51 |
Avaliação comparativa da resistência à abrasão de resinas compostas "condensáveis", submetidas à escovação simulada, através da alteração de massa e da rugosidade superficial. / "In vitro" ëvaluation of abrasion resistance of "condensable" composite resins after toothbrushing. Wear and superficial roughness analysis.Wang, Linda 02 March 2001 (has links)
Resinas compostas "condensáveis" correspondem a uma nova categoria de material restaurador posterior especialmente desenvolvida como alternativa estética ao amálgama. O objetivo deste trabalho foi comparar algumas marcas comerciais Solitaire (So), SureFil (Su), Alert (A), Prodigy Condensable (PC) e Filtek P-60 (P-60) a dois grupos controles, Silux Plus (SP), de micropartículas, e Z100 (Z), microhíbrida, por meio de um teste in vitro de escovação simulada. Doze corpos-de-prova de cada material foram confeccionados com dimensões de 5mm de diâmetro por 3mm de espessura. Foram realizados 100.000 ciclos de escovação em uma máquina de escovação simulada, utilizando escovas dentais de cerdas macias e solução de dentifrício e água deionizada. A alteração de massa foi verificada pela diferença entre as médias de massa inicial (antes da escovação) e final (depois da escovação) em balança analítica Sartorius. A análise da rugosidade superficial em Ra foi determinada pela diferença entre as médias de cinco leituras, iniciais e finais, com um rugosímetro Hommel Tester T1000 e por meio de microscopia eletrônica de varredura. Os resultados obtidos foram submetidos à análise de ANOVA e Tukey, apresentando diferenças significantes para perda de massa e alteração de rugosidade. As resinas SureFil e Alert apresentaram menor alteração de massa (0,38% e 0,52%), enquanto Solitaire, Prodigy Condensable e Silux Plus as maiores (1,51%, 1,55%, 1,70%). Z100 e P-60 apresentaram alteração de massa intermediária às outras resinas. Diferentemente dos outros grupos, Prodigy Condensable, Solitaire e Z100 apresentaram, após a escovação, superfícies mais lisas (-0,012mm, -0,047mm e -0,065mm respectivamente), enquanto a rugosidade superficial aumentou nos demais grupos (A= 0,073mm, P-60= 0,095mm, Si= 0,158mm e Su= 0,470mm). SureFil apresentou a menor perda de massa e a maior variação de rugosidade superficial comparada às demais resinas testadas. Não houve correlação entre perda de massa e rugosidade superficial. As análises realizadas em microscopia eletrônica de varredura apresentaram-se coerentes com os resultados quantitativos obtidos. De maneira geral, as resinas compostas "condensáveis" apresentaram comportamento semelhante entre si e em relação à resina microhíbrida Z100. / "Condensable" composites resins are a category of posterior materials especially developed as an aesthetic alternative to amalgam. The aim of this research was to compare these materials by an "in vitro" abrasion test simulating toothbrushing. Solitaire (So), SureFil (Su), Alert (A), Prodigy Condensable (PC) and Filtek P-60 (P-60) were compared to two control groups, microfilleD Silux Plus (SP) and microhybrid Z100 (Z). Twelve samples of each material were prepared with 5mm in diameter and 3mm thick. The abrasion test was applied up to 100.000 cicles by an appropriate machine with soft bristles tips containing dentifrice solution and deionized water. The weight loss was detected by the differences between the initial (before toothbrushing) and the final weight (after toothbrushing) using a Sartorius analytical scale. The evaluation of surface roughness was observed by the difference between initial and final means after 5 readings in a Hommel Tester T1000 testing machine. The specimens were also analysed by SEM. The obtained results (ANOVA and Tukey) showed significant differences of weight and surface roughness between the tested materials. SureFil and Alert exhibited lower loss of weight (Su-0.38%; A-0.52%), Solitaire, Prodigy Condensable, and Silux Plus presented greatest wear(So-1.51%; PC-1.55%, SP-1.70%) while Z100 and Filtek P-60 showed intermediate loss ( Z-1.16%; P-60-1.31%). Differently to the others groups, Prodigy Condensable, Solitaire and Z-100 showed a decrease in surface roughness compared to the initial condition (-0.012mm,-0.047mm and -0.065mm respectively) which increased in the remainder groups (A) 0.073mm, P-60) 0.095mm, Si) 0.158mm and Su) 0.470mm). SureFil presented the lowest weight loss and the highest surface roughness variation comparing to the other tested resins. There was no correlation between wear and surface roughness. The SEM results were in accordance to those obtained by the Hommel Tester T1000 testing machine. "condensable" composites resins showed the same behavior compared to the microhybrid Z100 control resin.
