• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 216
  • 60
  • 33
  • 2
  • Tagged with
  • 306
  • 133
  • 86
  • 64
  • 48
  • 40
  • 40
  • 40
  • 37
  • 37
  • 35
  • 33
  • 32
  • 31
  • 30
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Développement d'un dosimètre diamant pour une mesure de la dose absorbée dans les mini-faisceaux utilisés en radiothérapie stéréotaxique. / Development of a diamond dosimeter for measuring the absorbed dose in small beams used in stereotactic radiotherapy

Marsolat, Fanny 10 January 2014 (has links)
La radiothérapie stéréotaxique est une technique de pointe relativement récente utilisée pour le traitement de tumeurs bénignes ou malignes de petites dimensions employant des mini-faisceaux. L'efficacité clinique de cette technique est prouvée et n'est pas remise en cause, cependant il n'existe pas actuellement de dosimètre véritablement approprié permettant de caractériser ces faisceaux de petites dimensions par des mesures précises de dose absolue et relative. Le problème du manque d'équilibre électronique latéral rencontré en mini-faisceaux entraîne principalement les contraintes suivantes pour le dosimètre : équivalence-eau et petit volume de détection. Les caractéristiques du diamant (faible numéro atomique Z=6, densité élevée d'atomes) en font un candidat idéal. Au cours de cette thèse, nous avons développé un prototype de dosimètre pour mini-faisceaux à partir de diamant monocristallin synthétique CVD. Les échantillons ont été caractérisés optiquement par différentes techniques et leurs propriétés de détection ont été étudiées sous rayonnement X et sous particules ?. Une série de premiers prototypes a été développée et testée sur plusieurs machines de stéréotaxie. Une étape d'optimisation de ces premiers dosimètres diamant a ensuite été réalisée notamment par l'utilisation de simulations Monte Carlo. L'optimisation des différents paramètres entrant en jeu dans la réponse du dosimètre en mini-faisceaux a permis d'aboutir à un prototype final de dosimètre diamant. Ce prototype répond au cahier des charges rédigé par les physiciens médicaux des centres hospitaliers, aussi bien en champs standards qu'en mini-faisceaux. / Stereotactic radiotherapy is a relatively recent technique used for the treatment of small benign and malignant tumors with small radiation beams. The clinical efficiency of this technique has been proved. However, the measurement of absolute and relative dose in small beams is not possible currently due to the lack of suited detectors for these measurements. In small beam dosimetry, the detector has to be as close as possible to tissue equivalence and exhibit a small detection volume due to the lack of lateral electronic equilibrium. Characteristics of diamond (water equivalent material Z=6, high density) make it an ideal candidate to fulfil most of small beam dosimetry requirements. In this thesis, we developed a dosimeter prototype for small beams, based on CVD synthetic single crystal diamond. The diamond samples were characterized optically and their detection properties were investigated under X-rays and alpha-particles. First diamond dosimeter prototypes were tested with small beams produced by several stereotactic machines. Studies using Monte Carlo simulations were performed in order to optimize the parameters involved in the detector response in small beams. This leaded to a final diamond dosimeter prototype that respects all radiotherapy centers requirements, in both standard and small beams.
182

Contribution mécanique à la réduction des marges en radiothérapie de la prostate : modélisation et simulation numérique du mouvement et de la déformation des organes pelviens / Mechanical approach for reducing margins during prostate radiotherapy : modeling and finite element simulation of the motion and deformation of pelvic organs

