Avaliação tomográfica dos parâmetros anatômicos relevantes na punção renal percutânea nos decúbitos ventral e dorsalArvellos, André Noronha 26 August 2011 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-07-18T11:25:20Z
No. of bitstreams: 1
andrenoronhaarvellos.pdf: 6808287 bytes, checksum: 93e22153b8dde05493e1fda7161ac573 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-22T15:00:04Z (GMT) No. of bitstreams: 1
andrenoronhaarvellos.pdf: 6808287 bytes, checksum: 93e22153b8dde05493e1fda7161ac573 (MD5) / Made available in DSpace on 2016-07-22T15:00:04Z (GMT). No. of bitstreams: 1
andrenoronhaarvellos.pdf: 6808287 bytes, checksum: 93e22153b8dde05493e1fda7161ac573 (MD5)
Previous issue date: 2011-08-26 / Introdução: Impulsionada pelo crescimento da endourologia, a busca de novas
técnicas para o acesso percutâneo, com intuito de tornar o procedimento ainda
menos invasivo e mais seguro, teve como marco os trabalhos de Valdivia Uría, que
propôs e descreveu primeiramente a técnica de punção do paciente em decúbito
dorsal inclinado, mostrando menor tempo de procedimento e melhora nos
parâmetros cardiorrespiratórios durante sua realização em relação à técnica clássica
em decúbito ventral, com sucesso terapêutico e morbidade semelhantes. Mesmo
após mais de 20 anos da descrição da sua técnica e com a publicação de outras
séries de casos por outros autores, a mesma não teve a difusão esperada.
Pacientes e métodos: Foi realizada análise de exames de tomografia
computadorizada de 71 pacientes através de simulações de nefrostomia percutânea
nos decúbitos dorsal e ventral, correlacionando-se os resultados com variáveis
antropométricas e quantificação da gordura abdominal no seu padrão de distribuição
nos compartimentos visceral e subcutâneo. Resultados: Não houve diferença
estatística entre o número de lesões de órgãos abdominais para os diferentes
decúbitos nas simulações realizadas no plano axial (p=0,5621). Nas simulações
oblíquas, os resultados mostraram significância estatística da diferença do decúbito
no risco de lesão, sendo o resultado desfavorável ao decúbito ventral (p=0,0295). O
órgão mais freqüentemente sob risco foi o cólon, seguido de longe pelo intestino
delgado. A avaliação indireta do risco de lesão através de medidas da distância do
cólon ao rim mostrou maior proximidade destes na posição de decúbito ventral, para
ambos os lados, de forma estatisticamente significativa. Quanto à metodologia de
análise, observou-se maior número de lesões nas simulações realizadas no plano
axial do que nas simulações oblíquas tanto no decúbito ventral (p= 0,0274) como no
dorsal (p= 0,0002). Nas simulações no plano axial, os pacientes que tiveram órgãos
lesados mostraram de forma estatisticamente significativa menores peso, índice de
massa corpórea (IMC) e quantidade de gordura visceral independente do decúbito.
No plano oblíquo, não foi observada associação estatística com tais variáveis.
Conclusão: Houve maior risco de lesão de órgãos abdominais (principalmente o
cólon) no decúbito ventral, tanto através das simulações de punção, quanto através
da análise indireta de risco através das medidas de proximidade do cólon com o rim.
A metodologia com as simulações no plano oblíquo mostrou-se mais adequada, com
resultados mais próximos das grandes séries de casos onde o procedimento foi
realizado. Em relação aos dados antropométricos e padrão de distribuição da
gordura abdominal por tomografia computadorizada (TC), os pacientes que tiveram
órgãos lesados apresentaram de forma estatisticamente significativa menores peso,
IMC e área de gordura visceral nas simulações no plano axial, para a análise
conjunta das metodologias em ambos os decúbitos e para a análise conjunta da
ocorrência independente da metodologia ou do decúbito. Na metodologia de análise
no plano oblíquo, os baixos valores de p para as variáveis peso (0,07) e IMC (0,06)
podem representar uma tendência em relação ao risco de lesão, talvez com
significância estatística limitada pelo tamanho da amostra. / Introduction: The search for less invasive and safer techniques of percutaneous
access in endourology had, as landmark, the studies undergone by Valdivia Uria,
who first proposed and described access through the inclined supine position, with
shortened procedure time and better cardiorespiratory parameters, compared with
the traditional access in the prone position, and also showing similar success and
morbidity rates. Although more than 20 years have elapsed since the first publication
of the technique, and despite publications by other authors, the technique has not
been so widely embraced as expected. Patients and methods: 71 patients
underwent simulated percutaneous nephrostomy through computed tomography
(CT), in both the supine and prone positions. The results were correlated with
anthropometric variables and quantification of abdominal fat distribution in the
visceral and subcutaneous compartments. Results: There was no statistical
difference between the number of abdominal organ injuries in the two different
positions in the axial plane (p=0.5621). In oblique simulations, the difference in the
risk of injury to abdominal organs was statistically significant between the two
positions, with more injuries happening in the prone position (p=0.0295). The colon
was the most frequently injured organ, followed by the small intestine in a distant
second. Indirect injury risk assessment by measurement of the colon-kidney distance
showed statistically significant greater proximity of these organs in the the prone
position, on both sides. Concerning the analysis methodology, there were a greater
number of injuries in the axial plane than in the oblique simulations, both in the prone
position (p=0.0274) and in the supine position (p=0.0002). In the axial plane
simulations, patients who suffered organ injuries had statistically significant lower
weight, Body Mass Index (BMI) and visceral fat amount, regardless of the position.
