• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 139
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 145
  • 60
  • 36
  • 35
  • 31
  • 30
  • 27
  • 24
  • 23
  • 21
  • 19
  • 19
  • 16
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Análise fotoelástica da tensão entre diferentes tipos de sistemas de retenção em próteses obturadoras palatinas implanto-retidas ou não e com ou sem reembasamento “soft”

Ribeiro, Paula do Prado [UNESP] 13 April 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-04-13Bitstream added on 2014-06-13T20:18:39Z : No. of bitstreams: 1 ribeiro_pp_me_araca.pdf: 1296460 bytes, checksum: 0aa88d770aee2b3e8787125e444deac4 (MD5) / O câncer da região de cabeça e pescoço é uma doença muito prevalente no Brasil, e as principais formas de tratamento são a cirurgia acompanhada ou não da radioterapia e quimioterapia. Perdas parciais ou totais de osso maxilar podem comprometer seriamente a fisiologia bucal causando sequelas como comunicações buconasosinosal. Neste caso, podese optar como forma de tratamento pela reabilitação protética com a aplicação de implantes osseointegrados. A literatura odontológica tem mostrado inúmeros trabalhos que avaliam a distribuição de forças com a finalidade de recolher melhores subsídios para o planejamento de próteses bucomaxilofaciais, que ainda é pouquíssimo explorada. Dentre os métodos utilizados, o da fotoelasticidade tem sido aceito, especialmente por permitir uma análise fiel da distribuição de forças. Assim, a proposta deste trabalho foi verificar a tendência de distribuição de forças e estresse, através do método fotoelástico, que incidem sobre diferentes tipos de sistemas de retenção em implantes (o’ring, barra clipe e o’ring/barra clipe) associado a próteses obturadoras palatinas implantoretidas e também em próteses obturadoras mucossuportadas (sem implante), utilizandose ou não de silicone com reembasamento direto (Sofreliner). O conjunto (prótese e modelo fotoelástico) foi posicionado em polariscópio circular e recebeu aplicação de carga de 100 N a velocidade de 10 mm/s no primeiro molar de cada prótese. Após as aplicações de carga houve a formação franjas correspondentes à tensão registrada. Então, as imagens foram transferidas para um computador e analisadas no programa ADOBE Photoshop. Ao se comparar os três sistemas de retenção das próteses obturadoras palatinas implantoretidas com a prótese mucossuportada (sem implantes), podese observar que as tensões foram distribuídas de forma mais homogênea... / The head and neck cancer is a very prevalent disease in Brazil and the main treatment is the surgery with or without radiation therapy and chemotherapy. Partial or total bone maxillary defects could involve seriously oral physiology causing consequences as buconasosinosal communications. In this case could be applied other option of treatment as prosthetic rehabilitation associated with osseointegrated implants. Scientific literature demonstrated countless studies that evaluate the force distribution with the aim to provide better subsidies for the planning of bucomaxillofacial prostheses, which still have few researches. Between the methodologies, the photoelastic method has been accepted; especially by allow an accurate analysis of the force distribution. Thus, the aim of this study was to verify the tendency of force distribution and the stress on different types of retention system (o’ring, clip bar and o’ring/clip bar) associated with palatal obturator prostheses with implant retention and conventional obturator prostheses (without implants), with or without silicone soft lining(Sofreliner), by means of photoelastic method. The set (prosthesis and photoelastic model) was located in circular polariscope and was applied a load of 100 load N at 10 mm/s on the first molar of each prostheses. After the load applications was registered the tension fringes. The images was transferred to a computer and analyzed at ADOBE Photoshop software. When compared the three retention systems of the palatal obturator prostheses and mucosupported prostheses (without implants), it can be observed that the stress was distributed more homogeneous and in lesser amount that the conventional prostheses, when compared to the other prostheses that presented implants and retention systems. With relation to stress distribution in the different retention systems, the bar clip... (Complete abstract click electronic access below)
132

Avaliação da biocompatibilidade de vários elastômeros de silicone implantados no tecido subcutâneo de ratos: estudo histológico e histomorfométrico

