• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 239
  • 2
  • 2
  • Tagged with
  • 247
  • 166
  • 164
  • 114
  • 57
  • 44
  • 35
  • 35
  • 31
  • 29
  • 27
  • 26
  • 24
  • 23
  • 21
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

PÓS-TRATAMENTO DE EFLUENTE DE REATOR ANAERÓBIO UTILIZANDO DUPLA FILTRAÇÃO PARA FINS DE REÚSO

Cavallini, Grasiele Soares 23 October 2015 (has links)
Made available in DSpace on 2017-07-20T12:40:16Z (GMT). No. of bitstreams: 1 Grasiele Cavallini tese.pdf: 2849739 bytes, checksum: 3a66c1a0f56779dc9b4b25e36a7e4b63 (MD5) Previous issue date: 2015-10-23 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / This study evaluates the use of a pilot filtering double unit, comprising an ascending draining gravel filter and a rapid descending sand filter for the treatment of UASB reactor effluent. As a preliminary phase to the double filtering, coagulation/oxidation was used aiming at helping degradation and flocculation of contaminants, facilitating their retention on the filters. In this phase, three combinations were used: ferrous sulfate (FS) and peracetic acid (APA); ferrous chloride (FC) and CF and APA, all with the same iron concentration. After treatability tests, the efficacy of the system was assessed through the physical-chemical and microbiological parameters. In all treatments carried out in the pilot unit, the suspended solids (SST) were totally removed, which resulted in over 90% turbidity reduction. The treatments in the presence of APA demonstrated higher removal of the effluent color, however, the treatment with FS and APA cannot be recommended due to the high concentration of sulfate ions in the final effluent. Regarding microbiological parameters, the presence of oxidant contributed to the partial inactivation of microorganisms. The alternative to carry out a disinfection phase with APA after double filtering using the coagulant/oxidant FC/APA can be employed without any addition phase to irrigate orchards, pastures and cereal crops according to the NBR 13969/97. By adding the pH adjustment phase and chloride addition to the treatment proposed, the treated effluent can be reused in: agriculture, restrictive agriculture; damming, restrictive damming, environment, industry and the replenishment of underground water (except for drinking purposes), according to the recommendations of the USEPA (2012) Recommendation Manual. / Este trabalho avalia o uso de uma unidade piloto de dupla filtração, composta por filtro de pedregulho de escoamento ascendente e filtro rápido descendente de areia para pós-tratamento de efluente de reator UASB. Como etapa preliminar à dupla filtração utilizou-se a coagulação/oxidação, com o objetivo de auxiliar na degradação e na floculação dos contaminantes, facilitando sua retenção nos filtros. Nesta etapa foram utilizadas três combinações: Sulfato ferroso (SF) e ácido peracético (APA); Cloreto férrico (CF) e CF e APA, todas com a mesma concentração de ferro. Após os ensaios de tratabilidade a eficiência do sistema foi avaliada através de parâmetros físico-químicos e microbiológicos. Em todos os tratamentos realizados na unidade piloto os sólidos em suspensão (SST) foram totalmente removidos o que refletiu em reduções superiores a 90% de turbidez. Os tratamentos com a presença do oxidante APA demonstraram uma remoção maior da cor do efluente, porém o tratamento com SF e APA não pode ser recomendado pela alta concentração de íons sulfato no efluente final. Quanto aos parâmetros microbiológicos, a presença do oxidante contribuiu para a inativação parcial dos microrganismos. A alternativa de realizar a etapa de desinfecção com APA após a dupla filtração com CF também foi avaliada e possibilitou desinfecção total do efluente quanto aos indicadores de contaminação avaliados. Considerando a possibilidade de reúso, o efluente UASB pós-tratado pela dupla filtração utilizando o coagulante/oxidante CF/APA pode ser utilizado sem nenhuma etapa adicional para irrigação de pomares, pastagens e cultivo de cereais de acordo com a NBR 13969/97. Acrescentando a etapa de ajuste de pH e adição de cloro no tratamento proposto o efluente tratado pode ser utilizado para reúsos: agrícola; agrícola restritivo; represamento; represamento restritivo; ambiental; industrial e reabastecimento de águas subterrâneas (reutilização não potável), de acordo com as recomendações do manual de reúso da USEPA (2012).
202

Gestão ambiental nos terminais de armazenagem de produtos químicos líquidos a granel no Porto de Santos / Environmental management of storage terminals of liquid chemicals in bulk at Santos Port