In the oblique plane, no such statistical association was found. Conclusion: There
was greater risk of injury to abdominal organs (mainly the colon) in the prone
position, both in puncture simulations and in indirect risk assessment of risk through
the measurement of the colon-kidney distance. Simulation in the oblique plane was
the most adequate method, as it provided results that were closer to the ones from
large case series in which the procedure was performed. Concerning the
anthropometric factors and the pattern of CT-assessed abdominal fat distribution,
patients who suffered organ injuries had statistically significant lower weight, BMI and
visceral fat amount, in the axial plane, for analysis of the two methods in both
positions and for analysis of the injuries regardless of method and position. In the
oblique plane analysis methodology the low p values for weight (0.07) and BMI (0.06)
may represent a tendency towards the injury risk, maybe with a limited statistical
significance owing to the sample size.
|
512 |
RADIOLOGIA DO INTESTINO DELGADO DE CÃES ATRAVÉS DA TÉCNICA DE DUPLO-CONTRASTE / SMALL BOWEL DOUBLE-CONTRAST RADIOGRAPHIC STUDY IN DOGSRausch, Stella Falkenberg 17 June 2005 (has links)
The detailed visualization of the small bowel at the radiographic series is restricted by factors as loops overlap and content absence that doesn't allow the contrast with the other structures, disabling many times, an accurate radiographic diagnosis. Despite the usefulness of the conventional contrast series in several diagnoses, significant alterations are needed to instigate modification in the positive contrast medium coat to make it evident. The objective of this study was to adjust an exam technique with intestinal double-contrast, based on techniques used in the human medicine, which resulted satisfactorily in the demonstration of the mucosal surface in the 30 dogs submitted to the exam. The double-contrast in the lumen was achieved by a combination of a positive contrast medium, recovering the mucosal surface, and a negative filling the lumen. Ambiental air and carboximethylcelullose were the negative contrast medium tested and both were radiographicly similar / A visualização detalhada do intestino delgado no exame radiográfico é limitada por fatores como a sobreposição das alças e a ausência de conteúdo, o que não permite o devido contraste com as demais estruturas, impossibilitando muitas vezes, um diagnóstico radiológico preciso. Apesar da utilidade da técnica convencional de exame contrastado em diversos diagnósticos, este necessita de alterações significativas para promover modificação no preenchimento feito pelo meio de contraste radiopaco e evidenciá-las radiograficamente. O objetivo deste trabalho foi adaptar uma técnica de exame com duplo-contraste intestinal, baseada em técnicas radiográficas usadas na medicina humana, a qual resultou satisfatoriamente na demonstração da superfície mucosa nos 30 cães submetidos ao exame. O duplo-contraste no interior das alças intestinais foi obtido pela combinação de um meio de contraste positivo, recobrindo a superfície mucosa, e um meio de contraste negativo, preenchendo o lúmen. Dois meios de contraste negativos foram testados: o ar ambiente e a carboximetilcelulose, os quais, radiologicamente, mostraram-se semelhantes
|
513 |
Avaliação por tomografia computadorizada da cavidade torácica de cães naturalmente acometidos por leishmaniose visceralBonatelli, Shayra Peruch. January 2020 (has links)
Orientador: Maria Jaqueline Mamprim / Resumo: A leishmaniose visceral canina geralmente acomete órgãos do sistema mononuclear fagocitário, entretanto, há evidências de que possa lesionar outros órgãos. Pouco se sabe sobre a patogenia da doença na cavidade torácica. Ainda não há descrições radiológicas das alterações torácicas de cães leishmanióticos. O presente estudo realizou avaliação tomográfica em 35 cadáveres de cães positivos e sintomáticos para a doença. Foi possível confirmar linfadenomegalia esternal e visibilizar os linfonodos mediastinais e traqueobrônquicos. Todos os animais apresentaram opacificações do tipo vidro fosco no parênquima pulmonar. Também se observaram opacificações do tipo linear, nodular e banda parenquimal nos pulmões e, ainda, espessamento e dilatação brônquica. A análise histopatológica foi realizada em 13 pulmões e revelou infiltrado inflamatório em diferentes graus, edema, congestão, espessamento