• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 127
  • 14
  • 4
  • 1
  • 1
  • 1
  • Tagged with
  • 148
  • 65
  • 46
  • 38
  • 27
  • 23
  • 22
  • 22
  • 20
  • 19
  • 19
  • 19
  • 18
  • 18
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Sistema eletrônico de controle para laser amarelo de aplicação oftalmológica com regime de operação contínuo e micro-pulsado / Electronic control system to yellow laser for ophthalmic applications and continuous or micro second pulse regime

Mota, Alessandro Damiani 30 March 2012 (has links)
Mais recentemente foi proposta uma nova técnica para tratamento de doenças relacionadas à retina humana, utilizando descargas laser na retina com seqüência de pulsos da ordem de 200 \'mü\'s, em substituição ao tratamento convencional que utiliza pulsos longos da ordem de 300 ms. A principal vantagem da nova técnica é a preservação (sem morte celular) do tecido exposto ao laser. Esse trabalho apresenta os mecanismos adotados para o desenvolvimento de um sistema eletrônico de controle de uma cavidade laser em 586 nm, para uso oftalmológico, que objetiva atender o protocolo exigido por essa técnica mais recente. O referido protocolo exige a formação de pulsos rápidos de laser, o que torna vital a velocidade do sistema eletrônico de controle da cavidade laser. Para atender os requisitos do projeto foram implementados dois controladores de corrente em malha fechada PI (Proporcional integrative controller) que trabalham em sincronismo, um controlador de potência óptica em malha fechada PI, e circuitos auxiliares de controle térmico da cavidade laser. Em software foram implementados um PI de potência, com objetivo de tornar a malha de controle estável com o tempo de resposta necessário, e o PI de controle térmico dos elementos da cavidade laser. Os testes realizados do protótipo demonstraram que o sistema de controle atendeu as especificações de projeto, principalmente no que se refere a tempo de resposta do pulso rápido, ponto fundamental na obtenção do protocolo clínico (FastPulse), que esse trabalho objetiva atender. Adicionalmente, o protótipo foi submetido a teste clínico em um paciente, e os resultados demonstraram eficácia no tratamento e ausência de marcas (lesões) na retina. / Recently, scientists have proposed a new technique for treating diseases related to the human retina, which is based on retinal laser discharges using pulse sequence around of 200 \'mü\'s, replacing the conventional treatment using long pulses around of 300 ms. The main advantage of the new technique is the conservation (without cell death) of the area exposed to the laser. This work presents the mechanisms adopted for the development of an electronic control system of a laser cavity at 586 nm for ophthalmic use, which aims to meet the protocol required by this recent technique. The protocol requires the formation of rapid pulses of laser, which makes the electronic control system response velocity of the laser cavity vital to the protocol. To meet the project requirements were implemented two current controllers in closed loop PI (proportional integrative controller) working synchronized, an optical power controller in closed loop PI, and auxiliary circuits for temperature control of the laser cavity. Software were implemented for two controls, a PI power, in order to make the control loop stable with the required response time, and a PI thermal control for elements of the laser cavity. Tests showed that the prototype met the design specifications, especially regarding the response time of rapid pulse, key point in obtaining the clinical protocol (FastPulse), that this work aims to meet. Additionally, the prototype was subjected to clinical trial on a patient, and the results demonstrated efficacy and no visible lesions were noticed on retina.
102

Tomografia de estado quântico via ressonância magnética nuclear através de rotações globais do sistema de spins / Quantum state tomography via nuclear magnetic resonance using global rotations of the spin system

Carvalho Neto, João Teles de 25 May 2007 (has links)
O objetivo principal da presente Tese é expor um método de Tomografia de Estado Quântico desenvolvido para ser aplicado em sistemas de núcleos quadrupolares isolados. O espaço de Hilbert de tais sistemas pode ser usado para processar a informação quântica de um sistema equivalente constituído por vários q-bits. O método proposto baseia-se na aplicação de pulsos de radiofrqüência não-seletivos que possuem a propriedade de promover rotações globais do estado quântico do sistema. Utilizando uma descrição analítica dessas rotações foi possível generalizar o método proposto para núcleos quadrupolares com qualquer número quântico de spin. O método também pode ser adaptado para sistemas de núcleos acoplados, embora para esses casos seja necessário utilizar períodos de evolução sob a hamiltoniana de interação livre para determinar alguns dos elementos da correspondente matriz densidade. Como aplicação do método de Tomografia de Estado Quântico, utilizaram-se núcleos de 23Na dissolvidos em um cristal líquido liotrópico para obter os resultados experimentais das implementações do algoritmo de Deutsch e do algoritmo de busca de Grover, além da medida da dinâmica de relaxação de vários estados pseudo-puros. Também foram realizadas simulações do método proposto para o caso de um sistema quadrupolar de spin 7/2 e para três spins 1/2 homonucleares acoplados. / The main purpose of the present thesis is to propose a Quantum State Tomography method developed to be applied in quadrupolar isolated nuclei systems. The Hilbert space of such systems can be used to process the quantum information of an equivalent system formed by many qubits. The proposed method is based on the application of non-selective radiofrequency pulses that produce global rotations of the system quantum state. Using an analytical description of those rotations, it was possible to generalize the proposed method to quadrupolar nuclei with any spin quantum number. The method can also be adapted to coupled nuclear systems, although in such cases it is necessary the use of evolution periods under the free interaction hamiltonian in order to determine some of the density matrix elements. As an application of the method, 23Na nuclei dissolved in a lyotropic liquid crystal were used to obtain the experimental results of the Deutsch and Grover algorithms, together with the measurement of the relaxation dynamics of some pseudo-pure states. Simulations of the proposed method applied to the quadrupolar spin 7/2 nucleus and to three homonuclear coupled spin 1/2 were also obtained.
103

Determinação simultânea de propifenazona, paracetamol e cafeína utilizando eletrodo de diamante dopado com boro