Rodrigues, Eleni Stark 12 August 2010 (has links)
O controle das águas residuárias nas indústrias e nos terminais de armazenagem de produtos químicos líquidos a granel é uma difícil tarefa, por conta da alta rotatividade e grande variedade de produtos químicos orgânicos armazenados e movimentados em suas atividades. Oito terminais e duas indústrias químicas localizadas no Porto de Santos foram avaliados por 10 anos. Foram realizadas mais de 2.500 análises químicas e ecotoxicológicas em 200 amostras de efluentes brutos e tratados. Nosso principal objetivo foi verificar se o teste de toxicidade aguda usando Vibrio fischeri poderia ser utilizado na gestão de águas residuais nas diferentes instalações dos terminais químicos e mostrar o seu papel como instrumento de prevenção a poluição, reduzindo a descarga de substâncias tóxicas persistentes nos ambientes aquáticos. Os índices de biodegradabilidade obtidos pela relação de Demanda Bioquímica de Oxigênio (DBO5) / Demanda Química de Oxigênio (DQO) dos efluentes brutos indicaram que 44% das amostras apresentaram matéria orgânica recalcitrante. Das 86 amostras do efluente final analisadas, 45 (52%) apresentaram resultados tóxicos para o teste com V. fischeri. Não houve correlação de DQO e ecotoxicidade, mostrando que efluentes com DQO baixa podem conter substâncias tóxicas com baixa capacidade de degradação. Foi possível recomendar a aplicação das melhores práticas operacionais, incluindo a segregação dos efluentes brutos ou um pré-tratamento com base nos resultados de ecotoxicidade e índice de biodegradabilidade. O reúso de água também foi abordado, indicando fontes e oportunidades de reutilização. Testes de ozonização também foram conduzidos nas águas pluviais dos terminais químicos e nos efluentes tratados das indústrias com resultados promissores. A integração da análise química e ecotoxicológica se mostraram uma excelente ferramenta para gestão de águas residuais nos terminais químicos, permitindo a tomada de decisão rápida para o controle da poluição e a adoção de medidas de prevenção / Wastewater control at industries and storage terminals of liquid chemical products in bulk is very difficult task due to the high turnover and great variety of organic chemicals handled and stored in their activities. Eight terminals and two chemical plants located in Santos Port, SP, Brazil had been evaluated for 10 years. More than 2,500 chemical and ecotoxicological analysis were performed in 200 samples of raw and treated effluents. Our main objective was to verify if the acute toxicity test using Vibrio fischeri could be used in the wastewater management of those facilities and show its role as a tool for pollution prevention by reducing the discharge of persistent toxic substances in estuarine systems. The indexes of biodegradability obtained by the ratio of Biochemical Oxygen Demand (BOD5) / Chemical Oxygen Demand (COD) of raw effluents indicated that 44% of the samples presented recalcitrant organic matter. Out of 86 final effluent samples analyzed, 45 (52%) presented toxic result for V. fischeri test. No correlation was observed of COD and ecotoxicity, showing that with low COD effluent may contain toxic substances with low degradation capacity. It was possible to recommend the use of best operational practices including segregation of influents or a pre-treatment based on toxicity results and index biodegradability. Water reuse was also discussed indicating sources and opportunities for reuse in these facilities. Ozonisation tests were also conducted on the rain waters collected at the terminals facilities and on the treated effluents of the industries, showing promising results. The integration of chemical and ecotoxicity analysis turned out to be an excellent tool for wastewater management in chemical terminals, allowing rapid decision making for pollution control and prevention measures
203

Irrigação com efluente de esgoto tratado na cultura da laranja: implicações nas propriedades físicas e químicas de um argissolo vermelho amarelo distrófico típico / Irrigação com efluente de esgoto tratado na cultura da laranja: implicações nas propriedades físicas e químicas de um ARGISSOLO VERMELHO AMARELO distrófico típico