de septo alveolar e brônquios congestos. Tais alterações tomográficas e histopatológicas são semelhantes às descritas em humanos. A tomografia computadorizada se mostra uma ferramenta de grande valia para avaliação da cavidade torácica de cães acometidos pela leishmaniose visceral. O acometimento torácico pela leishmaniose visceral canina deve ser considerado em diagnósticos diferenciais quando se observam opacificações do tipo vidro fosco e lineares e linfadenomegalia em exames tomográficos do tórax de cães em áreas endêmicas. / Abstract: Canine visceral leishmaniasis usually affects organs of the mononuclear phagocytic system, however, there is evidence that it can damage other organs. Little is known about the pathogenesis of the disease in the chest cavity. There are still no radiological descriptions of the thoracic changes in leishmaniotic dogs. In this study computed tomography in 35 cadavers of dogs positive and symptomatic for the disease was performed. It was possible to confirm sternal lymphadenomegaly and to visualize the mediastinal and tracheobronchial lymph nodes. All animals presented ground-glass opacifications in the lung parenchyma. Linear, nodular and parenchymal band opacifications were also observed in the lungs, as well as bronchial thickening and dilation. Histopathological analysis was performed in 13 lungs and revealed inflammatory infiltrate in different degrees, edema, congestion, thickening of the alveolar septum and congested bronchi. Such tomographic and histopathologic changes are similar to those described in humans. Computed tomography is a valuable tool for assessing the chest cavity of dogs affected by visceral leishmaniasis. Thoracic involvement by canine visceral leishmaniasis should be considered as differential diagnoses when ground-glass and linear opacifications and lymphadenomegaly are observed in tomographic examinations of the chest of dogs in endemic areas. / Doutor
|
514 |
Radiologia convencional e tomografia computadorizada na avaliação de cães portadores de discopatia cervical: estudo comparativo / Radiologic and computed tomographic evaluation of dogs with disc disease in cervical spine: a comparative studyBurgese, Luciana Fortunato 04 August 2006 (has links)
Foram avaliados 25 cães portadores de discopatia cervical aos exames radiográficos simples, mielografia e tomografia computadorizada. A dor foi o principal sinal clínico em 64% dos casos. Os animais com raça definida foram os mais acometidos (85%), tendo maior incidência da raça Teckel. A faixa etária mais acometida foi entre 7-9 anos (72%). O exame radiográfico simples indicou aspectos compatíveis com extrusão em 14 observações. A mielografia diagnosticou 15 extrusões, 18 protrusões e 4 hérnias de disco e forneceu informações quanto ao grau de compressão medular e extensão das lesões. A tomografia computadorizada (TC) indicou 16 extrusões, 22 protrusões e 3 hérnias de disco. O espaço de C2-3 foi o mais acometido. A TC permitiu o diagnóstico de extrusões calcificadas, mesmo na presença de pouca quantidade ou ausência de meio de contraste e indicou com precisão o grau de compressão medular, a extensão e principalmente, a localização das lesões. Concluiu-se com este estudo que os três exames se complementam e constituem importantes ferramentas para o planejamento clínico-cirúrgico. / Twenty-five dogs with disc disease in cervical spine were evaluated by radiological and computed tomographic exams. The most common clinical signs were neck pain present in 64% of the dogs. Of the animals 85% were pure breed, amongst them Teckel were most frequent (28%). The most cases occurred in animals between seven and nine years. C2-3 was the preferred site of cervical involvement. Radiographic plain indicated fourteen extrusion. Myelography demonstrated fifteen extrusions, eighteen protrusions and four disc hernias and indicated spinal cord grade compression and lesions extension. Computed tomographic (CT) demonstred sixteen extrusions, twenty-two protrusions and three disc hernias. The CT showed to be more sensitive for soft tissue calcification, and his superior contrast resolution allowed visualization small quantities of contrast material in the subarachnoid space and indicated with precision the site and extension of lesions as well as the degree of spinal cord compression. The three exams are complementary and give valuable information for clinical and chirurgical procedures.