Silva, Weberson Pereira da 16 February 2017 (has links)
Fundação de Amparo a Pesquisa do Estado de Minas Gerais / No presente trabalho investigou-se o desenvolvimento de novos procedimentos analíticos para a determinação simultânea de paracetamol (PAR), propifenazona (PRO) e cafeína (CAF) em formulações farmacêuticas. Três métodos foram desenvolvidos usando as técnicas de voltametria de onda quadrada (SWV) e amperometria de múltiplos pulsos (MPA) e diamante dopado com boro (BDD) como eletrodo de trabalho. Empregando a SWV, duas estratégias de análise foram desenvolvidas: (I) uso de uma célula eletroquímica convencional (modo estacionário) e o método de adição de padrão; (II) uso de análise por injeção em batelada com detecção por voltametria de onda quadrada (BIA-SWV) e o método de calibração externa. Os métodos propostos foram desenvolvidos usando como eletrólito de suporte H2SO4 0,1 mol L-1 e os parâmetros otimizados da SWV foram: potencial de condicionamento: -1,5 V durante 20 s; frequência: 60 s-1; amplitude: 50 mV e incremento de potencial: 4 mV. No método proposto empregando BIA-SWV, o volume e a velocidade de injeção otimizados foram de 100 μL e 28 μL s-1, respectivamente. Um terceiro método proposto para determinação simultânea de PAR, PRO e CAF, o procedimento de análise por injeção em batelada com detecção por amperometria de múltiplos pulsos (BIA-MPA) foi empregado. Três pulsos de potenciais foram selecionados para realização da análise: +0,90 V /50 ms: apenas o PAR foi oxidado sem a interferência dos outros dois compostos; +1,20 V /50 ms: oxidação do PAR e da PRO livre da interferência da CAF; +1,60 V /50 ms: oxidação dos três compostos (PAR, PRO e CAF). A seletividade na detecção da PRO e CAF foi obtida mediante subtração de correntes entre os amperogramas adquiridos nos potenciais selecionados e o uso de fatores de correção (FCs). Todos os procedimentos de análise desenvolvidos mostraram-se estáveis (DPR < 4,1%) e lineares (r > 0,997). O método empregando uma célula eletroquímica convencional apresentou frequência analítica de 20 análises h-1 e limites de detecção de 0,005, 0,009 e 0,006 mg L-1 para PAR, PRO e CAF, respectivamente. Os métodos BIA-SWV e BIA-MPA apresentaram frequência analítica muito superior: 80 e 75 análises h-1, respectivamente. Os limites de detecção foram de 0,3, 0,2 e 0,3 mg L-1 (BIA-SWV) e 0,2, 0,3 e 0,1 mg L-1 (BIA-MPA) para PAR, PRO e CAF, respectivamente. / In this work we investigated the development of new analytical procedures for simultaneous determination of paracetamol (PAR), propyphenazone (PRO) and caffeine (CAF) in pharmaceutical formulations. Three methods was developed using of Square wave voltammetry (SWV), multiple pulse amperometry (MPA) and boron doped diamond (BDD) with work electrode. Employing SWV, two analysis strategies were developed (I) Use of a conventional electrochemical cell (stationary mode) and the standard addition method; (II) use of batch injection analysis with detection by square wave voltammetry (BIA-SWV) and external calibration method. The proposed methods were developed using H2SO4 0.1 mol L-1 as supporting electrolyte and optimized parameters of the SWV: Conditioning potential: -1.5 V during 20 s; frequency: 60 s-1; amplitude: 50 mV and step potential: 4 mV. In the proposed method using BIA-SWV, volume and speed of optimized injection were 100 μL e 28 μL s-1, respectively. On the third method proposed for simultaneous determination of the PAR, PRO and CAF, the batch injection analysis procedure with multiple pulse amperometry detection (BIA-MPA) was employed. Three potentials pulses were selected for the analysis: +0.90 V/50 ms: only PAR was oxidized without the interference of the other two compounds; +1.20 V/50 ms: oxidation PAR and PRO without the interference of the CAF; +1.60 V/50 ms: oxidation of the three compounds (PAR, PRO and CAF). The selectivity in the detection of PRO and CAF was obtained by subtracting currents between the amperograms acquired in the selected potentials and the use of correction factors (CFs). All developed analysis procedures remained stable (RSD < 4.1%) and linear (r > 0.997). The method using a conventional electrochemical cell showed an analytical frequency of 20 analysis h-1 and limits of detection of 0.005, 0.009, and 0.006 mg L-1 for PAR, PRO, and CAF, respectively. The BIA-SWV and BIA-MPA methods presented higher analytical frequency: 80 and 75 analysis h-1, respectively. The limits of detection were 0.3, 0.2, and 0.3 mg L-1 (BIA-SWV) and 0.2, 0.3, and 0.1 mg L-1 (BIA-MPA) for PAR, PRO and CAF, respectively. / Dissertação (Mestrado)
104

Determina??o de sildenafila (Viagra?) e carbamazepina em formula??es farmac?uticas por amperometria de m?ltiplos pulsos em sistema FIA / Determination of sildenafil (Viagra?) and carbamazepine in pharmaceutical formulations by multiple pulses amperometry in FIA system