Silva, Marcos Schaaf Teixeira da 19 May 2009 (has links)
A crise da água, o aumento de esgoto domésticos gerado em estações de tratamentos e o despejo destes efluentes em corpos d\'água vêm sugerindo novas soluções para esses problemas. A disposição de água residuária tratada em solos implica na reciclagem de matéria orgânica e dos nutrientes, atuando como um processo complementar ao tratamento dessas águas. Rica em nutrientes principalmente N (nitrogênio), P (fósforo) e Na (sódio), a água residual tratada vem sendo utilizada na agricultura, utilizando critérios técnicos, como fonte de nutrientes para diversas culturas. Diante deste contexto, o objetivo deste trabalho foi analisar os possíveis efeitos da irrigação com efluente tratado em algumas propriedades químicas e físicas de um solo cultivado com laranja. A área experimental esta situada ao lado da Estação de Tratamento de Esgoto (ETE) do Ribeirão Piracicamirim que se localiza nas margens da rodovia \"Luiz de Queiroz\" no município de Piracicaba-SP. Os tratamentos aplicados foram relacionados ao percentual de umidade da capacidade de campo variando em T100%, T125%, T150%, T200% e TSI (tratamento sem irrigação). O delineamento experimental utilizado foi o de blocos inteiramente casualizados com parcelas subdivididas no tempo, com três repetições. A adubação realizada foi a de metade da dose recomendada para a cultura da laranja. Em todo o estudo as amostragens de solo foram realizadas nas camadas 0-10, 10-20, 20-40, 40-60, 60-80 e 80-100, enquanto que as amostragens de solução do solo foram realizadas nas profundidades 30, 100 e 200 cm. As variáveis químicas determinadas no solo foram: pH, H + Al, Al, Na, K, Ca e Mg. Em solução do solo as variáveis determinadas foram: pH, CE, Al, Na, K, Ca e Mg. As variáveis físicas determinadas foram: fração granulométrica e grau de dispersão de argilas. O efluente de esgoto tratado (EET) utilizado apresenta baixas concentrações de Ca, Mg, Na, K, Al, CE e RAS quando comparado com valores encontrados na literatura. Por esse fato, o EET apresenta menor potencial de alterações nas propriedades químicas e físicas do solo. O teor de sódio trocável e PST aumentaram no decorrer do experimento, enquanto a concentração de sódio na solução do solo diminuiu. O cálcio trocável no solo sofreu diminuição dos teores nas camadas superficiais, e aumento nas camadas subsuperficias. As perspectivas da irrigação de efluente de esgoto tratado na cultura da laranja são promissoras, haja vista a importância da cultura no cenário brasileiro e mundial. No entanto, estudos de longo prazo são necessários a fim de monitorar os possíveis impactos que a irrigação de EET possa ocasionar na estrutura do solo. / The crisis of the water, the sewage domestic increase generated in stations of treatments and the spilling of these effluents in bodies of water are suggesting new solutions for those problems. The disposition of wastewater treated in soils implicate in the nutrient and organic matter recycling, acting as a complementary process to the treatment of those waters. Rich in nutrients mainly N (Nitrogen), P (Phosphorus) and Na (Sodium) the treated wastewater has been used in the agriculture through technical criteria as source of nutrients for several crops. Before this context, the objective of this work was to analyze the possible effects of the irrigation with effluent treated in some chemical and physical properties of a soil cultivated with Orange. The experimental area located her beside the Station of Sewage Treatment (SST) Piracicamirim that is located in the margins of the highway \"Luiz de Queiroz\" in the municipal district of Piracicaba, São Paulo State. The applied treatments were related to the percentile of humidity of the field capacity varying in T100%, T125%, T150%, T200% and TSI (treatment without irrigation). The experimental design was a split plot scheme of randomized blocks subdivided in time, with five treatments and three repetitions. The accomplished fertilization was the one of half of the dose recommends for the orange crop. In whole the study the soil samplings were accomplished in the layers 0-10, 10-20, 20-40, 40-60, 60-80 and 80-100, while the samplings of soil solution were accomplished in the depths 30, 100 and 200 cm. The chemical variables determined in the soil were pH, H + Al, Al, Na, K, Ca and Mg. In soil solution the variables were pH, CE, Al, Na, K, Ca and Mg. The certain physical variables were fraction particle sizing and degree of clay dispersion. The sewage effluent treated (SET) used presents low concentrations of Ca, Mg, In the, K, Al, CE and RAS when compared with values found in the literature. For that fact, SET present potential minor of alterations in the chemical and physical properties of the soil. The exchangeable sodium and PST increased in elapsing of the experiment, while the concentration of sodium in the soil solution decreased. The exchangeable calcium in the soil suffered decrease in the superficial layers, and increase in the subsuperficial layers. The perspectives of the irrigation of SET in the orange crop are promising, have seen the importance of the culture in the Brazilian and world scenery. However, it is suggested studies of long period in order to monitor the possible impacts to cause in the structure of the soil.
204

Parâmetros de tratabilidade em sistemas de alagados construídos aplicado ao reuso de resíduos de dessalinização