|
515 |
Aspectos morfológicos e biométricos da mão e densitométricos do metacarpo de ovinos da raça Santa Inês /Jimenez, Karla Negrão. January 2009 (has links)
Resumo: Considerando-se a falta de informações sobre a morfologia óssea da mão de ovinos, o presente trabalho teve como objetivo descrever os aspectos anatômicos e biométricos da mão de 14 ovinos, machos castrados, da raça Santa Inês como também investigar os valores densitométricos do metacarpo destes animais de diferentes idades. Para isso dissecou-se 14 mãos do membro torácico desses animais, para realização da descrição morfológica após a aplicação da técnica de maceração. A Densidade Mineral Óssea (DMO) do metacarpo foi determinada por meio da técnica de densitometria em imagens radiográficas, após a obtenção dos raios X dos animais vivos aos 12°, 13°, 14° e 15° meses de idade. Para a obtenção das medidas da DMO foi utilizado um software computacional Pró Plus, Média Cybernetics, versão 4.1. Após as análises morfológicas e biométricas das mãos pode-se verificar a semelhança das estruturas ósseas da mão dos ovinos com os bovinos, levando-se em conta o porte médio desta espécie. Além disso, foi observado que os valores densitométricos permaneceram estáveis no decorrer do período experimental. Diante disto sugere-se uma avaliação densitométrica por um período de tempo maior do que foi utilizado neste estudo / Abstract: Considering few information of bone morphology in sheep hand, this study aimed to describe the anatomy and biometric of the hand of 14 sheep, castrated male, Santa Inês also investigate the densitometric values of metacarpus in animals of different ages. For this 14 hands was dissect of the thoracic limb of these animals to the morphological description after applying the technique of maceration and the bone mineral density (BMD) of the metacarpal was determined using the technique of optical densitometry in radiographic images. To measure BMD it was used computer software Pró Plus, Media Cybernetics, version 4.1. After the morphological and biometric hands analyses was verify the similarity of the bony hand of sheep with cattle, taking into account the medium size of this species. Furthermore, it was observed that the bone mineral density values remained stable during the experimental period, it is suggested valuation for a longer period than realized in this study / Orientador: Silvana Martinez Baraldi Artoni / Coorientador: José Wanderley Cattelan / Banca: Mário Jefferson Quirino Louzada / Banca: Vanessa Sobue Franzo / Mestre
|
516 |
Elaboração de um guia de referência com imagens radiográficas para aplicação em exames extraorais odontológicos / Elaboration of a reference guide with radiograpich images for application in dental extraoral examsMickus, Joice 27 October 2017 (has links)
Os exames radiológicos são importantes recursos no auxílio da elaboração um diagnóstico odontológico preciso. Contudo, só devem ser realizados quando houver uma real indicação clínica, visto que os efeitos das radiações ionizantes no organismo humano são cumulativos. Falhas na execução de procedimentos radiológicos resultam em imagens com qualidade diagnóstica duvidosa, sendo necessária, muitas vezes, a repetição de exames. Desta forma, métodos para minimizar a rejeição imagens radiológicas devem ser observados. A fim de colaborar para a diminuição dos erros de posicionamentos e consequente rejeição de exames de imagem na área da odontologia, este estudo teve por objetivo a criação de um guia de referência para aplicação em exames extraorais odontológicos. Para a elaboração e estruturação deste guia, foi realizado um estudo com o intuito de identificar os motivos de rejeição de radiografias panorâmicas em um serviço de radiologia odontológica digital. O estudo foi retrospectivo e por meio de uma busca no software de aquisição de imagens, foram selecionadas 2306 radiografias panorâmicas digitais, correspondentes a 10% do total de exames realizados entre os anos de 2013 a 2015. A partir da amostra, foram identificados os exames rejeitados e as causas da rejeição. Ainda para colaborar com o desenvolvimento do guia de referência, foi aplicado um questionário aos profissionais técnicos/tecnólogos atuantes no setor de radiologia onde a pesquisa foi realizada. O questionário contou com nove perguntas relacionadas à rotina de trabalho do setor. Com os resultados obtidos na pesquisa foi possível a elaboração do guia de referência com imagens radiográficas para aplicação em exames odontológicos. / The radiological exams are important resources in aid of drafting a dental diagnosis. However, should only be performed when there is a real clinical indication, since the effects of ionizing radiation on the human body are cumulative. Flaws in the implementation of radiological procedures result in doubtful quality diagnostic images, being necessary, many times, the repetition of exams. In this way, methods to minimize radiological images rejection must be observed. In order to contribute to the reduction of errors of positioning and consequent rejection of imaging examinations in the area of dentistry, this study had as its objective the creation of a reference guide for application in dental extraoral examinations. For the preparation and structuring of this guide, a study was conducted with the aim of identifying the reasons for the rejection of panoramic radiographs in a digital dental radiology service. The study was retrospective and by means of a search in the software of image acquisition, were selected 2306 digital panoramic radiographs, corresponding to 10% of the total number of examinations performed between the years of 2013 and 2015. From the sample, were identified the rejected exams and the causes of rejection. To collaborate with the development of the reference guide, a questionnaire was applied at technical professionals working in the radiology sector where the research was conducted. The questionnaire was attended by nine questions related to routine work in the sector. With the results obtained in the study it was possible to do the preparation of the guide of reference with radiographic images for application in dental examinations.