Boubaker, Mohamed Bader 03 December 2009 (has links)
La prostate est un organe pelvien qui joue un rôle important dans son environnement anatomique, notamment en assurant la sécrétion d’un liquide essentiel dans la composition du liquide séminal. Le cancer de la prostate représente la première cause mortalité chez l’homme à un âge avancé. Ce travail concerne le développement par la méthode des éléments finis d'un modèle numérique du mouvement des organes pelviens (prostate, vessie, rectum) et de leurs interactions. L’objectif est la réduction des marges d'irradiation du volume cible au cours d'une séance de radiothérapie, afin de ne pas altérer les organes sains avoisinants. Les marges choisies sont importantes compte tenu du fait que la prostate subi des déplacements importants lors des interactions permanentes avec les organes avoisinants. Un premier modèle est construit à partir de la géométrie des organes pelviens générée à partir d'images scanner acquises sur patients. Des lois hyper-élastiques sont adoptées pour modéliser le comportement mécanique du rectum et de la vessie et un comportement Hookéen est considéré pour la prostate. Les paramètres physiques du modèle sont déterminés à partir de la littérature, des données expérimentales et de nos propres mesures. Les conditions aux limites cinématiques et statiques (pressions de distension intra-vésicale et intra-rectale) sont définies à partir des observations anatomiques et reflètent la présence de l’entourage anatomique et les conditions de chargement. Des comparaisons entre les variations de forme et de position d'organes obtenues par simulation et les mesures obtenues par imagerie scanner (Keros et al. ; 2006) montrent des amplitudes de déplacements proches, avec des écarts variant entre 8% et 11%. Un modèle prenant en compte la variabilité des paramètres physiques inter et intra patients est envisagé en perspectives / The prostate plays an important biological role in the human body, such as secretion of some prostatic liquid essential in the semen composition. Prostate cancer is the first cause of mortality for men at an advanced age. The prostate motion due to the interactions with the surrounding anatomic entities is difficult to predict, hence important margins are usually adopted during X-ray irradiation, in order not to damage the surrounding healthy organs (bladder and rectum). The principal objective of this work is to set up a FE model of the motion and deformation of the human pelvic organs in order to reduce the margins. A first model is constructed from CT-scans of the human pelvic organs, allowing the generation of the organ geometrics. Hyperelastic modeling of the bladder and rectum behaviors were considered whereas a Hookean model was retained for the prostate. The model parameters are fixed by adopting literature data, experimental data (from CHU-Nancy) and experimental measurements achieved on pig. Boundary conditions are defined according either surrounding anatomy kinematic constraints or internal pressures that correspond to the bladder and rectum repletion’s. Simulated displacements show order of magnitudes of the prostate motion very close to measurements carried out by Keros et al. (2006) on a deceased person, with a relative error ranging from 8% to 11%. Those differences are essentially due to the variability in the physical parameters, pointing out the need for a statistical approach in order to take into account the material, geometrical and loading variability related to a panel of patients
183

Approche basées sur l'apprentissage en profondeur pour la segmentation des organes à risques dans les tomodensitométries thoraciques. / Deep learning based approaches for the segmentation of Organs at Risk in Thoracic Computed Tomography Scans

