• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • 13
  • 9
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 47
  • 47
  • 33
  • 24
  • 20
  • 18
  • 18
  • 14
  • 14
  • 12
  • 10
  • 9
  • 9
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Análise dos mecanismos resistentes e das similaridades de efeitos da adição de fibras de aço na resistência e na ductilidade à punção de lajes-cogumelo e ao cisalhamento de vigas de concreto. / Analysis of resistant mechanisms and similarities of the addition effect of steel fibers on strength and ductility to both the punching shear of flat slabs and the shear of concrete beams.

Holanda, Kristiane Mattar Accetti 02 October 2002 (has links)
Um dos principais problemas das lajes-cogumelo refere-se à ruína por puncionamento da ligação laje-pilar. Esta forma de ruína deve ser evitada, proporcionando-se às lajes as melhores condições para o desenvolvimento de mecanismos de escoamento das armaduras e de ruína por flexão, antes da ocorrência da ruína por cisalhamento. A introdução de fibras de aço em elementos de concreto submetidos a solicitações tangenciais proporciona melhoria de desempenho, seja pelo aumento da capacidade resistente, seja pela alteração da forma de ruína. Pretende-se contribuir com o avanço do conhecimento sobre o assunto, explorando aspectos como a análise das similaridades dos efeitos da adição de fibras de aço na resistência e na ductilidade de lajes-cogumelo à punção, com aqueles que se observam no cisalhamento de vigas prismáticas análogas. Abordam-se os casos de ligações laje-pilar interno sem armadura de punção, variando-se a resistência do concreto, a taxa e o tipo de fibra utilizado. A partir dos resultados experimentais, verificou-se que existe uma similaridade de comportamento estrutural entre esses dois elementos e concluiu-se que é possível utilizar ensaios de cisalhamento em vigas prismáticas para se obter indicadores a serem utilizados nos ensaios de punção de lajes. Foi efetuada uma análise da adaptabilidade de modelos teóricos existentes sobre cisalhamento em vigas e punção em lajes, com vistas à consideração do efeito da adição de fibras de aço ao concreto. Com base nesses modelos, foram estabelecidos critérios quantitativos para avaliação da resistência e da ductilidade das ligações laje-pilar. / One of the main problems of flat slabs concerns the punching shear failure of the slab-column connection. This form of failure must be avoided, providing flat slabs with the best conditions for the development of yielding mechanisms of the flexural reinforcement before the occurrence of shear failure. The addition of steel fibers to concrete elements subjected to tangential stress provides performance improvement, by either the resistant capacity increase or the failure mode alteration. It is intended to contribute to the advance of the subject knowledge, by exploring aspects as the analysis of similarities of the steel fiber addition effects on both strength and ductility of flat slabs to punching shear with those observed in the shear of analogous prismatic beams. The cases approached include internal slab-column connections without shear reinforcement, and the variables investigated included concrete strength, fiber volume and type of steel fiber. From the experimental results, it was possible to verify that there exists a similarity of structural behavior between these two elements and the shear tests in prismatic beams can be used to get indicators to be utilized in punching shear tests of flat slabs. An adaptability analysis of the existing theoretical models on shear in beams and punching shear in flat slabs was carried out in order to consider the steel fibers addition effect on the concrete. Based on these models, quantitative criteria for the evaluation of both strength and ductility of the slab-column connections were established.
22

Punção em lajes lisas de concreto armado com furo adjacente ao pilar e transferência de momento / Punching Shear In Reinforced Flat Slabs with Hole Adjacent to the Column and Moment Transfer