|
517 |
Improvements in Liquid Chromatography coupled to Mass Spectrometry methods for the determination of legislated and emerging marine toxins in the Northwest Mediterranean coastGarcía-Altares Pérez, María 27 April 2015 (has links)
L’objectiu d’aquesta tesi és millorar l’aplicació de mètodes de cromatografia de líquids acoblada a espectrometria de masses (LC-MS) per a l’estudi de toxines lipofíliques i emergents produïdes per microalgues en un ecosistema litoral mediterrani (Delta de l’Ebre, Catalunya, NO Mar Mediterrani). La primera contribució fou l’avaluació de diferents condicions per implementar el mètode de control de referència de toxines lipofíliques en bivalves, obtenint majors rendiments i complint amb els requeriments legals. Aquest mètode s’aplicà en l’estudi d’una floració de Dinophysis sacculus a la badia dels Alfacs, considerant diferents aproximacions per caracteritzar el risc: anàlisi de toxines en microalgues, dissoltes en aigua, i en bivalves. Els perfils toxínics de D. sacculus només presentaren àcid okadaic i pectenotoxina-2 (la toxina principal). El contingut de toxina total per cèl·lula s’incrementà cap al final de la floració, coincidint amb la màxima concentració d’àcid okadaic en musclos (fins a 3,7 vegades el màxim permès a Europa), la concentració de pectenotoxines fou menor. Els ostrons no acumularen toxines per sobre del nivell màxim permès. El mètode LC-MS permeté la detecció de les toxines emergents pinatoxina-g (primera detecció a Espanya) i espiròlid-1, les quals foren confirmades inequívocament mitjançant MS d’alta resolució, en concentracions baixes en marisc i mostrejadors passius. No es detectaren metabòlits acilats de pinatoxines i els falsos positius es descartaren amb informació ortogonal. Les toxines emergents denominades palitoxines també s’investigaren, i es descobriren dues noves palitoxines en cultius de noves soques d’Ostreopsis cf. ovata de Catalunya: l’ovatoxina-g (46-dehidroxi ovatoxina-a) i un isòmer de la palitoxina (anteriorment “palitoxina putativa”), igual que la palitoxina però hidroxilada en C-42 i entre l’extrem A y C-8, i deshidroxilada en C-17 i probablement en C-64. Els perfils toxínics contenien ovatoxines-a,-b,-c,-d i –e, amb concentracions per cèl·lula majors que les d’altres soques mediterrànies. / El objetivo de esta tesis es mejorar la aplicación de métodos de cromatografía de líquidos acoplada a espectrometría de masas (LC-MS) para el estudio de toxinas lipofílicas y emergentes producidas por microalgas en un ecosistema litoral mediterráneo (Delta del Ebro, Cataluña, NO Mar Mediterráneo). La primera contribución fue la evaluación de diferentes condiciones para implementar el método de control de referencia de toxinas lipofílicas en bivalvos, obteniendo mayores rendimientos y cumpliendo con los requerimientos legales. Este método se aplicó al estudio de una floración de Dinophysis sacculus en la bahía de Alfacs, considerando diferentes aproximaciones para caracterizar el riesgo: análisis de toxinas en microalgas, disueltas en agua, y en bivalvos. Los perfiles toxínicos de D. sacculus sólo presentaron ácido okadaico y pectenotoxina-2 (la más abundante). El contenido de toxina total por célula se incrementó hacia el final de la floración, coincidiendo con la máxima concentración de ácido okadaico en mejillones (hasta 3.7 veces el máximo permitido en Europa), la concentración de pectenotoxinas fue menor. Las ostras no acumularon toxinas por encima del nivel permitido. El método LC-MS permitió la detección de pinatoxina-g (primera detección en España) y espirólido-1 (toxinas emergentes), confirmadas inequívocamente mediante MS de alta resolución, en concentraciones bajas en bivalvos y muestreadores pasivos. No se detectaron metabolitos acilados de pinatoxinas, y los falsos positivos se descartaron con información ortogonal. Las toxinas emergentes denominadas palitoxinas también se investigaron, y se descubrieron dos nuevas palitoxinas en cultivos de nuevas cepas de Ostreopsis cf. ovata de Cataluña: ovatoxina-g (46-dehidroxi ovatoxina-a) y un isómero de la paltoxina (anteriormente “palitoxina putativa”), igual que la palytoxina pero hidroxilada en C-42 y entre el extremo A y C-8, y dehidroxilada en C-17 y probablemente en C-64. Los perfiles toxínicos contenían ovatoxinas-a,-b,-c,-d y –e, con concentraciones por célula mayores que las de otras cepas mediterráneas. / This thesis aims to improve