas apresentaram maior... . / The existent relationship between the methods of processing of the acrylic resins and the thickness of dentures bases resin, as well as the association with the size and form of the maxillary arch, it has been a subject quite discussed with regard to possible alterations in the teeth positioning and maxillary complete denture postdamming. So that, the aim of the study was to evaluate the dental movement that it happens during the processing of maxillary complete dentures with three base thickness different, front of two inclusion methods and submitted to the microwaves polymerization. Forty two (42) samples were randomly divided in 6 groups of 7 samples each, respecting, evidently, the base thickness (1,25 mm - 2,50 mm - 3,75 mm) and the type in flask investment (silicone and plaster stone). Points were demarcated on the artificial teeth to allow the measurement of the samples through the AutoCad software. The averages difference of the segments between the Ab ss tt rr a cc tt waxed model and deflasked of each group was submitted to it analysis of variance (ANOVA á=0,05) and Tukey test. In agreement with the obtained results it can be conclusion that: all the processing techniques together with the different thickness of complete denture base evaluated, presented alteration in the artificial teeth positionig after the processing. The silicone flasking technique was that presented the largest dimensional alterations, independently of the thickness. In the segments analysis, there was a larger alteration of the segments A/B/C (larger Triangle) regarding the segments D/E/F (smaller Triangle). Independent of the flasking type, there was not difference statistics among the thickness of the bases (p <0,059), however, analyzing the alteration behavior, thinner bases presented larger movement in the position of the artificial teeth than thicken base that complete denture them. The completed... (Complete abstract, click electronic address below).
128

Avaliação da influência da angulação do implante osseointegrado associado à prótese parcial removível classe I mandibular pelo método dos elementos finitos

Santos, Ciandrus Moraes de Freitas [UNESP] January 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2005Bitstream added on 2014-06-13T19:16:56Z : No. of bitstreams: 1 santos_cmf_me_araca.pdf: 1084188 bytes, checksum: 0a96538ac84e5167cd37297d47e91a27 (MD5) / Universidade Estadual Paulista (UNESP) / A resolução protética dos arcos com extremidades livres através da associação entre prótese parcial removível e implantes osseointegrados é, ainda, uma opção pouco utilizada na clínica odontológica. Quando dessa associação, na instalação do implante, por motivos anatômicos ou diversos, o mesmo pode ser instalado com certa angulação. Desse modo, o propósito dessa pesquisa é avaliar, através do método dos elementos finitos bidimensional, a distribuição de tensão e a tendência ao deslocamento nas estruturas de suporte de uma prótese parcial removível de extremidade livre (PPREL), e da própria PPREL, associada a um implante osseointegrado de 10,0 x 3,75 mm (Sistema Bränemark) com diferentes angulações, localizado na distal do rebordo residual, atuando apenas como suporte para a base da prótese. Foram utilizados 6 modelos, os quais, em corte sagital, representam: Modelo A (MA) - hemiarco contendo o dente natural 33 somente e o rebordo alveolar distal; Modelo B (MB) - semelhante ao MA, com um PPREL convencional substituindo os dentes ausentes; Modelo C (MC) - semelhante ao anterior, com um implante verticalizado a 0o na região distal do rebordo, sob a base da prótese; Modelo D (MD) - semelhante ao MC, com o implante angulado a 5º para mesial; Modelo E (ME) - semelhante ao MD, com o implante angulado a 15º para mesial; Modelo F (MF) - semelhante ao ME, com o implante angulado a 30º para mesial. Com o auxílio do programa de elementos finitos ANSYS 8.0, os modelos foram carregados com forças estritamente verticais de 50 N em cada ponta de cúspide. A análise dos Mapas permitiu concluir que: para a maioria das estruturas analisadas, quanto menor o ângulo do implante, menores as tensões observadas nos modelos; O MD (com implante a 5o) foi o que apresentou as melhores combinações de resultados, sendo portanto a melhor opção nas condições estudadas. / The prosthetic resolution of arches with free end saddles by association among removable partial denture and osseointegrated implants, still have a low use in dentistry clinic. This way, the purpose of this study was to evaluate, by the bidimensionsal finite element analysis, the tension distribution and the displacement tendency in the supporting structures of a free end removable partial denture (FERPD), and the own FERPD, associated to an osseointegrated implant of 10,0 x 3,75 mm (Bränemark System), located in the distal area of the free end saddle, acting solely as support for the prosthesis base. Six models in sagital cut were utilized. Such represented: Model A (MA) - hemi arch containing the inferior left canine and the free end saddle; Model B (MB) - similar to MA, with a conventional RPD substituting the absent teeth; Model C (MC) - similar to the previous, with a vertical implant (0o) in the distal of the free end saddle, under the prosthesis base; Model D (MD) - similar to the previous, with the implant in an angulation of 5° to the mesial; Model E (ME) - similar to the previous, with the implant in an angulation of 15°; Model F (MF) - similar to the previous, with the implant angulation of 30°. With the aid of the finite element analysis program ANSYS 8.0, the models were loaded with 50 N of vertical forces on each cuspid of the teeth. The maps analysis allowed conclude that: For the most of analyzed structures, as lower the implant's angle, the lower the observed tension in the models. The MD (implant at 5°) was the better results combination, being the best option in the studied conditions.
129