Trullo Ramirez, Roger 12 November 2018 (has links)
La radiothérapie est un traitement de choix pour le cancer thoracique, l’une des principales causes de décès dans le monde. La planification de la radiothérapie nécessite de contourer non seulement la tumeur, mais également les organes à risque (OAR) situés près de la tumeur dans le thorax, tels que le coeur, les poumons, l’oesophage, etc. Cette segmentation permet de minimiser la quantité d’irradiation reçue pendant le traitement. Aujourd’hui, la segmentation de OAR est réalisée principalement manuellement par des cliniciens sur des images scanner (CT), malgré une prise en charge logicielle partielle. C’est une tâche complexe, sujette à la variabilité intra et interobservateur. Dans ce travail, nous présentons plusieurs méthodologies utilisant des techniques d’apprentissage profond pour segmenter automatiquement le coeur, la trachée, l’aorte et l’oesophage. En particulier, l’oesophage est particulièrement difficile à segmenter, en raison de l’absence de contraste et de variabilité de forme entre différents patients. Les réseaux profonds convolutionnels offrent aujourd’hui des performances de pointe en matière desegmentation sémantique, nous montrons d’abord comment un type spécifique d’architecture basée sur des skip connections peut améliorer la précision des résultats, par rapport à un réseau pleinement convolutionnel (FCN) standard. Dans une deuxième contribution, nous avons intégré des informations de contexte spatial au processus de segmentation, par le biais de réseaux collaboratifs, permettant les segmentations de chaque organe individuellement. Troisièmement, nous proposons une représentation différente des données, basée sur une carte de distance, utilisée en conjointement avec des réseaux adversariaux (GAN), comme un autre moyen de contraindre le contexte anatomique. Les méthodes proposées ont été évaluées sur une base d’images scanner de 60 patients. Les résultats montrent des résultats encourageants pour l’application clinique et souligne le potentiel des méthodes prenant en compte le contexte spatial dans la segmentation. / Radiotherapy is one of the options for treatment currently available for patients affected by cancer, one of the leading cause of deaths worldwide. Before radiotherapy, organs at risk (OAR) located near the target tumor, such as the heart, the lungs, the esophagus, etc. in thoracic cancer, must be outlined, in order to minimize the quantity of irradiation that they receive during treatment. Today, segmentation of the OAR is performed mainly manually by clinicians on Computed Tomography (CT) images, despite some partial software support. It is a tedious task, prone to intra and inter-observer variability. In this work, we present several frameworks using deep learning techniques to automatically segment the heart, trachea, aorta and esophagus. In particular, the esophagus is notably challenging to segment, due to the lack of surrounding contrast and shape variability across different patients. As deep networks and in particular fully convolutional networks offer now state of the art performance for semantic segmentation, we first show how a specific type of architecture based on skip connections can improve the accuracy of the results. As a second contribution, we demonstrate that context information can be of vital importance in the segmentation task, where we propose the use of two collaborative networks. Third, we propose a different, distance aware representation of the data, which is then used in junction with adversarial networks, as another way to constrain the anatomical context. All the proposed methods have been tested on 60 patients with 3D-CT scans, showing good performance compared with other methods.
184

Evaluation préclinique d’une nouvelle stratégie de radiosensibilisation pharmacologique : l’inhibition des histones désacétylases / Preclinical Evaluation of a Novel Strategy of Pharmacological Radiosensitization : the Inhibition of Histone Deacetylases