Zaika, Marin Gadens Berton 10 April 2018 (has links)
Submitted by Angela Maria de Oliveira (amolivei@uepg.br) on 2018-06-18T17:08:54Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Zaika, Marina Gadens.pdf: 3417069 bytes, checksum: e7a555d3e211bdb7368517e8e8789617 (MD5) / Made available in DSpace on 2018-06-18T17:08:54Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Zaika, Marina Gadens.pdf: 3417069 bytes, checksum: e7a555d3e211bdb7368517e8e8789617 (MD5) Previous issue date: 2018-04-10 / A pesquisa teve como objetivo a avaliação dos parâmetros de tratabilidade, designados assim, como as variáveis, fatores, configurações hidráulicas e de operação, que por hipótese, potencialmente oferecessem influência no processo de melhoria da qualidade da água residuária (concentrado salino) decorrente da dessalinização por ultrafiltração e osmose reversa, através da aplicação de Sistemas Alagados Construídos, cultivados com capim-elefante (Pennisetum purpureum, Schum.). Os estudos foram conduzidos em escala de bancada, dentro de uma estufa agrícola semi-climatizada. Foram confeccionadas doze unidades experimentais, e estabelecidos quatro configurações de tratamento com três repetições cada, operadas e monitoradas durante cinco meses, variando em função da operação do sistema, se de fluxo contínuo ou de regime estático, e também no tempo de detenção hidráulica de três ou quatro dias. Amostras de água foram coletadas na entrada e na saída de cada unidade, e foram analisados em laboratório para a caracterização físico-química e monitoramento dos parâmetros: pH, alcalinidade, oxigênio dissolvido, turbidez, salinidade, dureza, cálcio, cloretos, sulfatos, condutividade elétrica, sólidos dissolvidos totais e demanda química de oxigênio. Os resultados foram submetidos à análise de variância e teste de Tukey, em nível de 95% de confiança, utilizando-se o programa estatístico SISVAR. Os sistemas que foram submetidos ao regime estático, com tempo de detenção hidráulica de quatro dias, nas três primeiras semanas de operação, mostraram ser mais eficientes na remoção média de salinidade (53,1%), dureza (69,2%), cálcio (66,7%), cloreto (44,5%), condutividade elétrica (40,7%) e sólidos dissolvidos totais (86,7%). A planta conseguiu absorver 0,25% do íon sódio pelas suas raízes para a sua nutrição, segundo resultados de ensaio de microscopia eletrônica. / The aim of this research was to evaluate the treatability parameters, which were defined as variables, factors, hydraulic and operating configurations, which, by hypothesis, could potentially influence the process of improving the quality of wastewater (brine) resulting from desalination by ultrafiltration and reverse osmosis, through the application of Constructed Flooded Systems, cultivated with elephantgrass (Pennisetum purpureum, Schum.). The studies were conducted on bench scale, within a semi-heated agricultural greenhouse. Twelve experimental units were established, and four treatment configurations were established with three replicates each, operated and monitored for five months, varying according to the operation of the system, whether continuous or static, and also in the hydraulic holding time of three or four days. Samples of water were collected at the entrance and exit of each unit, and were analyzed in the laboratory for the physico-chemical characterization and monitoring of parameters: pH, alkalinity, dissolved oxygen, turbidity, salinity, hardness, calcium, chlorides, sulfates, conductivity total dissolved solids and chemical oxygen demand. The results were submitted to analysis of variance and Tukey's test, at a 95% confidence level, using the statistical program SISVAR. The systems that were submitted to the static regime, with hydraulic detention time of four days, during the first three weeks of operation, showed to be more efficient in the average removal of salinity (53.1%), hardness (69.2%), calcium (66.7%), chloride (44.5%), electrical conductivity (40.7%) and total dissolved solids (86.7%). The plant was able to absorb 0.25% of the sodium ion by its roots for its nutrition, according to results of the electron microscopy.
205

Aplicação da metodologia de análise de perigo e pontos críticos de controle na disposição de efluentes tratados em solos tropicais e seu potencial uso agrícola / Application of risk analysis methodology and critical control points at the disposal of treated effluent in tropical soils and their potential agricultural use.