Avaliação da influência do diâmetro e comprimento do implante osseointegrado associado à PPR Classe I mandibular pelo método dos elementos finitos

Verri, Fellippo Ramos [UNESP] January 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2003Bitstream added on 2014-06-13T20:37:57Z : No. of bitstreams: 1 verri_fr_me_araca.pdf: 6651997 bytes, checksum: 6bb3237d2e73d295c300ea6f6f9c9014 (MD5) / A influência do diâmetro e do comprimento de implantes osseointegrados em associação com próteses parciais removíveis de extremidade livre (PPRELs) ainda não foi relatada na literatura. Dessa forma, este trabalho visou avaliar a esta influência, utilizando o método dos elementos finitos (MEF) bi-dimensional, associando implantes osseointegrados do sistema Branemark sob a base protética de uma PPREL, funcionando apenas como suporte, e analisando mapas de deslocamento e de tensão de von Mises. Para o estudo foram confeccionados oito modelos representativos de uma hemi-arcada mandibular com a presença apenas dos dentes 33 e 34, com as seguintes características: A - sem PPR; B - com PPR sem implante; C - com PPR e implante de 3,75 x 7,00 mm; D - com PPR e implante de 3,75 x 10,00 mm; E - com PPR e implante de 3,75 x 13,00 mm; F - com PPR e implante de 5,00 x 7,00 mm; G - com PPR e implante de 5,00 x 10,00 mm; H - com PPR e implante de 5,00 x 13,00 mm. As forças aplicadas foram estritamente verticais e de 50 N em cada ponta de cúspide. Pelos resultados notou-se que a presença da PPR sobrecarregou o dente suporte, bem como as demais estruturas de suporte da PPR quando comparadas com o modelo A. A presença do implante diminuiu as tensões, principalmente nas extremidades do rebordo desdentado, quando comparados o modelo B com os modelos que possuíam implantes associados. Tanto o comprimento quanto o diâmetro do implante tenderam a diminuir as tensões à medida que aumentavam suas dimensões. Pelos resultados foi possível concluir que: o modelo B foi o que apresentou a maior tendência a deslocamento; quanto maior o comprimento do implante, menores foram os valores do mapa de deslocamento; o modelo B apresentou níveis de tensão de von Mises superiores ao modelo A; os modelos com implantes associados apresentaram níveis menores de tensão de von Mises que o modelo B nas estruturas de suporte da PPR. / The influence of the diameter and length of osseointegrated implants in association with removable partial prostheses of distal-extension (DERPDs) it was not still reported in the literature. In that way, this study evaluated this influence, associating osseointegrated implants of the Branemark system under the prosthetic base of a DERPD, just working as support, and analyzing displacement and von Mises tension maps, using bi-dimensional finite element analysis (FEA). For this study, eight representative models of a lower hemi-arcade were made with the presence of only the teeth 33 and 34, with the following characteristics: A - without RPD; B - with RPD and without implants; C - with RPD and implant of 3,75 x 7,00 mm; D - with RPD and implant of 3,75 x 10,00 mm; E - with RPD and implant of 3,75 x 13,00 mm; F - with RPD and implant of 5,00 x 7,00 mm; G - with RPD and implant of 5,00 x 10,00 mm; H - with RPD and implant of 5,00 x 13,00 mm. The applied forces were strictly vertical and of 50 N in each edge tip. The results shown that the presence of RPD overloaded the support tooth, as well as the other structures of support of RPD when compared with the model A. The presence of the implants reduced the tensions, mainly in the extremities of the toothless edge, when compared model B with the models that possessed implant associated. So much the length as the diameter of the implants tended to reduce the tensions as increased your dimensions. For the results it was possible to conclude that: the model B was what presented the largest tendency to displacement; as larger the length of the it implants, smaller they were the values of the displacement map; the model B presented levels of von Mises tension superiors to the model A; the models with implant associated presented smaller levels of von Mises tension that the model B in the structures of support of RPD; the increase of the length and of the diameter of the implants.
130