Rivera, Sofia 12 December 2016 (has links)
Les résultats insuffisants de la radiochimiothérapie conventionnelle dans les cancers bronchiques non à petites cellules (CBNPC) ont motivé l’évaluation d’une nouvelle stratégie de modulation pharmacologique de la radiosensibilité tumorale basée sur les modifications épigénétiques. Pour cela nous avons évalué la combinaison de la radiothérapie et d’un nouvel pan-inhibiteur des histones déacétylases (HDACi), l’abexinostat en préclinique in vitro et in vivo sur deux modèles de CBNPC puis en phase clinique précoce chez l’homme dans le cadre d’un essai de phase I. Nous avons d’abord montré que l’abexinostat augmente la radiosensibilité des cellules de CBNPC de manière dépendante de la séquence thérapeutique en normoxie et en hypoxie en augmentant l’apoptose caspase dépendante ainsi que les cassures doubles brins radio-induites et en réduisant la signalisation et la réparation de ces dommages de l’ADN. L’abexinostat potentialise également le retard de croissance tumorale induit par la radiothérapie in vivo dans des xénogreffes sous-cutanées de CBNPC avec un profil de toxicité acceptable. Nous avons également montré pour la première fois que la triple combinaison de radiothérapie, abexinostat et cisplatine potentialise le retard de croissance tumorale in vivo.Les premiers résultats in vitro et in vivo confortant le rationnel pour la combinaison abexinostat-radiothérapie nous avons réalisé étude de phase I exploratoire d’escalade de dose combinant l’abexinostat à la radiothérapie palliative hypofractionnée standard délivrant 30y en 10 fractions pour des tumeurs solides métastatiques. Parmi les 58 patients traités, d’âge médian 61 ans (20-82), on note 71% de stade M1 et 88% de patients ayant déjà reçu des traitements préalables par chimiothérapie et/ou radiothérapie et/ou chirurgie. La dose recommandée pour un essai de phase 2 que nous avons établie est de 90mg/m². Sur les 51 patients évaluables, on observe un taux de réponse globale de 7,8% (1 réponse complète (RC) et 3 réponses partielles (RP)) et un taux de réponse locorégionale de 11,8% (1 RC et 5 RP) avec un suivi médian de 16 semaines. Les patients présentant des lésions (cibles ou non) cérébrales ont présenté des taux de réponse encourageant avec notamment un patient en RC. Nous avons retrouvé peu d’effets secondaires de grade ≥3, les plus fréquents étant la thrombopénie (17,2%), la lymphopénie (12,1%) et l’hypokaliémie (6,9%). Au total, 6 patients (10%) ont interrompu leur traitement du fait des effets secondaires. Nous n’avons pas observé de prolongation de l’intervalle QTc de grade ≥3 et il n’y a pas eu d’interruption de traitement en rapport avec cet effet secondaire. Dans l’ensemble nos données in vitro et in vivo montrent une potentialisation de l’effet antitumoral par la combinaison d’abexinostat et radiothérapie. Chez les patients présentant des tumeurs solides avancées l’abexinostat oral en combinaison à la radiothérapie est bien toléré. Cette combinaison pourrait avoir un potentiel particulièrement intéressant dans le traitement des métastases cérébrales.De plus nos travaux précliniques suggèrent pour la première fois un effet prometteur d’une triple combinaison avec HDACi, cisplatine et radiothérapie qui justifie de plus amples investigations et pourrait guider de nouvelles stratégies thérapeutiques dans les CBNPC.Nos travaux s’inscrivent dans une stratégie de recherche translationnelle et montrent l’importance de la recherche préclinique pour les études d’association aux rayonnements ionisants. Seuls un développement préclinique rationnel et un développement clinique méthodique permettront l’émergence de combinaisons modulant la radiosensibilité tumorale de manière suffisamment efficace pour modifier nos standards de traitement et améliorer le pronostic de nos patients. / Insufficient results of conventional chemoradiotherapy in non-small cell lung carcinomas (NSCLC) have encouraged assessment of new pharmacological strategies for modulation of radiosensitization based on epigenetic changes. We have investigated the combination of radiotherapy and a novel pan-histone deacetylase inhibitor (HDACi), abexinostat in vitro and in vivo in two NSCLC models and in an early phase clinical trial. Our findings demonstrate that abexinostat enhances radiosensitivity of NSCLC cells in a time dependent way in vitro in normoxia and hypoxia increasing radio-induced caspase dependent apoptosis and persistent DNA double strand breaks associated with decreased DNA damage signaling and repair. Interestingly, abexinostat potentiates tumor growth delay in vivo in combined modality treatments associating not only abexinostat and irradiation but also in the triplet combination of abexinostat, irradiation and cisplatin.We conducted an exploratory phase 1, dose-escalation study of abexinostat in combination with standard hypofractionated radiotherapy (30Gy in 10 fractions) in patients with advanced solid tumors treated in a palliative setting. Among 58 treated patients, the median age was 61.5 years (range, 20-82); 47% of the patients had M1 stage disease, and 95% had received previous chemotherapy alone or chemotherapy in combination with surgery and/or radiotherapy. The recommended phase 2 dose was determined to be 90 mg/m2. Of the 51 patients evaluable for response, best overall response was 8% (1 complete response [CR], 3 partial responses [PRs]), and best loco-regional response was 12% (1 CR and 5 PRs) at a median follow-up of 16 weeks. Of note, patients with target or non-target brain lesions showed encouraging responses, with 1 patient achieving a best loco-regional response of CR. Treatment-emergent grade ≥3 adverse events (AEs) were few, with most common being thrombocytopenia (17%), lymphopenia (12%), and hypokalemia (7%). Six patients (10%) discontinued treatment due to AEs. No grade ≥3 prolongation of the QTc interval was observed, with no treatment discontinuations due to this AE.Altogether, our data demonstrate in vitro and in vivo a potentiation of anti-tumor effect by abexinostat in combination with irradiation in NSCLC. Oral abexinostat combined with radiotherapy was well tolerated in patients with advanced solid tumors. The combination may have potential for treatment of patients with brain lesions.Moreover, our work suggest for the first time to our knowledge promising triple combination opportunities with HDACi, irradiation and cisplatin which deserves further investigations and could be of major interest in the treatment of NSCLC.Our studies which are part of a translational research strategy highlight the importance of preclinical investigations in the area of radiotherapy and drug combination research. Only rationale preclinical development and methodologically well conducted clinical development will allow new standards of treatment to emerge and improve patient’s prognostic.
185