Lopes J?nior, Ant?nio Carlos Vieira 27 July 2012 (has links)
Submitted by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2015-02-19T13:03:28Z No. of bitstreams: 5 carlos.pdf: 2538374 bytes, checksum: bc72a52cc529db58b3cf890bd9a41042 (MD5) license_url: 52 bytes, checksum: 3d480ae6c91e310daba2020f8787d6f9 (MD5) license_text: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) license.txt: 2110 bytes, checksum: b4c884761e4c6c296ab2179d378436d4 (MD5) / Approved for entry into archive by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2015-02-20T09:21:34Z (GMT) No. of bitstreams: 5 license.txt: 2110 bytes, checksum: b4c884761e4c6c296ab2179d378436d4 (MD5) carlos.pdf: 2538374 bytes, checksum: bc72a52cc529db58b3cf890bd9a41042 (MD5) license_url: 52 bytes, checksum: 3d480ae6c91e310daba2020f8787d6f9 (MD5) license_text: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Made available in DSpace on 2015-02-20T09:21:34Z (GMT). No. of bitstreams: 5 license.txt: 2110 bytes, checksum: b4c884761e4c6c296ab2179d378436d4 (MD5) carlos.pdf: 2538374 bytes, checksum: bc72a52cc529db58b3cf890bd9a41042 (MD5) license_url: 52 bytes, checksum: 3d480ae6c91e310daba2020f8787d6f9 (MD5) license_text: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Previous issue date: 2013-02-21 / O presente trabalho apresenta m?todos simples, r?pidos e de baixo custo para determina??o de citrato de sildenafila (CS) e carbamazepina (CBZ) em formula??es farmac?uticas atrav?s da detec??o amperom?trica de m?ltiplos pulsos (MPA) em sistema de an?lise por inje??o em fluxo (FIA) utilizando como eletrodo de trabalho o diamante dopado com boro (DDB). O m?todo para determina??o de CS consiste na aplica??o de tr?s pulsos de potencial em sequ?ncia. Os pulsos de potencial de 1,6 V e 1,9 V s?o utilizados para detec??o eletroqu?mica do f?rmaco e um terceiro pulso de potencial (1,0 V) para promover a limpeza e reativa??o da superf?cie do eletrodo de DDB. Os limites de detec??o (LD) obtido nas condi??es estabelecidas est?o na ordem de 10 nmol L-1 para ambos os potenciais de detec??o. O desvio padr?o relativo das respostas de 10 inje??es consecutivas de CS na concentra??o de 4,5x10-5 mol L-1 foi de 0,1 e 0,2% para os pulsos de potencial de detec??o de 1,9 V e 1,6 V, respectivamente. Os estudos de adi??o e recupera??o de CS padr?o foram realizados em todas as amostras farmac?uticas apresentando recupera??o, em todos os casos, pr?ximo de 100%. Os resultados de doseamento dos medicamentos realizados a partir do m?todo proposto foram validados por metodologia cromatogr?fica. Para a CBZ foram propostas duas vertentes anal?ticas, uma voltada para determina??o do ativo em amostras farmac?uticas e outra para detec??o do f?rmaco em fluidos biol?gicos. Alguns par?metros foram semelhantes em ambos os procedimentos, s?o eles: eletr?lito suporte (?cido sulf?rico 0,2 mol L-1), vaz?o (3,0 mL min-1), volume de amostragem (150 ?L), potencial de limpeza (-1,4 V) e tempo de aplica??o deste potencial (600 ms). Al?m destes par?metros, para an?lise do f?rmaco em produto farmac?utico, foram utilizados para detec??o os pulsos de potenciais 1,6 e -1,2V, sendo aplicados por 150 e 30 ms, respectivamente. Nestas condi??es, foram obtidas as seguintes faixas lineares de trabalho: 0,6 a 40,0 ?mol L-1 para o pulso de potencial de 1,6 V e 0,4 a 20,0 ?mol L-1 para o pulso de potencial de -1,2 V. Para determina??o de CBZ em fluido biol?gico adotou-se como sistema de detec??o o pulso de potencial de 1,6 V aplicado por 800 ms (gerador) e o pulso de potencial de -1,2 V aplicado por 30 ms (detector). Para este pulso de potencial foi obtida faixa linear de trabalho de 0,02 a 1,0 ?mol L-1 e LD de 1,78 nmol L-1. Os estudos de adi??o e recupera??o de CBZ padr?o em amostras farmac?uticas e urina apresentaram resultados pr?ximos de 100%. Os resultados do ensaio de doseamento de medicamentos, realizados pelo m?todo proposto, foram validados por meio de metodologia oficial. Este trabalho apresenta, pela primeira vez, m?todos para determina??o de CS e CBZ em formula??es farmac?uticas atrav?s da detec??o MPA em sistema FIA. A associa??o desta t?cnica ao eletrodo de trabalho de DDB permitiu o desenvolvimento de m?todos de elevada sensibilidade, seletividade, rapidez e reprodutibilidade, demonstrando not?vel potencialidade para aplica??o no controle de qualidade de rotina de CS e CBZ em laborat?rios farmac?uticos e farm?cias de manipula??o. / Disserta??o (Mestrado) ? Programa de P?s-Gradua??o em Qu?mica, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2012. / ABSTRACT The present work presents simple, fast and low-cost methods for determination of sildenafil citrate (CS) and carbamazepine (CBZ) in pharmaceutical formulations using flow injection analysis (FIA) with multiple pulse amperometric (MPA) detection on the boron-doped diamond (DDB) working electrode. The method for the CS determination consists of the application of three sequential potential pulses as function of the time. SC is detected at 1.6 V and 1.9 V by two different irreversible oxidation processes. The third potential pulse (1.0 V) is applied for the regeneration (cleaning) of the electrode (boron-doped diamond) surface. The limit of detection (LD) in an order of 10 nmol L-1 was reached with a standard deviation of less than 0.2 % (n = 10) for 4.5 x 10-5 mol L-1 CS. The analytical frequency was calculated in 86 injections per hour. The addition-recovery studies in all the samples were around 100% and the results were validated by chromatographic methods. For the CBZ determination, two analytic conditions were proposed, one used for determination of a drug in pharmaceutical samples and other for detection the active ingredient in biological fluids. Some parameters were similar in both procedures, they are: supporting electrolyte (sulfuric acid 0.2 mol L-1), flow (3.0 ml min-1), sampling volume (150 ?L), regeneration potential pulse (-1.4 V) and time of application of this potential (600 ms). In addition to these parameters, for analysis of pharmaceutical drug, were used to detect it the potential pulses 1.6 V and -1.2 V, being applied for 150 and 30 ms, respectively. These conditions provided linear range of 0.6 to 40.0 ?mol L -1 for potential pulse 1.6 V and 0.4 to 20.0 ?mol L-1 for potential pulse -1.2 V. For the CBZ determination in biological fluid adopted as detection system the potential pulse of 1.6 V applied for 800 ms (generator) and potential pulse of -1.2 V applied for 30 ms (detector). For this potential pulse the linear range was of 0.02 to 1.0 ?mol L-1 and the LD was 1.78 nmol L-1. The addition-recovery studies in all the samples were around 100 % and the results were validated by official method. This work presents for the first time methods of SC and CBZ determination in pharmaceutical formulations utilizing MPA detection coupled to an FIA system. This technique, associated with a BDD working electrode, provided a sensitive, selective, fast and highly reproducible methods. Thus, the proposed methods may be an extremely attractive alternative for routine large and small-scale CS and CBZ analysis.
105