|
52 |
Estudo in vitro do efeito de unidades fotoativadoras com diferentes comprimentos de onda na dureza (por meio de micro e ultramicroendentação) e módulo de elasticidade de uma resina composta nanohíbrida / Effect of light sources with different wavelengths in micro and ultramicrohardness and elastic modulus of a nanohybrid composite resin. An in vitro studyAraujo, Jesuina Lamartine Nogueira 04 June 2013 (has links)
Este trabalho avaliou in vitro a dureza e módulo de elasticidade de uma resina composta nanohíbrida (Tetric N-Ceram/Ivoclair-Vivadent) com diferentes cores, fotoativada por duas unidades com diferentes comprimentos de onda em 3 espessuras (1, 2 e 3mm) comparadas à partir da superfície irradiada (0mm). Os espécimes foram divididos em grupos (n=5): microdureza Knoop-KHN, ultramicrodureza-DUH e módulo de elasticidade-ME, cor (A2 e Bleach-M(BM), fotoativador LEDazul (Elipar Freeligth2/3M(750mW/25s/430-480nm(FL) e LEDazul/violeta Bluephase/Ivoclar/Vivadent (1200mW/cm²/15s/380-515nm(B15) e 30s(B30). Os espécimes foram armazenados por 24h/37ºC. Os ensaios de KHN foram realizados no HMV-2000/Shimadzu, com carga de 25gf/40s, e de DUH e ME no DUH 211S/Shimadzu com força de 10mN e tempo de espera de 0s. Foram realizadas 5 endentações na superfície irradiada (0mm) e na base das amostras (1, 2 e 3mm). A análise estatística foi realizada por ANOVA, Tukey e correlação de Pearson (p<0,01%). O teste de Pearson mostrou haver correlação direta entre a KHN e a DUH. A fonte FL promoveu maiores valores de KHN e de DUH para as duas resinas testadas; enquanto que a fonte B15, promoveu o maior valor de ME. Quanto às espessuras, 0 e 1mm apresentaram maiores valores de KHN e de DUH, e menores de ME que as espessuras de 2 e 3mm. A cor A2 apresentou maior valor de KHN e DUH e menor ME que a cor Bleach-M. Assim, de acordo com a metodologia proposta e os resultados apresentados pode-se concluir que apesar de a luz LEDazul/violeta propor uma maior eficácia na polimerização de resinas de cor clara, no tocante às propriedades avaliadas isso não foi verificado. / This study evaluated in vitro the hardness (micro and ultramicro) and elastic modulus of a nanohybrid composite resin (Tetric N-Ceram/Ivoclar-Vivadent) with different colors, light sources and thickness. The specimens were divided into groups (n=5): KHN-Knoop microhardness, DUH-nanohardness and ME-elastic modulus; colors: A2 and Bleach-M (BM); light sources: LEDblue Elipar Free light 2/3M-ESPE (750mW/cm²/ 25s/430-480nm- (FL)), LEDblue/violet Bluephase/Ivoclar-Vivadent (1.200mw/cm²/15s/380-515nm) (B15) and 30s (B30); thickness: 1mm, 2mm and 3mm, compared to the irradiated surface (0mm). Specimens were stored dry for 24hours at 37ºC after photo curing. Assays were performed at KHN in HMV-2000/ Shimadzu with load of 25gf at 40s and DUH/ME in DUH 211S/Shimadzu with force of 10mN and no hold time (0s). 5 indentations of each test were made in the surfaces opposites to the photo curing. A statistical analysis was performed by ANOVA, Tukey and Pearson correlation (p<0.01%). Pearsons Test showed a direct correlation between KHN and DUH. Comparison between KHN and ME in the studied resins indicated that the light source FL promoted higher values of KHN and DUH to both resins tested, whereas the B15 light source promoted the higher ME value. Regarding thickness 0mm and 1mm showed higher KHN and DUH and lower ME than 2 and 3mm thickness. A2 color showed higher KHN and DUH and lower ME than BM. Thus, according to the proposed methods and the presented results, the LEDblue/violet was not better for curing the light color of the nanohybrid resin, than LEDblue.
|
53 |
Resistência adesiva dos cimentos resinosos convencionais e autoadesivos à dentina contaminada por saliva / Bond strength of different composite resin cements and dentin interfaces contaminated with salivaAcosta Servián, Victor Manuel 20 April 2012 (has links)
Muitas das lesões dentárias necessitam de restaurações indiretas que requerem cimentos adesivos para a sua fixação à estrutura dentária. Em algumas situações não é possível realizar o isolamento absoluto do campo operatório, o que pode levar à contaminação com saliva da dentina previamente aos procedimentos adesivos. Assim é necessário saber o nível de comprometimento da adesão em função deste fato. O presente estudo teve como objetivo analisar o tratamento da dentina contaminada com saliva na resistência adesiva dos cimentos resinosos convencional e autoadesivo através de testes de cisalhamento. Foram utilizados 50 incisivos bovinos que foram lixados até a exposição de dentina superficial e divididos em 6 grupos: Grupo ARC (controle): condicionamento ácido por 15s + sistema adesivo Scotchbond Multipurpose (3M/ESPE) + cimento RelyX ARC (3M/ESPE); Grupo ARClav: condicionamento ácido por 15s + contaminação com saliva + lavagem com água/ar 20 segundos + sistema adesivo + cimento RelyX ARC; Grupo ARCsec: condicionamento ácido por 15s + contaminação com saliva + secagem com papel absorvente + cimento autoadesivo RelyX ARC; Grupo ARCre: condicionamento ácido por 15s, contaminação + secagem jato de ar + recondicionamento por 15s + sistema adesivo Scotchbond Multipurpose + cimento RelyX ARC; Grupo U100 (controle): sem contaminação + cimento autoadesivo RelyX U100 (3M/ESPE); Grupo U100sec: contaminação + secagem jato de ar + cimento autoadesivo RelyX U100. Após a cimentação, os dentes foram armazenados em água destilada a 37ºC por 24 horas antes da realização do teste de cisalhamento. Os resultados obtidos foram submetidos à análise de variância a dois critérios e teste de Tukey com nível de significância de 5%. As médias gerais, dos grupos,expressas em MPa, foram G ARC: 9,02 ± 1,36 - G U100: 4,38 ± 0,74 - GARClav: 6,43 ± 0,98 GARCsec: 7,71 ± 1,14 GARCre: 5,68 ± 1,10 G U100sec: 3,87 ± 0,51. A análise dos resultados permitiu concluir que a adesão do cimento RelyX à dentina contaminada com saliva, lavada ou recondicionada com ácido fosfórico diminui significantemente quando comparada à adesão à dentina não contaminada ou àquela contaminada e apenas seca com papel absorvente. Já a contaminação com saliva não afetou significantemente a adesão do cimento RelyX U100 à dentina. / Many dental injuries require indirect restorations fixed by adhesive cements. In some situations is not possible to isolate the operative field, which can lead to contamination by saliva of the dentin. The aim of this study was to analyze the treatment of dentin contaminated with saliva on shear bond strength of conventional and self-adhesive resin cements. Fifty bovine incisors were ground until exposure of dentin surface and divided into six groups: Group ARC (control) no contamination + acid etch for 15s + Scotchbond Multipurpose system (3M/ESPE) + cement Rely X ARC (3M/ESPE); Group U100 (control): no contamination + self-adhesive cement RelyX U100 (3M/ESPE), Group ARClav: acid etch for 15s + saliva contamination + rising with water / air + adhesive system RelyX ARC, Group ARCsec: acid etch + contamination with saliva + drying with absorbent paper cement RelyX ARC, Group ARCre: acid etched, contamination with saliva + drying with absorbent paper + reetched for 15s + adhesive system Scotchbond Multipurpose + cement RelyX ARC, Group U100sec: contamination + drying with absorbent paper + self-adhesive cement RelyX U100. After cementation, the teeth were stored in distilled water at 37° C for 24 hours prior to shear testing. The results were analyzed by One-way ANOVA and Tukey\'sTests with a significance level of 5% were: G ARC: 9.02 ± 1.36 G U100: 4.38 ± 0.74 G ARClav: 6.43 ± 0.98 G ARCsec: 7.71 ± 1.14 G ARCre: 5, 68 ± 1.10 G U100sec: 3.87 ± 0.51.The results showed that there was a significant difference in bond strength of RelyX ARC to dentin contaminated by saliva when it was rinsed or re-etched, but there was no difference when the contaminated dentin was just dried with absorbent paper. No statistical difference was found between the adhesion resistance of the RelyX U100 to dentin with or without saliva contamination.