França, Diurianne Caroline Campos [UNESP] 22 August 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:20Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-08-22Bitstream added on 2014-06-13T19:11:58Z : No. of bitstreams: 1 franca_dcc_me_araca.pdf: 2609587 bytes, checksum: 8a7904cdb64c406b06f726af6ac60fbc (MD5) / Universidade Estadual Paulista (UNESP) / No presente estudo foram utilizados 60 ratos submetidos a implantes subcutâneos de quatro elastômeros de silicone, sendo três usados em prótese bucomaxilofacial, LIM 6050, MDX 4-4210 e Silastic 732 RTV industrial e um indicado para cirurgia plástica, o Silimed. O objetivo do estudo foi avaliar os materiais em relação à compatibilidade biológica tecidual, nos tempos pós-operatórios de sete, quinze e trinta dias, quando os animais foram sacrificados e as peças processadas e coradas pela hematoxilina e eosina para análise qualitativa e quantitativa dos espécimes. Pelo estudo histomorfométrico, oito áreas de 60,11 mm2 foram analisadas, contando-se as células mesenquimais, inflamatórias mononucleares, eosinófilos e as células gigantes do tipo corpo estranho. O experimento foi desenvolvido em dois capítulos, estudando-se separadamente os silicones de uso em prótese e o Silimed. No primeiro capítulo, a análise da biocompatibilidade dos implantes subcutâneos dos elastômeros de silicone LIM 6050, MDX 4-4210 e Silastic 732 RTV industrial, observou-se biocompatibilidade aceitável em todos eles, considerando-se o fato de que sua indicação protética dependeria em especial das características físicas próprias de cada material, pela mínima reação tecidual observada, além de que em sua forma sólida é fácil a adaptação aos tecidos. No segundo capítulo, o estudo se baseou na análise das reações referentes ao implante de silicone utilizado em cirurgia plástica (Silimed), constatando-se a presença de processo inflamatório ligeiramente maior no silicone gel em relação aos outros grupos, porém com níveis aceitáveis de biocompatibilidade, confirmada pela rara presença de células gigantes do tipo corpo estranho. Todos os dados foram submetidos à análise de variância e teste de Tukey, demonstrando que todos os materiais implantados iniciaram uma resposta... / In the present study 60 rats were submitted to subcutaneous implant of four elastomers of silicon, being three of use in bucomaxillofacial prosthesis, LIM 6050, MDX 4-4210 and Silastic 732 RTV industrial and a suitable one for plastic surgery, Silimed. The objective of the study was to evaluate the materials in relation to the tissue biological compatibility, in the postoperative times of seven, fifteen and thirty days, when the animals were sacrificed and the processed pieces and stained for the hematoxilin and eosin for qualitative and quantitative analysis of the specimens. For the histomorphometric study, eight areas of 60,11 mm2 were analyzed, being counted the mesenchimal cells, inflammatory cells, eosinophile and giant cells. The experiment was developed in two chapters, being studied the use silicons separately in prosthesis and Silimed. In the first chapter, the analysis of the biocompatibility of the subcutaneous implant of the elastomers of silicon LIM 6050, MDX 4-4210 and Silastic 732 RTV industrial, acceptable biocompatibility was observed in all of them, being considered the fact that your prosthetic indication would especially depend on the own physical characteristics of each material, for the low tissue reaction observed, in addition in your solid form it is easy the adaptation to the tissues. In the second chapter, the study based on the analysis of the referring reactions to the it implants of silicon used in plastic surgery (silimed), being verified the presence of inflammatory process lightly larger in relation to the other groups, however with acceptable levels of biocompatibility confirmed by the rare presence of giant cells of the type strange body. All the data were submitted to the variance analysis and test of Tukey, demonstrating that all the implanted materials began an acceptable tissue inflammatory reaction, with tissue reactions of light intensity the moderate... (Complete abstract, click electronic address below)
133

Avaliação do nível de inserção óssea do dente suporte em prótese parcial removível mandibular classe I associada a implante osseointegrado: análise pelo método dos elementos finitos

