• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 370
  • 9
  • 3
  • Tagged with
  • 389
  • 251
  • 93
  • 74
  • 69
  • 58
  • 50
  • 50
  • 50
  • 41
  • 41
  • 38
  • 35
  • 33
  • 32
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
301

Variação espacial e temporal do microfitoplâncton e sua utilização no monitoramento da qualidade de água do Reservatório de Boa Esperança – PI / MA

MENDONÇA, Ivo Thadeu Lira 18 February 2009 (has links)
Submitted by (edna.saturno@ufrpe.br) on 2017-02-14T14:20:14Z No. of bitstreams: 1 Ivo Thadeu Lira Mendonca.pdf: 906790 bytes, checksum: 20a8319a942fd0ff9acd8bcc2c266f8c (MD5) / Made available in DSpace on 2017-02-14T14:20:14Z (GMT). No. of bitstreams: 1 Ivo Thadeu Lira Mendonca.pdf: 906790 bytes, checksum: 20a8319a942fd0ff9acd8bcc2c266f8c (MD5) Previous issue date: 2009-02-18 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Opportunist species increase their population in detriment to others that previously participated in the assemblage, changing the ecosystem structure. Such changes can be used as ecological tools in pollutant sources monitoring, because they corroborate in the description of alterations of aquatic ecosystem trophic state. Therfore, this study aimed at surveying and characterizing the planktonic algae species of Boa Esperança Hydroelectric reservoir – PI/MA, Brazil, along its extension in different seasonal periods. Four quarterly surveys were carried out, between July 2006 and April 2007, in 17 sampling stations. The biological material was obtained through vertical tows along the euphotic zone. Algae ecological strategies and associations were defined and biotic indexes applied. 189 taxons were identified, distributed among Chlorophyta (94), Bacillariophyta (41), Cyanophyta (30), Euglenophyta (13), Dinophyta (4), Chrysophyta (3), Cryptophyta (3) and Xantophyta (1). The diversities and densities showed temporal differences, although tended to be longitudinally similar. The highest diversity was found in October 2006, 4,3 bit×org-1, in BOA 04, and the lowest was found in July 2006, 0,6 bit×org-1, in BOA 17, due the density of Aulacoseira granulata. The highest density was recorded in January 2007, 114,8×103 org×L-1, in BOA 17, and the lowest in April 2007, 1,4×103 org×L-1, in BOA 02. During the study, Cyanophyta and Aulacoseira granulata (Bacillariophyta) were the algal division and the species that presented the highest densities, respectively. The indexes indicated that the environment was, predominantly, mesotrophic during the year sessions. / Espécies oportunistas aumentam sua população em detrimento de outras que, outrora participavam da comunidade, mudando a estrutura populacional. Mudanças nessa estrutura podem ser utilizadas como ferramentas ecológicas em monitoramento de fontes poluidoras, pois corroboram na descrição de alterações do estado trófico em ecossistemas aquáticos. Sendo assim, objetivou-se inventariar e caracterizar as espécies de algas planctônicas do reservatório da Hidroelétrica de Boa Esperança, PI/MA, Brasil, ao longo de sua extensão e em diferentes períodos sazonais. Foram realizadas quatro coletas trimestrais, entre julho de 2006 e abril de 2007, em 17 estações amostrais. O material biológico foi obtido através de arrastos verticais ao longo da zona eufótica. Foram definidas as associações ecológicas e calculados índices bióticos. Foram identificados 189 táxons, distribuídos entre as Chlorophyta (94), Bacillariophyta (41), Cyanophyta (30), Euglenophyta (13), Dinophyta (4), Chrysophyta (3), Cryptophyta (3) e Xantophyta (1). As diversidades e densidades apresentaram diferenças entre os períodos de coleta, embora longitudinalmente tenham tendido à homogeneidade. A maior diversidade foi encontrada em outubro/06, 4,3 bit.org-1, em BOA 04, enquanto a menor em julho/06, 0,6 bit.org-1, em BOA 17, devido a densidade de Aulacoseira granulata. A maior densidade foi observada em janeiro/07, 114,8×103 org.L-1, em BOA 17, e a menor em abril/07, 1,4×103 org.L-1, em BOA. Durante o estudo, Cyanophyta e Aulacoseira granulata (Bacillariophyta) foram a divisão algal e a espécie que apresentaram as maiores densidades, respectivamente. Os índices aplicados indicaram que o ambiente encontra-se, predominantemente, mesotrófico nos diferentes períodos do ano.
302

Utilização do sensoriamento remoto na avaliação das características limnológicas do reservatório de Itaparica, no sub-médio rio São Francisco

