11

Compliant pediatric prosthetic knee

Mahler, Sebastian 01 June 2007 (has links)
We have designed and examined a compliant knee mechanism that may offer solutions to problems that exist for infants and toddlers who are just learning to walk. Pediatric prosthetic knees on the market today are not well designed for infants and toddlers for various reasons. Children at this age need a prosthetic that is light in weight, durable, and stable during stance. Of the eleven knees on the market for children, all but three are polycentric or four-bar knees, meaning they have multiple points of movement. Polycentric knees are popular designs because they offer the added benefit of stable stance control and increased toe clearance, unfortunately this type of knee is often too heavy for young children to wear comfortably and is not well suited for harsh environments such as sand or water, common places children like to play. The remaining three knees do not offer a stance control feature and are equally vulnerable to harsh environments due to ball bearing hinges. Compliant mechanisms offer several design advantages that may make them suitable in pediatric prosthetic knees -- light weight, less susceptible to harsh environments, polycentric capable, low part count, etc. Unfortunately, they present new challenges that must be dealt with individually. For example compliant mechanisms are typically not well suited in applications that need adjustability. This problem was solved by mixing compliant mechanism design with traditional mechanism design methods. This paper presents a preliminary design concept for a compliant pediatric prosthetic knee. The carbon fiber composite spring steel design was first built and then evaluated using Finite Element Analysis. The prototype's instant center was plotted using the graphical method. From our analysis position, force and stress information was gathered for a deflection up to 120 degrees. The instant centers that were plotted indicate that the knee has good potential in offering adequate stability during stance.
12

Compliant robotic arms for inherently safe physical human-robot interaction

She, Yu January 2018 (has links)
No description available.
13

Compliant Centrifugal Clutches: Design, Analysis, and Testing

Crane, Nathan B. 29 September 2003 (has links) (PDF)
Existing classes of centrifugal clutch concepts were reviewed. The pseudo-rigid-body model (PRBM), rigid-body replacement synthesis, force-deflection analysis, compliance potential evaluation, and compliant concept evaluation were used to develop effective new centrifugal clutch concepts. These methods helped develop and model four novel compliant centrifugal clutch designs, model two existing designs, and identify a concept with excellent potential for low-cost centrifugal clutch applications. This concept, the floating opposing arm (FOA) clutch, doubles the torque capacity metric relative to existing compliant designs. Torque and engagement speed models for this clutch were developed and verified against four prototype clutches. Additional novel designs devel-oped through this work have lower torque capacities, but also show good potential because of other unique characteristics. All of the designs were prototyped and tested to measure their torque-speed relationships.
14

The Pseudo-Rigid-Body Model for Dynamic Predictions of Macro and Micro Compliant Mechanisms

Lyon, Scott Marvin 15 April 2003 (has links) (PDF)
This work discusses the dynamic predictions of compliant mechanisms using the Pseudo-Rigid-Body model (PRBM). In order to improve the number of mechanisms that can be modeled, this research develops and identifies several key concepts in the behavior of beam segments where both ends are fixed to a rigid body (fixed-fixed flexible segments). A model is presented, and several examples are discussed. The dynamic behavior of several compliant segments is predicted using the PRBM and the results are compared to finite element analysis and experimental results. Details are presented as to the transient behavior of a typical uniform rectangular cross section beam. The results of this study are extended and applied to compliant planar mechanisms. It is shown by comparison with finite element analysis and experimental results that the PRBM is a good model of the physical system's dynamic behavior. The method is also demonstrated for use with compliant microelectromechanical (MEMS) systems.
15

The modelling and optimal design of a three degree-of-freedom XYθz micro-motion stage.