Verri, Fellippo Ramos [UNESP] 11 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-12-11Bitstream added on 2014-06-13T19:44:51Z : No. of bitstreams: 1 verri_fr_dr_araca.pdf: 1853726 bytes, checksum: 578403c1602d78c980bb821e076ea43c (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A colocação de PPR de extremidade livre no arco inferior é uma das mais complexas dentro da área protética. A associação desta com implantes na região distal tem melhorado biomecanicamente seu funcionamento. Porém, existem poucos estudos a respeito desta associação levando em consideração o nível de inserção óssea do dente suporte. Assim, o objetivo desta pesquisa foi avaliar, por meio do método dos elementos finitos bidimensional, a distribuição de tensão nas estruturas de suporte de uma PPREL, associada a um implante osseointegrado de 10,0 x 3,75 mm (Sistema Branemark), próximo ao dente suporte, com diferentes níveis de inserção óssea (íntegro e 1/2 da raiz) e com diferentes tipos de conexão entre a PPR e o dente suporte (apoio incisal e placa distal). Para o estudo, foram confeccionados 8 modelos mandibulares, de extremo livre, com a presença apenas do dente 33, sendo: MA - PPREL convencional, apoio incisal distal, inserção íntegra; MB - idem ao MA, mas utilizando placa distal; MC - idem ao MA, com implante de 3,75 x 10,0 mm e sistema ERA associado; MD - idem ao MC, mas utilizando placa distal; ME - idem ao MA, mas com perda de inserção de 1/2 da raiz; MF - idem ao MB, mas com perda de inserção de 1/2 da raiz; MG - idem ao MC, mas com perda de inserção de 1/2 da raiz; MH - idem ao MD, mas com perda de inserção de 1/2 da raiz. Com o auxilio do programa ANSYS 9.0, os modelos foram carregados com forças verticais de 50 N em cada ponta de cúspide. Os resultados foram obtidos pelos mapas de deslocamento e de tensão de von Mises e mostraram que o implante favorece a associação da forma descrita, que a placa possibilita um maior alívio e menor deslocamento do dente suporte, e que a perda do periodonto de suporte prejudica o prognóstico da prótese. / The rehabilitation with distal extension RPDA is very complex in the prosthetic area and the association with implants had improving its work biomechanical. However, there is little studies about this type of association and no study about the lost of insertion was encountered by FEA. So, the aim of this study was to evaluate, by FEA 2-D, the tension distribution in support structures of a DERPD associated with a osseointegrated implant of 10,0 x 3,75 mm (Branemark System), near to support tooth, with different levels of bone insertion (no lost and 1/2 of root) and with different type of connection between the DERPD and de support tooth (incisal rest and distal plate). For the study, 8 distal extension mandibular models were made, with the presence of tooth 33, presenting: MA - conventional DERPD, incisal rest, no bone lost; MB - like MA, but with distal plate; MC - like MA, but with implanto of 3,75 x 10,0 mm and ERA system associated; MD - like MC, but with distal plate; ME - like MA, but with bone lost of 1/2 of root; MF - like MB, but with bone lost of 1/2 of root; MG - like MC, but with bone lost of 1/2 of root; MH - like MD, but with bone lost of 1/2 of root. By mean of program of FEA ANSYS 9.0, the models were carried with axial forces of 50 N in each cusp tip. The results were obtained by dislodgement maps and von Mises tension maps and shown that the implant was benefit to association by the study, and the plate decreased the tension and the dislodgement of the support tooth, and the bone lost was prejudicial to prognostic of this type of prosthesis. By this methodology, was possible to conclude that: the introduction of an osseointegrated implant with ERA system used like this study decrease the dislodgement of above structures in all models.
134

Influência do formato do rebordo na associação de uma prótese parcial removível de extremidade livre mandibular associada ao implante com sistema de retenção ERA, pelo método dos elementos finitos

Lucas, Liliana Vicente Melo de [UNESP] 18 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-12-18Bitstream added on 2014-06-13T20:06:14Z : No. of bitstreams: 1 lucas_lvm_dr_araca.pdf: 2722998 bytes, checksum: 4598b84f7bad6e641b9c428ccef728d3 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Associação das próteses parciais removíveis de extremidade livre com os implantes osseointegrados é, ainda, uma opção de tratamento pouco explorada na Odontologia reabilitadora moderna. Por isso, o objetivo deste estudo é avaliar, utilizando o método dos elementos finitos bidimensional, a distribuição de tensão e o deslocamento nas estruturas de suporte da prótese parcial removível de extremidade livre (PPREL) associada a um implante osseointegrado de 10,0 x 3,75 mm com sistema ERA de retenção, em diferentes formatos de rebordo alveolar. Para tanto, foram criados oito modelos, os quais, em corte sagital, representam: Modelo A (MA) - uma hemiarcada com rebordo horizontal, sem suporte posterior, com a presença do dente 33 e de uma PPREL convencional, com apoio metálico na incisal do dente 33, em substituição aos dentes 34, 35, 36 e 37; Modelo B (MB) - semelhante ao MA, diferenciando-se deste pela presença de um implante de 3,75 x 10,00 mm com sistema ERA de retenção associado, na região posterior da base da PPREL; Modelo C (MC) - semelhante ao MA, entretanto o rebordo distal apresenta uma conformação ascendente distal; Modelo D (MD) - semelhante ao MC, diferenciando-se deste pela presença do implante com sistema de retenção associado; Modelo E (ME) - semelhante ao MA, entretanto o rebordo distal apresenta uma conformação descendente distal; Modelo F (MF) - semelhante ao ME, diferenciando-se deste pela presença do implante com sistema ERA de retenção; Modelo G (MG) - semelhante ao MA, entretanto o rebordo distal apresenta formato descendente-ascendente; Modelo H (MH) - semelhante ao MG, diferenciando-se deste pela presença do implante com sistema ERA de retenção. Com o auxílio do programa de elementos finitos ANSYS 9.0, os modelos foram carregados com forças verticais de 50 N, em cada ponta de cúspide.... / The association of mandibular distal extension removable artial dentures with an osteointegrated implant is a treatmeat hasn't been fully explored by modern rehabilitation dentistry yet. For this reason, the objective of this study is to evaluate, by means of the bidimensional method of finite elements, the distribution of tension and the displacement on the structures supporting the distal extension removable partial denture (DERPD), associated to a 10.0 x 3.75 mm osteointegrated implant with an ERA retention system, in alveolar ridges of different shapes. For that purpose, eight models were created, representing, from a sagittal perspective: Model A (MA) - a half arch with a horizontal ridge without posterior support, with the presence of the lower left canine, and a conventional DERPD, with metallic support in the incisal aspect of this canine, as replacement for the first and second pre-molars and the first and second molars of the lower left half arch; Model B (MB) - similar to MA, but different because of the presence of a 3.75 x 10.00 mm implant with an associated ERA retention system in the posterior region of the DERPD base; Model C (MC) - similar to MA, however with a distally ascending ridge format; Model D (MD) - similar to MC, but different because there is an implant associated to a retention system; Model E (ME) - similar to MA, however with a distally descending ridge format; Model F (MF) - similar to ME, but different in the sense that there is an implant with an associated ERA retention system; Model G (MG) - similar to MA, however with a distally descending-ascending ridge format; Model H (MH) - similar to MG, but different in the sense that there is an implant with an associated ERA retention system. The finite element program ANSYS 9.0 was used to load the models with vertical forces of 50 N, on each cuspid tip...(Complete abstract, click electronic address below)
135