Santos, Jeferson Gaspar dos 07 June 2016 (has links)
Introdução - A prática de reúso pela aplicação de esgotos tratados na agricultura atualmente é considerada parte integrante dos recursos hídricos por muitas nações. No entanto, oferece riscos à saúde da população pela presença de bactérias, cistos de protozoários, ovos de helmintos e vírus, capazes de sobreviver por longos períodos em ambientes desfavoráveis e apresentarem um curto tempo entre a infecção e o desenvolvimento da doença. Objetivo - Estabelecer medidas preventivas para o lançamento de efluentes nos ecossistemas aquáticos, controle sanitário na redução de patógenos transmitidos por águas contaminadas e a disposição de efluentes tratados em solos tropicais como ferramentas de auxílio do manejo integrado dos recursos hídricos em bacias hidrográficas, por meio do uso de metodologia de gerenciamento de risco com aplicação do Sistema APPCC, em um conjunto de tecnologias na produção de efluente tratado de esgoto de origem doméstica para avaliar o potencial de emprego em solos agrícolas. Métodos - A pesquisa foi desenvolvida na estação de tratamento de esgoto e no campo experimental para pesquisas de utilização de efluente na agricultura no município de Lins. Os indicadores biológicos estudados e os pontos de amostragem foram determinados através da utilização da metodologia de controle de qualidade Análise de Perigos e Pontos Críticos de Controle (APPCC). Foram coletadas amostras do solo irrigado e dos poços de monitoramento do lençol freático. As amostras foram submetidas a análises físico-químicas, microbiológicas e parasitológicas. Aos resultados obtidos foi aplicada a Avaliação Quantitativa do Risco Microbiológico, para a determinação do risco anual de infecção. Resultados - O efluente final apresentou concentrações médias de 8,13x105 NMP/100 mL de coliformes totais e 4,69x105 NMP/100 mL de Escherichia coli, não sendo observados ovos de helmintos. O solo apresentou maior concentração de coliformes totais e E. coli na camada superficial 1,01x106 e 8,70x103, diminuindo ao longo da profundidade. Os ovos de helmintos foram encontrados entre a superfície e os 15 cm de profundidade em concentrações entre 0,07 e 0,87 ovos/g de peso seco. Foi constatada a presença de adenovírus em concentração de 3,56x105 cópias genômicas/g entre os 5 e 10 cm de profundidade em 2015. Nos poços de monitoramento foram constatadas concentrações de coliformes totais variando entre < 1,00 e 1,01x103 NMP/100 mL e E. coli entre <1,00 e 1,00x100 NMP/100 mL. Não foi observada a presença de vírus entéricos. O risco anual de infecção estimado para E. coli no efluente final foi 1,02x10-2 pppa, no solo variou entre 2,68x10-3 e 7,59x10-3 pppa e nos poços de monitoramento variou entre 1,42x10-8e 4,38x10-9 pppa. Para os ovos de helmintos observados no efluente do tratamento primário o risco anual de infecção calculado foi 4,04x10-2 pppa e no solo variou entre 9,57x10-1 e 9,76x10-1 pppa. Conclusões No período da pesquisa, as amostras dos sistemas de tratamento de esgoto e de irrigação demonstraram atender as expectativas de remoção de patógenos condizentes aos seus parâmetros de projeto, havendo restrições para seu lançamento em corpos hídricos e aplicação na agricultura. O solo mostrou capacidade de retenção dos organismos patogênicos nos primeiros 60 cm de profundidade, reduzindo as suas concentrações a níveis inferiores a 1,00 NMP/100 mL nos aquíferos. / Introduction - Currently, the practice of reuse through the application of treated sewage in agriculture considers an integral part of water resources for many nations. However, threatens the health of the population by the presence of bacteria, protozoan cysts, helminth eggs and viruses able to survive for long periods in harsh environments and present a short time between infection and development of disease. Objective - Establish preventive measures for the release of effluents on aquatic ecosystems, sanitary control in the reduction of pathogens transmitted by contaminated water and the disposal of treated effluent in tropical soils as aid tools in integrated management of water resources in river basins. For this purpose it was employed as risk management methodology the Hazard Analysis and Critical Control Points system (HACCP) in a set of technologies in the treated effluent production of domestic sewage to assess the employment potential in agricultural soils. Methods - The study was conducted in the sewage treatment plant and in an adjoining experimental field situated at Lins city. The biological indicators and the sampling points were determined by using the quality control methodology Hazard Analysis and Critical Control Points (HACCP). Samples of irrigated soil and groundwater monitoring wells were collected. The samples were subjected to analysis, physical-chemical, microbiological and parasitological. The results obtained was applied to Quantitative Microbial Risk Assessment (QRMA), for determining the annual risk of infection. Results - The final effluent presented average concentrations of 8.13x105 MPN / 100 mL of total coliforms and 4.69x105 MPN / 100 mL of Escherichia coli, not being observed helminth eggs. The soil showed the highest concentration of total coliforms and E. coli in the surface layer and 1.01x106 8.70x103, decreasing along the depth. Eggs from helminths were found between the surface and 15 cm depth in concentrations from 0.07 to 0.87 eggs / g dry weight. It was found the presence of adenovirus in concentration 3.56x105 genomic copies / g between 5 and 10 cm depth in 2015. In monitoring wells total coliform concentrations were found ranging from <1.00 and 1.01x103 NMP / 100 mL and E. coli between <1.00 and 1.00x100 MPN / 100 mL. It was not observed the presence of enteric viruses. The estimated annual risk of infection to E. coli in the final effluent was 1.02x10-2 pppy, soil ranged from 2.68x10-3 and 7.59x10-3 pppy and monitoring wells ranged from 1.42x10-8 e 4.38x10-9 pppy. For helminth eggs observed in the effluent from the primary treatment, the annual risk of infection was calculated 4.04x10-2 pppy and soil ranged from 9.57x10-1 and 9.76x10-1 pppy. Conclusions - During the survey period, samples of sewage and irrigation treatment systems showed meet the expectation removal of pathogens consistent to its design parameters, with restrictions on its release in water and applied in agriculture bodies. The soil of pathogenic organisms showed retention capacity in the first 60 cm depth by reducing its concentration to levels below 1.00 MPN / 100 mL in aquifers.
206

Osmose inversa aplicada no reúso da água do rio Sarapuí em processos industriais / Reverse osmosis applied in Sarapuí river water reuse in industrial processes

Raphael da Rocha Sixel 14 December 2009 (has links)
O objetivo deste estudo foi analisar o desempenho de um sistema de captação e tratamento de água do rio Sarapuí, por meio de uma estação de tratamento composta por um sistema de pré-tratamento convencional, ligado a um sistema de separação por membranas de osmose inversa, no Município de Belford Roxo RJ, instalado para fornecer água de processo a instalações industriais. Foi verificado que a água captada encontra-se em condição bastante degradada e que a unidade de tratamento removeu, em média, 97% do teor dos poluentes presentes na água, enquadrando-a nos parâmetros requeridos pelo processo industrial. Foi possível comprovar que o processo de separação por osmose inversa pode ser utilizado em escala industrial, proporcionando ganhos econômicos consideráveis, além de evitar o consumo de água potável para fins de processos industriais e, ainda, contribuir para a retirada de carga orgânica de uma fonte degradada / The objective of this study was to analyze the performance of a system to capture and treat water from Sarapuí river through a treatment system consisting of a conventional pré-treatment stage, linked to a reverse osmosis separation system membranes, in the city of Belford Roxo - RJ, installed to provide process water for industrial plants. It was found that the water is captured in highly degraded condition and the treatment plant removed an average of 97% of the pollutants in the water, fitting the parameters required by the industrial process. It could be demonstrated that the separation process by reverse osmosis can be used on an industrial scale, providing significant economic gains, and avoid the consumption of potable water for industrial processes and also contribute to the removal of organic pollutants from a degraded source
207