the application of liquid chromatography coupled to mass spectrometry (LC-MS) methods for the study of lipophilic and emerging toxins produced by microalgae in a coastal Mediterranean environment (Ebro Delta, Catalonia, Spain, NW Mediterranean Sea). The first contribution was the evaluation of different conditions for the implementation of the official reference control method for lipophilic toxins in shellfish, in order to obtain higher sample throughput and meet legal requirements. This method was applied to study a bloom of Dinophysis sacculus in Alfacs Bay, considering different approaches to characterize risks: analysis of toxins in microalagae, dissolved in water and in shellfish. Toxin profiles of D. sacculus only included okadaic acid and pectenotoxin-2 (the most abundant). Toxin content per cell increased towards the end of the bloom, concomitant with the maximum okadaic acid concentration in mussels (up 3.7 times the maximum permitted level in Europe), pectenotoxins were accumulated at lower concentrations. Oysters did not accumulate toxins over the maximum permitted level. The optimized method allowed the detection of the emerging toxins pinnatoxin-g (first report in Spain) and spirolide-1, which were unequivocally confirmed by High Resolution MS at low concentrations in shellfish and passive samplers. Acyl ester metabolites of pinnatoxins were not detected, and false positives were discarded by orthogonal information. The emerging toxins named palytoxins were also investigated in the study area, and two new palytoxins were discovered in cultures of new strains of Ostreopsis cf. ovata from Catalonia: ovatoxin-g (46-dehydroxy ovatoxin-a) and isomeric palytoxin (formerly “putative palytoxin”), like palytoxin but hydroxylated at C-42 and in the segment from the A-side terminal to C-8, and dehydroxilated at C-17 and most likely at C-64. Toxin profiles also contained ovatoxin-a, -b, -c, -d and –e, at concentrations per cell higher than toxin quotas reported for other Mediterranean strains.
|
518 |
Efeito da ação combinada de radiação gama e campo elétrico estático em células humanas. / Effect of the combined action of gamma radiation and static fields in human cells.Moron, Michelle Mendes 19 August 2008 (has links)
Neste trabalho estudamos o efeito da exposição de células humanas à radiação ionizante e em associação a campos elétricos exógenos estáticos. A linhagem T47D de células de carcinoma ductal mamário foi irradiada com gamas no intervalo 0 8 Gy. A viabilidade celular da linhagem T47D exposta à radiação gama e campo elétrico estático (CEE) de 1.250 V/cm foi cerca de 12% inferior à viabilidade observada apenas com irradiação. Quando aplicado isoladamente por 24 e 72 horas o CEE não induziu toxicidade. A imunofluorescência realizada na linhagem normal MRC5 (fibroblasto de pulmão humano normal) quantificou a expressão da histona -H2AX. A quantidade de histonas fosforiladas foi cerca de 40% maior após irradiação com 2 Gy mais CEE aplicado por 1h, indicando que o campo elétrico interferiu negativamente no processo de reparo das quebras duplas de DNA. A análise de citometria de fluxo (FACS) mostrou que em células T47D tratadas com 1 e 2 Gy por 24 horas o CEE também interferiu negativamente no processo de reparo do DNA, notadamente pelo maior acúmulo de células na fase S. / Our goal is the study in human cells of the effect resulting from the association of irradiation with exposure to exogenous static electric fields. The T47D cell line of breast cancer cells was irradiated with gammas in the 0 8 Gy doses range. The viability of this T47D cells exposed to both gamma radiation and 1.250 V/cm static electric field (SEF) was about 12% lower than when only irradiated. The sole exposure of the cells to SEF by 24 and 72 hours didnt induce toxicity. Immunofluorescence runs carried out in irradiated normal MRC5 cell line of human lung fibroblast have quantified the expression of the g-H2AX histone. The amount of phosphorylated histones was approximately 40% higher after irradiation with 2 Gy plus exposure to a SEF by 1 hour, showing that the electric field negatively interfered in the repairing process of the DNA double strand breaks. The flow cytometry analysis with FACS showed that in T47D cells treated with 1 and 2 Gy by 24 hours the SEF also negatively interfered in the DNA repairing process, as evidenced by the higher accumulation of cells in the S phase.