Influência de pigmentos e opacificadores na estabilidade de cor, dureza, absorção e solubilidade de um silicone facial submetido ao envelhecimento acelerado

Santos, Daniela Micheline dos [UNESP] 27 May 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-05-27Bitstream added on 2014-06-13T19:44:51Z : No. of bitstreams: 1 santos_dm_dr_araca.pdf: 1533021 bytes, checksum: 248d1fb3f8ac9369529ebf0ea03f0654 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O presente estudo teve por objetivo avaliar a influência de dois pigmentos (pó de cerâmica e tinta a óleo) e um opacificador (sulfato de barium) sobre as propriedades físicas de estabilidade de cor, dureza, absorção e solubilidade do silicone facial MDX4-4210, submetido ao envelhecimento acelerado. Para a confecção das amostras, foram utilizadas 2 matrizes metálicas em alumínio, contendo em seu interior 10 compartimentos circulares com 45mm de diâmetro apresentando estes, em uma matriz, uma espessura de 2mm para os testes de estabilidade de cor e dureza e, na outra, 1mm para os ensaios de absorção e solubilidade. Foram confeccionadas 120 amostras, metade para os ensaios de análise cromática e dureza e, a outra metade, para o teste de absorção e solubilidade. As amostras destinadas para cada teste foram distribuídas em seis grupos, incolor (G1), incolor com opacificador (G2), cerâmica (G3), cerâmica com opacificador (G4), óleo (G5), óleo com opacificador (G6). Após a obtenção das amostras, a análise cromática inicial foi verificada por meio da análise visual e da espectrofotometria de reflexão. Os ensaios de dureza foram realizados com auxílio de um durômetro Shore A. Os testes de absorção e solubilidade foram realizados por meio de um dessecador no qual as amostras permaneceram neste ambiente em estufa à temperatura de 37±2°C, sendo pesadas diariamente até obtenção de massa constante (W1); posteriormente as amostras foram submetidas ao envelhecimento seguido de nova pesagem (W2), e nova dessecação com pesagem final (W3). As amostras foram submetidas ao envelhecimento acelerado por 1008 horas, sendo os ensaios realizados nos períodos correspondentes a 252, 504 e 1008 horas. Os dados obtidos foram submetidos à ANOVA e Tukey, com significância de 5%. Pode-se observar pela análise espectrofotométrica que os grupos com opacificador apresentaram melhor... / The aim of this study was to evaluate the influence of two pigments (ceramic powder and oil paint) and one opacifier (barium sulfate) on physical properties of color stability, hardness, absorption and solubility of the facial silicone MDX4-4210 submitted to artificial aging. The replicas were fabricated in two metallic matrixes in aluminum containing 10 circular compartments with 45mm in diameter. One matrix generated specimens with 2mm in thickness for color stability and hardness evaluations while the other matrix, specimens with 1mm in thickness for absorption and solubility tests. The replicas were divided into six groups: colorless (G1), colorless with opacifier (G2), ceramic (G3), ceramic with opacifier (G4), oil (G5) and oil with opacifier (G6). Initial chromatic evaluation was performed by visual analysis and reflection spectrophotometry. The hardness tests were carried out by a Shore A durometer. The evaluations of absorption and solubility were performed through a desiccator to maintain the replicas in a stove at 37±2°C. The specimens were weighed daily until obtaining a constant mass, (W1). Then, the replicas were submitted to aging followed by a new weighing (W2) and drying with final weighing (W3). The replicas were submitted to accelerated aging during 1008 hours with evaluation after 252, 504 and 1008 hours. Data were submitted to statistical analysis by ANOVA and Tukey’s test at 5% level of significance. According to spectrophotometry, the groups with opacifier presented statistically significant better chromatic stability than the other groups. The accelerated aging generated significant chromatic alterations in all groups, except for colorless and oil groups both with opacifier. There was no statistically significant difference among the groups after aging regarding hardness, absorption and solubility. According to the results, it may be concluded that... (Complete abstract, click electronic access below)
136