OLIVEIRA, Diorgenes Carvalho de 17 June 2011 (has links)
Made available in DSpace on 2014-07-29T15:03:34Z (GMT). No. of bitstreams: 1 Dissertacao Diorgenes C de Oliveira.pdf: 4985818 bytes, checksum: 3bb65a23267322ba684300f2b7486ab1 (MD5) Previous issue date: 2011-06-17 / The structural behavior and the ultimate punching shear resistance of internal reinforced concrete flat slab-column connections, with one hole adjacent to the column, with or without flexural moment transfer of the slab to the column was investigated. Main variables were: the existence whether or not hole, flexural reinforcement layout and ratio, the direction and sense of the moment transferred and the eccentricity of the load (M (moment transferred to column) / V (shear)) ratio at the connection - 0,50 m or 0,25 m. Seven internal slab-column joining were tested and ultimate loads, cracking, deflections, concrete and reinforcement strains were analyzed. The existence of hole adjacent to the smaller column dimension, the hole dimension, flexural reinforcement rate and placing, the variation of relation Mu/Vu in function of the load, and, than, of eccentricity of the load, influenced the slabs behavior and rupture load. These influences were quantified. Test results were compared with the estimations from CEB-FIP/MC1990, EC2/2004, ACI-318:2005 and NBR 6118:2003. ACI and EC2 presented most conservative estimates, although have presented some non conservative estimates. Brazilian NBR, even though being partly based in EC2, presented smaller conservative estimates and more non conservative estimates. A modification on all codes is proposed for taking in account the moment caused by the eccentricity at the critical perimeter for slabs with holes. / São investigados o comportamento estrutural e a resistência última à punção de ligações laje-pilar de regiões internas das lajes lisas, com um furo adjacente ao pilar, e com ou sem transferência de momento fletor da laje ao pilar. As principais variáveis foram: a existência ou não de furo, a taxa e a distribuição da armadura de flexão, a direção e o sentido do momento transferido e a excentricidade de carga (relação M(momento transferido ao pilar)/V(força cortante)) na ligação, igual a 0,50 m ou 0,25 m. Foram ensaiadas 7 (sete) ligações internas laje-pilar e analisados os resultados das cargas últimas, fissuração, deslocamento vertical, deformações das armaduras de flexão e do concreto. A existência de furo adjacente ao menor lado do pilar, a taxa e a distribuição da armadura de flexão, a variação da relação Mu/Vu em função do carregamento, e, por conseguinte, da excentricidade, influenciaram o comportamento e a carga de ruptura das lajes. Essas influências foram quantificadas. Os resultados experimentais foram comparados com os estimados pelas normas: CEB-FIP/MC1990, EC2/2004, ACI-318:2005 e NBR 6118:2003. O ACI e o EC2 apresentaram estimativas mais conservadoras, embora tenham apresentado algumas estimativas contra a segurança. A NBR 6118:2003, apesar de baseada em parte no EC2, apresentou estimativas menos conservadoras e com um número maior de estimativas contra a segurança. Recomenda-se que todas as normas passem a considerar o momento causado pela excentricidade do perímetro crítico em lajes com furos e, neste sentido, foram apresentadas propostas de modificações para todas as normas estudadas.
23

Análise dos mecanismos resistentes e das similaridades de efeitos da adição de fibras de aço na resistência e na ductilidade à punção de lajes-cogumelo e ao cisalhamento de vigas de concreto. / Analysis of resistant mechanisms and similarities of the addition effect of steel fibers on strength and ductility to both the punching shear of flat slabs and the shear of concrete beams.

Kristiane Mattar Accetti Holanda 02 October 2002 (has links)
Um dos principais problemas das lajes-cogumelo refere-se à ruína por puncionamento da ligação laje-pilar. Esta forma de ruína deve ser evitada, proporcionando-se às lajes as melhores condições para o desenvolvimento de mecanismos de escoamento das armaduras e de ruína por flexão, antes da ocorrência da ruína por cisalhamento. A introdução de fibras de aço em elementos de concreto submetidos a solicitações tangenciais proporciona melhoria de desempenho, seja pelo aumento da capacidade resistente, seja pela alteração da forma de ruína. Pretende-se contribuir com o avanço do conhecimento sobre o assunto, explorando aspectos como a análise das similaridades dos efeitos da adição de fibras de aço na resistência e na ductilidade de lajes-cogumelo à punção, com aqueles que se observam no cisalhamento de vigas prismáticas análogas. Abordam-se os casos de ligações laje-pilar interno sem armadura de punção, variando-se a resistência do concreto, a taxa e o tipo de fibra utilizado. A partir dos resultados experimentais, verificou-se que existe uma similaridade de comportamento estrutural entre esses dois elementos e concluiu-se que é possível utilizar ensaios de cisalhamento em vigas prismáticas para se obter indicadores a serem utilizados nos ensaios de punção de lajes. Foi efetuada uma análise da adaptabilidade de modelos teóricos existentes sobre cisalhamento em vigas e punção em lajes, com vistas à consideração do efeito da adição de fibras de aço ao concreto. Com base nesses modelos, foram estabelecidos critérios quantitativos para avaliação da resistência e da ductilidade das ligações laje-pilar. / One of the main problems of flat slabs concerns the punching shear failure of the slab-column connection. This form of failure must be avoided, providing flat slabs with the best conditions for the development of yielding mechanisms of the flexural reinforcement before the occurrence of shear failure. The addition of steel fibers to concrete elements subjected to tangential stress provides performance improvement, by either the resistant capacity increase or the failure mode alteration. It is intended to contribute to the advance of the subject knowledge, by exploring aspects as the analysis of similarities of the steel fiber addition effects on both strength and ductility of flat slabs to punching shear with those observed in the shear of analogous prismatic beams. The cases approached include internal slab-column connections without shear reinforcement, and the variables investigated included concrete strength, fiber volume and type of steel fiber. From the experimental results, it was possible to verify that there exists a similarity of structural behavior between these two elements and the shear tests in prismatic beams can be used to get indicators to be utilized in punching shear tests of flat slabs. An adaptability analysis of the existing theoretical models on shear in beams and punching shear in flat slabs was carried out in order to consider the steel fibers addition effect on the concrete. Based on these models, quantitative criteria for the evaluation of both strength and ductility of the slab-column connections were established.
24