Determina??o de colchicina em formula??es farmac?uticas e urina por amperometria de m?ltiplos pulsos em sistema FIA usando eletrodo de diamante dopado com boro / determination of colchicine in pharmaceutical formulations and urine by multiple-pulse amperometric in FIA system using boron-doped diamond electrode

Moreira, D?bora Aparecida Rocha 23 July 2015 (has links)
?rea de concentra??o: Qu?mica Anal?tica. / Submitted by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2016-01-06T17:04:45Z No. of bitstreams: 2 license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) debora_aparecida_rocha_moreira.pdf: 1871735 bytes, checksum: 71403ce90b6b32e48e7c18b312d74e32 (MD5) / Approved for entry into archive by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2016-01-07T11:59:23Z (GMT) No. of bitstreams: 2 license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) debora_aparecida_rocha_moreira.pdf: 1871735 bytes, checksum: 71403ce90b6b32e48e7c18b312d74e32 (MD5) / Made available in DSpace on 2016-01-07T11:59:23Z (GMT). No. of bitstreams: 2 license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) debora_aparecida_rocha_moreira.pdf: 1871735 bytes, checksum: 71403ce90b6b32e48e7c18b312d74e32 (MD5) Previous issue date: 2015 / A colchicina (CO) ? um medicamento utilizado no tratamento da artrite gotosa com a??o anti-inflamat?ria. Este medicamento pertence a uma classe de compostos chamados de baixo ?ndice terap?utico, cuja dose t?xica ? muito pr?xima da dose terap?utica. Assim, a determina??o de CO em formula??es farmac?uticas e em fluidos biol?gicos ? de maior import?ncia para o controle de qualidade nos estudos farmac?uticos e farmacol?gicos na condu??o da elimina??o da droga. Neste contexto, o presente trabalho apresenta m?todos simples, r?pidos e de baixos custos para determina??o de CO em formula??es farmac?uticas e urina por amperometria de m?ltiplos pulsos (MPA) com an?lise de inje??o em fluxo, sistema (FIA), usando eletrodo de diamante dopado com boro (BDD). O estudo foi realizado em diferentes eletr?litos, Britton-Robinson de pH que variou de 2 a 12, solu??o de hidr?xido de s?dio e ?cido sulf?rico, ambos na concentra??o de 0,1 mol L-1. As melhores condi??es para o eletr?lito de suporte foi em ?cido sulf?rico 0,1 mol L-1, em que a CO apresentou processos de oxida??o em 1,20 e 1,41 V e uma redu??o de detec??o em -0,9 V. MPA foi baseado na aplica??o potencial dos dois impulsos de: (1) para a oxida??o de CO e (2) para a redu??o do produto gerado, o qual foi utilizado para a determina??o das amostras de f?rmacos. Assim, no sistema FIA-MPA foram aplicados pulsos potenciais de 1,7 V / 500 ms e -1,1V / 30 ms. Os demais par?metros foram otimizados como: taxa de fluxo e volume da amostra em 4,5 mL min-1 e 330 ?L, respectivamente. Sob estas condi??es, foi obtida duas faixas lineares de 0,1 ? 2,0 ? mol L-1 e 20 x 10-5 a 500 x 10-4 mol L-1 com coeficiente de correla??o linear de 0,992 e 0,998, respectivamente. O limite de detec??o obtido foi de 2,14 x 10-8 mol L-1 para o CO. O desvio padr?o relativo de inje??es consecutivas de 10 respostas sobre a concentra??o de CO de 1,0 x 10-4 mol L-1 foi de 1,28% em -1.1 V. O sistema foi validado em compara??o com o m?todo oficial (HPLC / UV). Os resultados das recupera??es obtidas por meio do m?todo proposto para ambas as amostras foram pr?ximo a 100%. Portanto, o m?todo proposto por FIA-MPA utilizando eletrodo BDD pode ser aplicado com sucesso para a determina??o de CO em amostras de urina e farmac?uticas, com vantagens em rela??o ao m?todo oficial e outros m?todos descritos na literatura. / Disserta??o (Mestrado) ? Programa de P?s-Gradua??o em Qu?mica, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2015. / ABSTRACT The Colchicine (CO) is a drug used in treatment of gouty arthritis with anti-inflammatory action. This medication belongs to a class of compounds called low therapeutic index, whose toxic dose is much close to the therapeutic dose. Thus, the determination of CO in pharmaceutical formulations and in biological fluids is of the utmost importance for the quality control in pharmaceutical and pharmacological studies in conducting the elimination of the drug. In this context, the present work presents simple, fast and low-cost methods for determination of CO in pharmaceutical formulations and urine by multiple-pulse amperometric (MPA) with flow-injection analysis (FIA) system using boron-doped diamond (BDD) electrode. Study was carried out in different electrolytes, Britton-Robinson buffer pH ranging from 2 to 12, sodium hydroxide solution and sulfuric acid, both at a concentration of 0.1 mol L-1. The best conditions for the support electrolyte was sulfuric acid 0.1 mol L-1, where the CO showed oxidation processes at 1.20 and 1.41 V and one of reduction at -0.9 V. MPA detection was based on the potential application of two pulses: (1) for oxidation of CO and (2) for reduction in the generated product, which was used for the determination of the drug in the samples. Thus, in the FIA-MPA system were applied potential pulses of 1.7 V / 500ms and -1.1V / 30ms. The other parameters were optimized as: flow rate and sample volume in 4.5 mL min-1 and 330 ?L, respectively. Under these conditions, it was achieved two linear ranges of 0.1 to 2.0 ?mol L-1 and of 20 to 500 ?mol L-1 with great linear correlation coefficient for both ranges 0.992 and 0.998 respectively. The limit of detection obtained was of 2.14 x 10-8 mol L-1 for CO. Relative standard deviation of injections of 10 consecutive responses on CO concentration of 1.0 x 10-4 mol L-1 was 1.28% at -1.1 V. The system was validated in comparison with the official method (HPLC / UV). The results of the recoveries obtained through the proposed method for both samples are around 100%. Therefore, the method proposed by FIA-MPA using BDD electrode can be successfully applied for the determination of CO in pharmaceutical and urine samples, with advantages in relationship official method and others methods described in the literature.
106

Determina??o de Verapamil e Oxcarbazepina em amostras de urina e formula??es farmac?uticas por amperometria pulsada em FIA