Handley, Daniel Charles January 2007 (has links)
This thesis presents an investigation of the modelling and optimal design of a particular 3-degree-of-freedom (DOF) XYθz micro-motion stage. This stage provides micron-scale motion in X and Y directions and a rotation about the Z-axis. Such a stage can be used for applications where positioning of components with micrometre, or even nanometre positioning accuracy is required. Some applications are; the positioning of samples in a scanning-electron-microscope; the positioning of masks in lithography; aligning fibre-optics and lasers; and manipulation of micro-scale objects in micro-biology or micro-systems assembly. The XYθz micro-motion stage investigated in this study uses a particular topology of monolithic compliant mechanism and three stack piezoelectric actuators. The compliant mechanism used is a 3RRR (three revolute-revolute-revolute) parallel compliant mechanism using flexure hinges. This parallel mechanism uses three RRR linkages. Each of the three RRR linkages uses three circular profile flexure hinges. Each flexure hinge provides predominantly rotational motion about one axis. This topology of mechanism has a symmetrical structure and provides numerous advantages that make it appropriate for use in a micro-motion stage. However, as yet this topology of compliant mechanism has only been investigated by a handful of researchers and it has not been used in any commercially developed systems. The design methodology of a stage using the 3RRR compliant mechanism has not been investigated in detail. In this thesis a study is presented that investigates different approaches to model the 3RRR compliant mechanism and also considers the piezo-actuator modelling, to give the complete XYθz micro-motion stage. Three models are presented and compared; the Pseudo-Rigid-Body Model (PRBM); a two-dimensional Finite-Element-Model (2-D FEM); and a third model is developed that is similar to the PRBM, but uses analytical equations to model the multiple degree-of-freedom compliance of the flexure hinges. The models developed are then used in parametric study so that the relationship between design parameters and output behaviour can be understood. An optimal design approach is then presented to develop an XYθz micro-motion stage for a particular application in a Scanning-Electron-Microscope (SEM). Finally experimental validation of the models is presented. The results of this study indicate which modelling approaches are accurate enough to prove useful for design, while also considering which models are computationally simple enough to be efficient and easy to use. The kinematic and dynamic behaviour of the 3RRR compliant mechanism and XYθz micro-motion stage is discussed in detail. This includes; a comprehensive description of the stage workspace, defining reachable and constant-rotation workspace areas; a discussion of actuator coupling; and in depth investigation of the modes of vibration. The results of the parametric study provide useful insight to aid the design of the XYz micro-motion stage and help simplify optimal design. The parametric study also highlights the difference in trends predicted by different modelling methods, which demonstrates the importance of using an appropriate model in design. The experimental validation demonstrates the accuracy of some modelling approaches while highlighting the limited accuracy of others. / http://proxy.library.adelaide.edu.au/login?url= http://library.adelaide.edu.au/cgi-bin/Pwebrecon.cgi?BBID=1272186 / Thesis (Ph.D.) -- University of Adelaide, School of Mechanical Engineering, 2007
16

The modelling and optimal design of a three degree-of-freedom XYθz micro-motion stage.