Estudio numérico parametrizado del punzonamiento en losas de hormigón armado. Evaluación del refuerzo estructural

Navarro Menargues, Miguel 06 September 2018 (has links)
En el presente trabajo se aborda la tesis “Estudio paramétrico con FEM del refuerzo a punzonamiento de losas de hormigón armado”. Se trata de todo lo relacionado con el fenómeno resistente de punzonamiento en estructuras, especialmente en forjados construidos mediante hormigón armado. Se trata de cuatro apartados bien diferenciados. En este, el primero, se desarrolla la síntesis de la tesis, donde se marcan unos objetivos, seguido de una explicación detallada y descripción de este fenómeno mediante su estado del arte, que abarca el grueso de éste primer apartado, en el cual se describen, entre otros aspectos, las diferentes patologías producidas por el punzonamiento y casos de sucesos catastróficos que provocaron, la historia de los forjados y los principales estudios llevados a cabo sobre este fenómeno, y acabando con las principales resultados y conclusiones de la tesis. Después, el segundo y tercer apartado contienen los artículos publicados y no publicados, respectivamente, por capítulos. Por último, se desarrollan las conclusiones en el último y cuarto apartado.
25

Comparison of Punching Shear Design Provisions for Flat Slabs

Aalto, Jonatan, Neuman, Elisabeth January 2017 (has links)
Abstract A new generation of EN 1992-1-1 (2004) also known as Eurocode 2 is under development and currently there is a set of proposed provisions regarding section 6.4 about punching shear, PT1prEN 1992-1-1(2017). It was of interest to compare the proposal with the current punching shear design provisions. The aim of this master thesis was to compare the punching shear resistance obtained in accordance with both design codes. Furthermore the eect of some parameters on the resistance was to be compared. It was also of interest to evaluate the userfriendliness of the proposal. In order to meet the aim, a case study of a real  at slab with drop panels was performed together with a parametric study of a pure ctive  at slab. The parametric study was performed for inner, edge and corner columns in the cases prestressed, without and with shear reinforcement. It was concluded that the distance av from the column axis to the contra  exural location has a big in uence on the punching shear resistance. The factor ddg considering concrete type and aggregate properties also has a big impact on the resistance. The simplied estimation of av according to 6.4.3(2) in PT1prEN 1992-1-1 (2017) may be inaccurate in some cases. The length b0 of the control perimeter has a larger eect on the resistance in EN 1992-1-1 (2004) than in PT1prEN 1992-1-1 (2017). In PT1prEN 1992-1-1 (2017), studs located outside the second row has no impact on the resistance. The tensioning force in a prestressed  at slab has a larger in uence on the resistance in PT1prEN 1992-1-1 (2017) than in EN 1992-1-1 (2004). Furthermore, the reinforcement ratio is increased by the tendons, and thus aect the resistance in PT1prEN 1992-1-1 (2017). Clearer provisions for the denition of the support strip bs for corners and ends of walls are needed in PT1prEN 1992-1-1 (2017). It may be questionable if the reduction of the perimeter for a large supported area in accordance with 6.4.2(4) in PT1prEN 1992-1-1 (2017) underestimates the resistance v in some cases. Considering the work-load with PT1prEN 1992-1-1 (2017), more parameters are included. However, they may not require that much eort to obtain. Keywords: Punching shear, resistance, concrete,  at slab, design provisions, Eurocode 2, case study, parametric study, shear reinforcement, prestressed vi
26

Shear strength of structural elements in high performance fibre reinforced concrete (HPFRC)