|
519 |
Avaliação de sistemas de controle automático de exposição em tomografia computadorizada / Evaluation of Automatic Exposure Control Systems in Computed TomographyReina, Thamiris Rosado 15 August 2014 (has links)
O desenvolvimento da tecnologia de tomografia computadorizada (TC) trouxe maiores possibilidades em medicina diagnóstica. É um método não invasivo de se explorar o corpo humano detalhadamente. Com o aumento das aplicações em TC, aumenta a preocupação com as altas taxas de dose administradas quando comparada com outras modalidades de diagnóstico por imagem. A comunidade científica e os fabricantes uniram esforços para alcançar níveis menores de dose possíveis, sem comprometer a qualidade da imagem diagnóstica. O maior e relativamente novo avanço nessa busca para diminuir os níveis de dose é o controle automático de exposição (CAE) em TC. Esses sistemas foram projetados para ponderar a distribuição de dose ao longo do comprimento de varredura e entre pacientes, levando em consideração o tamanho e as diferentes densidades de tecidos irradiados. Baseando-se na geometria de aquisição em TC, os sistemas CAE são altamente complexos. Sendo assim, sua forma de funcionamento ainda não é inteiramente conhecida. O presente trabalho tem como objetivo avaliar o desempenho clínico dos sistemas CAE, suas susceptibilidades ao usuário e, com isso, ajudar na otimização de dose em pacientes. A abordagem utilizada para avaliar os sistemas CAE de três dos maiores fabricantes de TC no Brasil, General Electric, Philips e Toshiba, foi pela extração dos valores de corrente anódica do cabeçalho da sequência de imagens no padrão DICOM, medição e análise do ruído das imagens dessas sequências e a medição da distribuição da dose ao longo do comprimento de varredura nas superfícies e dentro de dois simuladores de paciente de formatos diferentes. A variação da corrente anódica de cada equipamento de TC associada à qualidade da imagem resultante fornece o desempenho do sistema CAE. As medições de distribuição de dose fornecem o perfil de dose resultante da modulação de corrente. Medições com e sem o sistema CAE acionado foram feitas para quantificar a importância em termos de dose desses sistemas. Os resultados obtidos permitem otimizações no uso dos sistemas CAE e, consequentemente, a redução da dose no paciente sem comprometer a qualidade diagnóstica da imagem. / The development of the computed tomography (CT) technology has brought wider possibilities on diagnostic medicine. It is a non-invasive method to see the human body in details. As the CT application increases, it raises the concern about patient dose, because the higher dose levels imparted compared to other diagnostic imaging modalities. The radiology community (radiologists, medical physicists and manufacturer) are working together to find the lowest dose level possible, without compromising the diagnostic image quality. The greatest and relatively new advance to lower the patient dose is the automatic exposure control (AEC) systems in CT. These systems are designed to ponder the dose distribution along the patient scanning and between patients taking into account their sizes and irradiated tissue densities. Based on the CT scanning geometry, the AEC-systems are very complex and their functioning is yet not fully understood. This work aims to evaluate the clinical performance of AEC-systems and their susceptibilities to assist on possible patient dose optimizations. The approach to evaluate the AEC-systems of three of the leading CT manufacturers in Brazil, General Electric, Philips and Toshiba, was the extraction of tube current modulation data from the DICOM standard image sequences, measurement and analysis of the image noise of those image sequences and measurement of the dose distribution along the scan length on the surface and inside of two different phantoms configurations. The tube current modulation of each CT scanner associated to the resulted image quality provides the performance of the AEC-system. The dose distribution measurements provide the dose profile due to the tube current modulation. Dose measurements with the AEC-system ON and OFF were made to quantify the impact of these systems regarding patient dose. The results attained give rise to optimizations on the AEC-systems applications and, by consequence, decreases the patient dose without compromising the diagnostic image quality.
|
520 |
Comparação da eficácia antibacteriana do álcool 70% (p/v) sobre superfície da câmara escura portátil com e sem limpeza prévia: um estudo experimental laboratorial / Comparison of the antibacterial efficacy of the alcohol 70% (w/v) over portable darkroom surfaces through rubbing, with and without previous cleaning processes: a laboratorial and experimental studyGraziano, Maurício Uchikawa 09 August 2011 (has links)
No contexto da prevenção da infecção cruzada na radiologia odontológica, superfícies que entram em contato direto com as mãos dos profissionais, como as superfícies da câmara escura portátil, devem ser descontaminadas. A recomendação clássica da descontaminação com álcool 70% p/v após limpeza prévia, nem sempre é seguida justificada pela não praticidade, acrescida do tempo curto disponível entre um atendimento e outro, limitando-se à aplicação direta do álcool o que, a priori, contraria as Boas Práticas de Controle de Infecção. A presente investigação, de caráter experimental laboratorial, controlado, randomizado e unicegado, teve como objetivo avaliar comparativamente a eficácia desinfetante do álcool 70% (p/v) sob fricção, com e sem limpeza prévia nas superfícies de câmaras escuras portáteis como procedimento de limpeza/desinfecção concorrente em radiologia odontológica. Três grupos de estudo foram constituídos: Grupo controle: superfícies previamente contaminadas com desafio (micro-organismo teste Serratia marcescens ATCC 14756, acrescido