BIONDI, Michelle Miranda 06 February 2006 (has links)
Submitted by (edna.saturno@ufrpe.br) on 2017-02-16T16:35:44Z No. of bitstreams: 1 Michelle Miranda Biondi.pdf: 2333782 bytes, checksum: ba308bcdccee11923cf2e982d3ac74f1 (MD5) / Made available in DSpace on 2017-02-16T16:35:44Z (GMT). No. of bitstreams: 1 Michelle Miranda Biondi.pdf: 2333782 bytes, checksum: ba308bcdccee11923cf2e982d3ac74f1 (MD5) Previous issue date: 2006-02-06 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / The land inhabitants generally cause environmental impact on the marginal areas where they live in. For this reason, the evaluation of limnologic data of water bodies through remote sensing can bring information on environment aspects in a synoptic and periodic fashion. Taking into account this fact, the work aimed to study the limnologic characteristics of the Itaparica reservoir, São Francisco River, Bahia state, Brazil. Interpretation of orbital images was used to provide information on the local hydrologic characteristics. These satellite images were integrated with in loco data that posed optically active character. The results showed that urban organic loads (high values orthophosphate) and chemical fertilizers (high values ammonia) originating from soil runoff in irrigated areas, along with gallery forest degradation and soil erosion, were the main factors influencing the water’s physical and chemical characteristics. Such information was utilized to evaluate the environmental alterations that took place in the area. On the otherhand, the results also showed that remote sensing, with sensors Landsat series, has drawbacks regarding spectrometric studies on water. Therefore, further studies are needed to boost this research field. / As atuações antrópicas das populações de áreas marginais aos corpos d’água, comumente geram alterações ambientais no entorno. Neste contexto, as características limnológicas de um corpo d’água, avaliadas sob a ótica do sensoriamento remoto, que atua como uma ferramenta suporte, possibilitam a análise ambiental de uma região. Assim, foi realizado o estudo das características limnológicas do reservatório de Itaparica - Rio São Francisco, utilizando-se, para este fim, a interpretação de imagens orbitais que possibilitem a extração de informações sobre os principais fatores condicionantes às alterações limnológicas apresentadas no local. As informações extraídas da imagem de satélite foram integradas com os parâmetros físico-químicos coletados in loco, que apresentaram caráter opticamente ativo. Após a execução deste trabalho, observou-se que os principais influenciadores das alterações físico-químicas na água, originaram-se das descargas orgânicas geradas por centros urbanos (altos valores em ortofosfato), e fertilização (altos valores em amônia) através do escoamento superficial do solo, acentuado pela degradação das matas ciliares e conseqüente erosão do solo. Assim, as informações obtidas possibilitaram uma avaliação macro das alterações ambientais ocorridas na área de estudo. Entretanto, pôde-se verificar que o sensoriamento remoto, com uso dos sensores da série Landsat, apresenta-se limitado para estudo do alvo água, principalmente no que tange a aspectos espectrométricos, necessitando ampliação e disseminação destas pesquisas aplicadas.
303

Programação linear com controle de risco para o planejamento da operação do SIN / Linear programming with risk control for the operation planning of SIN

Rui Bertho Junior 08 March 2013 (has links)
O planejamento da operação energética do sistema interligado nacional brasileiro é realizado por uma cadeia de modelos computacionais de otimização e simulação da operação. Entretanto, o risco de déficit, um importante indicador de segurança energética no setor elétrico, é tratado como uma variável de saída dos modelos computacionais. No planejamento de médio prazo é utilizado o software NEWAVE, que utiliza uma representação agregada em subsistemas equivalentes. Este trabalho propõe a implementação de um modelo de otimização linear para o planejamento da operação de médio prazo capaz de considerar o risco de déficit em sua formulação. Para o controle de risco de déficit, é proposta a utilização da métrica de risco conhecida por CVaR (Conditional Value at Risk), por se caracterizar como uma métrica de risco coerente, além de poder ser implementada por meio de um conjunto de restrições lineares. / The energetic operation planning of the Brazilian interconnected system is performed by a chain of computational models for the system optimization and simulation. However, the deficit risk, an important energy security indicator for the electric sector, is treated as an output variable on the computational models. In the medium-term of the energetic planning is used the software NEWAVE, which uses equivalent systems on aggregated representation. This work proposes the implementation of a linear optimization model for the medium-term of the energetic planning able to consider the deficit risk in its own formulation. To control the deficit risk is proposed the use of the risk metric known as CVaR (Conditional Value at Risk), because it is characterized as a coherent risk metric, and can be implemented through a set of linear constraints.
304

Estudo multidisciplinar da evolução ambiental do Reservatório de Salto Grande, Americana, SP, a partir de análises multiproxies geoquímicos, de magnetismo ambiental e biológicos (Tecamebas) / Multidisciplinary study of the environmental evolution of the Salto Grande Reservoir, Americana, SP, from analysis of geochemical multiproxies, environmental magnetism and thecamoebians