Handley, Daniel Charles January 2007 (has links)
This thesis presents an investigation of the modelling and optimal design of a particular 3-degree-of-freedom (DOF) XYθz micro-motion stage. This stage provides micron-scale motion in X and Y directions and a rotation about the Z-axis. Such a stage can be used for applications where positioning of components with micrometre, or even nanometre positioning accuracy is required. Some applications are; the positioning of samples in a scanning-electron-microscope; the positioning of masks in lithography; aligning fibre-optics and lasers; and manipulation of micro-scale objects in micro-biology or micro-systems assembly. The XYθz micro-motion stage investigated in this study uses a particular topology of monolithic compliant mechanism and three stack piezoelectric actuators. The compliant mechanism used is a 3RRR (three revolute-revolute-revolute) parallel compliant mechanism using flexure hinges. This parallel mechanism uses three RRR linkages. Each of the three RRR linkages uses three circular profile flexure hinges. Each flexure hinge provides predominantly rotational motion about one axis. This topology of mechanism has a symmetrical structure and provides numerous advantages that make it appropriate for use in a micro-motion stage. However, as yet this topology of compliant mechanism has only been investigated by a handful of researchers and it has not been used in any commercially developed systems. The design methodology of a stage using the 3RRR compliant mechanism has not been investigated in detail. In this thesis a study is presented that investigates different approaches to model the 3RRR compliant mechanism and also considers the piezo-actuator modelling, to give the complete XYθz micro-motion stage. Three models are presented and compared; the Pseudo-Rigid-Body Model (PRBM); a two-dimensional Finite-Element-Model (2-D FEM); and a third model is developed that is similar to the PRBM, but uses analytical equations to model the multiple degree-of-freedom compliance of the flexure hinges. The models developed are then used in parametric study so that the relationship between design parameters and output behaviour can be understood. An optimal design approach is then presented to develop an XYθz micro-motion stage for a particular application in a Scanning-Electron-Microscope (SEM). Finally experimental validation of the models is presented. The results of this study indicate which modelling approaches are accurate enough to prove useful for design, while also considering which models are computationally simple enough to be efficient and easy to use. The kinematic and dynamic behaviour of the 3RRR compliant mechanism and XYθz micro-motion stage is discussed in detail. This includes; a comprehensive description of the stage workspace, defining reachable and constant-rotation workspace areas; a discussion of actuator coupling; and in depth investigation of the modes of vibration. The results of the parametric study provide useful insight to aid the design of the XYz micro-motion stage and help simplify optimal design. The parametric study also highlights the difference in trends predicted by different modelling methods, which demonstrates the importance of using an appropriate model in design. The experimental validation demonstrates the accuracy of some modelling approaches while highlighting the limited accuracy of others. / http://proxy.library.adelaide.edu.au/login?url= http://library.adelaide.edu.au/cgi-bin/Pwebrecon.cgi?BBID=1272186 / Thesis (Ph.D.) -- University of Adelaide, School of Mechanical Engineering, 2007
17

Achieving Complex Motion with Fundamental Components for Lamina Emergent Mechanisms

Winder, Brian Geoffrey 01 March 2008 (has links) (PDF)
Designing mechanical products in a competitive environment can present unique challenges, and designers constantly search for innovative ways to increase efficiency. One way to save space and reduce cost is to use ortho-planar compliant mechanisms which can be made from sheets of material, or lamina emergent mechanisms (LEMs). This thesis presents principles which can be used for designing LEMs. Pop-up paper mechanisms use topologies similar to LEMs, so it is advantageous to study their kinematics. This thesis outlines the use of planar and spherical kinematics to model commonly used pop-up paper mechanisms. A survey of common joint types is given, as well as an overview of common monolithic and layered mechanisms. In addition, it is shown that more complex mechanisms may be created by combining simple mechanisms in various ways. The principles presented are applied to the creation of new pop-up joints and mechanisms, which also may be used for lamina emergent mechanisms. Models of the paper mechanisms presented in Chapter 2 of the thesis are found in the appendix, and the reader is encouraged to print, cut out and assemble them. One challenge associated with spherical and spatial LEM design is creating joints with the desired motion characteristics, especially where complex spatial mechanism topologies are required. Hence, in addition to a study of paper mechanisms, some important considerations for designing joints for LEMs are presented. A technique commonly used in robotics, using serial chains of revolute and prismatic joints to approximate the motion of complex joints, is presented for use in LEMs. Important considerations such as linkage configuration and mechanism prototyping are also discussed. Another challenge in designing LEMs is creating multi-stable mechanisms with the ability to have coplanar links. A method is presented for offsetting the joint axes of a spatial compliant mechanism to introduce multi-stability. A new bistable spatial compliant linkage that uses that technique is introduced. In the interest of facilitating LEM design, the final chapter of this thesis presents a preliminary design method. While similar to traditional methods, this method includes considerations for translating the mechanism topology into a suitable configuration for use with planar layers of material.

Page generated in 0.0578 seconds