Influência dos sistemas de retenção e da inclinação do rebordo residual em casos de próteses conjugadas Classe I mandibular: análise da distribuição das tensões pelo método da fotoelasticidade

Ferraço, Renato [UNESP] 24 April 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-04-24Bitstream added on 2014-06-13T19:37:37Z : No. of bitstreams: 1 ferraco_r_me_araca.pdf: 1898873 bytes, checksum: a4b549caf699d7868a711624716d6212 (MD5) / A reabilitação de pacientes classe I de Kennedy mandibular através de Prótese Parcial Removível é de difícil resolução devido a diferença de resiliência existente entre o ligamento periodontal dos dentes suportes e a mucosa do rebordo residual. A inclinação do rebordo residual no sentido sagital pode influenciar na distribuição das tensões transmitidas pela incidência de cargas em próteses parciais removíveis de extremidade livre associadas a próteses parciais fixas. Na associação da prótese parcial removível com próteses parciais fixas, o profissional tem como alternativa aos grampos tradicionais, o uso de encaixes extra-coronários que podem melhorar a estética e o funcionamento biomecânico do conjunto. Desse modo, o objetivo desse estudo foi avaliar a característica da distribuição de tensões em próteses parciais removíveis mandibulares de extremidade livre associadas a próteses parciais fixas nos dentes suporte com diferentes sistemas de retenção: (1) grampo por ação de pontas; (2) sistema ASC-52; (3) sistema ERA; e (4) encaixe de semi-precisão Score-PD, pela metodologia da fotoelasticidade. E, analisar a distribuição de tensões em próteses parciais removíveis mandibulares de extremidade livre associadas a próteses parciais fixas nos dentes suporte com diferentes sistemas de retenção: (1) grampo por ação de pontas e (2) sistema ERA, variando duas inclinações de rebordo residual: (1) horizontal e (2) descendente distal. Cargas axiais de 100N foram aplicadas sobre os dentes das próteses parciais removíveis. As imagens das aplicações foram capturadas e a distribuição das tensões foi avaliada, pela formação das franjas fotoelásticas. No primeiro estudo, a prótese com encaixes de semi-precisão produziu os maiores níveis de tensão na região de ápice, entre as raízes dos últimos dentes suporte e na porção mais distal do rebordo... / The rehabilitation of patients mandibular class I of Kennedy through Removable Partial Denture is difficult to solve because the difference in strength between the periodontal ligament of the abutment teeth and the residual ridge mucosa. The inclination of the residual ridge towards sagital may influence the distribution of stresses transmitted by the incidence of loads in distal extension removable partial dentures associated with fixed partial dentures. In association removable partial denture – fixed partial dentures, the professional has as alternative to the traditional clasps, the use of extra-coronary attachments that can improve the aesthetics and the biomechanics. Therefore, the objective of this study was to evaluate the characteristic distribution of tensions in mandibular distal extension removable partial dentures (1) “I” bar clasps, (2) ASC-52system, (3) ERA system, and (4) semi-precision Score-PD system, by the methodology of photoelasticity. And, analyze the distribution of tensions in mandibular distal extension removable partial dentures associated to the fixed partial dentures in the abutment teeth with different retention systems: (1) “I” bar clasps and (2) ERA system, ranging from two inclinations residual ridge: (1) horizontal and (2) distal descending. Axial loads of 100N were applied on the teeth of removable partial dentures. The images of the applications were captured and distribution of stress was assessed by the formation of the photoelastic fringes. In the first study, the prosthesis with semi-precision attachment produced the highest levels of tension in the region of apex, between the roots of the abutment teeth and in the more distal portion of the residual ridge. The prostheses with resilient attachments showed the largest fringes formations in the cervical-distal of the last abutment tooth. In the second study, horizontal ridge presented... (Complete abstract click electronic access below)

Page generated in 0.0563 seconds