Maria Laura Misailidis Lerena 03 October 2016 (has links)
A presente dissertação é um estudo da evolução ambiental do Reservatório de Salto Grande (RSG), Americana, SP, realizado a partir de análises granulométrica, geomagnética, geoquímica (especiação fósforo e carbono, elementos traço, compostos organoclorados e hidrocarbonetos aromáticos policíclicos) e biológica (tecamebas) de amostras de um testemunho sedimentar de 233 cm. Com base nos resultados obtidos, foi possível: 1) avaliar a toxicidade dos sedimentos, de acordo com os valores-guia de qualidade de sedimentos (VGQS) TEL e PEL, fator de enriquecimento (EF) e índice de geoacumulação (Igeo) e 2) identificar cinco fácies sedimentares, ao longo do testemunho. Fácies 1, situada na base do testemunho, é constituída por lama, com baixas concentrações de elementos traço, compostos organoclorados e HPAs, presença de material radicular e ausência de tecamebas. Essa sequência sedimentar pode ser atribuída às unidades de solos e sedimentos depositados na planície aluvial do Rio Atibaia e representa a fase Préreservatório. A partir de 177 cm de profundidade rumo ao topo, passam ocorrer mais quatro fácies, indicativas dos 65 anos de existência do RSG. A Fácies 2 (transição de solo e início do reservatório) caracteriza-se pela presença de lama, com tênue estratificação plana paralela e surgimento de tecamebas (Arcella gibbosa, A. megastoma, Difflugia corona, D. oblonga, D. gramen e Centropyxis discoide aculeata). Nessa fácies não foram detectados sedimentos contaminados, segundo VGQS. Contudo, foi constatado aumento expressivo de HPAs, provavelmente relacionado a queimadas ocorridas no entorno do reservatório. Fácies 3 (Reservatório) é marcada por sucessão de camadas de lama escura, intercaladas com lama clara, associadas às variações sazonais de produtividade do reservatório. Na porção final da Fácies 2 e toda a Fácies 3, ocorrem as maiores concentrações dos elementos traço (principalmente Cu, e Cr), parâmetros geomagnéticos, PCBs, DDT e HPAs, bem como o primeiro e maior declínio das populações de tecamebas. Nessa fácies 3 os VGQS indicam a presença de sedimentos fortemente contaminados. Fácies 4 continua a apresentar sucessão de camadas escuras e claras, contudo, as concentrações dos elementos traço, parâmetros geomagnéticos, PCBs, DDT e HPAs diminuem sensivelmente e os valores de densidade e diversidade das tecamebas aumentam. Valores de Cu diminuem mas, continuam expressivos, indicando sedimentos contaminados. As oscilações da concentração de Cu podem estar relacionadas ao uso de algicidas à base de CuSO4, que são utilizados no RSG para controlar a floração de cianobactérias e macrófitas. Fácies 5, correspondente ao período mais recente da história do RSG, caracteriza-se pela presença de lama preta, contaminada por Cu, pobre em tecamebas e baixas concentrações de DDT e HPAs. As curvas de evolução dos fluxos de fósforo inorgânico, Mn e Zn apresentaram forte similaridade com as curvas de crescimento demográfico da cidade de Americana e com as variações do regime de chuvas local. Estes resultados sugerem que as variações do aporte de nutrientes no reservatório encontram relação direta com as mudanças no escoamento de água pluvial na bacia de drenagem do Atibaia e com os influxos industriais e domésticos no RSG / This works presents an environmental evolution of the Reservatório de Salto Grande (RSG), Americana, accomplished through the grain-size, geochemical (phosphorous, carbon, trace elements, organochlorines and polycyclic aromatic hydrocarbons), and biological (thecamoebians) analyses from sample of a sediment core. Based on the results it was possible to: 1) evaluate the sediments according to the Sediment Quality Guideline Values for metals and associated (SQGV), enrichment factors, and geoaccumulation index and 2) identify five sedimentary facies through the core. Facies 1 located at the base of the core is composed of muddy sediments with low concentrations of trace elements, organochlorines and PAHs, presence of small trees roots and absence of thecamoebians. This sedimentary sequence could be attributed to soil units and sediments deposited in the alluvial basin of the Atibaia river and represents the pre-reservoir succession. From 177 cm through the top of the core more 4 facies are identified, all correlated with the time span of 65 years since the inundation of the RSG. Facies 2 (transition between soil portion and the reservoir inundation) is characterized by the presence of a homogeneous mud and a thin parallel planar stratification and by the appearance of thecamoebians (Arcella gibbosa, A. megastoma, Difflugia corona, D. oblonga, D. gramen, Centropyxis discoide aculeata). In this facies no contaminants were registered according to SQGV standards. But a high concentration of PAHs was detected possibly indicative of vegetation burning. Facies 3 (Reservoir) is marked by a succession of dark mud interleaved by whitish mud likely associated to seasonal variation of primary productivity in the reservoir. At the top portion of facies 2 and the whole extension of facies 3 were found the highest concentration of trace elements (Cu, and Cr), geomagnetic parameters, PCBs, DDT and PAHs, and the first and major decline of thecamoebians populations. In this facies SQGV are indicative of highly contaminated sediments. Facies 4 continuously shows the same succession of mud and the concentrations of trace elements, geomagnetic parameters, PCBs, DDT and PAHs show a sensitive decrease, and the values of richness and abundance of thecamoebians show an increase. Although the values of Cu diminish, they still remain expressive, indicative of sediment contamination. The oscillations of Cu concentrations may be related to the use of algaecides composed of CuSO4 in order to control populations of cyanobacteria and macrophytes. Facies 5 corresponds to the last centimeters of the core and to recent periods of the history of RSG, characterized by the presence of a black mud contaminated with Cu poor in species of thecamoebians and low concentrations of PCBs, DDT and PAHs. The curves of inorganic phosphorous, Mn and Zn showed a similar pattern to the curves of demographic growth and rain fall in the city of Americana. These results suggest that the variations of nutrients income are related to the change in water flow regimes in the Atibaia river watershed and to industrial and domestic input in the RSG
305

Avaliação da concentração de radionuclídeos naturais das séries U-238 e Th-232, K-40 e caracterização química inorgânica de perfis de solo e testemunhos de sedimento da área de influência do reservatório Taiaçupeba, estado de São Paulo / Assessment of the natural radionuclides concentrations from 238U and 232Th decay series, 40K and inorganic chemical characterization of soil profiles and sediment cores in the catchment area of the Taiaçupeba reservoir, São Paulo