|
54 |
Ablação a laser de substratos dentais: esmalte,dentina e resinas compostas. / Laser Ablation of dental substrates: enamel, dentin and composite resins.Lizarelli, Rosane de Fátima Zanirato 14 November 2002 (has links)
O laser de alta intensidade é aceito atualmente como um instrumento satisfatório para remoção seletiva e precisa dos tecidos dentais cariados. Se corretamente usado, os lasers minimizam a perda de tecido sadio além de promoverem conforto aos pacientes. O conhecimento dos aspectos básicos da ablação a laser de tecidos dentais e materiais odontológicos pode conduzir ao desenvolvimento de um protocolo de parâmetros que possam permitir a remoção seletiva de tecidos cariados e resinas insatisfatórias preservando o tecido dental sadio. Os lasers de Nd:YAG, no regime de picossegundos, não estão ainda disponíveis para uso clínico odontológico. Sendo assim, estudos que permitam o máximo de informações relacionadas a esse sistema e ao órgão dental são bem-vindos, para estabelecer normas e parâmetros seguros para sua utilização, num futuro breve, na prática clínica. Três experimentos empregando o laser de Nd:YAG no regime de picossegundos foram executados: o mapeamento térmico, análise micromorfológica e cálculo da taxa de ablação, todos no nível de esmalte e de dentina, considerando como elementos-alvo, os dentes decíduos. O estudo de mapeamento térmico pôde determinar regiões de operação nas quais não ocorre um aquecimento deletério à polpa dental de dentes decíduos. Com relação aos aspectos micromorfológicos provenientes da interação laser-tecido de dentes decíduos, podemos observar os efeitos colaterais no nível de esmalte mais acentuados do que no nível da dentina. Enquanto a taxa de profundidade de penetração em dentina parece crescer com o progresso do tempo, para o esmalte o comportamento é oposto. O volume ablacionado de forma geral é mais alto em dentina quando comparado ao esmalte, o que resulta em uma taxa de ablação mais alta também. Com relação a remoção de tecidos cariados, o laser de Er:YAG já tem se mostrado como um instrumento seguro e muito eficiente, porém não se trata do único procedimento corriqueiramente realizado na clínica: a remoção ou modificação total ou parcial de restaurações de resinas compostas já polimerizadas tem se tornado uma das práticas mais executadas no dia-a-dia. Sendo assim, empregar esse laser com esse propósito inicia um estudo necessário para conhecermos os aspectos básicos resultantes da ablação a laser das resinas compostas. Os dois últimos experimentos, aqui apresentados, propuseram investigar a taxa de ablação e os aspectos micromorfológicos da ablação com o laser de Er:YAG dos tecidos duros dentais normalmente mais envolvidos em Dentística Restauradora, esmalte e dentina, provenientes tanto de dentes decíduos quanto de permanentes, e também de resinas compostas restauradoras fotopolimerizávies de três tipos: microparticulada, híbrida e compactável. Diferentes condições de trabalho foram utilizadas para analisar a real influência da ablação em resinas compostas com laser de Er:YAG: diferentes energias por pulso (100, 200, 300 e 400mJ) e tempos de imersão em água (zero, 4 e 7 dias). E os resultados nos permitiram concluir que o nível de energia por pulso foi o único fator que de fato pode influenciar a taxa de ablação. O tempo de imersão em água não influenciou de forma estatisticamente significante a taxa de ablação das resinas e os aspectos micromorfológicos resultantes se mostraram dependentes do tipo de estrutura e composição química diferente em cada resina composta aqui escolhida para ser estudada, bem como dos tecidos duros demais. Para finalizar, cruzando os dados obtidos nos dois últimos experimentos empregando o laser de Er:YAG, foi-nos possível encontrar parâmetros para uma ablação que, de fato, possa ser diferencial e seletiva para remoção exclusiva das resinas compostas. A técnica proposta parece ser muito satisfatória para o tecido esmalte, tanto para dentes decíduos quanto para dentes permanentes, enquanto que ainda para dentina não foi possível estabelecer parâmetros. Porém, investigando e entendendo os mecanismos envolvidos, um novo dado foi encontrado com relação a ablação a laser desses compósitos: a água parece não ser a mediadora na ablação pelo laser de Er:YAG, talvez então, esse achado possa agora contribuir para refinar os parâmetros seletivos, considerar o fator característica óptica do tecido-alvo e condições de irradiação, tais como, focalização e diâmetro do feixe laser e presença e quantidade de água no \"spray\", para esmalte e estabelecer aqueles para a dentina, tanto em relação aos dentes decíduos quanto aos permanentes. O objetivo principal foi alcançado, mostrando a viabilidade em preservar ainda mais estruturas de tecidos duros dentais sadios, tratando-os, de fato, e empregando instrumentos que interagem de formas diferenciadas, mostrando uma capacidade em identificar, segundo parâmetros aqui estabelecidos, o material que deva ser removido ou modificado sem resultar em danos colaterais prejudiciais ao órgão dental, e aos tecidos sadios que devem ser sempre conservados íntegros no meio bucal. / Laser is now established as a suitable tool for the selective and precise removal of carious dental tissue. If correctly used, lasers minimize the losses of healthy tissue besides the comfort that it ean promote to patients. The knowledge of basic aspects of laser ablation of dental tissues and materials can lead to the development of a set of parameters that may allow selective removable of deeayed tissues and dissatisfaetory resin preserving healthy dental tissue. Nd:YAG lasers in picosecond regime are not available to dentistry clinical uses yet. Because of that, studies able to allow much information related with this laser system and dental organ are welcome. It could establish safe parameters and rules to its utilization in a brief future in a clinical practice. Three experiments employing Nd: YAG picosecond pulsed laser were executed: thermal map out, micromorphological analysis and ablation rate calculation, all of them considering enamel and dentin, as target-tissues, and, from primary teeth. Thermal map out study resulted in safety operative regions where there are not detrimental heating to dental pulp of primary teeth. Considering micromorphological aspeets as result of laser-tissue interaction in primary teeth, we could observe that collateral damage at the level of enamel more evident than in dentin. While the rate of penetration depth in dentin seems to scale up as the time progress, for enamel the behavior is the opposite. The overall ablated volume is higher in dentin when compared to enamel, which results in a higher ablated rate as well. With relation to decayed tissues, Er: YAG laser has been well established as an efficient and safety tool, however it is not an unique common clinical procedure everyday in offices, total or partial removal or modification of composite resins restorations have became one clinical practice priority. In this manner, to employ this laser system to this proposal seems adequate and starts a necessary research to understand the basic features of laser ablation of composite resin. The last two experiments, presented here, have purposed to investigate ablation rate and micromorphological aspects when dental hard tissues, enamel and dentin, from primary and permanent teeth, are irradiated by Er: YAG laser, besides, photo curable restorative composite resins of three kind of type were irradiated toa: microfiller, hybrid and condensable. Different conditions of work were used to evaluate the real influence of composite resins ablation with Er:YAG laser under different energies per pulse (100, 200, 300 and 400mJ) and immersion time in distilled water (zero, 4 and 7 days). The results allowed concluding that the unique variable factor able to influence statistically the ablation rate of composite was the energy per pulse. The immersion time in water did not influence statistically the ablation rate of resins and the resulted micromorphological aspects showed a dependence considering structure type and chemical composition; they are different to each kind of choose composite studied here, it seems occur even with dental hard tissues. To conclude, combining obtained data from the two cited above experiments with Er:YAG laser, it was possible found parameters to result in a differential and selective ablation, removing exclusively composite resins. The proposed technique seems to be much adequate, however while this idea seems to apply well for enamel of primary and pennanent teeth at the present stage it does not apply well for primary or pennanent dentin. For dentin, the composition and content of water makes the Er: YAG laser ablation equal as superior in rate compared in the three used resins. After understanding the resulted interactions between lasers and substrates, there is an interesting suggestion to search for a more convenient laser system to ablate composite resin. Also, the overall shape of ablation rate indicates that the water flux may well be an important variable to be investigating on the ablation rates. Maybe, like this, this finding could contribute to refine the selective parameters to prevent the useless ablation of enamel and dentin from primary and permanent teeth.