Avaliação do reúso agrícola de águas oleosas da indústria de petróleo tratadas por eletrofloculação e osmose inversa: efeitos na germinação, no desenvolvimento de plântulas de girassol e em atributos do solo / Evaluation of agricultural reuse of oily waters from oil industry treated by electroflocculation and reverse osmosis: effects on germination, development of sunflower seedlings and soil properties

Paulo Sérgio Alves de Souza 15 July 2015 (has links)
A presente tese de doutorado teve como objetivo estabelecer parâmetros para avaliar a viabilidade do reúso agrícola de águas oleosas da indústria de petróleo, como as águas de produção (AP) de campos de exploração onshore do semiárido nordestino, na irrigação de culturas de girassol destinadas à produção de biodiesel. A AP foi produzida sinteticamente e tratada utilizando-se as técnicas de eletrofloculação (EF) e de osmose inversa (OI). Foram analisados os efeitos da AP não tratada, tratada por EF e por EF combinada com osmose inversa (EF+OI) na germinação, desenvolvimento e produção de biomassa de plântulas de girassol e também nos atributos de um solo característico do semiárido nordestino. Na melhor condição operacional do tratamento da AP por EF (28,6 A m-2 durante 4 min.) foram obtidas eficiências de remoção de óleos e graxas (O&G), demanda química de oxigênio (DQO), cor e turbidez superiores a 95%. O tratamento EF+OI promoveu a remoção do excesso de salinidade e de ferro oriundo da etapa de EF, enquadrando-se esses parâmetros dentro de níveis de referência recomendados para água de irrigação. Níveis de O&G e DQO superiores, respectivamente, a 337 mg L-1 e 1.321 mg O2 L-1 na AP bruta produziram efeitos tóxicos, reduzindo-se o índice de velocidade de germinação (IVG) e o percentual de plântulas normais do girassol. Por outro lado, os efluentes tratados por EF e EF+OI produziram efeitos similares no percentual de sementes germinadas, no IVG, no percentual de plântulas normais e na produção de biomassa do girassol. O uso da AP tratada por EF, com ou sem diluição, contribuiu significativamente para o aumento da salinidade e dos teores de sódio do solo, diferentemente da tratada por EF+OI, que produziu efeitos similares ao do controle (água destilada) / This doctoral thesis aimed to provide subsidies to assess the viability of the agricultural reuse of oily water from oil industry, such as oilfield produced water (AP) from onshore exploration fields of northeast brazilian semi-arid, in inedible irrigation such as sunflower crops intended for biodiesel production. AP was produced synthetically and treated using the electroflocculation (EF) and reverse osmosis (OI) techniques. The effects of untreated AP, AP treated by EF and AP treated by EF combined with reverse osmosis (EF+OI) in germination, growth and biomass production of sunflower seedlings and also in the attributes of a characteristic soil of the northeastern brazilian semiarid were analyzed. In the best EF treatment operating condition (28.6 A m-2 during 4 min.) Oil and grease (O&G), chemical oxygen demand (COD), color and turbidity removal efficiencies obtained were higher than 95%. EF+OI treatment promoted the removal of salinity in excess and iron derived from EF step, fitting these parameters within the recommended reference levels for irrigation water. O&G and COD levels higher than, respectively, 337 mg L-1 and 1,321 mgO2 L-1 in raw AP produced toxic effects, reducing the germination speed index (IVG) and the percentage of normal sunflower seedlings. On the other hand, the use of EF+OI and EF treated effluent has produced similar effects on the percentage of germinated seeds, IVG, percentage of normal seedlings and biomass production of sunflower. The use of AP treated by EF, with or without dilution, contributed significantly to the increase in soil salinity and sodium contents. On the other hand, AP treated by EF+OI, has produced similar effects to the control (distilled water)
208

Estudo da demanda de água não potável e desenvolvimento de um sistema de reúso de água cinza para habitações de interesse social