Joseilton Marques de Souza 11 October 2017 (has links)
O Reservatório Taiaçupeba, localizado no estado de São Paulo, na divisa dos municípios Mogi das Cruzes e Suzano, faz parte do Sistema Produtor Alto Tietê SPAT. A água deste reservatório é captada pela ETA da Sabesp para tratamento e distribuição, abastecendo 3,1 milhões de pessoas. Para se avaliar possíveis riscos à qualidade da água deste importante reservatório; foram coletados quatro perfis de solo e quatro testemunhos de sedimento na área de influência do reservatório. Este trabalho teve como objetivo avaliar a concentração de atividade dos radionuclídeos naturais 238U, 226Ra,210Pb, 232Th, 228Ra, 228Th e 40K e realizar a caracterização química inorgânica determinando os elementos As, Ba, Ce, Co, Cr, Cs, Eu, Hf, K, La, Lu, Nd, Rb, Sb, Sc, Se, Sm, Ta, Tb, Th, U, Yb e Zn no solo e sedimento marginal. As técnicas analíticas empregadas foram a espectrometria gama de alta resolução e a análise por ativação com nêutrons instrumental (INAA), repectivamente. Realisou-se a análise do fator de enriquecimento FE para avaliar a contribuição antrópica nas concentrações dos elemento químicos obtidos por INAA, utilizando como referência os valores da Crosta Continental Superior CCS. Analisou-se, também, a composição granulométrica, o conteúdo de água e o teor de matéria orgânica para auxiliar na interpretação dos resultados obtidos. Na análise granulométrica os perfis de solo apresentaram maiores percentuais de fração fina (silte + argila), enquanto que os testemunhos de sedimento apresentaram em sua maioria maiores percentuais de fração grossa (areia). Todos os perfis de solo apresentaram umidade praticamente constante, entre 10% e 20%. O sedimento apresentou variação no conteúdo de água, no geral reduzindo com a profundidade, sendo esta mais acentuada em um dos testemunhos. Em relação à matéria orgânica constatou-se maiores percentuais médios nos testemunhos de sedimento. No estudo das concentrações dos radionuclídeos naturais, verificou-se as maiores concentrações de atividade para os radionuclídeos 40K,232Th e 228Th, no solo, e 232Th e 210Pb, no sedimento. Em relação à caracterização química inorgânica do solo e sedimento foram determinados altos valores para os elementos As e Sb (40 mg.kg-1 e 2,9 mg.kg-1) quando comparados com os valores da CCS (1,5 mg.kg-1 e 0,2 mg.kg-1), respectivamente. Um dos testemunhos apresentou concentração elevadíssima para o elemento Zn (concentração máxima de 38157 mg.kg-1 e média de 6602,6 mg.kg- 1) quando comparada aos valores da crosta continental superior (71 mg.kg-1), indicando forte contribuição antrópica. Na análise do fator de enriquecimento, além dos elementos citados acima, outros elementos como Ce, Co, Cr, Cs, Eu Hf, La, Lu, Nd, Sm, Tb, Th, U e Yb também apresentaram contribuição antrópica. / The Taiaçupeba Reservoir, located in the state of São Paulo, on the border of the municipalities of Mogi das Cruzes and Suzano, is part of the Alto Tietê Producer System - SPAT. The water from this reservoir is captured by Sabesp\'s ETA for treatment and distribution, supplying 3.1 million people. In order to evaluate possible risks to the water quality of this important reservoir, four soil profiles and four sediment cores were collected in the area of influence of the reservoir. The aim of this work was to evaluate the concentration of the natural radionuclides 238U, 226Ra, 210Pb, 232Th, 228Ra, 228Th and 40K and to perform the inorganic chemical characterization determining the elements As, Ba, Ca, Ce, Co, Cr, Cs, Eu, Fe, Hf, K, La, Lu, Na, Nd, Rb, Sb, Sc, Se, Sm, Ta, Tb, Th, U, Yb and Zn in soil profiles and marginal sediment cores. The analytical techniques used were high resolution gamma spectrometry and instrumental neutron activation analysis (INAA), respectively. The analysis of the enrichment factor - EF was performed to evaluate the anthropic contribution in the concentrations of the chemical elements obtained by INAA, using as reference the values of the Upper Continental Crust UCC. The granulometric composition, the water content and the organic matter content were also analyzed to aid in the interpretation of the obtained results. In the particle size analysis, the soil profiles presented higher percentages of fine fraction (silt + clay), while the sediment samples showed in the majority of the cores higher percentages of coarse fraction (sand). The soil samples presented almost constant moisture in all profiles, varying from 10% and 20%. The sediment cores presented variation in the water content, generally reducing with the depth. Regarding organic matter, it was observed a higher mean percentage in the the sediment cores. In the study of the natural radionuclide concentrations the highest values determined were verified for the radionuclides 40K, 232Th and 228Th in the soil samples and 232Th and 210Pb in the sediment samples. In relation to the inorganic chemical characterization of soil and sediment, high values for As and Sb elements (40 mg.kg-1 and 2.9 mg.kg-1) were determined when compared to the values of UCC (1.5 mg. kg-1 and 0.2 mg.kg-1), respectively. One of the sediment cores presented very high concentration for the element Zn (maximum concentration of 38157 mg.kg-1 and mean value of 6602.6 mg.kg-1), higher than the value of UCC (71 mg.kg-1), indicating a strong anthropogenic contribution. In the analysis of the enrichment factor, other elements such as Ce, Co, Cr, Cs, Eu Hf, La, Lu, Nd, Sm, Tb, Th, U and Yb also presented anthropogenic contribution.
306

Simulação e avaliação de um sistema de aquecimento solar de água utilizando balanço energético / Simulation and evaluation of a system of solar water heating using energy balance