|
55 |
"Estudo da influência do tratamento por calor em propriedades mecânicas de resinas compostas" / Influence of heat treatment on the mechanical properties of resin compositesSantana, Ivone Lima 08 December 2005 (has links)
O objetivo deste trabalho foi o de avaliar o efeito de tratamentos por calor nas propriedades mecânicas de resistência flexional e microdureza Knoop de três marcas comerciais de resinas compostas para uso direto (FillMagic, P60 e TPH), na condição de incluída ou não em revestimento durante um tratamento térmico (calor seco/170°C), por três períodos (5, 10 e 15 min). A temperatura adotada para os tratamentos foi baseada em análises prévias (termogravimetria e calorimetria exploratória diferencial) com a finalidade de se determinar a temperatura de início de perda de massa e de transição vítrea das resinas. Os corpos-de-prova (n=7) foram confeccionados com o auxílio de uma matriz metálica (10 mm x 2 mm x 2 mm), sendo o compósito inserido em bloco único e irradiado numa única superfície (600mW/cm 2 por 40s). Foram obtidos, no total, sete grupos experimentais por resina, sendo o controle a condição de apenas fotoativada. Os espécimes foram submetidos ao ensaio de resistência à flexão, com distância entre apoios de 8 mm, em uma velocidade constante de 0,5 mm/min e célula de carga de 1000N. A dureza Knoop foi obtida com carga de 100 g e tempo de penetração de 15 s. As médias de resistência flexional, em MPa, foram de 174,80 para a resina FillMagic, 182,64 para a P60 e 172,22 para a TPH. Na mesma ordem, as médias de microdureza Knoop foram de 73,1; 102,0 e 74,0.A análise de variância dos resultados obtidos permitiram concluir que os tratamentos experimentais aumentaram a resistência flexional das resinas indistintamente. Os valores de microdureza também aumentaram, mas houveram diferenças de suscetibilidade ao tratamento térmico entre as resinas / The aim of this study was to assess the effect of heat treatment on mechanical properties of flexure strength and Knoop micro hardness of three commercially available brands of resin composites for direct use (FillMagic, P60 and TPH) included or not in investments during heat treatment (dry heat/170ºC) by three periods (5, 10 and 15 min.) The temperature adopted for the treatments was based on previous analysis (thermo gravimetric and differential exploratory heating) in order to determine the initial temperature of mass loss and glass transition of resin composites. The samples (n=7) were prepared with a metallic matrix (10 mm x 2mm x 2mm) in which the resin composite was inserted in a single block and only one surface was irradiated (600mW/cm 2 40s). Seven experimental groups were obtained for each resin composite in which the control group was solely light-cured. The flexure strength test was performed with a support distance of 8 mm, cross-head speed of 0.5 mm/min. and 1000 N load. Knoop micro hardness was obtained with a load of 100 g and penetration time of 15 s. The flexure strength averages in MPa were 174.80 for FillMagic, 182. 64 for P60 and 172. 22 for TPH. Thus, Knoop micro hardness means were 73.1; 102.0 and 74.0. The analysis of variance indicated that the experimental treatments increased flexure strength of resin composites. Micro hardness values also increased, but there were differences in the resin composites susceptibility to the heat treatment
|
56 |
INFLUÊNCIA DA INCORPORAÇÃO DE UM PLASTIFICANTE E UM POLIETILENO DE ALTO PESO MOLECULAR NAS PROPRIEDADES DE UMA RESINA EXPERIMENTAL E DIMINUIÇÃO DO ESTRESSE DE CONTRAÇÃO / Influence of the incorporation of a plasticizer and high molecular weight polyethylene on the properties of an experimental resin and shrinkage stress decrease.Dominguez, John Alexis 13 August 2015 (has links)
Made available in DSpace on 2017-07-24T19:22:03Z (GMT). No. of bitstreams: 1
John Alexis Domingues.pdf: 1971333 bytes, checksum: 6d76db539da045af70dd08f004b5c7c8 (MD5)
Previous issue date: 2015-08-13 / The objectives of this study were: 1) to evaluate the degree of conversion, shrinkage stress, flexural and compressive strength of an experimental resin with a lactic polyacid and castor oil; 2) to evaluate the cytotoxicity of an experimental resin with a lactic polyacid, and castor oil; 3) evaluate, degree of conversion,
shrinkage stress, flexural and compressive strength an experimental resin with addition of a high molecular weight polyethylene; 4) to assess the cytotoxicity of an experimental resin with addition of a high molecular weight polyethylene.