Lima, Amanda Barbosa January 2016 (has links)
Data de aprova??o ausente. / Submitted by Jos? Henrique Henrique (jose.neves@ufvjm.edu.br) on 2017-03-24T17:42:56Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) amanda_barbosa_lima.pdf: 1709527 bytes, checksum: 4fddb4fdbd889c4c7f3a82be7a0edabe (MD5) / Approved for entry into archive by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2017-04-20T19:16:33Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) amanda_barbosa_lima.pdf: 1709527 bytes, checksum: 4fddb4fdbd889c4c7f3a82be7a0edabe (MD5) / Made available in DSpace on 2017-04-20T19:16:33Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) amanda_barbosa_lima.pdf: 1709527 bytes, checksum: 4fddb4fdbd889c4c7f3a82be7a0edabe (MD5) Previous issue date: 2016 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior (CAPES) / Verapamil (VP) e Oxcarbazepina (OX) s?o f?rmacos de baixo ?ndice terap?utico que necessitam de rigoroso controle de qualidade em formula??es farmac?uticas, bem como de an?lises em fluidos biol?gicos para estudos farmacol?gicos de elimina??o dessas drogas. Neste sentido, o desenvolvimento de m?todos simples, r?pidos e de baixo custo ? de extrema import?ncia para quantifica??o desses f?rmacos nessas amostras. Deste modo, o presente trabalho apresenta um m?todo eletroanal?tico em fluxo para determinar VP e OX tanto em formula??es farmac?uticas, quanto em amostras de urina. A t?cnica eletroqu?mica utilizada para quantifica??o foi a Amperometria de M?ltiplos Pulsos (MPA) acoplada a um sistema de an?lise por inje??o em fluxo (FIA), utilizando o diamante dopado com boro (BDD). Foram aplicados tr?s pulsos de potencial pela MPA para determina??o do VP em meio de ?cido sulf?rico 0,1 mol L-1, sendo +1,6 V para a oxida??o e, posteriormente, +0,2 V para redu??o do produto gerado do VP e +0,1 V para a limpeza do eletrodo de BDD. Para a determina??o de OX, tamb?m foram otimizados tr?s pulsos de potencial em meio de tamp?o acetato 0,1 mol L-1 (pH 4,0), sendo + 1,7 V para a oxida??o da OX e gera??o do produto que foi reduzido em -1,1 V e -1,3 V para a limpeza do eletrodo de BDD. Em ambos os casos, apenas o sinal obtido nos pulsos de potencial de redu??o foram utilizados para quantifica??o dos f?rmacos. As faixas lineares de trabalho obtidas para quantifica??o do VP e da OX foram de 0,8 a 40,0 ?mol L-1 (R= 0,9976) e 2,0 a 80,0 ?mol L-1 (R= 0,9989), respectivamente. Os limites de detec??o foram calculados em 0,16 ?mol L-1 para VP e 0,42 ?mol L-1 para OX. Uma boa repetibilidade foi obtida para 10 an?lises consecutivas desses f?rmacos, com desvio padr?o relativo de 2,2% para VP e 0,94 % para OX. Os estudos de adi??o e recupera??o do VP e OX em amostras farmac?uticas e urina apresentaram resultados pr?ximos a 100% e o doseamento do VP foi validado pela metodologia oficial. Altas frequ?ncias anal?ticas foram alcan?adas pelo sistema FIA com 45 e 65 determina??es por hora de VP e OX, respectivamente, usando al?as de amostragem inferiores a 200 ?L e vaz?es de 3,5 mLmin-1. An?lises desses f?rmacos em amostras de urina mostraram que ? poss?vel determin?-los mesmo na presen?a de altas concentra??es de ?cido asc?rbico e ?cido ?rico. Portanto, o m?todo proposto mostrou-se como alternativa simples e r?pida para quantifica??o desses f?rmacos em formula??es farmac?uticas e urina. / Disserta??o (Mestrado) ? Programa de P?s-Gradua??o em Qu?mica, Universidade Federal dos Vales do Jequitinhonha e Mucuri, [2016]. / Verapamil (VP) and Oxcarbazepine (OX) are drugs of narrow therapeutic index that require strict quality control in pharmaceutical formulations and analysis in biological fluids for pharmacological studies of elimination of these drugs. In this sense, the development of simple, fast and low-cost methods is very important to quantify these drugs in pharmaceutical samples. Therefore, this work presents a electroanalytical method in flow for determining VP and OX in pharmaceutical formulations and human urine samples. The electrochemical technique used for quantification was performed by multiple pulses amperometry (MPA) coupled to a flow injection analysis system (FIA), using boron-doped diamond (BDD) as working electrode. Were applied three potential pulses by MPA for the determination of VP in sulfuric acid 0.1 mol L-1: (1) +1.6 V for oxidation of VP, (2) +0.2 V for reduction of the generated product of VP in the fisrt potential pulse, (3) +0.1 V for cleaning of the BDD electrode surface. The determination of OX also was performed by MPA in three potential pulses in 0.1 mol L-1 acetate buffer (pH 4.0): (1) +1.7 V for oxidation of OX and generation of the product that it was reduced at (2) -1.1 V, and (3) -1.3 V for cleaning of the BDD electrode surface. In both cases, only the signal obtained in the reduction potential pulses were used for quantification of drugs. The linear ranges of work obtained for quantitation of VP and OX were 0.8 to 40.0 ?mol L-1 (R = 0.9976) and 2.0 to 80.0 ?mol L-1 (R = 0, 9989), respectively. The detection limits were calculated to be 0.16 ?mol L-1 for VP and 0.42 ?mol L-1 for OX. Good repeatabilities were obtained for 10 consecutives injections of these drugs, with relative standard deviation of 2.2% for VP and 0.94% for OX. The addition and recovery studies for VP and OX in pharmaceutical and urine samples were close to 100% and determination of VP was validated by the official methodology. High analytical frequencies were achieved by FIA system of 45 and 65 determinations per hour for VP and OX, respectively, using sampling handles less than 200 ?L and flow rate of 3.5 mLmin-1. The analysis of these drugs in urine showed that it is possible to determine this sample even in the presence of high concentrations of ascorbic acid and uric acid. Therefore, the present method by MPA-FIA proved to be a quick and easy alternative to quantify VP and OX in pharmaceutical formulations and urine.
107