Analise fotoelastica da distribuição de tensões em dois sistemas de proteses mandibulares sobre implantes : barra distal e solda a laser / Photoelastic analysis of the distribution of the tensions in two systems of mandibular prosthesis over implants : distal bar and laser welding

Salles, Angelo Emilio Barroso de 12 August 2018 (has links)
Orientador: Mauro Antonio de Arruda Nobilo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-12T16:14:35Z (GMT). No. of bitstreams: 1 Salles_AngeloEmilioBarrosode_M.pdf: 10746117 bytes, checksum: 7a6d08147fb33c8d235cc7df5f8be032 (MD5) Previous issue date: 2008 / Resumo: Este estudo avaliou por meio de análise fotoelástica, a distribuição in vitro das tensões geradas na interface "osso/implante" em próteses mandibulares, tipo protocolo, comparando duas técnicas de confecção: Solda a laser e Barra Distal (Neodent, Curitiba - PR) onde não se utiliza infra-estrutura metálica. Foram confeccionadas duas próteses com design similares (uma para cada técnica), sobre uma matriz metálica simulando um arco mandibular edêntulo, onde foram instaladas cinco réplicas de implantes de corpo único (GT- Neodent, Curitiba - PR). A partir de um molde de silicone de duplicação (Silibor - Clássico Artigos Odontológicos Ltda.) foi confeccionado um modelo em resina fotoelástica (Araldite GY279BR - Araltec Produtos Químicos Ltda. Guarulhos - SP) com cinco implantes GT (Neodent, Curitiba - PR) incorporados. Após a instalação de cada prótese sobre o modelo fotoelástico, utilizando 10 N/cm para aperto dos parafusos, foi realizada análise fotoelástica. Em seguida, foi aplicada carga oclusal de 100 N em toda extensão de cada prótese, com auxílio de uma placa metálica posicionada sobre a face oclusal dos dentes, e então realizada nova análise das tensões. Estas análises foram executadas com o auxílio de um polariscópio circular acoplado a uma máquina fotográfica digital (H1 - Sony, Japão), que permitiu a visualização das franjas e registrou através de fotografias digitais o comportamento das mesmas ao redor dos implantes no modelo fotoelástico. De acordo com os resultados, concluiu-se que a técnica utilizando Barra Distal distribuiu melhor, e transmitiu com menos intensidade, após o aperto dos parafusos, as tensões geradas na interface "osso/implantes" do que a técnica utilizando solda a laser. No entanto, ocorreu o inverso após o carregamento oclusal. / Abstract: The aim of this study was to evaluate through photoelastic analysis, the in vitro distribution of the generated tensions in the "bone/ implant" interface in mandibular prostheses, protocol type, comparing two different working techniques: the idealized by Branemark and Distal Bar (Neodent, Curitiba - PR) where framework is not used. Two similar prostheses were made (one for each technique), on a metal matrix simulating an edentulous mandible, where five replications of single body implant were installed (GT-Neodent, Curitiba - PR). From a silicone mold for duplication (Silibor - Classico Artigos Odontológicos Ltda.), a model in photoelastic resin was created (Araldite GY279BR - Araltec Produtos Quimicos Ltda., Guarulhos - SP) with five GT implants (Neodent, Curitiba - PR) embedded. After the installation of each prosthesis on the photoelastic model, using 10 N/cm for tightening the screws, a photoelastic analysis was performed. Then a 100 N occlusion load was applied throughout each prosthesis extension with the help of a metal plate positioned on the occlusal face of the teeth, and then a new analysis of the tensions was conducted. These analyses were performed with the help of a circular polariscope attached to a digital camera (H1 - Sony, Japan), which allowed the visualization of the fringes and recorded by digital photos the behaviour of the implants. According to the results, it was concluded that the Distal Bar technique distributed better, and transmitted with less intensity, after the tightening of the screws, the generated tensions to the system "bone/implants" than the laser welding. However, it happened the opposite after the occlusal load. / Mestrado / Protese Dental / Mestre em Clínica Odontológica
137

Concepção de proteses mioeletricos de membros superiores baseado no estudo fisiologico / Conception of upper limbs myoelectrical prosthesis based on physiological study