Spatial fractionation of the dose in charged particle therapy / Fractionnement spatial de la dose en radiothérapie par particules chargées

Peucelle, Cécile 04 November 2016 (has links)
Malgré de récentes avancées, les traitements par radiothérapie (RT) demeurent insatisfaisants : la tolérance des tissus sains aux rayonnements limite la délivrance de fortes doses (potentiellement curatives) à la tumeur. Pour remédier à ce problème, de nouvelles approches basées sur des modes de dépôt de dose innovants sont aujourd’hui à l’étude. Parmi ces approches, la technique synchrotron “Minibeam Radiation Therapy” (MBRT) a démontré sa capacité à élever la résistance des tissus sains aux rayonnements, ainsi qu’à induire un important retard de croissance tumorale. La MBRT combine des faisceaux submillimétriques à un fractionnement spatial de la dose. Dans ce contexte, l’alliance de la balistique plus avantageuse des particules chargées (et leur sélectivité biologique) à la préservation des tissus sains observée en MBRT permettrait de préserver d’avantage les tissus sains. Cette stratégie innovante a été explorée durant ce travail de thèse. Deux voies ont notamment été étudiées: la MBRT par faisceaux de protons (pMBRT), et d’ions très lourds. Premièrement, la preuve de concept expérimentale de la pMBRT a été réalisée dans un centre clinique (Institut Curie, Centre de Protonthérapie d’Orsay). De plus, l'évaluation de potentielles optimisations de la pMBRT, à la fois en terme de configuration d’irradiation et de génération des minifaisceaux, a été menée dans une étude Monte Carlo (MC). Dans la seconde partie de ce travail, un nouvel usage potentiel des ions très lourds (néon et plus lourds) en radiothérapie a été évalué dans une étude MC. Les combiner à un fractionnement spatial permettrait de tirer profit de leur efficacité dans le traitement de tumeurs radiorésistantes (hypoxiques), un des principaux défis de la RT, tout en minimisant leurs effets secondaires. Les résultats obtenus au terme de ce travail sont favorables à une exploration approfondie de ces deux approches innovantes. Les données dosimétriques compilées dans ce manuscrit serviront à guider prochaines les expérimentations biologiques. / Despite recent breakthroughs, radiotherapy (RT) treatments remain unsatisfactory : the tolerance of normal tissues to radiations still limits the possibility of delivering high (potentially curative) doses in the tumour. To overcome these difficulties, new RT approaches using distinct dose delivery methods are being explored. Among them, the synchrotron minibeam radiation therapy (MBRT) technique has been shown to lead to a remarkable normal tissue resistance to very high doses, and a significant tumour growth delay. MBRT allies sub-millimetric beams to a spatial fractionation of the dose. The combination of the more selective energy deposition of charged particles (and their biological selectivity) to the well-established normal tissue sparing of MBRT could lead to a further gain in normal tissue sparing. This innovative strategy was explored in this Ph.D. thesis. In particular, two new avenues were studied: proton MBRT (pMBRT) and very heavy ion MBRT. First, the experimental proof of concept of pMBRT was performed at a clinical facility (Institut Curie, Orsay, France). In addition, pMBRT setup and minibeam generation were optimised by means of Monte Carlo (MC) simulations. In the second part of this work, a potential renewed use of very heavy ions (neon and heavier) for therapy was evaluated in a MC study. Combining such ions to a spatial fractionation could allow profiting from their high efficiency in the treatment of hypoxic radioresistant tumours, one of the main challenges in RT, while reducing at maximum their side effects. The promising results obtained in this thesis support further explorations of these two novel avenues. The dosimetry knowledge acquired will serve to guide the biological experiments.
186