Silva, Léa Marina 22 February 2013 (has links)
Made available in DSpace on 2016-12-23T14:04:29Z (GMT). No. of bitstreams: 1 Lea Marina Silva.pdf: 9837499 bytes, checksum: d2a3d5ef17c6b5b733efab787b6d3ed7 (MD5) Previous issue date: 2013-02-22 / This work studies the demand for unsafe drinking water and the development of a system for reuse of greywater for social interest housing (SIH). The study presents a characterization of the profile of water consumption in a community of SIH the Jabaeté Residential in Vila Velha (ES). Investigates what water conservation actions best apply in everyday community in question, analyzing the reuse compared to the other interventions evaluated and finally, proposes some possible configurations of reuse systems in this community, through architectural design, as preliminary studies. These studies indicated an average consumption of water in SIH studied of 79 l.p-1d-1 and other indexes relating to the demand for potable water in every household activity (the most representative is the laundry, responsible for approximately 41% for total consumption). The methodology was based on questionnaires and monitoring of water consumption by reading water meters. By applying a method of decision support Analytic Hierarchy Process (AHP) it was determined the advantage of practices such as the use of dual discharge and segregating urine basin on the reuse of greywater. Furthermore projectual studies were performed of two types of configurations reuse systems: the decentralized and semi decentralized system, for which it was budgeted deployment costs. Observed economic advantage from adopting the semi decentralized, whose implementation can be up to 112% cheaper than the decentralized system / Este trabalho estuda a demanda de água não potável e o desenvolvimento de um sistema de reúso de águas cinza para Habitações de Interesse Social (HIS). Para tanto, realiza a caracterização do perfil de consumo de água em uma comunidade formada por HIS o Residencial Jabaeté, em Vila Velha (ES); investiga quais ações de conservação de água melhor se aplicam no cotidiano da comunidade em questão, analisando o reúso frente às demais ações avaliadas; e, por fim, propõe algumas configurações possíveis de sistemas de reúso nessa comunidade por meio de projeto arquitetônico, no nível de estudo preliminar. Tais estudos apontaram um consumo médio de água nas HIS estudadas de 79 l/hab. dia e demais índices relativos à demanda de água potável em cada atividade doméstica (a mais representativa é a lavagem de roupas, responsável por aproximadamente 41% do consumo total). A metodologia utilizada foi aplicação de questionários e monitoramento do consumo de água pela leitura de hidrômetros. Através da aplicação de um método de suporte à decisão o Analytic Hierarchy Process (AHP), determinou-se a vantagem de práticas como uso de descarga dual e bacia segregadora de urina sobre a prática do reúso de água cinza. Além disso, foram realizados estudos projetuais de dois tipos de configurações de sistemas de reúso: o sistema descentralizado e o sistema semi-descentralizado, para os quais foram orçados os custos de implantação. Observou-se a vantagem econômica da adoção do sistema semi-descentralizado, cuja implantação pode ser até 112% mais barata que o sistema descentralizado
209

Aproveitamento da água residual do processamento do pescado em irrigação / Reuse of fish processing wastewater in irrigation

Felipe Morais Del Lama 08 November 2018 (has links)
A água residual do processamento do pescado contém elevados teores de matéria orgânica, íons e microrganismos. Devido a essa composição, há a necessidade de tratamento antes do retorno do efluente aos corpos hídricos ou ao meio ambiente. Mesmo após o tratamento, ainda pode haver contaminantes presentes no efluente tratado. Desse modo, práticas sustentáveis de gerenciamento de resíduos, tais como o reúso destes na agricultura, mostram-se adicionais ao tratamento e alternativas ao lançamento do material residual nos diferentes ecossistemas. O objetivo deste trabalho consistiu, inicialmente, em caracterizar química, física e microbiologicamente a água residual proveniente de uma indústria que realiza o beneficiamento de tilápia (Oreochromis niloticus), bem como do efluente tratado, oriundo de uma estação pertencente à própria indústria. Observou-se uma eficiência média de remoção de 90% da matéria orgânica. A concentração microbiana, todavia, apresentou aumento considerável no efluente tratado, tendo sido observado maior número de colônias de Escherichia coli. Ademais, esse mesmo material líquido apresentou concentração média de 123,4 mg/L de nitrogênio e 10,55 mg/L de fósforo, valores considerados elevados. Isso pode ser explicado pela adição inadequada de outros resíduos presentes na indústria, como dejetos humanos, às etapas de tratamento. Realizaram-se, posteriormente, ensaios de irrigação em plantas e sementes de alface (Lactuca sativa var.crispa), empregando-se cada resíduo líquido nas concentrações de 25%, 50%, 75% e 100%. Não houve efeitos adversos ao potencial fisiológico das sementes. Para as plantas cultivadas em substrato de argila, o aumento da concentração dos efluentes aplicados acarretou o acúmulo do íon cloreto (Cl-) nas alfaces. Nesse contexto, constataram-se correlações negativas entre o aumento da concentração de cloreto nos tecidos vegetais, a bioamassa e o crescimento da parte aérea e do sistema radicular. Observou-se, ainda, o aumento da taxa de mortalidade vegetal nos tratamentos irrigados com água residual, à medida que se aumentaram as concentrações desse resíduo. Os resultados referentes à irrigação permitem concluir que o efluente tratado, nas concentrações de 25% e 50%, possibilitou melhor desempenho agronômico. As análises microbiológicas das plantas irrigadas com o efluente em tais concentrações, por sua vez, não mostraram a presença de bactérias patogênicas constantes na legislação brasileira. Apesar disso, melhor gerenciamento das etapas do tratamento dos efluentes faz-se necessário, a fim de que a prática de reúso agrícola seja segura e permita geração de receitas, quesitos estes indispensáveis para a maior ecoeficiência das empresas / Fish processing wastewater contains high levels of organic matter, ions and microorganisms. Because of this composition, it is necessary to treat this effluent before its return to water bodies or the environment. Despite the treatment, there can be some remaining contaminants in the treated wastewater. Thus, sustainable practices regarding the wastes management, such as their reuse in agriculture, turn out to be an additional option to the treatment and an alternative to the disposal of these compounds in different ecosystems. The objective of this work was initially to perform chemical, physical and microbiological characterizations of a raw wastewater coming from a tilapia (Oreochromis niloticus) processing plant as well as the treated wastewater. The latter was collected from a waste treatment facility located beside and belonging to this same industry. There was a removal efficiency of 90% in organic matter. Nevertheless, bacteria concentration, mainly Escherichia coli, increased in the treated wastewater. Furthermore, this same liquid waste presented a medium concentration of 123.4 mg/L in nitrogen, and 10.55 mg/L in phosphorus, values considered important. These facts can be explained by the inappropriate addition, during the treatment stages, of other wastes present in the industry like human excrements. Secondly, irrigation trials were performed in lettuce (Lactuca sativa var.crispa) and its seeds by using each wastewater at concentrations of 25%, 50%, 75% and 100%. There were not any adverse effects to the seeds physiological potential. For plants which were grown in a clay substrate, the increase in the applied effluents caused lettuce to cumulate chloride (Cl-). In this respect, negative correlations between the chloride concentration in plants tissues, biomass, and shoot and root growth, were observed. There was still an increase in the plants mortality rate in lettuce irrigated with raw wastewater as the concentrations of this effluent became greater. These tests showed that the treated wastewater at concentrations of 25% and 50% had the best agronomic performance. The microbiological analyses of these treatments in turn did not reveal the presence of pathogenic bacteria present in the Brazilian laws. Despite this fact, a better management of the treatment stages is compulsory in order to achieve a safer wastewater reuse. Moreover, there can be a production of incomes, which represents an asset for ecoefficient companies
210