Medeiros, Maurício 17 February 2012 (has links)
Made available in DSpace on 2017-07-10T15:14:45Z (GMT). No. of bitstreams: 1 Mauricio Medeiros.pdf: 2573107 bytes, checksum: 1e5a17966417b43d576f37b4837c682b (MD5) Previous issue date: 2012-02-17 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This work was developed at the State University of West of Paraná UNIOESTE, campus de Cascavel and was aimed at developing a computer program to simulate and scale, optimally, a system of solar water heating. To determine the efficiency parameters of the system were installed three solar collectors of 1.05 m2 each, brand Pro Sol, coupled to a thermal reservoir of 200 liters, containing electrical resistances auxiliary 2000 W. The system works by using thermosyphon, and was installed in a metal bracket fixed to the ground, oriented to the north at an angle of 35 degrees from the horizontal. We collected hourly data of solar radiation and water temperatures, and evaluated two scenarios. In the first scenario, it was considered system utilization auxiliary heating controlled by a thermostat, which linked and hang up the electrical resistances as the temperature of water in boiler oscillated around of temperature of consumption (40 º C). In the second scenario, it was considered the system to power auxiliary heating only in timetables of water consumption, when the water temperature in boiler was lower than the temperature of consumption. Coefficients were calculated heat loss in the solar collector and storage tank, the heat removal factor of solar collector and the overall efficiency of the heating system installed. These calculated parameters and other data collected were used in software developed for simulation and design in order to satisfactorily meet the needs of hot water consumption, and minimize the total installation costs and energy consumption. Finally, these system costs solar heating were compared to costs of an electric shower conventional. The results obtained were as follows: coefficient of heat loss in the solar collector (5,45 Wm-2ºC-1), coefficient of heat loss in the thermal reservoir (5,34 Wm-2ºC-1), removal factor heat of the solar collector (0.78) and overall system efficiency (31%). The times of return on capital invested in the solar heating system (compared to a conventional electric shower), for the two scenarios of use, were, respectively, 11.45 years and 7.81 years. / Este trabalho foi desenvolvido na Universidade Estadual do Oeste do Paraná UNIOESTE, campus de Cascavel, e teve por objetivo principal o desenvolvimento de um programa computacional para simular e dimensionar, de forma otimizada, um sistema de aquecimento solar de água. Para determinar os parâmetros de eficiência do sistema, foram instalados três coletores solares de 1,05 m2 cada, da marca Pro Sol, acoplados a um reservatório térmico de 200 litros, contendo resistências elétricas auxiliares de 2000 W. O sistema utilizado funciona por termossifão, e foi instalado em um suporte metálico fixado ao solo, com orientação para o norte, num ângulo de 35º em relação à horizontal. Foram coletados dados horários de radiação solar e temperaturas da água, e avaliados dois cenários. No primeiro cenário, considerou-se a utilização do sistema de aquecimento auxiliar controlado por um termostato, que ligava e desligava as resistências elétricas conforme a temperatura da água no boiler oscilava em torno da temperatura de consumo (40ºC). No segundo cenário, considerou-se o acionamento do sistema de aquecimento auxiliar somente nos horários de consumo de água, quando a temperatura da água no boiler estivesse menor que a temperatura de consumo. Foram calculados os coeficientes de perda de calor no coletor solar e no reservatório térmico, o fator de remoção de calor no coletor solar e a eficiência global do sistema de aquecimento instalado. Esses parâmetros calculados, e os demais dados coletados, foram utilizados no software desenvolvido para simulação e dimensionamento, de maneira a atender satisfatoriamente às necessidades de consumo de água quente, e minimizar os custos totais de instalação e consumo de energia elétrica. Por fim, esses custos do sistema de aquecimento solar foram comparados aos custos de um chuveiro elétrico convencional. Os resultados obtidos foram os seguintes: coeficiente de perda de calor no coletor solar (5,45 Wm-2ºC-1), coeficiente de perda de calor no reservatório térmico (5,34 Wm-2ºC-1), fator de emoção de calor do coletor solar (0,78) e eficiência global do sistema (31%). Os tempos de retorno do capital investido no sistema de aquecimento solar (em comparação a um chuveiro elétrico convencional), para os dois cenários de utilização, foram de, respectivamente, 11,38 anos e 5,73 anos.
307

Programação linear com controle de risco para o planejamento da operação do SIN / Linear programming with risk control for the operation planning of SIN

Bertho Junior, Rui 08 March 2013 (has links)
O planejamento da operação energética do sistema interligado nacional brasileiro é realizado por uma cadeia de modelos computacionais de otimização e simulação da operação. Entretanto, o risco de déficit, um importante indicador de segurança energética no setor elétrico, é tratado como uma variável de saída dos modelos computacionais. No planejamento de médio prazo é utilizado o software NEWAVE, que utiliza uma representação agregada em subsistemas equivalentes. Este trabalho propõe a implementação de um modelo de otimização linear para o planejamento da operação de médio prazo capaz de considerar o risco de déficit em sua formulação. Para o controle de risco de déficit, é proposta a utilização da métrica de risco conhecida por CVaR (Conditional Value at Risk), por se caracterizar como uma métrica de risco coerente, além de poder ser implementada por meio de um conjunto de restrições lineares. / The energetic operation planning of the Brazilian interconnected system is performed by a chain of computational models for the system optimization and simulation. However, the deficit risk, an important energy security indicator for the electric sector, is treated as an output variable on the computational models. In the medium-term of the energetic planning is used the software NEWAVE, which uses equivalent systems on aggregated representation. This work proposes the implementation of a linear optimization model for the medium-term of the energetic planning able to consider the deficit risk in its own formulation. To control the deficit risk is proposed the use of the risk metric known as CVaR (Conditional Value at Risk), because it is characterized as a coherent risk metric, and can be implemented through a set of linear constraints.
308

Uso de coleiras impregnadas com deltametrina 4% em cães no controle da leishmaniose visceral