Vidal, Tabata 25 February 2008 (has links)
Orientador: Helder Anibal Hermini / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-11T07:22:27Z (GMT). No. of bitstreams: 1 Vidal_Tabata_M.pdf: 5227439 bytes, checksum: 003d20540fa55512408c2b363171f23c (MD5) Previous issue date: 2008 / Resumo: O objetivo deste trabalho foi revisar na literatura os desenvolvimentos da aplicação das tecnologias envolvidas em automação dedicadas às próteses mioelétricas de membros superiores, desde os primeiros trabalhos implementados no período pós-Segunda Guerra Mundial até as soluções tecnológicas atualmente utilizadas. O conceito de prótese mioelétrica envolve a aquisição e tratamento do sinal mioelétrico de um membro residual que é usado para acionar um atuador que ativará a ferramenta terminal. Objetivando a elaboração de uma solução compatível e aplicável harmonicamente ao sistema orgânico, foram realizados estudos da anatomia, da fisiologia articular dos membros superiores, da natureza e características do sinal mioelétrico, além das tecnologias envolvidas para a concepção de protótipos mecatrônicos, tais como técnicas de CAD-CAE-CAM e a geração de circuitos eletrônicos dedicados à coleta e tratamento de sinais mioelétricos. Para validar o desenvolvimento teórico, três protótipos da ferramenta terminal foram confeccionados, sendo testados em nível de bancada / Abstract: The goal of this work was to review the specialized literature for the development of technological applications connected with automation of myoelectrical prosthesis of upper limbs throughout the years, from World War 2 post-war solutions to the technology currently applied. The concept of myoelectrical prosthesis presupposes implies the acquisition and treatment of the myoelectrical signal of a residual limb which is used to start an actuator, which in turn activates the terminal tool. Aiming at encountering a solution that could be both compatible and harmoniously applicable to the human body, the author engaged in studying anatomy, upper limbs articular physiology, the nature and characteristics of the myoelectrical signal in addition to the technologies utilized to conceive mechatronic prototypes, i.e. CAD-CAE-CAM and the creation of dedicated electronic circuits to collect and process the myoelectrical signals. To validate the theoretical foundation of this project, three prototypes of terminal tools were manufactured and bench-tested. / Mestrado / Mecanica dos Sólidos e Projeto Mecanico / Mestre em Engenharia Mecânica
138

Masticatory function in partially edentulous patients after rehabilitation with removable and fixed prosthesis over osseointegrated implants = Função mastigatória de pacientes parcialmente edêntulos após reabilitação com próteses removíveis e fixas sobre implantes osseointegrados / Função mastigatória de pacientes parcialmente edêntulos após reabilitação com próteses removíveis e fixas sobre implantes osseointegrados

Gonçalves, Thais Marques Simek Vega, 1980- 23 October 2013 (has links)
Orientador: Renata Cunha Matheus Rodrigues-Garcia / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T21:43:34Z (GMT). No. of bitstreams: 1 Goncalves_ThaisMarquesSimekVega_D.pdf: 2684657 bytes, checksum: b1b361a499cc2e74dc84aa2b63d2ae75 (MD5) Previous issue date: 2013 / Resumo: Estudos revelam melhora na mastigação após o uso de próteses sobre implantes osseointegrados. Entretanto, poucos são aqueles que avaliam a mastigação de pacientes parcialmente edêntulos, comparando a função mastigatória após a reabilitação por meio de diferentes próteses parciais, o qual foi o objetivo deste ensaio clínico pareado. Para tanto, foram selecionados 12 voluntários (8 gênero feminino, idade média 62.6 ± 7.8 anos), apresentando edentulismo total superior e parcial inferior (classe I de Kennedy), os quais receberam, de forma sequencial, próteses parciais removíveis (PPR), PPR com encaixe implanto-retido (PPRI) e prótese parcial fixa sobre implantes (PPFI). Todos os tratamentos foram realizados na mandíbula e utilizados por 2 meses antes da avaliação mastigatória, enquanto a maxila recebeu uma nova prótese total que foi utilizada durante todo o estudo. A mastigação foi avaliada por meio da mensuração da performance mastigatória (PM), índice de trituração dos alimentos (ITA), força máxima de mordida (FMM), espessura dos músculos masseter e temporal, movimento mastigatório, limiar de deglutição (LD), habilidade mastigatória, estado nutricional, qualidade de vida (QV) e satisfação do paciente. Foi realizada a análise exploratória dos dados e aplicada análise de variância para medidas repetidas seguido de teste de Tukey-Kramer para as comparações múltiplas entre os tratamentos. Todas as análises foram realizadas utilizando SAS software (release 9.1, 2003; SAS Institute Inc., Cary, USA) (p ? 0.05). A PM melhorou consideravelmente após o uso de PPRI e PPFI com aumento de 85% e 87%, respectivamente. Resultados similares foram observados em relação ao ITA e à FMM com aumento (p ? 0.0001) de 91% e 62% no ITA de 79% e 62% na FMM após o uso de PPRI e PPFI, respectivamente. Independente do tipo de prótese, o uso de PPRI e PPFI aumentou a espessura do masseter durante a contração voluntária máxima (p ? 0.0001) e alterou o movimento mastigatório, reduzindo o tempo total do ciclo, bem como a duração das fases de abertura e fechamento (p ? 0.05). A habilidade mastigatória melhorou após o uso da PPRI e PPFI, independente do alimento avaliado. O LD foi alterado pelo tratamento reabilitador, com redução no número de ciclos e tamanho da partícula triturada, sendo os menores valores observados com o uso da PPFI. Houve aumento no consumo de fibras (p = 0.007), cálcio (p = 0.001) e ferro (p = 0.02) após o uso de PPFI, além da redução no consumo de alimentos com altos níveis de colesterol (p = 0.02). A satisfação aumentou (p ? 0.05) e o impacto da saúde oral na QV reduziu, tanto no score geral (p = 0.04) quanto no domínio de dor física (p = 0.02) após o uso da PPFI. A reabilitação de pacientes parcialmente edêntulos com PPRI e PPFI melhorou significativamente a função mastigatória e a magnitude do efeito relacionou-se ao tipo de prótese / Abstract: Studies revealed the masticatory improvement after the use of prosthesis over dental implants. However, few are those who evaluated the chewing of partially edentulous patients, comparing the masticatory function after treatment with different partial dentures, which was the aim of this paired clinical trial. Therefore, 12 volunteers (8 females, mean age 62.6 ± 7.8 years) presenting total edentulism in maxilla and partial edentulism in the mandible (Kennedy class I) were selected and received, in a sequential way, a conventional removable partial dentures (RPD), implant-retained partial dentures (IRPD) and implant fixed partial denture (IFPD). All treatment were assembled in the mandible and used for 2 months, while the edentulous maxilla received a new complete denture which was used throughout the study. Mastication was assessed by measuring masticatory performance (MP), food comminution index (FCI), maximum bite force (MBF), masseter and temporal muscle thickness, chewing movements, swallowing threshold (ST), masticatory ability, nutritional status, quality of life (QOL) and patient satisfaction. Data were analyzed and repeated measures analysis of variance was applied followed by Tukey-Kramer multiple for comparisons between treatments. All analyzes were performed using SAS software (release 9.1, 2003, SAS Institute Inc., Cary, USA) (p ? 0.05). MP greatly improved after IRPD and IFPD use with an increase of 85% and 87% respectively. Similar results were observed in respect to FCI and MBF with an increase (p ? 0.0001) of 91% and 62% in FCI and of 79% and 62% in MBF after the IRPD and IFPD use, respectively. Regardless the prosthesis type, the use of IRPD and IFPD increased the masseter thickness during maximum voluntary clenching (p ? 0.0001) and altered the chewing movements, reducing the total cycle time, as well as the duration of opening and closing phases (p ? 0.05). MA improved after IRPD and IFPD use, irrespectively of the food rated. ST was affected by prosthetic treatment, showing a reduction in the number of chewing cycles and in the size of the comminuted particle, with the lowest values observed after IFPD use. There was a raise in fiber (p = 0.007), calcium (p = 0.001) and iron (p = 0.02) intake after the IFPD use and a reduction in the intake of food with high cholesterol levels (p = 0.02). Patients satisfaction also increased (p ? 0.05) and the impact of oral health on QOL decreased in overall score (p = 0.04) and in the physical pain domain (p = 0.02) after the IFPD use. The rehabilitation of partially edentulous patients with IRPD and IFPD significantly improved masticatory function and the magnitude of the effect was related to the prosthesis type / Doutorado / Protese Dental / Doutora em Clínica Odontológica
139