Tratamento de efluentes da produção de tintas industriais, automotivas e de  repintura por irradiação com feixe de elétrons / Treatment of effluent from industrial automotive and refinish paints by electron beam irradiation

Fernando Codelo Nascimento 09 September 2013 (has links)
Tinta pode ser conceituada como uma película ou camada de polímero utilizada para proteger, sinalizar e iluminar ou mesmo para embelezar o substrato sobre o qual ela é aplicada. Basicamente, esta mistura polimérica é formada por elementos, tais como: resinas, pigmentos, cargas, solventes e aditivos. Os resíduos e o efluente líquido gerados na produção de tintas devem ser tratados de modo que não causem contaminação de rios e das nascentes de água. A reutilização do efluente tratado é uma das possibilidades que deve ser considerada a fim de minimizar os impactos ambientais e reduzir o uso de recursos naturais. Processos de oxidação química são promissores para a degradação de compostos orgânicos tóxicos. O caminho mais eficiente para a oxidação é o ataque pelo radical hidroxila (OH), por meio do processo de oxidação avançada, POA. Um dos exemplos de POA é o que faz uso de aceleradores de feixe de elétrons, adotado por vários países para a remoção de compostos orgânicos. O objetivo deste estudo é aplicar o POA por radiação ionizante para o tratamento do efluente da fabricação de tintas para repintura automotiva, industrial e automotivo. A metodologia utilizada foi um estudo de caso, desenvolvido por meio do processamento com feixe de elétrons aplicados a esses efluentes de indústria de tintas. O estudo foi realizado em três fases. Na primeira, aplicou-se 10 kGy, 30 kGy e 50 kGy de dose absorvida; na segunda, 50 kGy, 80 kGy e 100 kGy, e, na última fase, foi aplicada nas amostras uma dose de 50 kGy e dopadas com 0,005%, 0,05% e 0,5% de peróxido de hidrogénio em volume. Os principais resultados demonstraram uma redução média de cerca de 10% da Demanda Química de Oxigênio, DQO e cerca de 25% da Demanda Bioquímica de Oxigênio, DBO. Os padrões de efluentes finais definidos pelos requisitos legais, em especial pelo Decreto Estadual 8468/1976. para o descarte do corpo no rio ou reutilização em aplicações industriais, foram atendidos. / Paint can be conceptualized as a film or a layer of polymer, to protect, to signal and to illuminate or even to embellish the substrate on which it is applied. Basically, this polymeric compound is formed by elements such as: resin, pigments, fillers, solvents, and additives. Waste and wastewater generated in the production of paint, have to be treated so they do not cause the contamination of rivers and springs water. The reuse of the treated effluent is one of the possibilities that should be considered in order to minimize the environmental impacts and to reduce the use of natural resources. Chemical oxidation processes are promising for degradation of toxic organic compounds. The most efficient path for the oxidation is the attack by hydroxyl radical (OH), and the Advanced Oxidation Process, AOP, using electron beam accelerators have been adopted by several countries for the removal of organic compounds. The aim of this study is to apply the AOP by ionizing radiation to treat the effluent from the manufacture of automotive, automotive refinish and industrial paints. The methodology used was a case study, developed through the electron beam processing of these effluents. The study was developed in three phases: in the first one it was applied 10 kGy, 30 kGy and 50 kGy of absorbed dose, in the second one, 50 kGy, 80 kGy and 100 kGy, and in the last one it was applied 50 kGy in samples and doped with 0.005%, 0.05% and 0.5% of hydrogen peroxide. The main results have shown an average reduction of about 10% of Chemical Oxygen Demand, COD and about 25% of Biochemical Oxygen Demand, BOD. The final effluent standards set by legal requirements for disposal of the body in the river or reuse in industrial application.

Page generated in 0.322 seconds