Kazimoto, Thais Aparecida 23 February 2016 (has links)
Submitted by Socorro Pontes (socorrop@ufersa.edu.br) on 2017-02-08T15:08:05Z No. of bitstreams: 1 ThaísAK_DISSERT.pdf: 1952872 bytes, checksum: d756cff8a38a02ad11767b390ea5ce27 (MD5) / Made available in DSpace on 2017-02-08T15:08:05Z (GMT). No. of bitstreams: 1 ThaísAK_DISSERT.pdf: 1952872 bytes, checksum: d756cff8a38a02ad11767b390ea5ce27 (MD5) Previous issue date: 2016-02-23 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Visceral leishmaniasis (VL) is a potentially fatal chronic disease when left untreated. In Brazil, is caused by the protozoan Leishmania infantum is transmitted primarily by sandfly Lutzomyia longipalpis, the dog as the main reservoir. The control of this disease has been in a challenge to public health, and as a proposal for a measure of control of canine VL using dog collars impregnated with deltamethrin to 4% in dogs. Thus, the research aims to assess the effectiveness of these collars on the prevalence of canine VL and infection rate of sandfly to L. infantum in endemic areas for VL. The survey was conducted in two areas equidistant from the city of Mossoró/RN, with similar environmental characteristics. In both of these areas were carried out two surveys every six months and to serologic canines are search for a year, and in a were performed only the procedures mentioned above, being named Control Area (AC) and the other, in addition to the steps mentioned earlier were also carried out two collaring dogs with collars impregnated with deltamethrin the 4% that occurred every six months This area was named “Encoleiramento” Area (AE). For diagnosis of canine VL was made DPP and ELISA. The analysis of the prevalence of canine VL was carried out through the Chi-square test and the incidence rate of the disease through the Odds ratio. For the collection of sandflies were selected three houses in each of the areas, the insects were collected monthly using CDC light traps and separated by species, sex, stage of investigation and research. The morphological identification of sandflies and the females were subjected to real-time PCR for the detection of DNA of L. infantum. With regard to prevalence and incidence rates of VL, evaluating the areas in isolation, one could observe that the use of dog collars was able to reduce the prevalence of the disease in AE and 53 to 59% reduction in the risk of illness. As the sandfly, collected the species L. longipalpis, L. evandroi, L. cortelezzii and L. migonei, with 81,8% % L. longipalpis. Positive pools were obtained from L. longipalpis of AE only during the first investigation while in AC could observe the presence of DNA of the parasite in vector in both investigations. Based on the results, the use of impregnated with deltamethrin collars to 4% has the potential to reduce the prevalence of canine VL as well as allows a reduction in at least 53% the risk of illness. It is also possible to suggest that the continued use of these dog collars can have the potential to reduce the rate of infected sandflies. Thus, impregnated with deltamethrin collars to 4% can be indicated as a control measure for the disease, together with other measures currently recommended / A leishmaniose visceral (LV) é uma doença crônica potencialmente fatal quando não tratada. No Brasil, é causada pelo protozoário Leishmania infantum é transmitida principalmente pelo flebotomíneo Lutzomyia longipalpis, tendo o cão como principal reservatório urbano. O controle desta afecção tem consistido em um desafio para a Saúde Pública, e como proposta de medida de controle da LV canina tem-se a utilização de coleiras impregnadas com deltametrina a 4% em cães. Assim, a pesquisa tem como objetivo avaliar a efetividade dessas coleiras sobre a prevalência da LV canina e taxa de infecção de flebotomíneos para L. infantum em áreas endêmicas para LV. A pesquisa foi realizada em duas áreas equidistantes do município de Mossoró/RN com características ambientais semelhantes. Em ambas as áreas foram realizados dois inquéritos sorológicos caninos semestrais e a pesquisa de flebotomíneos. Na Área Controle (AC) foram realizados os procedimentos anteriormente citados e na Área Encoleiramento (AE) foram também realizados dois encoleiramentos caninos com coleiras impregnadas com deltametrina a 4% que ocorreram a cada seis meses. Para diagnóstico da LV canina foram realizados o teste rápido DPP e ELISA. A análise da prevalência da LV canina foi realizada através do teste de Qui-quadrado e da taxa de incidência através do Odds ratio. A pesquisa de flebotomíneos teve duração de um ano em três residências de cada uma das áreas. Os insetos foram coletados mensalmente utilizando armadilhas luminosas tipo CDC e separados por espécie, sexo, primeiro ou segundo inquérito e área da pesquisa. Foi realizada a identificação morfológica dos flebotomíneos e as fêmeas foram submetidas à técnica de PCR em tempo real para a detecção de DNA de L. infantum. Com relação às taxas de prevalência e incidência da LV canina, avaliando-se as áreas isoladamente, pôde-se observar que o uso das coleiras foi capaz de reduzir a prevalência da doença na AE e reduzir em 53 a 59% o risco de adoecimento. Quanto aos flebotomíneos, foram coletadas as espécies L. longipalpis, Lutzomyia evandroi, Lutzomyia cortelezzii e Lutzomyia migonei, sendo que 81,8% destes insetos eram L. longipalpis. Foram obtidos pools positivos de L. longipalpis da AE somente durante o primeiro inquérito ao passo que na AC pôde-se observar a presença do DNA do parasita no vetor em ambos os inquéritos. Com base nos resultados, pode-se afirmar que a utilização de coleiras impregnadas com deltametrina a 4% reduziu a prevalência da LV canina, e permite reduzir em pelo menos 53% o risco de adoecimento. Também é possível sugerir que o uso contínuo destas coleiras pode ter o potencial de reduzir a taxa de flebotomíneos infectados. Dessa forma, coleiras impregnadas com deltametrina a 4% podem ser indicadas como medida de controle para a LV canina, aliada as demais medidas atualmente preconizadas / 2017-02-08
309

Caracterização de reservatórios não convencionais Shale Gas na Formação Barreirinha Bacia do Amazonas / Shale Gas Reservoir characterization in Barreirinha Formation Amazonas Basin