Kinetik ved løb med dagligdagsprotese og løbespecifikprotese hos transtibial amputerede: Et cross-sectional studie

Grøtner, Katrine, Pham, Huy Hoang January 2020 (has links)
Formål: Formålet med studiet er at undersøge hvordan løb med en dagligdagsprotese og en løbespecifikprotese påvirker kinetik i nedre ekstremiteter hos mennesker med en transtibial-amputation.   Metode: Kinetisk data blev indsamlet ved løbetests, med begge proteser, med et motion capture system og kraftplader i et klinisk ganganalyse lab i Göteborg, Sverige. Deltagere(n=2) udførte løbetests i selvvalgt hastighed, iført refleksive markører. Vertikal GRF, fod progressions vinkel, adducerende/abducerende hofte- og knæmoment udvalgt til videre databehandling.   Resultat: Forskelle i hofte- og knæ adduktions moment og fod progressions vinkel blev observeret mellem de to protesetyper. Momenterne var mindre, når deltagerne løb med den løbespecifikke protese. Forskelle på den amputerede side og den kontralaterale side noteredes ved alle parametre uanset protesetype. Den kontralaterale side havde forøgede værdier sammenlignet med den amputerede side.   Konklusion: Grundet forsøgets størrelse kan vi ikke konkludere, at individer med unilateral amputation i nedre ekstremitet absorberer belastning bedre, når de løber med en løbespecifikprotese fremfor en dagligdagsprotese. / Aim: The aim of this study was to investigate how running with a daily-use prosthesis and a running specific prosthesis affects kinetics in the lower extremities when it comes to people with a transtibial amputation.   Method: Kinetic data was collected through running tests, using both type of prosthesis, with a motion capture system and force plates in a clinical gait lab in Gothenburg, Sweden. Participants (n=2) executed the running tests in a self-selected speed, while wearing reflective markers. Vertical ground reaction force, foot progression angle, hip- and knee moment were selected for data processing.   Results: Differences in hip- and knee adduction moment and foot progression angle were observed between the two types of prostheses. Moments were smaller when participants ran with running-specific prosthesis. Dissimilarity for the amputated side and the contralateral side were noted for all parameters regardless of type of prosthesis. The contralateral side had increased values compared to the amputated side.     Conclusion: Because of the sample size we cannot conclude that individuals with a unilateral lower body amputation absorb load more efficiently when running with a running-specific prosthesis rather than a daily-use prosthesis.
140