Initially, it was synthesized a poly (lactic acid) (PLA) via a polycondensation process. After 24 hours, the castor oil (OR) was incorporated by an esterification process with N, N-Dicyclonecylcarbodimide and 99% 4-Dimethylamino-Pyridine
in 40 mL of tetrahydrofuran. After this, the blend was characterized by X-ray diffraction (XRPD), Raman spectroscopy, scanning electron microscopy (SEM) and shrinkage stress, where was proven the incorporation of PLA + OR in the experimental composite resin. In the third chapter, PLA + OR were manipulated
in two concentrations (1.5% and 3%) in an experimental composite: (2,2 bis [4- (2-hydroxy-3-metacrilatoxypropoxy) phenol] (BisGMA) Triethylene glycol dimethacrylate (TEGDMA), camphorquinone (CQ), N, N-dimethylaminoethyl
methacrylate (DEMA-EMA), butylated hydroxytoluene (BHT), silanated barium borosilicate glass, and the tests of degree of conversion, compressive and flexural strength and shrinkage stress were made. The cytotoxicity assay was done; a suspension of 3 x 103 cells/mL of culture medium was prepared. For this, the cells were detached from the bottom of the bottle by the addition of trypsin with EDTA, after incubation in 5% CO2 with 3 mL Eagle's medium supplemented culture. After 24 h incubation period, the culture medium was removed and 200
uL of a solution of culture medium and methylltetrazolium salt (MTT). Subsequently, the analysis of mitochondrial activity was performed in a spectrophotometer (Biotek EL 800, Biotek, Winooski, VT, USA) with a 10 wavelength of 570 nm. The data from each test were analyzed by one-way ANOVA. No significant differences were found (p <0.005) in compressive and
degree of conversion tests, and significant differences in shrinkage stress where obtained, up to 69% decrease. and flexion, statistically significant . In the fourth chapter, it was incorporated a high molecular weight polyethylene and
polypropiylene, in the experimental resin proposed in chapter two, at two concentrations (1.5% and 3%), and tested by degree of conversion, compressive and flexural strength and shrinkage stress. The data from each test were analyzed by one way ANOVA, finding no significant difference (p> 0.005) in
degree of conversion, compressive and flexural strength, and the contraction stress showed a significant reduction of up to 40%. Conclusion: PLA + castor oil and the high molecular weight polyethylene decreases the shrinkage stress and properties like flexural and compressive strength and degree of conversion were not influenced. / Os objetivos deste estudo foram: 1) avaliar o grau de conversão, tensão de contração, resistência à flexão e compressão de uma resina experimental com um poliácido lático e óleo de rícino; 2) avaliar a citotoxicidade de uma resina
experimental com um poliácido lático e óleo de rícino; 3) avaliar o grau de conversão, tensão de contração, resistência à flexão e compressão de uma resina experimental com adição de um polietileno de alto peso molecular e 4) avaliar a citotoxicidade de uma resina experimental com adição de um polietileno de alto peso molecular. Previamente realizou-se a síntese de um Poli-ácido lático (PLA) por meio de um processo de policondensação. Após 24 horas, foi incorporado o óleo de rícino (OR) por meio de um processo de esterificação junto
a N,N-Diciclonecilcarbodimida e 4-Dimetilamino-Piridina a 99% em 40 mL de tetrahidrofeurano. Em seguida, o conjunto foi caracterizado por difração de espectroscopia Raman, microscopia eletrônica de varredura (MEV) e estresse
de contração, onde foi comprovada a incorporação do PLA+OR numa resina composta experimental. No terceiro capítulo foi feita a incorporação do PLA+OR em duas concentrações (1,5% e 3%) numa resina composta experimental: (2,2 bis[4-(2-hidroxi-3-metacrilatoxipropoxi)fenol](BisGMA), Trietilglicoldimetacrilato
(TEGDMA), canforoquinona (CQ), N,N– dimetilaminoetil metacrilato (DMAEMA), hidroxitolueno butilado (BHT), vidro de borossilicato de bário silanizado e foram realizados os testes de flexão, compressão, grau de conversão e estresse
de contração. Foi feito o teste de citotoxicidade, uma suspensão de 3 x 103 células/mL de meio de cultura foi preparada. Para isso, as células foram descoladas do fundo da garrafa por meio da adição de tripsina com EDTA, após incubação em estufa com 5% de CO2 e 3 mL de meio de cultura Eagle suplementado. Após o período de incubação de 24 h, o meio de cultura foi
removido e 200 μL de uma solução de meio de cultura e sal metiltetrazólio (MTT).Posteriormente, a análise da atividade mitocondrial foi realizada em espectrofotômetro (Biotek EL 800, Biotek, Winooski, VT, EUA) com comprimento
de onda de 570 nm. Os dados obtidos de cada teste foram analisados com ANOVA um fator. Não encontrou-se diferença significativa (p> 0.005) nos testes de compressão e grau de conversão; já para o teste de estresse de contração,
houve diminuição estatisticamente significativa de até 69% e no teste de resistência à flexão . No quarto capítulo foi feita a incorporação de um polipropileno (PP) e o polietileno de ultra-alto peso molecular (UTEC) a uma resina experimental com os mesmos materiais manipulados no capítulo dois, em
duas concentrações (1,5% e 3%), e realizados os testes de compressão, flexão, grau de conversão e estresse de contração. Os dados de cada teste foram analisados com ANOVA um fator. Não houve diferença significativa (p> 0.005) nos testes de compressão, flexão e grau de conversão; já para o teste de
estresse de contração houve diminuição estatisticamente significativa de até 40%. Conclusão: OPLA+óleo de rícino e o polietileno de ultra alto peso molecular em 1,5%, diminuíram o estresse de contração e propriedades como resistência à flexão, compressão e grau de conversão não foram influenciadas.