Caractérisation et manipulation des destins cellulaires induits par les traitements du cancer de la prostate

Vancayseele, Arthur 05 1900 (has links)
La sénescence cellulaire est un mécanisme naturel de suppression tumorale défini par un arrêt stable de la prolifération. Bien que presque toujours mutées dans au moins une des voies déclenchant la sénescence (ex : p53/p21 ou p16/Rb), les cellules cancéreuses conservent souvent la capacité d’y entrer en réponse au traitement. Cette sénescence induite par la thérapie (SIT) peut être ciblée pharmacologiquement pour en renforcer les effets positifs. Une approche émergente consiste à combiner un traitement anticancéreux induisant la sénescence à un sénolytique, agent éliminant spécifiquement les cellules sénescentes. Dans le contexte du cancer de la prostate (CP), différents types de SIT ont déjà été observées dans de multiples modèles exposés à différents traitements. Cependant, le manque de données comparant ces phénotypes souligne le besoin d’analyses plus systématiques. De plus, la sensibilité aux sénolytiques des cellules du CP en état de SIT n’a pas encore été évaluée dans ces contextes. Dans cette étude, nous avons évalué les destins cellulaires des lignées du CP après exposition à trois traitements pertinents au niveau clinique : l’irradiation et l’olaparib, deux inducteurs de dommages à l’ADN et l’enzalutamide, un anti-androgène. Dépendamment de la lignée, les traitements par irradiation et olaparib ont mené à une réponse dirigée principalement vers la sénescence ou vers une réponse mixte de mort cellulaire, de catastrophe mitotique et de sénescence. Dans tous les cas, ceux-ci ont déclenché un phénotype sénescent classique et convertible en mort cellulaire par des sénolytiques inhibiteurs des antiapoptotiques de la famille Bcl-2. D’autre part, le traitement à l’enzalutamide a déclenché un phénotype semblable à la sénescence se distinguant par sa réversibilité, son absence de dommages à l’ADN et son insensibilité à ces mêmes sénolytiques. Globalement, nos résultats soulignent l’importance du contexte thérapeutique dans l’élaboration des stratégies de manipulation de la SIT du CP. Ils constituent également une justification robuste à l’étude préclinique des traitements combinant la radiothérapie ou l’olaparib à des inhibiteurs des antiapoptotiques de la famille Bcl-2 dans le contexte du CP. / Cellular senescence is a natural tumor suppression mechanism defined by a stable proliferation arrest. Although almost always mutated in at least one of the senescence pathways genes (e.g., p53/p21 or p16/Rb), cancer cells often retain the ability to become senescent in response to treatment. This therapy-induced senescence (TIS) can be pharmacologically targeted to enhance its positive effects. An emerging approach is to combine senescence-inducing cancer treatment with senolytics, compounds that specifically eliminate senescent cells. In the context of prostate cancer (PCa), different types of TIS have already been observed in multiple models exposed to different treatments. However, the lack of data comparing these phenotypes highlights the need for more systematic analyses. In addition, the senolytic sensitivity of TIS PCa cells has not yet been evaluated in these settings. In this study, we evaluated the cell fates of PCa cell lines after exposure to three clinically relevant treatments: irradiation and olaparib, two DNA damage inducers, and enzalutamide, an anti-androgen. Depending on the cell line, irradiation and olaparib treatments led to a response mainly directed towards senescence or toward a mixed response of cell death, mitotic catastrophe and senescence. In all cases, these treatments triggered a classic senescent phenotype that was convertible to cell death by senolytic inhibitors of the Bcl-2 family antiapoptotics. On the other hand, treatment with enzalutamide triggered a senescence-like phenotype, distinguishable by its reversibility, absence of DNA damage and insensitivity to these same senolytics. Overall, our results underscore the importance of the therapeutic context in the development of PCa-TIS manipulation strategies. They also provide a robust rationale for the preclinical study of treatments that combine radiotherapy or olaparib with Bcl-2 family antiapoptotic inhibitors in the PCa context.
187