Uso de luz quantizada para controle e medida em sistemas atômicos e moleculares

Santos, Jader Pereira dos January 2015 (has links)
Orientador: Prof. Dr.Fernando Luis Semião da Silva / Tese (doutorado) - Universidade Federal do ABC, Programa de Pós-Graduação em Física, 2015. / A presente tese de doutorado tem como principal objetivo empregar luz quantizada para o controle e medida em sistemas complexos como em um conjunto de cromóforos, e em um condensado de Bose-Einstein. Em especial, desenvolvemos formalismos de pulsos e equações mestras aplicáveis a esses sistemas e utilizamos teoria de estimativa quântica para determinar quantidades atômicas relevantes de maneira indireta (medindo propriedades da luz). Também empregamos técnicas variadas para obtenção de equações mestras para estudar diferentes problemas envolvendo interação de luz quântica com matéria. Em um caso, obtivemos uma equação mestra microscópica para o estudo de dois sistemas de dois níveis acoplados no espaço livre, e mostramos como a equação mestra microscópica desse sistema se distingue de equações fenomenológicas para o mesmo. Por fim, também discutimos a obtenção de uma equação mestra para o estudo de transferência de emaranhamento entre o campo eletromagnético quantizado e complexos Fenna-Matthews-Olson localizados em cavidades óticas distintas. / The main aim of the present Ph.D. thesis is to employ quantized light to control and measurement of complex systems such as a set of chromophores and a Bose- Einstein condensate in a double well. Specifically, we develop a formalism for pulses and master equations that can be applied to those systems and use quantum estimation theory to get information on relevant parameters in atomic system in a indirect way (measuring light properties). We also employ varied techniques for the obtention of master equations to study different problems involving the interaction of quantum light and matter. We obtained a microscopic master equation for the study of two coupled two-level systems in the free space, and we showed how the microscopic master equation of this system distinguish from the phenomenological ones. Finally, we also discuss the obtention of a master equation for the study of the transference of entanglement between the quantized electromagnetic field and the Fenna-Matthews-Olson complex localized in distinct optical cavities.
108

Eletrodo de diamante dopado com boro para a determinação voltamétrica/amperométrica de antihelmínticos e anti-hipertensivos / Boron doped diamond electrode for the voltametric/ amperometric determination of anthelmintic and antihypertensive drugs