Siana Soares de Oliveira 16 March 2015 (has links)
Os folhelhos pretos devonianos da Formação Barreirinha caracterizamse pela alta radioatividade na porção basal, grande extensão areal, espessura e profundidade de soterramento variável que vão de exposição na superfície até mais de 3000 m. Eles são as principais rochas geradoras do sistema petrolífero convencional da Bacia do Amazonas, e recentemente foram consideradas como promissores plays de gás não convencional. Folhelhos são geralmente caracterizados por uma matriz fechada, que faz com que sejam relativamente impermeáveis em relação ao fluxo de gás, a menos que ocorram fraturas, e dependendo das suas características geológicas e geoquímicas podem funcionar com um Sistema Petrolífero autossuficiente, atuando tanto como rocha fonte, quanto como reservatório de gás (reservatório Shale Gas). Assim, o gás natural termogênico ou biogênico gerado pode ser armazenado em folhelhos ricos em matéria orgânica na forma livre, adsorvida, ou em estado dissolvido. Em contraste com os sistemas petrolíferos convencionais, reservatórios Shale Gas, possuem mecanismos de aprisionamento e armazenamento únicos, sendo necessária a utilização de técnicas de avaliações específicas. No entanto, folhelhos prolíficos geralmente podem ser reconhecidos a partir de alguns parâmetros básicos: arquitetura geológica e sedimentar, propriedades geoquímicas e petrofísicas e composição mineralógica. Tendo em vista a carência de pesquisas de caráter descritivo, com cunho exploratório dos folhelhos geradores da Formação Barreirinha, esta dissertação tem como objetivo introduzir uma metodologia de identificação de intervalos de folhelho gerador com potencial para reservatório Shale Gas. Começando com uma investigação regional sobre o contexto geológico e sedimentar, seguido de uma avaliação abrangente enfocando as características geoquímicas, petrofísicas e litofácies dos folhelhos a partir da integração de parâmetros obtidos de perfis geofísicos de poço, análises geoquímicas e aplicação dos conceitos de Estratigrafia de Sequencia. / The Devonian black shale of Barreirinha formation is characterized by high radioactivity in the basal portion, large areal extension, thickness and depth of burial variable which ranges from exposure to surface to depth greater than 3000 m. This formation contains the main source rocks of conventional petroleum system of the Amazonas Basin, and recently were considered promising unconventional gas plays. Shales are generally characterized by a closed die, which makes them relatively impervious for gas flow unless fracturing occur, and depending on their geological and geochemical characteristics they might behave as a selfcontained Petroleum System, acting as both source rock and as a gas reservoir (Shale gas reservoir). Thus, the thermogenic or biogenic gas generated can be stored in shale rich in organic matter in free form, adsorbed or dissolved state. In contrast to conventional petroleum systems, Shale Gas reservoirs, have trapping mechanisms and unique storage, requiring the use of specific assessment techniques. However, prolific shale can usually be recognized based on some basic parameters: geological and sedimentary architecture, geochemical and petrophysical properties and mineralogical composition. Given the lack of descriptive research, about the exploration potential of the Barreirinha formations shale, this dissertation aims to introduce a methodology of identification of intervals that could be potential shale gas reservoirs. Starting with a regional research about the geological and sedimentary context, followed by a comprehensive review focusing on the geochemical characteristics, petrophysical and lithofacies based on the integration of the parameters obtained by well log, geochemical analysis and application of Sequence Stratigraphy concepts.
310

EFEITO DE RESERVATÓRIO DE APROVEITAMETO DE ÁGUA DA CHUVA SOBRE REDES DE DRENAGEM PLUVIAL / EFFECT OF RAINWATER HARVESTING RESERVOIRS OVER URBAN DRAINAGE NETWORKS