|
57 |
Avaliação espectrofotométrica da estabilidade de cor de materiais restauradores estéticosSamra, Adriana Postiglione Bührer 22 July 2004 (has links)
Made available in DSpace on 2017-07-24T19:22:23Z (GMT). No. of bitstreams: 1
AdrianaPostiglione.pdf: 1074589 bytes, checksum: ebd4e6efb3931ba759be23147fe7f4b2 (MD5)
Previous issue date: 2004-07-22 / Color match is one of the most important characteristics of the aesthetics restorative materials. Color stability is a demanding characteristic of the restorative
material as though as it indicates its chemical stability. The purpose of this research is to verify the color stability of five aesthetic restorative materials when immersed in coffee solution and the efficiency of professional prophylaxis on pigmentation
reduction after the staining. There were built 71 specimens, divided in five groups,made of one direct composite resin (Tetric Ceram – Ivoclar/Vivadent – G1), three indirect composite resins (Targis – voclar/Vivadent – G2; Resilab Master – Wilcos – G3; belleGlass HP – Kerr – G4) and one porcelain (IPS Empress 2 – Ivoclar/Vivadent – G5), with the dimensions of 17 mm x 1mm. The specimens were
immersed in staining media of coffee for 15 days, stored in controlled temperature of 37±1C at dark. In the sequency, they received a professional prophylaxis with
sodium bicarbonate. The evaluations were made after 1, 7 e 15 days and after the prophylaxis, by means of reflectance spectrophotometry. Data were submitted to two-way ANOVA (p<0,001) and post-hoc tests with estathistical difference between G1 / G3 and the other groups; G2 / G4 and the other groups; and G5 and all the others. It was concluded that G1 e G3 showed the greatest color changes, lollowed
by G2 and G4 and G5 showed the smallest changes. Professional prophylaxis was efficient to reduce the staining for all the materials tested. / A estabilidade de cor é indispensável para a durabilidade do tratamento restaurador estético. O objetivo deste trabalho é verificar a estabilidade de cor de cinco materiais restauradores submetidos a meio corante de café e a eficácia da profilaxia em reduzir a pigmentação decorrente do meio corante. Foram confeccionados 71 corpos-de-prova, divididos em cinco grupos (G1- resina composta Tetric Ceram – Ivoclar/Vivadent , G2, G3 e G4- resinas laboratoriais de
segunda geração, respectivamente Targis – Ivoclar/Vivadent; Resilab Máster – Wilcos; belleGlass HP – Kerr e G5- porcelana IPS Empress 2 – Ivoclar/vivadent) , com 17 mm de diâmetro por 1 mm de espessura. Os corpos-de-prova foram
mantidos imersos em solução de café por 15 dias, em estufa com temperatura controlada de 37± 1 C ao abrigo da luz. Na seqüência, foram submetidos a profilaxia com bicarbonato de sódio. As avaliações foram realizadas depois de 1, 7 e
15 dias e após profilaxia, por espectrofotometria de reflectância. A variável E foi avaliada em relação aos fatores período experimental e tempo, utilizando-se teste ANOVA a dois critérios (p<0,001). Ao se proceder aos testes pot-hoc constatou-se diferenças significativas entre G1 e G3 e os demais, entre G2 e G4 e os demais e entre G5 e todos os restantes. Concluiu-se que G1 e G3 apresentaram as maiores
alterações de cor, enquanto que G2 e G4, postos intermediários e G5, apresentou a menor alteração, que foi mais intensa nos períodos de 1 dia e 7 dias para todos os
materiais. A profilaxia foi eficiente para reduzir a alteração de cor.
|
58 |
Avaliação da microdureza superficial de resinas compostas extraclaras fotopolimerizadas por luz halógenas e LEDs. descrição das caracteristícas dos aparelhos fotopomerizadoresCotrina, Leyla Antoinette Delgado 23 July 2004 (has links)
Made available in DSpace on 2017-07-24T19:22:27Z (GMT). No. of bitstreams: 1
Leyla Antoinette Delgado Cotrina.pdf: 1205647 bytes, checksum: 64a5a6bbc08abd8e9aef28e74483da56 (MD5)
Previous issue date: 2004-07-23 / DELGADO, L. Evaluation of the superficial microhardness of extra-light
composite resins photocured by Halogen Light and LEDs. Description the
characteristics of the light sources. Ponta Grossa, 2004. 129 Dissertação
(Mestrado em Clínica Integrada) – Faculdade de Odontologia, Universidade Estadual
de Ponta Grossa.
The purpose of this study was to evaluate the superficial microhardness of four extralight
microhibrid composite resins photocured with different types of light curing units:
Halogen and LEDs. The emission spectrum (nm) and power (mW) of the curing units
were tested using the spectrometer USB2000 (Ocean Optics) and the Power Meter
(Ophir). The light intensity (mW/cm2) was determined through the value of power and
area the light guide of each unit (i=P/A). The resins and colors used were: Tetric®
Ceram (Ivoclar Vivadent) A2 and XL; FiltekTM Z250 (3M-ESPE) A2 and B0.5;
Charisma® (Heraeus Kulzer) A2 and SL; and Esthet X (Dentsply) A2 and XL. The
curing units used were: Curing Light 2500 (3M-ESPE) and Elipar® FreeLight (3MESPE).
Metallic matrixes were made with a hole of 5mm diameter and 2 mm thick.
Samples of the resins were made on these matrixes and were marked and storaged
in dry, dark jars for 24 hours. After this, the samples were evaluated using Vickers
microhardness test through the digital microhardmeter MMT-3 (Buehler) with 50 gf
charge for 30 seconds. Data collected was analyzed with a mutlifactorial variance
and Tukey tests. T-test was used on paired samples to determine significant
difference between surfaces. Also was calculated the percentage of depth of cure.
Results showed that the emission spectrum of the LED curing unit was more reduced
than the halogen curing unit (430–520nm and 400-520nm respectively).
Nevertheless, the halogen curing unit presented a greater power and intensity of
light. The factors analyzed (type of resin, color and light source) influenced the
microhardness values. It was found that the extra-light color resins presented the
least values of microhardness independent to the light source. The LEDs curing units
presented the least values of superficial microhardness. The Tetric® Ceram XL resin
composite showed percentage of depth of cure less 80%, independent to the light
source. The same occurred with A2 and XL colors the Charisma® resin composite
when cured with LEDs unit. / DELGADO, L. Avaliação da microdureza superficial de resinas compostas
extraclaras fotopolimerizadas por luz halógena e LEDs. Descrição das
características dos aparelhos fotopolimerizadores. Ponta Grossa, 2004. 129.
Dissertação (Mestrado em Clínica Integrada) – Faculdade de Odontologia,
Universidade Estadual de Ponta Grossa.