Influência do formato do rebordo alveolar na distribuição interna das tensões em prótese parcial removível dento-implantossuportada

Martin Júnior, Manoel [UNESP] 06 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-06Bitstream added on 2014-06-13T18:07:43Z : No. of bitstreams: 1 martinjunior_m_me_araca.pdf: 1987212 bytes, checksum: 7b293d4845e041e9d49b2c3d5d18fcce (MD5) / Universidade Estadual Paulista (UNESP) / Os dados sobre a influência da forma do rebordo alveolar na distribuição interna das tensões na associação da prótese parcial removível de extremidade livre (PPREL) com os implantes osseointegrados são inconclusivos. Assim, o objetivo deste estudo foi avaliar através do método dos elementos finitos (MEF) bi-dimensional, a influência do formato do rebordo alveolar na distribuição interna das tensões. Para isso, foram confeccionados 12 (doze) modelos no programa AutoCAD 2005 (Autodesk Inc, USA), sendo: Modelo A (MA) - hemiarcada com a representação do dente natural 33 e o rebordo edentado para distal; Modelo B (MB) - semelhante ao MA com uma PPREL convencional substituindo os dentes ausentes 34, 35, 36 e 37; Modelo C (MC) - semelhante ao MB, porém com um implante do Sistema Bränemark (3,75 x 10,0 mm) posicionado na região retromolar, sob a base da prótese, conferindo apenas suporte; Modelos A1, A2, A3, A4, B1, B2, B3, B4, C1, C2, C3 e C4 foram baseados nos respectivos modelos: A, B e C, com a identificação numérica seguindo a forma do rebordo alveolar no plano sagital, como descrito: descendente distal (1), côncavo (2), plano (3) e ascendente distal (4). Os modelos foram exportados para o programa de elementos finitos ANSYS 8.0 (Swanson Analysis Systems, Houston, Pa) para a análise numérica. O carregamento foi realizado com forças verticais de 50 N. Os resultados mostraram que máxima tendência ao deslocamento para os rebordos analisados ocorreu de forma semelhante entre os modelos B e C, sendo: descendente distal (B1 - 0,2484 mm e C1- 0,2513 mm), plano (B3 - 0,2415 mm e C3 0,2452 mm), côncavo (B2 - 0,2377 mm e C2 0,2392 mm) e ascendente distal (B4 - 0,2255 mm e C4 - 0,2293 mm); a máxima concentração de tensão nos modelos B apresentou a seguinte ordem: descendente distal (288,77 MPa), côncavo (199,99 Mpa), plano (197,11 MPa) e ascendente distal (185,22 MPa)... . / The data about the influence of the alveolar ridge shape in the stress distribution during the association of a free-end saddle removable partial denture (FERPD) with an osseointegrated implant are inconclusive. Thus, the objective of this study was to evaluate, by bidimensional the finite element analysis (FEA), the influence of the alveolar ridge shape in the stress distribution. For this, 12 (twelve) models were created in the program AutoCAD 2005 (Autodesk Inc, USA), representing: model A (MA) - hemiarch containg only the natural tooth 33 and edentulous space for distal; model B (MB) - similar to MA with a conventional FERPD replaying the absent teeth 34, 35, 36 and 37; model C (MC) - similar to MB, however with an implant of the Sistema Bränemark (3,75 x 10,0 mm) positioned in posterior area, in order to support FERPD base; Models A1, A2, A3, A4, B1, B2, B3, B4, C1, C2, C3 and C4 were based on the respective models: A, B and C, with the numeric identification following the shape in the sagital plane, as described: distal descending (1), concave (2), plan (3) and distal ascendancy (4). The models were exported for the FEA hardware (ANSYS 8.0 Swanson Analysis Systems, Houston, PA) for numeric analysis. The loading were performance with vertical forces of 50 N. The results showed maximum displacement tendency (mm) were between models B and C: distal descending (B1 - 0.2484 mm and C1 - 0.2513 mm), plan (B3 - 0.2415 mm and C3 0.2452 mm), concave (B2 - 0.2377 mm and C2 0.2392 mm) and distal ascendancy (B4 - 0.2255 mm and C4 - 0.2293 mm); the maximum stress concentration for models B were distal descending (288,77 MPa), concave (199,99 MPa), plan (197,11 MPa) and distal ascendancy (185,22 MPa); the model C present an inversion between plan and distal ascending shape: C1 with 395,93 MPa, C2 with 341,49 MPa, C4 with 266,02 MPa and C3 with 219,58 MP... (Complete abstract, click electronic address below).

Page generated in 0.0429 seconds