Lourenção, Bruna Cláudia 27 June 2014 (has links)
Made available in DSpace on 2016-06-02T20:34:53Z (GMT). No. of bitstreams: 1 6134.pdf: 6629660 bytes, checksum: a8afd4d15c98e0427e0d70f440a39deb (MD5) Previous issue date: 2014-06-27 / Universidade Federal de Minas Gerais / In this work it was developed, firstly, one method for determination of anthelmintic albendazole (ABZ) using differential pulse voltammetry (DPV) and the boron doped diamond (BDD) electrode catholically pretreated (BDD-CPT). The corresponding analytical curve showed linear response in the concentration range from 0.08 to 8.36 ^mol L-1 with detection limit (LD) of 0.06 ^mol L-1. The proposed method was applied in the determination of ABZ in three pharmaceutical formulations with similar results those obtained using a comparative method. The second part of this work it was to develop two electroanalytical procedures using the amperometry technique coupled to a flow injection analysis system (FIA) for the individual determination of two anthelmintic, the ivermectin (IVM) and levamisole (LVM), where it was used the BDD electrode anodically pretreated (BDD-APT) for LVM and BDD-CPT for IVM. Good linear ranges were obtained for the respective analytical curves with values of 0.60 to 50.0 ^mol L-1 for IVM and 0.01 to 6.00 ^mol L 1 for LVM with LD of 0.30 ^mol L 1 and 1.0 nmol L 1, respectively. These analytes were determined in samples of commercial pharmaceutical formulations and synthetic urine and the results obtained are in agreement with the results obtained using two comparative methods (one for each analyte). The analytical frequencies for each method were 48 and 56 determinations per hour for IVM and LVM, respectively. Another procedure was developed for simultaneous determination of two anthelmintics LVM and albendazole sulfoxide (ABZ-SO) in synthetic urine samples using a FIA system with multiple pulses amperometry (MPA) detection and the BDD-APT electrode. This method was applied for directly determination of ABZ-SO and for indirectly determination of LVM. The employed sequence of dual-potential waveform as a function of time, previously optimized, were Edet1 = +1.40 V / ms 200 (pulse potential at which occurs only ABZ-SO oxidation) and Edet2 = 1.90 V / 200 ms (pulse potential at which the oxidation of both anthelmintic, ABZ-SO and LVM, occurs). The analytical curves showed linearity from 2.00 to 100.0 ^mol L-1 (ABZ-SO) and 0.03 to 1.00 ^mol L-1 (LVM), with LD of 1.00 ^mol L-1 and 6.0 nmol L-1 for ABZ-SO and LVM, respectively. Samples of synthetic urine doped with two different concentrations of ABZ-SO and LVM presented recoveries from 93.3 to 100%. The procedure was simple, accurate and fast, with an analytical frequency of 53 samples per hour. In the last one procedure it was developed a method for simultaneous determination of hydrochlorothiazide (HTZ) and enalapril (ENP) (antihypertensives) using a FIA-MPA system and BDD-CPT electrode. The FIA-MPA method was also proposed based on the direct determination of HTZ and indirect of ENP. The sequence application of the pulses as a function of time, were, Edet1 = +1.50 V / ms 150 (pulse potential at which HTZ occurs) and Edet2 = +1.80 V / ms 150 (pulse potential at which oxidation of both analytes (HTZ and ENP) occurs). The analytical curves presented linearity from 0.40 to 8.00 ^mol L -1 to HTZ and from 0.03 to 1.00 ^mol L-1 to HTZ and LD obtained for HTZ and ENP were 0.20 and 0.01 ^mol L-1, respectively. It was analysed three pharmaceutical commercial samples containing both analytes and the results obtained using the FIA-MPA method are in agreement with those obtained using a comparative method (HPLC) with a confidence level of 95%. The procedure was simple and fast, with an analytical frequency of 89 samples per hour. / Neste trabalho de doutorado desenvolveu-se, primeiramente, um método para determinação do anti-helmíntico albendazol (ABZ) utilizando-se voltametria de pulso diferencial (DPV) e o eletrodo de diamante dopado com boro (BDD) pré-tratado catodicamente (BDD-CPT). A curva analítica obtida apresentou resposta linear de 0,08 a 8,36 ^mol L-1 com um LD de 0,06 ^mol L-1. O método foi aplicado na determinação de ABZ em três formulações farmacêuticas com resultados similares aos obtidos empregando-se um método comparativo. A segunda etapa do trabalho teve como objetivo o desenvolvimento de dois procedimentos eletroanalíticos utilizando um sistema de análise por injeção em fluxo (FIA) e detecção amperométrica para a determinação individual de dois anti-helmíticos, a ivermectina (IVM) e o levamisol (LVM), sendo empregado o BDD pré-tratado anodicamente (BDD-APT) para o LVM e o BDD-CPT, para a IVM. As correspondentes curvas analíticas apresentaram boas linearidades nas faixas de concentrações de 0,60 a 50,0 ^mol L-1 (IVM) e 0,01 a 6,00 ^mol L-1 (LVM), com LDs iguais a 0,30 ^mol L-1 e 1,0 nmol L-1, respectivamente. Estes analitos foram determinados em amostras comerciais de formulações farmacêuticas e amostras de urina sintética sendo os resultados obtidos concordantes com os resultados obtidos empregando-se dois métodos comparativos (um para cada analito). A frequência analítica para cada método foi de 48 e 56 determinações por hora para IVM e LVM, respectivamente. Outro procedimento desenvolvido foi a determinação simultânea de dois anti-helmínticos, LVM e sulfóxido de albendazol (ABZ-SO), em amostras de urina sintética utilizando um sistema FIA com detecção por amperometria de múltiplos pulsos (MPA) empregando-se um eletrodo de BDD-APT. O método proposto foi baseado na determinação direta do ABZ-SO e indireta da LVM. A sequência de aplicação dos pulsos em função do tempo, previamente otimizada, foi, Edet1 = +1,40 V / 200 ms (pulso de potencial no qual ocorre a oxidação apenas de ABZ-SO) e Edet2 = +1,90 V /200 ms (pulso de potencial no qual ocorre a oxidação de ambos os anti-helmínticos ABZ-SO e LVM). As curvas analíticas obtidas apresentaram linearidades de 2.00 a 100,0 ^mol L1 (ABZ-SO) e 0,03 a 1,00 ^mol L1 (LVM), com LDs de 1.00^mol L-1 e 6,0 nmol L-1 para ABZ-SO e LVM, respectivamente. Amostras de urina sintética dopadas com ABZ-SO e LVM em duas diferentes concentrações apresentaram recuperações de 93,3 a 100 %. O procedimento desenvolvido mostrou-se simples, preciso e rápido, com uma frequência analítica de 53 determinações por hora. No último procedimento desenvolveu-se um método para a determinação simultânea de hidroclorotiazida (HTZ) e o enalapril (ENP) (anti-hipertensivos) utilizando-se um sistema FIA-MPA e o eletrodo de BDD-CPT. O método FIA-MPA proposto também foi baseado na determinação direta da HTZ e indireta do ENP. A sequência de aplicação dos pulsos em função do tempo utilizada foi, Edet1 = +1,50V / 150 ms (pulso de potencial no qual ocorre a oxidação apenas do HTZ) e Edet2 = +1,80V / 150 ms (pulso de potencial no qual ocorre a oxidação de ambos os analitos (HTZ e ENP)). As curvas analíticas obtidas apresentaram linearidades de 0,40 a 8,00 ^mol L-1 para o HTZ e de 0,03 a 1,00 ^mol L-1 para o ENP e os LDs obtidos para HTZ e ENP foram de 0,20 ^mol L 1 e 0,01 ^mol L 1, respectivamente. Foram analisadas três amostras comerciais farmacêuticas contendo os dois analitos e os resultados obtidos empregando-se o método FIA-FIA-MPA estão em concordância com aqueles obtidos empregando-se um método comparativo (HPLC) em um nível de confiança de 95%. O procedimento desenvolvido mostrou-se simples e rápido, com uma frequência analítica de 89 determinações por hora.
109

Desenvolvimento de procedimentos eletroanalíticos para a determinação simultânea de analgésicos em formulações farmacêuticas e fluidos biológicos empregando o eletrodo de diamante dopado com boro