de 10% de saliva humana), submetidas à limpeza clássica por meio de água e detergente sob fricção, e posterior enxágue e consecutivamente, desinfecção com aplicação do álcool 70% p/v. Grupo experimental: superfícies previamente contaminadas com desafio, à semelhança do grupo controle, submetidas à aplicação direta do álcool 70% p/v sob fricção, SEM limpeza prévia. Grupo controle positivo: superfícies contaminadas com desafio. O tamanho amostral para os grupos experimental e controle foi de 85 unidades. Os experimentos foram realizados no Laboratório de Ensaios Microbiológicos do Departamento de Enfermagem Médico-Cirúrgica da Escola de Enfermagem da Universidade de São Paulo. Após o procedimento de contaminação, desafio da área superior da câmara escura portátil e sua posterior secagem, no grupo experimental a superfície foi diretamente friccionada com álcool 70% (p/v) durante 30 segundos. No grupo controle, o mesmo procedimento foi realizado, após a limpeza prévia. Imediatamente, após a evaporação do álcool da superfície, foi realizada a coleta microbiológica por meio da fricção com swab. Em seguida, a ponta do swab foi quebrada e mergulhada em um tubo de ensaio esterilizado com 1 mL de SF e agitado em Votex® por 30 segundos, intermitente e todo o conteúdo do tubo de ensaio foi vertido no centro de uma placa de Petri e, sobre ele, derramados 15 a 20 mL do meio Trypticase Soy Agar à temperatura aproximada de 30ºC. As placas foram deixadas na posição invertida, em ambiente à temperatura aproximada de 22ºC por 72 horas, com leitura diária da recuperação das UFC da Serratia marcescens. O controle positivo foi colhido da mesma forma que o dos Grupos Controle e Experimental, porém sem a aplicação de métodos para descontaminação. As médias das UFC foram comparadas entre os grupos experimental e controle, por meio do teste estatístico t de Student. Os resultados permitiram concluir que o álcool 70% p/v, quando aplicado diretamente sobre a superfície contaminada com matéria orgânica sob fricção, é um desinfetante eficaz, comprovado pela redução de seis logaritmos da população microbiana intencionalmente desafiada nos experimentos, não diferindo da redução observada no grupo controle (p=0,440). Estes achados permitiram atestar a segurança desta prática na limpeza/desinfecção concorrente durante as práticas de radiologia odontológica. / Aiming to avoid cross infection in the context of dental radiology, surfaces that get in direct contact with the hands of the professionals involved in dental procedures are ought to be decontaminated, such as the portable darkroom surfaces. The classical recommendation for the alcohol 70% w/v decontamination (which requires previous cleaning process) is not always applied due to its lack of practicality in addition to the short amount of time between dental procedures; so the decontamination is restricted only to the application of alcohol contradicting then, a priori, the good Practices of Infection Control. This investigation, which was conducted following laboratorial and experimental character, controlled, randomized and blinded, has had as its aim: evaluating comparatively the disinfecting efficacy of rubbing the surfaces of portable darkrooms with 70% w/v alcohol, with and without previous cleaning processes, as an alternative procedure for cleaning/disinfection in dental radiology. Three study groups were established: Control Group: previously contaminated surfaces with the worst case contaminant (test microorganism Serratia marcescens ATCC 14756 added to 10% of human saliva) firstly, traditionally cleaned by rubbing with water and detergent, rinsed afterwards then decontaminated using alcohol 70% w/v; Experimental Group: previously contaminated surfaces with the worst case contaminant similarly to Control Groups sample, however submitted straight away to the decontamination by rubbing with alcohol 70% w/v, with NO previous cleaning processes; Positive control Group: surfaces contaminated with the worst case contaminant. The sampling for both, the experimental and control groups, was 85 units. The experiments were conducted at the Microbiology Laboratory of the Medical-Surgical Nursing Department of the University of Sao Paulos Nursing School. After the worst case contamination procedure of the portable darkrooms upper area and drying, at the experimental group: the surface was directly rubbed with alcohol 70% w/v for thirty seconds. At the control group, the same procedure was performed, however, with previous cleaning following the traditional processes. Immediately after the alcohols evaporation from the surface, a microbiological collection was performed by swab friction. Afterwards, the swabs tip was broken and put in a sterile test-tube with 1mL of sterile saline solution and shaken in Vortex® for thirty seconds, and all its content poured into a Petri dish. Fifteen to 20 mL of Trypticase Soy Agar at approximately 30ºC was poured over the Petri dish. The dishes were left inverted, in an acclimatized environment (approximately at 22ºC) for 72 hours, with daily assessment of the Serratia marcescens CFUs (Colony-forming unit) growths. The positive control was collected following the same procedure as the other groups (control and experimental), with no decontamination methods applied. The CFU levels were compared between the Control and Experimental groups, regarding the statistic test of the t test of Student. The results allowed concluding that the alcohol 70% w/v rubbing, when applied straight to the contaminated surface, is an efficient disinfection method, proved by the 6 logs reduction of the worst case bacterial population; no different from the reduction observed at the control group (p=0,440 test t of Student). These results allow attesting and ratifying the safety of this alternative cleaning/disinfection processes in the context of dental radiology.
|