Moreillon, Lionel 19 March 2013 (has links) (PDF)
For members and flat slabs without shear reinforcement, the shear and punching shear strength are often the determining design criteria. These failure modes are characterized by a fragile behaviour implying possible partial or total collapse of the structure. Despite extensive research in this field, shear and punching shear in reinforced and prestressed concrete structures, remain complex phenomena so much that the current approach is often empirical or simplified. The ability of Steel Fibre Reinforced Concrete (SFRC) to reduce shear reinforcement in reinforced and prestressed concrete members and slabs,or even eliminate it, is supported by several experimental studies. However its practical application remains marginal mainly due to the lack of standard, procedures and rules adapted to its performance. The stationary processes in precast industry offer optimal possibilities for using high performance cementitious materials such as Self Compacting Concrete (SCC) and High Strength Concrete (HSC). For the author, the combination of High Performance Concrete and steel fibres is the following step in the development and the optimization of this industry. The High Performance Fibre Reinforced Concrete (HPFRC) stands between conventional SFRC and Ultra-High Performance Fibre Reinforced Concrete (UHPFRC). The HPFRC exhibiting a good strength/cost ratio is, thus, an alternative of UHPFRC for precast elements. The principal aim of this work was to analyse the shear and punching shear behaviour of HPFRC and UHPFRC structures without transversal reinforcement and to propose recommendations and design models adapted for practitioners. Several experimental studies on structural elements, i.e. beams and slabs, were undertaken for this purpose. Firstly, an original experimental campaign was performed on pre-tensioned members in HPFRC. A total number of six shear-critical beams of a 3.6 m span each, and two full scale beams of a 12 m span each, were tested in order to evaluate the shear and flexural strength. The principal parameter between the specimens was the fibres (...)
27

Resistência e ductilidade das ligações laje-pilar em lajes-cogumelo de concreto de alta resistência armado com fibras de aço e armadura transversal de pinos / Resistance and ductiliy of slab-column connections on high strength concrete flat slabs with steel fibers and shear reinforcement

Azevedo, Aline Passos de 22 April 1999 (has links)
Neste trabalho analisa-se a resistência à punção e a ductilidade das ligações laje-pilar em doze modelos de lajes-cogumelo de concreto armado, nas quais se efetuam combinações de emprego de concreto de alta resistência, diferentes volumes de fibras de aço e uso de armadura transversal na forma de conectores de aço tipo pino. Todas as lajes são quadradas com 1160 mm de lado e 100 mm de espessura. A armadura de flexão foi composta de barras de aço de 10 mm espaçadas de tal forma a resistir a um momento fletor único em ambas direções. Os conectores, quando utilizados, foram dispostos radialmente e compostos de barras de aço de 6.6 mm soldadas a segmentos de ferro chato nas duas extremidades. Para avaliar a capacidade resistente dos modelos de ligação laje-pilar e observar o ganho de ductilidade que as fibras proporcionam, foram ensaiados segmentos-de-laje, os quais representam uma faixa destes modelos de ligação laje-pilar. Foi utilizado um sistema de ensaio dotado de atuador hidráulico servo-controlado, programado para ensaio com deformação controlada e aquisição contínua dos dados, o que permitiu a avaliação do comportamento pós-pico de resistência e a realização de medições de resistência residual. Várias hipóteses de cálculo foram utilizadas para avaliar a resistência última das ligações laje-pilar. Empregou-se um critério de classificação para caracterizar o tipo de ruptura em: punção ou flexão predominante ou uma combinação de punção-flexão. Constatou-se que o emprego de concreto de alta resistência, juntamente com armadura transversal, aumenta substancialmente a resistência da ligação laje-pilar, e quando combinado com fibras de aço, consegue-se um considerável aumento da ductilidade. / This work analyses the punching shear resistance and ductility of slab-column connections on twelve concrete flat slab models. The model characteristics resulted from combinations of the application of high or ordinary strength concrete, different steel fiber volume fractions and use or not of shear reinforcement. All the slabs are square with 1,160 mm of side and 100 mm of thickness. The main flexural reinforcement was composed of 10 mm steel bars spaced in such a way to resist to the same bending moment in both directions. When used, the shear reinforcement of steel studs were disposed in radial directions and consisted of 6.6 mm steel bars welded to flat steel segments in their ends. To evaluate the resistant capacity of slab-column connection models and to observe the ductility that the fibers provide, they were rehearsed segments-of-slab, which represents a strip of these slab-column connection models. A testing system with a servo-controlled hydraulic jack was used and it was programmed for a controlled deformation test and continuous data acquisition. This method allowed the evaluation of the post-peak strength behavior and the measurement of residual resistance forces. Several calculations hypotheses were used to evaluate the ultimate strength of the slab-column connections. A classification criterium was applied to characterize the failure type as: predominant punching or flexure or a combination of punching-flexure. It was verified that the application of high strength concrete, together with shear reinforcement, increases substantially the slab-column connection strength, and, when combined with steel fibers, a considerable ductility increase is achieved.
28