O objetivo deste trabalho foi avaliar a microdureza superficial de quatro resinas
compostas microhíbridas de cor extraclara quando fotopolimerizadas com duas
fontes de luz: halógena e LEDs. Paralelamente determinou-se o espectro de
emissão (nm) e a potência (W) dos aparelhos testados através do espectrômetro
USB2000 (Ocean Optics) e o Power Meter (Ophir) respectivamente. A intensidade
de luz (mW/cm2) foi calculada através do valor da potência e da área da ponta ativa
de cada aparelho (i=P/A). As resinas compostas utilizadas foram: Tetric® Ceram
(Ivoclar Vivadent) A2 e XL, FiltekTM Z250 (3M-ESPE) A2 e B0.5, Charisma® (Heraeus
Kulzer) A2 e SL e Esthet X (Dentsply) A2 e XL. Os aparelhos utilizados foram o
aparelho Curing Light 2500 (3M-ESPE) e Elipar® FreeLight (3M-ESPE). Para a
confecção dos corpos-de-prova foram utilizadas matrizes metálicas que com orifício
central de 5 mm de diâmetro por 2 mm de espessura. Os corpos-de-prova foram
identificados e armazenados em recipientes secos e ao abrigo da luz durante 24
horas. Passado este tempo, foram submetidos ao teste de microdureza Vickers
através do microdurômetro digital MMT-3 (Buehler) com carga de 50 gf durante 30
segundos. Os valores de microdureza foram analisados através da análise de
variância multifatorial e teste de Tukey. O teste t para amostras pareadas foi utilizado
para determinar diferenças entre as superfícies. Também foi calculada a
porcentagem de profundidade de polimerização. Os resultados evidenciaram que o
espectro de emissão do aparelho à base de LEDs é mais estreito do que do
aparelho de luz halógena, sendo que este último apresentou maior potência e maior
intensidade de luz. Os fatores analisados (resina composta, cor e fonte de luz)
influenciaram nos valores de microdureza. Concluiu-se que a cor extraclara obteve
os menores valores de microdureza independentemente do tipo de fonte de luz
utilizada e o aparelho à base de LEDs proporcionou os valores mais baixos de
microdureza superficial. A resina composta Tetric® Ceram cor XL atingiu
porcentagem de polimerização inferior a 80%, independentemente do tipo de fonte
utilizada. As cores A2 e XL da resina composta Charisma® não obtiveram
porcentagens de profundidade de polimerização acima de 80% quando
fotopolimerizada com o aparelho à base de LEDs.
|
59 |
Efeito da concentração de argila nas propriedades termomecânicas de uma resina dentária modelo / Effects of organoclay loadings on the thermal mechanical properties of a model dental resinTerrin, Marina Martins 18 October 2013 (has links)
Apesar dos vários avanços que levaram à expansão do uso de compósitos dentários, ainda há deficiências que limitam suas aplicações. A resistência inadequada ao desgaste mastigatório é constantemente citada como problema das resinas e que acaba tornando-se responsável parcialmente pela redução de sua vida útil. O desgaste do material ocorre pela perda ou degradação da matriz orgânica permitindo a exposição da matriz inorgânica e consequentemente levando a perda desta. Sendo assim, o presente trabalho tem como objetivo principal avaliar o efeito das diferentes concentrações de argila organofílica nas propriedades de uma resina dentária modelo. Primeiramente, foi realizada a purificação da argila e sua posterior troca iônica, o preparo das resinas experimentais e posterior adição de argila em diferentes concentrações, e finalmente a confecção dos corpos de prova. Então, as resinas foram avaliadas através de técnicas como o DMA, TGA, PCA, FTIR, DRX e por testes de inchamento para avaliar a absorção de água. Por FTIR e por PCA foi possível realizar o acompanhamento da cinética de reação das resinas preparadas, obtendo-se assim o seu grau de conversão e também uma análise da sua cinética de polimerização, sendo observado que em concentrações maiores de argila, o grau de conversão e a taxa de polimerização diminuíram. Por TGA foi possível observar dois picos no segundo processo de degradação térmica da amostra sem adição de argila, indicando uma polimerização não homogênea; conforme aumenta-se a quantidade de argila presente na mistura, os picos duplos tornam-se um. DMA mostrou discreto aumento da Tg e aumento de E\' e E\", indicando um reforço destes compósitos. DRX mostrou que não houve exfoliação da argila no polímero, podendo ter a formação de um compósito convencional ou de um compósito intercalado sem expansão do espaço interlamelar. Já os testes de inchamento mostraram que quanto maior o teor de argila maior a absorção de água das resinas. / In spite of the developments that led to the use of dental composites, there are still some shortcomings that limit their use. Inadequate resistance due to the mastigatory wearing is often cited as an issue in resins, which is partially responsible for reducing its lifetime. Wearing out of the material occurs by the loss or degradation of the organic matrix, thus allowing the inorganic matrix to become exposed and consequently leading to its loss. Therefore, the present work has as main goal the evaluation of the effect of different organoclay filler content in the properties of a experimental dental resin. For such, the clay was first purified and then underwent through cationic exchange, following preparation of the resins and later addition of the organoclay obtained and preparing the specimens. The, the resins were evaluated by techniques such as DMA, TGA, PCA, DRX and swelling tests to observe water sorption. By FTIR and PCA it was possible to follow the reaction kinectics of the prepared resins, thus obtaining the degree of convertion and polymerization rate, allowing to observe that the higher the organoclay loadings the lower was both the polymerization rate and the degree of convertion. TGA allowed us to observe two peaks on the second process of thermal degradation on the sample with no clay, thus indicating a non-homogeneous polymerization; and with higher clay loadings the double peaks become one single peak. DMA showed a slight increase of Tg and also an increase in E\' and E\", indicating a reinforcement of the obtained composites. DRX showed no exfoliation of the polymer, thus forming either a conventional composite or maybe a interlacated composite with no expansion of the interlamelar space. Swelling tests showed that the higher the amount of organoclay added the higher was the amount of water absorbed by the specimens.