Segmentation du rein fonctionnel à partir de CTdouble énergie injectés

Besnier, Magali 11 1900 (has links)
Les néphropaties (maladie des tissus rénaux) postradiques constituent l'un des facteurs limitants pour l'élaboration des plans de traitement lors des radiothérapies abdominales. Le processus actuel, qui consiste à évaluer la fonctionnalité relative des reins grâce à une scintigraphie gamma deux dimensions, ne permet pas d'identifier les portions fonctionnelles qui pourraient être évitées lors de l' élaboration des plans de traitement. Une méthode permettant de cartographier la fonctionnalité rénale en trois dimensions et d'extraire un contour fonctionnel utilisable lors de la planification a été développée à partir de CT double énergie injectés à l'iode. La concentration en produit de contraste est considérée reliée à la fonctionnalité rénale. La technique utilisée repose sur la décomposition à trois matériaux permettant de reconstruire des images en concentration d'iode. Un algorithme de segmentation semi-automatisé basé sur la déformation hiérarchique et anamorphique de surfaces permet ensuite d'extraire le contour fonctionnel des reins. Les premiers résultats obtenus avec des images patient démontrent qu'une utilisation en clinique est envisageable et pourra être bénéfique. / Post-radic nephroaties (illness of kidney tissues) are one of the limitating factors when realising treatment planning for abdominal radiotherapies. The present process which consists in evaluating the Differential Kidney Function with a two-dimensional gamma scintigraphy, does not allow any identification of functional parts that could be taken into account during planification. The method presented in this document gives a three dimensional functional map of the kidney and a functional contour usable in planification, using double energy CT images with iodine contrast agent.The concentration in contrast agent is assumed to be related to kidney function. The proposed method is based on a three-materials decomposition allowing to reconstruct images of iodine concentration. The functionnal contour is extracted through a semi-automatic algorithm based on hierarchic and anamorphic surface deformation. First results obtained with patient images demonstrate the possibility of several future clinical applications.
188

Modèles d’identification de tissu basés sur des images acquises avec un tomodensitomètre à double énergie pour des photons à faible énergie en curiethérapie

Gaudreault, Mathieu 20 April 2018 (has links)
Les images acquises avec un tomodensitomètre à double énergie (DECT) fournissent la détermination du numéro atomique effectif et de la densité électronique. L'objectif de ce mémoire est de développer un modèle d'identifiation de tissu applicable en curiethérapie, le modèle de tissu réduit à trois éléments, basé sur ces quantités et de le comparer avec une méthode existante dans la littérature, le calcul de la distance de Mahalanobis. Les deux modèles sont appliqués à des images DECT du fantôme de calibration Gammex RMI 467 et pour un sous-ensemble de tissus. Les distributions de dose sont calculées avec des simulations numériques Monte Carlo avec une source point ayant le spectre d'énergie de l'iode 125. Le modèle de tissu réduit à trois éléments reproduit les distributions de dose de référence et peut être utilisé comme étant une méthode d'identifiation de tissu valide pour effectuer un calcul de dose à partir d'images DECT. / Clinical Dual-Energy Computed Tomography (DECT) images provide the determination of the effective atomic number and the electronic density. The purpose of this study is to develop a new assessment model of tissues, named the reduced three elements tissue model, for dose calculations from DECT images in brachytherapy and compare it to a known identification method, assignment through the Mahalanobis distance. Both models are applied to DECT scans of the Gammex RMI 467 phantom and for a subset of 10 human tissues. Dose distributions are calculated from Monte Carlo simulations with a point source having the energy spectrum of 125I. The reduced three elements tissue model provides dose equivalence to reference tissues and is equivalent to the calculation of the Mahalanobis distance. The model constructed can be used as a scheme to assess tissues from DECT images for dose calculation.
189