Punção em lajes-cogumelo de concreto de alta resistência reforçado com fibras de aço / Punching shear in high-strength concrete flat slabs reinforced with steel fibre

Zambrana Vargas, Elioth Neyl 16 June 1997 (has links)
Neste trabalho investiga-se o comportamento resistente de lajes-cogumelo de concreto armado, analisando-se as possibilidades de melhoria de desempenho com relação ao fenômeno de punção, pelo emprego de concreto de alta resistência, pelo reforço com fibras de aço e pelo uso de armaduras transversais de combate à punção, através de ensaios de modelos de lajes-cogumelo quadradas que representam a ligação laje-pilar para o caso do pilar interno. Apresenta-se também uma revisão de conhecimentos sobre as lajes-cogumelo, o seu comportamento estrutural com ênfase no fenômeno da punção, e os principais conceitos sobre os concretos de alta resistência e os compósitos constituídos de matriz de cimento reforçada com fibras. Doze modelos de laje-cogumelo foram ensaiados com diferentes combinações de concreto de alta resistência, concreto de resistência convencional, armadura transversal e volume de fibras (0%, 0,75% e 1,5%). Um acréscimo significativo de resistência à punção foi observado, devido ao uso de concreto de alta resistência e à adição de fibras. A combinação de concreto de alta resistência com 1,5% de volume de fibras e armadura transversal proporcionaram o dobro de aumento na resistência à punção em relação ao modelo de concreto convencional sem armadura transversal e sem adição de fibras. A adição de fibras é a suposta responsável por cerca de 50% de acréscimo de resistência e o aumento da ductilidade. Outras comparações incluindo as previsões teóricas (Texto Base da NB1/94, CEB/90, AGI 318/89 e EUROCODE N.2) são comentadas. / This work investigates the behavior of reinforced concrete flat slabs, analysing the possibility of performance improvement, in relation to punching shear phenomenon, regarding to the use of high strength concrete, the addition of steel fibres and the use of transversal steel reinforcement against punching shear, through tests of flat slab square models that represent the slab-column connection, for the case of an interior column. lt introduce a revision of knowledge of flat slabs, their structural behavior with emphasis on the punching shear phenomenon, and the main concepts about high strength concretes and the composites made of cement matrix reinforced with fibres. Twelve flat slab models were tested in different combinations of high strength concrete, ordinary strength, shear reinforcement and steel fibre volume fraction (0%, 0,75% e 1,5%). A significant increase in the punching shear strength was observed, either due to the use of high strength and the addition of steel fibres. The combination of high strength concrete with 1,5% fibre volume fraction and shear reinforcement provide twice the punching shear resistance of an ordinary concrete strength model without shear reinforcement and without fibre. Fibre addition is supposed to be responsible by about 50% of the resistance improvement and the increase of ductility. Other comparisons including theoretical previsions (Texto Base da NB1/94, CEB/90, ACI 318/89 e EUROCODE N.2) are commented.
29

Punching Shear Behaviour of Thick Reinforced Concrete Slabs

Netopilik, Robert J. 26 November 2012 (has links)
Experiments were conducted to investigate the punching shear behaviour of thick slabs with identical spans and depths, subjected to monotonic point load conditions. Variables included: reinforcement ratio, column size, and reinforcement size. Analytical studies conducted as part of this thesis indicate that the current CSA A23.3 and the ACI 318 can be unconservative for thick slabs with low reinforcement ratios. The new fib Model Code provisions for punching offer an effective method for determining the full load-rotation behaviour of a slab up to failure, including accurate failure predictions. A summary of the background of current design procedures and standards will be presented, and a comparison between the different design equations and theories will be given. Based on the findings of this project, it is proposed that the provisions accepted by the fib Model Code should be considered for implementation in the CSA and ACI standards.
30

Punching Shear Behaviour of Thick Reinforced Concrete Slabs

Netopilik, Robert J. 26 November 2012 (has links)
Experiments were conducted to investigate the punching shear behaviour of thick slabs with identical spans and depths, subjected to monotonic point load conditions. Variables included: reinforcement ratio, column size, and reinforcement size. Analytical studies conducted as part of this thesis indicate that the current CSA A23.3 and the ACI 318 can be unconservative for thick slabs with low reinforcement ratios. The new fib Model Code provisions for punching offer an effective method for determining the full load-rotation behaviour of a slab up to failure, including accurate failure predictions. A summary of the background of current design procedures and standards will be presented, and a comparison between the different design equations and theories will be given. Based on the findings of this project, it is proposed that the provisions accepted by the fib Model Code should be considered for implementation in the CSA and ACI standards.

Page generated in 0.1755 seconds