Hentges, Sara Ceron 28 August 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The urban growth and the disordered occupation of cities have increased the frequency and severity of flooding in urban areas, which occur mainly due to the modification on rainwater natural infiltration, as a result of soil imperviousness increase. The use of compensatory techniques (CT) for stormwater control has been encouraged through public polices, attempting to apply for sustainable solutions to mitigate the urbanization´s impact. An alternative already widespread in some Brazilian cities is the use of micro reservoirs (MR), which temporarily store volumes from impervious areas, and gradually emptying the water stored. Along this requirement, implementation of Rainwater Harvesting Reservoirs (RHR) to non-potable purposes is often encouraged in order to reduce the consumption of drinking water for less noble purposes, and to preserve the fountainheads. Some bibliographies suggest that in addition to these benefits, the RHR can be considered a CT also, once it stores the stormwater runoff, and therefore, in some cities where the MR is required, many buildings are already using the RHR to replace it. However, there are not many conclusive studies related to the real benefits and impacts that capturing rainwater and its use have on micro drainage networks, and specifically if such technique can be considered as a compensatory one. Thus, the main objective of this research was to evaluate whether RHR can be considered as an alternative to promote the quantitative stormwater control. For that, a comparative analysis was made between the impact that RHR use generates on micro drainage flows and networks, and the impact generated on a MR containing system. Such analysis was performed through a modeling of a urban watershed from Porto Alegre / RS, with 977 ha, 30.720 standard lots and around 70 km of micro drainage networks. The simulated MRs were designed according to the Decree No. 15.371/06 of the city of Porto Alegre, which aim to control the runoff at the source and it resulted in volumes of 3.13 m³ and 3.75 m³ for rainfall project with return period of 5 and 10 years (CP-CP-TR5 and TR10), respectively, answering to the allowable flow restriction at the lot outlet (VR = 0.624 L / s). The micro drainage networks were designed for both situations, with and without MRs, for CP-TR5 and CP-TR10. For sizing of the RHRs a continuous simulation of 12 years of precipitation data and demands series for non-potable uses data was performed, both with time step equal 5 minutes, resulting in volumes of 5.000, 10.000 and 15.000 liters due to the achieved service guarantee. These volumes of RHRs replaced the MRs and new modeling were performed considering observed rainfall data real from the continuum time series. It was found that the RHRs were not effective to maintain the VR at lots outlet, and the restriction value was exceeded for several times. For the simulated time seriess only the volume of 750 m³ would be appropriate to ensure only one offense within 10 years of simulation. That occurs because must have sufficient volume to store the expected drained volume, without spillage, regardless of the reservoir storage condition. However, if there is a very large storage capacity and demands are comparatively small, the reservoir does not empty. It was found, therefore, that exists an antagonism when trying to use the RHR for two functions: runoff control and water supply for non-potable purposes demand, since the attempt to ensure the fulfillment to the first function prevents the deployment of such large volumes. Overtopping of RHRs to 12 critical simulated events committed the microdrainage networks capacity, generating flooding in the streets along several drainage network ranges. Considering the same 12 critical events and MRs in lots were identified only four overflowing and lower overflows, which ended up committing a lower extent of drainage networks. Therefore, based on analysis of the continuous simulation with RHRs, it was found that it is not possible to consider it an equivalent technique to the MRs for storm water runoff control, unless the reservation volumes are extremely high, which would make its implementation on a few square meters lot impossible. / O crescimento urbano e a ocupação desordenada das cidades têm aumentado a frequência e a severidade das enchentes em áreas urbanas, que ocorrem, principalmente, devido à modificação nas condições naturais de infiltração das águas pluviais, decorrentes do aumento da impermeabilização do solo. Em busca de soluções sustentáveis para mitigar os impactos da urbanização, as políticas públicas vêm incentivando o uso de técnicas compensatórias (TC) para o controle do escoamento superficial. Uma alternativa já difundida em algumas cidades brasileiras é o uso de microrreservatório (MR), que armazena temporariamente os volumes oriundos do escoamento das áreas impermeáveis, esvaziando gradativamente a água armazenada. Paralelamente a essa exigência, a implementação de reservatórios para o aproveitamento da água da chuva (RAAC) com fins não potáveis vem sendo incentivada, com o intuito de reduzir o consumo de água tratada para fins menos nobres e preservar os mananciais. Algumas bibliografias sugerem que além desses benefícios, o RAAC pode ser considerado igualmente uma TC, já que armazenaria o escoamento pluvial, e por essa razão, em algumas cidades onde o MR é exigido, muitas edificações já estão utilizando o RAAC em substituição a este. No entanto, verifica-se uma falta de estudos conclusivos a respeito dos reais benefícios e impactos que a captação da água da chuva e seu aproveitamento têm sobre as redes de microdrenagem pluvial e, especificamente, se esta técnica pode ser considerada como compensatória. Assim, o principal objetivo desta pesquisa foi avaliar se os RAACs podem ser considerados como medidas para o controle quantitativo do escoamento pluvial. Para isso, foi realizada uma análise comparativa do impacto que a sua utilização gera sobre as vazões e redes de microdrenagem, com o impacto gerado em um sistema com MR. A análise foi realizada mediante modelagem matemática de uma bacia hidrográfica urbana da cidade de Porto Alegre/RS, com 977 ha, 30.720 lotes padrão e cerca de 70 km de redes de microdrenagem. Os MRs simulados foram dimensionados de acordo com o Decreto n° 15.371/06 da cidade de Porto Alegre para o controle do escoamento na fonte, resultando em volumes de 3,13 m³ e 3,75 m³, para chuvas de projeto com 5 e 10 anos de período de recorrência (CP-TR5 e CP-TR10), respectivamente, atendendo à vazão de restrição permissível na saída do lote (VR = 0,624 L/s). As redes de microdrenagem foram dimensionadas para as situações que contemplaram os MRs e para a situação sem os MRs, para CP-TR5 e CP-TR10. Para o dimensionamento dos RAACs foi realizada uma simulação contínua de 12 anos de dados de chuvas e série de demandas para fins não potáveis, ambas com intervalo de tempo de 5 minutos, tendo sido determinados os volumes de 5.000, 10.000 e 15.000 litros como os mais adequados para a edificação, em razão da garantia de atendimento atingida. Esses volumes de RAACs substituíram os MRs e novas modelagens foram realizadas considerando tanto eventos de projeto, como as chuvas reais da série contínua. Verificou-se que os RAACs não são eficientes na manutenção da VR na saída dos lotes, sendo que ao longo da série história simulada a mesma foi infringida várias vezes. Para a série histórica simulada apenas um volume de 750 m³ seria adequado para garantir apenas uma infração em 10 anos da simulação. Isso ocorre porque deve haver volume de espera suficiente para armazenar os volumes escoados, sem que haja vertimento, independentemente da condição de armazenamento do reservatório; no entanto, se existe uma capacidade de armazenamento muito grande, e as demandas são comparativamente pequenas, o reservatório não esvazia. Constatou-se, dessa forma, que existe um antagonismo quando se pretende utilizar o RAAC para as duas funções: controle de escoamento superficial e garantia de atendimento à demanda com fins não potáveis, visto que a tentativa de garantir o cumprimento da primeira função inviabiliza a implantação de volumes tão grandes. O extravasamento dos RAACs para 12 eventos críticos simulados comprometeu a capacidade das redes de microdrenagem, gerando armazenamento de água nas ruas ao longo de vários trechos. Considerando os mesmos 12 eventos críticos e os MRs nos lotes foram identificados apenas 4 extravasamentos e menores vazões extravasadas, o que acabou comprometendo uma menor extensão das redes de drenagem. Portanto, com base nas análises da simulação contínua com os RAACs, verificou-se que não é possível considerá-lo uma técnica equivalente aos MRs para o controle do escoamento pluvial, a menos que os volumes de reservação sejam extremamente elevados, o que tornaria impossível a sua implementação em um lote de poucos metros quadrados.

Page generated in 0.0762 seconds