|
60 |
Avaliação da influência do material de confecção das matrizes no teste de conversão monomérica por espectrometria no infravermelho de um compósito / Evaluation of the influence of the mould material on the degree of conversion by infrared spectroscopy of a compositeAdriana Riedlinger Mont'Alverne Bordalo 18 December 2007 (has links)
Este estudo teve por objetivo avaliar, in vitro, a influência do material de confecção das matrizes, traçando um perfil da conversão monomérica de um compósito micro-híbrido, além de avaliar qual dos materiais testados mais se assemelha a uma matriz de dentina. A avaliação foi feita através da análise do grau de conversão (GC). Foram confeccionadas 3 matrizes bipartidas, sendo estas de teflon negro, tefon branco e aço inoxidável, ambas com 10mm de diâmetro e 2 mm de profundidade. Para o grupo controle foi utilizado um incisivo central bovino, o qual teve sua face vestibular aplainada em uma lixadeira sob refrigeração constante, com o auxílio de uma lixa de carbeto de silício, número 800. Após, este dente foi preparado com uma broca diamantada número 2294 (KG Sorensen) em alta rotação, própria para a preparação de cavidades padronizadas para ensaios de laboratório, apresentando um limitador de penetração. Em seguida, com um motor de baixa rotação foi realizado o acabamento das paredes, obtendo-se uma cavidade de 2,0 mm de profundidade por 9,0 mm de diâmetro. Pela palatina desse dente, com uma broca carbide cilíndrica de numeração 2056 (KG Sorensen), fez-se uma penetração até se obter uma parede de dentina extremamente fina, porém sem que esta fosse rompida. Assim, com uma agulha, fez-se uma pequena perfuração no centro dessa dentina para que este instrumental servisse como um pino para remoção do corpo de prova de dentro da matriz de dente. Os corpos de prova (CP) foram obtidos a partir da inserção do compósito no interior da perfuração das matrizes em um único incremento e cobertos na superfície externa com uma matriz de poliéster mais uma lamínula de vidro. Os CP foram fotopolimerizados por 40 s pela fonte de luz halógena Optilux 501 (Demetron), com 500 mW/cm. Imediatamente após a polimerização, os corpos de prova eram submetidos no topo e na base para a análise de espectrometria no infravermelho para a determinação da profundidade de polimerização, pela técnica do filme vazado para o compósito não polimerizado e pela técnica da pastilha de brometo de potássio (KBr) para o compósito polimerizado. Foram confeccionados 5 CP de cada grupo. Em cada grupo, o compósito da base e do topo das amostras foi moído até se obter de 1,5 a 2,0 mg de pó e misturado com 70 mg de KBr, para obtenção da pastilha de KBr. Foi feita a análise de espectrofotometria no infravermelho por Transformada de Fourier (FTIR). As absorções selecionadas para o cálculo foram 1610 cm-1 e 1637 cm-1, os picos dos espectros das ligações dos carbonos aromáticos e alifáticos, respectivamente. Os dados obtidos foram tratados estatisticamente. Os grupos Gr1B, Gr2B, Gr3B e Gr4B representam, respectivamente, as bases dos CP confeccionados pelas matrizes de DB, TN, TB e AI. Já os Gr1T, Gr2T, Gr3T e Gr4T representam os topos. Médias (%) e DP: Gr1T (46,461,99), Gr2T (39,864,51), Gr3T (44,053,44) e Gr4T (38,045,08). Gr1B (40,441,49), Gr2B (36,153,81), Gr3B (40,093,18) e Gr4B (35,593,35). Em posse dos resultados, pôde-se concluir que os grupos do teflon negro, teflon branco e aço inoxidável não apresentaram diferenças entre o grau de conversão do topo e da base, enquanto que o grupo da dentina apresentou maior conversão do topo. Comparando as matrizes entre elas, pôde-se perceber que no topo, o GC do dente bovino é maior que o GC do aço inoxidável e do que o de teflon negro, o GC do teflon branco é maior que o GC do aço inoxidável e do que o de teflon negro. Já o topo dos grupos de dente bovino e teflon banco foram semelhantes. Nas bases dos CPs, não houve diferença significativa entre os grupos testados. De acordo com os resultados obtidos no experimento, pôde-se concluir que nos grupos do teflon negro, teflon branco e aço inoxidável não houve diferença entre 0 e 2 mm, ou seja, topo e base, o que mostra que o material de confecção da matriz não influênciou o grau de conversão do compósito. Já para o grupo da matriz de dentina, o topo apresentou valor de conversão monomérica maior, mostrando que, neste caso, o material da matriz interferiu no grau de conversão. Pode-se perceber também que existe uma tendência da matriz de teflon branco se assemelhar mais a matriz de dentina, pois foi o único grupo que apresentou semelhança nos valores de conversão monomérica no topo das amostras. Porém analisando a base das amostras, percebe-se que todos os grupos se comportaram de forma semelhante, obtendo valores do grau de conversão sem diferença significante. / This study was undertaken in order to determine, in vitro, the influence of mould material by the degree of conversion in a composite, and assess which of the materials tested was more akin to an array of dentin. The assessment was made by examining the degree of conversion (DC). Three bipartite moulds were made of black Teflon, white Teflon and stainless steel. All of them had 10 mm of diameter and 2 mm of deep. To the control group it was used a bovine central incisor, which had its buccal face leveled off in a sander under refrigeration with help of sandpaper 800. After that, this tooth was prepared in high speed with a diamond bur 2294 (KG Sorensen). This bur is proper for preparing standardized cavities for laboratories tests, and has a flat end with stop. A cavity of 2 mm of deep for 9 mm of diameter was obtained by a low speed that made the walls finished. With a cylindrical carbide bur 2056 (KG Sorensen), through the tooth lingual, a penetration was made until an extremely thin wall of dentin was obtained. Thus, with a needle, a little perforation was made in the center of this dentin. The specimens were made dispensed the restorative material on a single increment. A strip of cellulose was placed on top and a glass slab was pressed on the top. The material was cured during 40 seconds by halogen light, Optilux 501 (Demetron), with 500 mW/cm. Immediately, after cured, the specimens were submitted, on the top and on the bottom, to analyze their degree of conversion by FTIR. For the uncured composite was used the technique of the film leaked and for the cured composite, the technique of the potassium bromide tablet (KBr). Five specimens of each group had been confectioned. In each group, the bottom and top composite of the samples was worn out until if getting of 1,5 the 2,0 mg of dust and mixed with 70 mg of KBr, for attainment of the tablet of KBr. The analysis of FTIR was made. The absorptions selected for the calculation had been 1610 cm-1 and 1637 cm-1, the peaks of the specters of the linkings of aromatical and alifatic carbons, respectively. The data had been treated statistical. It could be concluded that the groups of black Teflon, white Teflon and stainless steel had not presented differences between the degree of conversion of the top and the bottom, whereas the group of the dentin presented greater conversion of the top. Comparing the moulds between them, it could be noticed that in the top, the DC of the bovine tooth is greater that the DC of the stainless steel and black Teflon, the DC of white Teflon is greater that the DC of the stainless steel and black Teflon. The top of the groups of bovine tooth and black teflon been similar. In the bottoms of the specimens, it did not have significant difference between the tested groups. In accordance with the results gotten in the experiment, could be concluded that in the groups of black Teflon, white Teflon and stainless steel it did not have difference between 0 and 2 mm, that is, top and bottom, its means that the material of mould confection did not influence the degree of conversion of the composite. Already for the group of the dentin, the top presented value of bigger conversion, showing that, in this in case that, the material of the matrix intervened with the DC. It can also be perceived that a trend of the white Teflon mould to resemble more the dentin mould, therefore was the only group that presented similarity in the values of DC in the top of the samples. However analyzing the bottom of the samples, all the groups had values of the degree of conversion without significant difference.
|
Page generated in 0.124 seconds