Santos, Anderson Martin dos 30 July 2015 (has links)
Submitted by Alison Vanceto (alison-vanceto@hotmail.com) on 2016-09-19T13:08:42Z No. of bitstreams: 1 DissAMS.pdf: 9742960 bytes, checksum: 9f8e053fcda7ed507c68927b7c6c5533 (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2016-09-21T18:19:00Z (GMT) No. of bitstreams: 1 DissAMS.pdf: 9742960 bytes, checksum: 9f8e053fcda7ed507c68927b7c6c5533 (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2016-09-21T18:19:07Z (GMT) No. of bitstreams: 1 DissAMS.pdf: 9742960 bytes, checksum: 9f8e053fcda7ed507c68927b7c6c5533 (MD5) / Made available in DSpace on 2016-09-21T18:19:16Z (GMT). No. of bitstreams: 1 DissAMS.pdf: 9742960 bytes, checksum: 9f8e053fcda7ed507c68927b7c6c5533 (MD5) Previous issue date: 2015-07-30 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / In this master dissertation, electroanalytical procedures for the simultaneous determination of analgesics paracetamol (PAR) and codeine (COD) and, PAR and tramadol (TRA) in pharmaceutical samples and biological fluids using a cathodically pretreated boron-doped diamond electrode (BDDE) were developed. In the first procedure, the square-wave voltammetry (SWV) was employed for the simultaneous determination of PAR and COD, using as supporting electrolyte 0.2 mol L−1 acetate buffer (pH 4.0), and the analytical curves were linear in the concentration range from 0.2 to 95.8 μmol L−1 for PAR and from 0.2 to 95.8 μmol L−1 for COD, with detection limits (LODs) of 0.018 μmol L−1 and 0.014 μmol L−1, respectively. The second procedure developed for the simultaneous determination of PAR and COD was based on a flow injection analysis with multiple pulses amperometric detection (FIA-MPA), using as transport solution a 0.05 mol L−1 H2SO4 solution. The potential pulse application sequence in function of time was 950 mV / 200 ms (potential where only the PAR oxidation occurs) and 1400 mV / 100 ms (potential where both analytes suffers oxidation (PAR and COD)). The obtained analytical curves show linearity from 0.08 to 100.0 μmol L−1 for PAR and 0.05 to 10.0 μmol L−1 for COD, with LODs of 0.030 e 0.035 μmol L−1 for PAR and COD, respectively. The analytical frequency was estimated as being 90 determinations h−1. After, an electroanalytical procedure using FIA–MPA it was developed a simultaneous determination of PAR and TRA. The potential pulse application sequence in function of time was 850 mV / 200 ms (potential where only occurs the PAR oxidation) and 1600 mV / 100 ms (potential where both analytes suffers oxidation). The obtained analytical curves show linearities between 1.0 to 100.0 μmol L−1 and 0.08 to 10.0 μmol L−1 for PAR and TRA, respectively, and the LOD was 0.030 μmol L−1 for PAR and 0.040 μmol L−1 for TRA. Finally, all developed procedures were employed for the simultaneous determination of these compounds (PAR + COD e PAR + TRA) in pharmaceutical samples, where the obtained results agree with those results obtained using a comparative method (HPLC – High-performance liquid chromatography). These compounds were simultaneously analyzed in synthetic biological fluids (urine and human serum) by addiction and recuperation method, where the recuperations obtained ranged from 90.8 to 108%. / Neste trabalho de mestrado foram desenvolvidos procedimentos eletroanalíticos para a determinação simultânea dos analgésicos paracetamol (PAR) e codeína (COD) e de PAR e tramadol (TRA) em amostras farmacêuticas e fluidos biológicos utilizando-se o eletrodo de diamante dopado com boro (BDDE) prétratado catodicamente. Para o primeiro procedimento, empregou-se a voltametria de onda quadrada (SWV) para a determinação simultânea de PAR e COD em tampão acetato 0,2 mol L−1 (pH 4,0) como eletrólito suporte, obtendo-se curvas analíticas lineares nos intervalos de concentração de 0,2 a 95,8 μmol L−1 para PAR e de 0,4 a 9,6 μmol L−1 para COD e limites de detecção (LDs) de 0,018 e de 0,014 μmol L−1 respectivamente para o PAR e COD. O segundo procedimento desenvolvido para a determinação simultânea dos analgésicos PAR e COD foi por análise por injeção em fluxo com detecção amperométrica de múltiplos pulsos (FIA–MPA) em solução transportadora de H2SO4 0,05 mol L−1. A sequência de aplicação dos pulsos em função do tempo foi de 950 mV / 200 ms (pulso de potencial no qual ocorre a oxidação apenas do PAR) e de 1400 mV / 100 ms (pulso de potencial no qual ocorre a oxidação de ambos os analitos (PAR e COD)). As curvas analíticas obtidas apresentaram linearidades de 0,08 a 100,0 μmol L−1 para PAR e de 0,05 a 10,0 μmol L−1 para COD e os LDs foram de 0,030 e 0,035 μmol L−1 para PAR e COD, respectivamente. A frequência analítica obtida foi de 90 determinações h−1. O terceiro procedimento foi desenvolvido empregando-se FIA–MPA para a determinação simultânea de PAR e TRA. Uma sequência de aplicação dos pulsos de potencial em função do tempo foram de 850 mV / 200 ms (pulso de potencial no qual ocorre a oxidação apenas de PAR) e de 1600 mV / 100 ms (pulso de potencial no qual ocorre a oxidação de PAR e TRA). As curvas analíticas obtidas apresentaram linearidades de 1,0 a 100,0 μmol L−1 e de 0,08 a 10,0 μmol L−1 para PAR e TRA, respectivamente, com LDs de 0,030 μmol L−1 para o PAR e de 0,040 μmol L−1 para o TRA. Finalmente, todos os procedimentos desenvolvidos foram empregados para a determinação simultânea destes compostos (PAR + COD e PAR + TRA) em amostras farmacêuticas, sendo os resultados obtidos concordantes com os resultados obtidos empregando-se o método comparativo (HPLC – cromatografia líquida de alta eficiência). Estes analgésicos também foram determinados simultaneamente em fluidos biológicos sintéticos (urina e soro humano) pelo método de adição e recuperação, sendo obtidas recuperações entre 90,8 a 108%.
110

Modelos epidêmicos SIR, contínuos e discretos, e estratégias de vacinação / SIR epidemic models, continuous and discrete, and Vaccination strategies

Almeida, Priscila Roque de 21 February 2014 (has links)
Made available in DSpace on 2015-03-26T13:45:37Z (GMT). No. of bitstreams: 1 texto completo.pdf: 877652 bytes, checksum: f2e3fa6c671a58cfbde6e8941666e966 (MD5) Previous issue date: 2014-02-21 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The main Objective Of this Work is to study and discretize the epidemic SIR model (Susceptible-Infected-Recovered) developed by Kermack and MCKendrick in 1927 [11], between its Consider the simple models With Vital dynamics and Constant and Vaccination strategies pulses, as a method Of epidemic ControL The study of the stability of Continuous-time models With pulse Vaccination is done by means of the Floquet theory. Already the rnethod Of ñnite difference appro- Ximation is used to forward discretize Continuous systems and the analysis On the stability of the new systems found is displayed The theoretical results are Conñrmed by numerical simulations. / O Objetivo principal desde trabalho é estudar e discretizar os modelos epidêmi- COS SIR (Suscetíveis-Infectados-Recuperados) desenvolvidos por MCKendrick e Kermack em 1927, [11], entre eles Consideramos os modelos simples Com dinâmica Vital e Com estratégias de Vacinação Constante e em pulsos, Como método de Con- trole epidêmico. O estudo da estabilidade dos modelos em tempo Contínuos Com Vacinação em pulsos é feito por meio, da Teoria de Floquet. Já 0 rnétodo de aproximação de diferenças ñnitas para frente é utilizado para discretizar os siste- mas Contínuos e é apresentada a análise sobre a estabilidade dos novos sistemas encontrados. Os resultados teóricos são Conñrmados por simulações numéricas.

Page generated in 0.0677 seconds