Facteurs psychologiques associés au cancer de la prostate : comparaison entre les patients traités par radiothérapie, curiethérapie et chirurgie

Hervouet, Séverine 08 April 2021 (has links)
Jusqu'à ce jour, très peu de travaux empiriques ont évalué les aspects psychologiques associés au cancer de la prostate. Cette étude transversale vise donc à comparer la prévalence des difficultés psychologiques (i.e., anxiété et dépression), psychophysiologiques (i.e., insomnie, fatigue) et des difficultés sexuelles en fonction de trois modalités de traitement pour le cancer de la prostate (radiothérapie, curiethérapie et prostatectomie radicale) et du temps écoulé depuis le diagnostic. L'échantillon est composé de 861 hommes ayant complété une batterie de questionnaires. Les résultats démontrent que les difficultés sexuelles constituent le problème le plus fréquent suivies de l'insomnie et de l'anxiété. De plus, les symptômes psychologiques et psychophysiologiques restent relativement stables dans le temps alors que les symptômes physiques tendent à se résorber. Enfin, les patients ayant reçu de la radiothérapie ont un risque plus élevé de souffrir d'humeur dépressive, de détresse psychologique globale et de fatigue comparativement aux patients n'ayant pas reçu ce traitement.
190

Élaboration des éléments d'une simulation Monte Carlo permettant l'évaluation d'une planification de traitement en radiothérapie externe : compression d'images DICOM à l'aide d'un octree et modélisation de la tête d'un accélérateur linéaire

Hubert-Tremblay, Vincent 11 April 2018 (has links)
L'objectif de ce travail est de développer deux modules pour créer une simulation Monte Carlo ayant comme objectif futur de calculer les doses de radiation d'un traitement en radiothérapie externe. Le premier module permet de lire, modéliser et réduire le nombre de voxels présent dans une série d'images médicales de type DICOM. La réduction doit se faire tout en gardant les informations essentielles pour une simulation Monte Carlo. Un algorithme a été développé pour appliquer une compression de type octree à la distribution des densités électroniques recueillies dans les images de tomodensitométrie. L'image résultante possède ainsi une certaine anisotropie au niveau de la résolution. Des résultats obtenus, la réduction du nombre total de voxels atteinte est de l'ordre de 75% de la taille initiale. Les simulations Monte Carlo démontrent qu'aucune information dosimétrique n'est perdue après la transformation. L'efficacité de la simulation se trouve améliorée tant au niveau de sa rapidité que de son utilisation de la mémoire. Le second module développé est un modèle d'accélérateur linéaire de type Primus (Siemens). Ce modèle permet d'obtenir des distributions de doses pour deux faisceaux de photons d'énergies différentes (6 et 23 megavolts [MV]). Dans les deux cas, les distributions de doses ont été comparées à des mesures expérimentales prises avec une chambre à ionisation. Les distributions de doses dans l'axe central du faisceau ont atteint un niveau de précision de 2%. Au niveau des distributions de doses hors axe, les déviations maximales sont de l'ordre de 5% et de 2mm dans les pénombres. Pour le faisceau de 23 MV, la géométrie présente une asymétrie qui devra être corrigée en modifiant le filtre égalisateur ou en utilisant une source de radiation asymétrique. Dans tous les cas, l'ouverture des collimateurs secondaires devra être optimisée afin d'éliminer les erreurs au niveau de la pénombre. Une fois ces modifications effectuées, les images DICOM compressées avec l'octree pourront être insérées à l'intérieur du modèle de l'accélérateur. Ce faisant, il suffirait d'ajuster la configuration des faisceaux et du patient pour évaluer un traitement en radiothérapie externe.

Page generated in 0.0462 seconds